HEATING THERMOSTATS FCU THERMOSTATS OEM/ODM …E6 HT01 HT05 HT08 HT09 HT07 HT10 E8.2 E8.4..RF TKB85...

32
TKB Home www.tkbhome.com HEATING THERMOSTATS FCU THERMOSTATS OEM/ODM SERVICES

Transcript of HEATING THERMOSTATS FCU THERMOSTATS OEM/ODM …E6 HT01 HT05 HT08 HT09 HT07 HT10 E8.2 E8.4..RF TKB85...

  • TKBHome

    www.tkbhome.com

    HEATING THERMOSTATS

    FCU THERMOSTATS

    OEM/ODM SERVICES

    TKB CONTROL SYSTEM LIMITED

    Tel: (86 577) 61787335 Fax: (86 577)61787705

    E-mail:sales@tkbhome http://www.tkbhome.com

    Add: No. 8 Xiqiao Road, Liushi, Yueqing, Zhejiang, China 325604 3YEARSWARRANTY

    ISO9001:2008

  • CONTENTS

    HT03 HT06 HT12

    TKB60 TKB75 TKB43 TKB430 E5

    E6 HT01 HT05 HT08 HT09

    HT07 HT10 E8.2 E8.4..RF

    TKB85 E72

    TKB50

    We devote ourself to R&D, production, sale and marketing of our energy

    saving products. Our core business is central air-conditioning &radiant

    floor heating, Z-wave Smart Home Products, Central vacuums and

    ventilation products.

    ABOUT TKBHOMEis located in Yueqing City,which is very

    famous for the production of “Low Voltage Application” in Zhejiang

    Province, China.

    TKB CONTROL SYSTEM LIMITED

    The adaption of setups like “ Scientific Management and Credit Operati

    -on” is fundamental to establish solid relationships with our customers.

    We will try our best to provide a friendly, dast and effective service for

    you.

    As a manufacture, TKBHOME have passed “ISO9001:2008” quality

    management system.

    We acquired the “CE certification” for all products. By carefully choosing

    qualified suppliers and making use of a convenient logistic network,we

    can ensure to carry out all orders on time combined with highest

    possible amount of accuracy.

    TKBHOME is able to customize products individually for each of our

    customers to meet their diverse requirements. So we are also mainly

    exporting OEM/ODM services. Except Chinese mainland, we already

    have experience in exporting to Russia, Germany, UK, Poland, New

    Zealand, Israel, Croatia, Slovakia, Czech, Iraq, Cyprus, Turkey ,

    Singapore and Hongkong etc.

    TKB101 TKB102 E51 E91

    TKB602TKB400TKB301

    E92

  • CONTENTS

    HT03 HT06 HT12

    TKB60 TKB75 TKB43 TKB430 E5

    E6 HT01 HT05 HT08 HT09

    HT07 HT10 E8.2 E8.4..RF

    TKB85 E72

    TKB50

    We devote ourself to R&D, production, sale and marketing of our energy

    saving products. Our core business is central air-conditioning &radiant

    floor heating, Z-wave Smart Home Products, Central vacuums and

    ventilation products.

    ABOUT TKBHOMEis located in Yueqing City,which is very

    famous for the production of “Low Voltage Application” in Zhejiang

    Province, China.

    TKB CONTROL SYSTEM LIMITED

    The adaption of setups like “ Scientific Management and Credit Operati

    -on” is fundamental to establish solid relationships with our customers.

    We will try our best to provide a friendly, dast and effective service for

    you.

    As a manufacture, TKBHOME have passed “ISO9001:2008” quality

    management system.

    We acquired the “CE certification” for all products. By carefully choosing

    qualified suppliers and making use of a convenient logistic network,we

    can ensure to carry out all orders on time combined with highest

    possible amount of accuracy.

    TKBHOME is able to customize products individually for each of our

    customers to meet their diverse requirements. So we are also mainly

    exporting OEM/ODM services. Except Chinese mainland, we already

    have experience in exporting to Russia, Germany, UK, Poland, New

    Zealand, Israel, Croatia, Slovakia, Czech, Iraq, Cyprus, Turkey ,

    Singapore and Hongkong etc.

    TKB101 TKB102 E51 E91

    TKB602TKB400TKB301

    E92

  • Selection Table

    Application

    Technical Data

    Introduction

    TKB85 is used for 2-position control with on/off output for the control

    the temperature by means of an NTC sensor placed externally

    or internally in the thermostat.

    The thermostat acquires the actual temperature with its built-in sensor

    or floor sensor, and the heating contact will close when the room

    temperature falls below the selected setpoint.

    For the control of warm-water(floor) heating systems and direct

    electric heating systems used in Commercial buildings, Residential

    buildings, Light industrial buildings...

    Voltage

    Power consumption

    Setting range

    Ambient temperature

    Switching differential

    Protective housing

    Housing material

    Floor sensor

    AC230V(AC110V/AC24V available)

    5W

    5℃ 50℃

    -

    ±1K

    IP20

    Self-extinguishing PC

    Rubber-thermoplastic NTC sensor, cable length is 3m

    5℃~50℃

    SensorCurrentModel Number

    64

    64

    64

    Built-in sensor

    Built-in sensor

    Floor Sensor

    3A

    16A

    16A

    TKB85.13

    TKB .16

    TKB .26

    85

    85

    Loading (PCS/Carton)

    Wiring Diagram

    1 2 3 4 5 6 7

    TKB85.13 Imax 3A=

    TKB85.16 Imax 16A=

    1 2 3 4 5 6 7

    TKB85.26 Imax 16A=

    Sensor

    Technical Data

    Application

    Introduction

    Selection Table

    SensorModel Number

    64

    64

    64

    64

    3A

    16A

    16A

    16A

    For the control of warm-water(floor) heating systems and direct electric

    heating systems used in Commercial buildings, Residential buildings, Light

    industrial buildings...

    E72 is used for 2-position control with on/off output for the control the

    temperature by means of an NTC sensor placed externally or internally in

    the thermostat.

    The thermostat acquires the room temperature with its built-in sensor or floor

    sensor, and the heating contact will close when the room temperature falls

    below the selected setpoint.

    Voltage

    Power consumption

    Setting range

    Limitation scale

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    Floor sensor

    AC230V(AC110V/AC24V available)

    5W

    5℃ 40℃

    25℃~50℃(E72.36)

    ±0.5K

    -5℃~50℃

    IP20

    Self-extinguishing PC

    Rubber-thermoplastic NTC sensor, cable length is 3m

    E72.13

    .16

    .26

    .36

    E72

    E72

    E72

    Built-in sensor

    Built-in sensor

    Floor sensor

    Built-in & floor sensor(recommend)

    CurrentLoading

    (PCS/Carton)

    Wiring Diagram

    E72.13 Imax 3A=

    E72.16 Imax 16A=

    E72.26 Imax=16A

    Sensor

    E72.36Imax=16A

    E72...

    Electrical Heating ThermostatFloor HeatingFloor Heating

    TKB85...

    Electrical Heating Thermostat

    01/www.tkbhome.com www.tkbhome.com/02

  • Selection Table

    Application

    Technical Data

    Introduction

    TKB85 is used for 2-position control with on/off output for the control

    the temperature by means of an NTC sensor placed externally

    or internally in the thermostat.

