Helpful Hints for Inspection and Maintenance of Electric ...g...faulty connections. 3286 CLAMP ON...
Transcript of Helpful Hints for Inspection and Maintenance of Electric ...g...faulty connections. 3286 CLAMP ON...
For High Current Measurements(5000A AC Flexible Clamp Sensor)
For Temperature Anomaly Analysis
Easy Current Recording
For Power Quality Analysis
For Waveform Anomaly Analysis
HHHHeeeellllppppffffuuuullll HHHHiiiinnnnttttssss ffffoooorrrr IIIInnnnssssppppeeeecccctttt iiiioooonnnn aaaannnndddd MMMMaaaaiiiinnnntttteeeennnnaaaannnncccceeeeooooffff EEEElllleeeeccccttttrrrr iiiicccc PPPPoooowwwweeeerrrr EEEEqqqquuuuiiiippppmmmmeeeennnntttt aaaannnndddd HHHHoooowwww ttttooooIIIInnnnvvvveeeesssstttt iiiiggggaaaatttteeee tttthhhheeee CCCCaaaauuuusssseeee ooooffff PPPPoooowwwweeeerrrr PPPPrrrroooobbbblllleeeemmmmssss
• Diagnose faults in UPS and batteries with models such as the 3551• Reveal malfunctions in transmission equipment with Model 8855
Power Transmission Facilities• Measure power system harmonics with Models 3196, 8807-51/8808-51
and 3166• Measure power system flicker with Model 3196• Measure high-tension power pole current and voltage with Model 3636-20• Monitor distribution panel enclosure temperature with Model 3460
Power Distribution Facilities
Multiple Energy Monitoring
• Record vault temperature and humidity with Model 3641-20 Data Logger Series
Underground Power Transmission Facilities
• Monitor distribution panel voltages and currents with Models 3636-20 and 3637-20
• Monitor cumulative power metering with Models 3166 and 3639-20• Measure standby power with Model 3332• Collect energy saving measurements with Model 3166 and
3636-20 Data Logger Series
3551
3196
3641-20
3166
DDDDiiiisssstttt rrrr iiiibbbbuuuutttt iiiioooonnnn PPPPoooowwwweeeerrrr LLLLiiiinnnneeee
PPPPoooowwwweeeerrrr PPPPoooollll eeee HHHHoooommmmeeee
SSSScccchhhhoooooooollllPPPPrrrr iiiimmmmaaaarrrryyyy SSSSuuuubbbbssssttttaaaatttt iiiioooonnnn
BBBBuuuuiiii lllldddd iiiinnnnggggssss
Power Meter
Ground Fault Protector
Distribution PanelSafety Breaker
6,600V
Underground Cable
SSSSmmmmaaaa llll llll FFFFaaaaccccttttoooorrrryyyy
LLLLaaaarrrrggggeeee FFFFaaaaccccttttoooorrrryyyy
66,600V to 77,000V
66,600V to 154,000V
Maintain, Inspect and Manage the VMaintain, Inspect and Manage the Various Electrical arious Electrical
• For testing protective relays, Models 8841, 8842 and 8826• For testing circuit breakers, Model 8841 and 8842• For recording voltage and current waveforms during ground faults,
Models 8841, 8842 and 8826• For checking PT/CT circuit wiring, Model 3196• For measuring miniature circuit breaker (miniclat) contact resistance, Model 3227• For monitoring temperature in substations, Model 3460• For measuring noise in substations, Model 3430• For recording anomalies in unattended substations, Models 8807-01, 8808-01 and 3196
Substation and Control Station Facilities
• Investigate wind and solar generator power quality with Model 3196• Confirm geothermal power generation conditions with Model 3193• Record fuel cell voltage output with Models 8420-01 and 8421-01
Clean Energy EquipmentModels 8841, 8842, 8826 and 8855 MEMORY HiCORDERs:• For testing load breakers• For testing protective relays• For confirming control signals• For recording motor start current
Models 3166 and 3196: For confirming drive power
Model 3641-20 Data Logger Series: For measuring temperature withinpanel enclosures
Power Generation Facilities
8421-018855
3460
HHHHiiiigggghhhh TTTTeeeennnnssss iiiioooonnnn TTTTrrrraaaannnnssssmmmmiiiissssssss iiiioooonnnn LLLLiiiinnnneeeessss
SSSSuuuuppppeeeerrrrvvvvoooollll ttttaaaaggggeeee TTTTrrrraaaannnnssssffffoooorrrrmmmmeeeerrrr SSSSuuuubbbbssssttttaaaatttt iiiioooonnnn
NNNNuuuucccc llll eeeeaaaarrrr PPPPoooowwwweeeerrrr PPPPllllaaaannnntttt
HHHHyyyyddddrrrrooooeeee lllleeeecccctttt rrrr iiii cccc PPPPoooowwwweeeerrrr PPPPllllaaaannnntttt
FFFFuuuueeee llll BBBBuuuurrrrnnnniiiinnnngggg PPPPoooowwwweeeerrrr PPPPllllaaaannnntttt
110,000V to 154,000V
187,000V to 500,000V
Energies from the Power Plant to the Factory or Home!Energies from the Power Plant to the Factory or Home!
