HEATING COMPONENTS - Guest Home Page

20
346 HEATING COMPONENTS COMBINATION SINGLE STAGE DUAL GAS VALVE, REDUNDANT REPLACES MANY POPULAR BRANDS SLOW OPENING SINGLE STAGE LP KIT INCLUDED 24 VOLT OPERATOR QUICK CONNECT TERMINALS INLET AND OUTLET PRESSURE TAPS OFF-PILOT-ON PROGRAMMED LIGHTING SEQUENCE FOR STANDING PILOT APPLICATION PILOT COMPRESSION FITTING FOR 1/4 INCH O.D. TUBING *LP kit is included. REPLACES: Single and Dual valve standing pilot controls with rated capacity on natural gas at 130,000 BTU/HR. HONEYWELL: V800 & VR800 WHITE-RODGERS: 36C03-300, 36C03-330, 36C03-400 & 36C03-433 ITT GENERAL: B57RA68, B57RF68, B57RH161, B59R02 & B59R06 ROBERTSHAW: 700-400, 700-402 & 700-406 STEVECO: 215-508 SIZE (in.) FOR USE WITH GAS TYPE CAPACITY 1000 BTU’s PRESS. IN. W.C. P/N NAT. L.P. 1/2 x 3/4 YES YES* 130 3.5 P681-1501* P465

Transcript of HEATING COMPONENTS - Guest Home Page

346

HEATING COMPONENTS

COMBINATION SINGLE STAGE DUAL GAS VALVE, REDUNDANT• REPLACES MANY POPULAR BRANDS

• SLOW OPENING

• SINGLE STAGE

• LP KIT INCLUDED

• 24 VOLT OPERATOR

• QUICK CONNECT TERMINALS

• INLET AND OUTLET PRESSURE TAPS

• OFF-PILOT-ON PROGRAMMED LIGHTING SEQUENCE FOR STANDING PILOTAPPLICATION

• PILOT COMPRESSION FITTING FOR 1/4 INCH O.D. TUBING

*LP kit is included.

REPLACES: Single and Dual valve standing pilot controls with rated capacity on natural gas at 130,000 BTU/HR.

HONEYWELL: V800 & VR800WHITE-RODGERS: 36C03-300, 36C03-330, 36C03-400 & 36C03-433ITT GENERAL: B57RA68, B57RF68, B57RH161, B59R02 & B59R06

ROBERTSHAW: 700-400, 700-402 & 700-406STEVECO: 215-508

SIZE (in.)FOR USE WITH GAS TYPE CAPACITY

1000 BTU’sPRESS.IN. W.C.

P/NNAT. L.P.

1/2 x 3/4 YES YES* 130 3.5 P681-1501*

P465

347

HEATING COMPONENTSCOMBINATION GAS CONTROLS

COMBINATION DUAL VALVE GAS CONTROLS

• MANUAL MAIN ANDPILOT GAS SHUTOFF

• NATURAL GAS

• PILOT OUTLET WITHADJUSTMENT

• OUTLET GASPRESSURE TAP

• 24 VOLT OPERATOR

• PRESSUREREGULATOR

• HEAT MOTOR GIVES TIME DELAY

• SIZE 1/2′ x 3/4′, HAS PRESSURE REGULATOR, USE WITHNATURAL GAS, PRESSURE SET AT. 3.5 @125M

• CAPACITY: 164,000 BTU’s

• NON 100% SHUTOFF

• INCLUDES 3/4′ x 1/2′ REDUCER BUSHING

P/N: EF53CK198

P469

SIZE(in.)

PRESSREG.

USE WITHCAPACITY1000 BTU’s

100%SHUT-OFF

P/NNAT. L.P.

/2 x 1/2 YES YES - 225 NO EF33CB181/4 x 3/4 YES - YES 486 YES EF53CK248

• MANUAL MAIN AND PILOTGAS SHUTOFF

• PILOT GAS OUTLET WITHADJUSTMENT

• OUTLET GAS PRESSURETAP

• 24 VOLT OPERATOR

• AUTO PILOT SHUTOFFAND PRESSUREREGULATION AS NOTED

• PRESSURE SET AT:3.5 C& 150M EF33CB181 11@ 125M EF53CK248

P468

*Kit contains EF53CK188 VALVE, Blankoff plate for converting to LPgas applications and 3/4’ to 1/2’ reducer bushing.