    The thermostat acquires the actual temperature with its built-in sensor

    or floor sensor, and the heating contact will close when the room

    temperature falls below the selected setpoint.

    For the control of warm-water(floor) heating systems and direct

    electric heating systems used in Commercial buildings, Residential

    buildings, Light industrial buildings...

    Voltage

    Power consumption

    Setting range

    Ambient temperature

    Switching differential

    Protective housing

    Housing material

    Floor sensor

    AC230V(AC110V/AC24V available)

    5W

    5℃ 50℃

    -

    ±1K

    IP20

    Self-extinguishing PC

    Rubber-thermoplastic NTC sensor, cable length is 3m

    5℃~50℃

    SensorCurrentModel Number

    64

    64

    64

    Built-in sensor

    Built-in sensor

    Floor Sensor

    3A

    16A

    16A

    TKB85.13

    TKB .16

    TKB .26

    85

    85

    Loading (PCS/Carton)

    Wiring Diagram

    1 2 3 4 5 6 7

    TKB85.13 Imax 3A=

    TKB85.16 Imax 16A=

    1 2 3 4 5 6 7

    TKB85.26 Imax 16A=

    Sensor

    Technical Data

    Application

    Introduction

    Selection Table

    SensorModel Number

    64

    64

    64

    64

    3A

    16A

    16A

    16A

    For the control of warm-water(floor) heating systems and direct electric

    heating systems used in Commercial buildings, Residential buildings, Light

    industrial buildings...

    E72 is used for 2-position control with on/off output for the control the

    temperature by means of an NTC sensor placed externally or internally in

    the thermostat.

    The thermostat acquires the room temperature with its built-in sensor or floor

    sensor, and the heating contact will close when the room temperature falls

    below the selected setpoint.

    Voltage

    Power consumption

    Setting range

    Limitation scale

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    Floor sensor

    AC230V(AC110V/AC24V available)

    5W

    5℃ 40℃

    25℃~50℃(E72.36)

    ±0.5K

    -5℃~50℃

    IP20

    Self-extinguishing PC

    Rubber-thermoplastic NTC sensor, cable length is 3m

    E72.13

    .16

    .26

    .36

    E72

    E72

    E72

    Built-in sensor

    Built-in sensor

    Floor sensor

    Built-in & floor sensor(recommend)

    CurrentLoading

    (PCS/Carton)

    Wiring Diagram

    E72.13 Imax 3A=

    E72.16 Imax 16A=

    E72.26 Imax=16A

    Sensor

    E72.36Imax=16A

    E72...

    Electrical Heating ThermostatFloor HeatingFloor Heating

    TKB85...

    Electrical Heating Thermostat

    01/www.tkbhome.com www.tkbhome.com/02

  • Mechanical Room Thermostat is designed to provide

    automatic control for thermal actuator, electric control valves

    etc. in heating installations. User gets more comfortable and

    economical heating by adjusting the temperature as needed.

    Introduction

    Technical Data

    Voltage

    Set Point Range

    Ambient

    Relative Humidity

    Accuracy

    Protection Class

    Housing

    Current load

    24V,110V or 230V

    3A/6A

    5 35

    0 50

    85%

    ±1

    IP30

    ABS to UL94-5 fire retardant plastic

    ~ ℃

    ~ ℃

    Features

    >

    >

    >

    >

    >

    Water heating system

    On/off Control

    Bellow Sensor

    Easy Calibration

    Surface mounting

    Mounting

    >

    >

    >

    Detach the cover, loosen the bottom screws, and then fix on the wall. Water heating system

    Fixed HT-03 150cm high from floor On/off Control

    Please do not mount the HT-03 near doors and windows because of weather circulation.

    Wiring Diagram

    20.6

    4

    30.06

    5 4 3 2 1

    CO

    OL

    HEAT

    L

    N

    Mechanical Room Thermostat is designed to provide

    automatic control for thermal actuator, electric control valves etc.

    in heating installations. User gets more comfortable and economical

    heating by adjusting the temperature as needed.

    Introduction

    Technical Data

    Voltage

    Current load

    Set Point Range

    Ambient

    Relative Humidity

    Accuracy

    Housing

    24V,110V or 230V

    3A/6A

    10℃~30℃

    5℃~50℃

    85%

    ±1℃

    ABS to UL94-5 fire retardant plastic

    Wiring Diagram

    B-1(T6360A)

    16(5)A4

    3

    1

    1

    2

    N

    L

    220/240V-50/60HZ

    B-2(T6360A)

    16(5)A4

    3

    1

    1

    2

    N

    L

    220/240V-50/60HZ

    5

    6

    5

    B-3(T6360A)

    16(5)A4

    3

    1

    2

    N

    L

    220/240V-50/60HZ

    2

    B-4(T6360A)

    16(5)A4

    3

    1

    2

    N

    L

    220/240V-50/60HZ

    5

    6

    5

    2

    B-5(T6360A)

    2

    1

    1 2

    6(3)A

    220/240V-50/60HZ

    N

    L

    HT06...

    Mechanical HeatingThermostatFloor HeatingFloor Heating

    HT03...

    Mechanical Heating Thermostat

    03/www.tkbhome.com www.tkbhome.com/04

    HT06HT03

  • Mechanical Room Thermostat is designed to provide

    automatic control for thermal actuator, electric control valves

    etc. in heating installations. User gets more comfortable and

    economical heating by adjusting the temperature as needed.

    Introduction

    Technical Data

    Voltage

    Set Point Range

    Ambient

    Relative Humidity

    Accuracy

    Protection Class

    Housing

    Current load

    24V,110V or 230V

    3A/6A

    5 35

    0 50

    85%

    ±1

    IP30

    ABS to UL94-5 fire retardant plastic

    ~ ℃

    ~ ℃

    Features

    >

    >

    >

    >

    >

    Water heating system

    On/off Control

    Bellow Sensor

    Easy Calibration

    Surface mounting

    Mounting

    >

    >

    >

    Detach the cover, loosen the bottom screws, and then fix on the wall. Water heating system

    Fixed HT-03 150cm high from floor On/off Control

    Please do not mount the HT-03 near doors and windows because of weather circulation.

    Wiring Diagram

    20.6

    4

    30.06

    5 4 3 2 1

    CO

    OL

    HEAT

    L

    N

    Mechanical Room Thermostat is designed to provide

    automatic control for thermal actuator, electric control valves etc.

    in heating installations. User gets more comfortable and economical

    heating by adjusting the temperature as needed.

    Introduction

    Technical Data

    Voltage

    Current load

    Set Point Range

    Ambient

    Relative Humidity

    Accuracy

    Housing

    24V,110V or 230V

    3A/6A

    10℃~30℃

    5℃~50℃

    85%

    ±1℃

    ABS to UL94-5 fire retardant plastic

    Wiring Diagram

    B-1(T6360A)

    16(5)A4

    3

    1

    1

    2

    N

    L

    220/240V-50/60HZ

    B-2(T6360A)

    16(5)A4

    3

    1

    1

    2

    N

    L

    220/240V-50/60HZ

    5

    6

    5

    B-3(T6360A)

    16(5)A4

    3

    1

    2

    N

    L

    220/240V-50/60HZ

    2

    B-4(T6360A)

    16(5)A4

    3

    1

    2

    N

    L

    220/240V-50/60HZ

    5

    6

    5

    2

    B-5(T6360A)

    2

    1

    1 2

    6(3)A

    220/240V-50/60HZ

    N

    L

    HT06...

