Hex-A-Gone™ 1020 is a decorative trivalent chromium
electroplating system which produces a finish comparable in
color to a hexavalent chromium deposit. Hex-A-Gone™ 1020
offers exceptional throwing power, ease of operation, and good
tolerance to metallic impurities. Trivalent chromium plating
solutions offer reduced waste treatment costs and less health
and environmental concerns than hexavalent chromium
solutions.
• Exceptional throwing power with bright deposits at
thicknesses up to 20 microinches (0.5 microns)
• Environmentally friendly - Contains no carcinogenic
hexavalent chromium
• Higher bath efficiency produces plating rates of 2-3
microinches per minute (0.05-0.08 µm/minute)
• Improved throwing power compared to hexavalent chrome
plating allows for 30-50% increase in rack density
• Deposit color is similar to hexavalent chromium deposits
• Hexavalent Chromium-free
• Reduced energy consumption
Plating System
Hex-A-Gone™ 1020
2
Plating System Hex-A-Gone™ 1020
Operating Parameters:
Range Optimum
Total Chromium:
(use “High Efficiency” for high thickness
applications)
6 - 13 g/L 9.5 g/L (High Efficiency)
7 g/L (General Purpose)
Hex-A-Gone™ Salts: 35 - 39 oz/gal
260 - 290 g/L
37.3 oz/gal
280 g/L
Hex-A-Gone™ Cr Maint.: 8.8 - 16.3% 12.5%
Surface Tension: 25 - 35 dynes/cm 30 dynes/cm
Cathode Current Density: 50 - 90 ASF
(5.4 – 9.7 ASD)
70 ASF
(7.5 ASD)
Anode Current Density:
pH:
20-50 ASF
(2.2-5.4 ASD)
3.2 - 3.6
3.6
Temperature: 120° - 140°F
(49° - 60˚C)
125°F
(52°C)
Specific Gravity 1.20 - 1.25 1.225
Equipment:
Tank: A polypropylene, PVC, or Koroseal lined tank.
Anodes: Inert anodes with special catalytic coatings are used for direct contact
with plating solution. Pavco recommends installing a plastic mesh over
the anodes to prevent scratching or mechanically damaging the catalytic
coating. Contact Pavco representative for sourcing. USE ONLY PAVCO
QUALIFIED ANODE SOURCES.
Anode Bars: Use copper anode bars, preferably shielded with plastic.
pH meter: Careful control of pH is critical to the successful operation of Hex-A-Gone™
1020. A good pH probe and frequent standardization of the meter are
necessary.
Filtration: Use 5 - 15 micron polypropylene filters and activated carbon.
Filtration rate should be at least 1 tank turnover per hour.
Rectifier: Up to 12 volts, less than 5% ripple.
Temperature Control: A titanium heat exchanger is recommended.
Ventilation: Required, check local regulations
Agitation: Air agitation is required for dissolution of salt additions. Air agitation is
optional when electroplating. If air is used, it should be light and uniform.
Slow mechanical agitation with a moving cathode rod produces the most
optimal results.
Metallic Removal: Effective contaminant removal is critical to maintaining consistent deposit
color. Continuous contaminant removal is recommended by continuous
dummy cell (10% of tank volume) or ion exchange. Consult a Pavco
representative for recommendations on dummy cell design or Premier IX
Resin ion exchange resin system.
3
Plating System Hex-A-Gone™ 1020
Bath Maintenance:
Hex-A-Gone™ Cr Maint.: 1 gal/4,000-8,000 amp-hrs. (475-870 mL/1,000 amp-hrs(KAH))
Rate varies with cathode efficiency. Adjust feed rate based on chrome
metal concentration. Continuous, regular additions are required, even
during dummy electrolysis.
DecoTri MS:
1 gal/ 25,000 amp-hrs. (150 mL/KAH)
Hex-A-Gone™ Salts:
Based on specific gravity (see Analytical methods) consumed by
dragout.