†Slow Opening

SIZE(in.)

PRESSREG.

USENAT.

WITHL.P.

100%SHUTOFF

P/N

1/2 x 3/4 YES YES - NO EF53CK1851/2 x 3/4 YES YES YES YES EF680006*1/2 x 1/2 YES YES - NO EF53CK198†1/2 x 1/2 NO - YES YES EF53CK2081/2 x 1/2 YES YES - YES EF53CK205†

• MANUAL MAIN ANDPILOT GAS SHUTOFF

• PILOT GAS OUTLETWITH ADJUSTMENT

• OUTLET GAS PRESSURETAP

• 24 VOLT OPERATOR

• AUTO PILOT SHUTOFFAND PRESSUREREGULATION AS NOTED

• CAPACITY: 240,000 BTU’s

• PRESSURE SET AT: 3.5@ 125M

P467

SIZE(in.)

USE w/(TYPE GAS)

CAPACITY1000 BTU’s

PRESS.SET AT

P/N

1/2 x 3/4 NAT. 125 3.5 @ 110M EF32CWI83*1/2 x 3/4 NAT. 140 3.5 EF32CWI90

• DUAL MAIN ELECTRIC VALVES - REDUNDANT

• MANUAL MAIN GAS SHUTOFF

• OUTLET GAS PRESSURE TAP (EF32CW183)

• INLET & OUTLET GAS PRESSURE TAPS (EF32CW190)

• PRESSURE REGULATOR

• PILOT GAS ADJUSTMENT.

• I.I.D. SYSTEM APPLICABLE

• 24 VOLT OPERATOR

• PICK AND HOLD OPERATION.P470

348

HEATING COMPONENTSCOMBINATION DUAL VALVE GAS CONTROLS

• SINGLE STAGE -REDUNDANT

• SLOW OPENING

• 24 VOLT OPERATOR

• PRESSURE REGULATOR

• PILOT GAS ADJUSTMENT

SIZE(in.)

USE WITHCAPACITY

PRESS. IN. W.C. P/NNAT. L.P. 1000 BTU’s

1/2 x 3/4 YES - 130 3.5 EF32CB212

P471

• DUAL MAIN ELECTRICVALVES - REDUNDANT

• I.I.D. SYSTEMAPPLICABLE

• 24 VOLT OPERATOR

• OUTLET GAS PRESSURETAP

• SOLENOID COILS EASILYREPLACED

• PRESSURE REGULATOR

• NATURAL GAS

• SIZE 1/2′ x 3/4′• PRESSURE SET AT: 3.5

@ 125M

• CAPACITY 200,000 BTU’s

P/N: EF33CZ206

P472

P473

• DUAL MAIN ELECTRICVALVES - REDUNDANT

• MANUAL MAIN GASSHUTOFF

• 24 VOLT OPERATOR

• ADJUSTABLE PILOT GASFLOW

• OUTLET GAS PRESSURETAP

• PRESSURE REGULATOR

• NATURAL GAS

• I.I.D. SYSTEM APPLICABLE

NOTE: Package includes EF32CB210 valve and 3/4 to 1/2reducer bushing.

SIZE(in.)

CAPACITY1000 BTU’s

PRESS.SET AT

P/N

1/2 x 3/4 250 3.5 EF680007

SIMILAR MODELS TO RCD P/N EF33CZ206 WITH SLIGHTCHANGES:

• SIZE 1/2′ x 1/2′

• CAPACITY 179,000 BTU’s

• SOLENOID COILS COVERED

• IGNITER MOUNTS NEXT TO COILS

P/N: EF33CZ209

P/N: EF33CZ210

• SINGLE STAGE -REDUNDANT

• 24 VOLT OPERATOR

• PRESSURE REGULATOR

• USE WITH G67 ELECTRONICIGNITION

SIZE(in.)

USE WITH CAPACITY1000 BTU’s

PRESS.IN. W.C.

P/NNAT. L. P.