    Mechanical HeatingThermostatFloor HeatingFloor Heating

    HT03...

    Mechanical Heating Thermostat

    03/www.tkbhome.com www.tkbhome.com/04

    HT06HT03

  • TKB60...

    Non-Programming Heating ThermostatFloor HeatingFloor Heating

    Electrical Heating Thermostat

    05/www.tkbhome.com www.tkbhome.com/06

    Introduction

    is used installation of direct wall and have a wide range of

    controlling temperature. Fool type control interface is easy to use.

    LED indicates the working state and it is easy for users to understand

    operation of the thermostat. Built-in sensor measures temperature

    and external sensor makes the over-temperature protection.

    Application

    It is applicable to the heating system of the temperature automatic

    controlling and provides users with a comfortable, safe,

    energy-saving and high standard heating environment.

    Technical Date

    Voltage

    Current load

    Power waste

    Range of temperature

    Ambient temperature

    Protective casing

    External sensor

    Housing material

    Installation height

    230VAC 50/60Hz 24VAC Option

    16A

  • TKB60...

    Non-Programming Heating ThermostatFloor HeatingFloor Heating

    Electrical Heating Thermostat

    05/www.tkbhome.com www.tkbhome.com/06

    Introduction

    is used installation of direct wall and have a wide range of

    controlling temperature. Fool type control interface is easy to use.

    LED indicates the working state and it is easy for users to understand

    operation of the thermostat. Built-in sensor measures temperature

    and external sensor makes the over-temperature protection.

    Application

    It is applicable to the heating system of the temperature automatic

    controlling and provides users with a comfortable, safe,

    energy-saving and high standard heating environment.

    Technical Date

    Voltage

    Current load

    Power waste

    Range of temperature

    Ambient temperature

    Protective casing

    External sensor

    Housing material

    Installation height

    230VAC 50/60Hz 24VAC Option

    16A

  • Technical Data

    Introduction

    TKB430 is used for 2-position control with on/off output for

    the control the temperature by means of an NTC sensor

    placed externally or internally in the thermostat.

    The thermostat acquires the actual temperature with its

    built-in sensor or floor sensor, and the heating contact will

    close when the room temperature falls below the

    selected setpoint.

    85~265VAC, 50/60Hz.

    +5℃~+45℃

    16A/3A

  • Technical Data

    Introduction

    TKB430 is used for 2-position control with on/off output for

    the control the temperature by means of an NTC sensor

    placed externally or internally in the thermostat.

    The thermostat acquires the actual temperature with its

    built-in sensor or floor sensor, and the heating contact will

    close when the room temperature falls below the

    selected setpoint.

    85~265VAC, 50/60Hz.

    +5℃~+45℃

    16A/3A

  • For the control of warm-water (floor) heating systems and direct

    electric heating systems used in Commercial buildings,

    Residential buildings, Light industrial buildings...

    E6 is programming heating thermostat with LCD screen,which has manual

    mode and clock-controlled programme mode.

    The thermostat is recommended for the control of electric heating

    device or on/off valve actuator in hydronic underfloor heating.

    7 6 5 4 3 2 1

    E62.123

    E62.116

    E62.113

    7 6 5 4 3 2 1

    7 6 5 4 3 2 1

    t℃

    t℃

    L1 N1 N L

    7 6 5 4 3 2 1

    t℃

    L1 N1 N L

    3A

    16A

    N LL1

    3A

    Main control

    circuit

    3A

    Sensor

    Sensor

    Sensor

    Potential-free

    output

    Technical Data

    Introduction

    Application

    Voltage

    Power comsumption

    Setting range

    External limitation

    Switch differential

    Ambient temperature

    Protective housing

    Housing material

    220V/230V

    2W

    5~55℃(Can adjust to:5-90℃)

    5...60℃(Factory setting:35℃)

    0.5-10℃ adjustabie(Factory setting:±1℃)

    -5~50℃

    IP20

    Anti-flammable PC

    Wiring Diagram

    Selection Table

    ModelLoading

    (PCS/Carton)Current

    E62.113

    E62.123

    E62.116

    3A

    3A

    16A

    64

    64

    64

    E6...

    Heating Thermostat with Day Programming

    Sensor

    Built-in sensor

    Built-in sensor

    Built-in & floor sensor

    Heating Thermsotat with LCD Screen

    Introduction

    HT01 Heating Thermostat is applied for Water Heating

    System and Electric Heating System. We take high quality raw

    materials, and produce and inspect strictly so as to make

    products steady and precise.

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Voltage

    Room temp.range

    Floor over-heating protection

    Load

    Accuracy

    Housing material

    Technical Data

    230VAC ±10%, 50/60HZ

    5~30℃

    30~80℃

    3A/16A

    ±0.5℃

    ABS+PC fire-resistant

    Backight: white, blue, green

    Network: Modbus

    Wiring Diagram

    Selection Table

    Part

    HT01-3R

    HT01-16R

    HT01-16RF

    Current

    3A

    16A

    16A

    Sensor

    Built-in sensor

    Built-in sensor

    Built-in & floor sensor

    64

    64

    64

    Loading (PCS/Carton)

    7 6 5 4 3 2 1

    SENSOR

    3600W/16AL N N L

    230V/AC

    60

    Floor HeatingFloor Heating

    11/www.tkbhome.com www.tkbhome.com/12

    HT01...

  • For the control of warm-water (floor) heating systems and direct

    electric heating systems used in Commercial buildings,

    Residential buildings, Light industrial buildings...

    E6 is programming heating thermostat with LCD screen,which has manual

    mode and clock-controlled programme mode.

    The thermostat is recommended for the control of electric heating

    device or on/off valve actuator in hydronic underfloor heating.

    7 6 5 4 3 2 1

    E62.123

    E62.116

    E62.113

    7 6 5 4 3 2 1

    7 6 5 4 3 2 1

    t℃

    t℃

    L1 N1 N L

    7 6 5 4 3 2 1

    t℃

    L1 N1 N L

    3A

    16A

    N LL1

    3A

    Main control

    circuit

    3A

    Sensor

    Sensor

    Sensor

    Potential-free

    output

    Technical Data

    Introduction

    Application

    Voltage

    Power comsumption

    Setting range

    External limitation

    Switch differential

    Ambient temperature

    Protective housing

    Housing material

    220V/230V

    2W

    5~55℃(Can adjust to:5-90℃)

    5...60℃(Factory setting:35℃)

    0.5-10℃ adjustabie(Factory setting:±1℃)

    -5~50℃

    IP20

    Anti-flammable PC

    Wiring Diagram

    Selection Table

    ModelLoading

    (PCS/Carton)Current

    E62.113

    E62.123

    E62.116

    3A

    3A

    16A

    64

    64

    64

    E6...