Hex-A-Gone™ Catalyst:
1 gal/10,000-25,000 amp–hrs. (150-400 mL/KAH). Start at 1 gal per
17,000 amp–hrs. (220 mL/KAH)
Hex-A-Gone™ 1020 Carrier:
1 gal/5,000 amp–hrs. (760 mL/KAH)
CAUTION: Careful, routine monitoring of pH is required for successful operation of Hex-A-Gone™
1020. DO NOT ALLOW THE pH TO EXCEED 3.8.
Bath Makeup per 1,000 gallons (3,785 L):
Use “General Purpose” makeup unless otherwise specified by Pavco representatives.
1. Add 800 gallons (3,000 L) of deionized water to a clean tank.
2. Heat the water to 130°F (54°C). Maintain at this temperature during make up procedure.
3. Add 2,335 pounds (1,060 kg) of Hex-A-Gone™ Salts slowly with good agitation.
4. For “High Efficiency” makeup, (9.5 g/L chrome) add 160 gallons (606 L) of Hex-A-Gone™ CR Make-
up. For “General Purpose” makeup, (7 g/L chrome) add 120 gallons (454 L) of Hex-A-Gone™ CR
Make-up.
5. After the Salts and Make-up are thoroughly dissolved, raise the solution level to 90% of operating
volume with deionized water.
6. Lower the pH of the solution to 1.8 with 50% sulfuric acid and agitate for 12 hours minimum to
establish the proper chromium complex.
7. After the 12 hour period, raise the pH over a two hour period to operating range with 45%
potassium hydroxide (low chloride grade).
8. Treat solution with 2 g/L activated carbon powder. Allow to stir for 2 hours then remove with
filter.
9. Add 12.4 gallons (46.9 L) of Hex-A-Gone™ 1020 Carrier, 1.5 gallons (5.7 L) of Hex-A-Gone™
Catalyst, 17.5 gallons (66.2 L) Hex-A-Gone™ Whitener, and 2 gallons (7.6 L) DecoTri MS.
10. Add DI water to the final volume.
11. Electrolyze the bath for a minimum of 2 amp-hours/gallon (0.5 amp-hours/L) as needed before
use. Confirm plating rate and coverage by hull cell before production use.
Operating Tips:
• Use routine additions of Hex-A-Gone™ 1020 Carrier and Hex-A-Gone™ Catalyst to maintain
good coverage, color, and thickness of the chromium deposit.
• Use routine additions of Hex-A-Gone™ Cr Maint. to maintain chromium levels. Hex-A-Gone™ CR
Make-up is normally only needed for new bath make-up or when Hex-A-Gone™ Complexor levels
are low.
• Higher chromium levels will improve the high current density range but can reduce coverage in
low current density areas.
• Use of waste treatment grade caustic is not recommended. Use caustic with a specification of
less than 50 ppm chloride (<.005%) to avoid chloride contamination issues. Chloride
accumulation can decrease life of anode coating.
4
Plating System Hex-A-Gone™ 1020
• Metallic contaminants MUST BE TREATED REGULARLY. Nickel in excess of 50 ppm, zinc in
excess of 10 ppm, or iron in excess of 30ppm can reduce the bath efficiency (slow down the rate
of deposition) as well as darken the deposit. Best practice is to use Premier Ion Exchange resin.
Another option is to electrolyze the solution at 18 amps/ft2
(2 amp/dm2
) in a continuous
electrowinning cell. Total combined metallic contaminants should be kept under 50 ppm in
order to achieve “blue” color.
• Carbon filtration is recommended to maintain good color and efficiency. Use 2 - 4 pounds of
granular activated carbon (1 - 1.5 kg) per 1,000 gallons (4,000 liters) of solution. Replace the
carbon every two weeks.
• Inspect the anode coating every three months. The anodes will require periodic recoating. Thin
anode coating will result in hex chrome formation and poor chromium coverage.
• Routinely check for hex chrome to confirm proper anode coating and addition rates. Hexavalent
chrome formation can be due to poor anode coating, low Hex-A-Gone™ 1020 Carrier, or bath
contaminants.