1/2 x 3/4 YES - 175 3.5 EF33CZ213

P474

*Special pilot porting for zip tube ignition..

SIZE(in.)

CAPACITY1000 BTU’s

PRESS.SET AT

SYSTEM P/N

1/2 x 1/2 200 3.5 @ 125M I.I.D. EF32CB1953/4 x 3/4 335 3.5 @ 110M I.I.D. EF34CW245

• DUAL MAIN ELECTRICVALVES - REDUNDANT

• MANUAL MAIN GASSHUTOFF

• I.I.D. SYSTEMAPPLICABLE

• PILOT GAS ADJUSTMENT

• PRESSURE REGULATOR

• OUTLET GAS PRESSURETAP

• NATURAL GAS

• 24 VOLT OPERATOR

P475

349

HEATING COMPONENTSCOMBINATION TWO STAGE GAS CONTROLS

SIZE(in.)

USEWITH

CAP.1000

BTU’s

PRESS.IN. W.C.

100%SHUT-OFF

P/NNAT. L.P. LO HI

1/2 x 1/2 - YES 225 2.2 11.0 NO EF33CW1863/4 x 3/4 YES - 335 1.3 3.5 NO EF6800163/4 x 3/4 YES - 335 .9 3.5 YES EF34CW245

P476

• PRE-SELECTED FIRSTSTAGE FIRING RATE

• ADJUSTABLE HIGH FIRERATE

• 24 VOLT OPERATOR• MANUAL MAIN GAS

SHUTOFF• PILOT GAS ADJUSTMENT• OUTLET GAS PRESSURE

TAP• PRESSURE REGULATOR

SIZE(in.)

USE WITH CAP.1000

BTU’s

PRESS.IN. W.C. P/N

NAT. L.P. LO HI3/4 x 3/4 - YES 335 3.4 11.0 EF33CW289

P477

• INTERNAL PRESSURESWITCH

• DUAL MAIN ELECTRICVALVES - REDUNDANT

• PRE-SELECTED FIRST• STAGE FIRING RATE• 24 VOLT OPERATOR• MANUAL MAIN GAS

SHUTOFF• PILOT GAS ADJUSTMENT• OUTLET GAS PRESSURE

TAP• PRESSURE REGULATOR• I.I.D. SYSTEM

APPLICABLE

SIZE(in.)

USE WITH CAP.1000

BTU’s

PRESS.IN. W.C. P/N

NAT. L.P. LO Hi3/4 x 3/4 YES - 250 1.3 3.5 EF33CB2651/2 x 1/2 - YES 324 2.2 11.0 EF33CB2093/4 x 3/4 YES - 335 1.5 3.4 EF33CB2653/4 x 3/4 - YES 335 2.2 11.0 EF33CB268

• DUAL MAIN ELECTRICVALVES - REDUNDANT

• PRE-SELECTED FIRSTSTAGE FIRING RATE

• 24 VOLT OPERATOR• MANUAL MAIN GAS

SHUTOFF• PILOT GAS ADJUSTMENT• OUTLET GAS PRESSURE

TAP• PRESSURE REGULATOR• I.I.D. SYSTEM APPLICABLEP478

SIZE(in.)

USE WITH CAP.1000

BTU’s

PRESS.IN. W.C. P/N

NAT. L.P. LO Hi1/2 x 3/4 YES - 110 3.5 1.6 EF33CZ2551/2 x 3/4 - YES 195 10.5 4.8 EF33CZ256

• DUAL MAIN ELECTRICVALVES - REDUNDANT

• PRE-SELECTED FIRSTSTAGE FIRING RATE

• 24 VOLT OPERATOR• MANUAL MAIN GAS

SHUTOFF• OUTLET GAS PRESSURE

TAP• PRESSURE REGULATOR• I.I.D. SYSTEM

APPLICABLEP479

P/N P681-VR8345MUniversal Electronic Ignition Gas Valve• CONTROL INCLUDES MANUAL

VALVE, TWO AUTOMATIC OPERA-TORS, PRESSURE REGULATORS,PILOT ADJUSTMENT, PILOT PLUGAND IGNITION ADAPTER.