    Heating Thermostat with Day Programming

    Sensor

    Built-in sensor

    Built-in sensor

    Built-in & floor sensor

    Heating Thermsotat with LCD Screen

    Introduction

    HT01 Heating Thermostat is applied for Water Heating

    System and Electric Heating System. We take high quality raw

    materials, and produce and inspect strictly so as to make

    products steady and precise.

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Voltage

    Room temp.range

    Floor over-heating protection

    Load

    Accuracy

    Housing material

    Technical Data

    230VAC ±10%, 50/60HZ

    5~30℃

    30~80℃

    3A/16A

    ±0.5℃

    ABS+PC fire-resistant

    Backight: white, blue, green

    Network: Modbus

    Wiring Diagram

    Selection Table

    Part

    HT01-3R

    HT01-16R

    HT01-16RF

    Current

    3A

    16A

    16A

    Sensor

    Built-in sensor

    Built-in sensor

    Built-in & floor sensor

    64

    64

    64

    Loading (PCS/Carton)

    7 6 5 4 3 2 1

    SENSOR

    3600W/16AL N N L

    230V/AC

    60

    Floor HeatingFloor Heating

    11/www.tkbhome.com www.tkbhome.com/12

    HT01...

  • Introduction

    is weekly circulation, it is possible to set 6 periods called events

    each day with corresponding pre-set temperatures, also you can

    select "period control mode" or "comfort mode" according to your

    individual requirements.

    The thermostat is recommended for the control of electric

    heating devices or on/off valve actuator used in water-based

    heating systems.

    For the control of warm-water(floor) heating systems and direct

    electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Technical Data

    Voltage

    Sensor

    Power consumption

    Accuracy of temperature measurement

    Limitation range

    Ambient temperature

    Protective housing

    Housing material

    220AC 50/60Hz

    NTC

    2W

    ±1℃

    0 90℃

    -5~50℃

    IP20

    anti-flammable PC

    Wiring Diagram

    Model Current

    HT05.13

    HT05.16

    3A

    16A

    Selection Table

    Programable Thermostat with LCD Screen

    7654321

    NL L1 N1

    X

    AC220V 3/16A Sensor

    Outer

    Sensor

    64

    64

    Built-in sensor

    Built-in & floor sensor

    Loading (PCS/Carton)

    Heating Thermostat with Weekly Programming

    Introduction

    Heating Thermostat with weekly programming adopts the

    latest single-chip computer control technology. It has the high

    reliability and powerful anti-jamming.

    Voltage

    Internal sensor setting range

    Internal sensor measurement range

    External sensor measurement range

    Housing material

    Floor Sensor

    Technical Data

    230VAC ±10% 50/60 Hz(24VAC Optional)

    5-35°C(programmable) (factory setting:25°C)

    0-40°C

    0-90°C(factory setting:50°C)

    Anti-flammable

    Length=3M NTC B=3380 10k@25degrees Celsius(Optional)

    Wiring Diagram

    Selection Table

    Model Current

    HT08H1

    HT08H2

    HT08H3

    3A

    10A

    16A

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Sensor

    Built-in sensor

    Built-in or floor sensor

    Built-in & floor sensor

    60

    60

    60

    Loading (PCS/Carton)

    Heati

    ng F

    loor

    Therm

    osta

    t

    H1 TYPE

    Sensor

    SPST

    3A LOAD

    L N

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    10A LOAD

    Sensor

    H2 TYPE H3 TYPE

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    16A LOAD

    Sensor

    60mm

    50mm

    45.2

    mm

    Floor HeatingFloor Heating

    13/www.tkbhome.com www.tkbhome.com/14

    HT05... HT08...

    HT05 HT08

  • Introduction

    is weekly circulation, it is possible to set 6 periods called events

    each day with corresponding pre-set temperatures, also you can

    select "period control mode" or "comfort mode" according to your

    individual requirements.

    The thermostat is recommended for the control of electric

    heating devices or on/off valve actuator used in water-based

    heating systems.

    For the control of warm-water(floor) heating systems and direct

    electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Technical Data

    Voltage

    Sensor

    Power consumption

    Accuracy of temperature measurement

    Limitation range

    Ambient temperature

    Protective housing

    Housing material

    220AC 50/60Hz

    NTC

    2W

    ±1℃

    0 90℃

    -5~50℃

    IP20

    anti-flammable PC

    Wiring Diagram

    Model Current

    HT05.13

    HT05.16

    3A

    16A

    Selection Table

    Programable Thermostat with LCD Screen

    7654321

    NL L1 N1

    X

    AC220V 3/16A Sensor

    Outer

    Sensor

    64

    64

    Built-in sensor

    Built-in & floor sensor

    Loading (PCS/Carton)

    Heating Thermostat with Weekly Programming

    Introduction

    Heating Thermostat with weekly programming adopts the

    latest single-chip computer control technology. It has the high

    reliability and powerful anti-jamming.

    Voltage

    Internal sensor setting range

    Internal sensor measurement range

    External sensor measurement range

    Housing material

    Floor Sensor

    Technical Data

    230VAC ±10% 50/60 Hz(24VAC Optional)

    5-35°C(programmable) (factory setting:25°C)

    0-40°C

    0-90°C(factory setting:50°C)

    Anti-flammable

    Length=3M NTC B=3380 10k@25degrees Celsius(Optional)

    Wiring Diagram

    Selection Table

    Model Current

    HT08H1

    HT08H2

    HT08H3

    3A

    10A

    16A

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Sensor

    Built-in sensor

    Built-in or floor sensor

    Built-in & floor sensor

    60

    60

    60

    Loading (PCS/Carton)

    Heati

    ng F

    loor

    Therm

    osta

    t

    H1 TYPE

    Sensor

    SPST

    3A LOAD

    L N

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    10A LOAD

    Sensor

    H2 TYPE H3 TYPE

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    16A LOAD

    Sensor

    60mm

    50mm

    45.2

    mm

    Floor HeatingFloor Heating

    13/www.tkbhome.com www.tkbhome.com/14

    HT05... HT08...

    HT05 HT08

  • Heating Thermostat with Weekly Programming

    Introduction

    Heating Thermostat with weekly programming adopts the

    latest single-chip computer control technology. It has the high

    reliability and powerful anti-jamming.

    Voltage

    Internal sensor setting range

    Internal sensor measurement range

    External sensor measurement range

    Housing material

    Floor Sensor

    Technical Data

    230VAC 10% 50/60 Hz(24VAC Optional)

    5-35°C(programmable) (factory setting:25°C)

    0-40°C

    0-90°C(factory setting:50°C)

    Anti-flammable

    Length=3M NTC B=3380 10k@25degrees Celsius(Optional)

    ±

    Wiring Diagram

    Selection Table

    Model Current

    HT09H1

    HT09H2

    HT09H3

    3A

    10A

    16A

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Sensor

    Built-in sensor

    Built-in or floor sensor

    Built-in & floor sensor

    60

    60

    60

    Loading (PCS/Carton)

    Heati

    ng F

    loor

    Therm

    osta

    t

    H1 TYPE

    Sensor

    SPST

    3A LOAD

    L N

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    10A LOAD

    Sensor

    H2 TYPE H3 TYPE

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    16A LOAD

    Sensor

    50mm

    60mm

    E92...