• Keep the specific gravity below 1.26 for optimal high current density performance.
• Catalyst levels will reduce gradually during downtime. Monday morning startup typically
requires extra Hex-A-Gone™ Catalyst (0.05-0.10%) to obtain desired plating rate.
Hex-A-Gone 1020 Components and Functions:
Hex-A-Gone™ CR Make-up (HG 106)
Provides the chromium salts necessary for a solution. Make-up can be used to replenish chrome if
Complexor levels are low. In this case, CR Makeup may be used in place of CR Maint. Do not use if
Complexor levels are normal.
Hex-A-Gone™ Salts (HG 116)
Provides the salts required to operate the system. Hex-A-Gone™ Salts are depleted when operating the
bath. Regular analysis and additions of this product are required. Do not add salts if the specific gravity
exceeds 1.24 g/L.
Hex-A-Gone™ Cr Maint. (HG 100)
Provides the correct balance of chromium metal and complexors to maintain the bath. Hex-A-Gone™ Cr
Maint. must be added on an amp-hour basis.
Hex-A-Gone™ 1020 Carrier (HG140)
This maintenance additive is fed on an amp-hour basis to maintain all the brightening and complexing
agents in the bath. It is fed in combination with Hex-A-Gone™ Catalyst. This additive replaced the
prior existing 1020 BC Maintenance. Use Hex-A-Gone™ 1020 Carrier to improve deposit brightness.
DecoTri MS (PPS30553)
Reduces surface tension, prevents gas streaks, and improves HCD range. DecoTri MS can be added on
an amp-hour basis. It is controlled by surface tension analysis.
Hex-A-Gone™ Whitener (HG 110)
Hex-A-Gone™ Whitener is contained in 1020 Carrier. It helps to maintain the characteristic color of
the deposit. Hex-A-Gone™ Whitener should only be added at the direction of Pavco technical personnel.
Hex-A-Gone™ Catalyst (HG 114)
Hex-A-Gone™ Catalyst controls the deposition rate. Typical addition is 0.025-0.10%. Extra Catalyst
will be needed in presence of zinc contamination. Add 0.1% Hex-A-Gone™ Catalyst at 20 ppm Zinc.
Catalyst must be added on an amp-hour basis. Excess Catalyst can cause hazing.
5
Plating System Hex-A-Gone™ 1020
Hex-A-Gone™ Extender (HG 101)
Hex-A-Gone™ Extender should only be added at the direction of Pavco technical personnel. This additive
will improve LCD coverage of the chrome. It will tend to darken the deposit with overuse, so use
minimally in 0.1% increments.
Hex-A-Gone™ Complexor (HG 115)
Hex-A-Gone™ Complexor should only be added at the direction of Pavco technical personnel. Low
Complexor can lead to poor throwing power and rapid formation of hexavalent chrome. Low Complexor
is indicated by a green solution color. High Complexor will cause reduced efficiency.
Analytical Procedures:
Hex-A-Gone™ Salts by titration
Equipment
• 5 mL pipette
• Magnetic stir plate and PTFE coated stir bar
• 150 mL beaker
• Calibrated pH meter
• Burette
Reagents
• Mannitol
• 1N sodium hydroxide
Procedure
1. Pipette a 5 mL bath sample into a 150 mL beaker.
2. Add 20 mL of deionized water.
3. Add a PTFE coated magnetic stir bar and mix solution on stir plate throughout the analysis.
4. Using a pH meter, adjust pH solution to 6.0-6.5 using either 1N sodium hydroxide or 1N sulfuric
acid. Record final pH.
5. Add 10 g of Mannitol (Excess Mannitol is necessary at all times).
6. Slowly titrate the solution with 1N sodium hydroxide until the recorded pH is reached. Add
additional Mannitol (2g) at the end. If pH drops, continue titrating.