• HIGHEST CAPACITY (415,000 BTUMAX. REG., NG) OF ANY ELEC-TRONIC IGNITION VALVE IN THEINDUSTRY.

• REPLACES VIRTUALLY ANY IP, HIS,OR DSI GAS CONTROL.

• FOR USE WITH NATURAL OR MANU-FACTURED GAS OR LP GAS.

• HONEYWELL P/N: VR8345M4302.

P471

PART NUMBER HONEYWELL PART NUMBERP660-VR83A3500 VR8300A3500P660-VR83A3518 VR8300A3518P660-VR83A4508 VR8300A4508P660-VR83A4516 VR8300A4516

P/N P660-VR83AContinuous Pilot Dual Automatic Valve Combi-nation Gas Controls• CONTROLS INCLUDE SAFETY SHUTOFF,

MANUAL VALVE, TWO AUTOMATIC OPERA-TORS, PRESSURE REGULATOR AND PILOTADJUSTMENT.

• REPLACES OVER 95 PERCENT OF THESTANDING PILOT GAS VALVES; MAXIMUMCAPACITY RATING IS 150% OF THE COM-PETITIVE VALVES.

• MEETS 1979 ANSI STANDARDS FORREDUNDANCY IN GAS VALVE OPERATION.

350

HEATING COMPONENTSBURNER IGNITION SYSTEMS

SMARTVALVE SYSTEM

P4318

P/N P660-Y8610UUniversal Retrofit Intermittent Pilot Gas Burner Ignition System• COMBINES THE MOST UNIVERSAL IGNITION CONTROLS (S8610 IP MODULE &

VR8304M GAS VALVE) INTO THE MOST CAPABLE RETROFIT KIT AVAILABLE.

• SINGLE-ROD OR DUAL-ROD IGNITION AND SENSING SIMPLIFIES INSTALLATIONWITH ONLY ONE LEAD TO WIRE.

• SOPHISTICATED LOCKOUT TIMING ELIMINATES NUISANCE LOCKOUTS.• HONEYWELL P/N: Y8610U3003.

P/N P660-Y8610FRetrofit Intermittent Pilot Gas Burner Ignition System• Y8610F KITS ARE FOR USE WITH NATURAL GAS ONLY: CONTINUE TRIAL FOR IGNI-

TION UNTIL THE PILOT LIGHTS OR THE SYSTEM IS SHUT DOWN MANUALLY.

• COMPLETE KIT FOR CONVERTING STANDING PILOT TO INTERMITTENT PILOT.• NOT 100% SHUTOFF ON PILOT FLAME LOSS; IDEAL FOR MOST NATURAL GAS

SYSTEMS.• HONEYWELL P/N: Y8610F5003.

P4319

P/N P682-SV9501M SmartValve System• COMBINES GAS FLOW AND ELECTRONIC INTERMITTENT PILOT SEQUENCING

FUNCTIONS INTO A SINGLE UNIT.

• SUITABLE FOR A WIDE RANGE OF GAS-FIRED APPLIANCES INCLUDING RESI-DENTIAL FURNACES, ROOFTOP FURNACES, RESIDENTIAL BOILERS, UNITHEATERS, INFRARED HEATERS, AND SPACE HEATERS.

• HONEYWELL P/N: SV9501M2528.

351

HEATING COMPONENTSSINGLE FUNCTION GAS CONTROLS

MANUAL GAS SHUTOFF VALVE

• FAST ACTING SOLENOID

• NATURAL AND L.P. GASES

• HIGH CAPACITY

• 1/4 IN. ELECTRICAL QUICKCONNECTS

*Contains (2) 1/2 x 1/4, (2) 1/4 x 1/8 and (2) 1/2 x 3/8 reducerbushings.

†Contains (2) 1/2 x 1/4 and (2) 1/4 x 1/8 reducer bushings.

SIZE(in.)

PILOT VALVESP/NBTU’s

PER HOURCOIL

VOLTS1/2 x 1/2 329,000 24 EF11CW042*1/2 x 1/2 329,000 115 EF11CW044†

P480

• ALUMINUM BODY

• 1/8 NPT PILOTCONNECTION

FIG. A FIG. B

FIG.SIZE(in.)

(NPT)

PILOTCONN.