Memory HiCORDERs
Clamp-On Power HiTESTERs, Power HiTESTERs
Data Logger Series
8807-51, 8808-51MEMORY HiCORDERsThe -51 models can measure harmonicwaveforms. Portable waveform recorders withattachable two- and four-channel printers.
8841/8842MEMORY HiCORDERsRemote control capability by PC through aLAN. Sixteen digital and analog channels witha variety of input modules.
8826 MEMORY HiCORDERThirty-two isolated analog and 32 logic inputs.High speed waveform recorder with LAN andlarge capacity memory support.
8855 MEMORY HiCORDERIsolated eight-channel digital high speedmemory recorder with 20 MS/s. Large internalmemory allows efficient overall analysis ofunexpected phenomena and waveformanomalies.
3166CLAMP ON POWER HiTESTERClamp type power meter enables processingand analysis on a PC by saving measurementdata for power management on a floppy disk.
9667FLEXIBLE CLAMP ON SENSORMeasures up to 5000A AC. Support for largediameter (254-mm) conductors is ideal formeasurement and quality management of highcurrent circuits with Model 3196.
3196POWER QUALITY ANALYZERMonitor and record power quality of electricaltransmission and distribution systems, with LANsupport. Reliably captures abnormal powerphenomena for optimal troubleshooting analysis.
3332 POWER HiTESTERSingle-phase power meter measures low(standby) power levels of 1W or less. Three-phase Model 3331 is also available.
3641-20 HUMIDITY LOGGERInexpensive, easy-to-use miniature loggercollects temperature, humidity,instrumentation and various analog data foreasy management on a PC.
3636-20 CLAMP LOGGEREasily record AC current with this clamp. The3637-20 AC Voltage Logger provides voltagerecording.
3639-20 PULSE LOGGEREasily count pulses output from power or flowmeters. Includes an alarm output settingfunction.
8420-01/8421-01MEMORY HiLOGGERsThese loggers with LAN support provide up to8 or 16 isolated channels for voltage,temperature and pulse inputs.
3460 2D THERMO HiTESTERDisplays combined infrared images and multi-point measurement maps. Sixty-four independent temperaturemeasurements are ideal for monitoring fortemperature anomalies.
3550/3551BATTERY HiTESTERInstantly detects weak condition of varioussecondary batteries. Measures withoutinterrupting the UPS.
3227 mΩ HiTESTERLow-resistance meter has resolution to 10 µΩ,while supporting high speed sampling.Includes a probe for miniclat measurements.
3660 LAN CABLE HiTESTERIdeal for ensuring reliable installation andmaintenance of UTP cable. Includes thecapability to verify wiring integrity and detectfaulty connections.
3286CLAMP ON POWER HiTESTERHandy power meter with harmonicmeasurement function. Battery operationallows power and harmonic measurements tobe taken anywhere.
3281/3282DIGITAL CLAMP ON HiTESTERSatisfies CAT III 600V safety standards.Provides multiple functions such as RMSmeasurements ideal for measuring distortedwaveforms, and crest factor display function.
3257-51 DIGITAL HiTESTERSatisfies CAT III 1000V. This DMM isdesigned for particular safety when measuringtrue RMS, with a crowbar terminal thatprevents erroneous operations.
8205-10/8206-10MICRO HiCORDERSimple operations record voltage and currentfluctuations.
Inspection and Other Related Measurement Devices