7. If pH does not change, endpoint has been reached.
Calculation:
Hex-A-Gone™ Salts (g/L) = mL titrated X 49
Hex-A-Gone™ Salts by Specific Gravity:
Salt concentration can also be determined by Specific Gravity. Weigh 100 mL of plating solution on a
gram scale using a 100 mL volumetric flask. Be sure that flask is dry and determine tare weight of
empty flask. Subtract tare weight from total weight. Scale used must be accurate to +/- 0.1 grams.
Specific gravity = weight in grams / 100 mL
Use the chart below that is closest to your operating chrome concentration. If your Hex-A-Gone™ Salts
concentration by specific gravity does not match your Hex-A-Gone™ Salts by titration within 25 g/L,
consult a Pavco representative.
oz/gal Hex-A-Gone™ Salts = g/L Hex-A-Gone™ Salts /7.5
CAUTION: DO NOT ADD SALTS IF THE SPECIFIC GRAVITY EXCEEDS 1.25. Consult your Pavco
Representative if you Salts by titration are low and your specific gravity is high.
6
Plating System Hex-A-Gone™ 1020
5 g/L Chrome
SpG Salts (g/L)
1.176 240
1.191 260
1.208 280
1.220 300
1.235 320
7 g/L Chrome
SpG Salts (g/L)
1.191 240
1.204 260
1.216 280
1.226 300
1.238 320
9 g/L Chrome
SpG Salts (g/L)
1.201 240
1.212 260
1.226 280
1.239 300
1.252 320
7
Plating System Hex-A-Gone™ 1020
Analytical Procedures:
Chrome Metal
Equipment
• 5 mL pipette
• 250 mL Erlenmeyer flask
• Hot plate
• Burette
Reagents
• Sodium hydroxide
• 30% hydrogen peroxide
• 1:1 sulfuric acid
• 10% potassium iodide
• Starch solution
• 0.1N sodium thiosulfate
Procedure
1. Pipette a 5 mL bath sample into a 250 mL Erlenmeyer flask.
2. Add 100 mL of deionized water.
3. Add 2 g of sodium hydroxide to the flask and swirl to dissolve.
4. Add 2 mL of 30% hydrogen peroxide.
5. Boil the solution until all the peroxide is gone, at least 30 minutes.
6. Cool the solution to room temperature.
7. Add 10 mL of 1:1 sulfuric acid
8. Add 5 mL of 10% potassium iodide.
9. Titrate with 0.1 N sodium thiosulfate to a straw color.
10. Add 2 mL of starch indicator.
11. Continue the titration to the absence of a blue color which persists for 30 seconds.
Calculation: g/L total Cr = (mL of Na2S2O3) (N of Na2S2O3)(17.3)
—————————————————
(mL of sample)
% Hex-A-Gone™ Cr Maint. = g/L total Cr x 1.25
NOTE: Submit regular samples to your Pavco representative for routine monitoring of
• Hex-A-Gone™ Whitener
• Hex-A-Gone™ Complexor
• Surface Tension
• Metallic contaminants
• Chloride contamination
Monitoring these components and adjusting as needed is critical to the long term consistency of the
Hex-A-Gone™ 1020 process. Initial testing upon installation is recommended weekly. Thereafter,
monthly samples are usually sufficient.
8
Plating System Hex-A-Gone™ 1020
Contaminant Limits:
Contaminant Upper limits Effect
Copper <5 ppm Poor color, poor efficiency
Nickel <50 ppm Poor color, poor efficiency, streaks
Zinc <10 ppm Poor efficiency, haze in deposit
Iron <30 ppm Darkens deposit
Chloride <500 ppm Degrades anode coating
Fluoride <50 ppm Degrades anodes
Analytical Procedures:
Hexavalent Chrome Test for Hex-A-Gone™ 1020
Trivalent Chrome Solution (Qualitative)
Summary
This procedure determines whether hexavalent chrome is being produced at the anodes. This helps
determine anode quality as well as proper additive concentrations in solution.