OVERALLLENGTH

(in.)

HEIGHT(in.)

P/N

A 1/2 x 1/2 Both Plugged 2.8 3.0 EV44CK047B 3/4 x 3/4 One Plugged 3.1 3.6 EV44CK052

P482 P483

PILOT SHUTOFF VALVE

• MAIN LINE GAS VALVESERVICE

• FAST ACTING SOLENOID

• NATURAL AND L.P. GASES

• HIGH CAPACITY

• 30″ ELECTRICAL LEADS(EXCEPT EF11CW182)

• PILOT SWITCH RECEPTACLE,EXCEPT-.RCD P/N: EF11CW182

SIZE (in.)BTU’s PER

HOURCOIL VOLTS P/N

1/2 x 1/2 340,000 25 EF11CW042*1/2 x 1/2 340,000 25 EF11WH0251/2 x 1/2 329,000 230 EF11CW032†3/4 x 3/4 500,000 25 EF11WK0253/4 x 3/4 500,000 115 EF11WK115

*Contains (2) 1/2 x 1/4, (2) 1/4 x 1/8 and (2) 1/2 x 3/8 reducerbushings.

†Contains (2) 1/2 x 1/4 and (2) 1/4 x 1/8 reducer bushings.

P486

CONNECTIONS: 1/8 NPTx 1/4 COMPRESSIONCOUPLING

TYPE BODY P/NRight Angle Aluminum EV43CR956

P487

352

HEATING COMPONENTSGAS VALVE ACCESSORIES

GAS VALVE CONVERTERS/KITS

GAS PRESSURE REGULATOR

• REGULATOR IS 5 PSI TO4 INCHES WC.

NOTE: Pressure set at 3 inches wc.; however, serviceman should always check cal-ibration at time of installation.

VENDORP/N

PIPE SIZE(IN.)

INPUT CAPACITYNATURAL GAS (BTUH)

P/N

Maxitrol 1/2 RV52 1/2 262,000 EF680009Maxitrol 3/4 RV53 3/4 687,750 EF680010

P488

MODELS WITH TOP ADJUSTED REGULATORS:G60 - MFG P/N: Y71GF-4 . . . . . . . . .P/N: EF39AB009G53. . . . . . . . . . . . . . . . . . . . . . . . . . .P/N: EF39AB010

MODELS WITH BOTTOMADJUSTED REGULATORS:

G96 & G196 . . . . . . . . . . . . . . . . . . . .P/N: EF39AB011

REGULATOR AND GASKET SETUSED TO CONVERT ROBERT-SHAW VH700 & 700 MODEL GASVALVES FROM REGULATEDNATURAL GAS TO REGULATEDL.P. GAS

MFG. P/N: 82446

CONVERTS JOHNSONCONTROL GAS VALVES FROMNATURAL GAS TO REGULATEDL.P. GAS

P/N: 302989-102

HONEYWELL VALVES WITH V5306, VR8200 OR VR8204PRESSURE REGULATORS CAN BE CONVERTED FORREGULATED L.P. GAS SERVICE BY USING THESE KITS.

COMPLETE REGULATOR NEED NOT BE CHANGED.

V5306 - MFG.P/N: 391937 . . . . . . . . . . . . . . . P/N: EF39AB001VR8200, VR8402 -MGF. P/N: 393691 . . . . . . . . . . . . . . . . . . . . . P/N: EF39ZW025

P489

P490

BUSHING

HONEYWELL STEP OPENINGREGULATOR FOR CONVER-SION OF RCD EF33CY254VALVE FROM NATURAL GASSERVICE TO

REGULATED L.P. GAS(11.0- W.C./4.5- W.C.)

MFG. P/N: V5307A117P/N: 58GP305671-101

P492

SPRINGP/N

COLOR SIZERED 3.3″ x .30″

301248-102CONVERTS NOM. 3.5” NAT. TO NOM. 11.0" L.P.

PLAIN 3.0″ x .30″301248-101

CONVERTS NOM. 11.0” LP. TO NOM. 3.5" NAT.