    Touch-screen Programming Thermostat

    Introduction

    Application

    Technical Data

    E92 weekly programming series LCD digital heating thermostat is

    weekly circulation, this heating room thermostat can let you

    set 6 periods with different setted temperature, also you can

    select manual mode or periods programming control mode.

    It is used for controlling electrical heating equipments and

    electric control valve in water-based heating system.

    For the control of warm-water(floor) heating systems and direct

    electric heating systems used in Commercial buildings,

    Residential buildings, Light industrial buildings...

    Wiring Diagram

    Selection Table

    Model Current

    E92.713

    E92.723

    E92.716

    3A

    3A

    16A

    Voltage

    Power consumption

    Setting range

    Limitation range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V 50~60Hz

    2VA

    5...90℃

    (Upper limitation from 35℃-90℃adjustable )

    5...60℃(Factory setting:35℃)

    0.5-10℃adjustable(Factory setting:±1℃ )

    -5~50℃

    IP20

    Anti-flammable PC

    Sensor

    Built-in sensor

    Built-in sensor

    Built-in & floor sensor

    64

    64

    64

    Loading (PCS/Carton)

    7 6 5 4 3 2 1

    E92.713 7 6 5 4 3 2 1

    Sensor

    t℃

    L1 N1 N L

    3A

    E92.716 7 6 5 4 3 2 1

    Sensor

    t℃

    L1 N1 N L

    16A

    E92.723

    Sensor

    t℃

    N LL1

    3A

    3A

    main loop

    potential free

    7 6 5 4 3 2 1

    Floor HeatingFloor Heating

    15/www.tkbhome.com www.tkbhome.com/16

    HT09...

    HT09

  • Heating Thermostat with Weekly Programming

    Introduction

    Heating Thermostat with weekly programming adopts the

    latest single-chip computer control technology. It has the high

    reliability and powerful anti-jamming.

    Voltage

    Internal sensor setting range

    Internal sensor measurement range

    External sensor measurement range

    Housing material

    Floor Sensor

    Technical Data

    230VAC 10% 50/60 Hz(24VAC Optional)

    5-35°C(programmable) (factory setting:25°C)

    0-40°C

    0-90°C(factory setting:50°C)

    Anti-flammable

    Length=3M NTC B=3380 10k@25degrees Celsius(Optional)

    ±

    Wiring Diagram

    Selection Table

    Model Current

    HT09H1

    HT09H2

    HT09H3

    3A

    10A

    16A

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrical buildings…

    Application

    Sensor

    Built-in sensor

    Built-in or floor sensor

    Built-in & floor sensor

    60

    60

    60

    Loading (PCS/Carton)

    Heati

    ng F

    loor

    Therm

    osta

    t

    H1 TYPE

    Sensor

    SPST

    3A LOAD

    L N

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    10A LOAD

    Sensor

    H2 TYPE H3 TYPE

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    16A LOAD

    Sensor

    50mm

    60mm

    E92...

    Touch-screen Programming Thermostat

    Introduction

    Application

    Technical Data

    E92 weekly programming series LCD digital heating thermostat is

    weekly circulation, this heating room thermostat can let you

    set 6 periods with different setted temperature, also you can

    select manual mode or periods programming control mode.

    It is used for controlling electrical heating equipments and

    electric control valve in water-based heating system.

    For the control of warm-water(floor) heating systems and direct

    electric heating systems used in Commercial buildings,

    Residential buildings, Light industrial buildings...

    Wiring Diagram

    Selection Table

    Model Current

    E92.713

    E92.723

    E92.716

    3A

    3A

    16A

    Voltage

    Power consumption

    Setting range

    Limitation range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V 50~60Hz

    2VA

    5...90℃

    (Upper limitation from 35℃-90℃adjustable )

    5...60℃(Factory setting:35℃)

    0.5-10℃adjustable(Factory setting:±1℃ )

    -5~50℃

    IP20

    Anti-flammable PC

    Sensor

    Built-in sensor

    Built-in sensor

    Built-in & floor sensor

    64

    64

    64

    Loading (PCS/Carton)

    7 6 5 4 3 2 1

    E92.713 7 6 5 4 3 2 1

    Sensor

    t℃

    L1 N1 N L

    3A

    E92.716 7 6 5 4 3 2 1

    Sensor

    t℃

    L1 N1 N L

    16A

    E92.723

    Sensor

    t℃

    N LL1

    3A

    3A

    main loop

    potential free

    7 6 5 4 3 2 1

    Floor HeatingFloor Heating

    15/www.tkbhome.com www.tkbhome.com/16

    HT09...

    HT09

  • HT07...

    Technical Data

    Voltage

    Internal sensor setting range

    Internal sensor measurement range

    External sensor measurement range

    Floor Sensor

    230VAC ±10% 50/60 Hz(24VAC Optional)

    5-35°C(programmable)(factory setting: 25°C)

    0-40°C

    0-90°C(factory setting: 50°C)

    Length=3M NTC B=3380 10k@25degrees Celsius(Optional)

    Wiring Diagram

    Selection Table

    Heati

    ng F

    loor

    Therm

    osta

    t

    H1 TYPE

    Sensor

    SPST

    3A LOAD

    L N

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    10A LOAD

    Sensor

    H2 TYPE H3 TYPE

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    16A LOAD

    Sensor

    60mm

    50mm

    45.2

    mm

    Model Current

    HT07H1

    HT07H2

    HT07H3

    3A

    10A

    16A

    Sensor

    Built-in sensor

    Built-in sensor or floor sensor

    Built-in & floor sensor

    60

    60

    60

    Loading (PCS/Carton)

    Introduction

    Application

    weekly programming series LCD digital heating thermostat

    is weekly circulation, this heating room thermostat can let you

    set 6 periods with different setted temperature, also you can

    select manual mode or periods programming control mode.

    It is used for controlling electrical heating equipments and

    electric control valve in water-based heating system.

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrial buildings...

    Pencils, pen, and Other Sharp Objects should never be used on your color touch thermostat. These may damage your color touch

    screen. Only use your finger to press the bunons on the screen, Use a soft, damp cloth to clean the screen.

    Care And Use Of Your Thermostat

    Time and Data

    Room Temp.

    Current Mode

    Sub Menu Screen

    Date and Time Setting

    My Program Schedule

    Mode Temp.Pre-set

    Sub Mode Screen

    Comfort Mode

    Economy Mode

    Holiday Mode

    PRG Mode

    Wiring Diagram

    Home Screen

    7 6 5 4 3 2 1

    SENSOR

    3600W/16AL N N L

    230V/AC

    Front130mm

    87m

    m

    Thickness

    31mm 18mm

    50m

    m Mounting Hole

    60mm

    52m

    m

    94mm

    HT10...

    Home﹠Return Button Menu Button Mode Select Button

    Up Button

    Down Button

    OFF Button

    Battery Indicator

    Signal Status

    Floor HeatingFloor Heating

    17/www.tkbhome.com www.tkbhome.com/18

    Touch Screen Programming Thermostat Color Touch Thermostat

    HT07

  • HT07...