Equipment
• 250 mL Erlenmeyer flask
• 1 mL pipette
• 50 mL graduated cylinder
Reagents
• Diphenylcarbazide, 0.5% in acetone
• Sulfuric acid, 50%
• Distilled or Deionized water (DI)
Procedure
1. Add 90 mL of DI water to a 250 mL Erlenmeyer flask.
2. Add 10 mL of 50% sulfuric acid with a graduated cylinder.
3. Add 1 mL diphenylcarbazide indicator solution. Observe for pink color. If solution is pink,
discard and wash all glassware before returning to step 1.
4. If solution is not pink after Step 3, pipette 1 mL of trivalent chrome solution into the flask.
5. Observe for the development of a pink color. Pink indicates presence of hexavalent chrome.
A barely distinguishable pink color indicates 20-50 ppm of hexavalent chrome.
Opaque pink/red indicates in excess of 500 ppm hexavalent chrome.
Notes:
• Take care not to contaminate diphenylcarbazide indicator solution with chromium solution.
Discard the indicator if contaminated. A colorless solution after step 3 demonstrates clean
indicator, glassware and reagents.
• Test the trivalent chrome plating bath immediately after sampling the bath. Any hexavalent
chrome generated at the anodes will rapidly react with bath additives and give false negative
results if sample is allowed to sit idle.
• Check the bath after 1, 4, and 8 hrs of production. Positive hex chrome tests can indicate a
defective anode coating. Consult your Pavco representative. Pink color in 1-4 hours will require
corrective action.
• If hexavalent chrome is present, check Hex-A-Gone™ Complexor levels. Adjust as needed in 2
g/L increments. Check feed rate for Hex-A-Gone™ 1020 Carrier and Hex-A-Gone™ Catalyst to
confirm optimum feed rate. Check contact on anodes and inspect for damaged coating. Check
anode current density and increase anode area. Send anodes to Pavco lab for coating thickness
testing. Send anodes out for recoating.
9
Plating System Hex-A-Gone™ 1020
Analytical Procedures:
Hull cell analysis
Equipment
• 10 Amp rectifier
• Heated hull cell
• Polished brass panels
• Stainless steel beaker
• Hot plate
• Stainless steel tongs
• Alkaline electrocleaner (Clean-R-2002) 8 oz/gal (60 g/L)
• 5% Sulfuric acid in 500 mL glass beaker
• Thickness tester, XRF or Kocour /equivalent destructive thickness tester
1. Heat cleaner in a stainless steel beaker to 140˚F (60˚C). Attach anode lead (+) from rectifier to
stainless steel beaker. Use stainless tongs connected to the cathode lead (-) to clean a bright
brass panel cathodically at 10 amps for 20-30 seconds. Rinse in clean water.
2. Immerse in 5% sulfuric acid for 5-10 seconds, agitate.
3. Rinse. Ensure panel has a water break free appearance. If not, repeat cleaning process or
change cleaner.
4. Place panel in preheated hull cell. Solution must be maintained at actual bath operating
temperature in order to be representative of actual plating conditions.
5. Run a 5 amp, 3 minute hull cell panel.
6. Measure thickness at 1.7 cm, 3.9 cm, 6.1 cm, and 7.9 cm from left edge of panel. If using x-ray
testing, ensure machine is calibrated for chrome over brass. If it is not calibrated for chrome
over brass, then panel must be nickel plated before running the chrome hull cell. Destructive
tester usually require nickel plated panels.
Note: Bright brass panels are preferred over dull panels, as they allow easy observation for chrome
deposit variations such as dullness.
