HEROBottom Combi for Building-inFSD Compressor with Frequency-Mode Control
![Page 2: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/2.jpg)
2
HERO
bottom combi for building- infactory ZS (Susegana)energy efficiency class A++1 FSD compressor with frequency-mode controlmagnetic valveelectronic of the ERF2000 familyuser interface in 2 variants:
AEG-Electrolux:2 separate 7-segment LED displaysother brands (Electrolux, Rex-Electrolux, Arthur Martin-Electrolux, and OEM):new LCD UI (similar to ERF2021)
![Page 3: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/3.jpg)
3
HERO Brands and ModelsNon-RoHS Compliant
925 701 651 Santo C91841-4i AEG-Electrolux925 701 652 Santo C91845-5i AEG-Electrolux
925 696 653 ERN2929 Electrolux925 696 654 ARN2934 ArthurMartin-Electrolux925 696 652 FI2210VA++ Rex-Electrolux925 696 655 IKE309-52T Küppersbusch
LED UI
LCD UI
![Page 4: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/4.jpg)
4
HERO Brands and ModelsRoHS Compliant
925 701 657 Santo C91841-4i AEG-Electrolux925 701 658 Santo C91845-5i AEG-Electrolux
925 696 656 ERN2929 Electrolux925 696 659 ARN2934 ArthurMartin-Electrolux925 696 658 FI2210VA++ Rex-Electrolux925 696 657 Pro Comfort 77700i Privileg925 696 660 IKE309-52T Küppersbusch
LCD UI
LED UI
![Page 5: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/5.jpg)
5
LED User Interface AEG-Electrolux
![Page 6: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/6.jpg)
6
LCD User InterfaceOther Brands
N.B.:service manual for this control not yet availablefor accessibility see respective pages in SM 599361769
![Page 7: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/7.jpg)
7
LCD User InterfaceOther Brands
SuperFreezing
Shopping / Super Cooling
MODE°C
NightMode* MINIDAC **
* Night Mode sometimes called Special Performance Mode
** DAC = Dynamic Air Cooling
![Page 8: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/8.jpg)
8
LCD User InterfaceOther Brands
the display will normally show freezer temperature, and can be switched for 10 sec to fridge temperature by pressing the °Cbutton
alarm condition: display flashing with red backlighting
![Page 9: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/9.jpg)
9
Electronic Control
based on ERF2000fridge air sensor FR AIRfridge evaporator sensor FR EVAPfreezer air sensor FZ AIRmechanical door switches for both compartments3 triacs on the power board control:- magnetic valve- fridge lighting- Minidac fan in the fridge (not present in AEG models)frequency mode signal for compressor control is supplied via contacts J6-2 und J6-3 on power board
![Page 10: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/10.jpg)
10
Position of The Sensors
![Page 11: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/11.jpg)
11
Cooling Circuit with Magnetic Valve
COMPRESSOR
CONDENSER
FRIDGEEVAPORATOR
FREEZEREVAPORATOR
CAPILLARY TUBES
MAGNETICVALVE
FR AIR
FZ AIR
FR EVAP
= sensors
![Page 12: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/12.jpg)
12
Connection of Capillaries to Magnetic Valve
Outlet marked “KS”to fridge capillary
Outlet marked “GS”to freezer capillary
![Page 13: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/13.jpg)
13
Compressor Control
the FSD compressor in this appliance works in the frequencymode the ERF2000 power board supplies 5V square signals with variable frequencyeach frequency is associated to a compressor speed as per the diagram next slide
![Page 14: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/14.jpg)
14
FSD CompressorSpeed vs. Frequency
![Page 15: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/15.jpg)
15
Control of The MINIDAC Fan
the Minidac fan is switched onif selected by the user with the MODE button (the fan symbol will be shown in the display)if super cooling mode is selected, i.e. the fridge is set to 2°Cfor 6 hours (the term “Shopping” is used for some brands)by software, depending on ambient temperature, difference between set and actual air temperature in the fridge, door opening time, etc.
