HERMES Recoil Detector
description
Transcript of HERMES Recoil Detector
![Page 1: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/1.jpg)
Roberto Francisco Pérez BenitoOn behalf the HERMES Collaboration
European Graduate School
Lecture Week on Hadron PhysicsJyväskylä, Aug 25-29, 2008
HERMES Recoil Detector
![Page 2: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/2.jpg)
2
OutlineOutlineOutlineOutline
Motivation
The Hermes Recoil Detector
Performance
Outlook
![Page 3: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/3.jpg)
3
The Spin Structure of the NulceonThe Spin Structure of the NulceonThe Spin Structure of the NulceonThe Spin Structure of the NulceonNulceon Spin:
Spin of quarks
measured in DIS
HERMES: Spin of gluons, first Measurements
expected to be small Orbital angular momentum of
quarks Orbital angular momentum of
gluons
unknown
Accss to via Deeply Virtual Compton Scattering (DVCS)
![Page 4: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/4.jpg)
4
Generalized Parton Distributions (GPDs)Generalized Parton Distributions (GPDs)Generalized Parton Distributions (GPDs)Generalized Parton Distributions (GPDs)
Ji Sum Rule – Ji, PRL 78(1997)610
parton longitudinal momentum fractions
fraction of the momentum transfer
invariant momentum transfer to the nucleon
GPDs
![Page 5: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/5.jpg)
5
GPDs and the DVCS processGPDs and the DVCS processGPDs and the DVCS processGPDs and the DVCS process
DVCS final state is indistinguishable from theBethe-Heitler Process (BH) → Amplitudes add Coherently
Photon-Production cross section:
Interference Term
![Page 6: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/6.jpg)
6
DVCS MeasurementsDVCS MeasurementsDVCS MeasurementsDVCS Measurements
calculable in QED with the knowledge of the Form Factors
is parameterized in terms of Compton Form Factors
(convolutions of GPDs )
At HERMES kinematics:
GPDs accessible through cross-section differences and azimuthal asymmetries via interference term I → Magnitude + Phase(GPDs enter in linear combinations)
![Page 7: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/7.jpg)
7
The HERMES Spectrometer (before 2006)The HERMES Spectrometer (before 2006)The HERMES Spectrometer (before 2006)The HERMES Spectrometer (before 2006)
Polarize gas targets: H,D,HeUnpolarize gas targets: H,D,N,He,Ne,Xe,Kr
Fixed target experiment (uses 27.6 GeV/c HERA lepton Beam)
Recoiling proton undetected large background contamination (15%)
![Page 8: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/8.jpg)
8
Exclusivity for DVCS via Missing Mass Exclusivity for DVCS via Missing Mass Exclusivity for DVCS via Missing Mass Exclusivity for DVCS via Missing Mass Exactly one DIS lepton and one photon detected in the Calorimeter.
Recoiling proton undetected.
Exclusivity via Missing Mass
exclusive region
Overall background contribution in exclusive region
![Page 9: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/9.jpg)
9
The HERMES Spectrometer (2006 - 2007)The HERMES Spectrometer (2006 - 2007)The HERMES Spectrometer (2006 - 2007)The HERMES Spectrometer (2006 - 2007)
Recoil detector installed for the last two years of data taking Recoiling proton detected background contamination <1%
![Page 10: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/10.jpg)
10
Recoil DetectorRecoil Detector Recoil DetectorRecoil Detector Photon Detector 3 layers of Tungsten/Scintillator
1 Tesla Superconducting Solenoid
Scintillating Fiber Detector 2 Barrels 2 Parallel & 2 Stereo-Layers in
each barrelSilicon Detector
2 Layer of 16 double-sides sensors 97×97 mm2 active area each Inside HERA vacuum
Target Cell
![Page 11: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/11.jpg)
11
Alignment of the SFT Alignment of the SFT Alignment of the SFT Alignment of the SFT
![Page 12: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/12.jpg)
12
Measurements of dedicated SFT run were used and tested on cosmic data collected with Recoil detector
Residuals (280 µm) are in good agreement with expectations from ideally aligned Monte-Carlo (220 µm)
SFT Paralleltop
=0.28mm
Si and PD alignment respect SFT
Results of Alignment of SFT Results of Alignment of SFT Results of Alignment of SFT Results of Alignment of SFT
![Page 13: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/13.jpg)
13
Ep Elastic ScatteringEp Elastic ScatteringEp Elastic ScatteringEp Elastic Scattering
Detect scattered electron in the Forward spectrometer and protons in the Recoil
Correlation of angles reconstructed in the Forward spectrometer and the Recoil Detector can be used for the relative alignment of these detector systems
![Page 14: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/14.jpg)
14
Momentum ReconstructionMomentum Reconstruction Momentum ReconstructionMomentum Reconstruction
![Page 15: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/15.jpg)
15
Momentum ReconstructionMomentum Reconstruction Momentum ReconstructionMomentum Reconstruction
![Page 16: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/16.jpg)
16
Momentum ReconstructionMomentum Reconstruction Momentum ReconstructionMomentum Reconstruction
![Page 17: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/17.jpg)
17
HERMES magnet
Recoil detector Energy loss of single fiber from pions Leading fibers from tracks were selected MIP’s position are stable from different time periods
Energy Deposit of MIP‘s Energy Deposit of MIP‘s Energy Deposit of MIP‘s Energy Deposit of MIP‘s
![Page 18: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/18.jpg)
18
Recoil Particle IdentificationRecoil Particle IdentificationRecoil Particle IdentificationRecoil Particle Identification
HERMES magnet
Recoil detector
![Page 19: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/19.jpg)
19
Collected statistic (preliminary) with recoil detector
Electron beam 2006 (only SFT operational):
H : 5k DVCS (3Mio. DIS), D : 1k DVCS (0.8Mio. DIS)
Positron beam 2006/07 (all subdetectors fully operational)
H : 41k DVCS (38Mio. DIS), D : 7.5k DVCS (10Mio. DIS)
Data tacking and PerformanceData tacking and PerformanceData tacking and PerformanceData tacking and Performance
2
2
2
2
![Page 20: HERMES Recoil Detector](https://reader034.fdocuments.us/reader034/viewer/2022051002/56815876550346895dc5d60c/html5/thumbnails/20.jpg)
20
Outlook Outlook Outlook Outlook Analysis of data with Recoil Detector
for exclusive photons and mesons Exclusive meson cross-sections Exclusive meson cross-section ratios Spin Density Matrix Elements Exclusive πˉ and π° impossible without Recoil Detector!