Typical Deposit Thickness:
HCD
1.7 cm
3.9 cm
6.1 cm
LCD
7.9 cm
Chrome
(microinches)
3-5
4-6 3-5 1-2
(microns) 0.075-0.13 0.1-0.15 0.075-0.13 0.025-0.05
CD amps/ft2
amps/dm2
170
18
90
10
45
5
18
2
Troubleshooting Guide
Problem Cause Solution
HCD skip plate Low wetting agent Add up to 0.3% DecoTri MS
pH not in range Adjust pH with potassium hydroxide (low
chloride) or sulfuric acid
Low salts or chrome Check specific gravity, Hex-A-Gone™ Salts
and chrome. Adjust as needed
Low temperature Check and adjust
Low Catalyst Add 0.05% increments of Hex-A-Gone™
Catalyst
10
Plating System Hex-A-Gone™ 1020
Problem Cause Solution
Thin or no chromium
deposit
Low chemistry Check chrome, SpG, Hex-A-Gone™ Salts, pH
and adjust as needed
Low Catalyst Add 0.05% increments of Hex-A-Gone™
Catalyst
pH was too high or bath
is under used. Bath
needs low pH treatment.
Heat bath to 120°F (49°C). Lower the pH to 2
with sulfuric acid and maintain for 12 hours.
Slowly raise the pH to 3.3 - 3.5 with liquid
KOH. Electrolyze for 2 amp-hrs/gal
Metallic contamination Check for copper, nickel, iron, zinc.
Regenerate or replace resin or electrolyze the
bath at 18 ASF (1.9 ASD)
Hexavalent chrome
contamination
Run hex chrome test. Check anode coatings.
Treat with sodium metabisulfite until hex test
is negative. Add in a ratio of 3 parts sodium
metabisulfite:1part hexavalent chromium
(can typically be added in 0.05 g/L
increments). See section below on hex
chrome contamination.
Poor coverage w/ clean
LCD
Temperature out of
range
Adjust temperature to 120° - 140°F
(49° - 60°C)
Low chrome metal Analyze chrome and adjust to range with
Hex-A-Gone™ CR Maint.
Low Hex-A-Gone™ Salts Analyze and adjust the Hex-A-Gone™ Salts
concentration
Low Catalyst Add 0.05% increments or Hex-A-Gone™
Catalyst
Low Complexor (green
solution color)
Send sample to Pavco Laboratory for analysis.
Add Hex-A-Gone™ Complexor in 2 g/L
increments
Organic contamination Filter continuously through activated carbon.
Replenish wetter after treatment with up to
0.3% DecoTri MS
Dark or streaky LCD or
overall streaky or dark
deposit
Metallic contamination Check for copper, nickel, iron, zinc.
Regenerate or replace resin or electrolyze the
bath at 18 ASF (2ASD) to remove these
metals.
Thin white bands , dull or
“blue” deposit
Excess Hex-A-Gone™
Catalyst
Electrolyze or withhold adds of Hex-A-Gone™
Catalyst. If this is not sufficient, add 0.03%
increments of hydrogen peroxide until haze is
eliminated. Allow 20 minutes between
additions of peroxide.
Low Hex-A-Gone™ 1020
Carrier
Check Carrier level and adjust to 1-1.5%.
Check hull cell thickness and add 0.3%
increments of Carrier if thickness is above
normal.
White haze in LCD (strips
in 10% sulfuric)
Zinc contamination Check for dropped parts, electrolyze at 5-10
ASF or regenerate IX resin. Increased Hex-A-
Gone™ Catalyst can help improve efficiency
in the presence of zinc. (0.1% for 20 ppm)
11
Plating System Hex-A-Gone™ 1020
Problem Cause Solution
Constant hex chrome
issues
High anode current
density
Increase number of anodes
Degraded/ineffective
anode coating
Send anode to Pavco for thickness analysis.
Recoat anodes.
Low Hex-A-Gone™
Complexor levels
Submit sample to Pavco lab and adjust as
needed
Improper addition rates Check addition rates for Carrier, Catalyst
and CR Maint. Adjust as needed. Increase
addition rate of Carrier and Catalyst if
needed.
High zinc contamination Analyze for zinc. Pump tank and inspect
bottom for parts. Dummy plate to remove
zinc or regenerate ion exchange resin to
improve zinc removal capacity. Add extra
Hex-A-Gone™ Catalyst (0.05% increments)
until thickness returns
Short anode life (less
than 2-3 years)
Thin or poorly adherent
coating
Recoat anodes using qualified source
High fluoride (>50 ppm) Eliminate source. Do not use fluoridated acid
salts in acid dips prior to Hex-A-Gone™ 1020
High chloride (>500
ppm)
Improve rinsing after nickel. Use DI water for
makeup water. Do not use softened water.