    Technical Data

    Voltage

    Internal sensor setting range

    Internal sensor measurement range

    External sensor measurement range

    Floor Sensor

    230VAC ±10% 50/60 Hz(24VAC Optional)

    5-35°C(programmable)(factory setting: 25°C)

    0-40°C

    0-90°C(factory setting: 50°C)

    Length=3M NTC B=3380 10k@25degrees Celsius(Optional)

    Wiring Diagram

    Selection Table

    Heati

    ng F

    loor

    Therm

    osta

    t

    H1 TYPE

    Sensor

    SPST

    3A LOAD

    L N

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    10A LOAD

    Sensor

    H2 TYPE H3 TYPE

    Heati

    ng F

    loor

    Therm

    osta

    t L

    N

    16A LOAD

    Sensor

    60mm

    50mm

    45.2

    mm

    Model Current

    HT07H1

    HT07H2

    HT07H3

    3A

    10A

    16A

    Sensor

    Built-in sensor

    Built-in sensor or floor sensor

    Built-in & floor sensor

    60

    60

    60

    Loading (PCS/Carton)

    Introduction

    Application

    weekly programming series LCD digital heating thermostat

    is weekly circulation, this heating room thermostat can let you

    set 6 periods with different setted temperature, also you can

    select manual mode or periods programming control mode.

    It is used for controlling electrical heating equipments and

    electric control valve in water-based heating system.

    For the control of warm-water(floor) heating systems and

    direct electric heating systems used in Commercial buildings,

    Residential buildings, Light industrial buildings...

    Pencils, pen, and Other Sharp Objects should never be used on your color touch thermostat. These may damage your color touch

    screen. Only use your finger to press the bunons on the screen, Use a soft, damp cloth to clean the screen.

    Care And Use Of Your Thermostat

    Time and Data

    Room Temp.

    Current Mode

    Sub Menu Screen

    Date and Time Setting

    My Program Schedule

    Mode Temp.Pre-set

    Sub Mode Screen

    Comfort Mode

    Economy Mode

    Holiday Mode

    PRG Mode

    Wiring Diagram

    Home Screen

    7 6 5 4 3 2 1

    SENSOR

    3600W/16AL N N L

    230V/AC

    Front130mm

    87m

    m

    Thickness

    31mm 18mm

    50m

    m Mounting Hole

    60mm

    52m

    m

    94mm

    HT10...

    Home﹠Return Button Menu Button Mode Select Button

    Up Button

    Down Button

    OFF Button

    Battery Indicator

    Signal Status

    Floor HeatingFloor Heating

    17/www.tkbhome.com www.tkbhome.com/18

    Touch Screen Programming Thermostat Color Touch Thermostat

    HT07

  • E8.2...

    Wireless Room Thermostat with Batteries

    Technical Data

    Introduction

    E8.2 touch screen thermostat, AL-MG alloy/Plastic

    upper cover with large LCD screen with white backlight,

    Wall surface mounted.

    Features

    Radio frequency 433MHz, one-to-one or many-to-one,

    a variety of solutions.

    A potential-free connected controlling port.

    Special for underfloor heating or boiler heating.

    Two section 5 batteries to ensure the power of one heating season.

    Adopt magnetic latching relay, low power consumption.

    24 events every day, 7-day programmable controller.

    Energy-saving temperature and comfort temperature selectable.

    Parameter memory, anti-frozen function.

    Key-lock function, low battery indicator.

    >

    >

    >

    >

    >

    >

    >

    >

    >

    Power supply

    Wireless frequency

    Measuring range

    Setting range

    Switching differential

    Factory setting

    Sensor

    Measuring quantity

    Potential free output

    DC3V, 2 section of batteries(size AA)

    433MHz

    0...95°C

    5...90°C

    0.5~5°Cadjustable

    1°C

    Internal NTC sensor

    1pcs

    Max5A(AC220V resistance load)

    Selection Table

    Model Number ApplicationHousing color

    Wiring Diagram

    E8.2RF

    E8.2RF

    Ivory

    Silver

    433MHz frequency output

    433MHz frequency output

    E8.583RF

    many to one wireless central controller

    E8.2RF E8.2RF E8.2RF E8.2RF E8.2RF

    E8.4..RF...

    Wireless Receiver

    E8.416RF

    exte

    rnal te

    mpera

    ture

    limita

    tion s

    ensor

    heating cable≤3200W

    t℃

    E8.413RF 7 6 5 4 3 2 1

    sensor

    t℃

    L1 N1 N L

    3A

    E8.416RF 7 6 5 4 3 2 1

    sensor

    t℃

    L1 N1 N L

    16A

    E8.423RF 7 6 5 4 3 2 1

    sensor

    t℃

    N LL1

    3A

    3Apotential

    free

    main loop

    Introduction

    E8.4..RF one to one wireless receiver with independent selectable

    temperature limitation control circuit, it is used for electrical equipments

    control in electric heating, and electrical valve control in water-based

    heating system.

    Voltage

    Power consumption

    Transmission frequency

    Transmission distance

    Limitation temperature

    Limitation switching differential

    Ambient temperature

    Protective housing

    Housing material

    Technical Data

    AC230V 50~60Hz

    2VA

    433MHz

    200m

    30、40、55°Cselectable(Factory setting:30°C)

    -2°C

    -5~50°C

    IP20

    Anti-flammable PC

    Wiring Diagram

    Selection Table

    Model Number Control MethodCurrent

    E8.413RF

    E8.423RF

    E8.416RF

    E8.583RF

    3A

    3A

    16A

    Max.3A

    1 loop receiving, temperature control and limitation

    1 loop receiving, temperature control and limitationpotential free output

    1 loop receiving, temperature control and limitation

    Many to one wireless receiver(max.8 loops)

    Floor HeatingFloor Heating

    19/www.tkbhome.com www.tkbhome.com/20

  • E8.2...

    Wireless Room Thermostat with Batteries

    Technical Data

    Introduction

    E8.2 touch screen thermostat, AL-MG alloy/Plastic

    upper cover with large LCD screen with white backlight,

    Wall surface mounted.

    Features

    Radio frequency 433MHz, one-to-one or many-to-one,

    a variety of solutions.

    A potential-free connected controlling port.

    Special for underfloor heating or boiler heating.

    Two section 5 batteries to ensure the power of one heating season.

    Adopt magnetic latching relay, low power consumption.

    24 events every day, 7-day programmable controller.

    Energy-saving temperature and comfort temperature selectable.

    Parameter memory, anti-frozen function.

    Key-lock function, low battery indicator.

    >

    >

    >

    >

    >

    >

    >

    >

    >

    Power supply

    Wireless frequency

    Measuring range

    Setting range

    Switching differential

    Factory setting

    Sensor

    Measuring quantity

    Potential free output

    DC3V, 2 section of batteries(size AA)

    433MHz

    0...95°C

    5...90°C

    0.5~5°Cadjustable

    1°C

    Internal NTC sensor

    1pcs

    Max5A(AC220V resistance load)

    Selection Table

    Model Number ApplicationHousing color

    Wiring Diagram

    E8.2RF

    E8.2RF

    Ivory

    Silver

    433MHz frequency output

    433MHz frequency output

    E8.583RF

    many to one wireless central controller

    E8.2RF E8.2RF E8.2RF E8.2RF E8.2RF

    E8.4..RF...