![Page 16: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/16.jpg)
16
FSD CompressorFrequency Mode Control
![Page 17: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/17.jpg)
17
Compressor ControlNormal Operation
compressor speed is determined by software, basically as afunction of
ambient temperaturefreezer setting
further to this, speed is temporarily increased ifcummulated door opening time is longer,the difference between setting and actual temperature is higher
the compressor cycles are sensor-controlled :CUT-IN: (FR AIR and FR EVAP) or FZ AIRCUT-OUT: FR AIR and FZ AIR
magnetic valve control:position KS: FR AIR and FR EVAPposition GS: FR AIR
![Page 18: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/18.jpg)
18
FSD CompressorSpeed in Normal Operation
0
500
1000
1500
2000
2500
3000
3500
4000
4500
-24°C -23°C -22°C -21°C -20°C -19°C -18°C -17°C -16°C -15°C
Tamb< 28°C
28°C < Tamb < 35°C
Tamb > 35°C
Compressor Speed[RPM]
Freezer Setting
![Page 19: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/19.jpg)
19
Compressor ControlFast Freezing
Continuous compressor run for max. 52 hoursat 3793 RPM if ambient temperature is lower than 35°Cat 4000 RPM if ambient temperature is higher than 35°C
![Page 20: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/20.jpg)
20
Compressor ControlNight Mode
Night Mode (labelled „Special Performance Mode“ for some brands) is designed for minimum noise if ambient temperature is above 14°C, the compressor is running continuously, at the speed shown in the graph next slideif ambient temperature is below 14°C, the compressor runs at 1000 RPM, but with sensor-controlled on/off cycles
![Page 21: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/21.jpg)
21
Night Mode:Speed vs Ambient Temperature
0
500
1000
1500
2000
2500
14 16 18 20 22 24 26 28 30 32 34 36 38
Compressor Speed[RPM]
Ambient Temperature [°C]
![Page 22: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/22.jpg)
22
FSD CompressorConnections
![Page 23: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/23.jpg)
23
FSD CompressorConnections
![Page 24: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/24.jpg)
24
FSD CompressorConnections
![Page 25: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/25.jpg)
25
FSD CompressorConnections
![Page 26: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/26.jpg)
26
Service Mode
Appliance plugged to power supply
At least one door has to be open
Switch off appliance using main switch
![Page 27: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/27.jpg)
27
Service Mode
Within 10 seconds, simultaneously press the “°C” and the “Mode” buttons for 5 seconds
![Page 28: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/28.jpg)
28
Service Mode
1. Long beep, all LCD elements are on, then offPress “°C” or “Mode” to advance to the next steps
2. Compressor test (display shows “0”)For this and the following load tests use the “ON/OFF” button toswitch load on or off. Load on is shown by in the display. When advancing to the next test, the load is left in the last status.
3. Magnetic valve (display shows “1”)
4. Fridge lighting (display shows “2”)
![Page 29: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/29.jpg)
29
Service Mode
5. MINIDAC fan (display shows “3”)
6. Door switchesleft digit in display for freezer door / right digit for fridge door“0” door closed / “1” door open
7. Potentiometer: “0” to “7” shown in display, depending on positionno button pressed - L.H. pot. “ON/OFF” pressed and in display - R.H. pot.
8. LCD backlighting: all colours and intensities are shown in sequence
![Page 30: HERO - Electrolux Group Service Support€¦ · · 2006-07-202 HERO bottom combi for building- in factory ZS (Susegana) energy efficiency class A++ 1 FSD compressor with frequency-mode](https://reader034.fdocuments.us/reader034/viewer/2022051803/5b0d9b777f8b9a952f8dc26f/html5/thumbnails/30.jpg)
30
Service Mode
9. Temperature sensor test:E0 no faultE1 evaporator sensor faultE2 ambient sensor faultif both faulty, evaporator sensor has priorityair sensor faults are shown in the user mode
10. EEPROM code and software variant code:each code starts with a long beepcharacters of the same code are divided by short beepsautomatic advance from on character to the next
11. After this, the magnetic valve is activated 6 times
12. Press “ON/OFF” to end the service mode(without this action, service mode will end automatically after 40 minutes)