Do not use hydrochloric acid to regenerate
resins
Waste Treatment:
Dispose of the concentrate or solutions thereof according to local waste treatment regulations.
Safety:
Handling– Pavco mandates that the following safety equipment be used when handling
chemicals in an electroplating environment: safety glasses, face shield, plastic or rubber apron,
rubber gloves and safety shoes. Chemicals should only be handled by trained and experienced
personnel.
Storage– Store Pavco products in a clean, well ventilated room which temperature remains above 45°F
(7°C). Pavco products should remain in their original container with the lid or cap tightened. Drum
pumps or pails must be clean prior to dispensing Pavco products to prevent contamination. If Hex-A-
Gone™ 1020 freezes during shipment or storage, warm the product to and mix it well before use.
Emergency Procedures– Refer to the MSDS for detailed emergency procedures.
Eye Contact– Seek immediate medical attention. Flush the eyes with water for 15 m minutes.
Skin Contact– Remove all contaminated clothing. Wash the skin with soap and water. Seek
medical attention.
Inhalation– Remove the person to an area with fresh air. Seek medical attention if necessary.
Ingestion– Seek immediate medical attention.
Spill- Dike the area to contain the spill. Refer to the MSDS for clean-up. Notify the proper
authorities if required.
*NOTE: Refer to the MSDS for detailed emergency medical procedures.
12
Plating System Hex-A-Gone™ 1020
Product Description & Shipping:
Hex-A-Gone™ Salts (HG116) is a white powder and is available in 100# containers.
Hex-A-Gone™ Complexor (HG115) is a white powder and is available in 40# containers.
Hex-A-Gone™ CR Make-up (HG106) is a dark blue green liquid with a specific gravity of 1.2- 1.3 with a
pH less than 3.
Hex-A-Gone™ CR Maint. (HG100) is a dark blue green liquid with a specific gravity of 1.2 - 1.3 with a
pH less than 3.
DecoTri ™-MS (PPS30553) is a white slightly turbid liquid with a specific gravity of 0.98 - 1.04 with a
pH greater than 3.0.
Hex-A-Gone™ Whitener (HG110) is a colorless liquid with a specific gravity of 1.0 - 1.1 and a pH less
than 9.
Hex-A-Gone™ Catalyst (HG114) is a pale yellow to slight pinkish liquid with a specific gravity of 0.90 -
1.04 and a pH greater than 12.
Hex-A-Gone™ Extender (HG101) is a green liquid with a specific gravity of 1.0 - 1.1 and a pH less than
3.0.
Hex-A-Gone™ 1020 Carrier (HG140) is a clear/slight yellow liquid with a specific gravity of 1.05 -
1.15 with a pH less than 8.0.
All liquid Hex-A-Gone™ products are available in 5 gallon containers and 55 gallon drums.
WARRANTY AND DISCLAIMER Technical information and recommendations contained herein are believed to be reliable, however, the accuracy or completeness thereof is not guaranteed. No statement or recommendation shall constitute a representation unless set forth in an agreement in writing by the seller and manufacturer. NO WARRANTY OR MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE IS
MADE. The following warranty is made in lieu of any other warranties, express, implied, or statutory. Products are warranted to be free from defects on material and workmanship at the time sold. The sole obligation of the seller and manufacturer under this warranty shall be to replace any product defective at the time sold. Under no circumstances shall the manufacturer or seller be liable for any loss, damage, expense, direct or consequential, arising out of the use of or inability to use the product. Materials shall not be returned to the seller or manufacturer without express
written permission. No information or suggestions given by us shall be deemed to be a recommendation to use any product in conflict with any existing patent rights.
Revision Date: 07/17/18