REGULATOR SPRING CON-VERTS W-R MODEL 36C &36E GAS VALVE FROMNATURAL GAS TO REGU-LATED L.P. GAS

RCD 646 & 647 VALVECONVERSIONS

MFG. P/N: 92-0659P/N: EF39ZWO23

P493

1/2″ x 3/4″ NPT FACE BUSHING

• USE TO ADAPT 3/4″ NPTPORTED GAS VALVES FORUSE WHERE 1/2″ NPTPIPING AND MANIFOLDSARE PROVIDED

P/N: CA57AP202P494

353

ORIFICESMAIN BURNER ORIFICES

PILOT ORIFICES

DRILL SIZE P/N DRILL SIZE P/N3/8″ ACROSS FLATS, 11/32 x 32 NST, .31″ LONG

38 (.101) LH32DB038 43 (.089) LH32DB04342 (.093) LH32DB042 53 (.059) LH32DB053

54 (.055) LH32DB0547/16″ ACROSS FLATS, 1/8 x 27 NPT, .50″ LONG

53 (.059) LH32DB060 54 (0.55) LH32DB20341 (.067) LH32DB096 101 (.057) LH32DB20440 (.098) LH32DB098 45 (.082) LH32DB20544 (.086) LH32DB200 56 (.046) LH32DB20655 (.052) LH32DB201 42 (.093) LH32DB20743 (.089) LH32DB202 46 (.081) LH32DB208

9/16″ ACROSS FLATS, 1/4 x 18 NPT, 5/8″ LONG54 (.055) LH32JB055 41 (.096) LH32JB09653 (.059) LH32JB059 38 (.101) LH32JB10152 (.063) LH32JB063 36 (.106) LH32JB10642 (.093) LH32JB093

P495

DRILL SIZE RCD P/N DRILL SIZE P/N9/16″ ACROSS FLATS, 1/4 x 18 NPT, 7/8″ LONG

52 (.063) LH32RQBG31 35 (.110) LH32RQ1107/16″ ACROSS FLATS, 1/8 27 NPT, 7/8″ LONG

56 (.046) LH32JB04655 (.052) LH32JB053 43 (.089) LH32JB08954 (.055) LH32JB056 41 (.096) LH32JB09753 (.059) 68459C53 40 (.098) LH32JB09947 (.078) LH32JB078 37 (.104) LH32JB104

DRILL SIZE P/N I DRILL SIZE P/N9/16″ ACROSS FLATS, 1/4 x 18 NPT, 7/8″ LONG, 495 DIA.

65 (.035) LH32RF035 45 (.082) LH32RF08256 (.046) LH32RF047 44 (.086) LH32RF08655 (.052) LH32RF052 41 (.096) LH32RF09654 (.055) LH32RF055 38 (.101) LH32RF10250 (.070) LH32RF070 33 (.113) LH32RF11349 (.073) LH32RF073 32 (.116) LH32RF116

P500

P501

P496

DRILL SIZE P/N F DRILL SIZE P/N7/16″ ACROSS FLATS, 1/8 x 27 NPT, 7/8″ LONG, DIA. -

55 (0.52) LH32EB053 45 (.082) LH32EB081

ORIFICESIZE

PARTMARKING

TYPEGAS

P/N

WHITE-RODGERS USED WITH “E” SERIES PILOTS.010 10U LP LH39WD010.012 12U LP LH39WD012.018 18U NAT LH39WD018.020 2OU NAT LH39WD020

BDP USED WITH 732, 733, 734 and 740 PILOTS.017 BRIGHT NAT LH39JN001

HONEYWELL USED WITH Q308, Q314, Q345 PILOTS.010 BLACK LP LH32RMO15.018 BRIGHT NAT LH32RMO16.012 BBR12 LP LH32AN012.014 BBR14 NAT LH32AN014

WHITE-RODGERS

BDP

HONEYWELL

P497 P498

P499 ORIFICESIZE

PARTMARKING

TYPEGAS

P/N

GENERAL CONTROLS USED WITH 26T PILOTS.010 .010 LP LH32DB001

ROBERTSHAW USED WITH 2CH PILOTS.010 LP10 LP LH32DB002

ORIFICESIZE

PARTMARKING

TYPEGAS

DIM. (in.) P/N

PENN USED WITH “J” SERIES PILOTS.009 4209 LP 39/64 LH32RN109.009 4709 LP 1-1/32 LH32RN009.011 4711 LP 1-9/64 LH39GB011.018 7218 NAT 39/64 LH39GB019.023 3723 NAT 39/64 LH39GB022