    Wireless Receiver

    E8.416RF

    exte

    rnal te

    mpera

    ture

    limita

    tion s

    ensor

    heating cable≤3200W

    t℃

    E8.413RF 7 6 5 4 3 2 1

    sensor

    t℃

    L1 N1 N L

    3A

    E8.416RF 7 6 5 4 3 2 1

    sensor

    t℃

    L1 N1 N L

    16A

    E8.423RF 7 6 5 4 3 2 1

    sensor

    t℃

    N LL1

    3A

    3Apotential

    free

    main loop

    Introduction

    E8.4..RF one to one wireless receiver with independent selectable

    temperature limitation control circuit, it is used for electrical equipments

    control in electric heating, and electrical valve control in water-based

    heating system.

    Voltage

    Power consumption

    Transmission frequency

    Transmission distance

    Limitation temperature

    Limitation switching differential

    Ambient temperature

    Protective housing

    Housing material

    Technical Data

    AC230V 50~60Hz

    2VA

    433MHz

    200m

    30、40、55°Cselectable(Factory setting:30°C)

    -2°C

    -5~50°C

    IP20

    Anti-flammable PC

    Wiring Diagram

    Selection Table

    Model Number Control MethodCurrent

    E8.413RF

    E8.423RF

    E8.416RF

    E8.583RF

    3A

    3A

    16A

    Max.3A

    1 loop receiving, temperature control and limitation

    1 loop receiving, temperature control and limitationpotential free output

    1 loop receiving, temperature control and limitation

    Many to one wireless receiver(max.8 loops)

    Floor HeatingFloor Heating

    19/www.tkbhome.com www.tkbhome.com/20

  • Air Conditioning Air Conditioning

    TKB101...

    Mechanical FCU Thermostat

    Technical Data

    Introduction

    TKB101 FCU thermostat are usually used on the commercial,

    industrial and civil constructions, which can control the fan coil of

    air-conditioning, water valve and wind valve ect.

    It can make the temperature balance in the setting range in the

    location, and all switches are manual switch, very simple to

    manipulate.

    Temperature controlling range

    Working voltage

    Current load

    Sensing element

    Temperature differential

    Storing environment

    Housing material

    External dimension

    Installation

    5℃~30℃

    230VAC±10%, 50Hz/60Hz

    >

    >

    >

    >

    Attractive modern styling

    Adjustable heating/cooling mode control

    Adjustable manual 3-speed:LM.H

    Standard junction box mounting

    2-pipes

    Restart

    Features

    Wiring Diagram

    21/www.tkbhome.com www.tkbhome.com/22

    AC220V

    L N

    TOH

    NEC

    LOW FAN

    N

    NV

    OLTN

  • Air Conditioning Air Conditioning

    TKB101...

    Mechanical FCU Thermostat

    Technical Data

    Introduction

    TKB101 FCU thermostat are usually used on the commercial,

    industrial and civil constructions, which can control the fan coil of

    air-conditioning, water valve and wind valve ect.

    It can make the temperature balance in the setting range in the

    location, and all switches are manual switch, very simple to

    manipulate.

    Temperature controlling range

    Working voltage

    Current load

    Sensing element

    Temperature differential

    Storing environment

    Housing material

    External dimension

    Installation

    5℃~30℃

    230VAC±10%, 50Hz/60Hz

    >

    >

    >

    >

    Attractive modern styling

    Adjustable heating/cooling mode control

    Adjustable manual 3-speed:LM.H

    Standard junction box mounting

    2-pipes

    Restart

    Features

    Wiring Diagram

    21/www.tkbhome.com www.tkbhome.com/22

    AC220V

    L N

    TOH

    NEC

    LOW FAN

    N

    NV

    OLTN

  • Air Conditioning

    E51...

    FCU Thermostat with LCD

    Introduction

    Technical Data

    Application

    E51 Multi-functional intelligent digital thermostats are designed for

    controlling a 3-speed fan and an on/off valve actuator in 2-pipe/4-pipe

    FCU system, to meet up the adjusted indoor temperature.

    In conjunction with fans and valves, E51...is designed to

    control the valve in heating or cooling systems to maintain the

    desired set point temperature in Commercial buildings, Residential

    buildings, Light industrial buildings...

    Voltage

    Load

    Power consumption

    Setting range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V(AC110V/AC24V available)

    3A

    2W

    5 45

    ±1 , Adjustable

    5-45

    IP20

    Anti-flammable PC

    ~ ℃

    Wiring Diagram

    E51.42 E51.50

    Selection Table

    Model Number Backlight

    E51.42

    E51.50

    Yes

    Yes

    Auto,Low,Mid,Hi

    Auto,Low,Mid,Hi

    Fan control

    Heating/Cooling

    Heating/Cooling

    System control

    2-pipe FCU system

    4-pipe FCU system

    ApplicationLoading

    (PCS/Carton)

    64

    64

    Air Conditioning

    E91...

    Touch-Screen FCU Thermostats

    Introduction

    Application

    In conjunction with fans and valves, E91... is designed to control

    the valve in heating or cooling systems to maintain the desired

    setpoint temperature in Commercial buildings, Residential buildings,

    Light industrial buildings...

    Technical Data

    Voltage

    Load

    Power consumption

    Setting range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V (AC110V/AC24V available)

    3A

    3.5W

    5 35

    ±0.5K

    -5 50

    IP20

    Self-extinguishing PC

    ℃~ ℃

    ℃~ ℃

    Wiring Diagram

    Selection Table

    Model Number Backlight

    E91.42

    E91.50

    Yes

    Yes

    Auto,Low,Mid,Hi

    Auto,Low,Mid,Hi

    Fan control

    Heating/Cooling

    Heating/Cooling

    System control

    2-pipe FCU system

    4-pipe FCU system

    ApplicationLoading

    (PCS/Carton)

    64

    64

    E91.42 E91.50

    E91 Multi-functional intelligent digital thermostats are designed for

    controlling a 3-speed fan and an on/off valve actuator in 2-pipe/4-pipe

    FCU system, to meet up the adjusted indoor temperature.

    23/www.tkbhome.com www.tkbhome.com/24

  • Air Conditioning

    E51...

    FCU Thermostat with LCD

    Introduction

    Technical Data

    Application

    E51 Multi-functional intelligent digital thermostats are designed for

    controlling a 3-speed fan and an on/off valve actuator in 2-pipe/4-pipe

    FCU system, to meet up the adjusted indoor temperature.

    In conjunction with fans and valves, E51...is designed to

    control the valve in heating or cooling systems to maintain the

    desired set point temperature in Commercial buildings, Residential

    buildings, Light industrial buildings...

    Voltage

    Load

    Power consumption

    Setting range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V(AC110V/AC24V available)

    3A

    2W

    5 45

    ±1 , Adjustable

    5-45

    IP20

    Anti-flammable PC

    ~ ℃

    Wiring Diagram

    E51.42 E51.50

    Selection Table

    Model Number Backlight

    E51.42

    E51.50

    Yes

    Yes

    Auto,Low,Mid,Hi

    Auto,Low,Mid,Hi

    Fan control

    Heating/Cooling

    Heating/Cooling

    System control

    2-pipe FCU system

    4-pipe FCU system

    ApplicationLoading

    (PCS/Carton)

    64

    64

    Air Conditioning

    E91...

    Touch-Screen FCU Thermostats

    Introduction

    Application

    In conjunction with fans and valves, E91... is designed to control

    the valve in heating or cooling systems to maintain the desired

    setpoint temperature in Commercial buildings, Residential buildings,

    Light industrial buildings...

    Technical Data

    Voltage

    Load

    Power consumption

    Setting range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V (AC110V/AC24V available)

    3A

    3.5W

    5 35

    ±0.5K

    -5 50

    IP20

    Self-extinguishing PC

    ℃~ ℃

    ℃~ ℃

    Wiring Diagram

    Selection Table

    Model Number Backlight

    E91.42

    E91.50

    Yes

    Yes

    Auto,Low,Mid,Hi

    Auto,Low,Mid,Hi

    Fan control

    Heating/Cooling

    Heating/Cooling

    System control

    2-pipe FCU system

    4-pipe FCU system

    ApplicationLoading

    (PCS/Carton)

    64

    64

    E91.42 E91.50

    E91 Multi-functional intelligent digital thermostats are designed for

    controlling a 3-speed fan and an on/off valve actuator in 2-pipe/4-pipe

    FCU system, to meet up the adjusted indoor temperature.

    23/www.tkbhome.com www.tkbhome.com/24

  • Air Conditioning Air Conditioning

    Introduction

    Technical Data

    Application

    TKB50 FCU thermostat acquires the room temperature with its built-in

    NTC sensor.

    The heating contact will close when the room temperature falls below

    the selected setpoint in heating mode.

    The cooling contact will close when the room temperature exceeds

    the selected setpoint in cooling mode.

    In conjunction with fans and valves, TKB50...is designed to control

    the valve in heating or cooling systems to maintain the desired

    setpoint temperature in Commercial buildings, Residential buildings,

    Light industrial buildings...

    Voltage

    Load

    Power consumption

    Setting range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V(AC110V/AC24V available)

    3A

    2W

    4 45

    ±0.5K

    -5 50

    IP20

    Self-extinguishing PC

    ℃~ ℃

    ℃~ ℃

    Wiring Diagram

    Model Number Backlight

    TKB50.42L

    TKB50.42LK

    TKB50.42LR

    TKB50.50L

    Yes

    Yes

    Yes

    Yes

    Auto, Low, Mid, Hi

    Auto, Low, Mid, Hi

    Auto, Low, Mid, Hi

    Auto, Low, Mid, Hi

    Fan control

    Heating/Cooling

    Heating/Cooling

    Heating/Cooling

    Heating/Cooling

    System control

    2-pipe FCU system

    2-pipe FCU system

    2-pipe FCU system

    4-pipe FCU system

    ApplicationLoading

    (PCS/Carton)

    64

    64

    64

    64

    Selection Table

    Wiring Diagram

    Technical Data

    Voltage

    Current

    Thermostatic range

    Element of sensorial temperature

    Temperature controlling precision

    Shipment stock temperature

    Housing material

    Surface size

    TKB301...LCD air-conditioning thermostats are always used on the

    business, industrial and civil constructions, which can control the

    fan coil of air-conditioning, water valve and wind valve etc.

    Introduction

    230VAC 10 50Hz/60Hz

    3A

    5 35

    temperature sensitive resistance

    ±1

    temperature(-5 55 ), relevant humidity (RH

  • Air Conditioning Air Conditioning

    Introduction

    Technical Data

    Application

    TKB50 FCU thermostat acquires the room temperature with its built-in

    NTC sensor.

    The heating contact will close when the room temperature falls below

    the selected setpoint in heating mode.

    The cooling contact will close when the room temperature exceeds

    the selected setpoint in cooling mode.

    In conjunction with fans and valves, TKB50...is designed to control

    the valve in heating or cooling systems to maintain the desired

    setpoint temperature in Commercial buildings, Residential buildings,

    Light industrial buildings...

    Voltage

    Load

    Power consumption

    Setting range

    Switching differential

    Ambient temperature

    Protective housing

    Housing material

    AC230V(AC110V/AC24V available)

    3A

    2W

    4 45

    ±0.5K

    -5 50

    IP20

    Self-extinguishing PC

    ℃~ ℃

    ℃~ ℃

    Wiring Diagram

    Model Number Backlight

    TKB50.42L

    TKB50.42LK

    TKB50.42LR

    TKB50.50L

    Yes

    Yes

    Yes

    Yes

    Auto, Low, Mid, Hi

    Auto, Low, Mid, Hi

    Auto, Low, Mid, Hi

    Auto, Low, Mid, Hi

    Fan control

    Heating/Cooling

    Heating/Cooling

    Heating/Cooling

    Heating/Cooling

    System control

    2-pipe FCU system

    2-pipe FCU system

    2-pipe FCU system

    4-pipe FCU system

    ApplicationLoading

    (PCS/Carton)

    64

    64

    64

    64

    Selection Table

    Wiring Diagram

    Technical Data

    Voltage

    Current

    Thermostatic range

    Element of sensorial temperature

    Temperature controlling precision

    Shipment stock temperature

    Housing material

    Surface size

    TKB301...LCD air-conditioning thermostats are always used on the

    business, industrial and civil constructions, which can control the

    fan coil of air-conditioning, water valve and wind valve etc.

    Introduction

    230VAC 10 50Hz/60Hz

    3A

    5 35

    temperature sensitive resistance

    ±1

    temperature(-5 55 ), relevant humidity (RH

  • Air Conditioning Air Conditioning

    TKB400...

    FCU Thermostat with LCD

    Technical Data

    Voltage

    Temperature controlling range

    Standard load

    Power consumption

    Sensing element

    Temperature controlling precision

    Transportation & storage environment temperature

    TKB400... thermostats are mainly used to control the

    2-pipe & 3-speed fan coil and valve, or 4-pipe & 3-speed fan coil

    and valve in the civi l , commercial and industrial constructions.

    Introduction

    220VAC±10%, 50/60Hz

    5℃~35℃

  • Air Conditioning Air Conditioning

    TKB400...

    FCU Thermostat with LCD

    Technical Data

    Voltage

    Temperature controlling range

    Standard load

    Power consumption

    Sensing element

    Temperature controlling precision

    Transportation & storage environment temperature

    TKB400... thermostats are mainly used to control the

    2-pipe & 3-speed fan coil and valve, or 4-pipe & 3-speed fan coil

    and valve in the civi l , commercial and industrial constructions.

    Introduction

    220VAC±10%, 50/60Hz

    5℃~35℃

  • TKBHome

    www.tkbhome.com

    HEATING THERMOSTATS

    FCU THERMOSTATS

    OEM/ODM SERVICES

    TKB CONTROL SYSTEM LIMITED

    Tel: (86 577) 61787335 Fax: (86 577)61787705

    E-mail:sales@tkbhome http://www.tkbhome.com

    Add: No. 8 Xiqiao Road, Liushi, Yueqing, Zhejiang, China 325604 3YEARSWARRANTY

    ISO9001:2008