ROBERTSHAW

GENERALCONTROLS

P502

P503 PENNP504

354

FAN, LIMIT CONTROLSLIMIT CONTROLS

FAN CONTROLS

• MANUAL RESET

• FOR LINE OR LOWVOLTAGE CIRCUIT

• DIFFERENTIAL LIMIT25° F

• NON-ADJUSTABLESETTINGS

• ELEMENT LENGTH: 3"

SWITCHTYPE

TEMP. SETTING (°F)P/N

OPENS CLOSESSPST 200 175 HH12AD204

P505

• TEMP SETTING:ADJ. 160-250(HH127ZA008)(HH680400)ADJ. 150-250(HH12ZA011)(HH680405)

• DIFFERENTIAL: 30° F

• SWITCH: SPST

ELEMENT LENGTH (in.) P/N3-3/8 HH12ZA008

3 HH6804007-3/8 HH680405

7 HH680405

P507

• TEMP SETTING: FAN OFF - ADJ. 80° F-120° F

• FAN DIFFERENTIAL: ADJ. 20° F-50° F

ELEMENT LENGTH (in.) P/N7 HH12AB1403 HH12AB141

• KNURLED SHAFTS FORADJUSTMENT OFTEMPERATURE SETTINGAND DIFFERENTIAL

• SLOTTED FOR TWO SCREWMOUNTING

• SWITCH TYPE: SPSTP506

TOTALINE® COMBINATION FAN, LIMIT CONTROLS• MANUAL FAN SWITCH

• INDIVIDUAL FAN AND LIMIT SWITCHES

• HELICAL BI-METAL FOR PRECISE SETTING

• SPST SWITCH

• ADJUSTABLE SETTINGS

• DIFFERENTIAL: LIMIT- 25° F

• TEMPERATURE SETTING:FAN OFF/ON - ADJ. 90° F-135° F (P232-0001,0002)

- ADJ. 90° F-130° F (P232-0003)LIMIT OPENS - ADJ. 100° F-250° F (P232-0001,0002)

- ADJ. 100° F-220° F (P232-0003)

ELEMENTLENGTH (in.)

P/NELEMENT

LENGTH (in.)P/N

8 P232-0001 11.5 P232-00035 P232-0002

P509

P508

• QUICK CONNECTTERMINALS

• 24-VOLT FAN ASSISTHEATER

• TUBE CONSTRUCTIONFOR STRENGTH

• SLOTTED FOR 2SCREW MOUNTING

• SWITCH TYPE: SPST

• ADJUSTABLE FANSETTINGS

• TEMP. SETTING: FAN OFF - ADJ. 80° F - 120° F

• FAN DIFFERENTIAL: 30° F

• ELEMENT LENGTH: 1-1/4"

P/N: HH12HA070

355

FAN, LIMIT CONTROLS

• WITH FAN ASSISTHEATER TO PREVENTNUISANCE FANSTARTING

• INDIVIDUAL SENSINGELEMENTS

• BI-METAL ACTUATED

• SWITCH TYPE: SPST

• TEMP SETTING:FAN OFF -ADJ. 90° F-120° FLIMIT OPENS -SEE CHART BELOW

• DIFFERENTIAL:FAN - 80° F, EXCEPT HH12KA250 WHICH IS 50° FLIMIT - 30° F

• ELEMENT LENGTH:7″ (EXCEPT HH12ZW125 WHICH IS 5″)

*With Shield.**Without Shield.

TEMP. SETTINGLIMIT OPENS (°F)

SETTINGSADJUSTABLE

P/N

250 FAN HH12KA250190 FAN HH12KD020

150-250 ADJ. FAN, LIMIT HH12KD021*150-250 ADJ. FAN, LIMIT HH12KD022**

220 FAN HH12KD023125 FAN HH12KD024170 FAN HH12KD025125 FAN HH12ZW125

P510

• IDEAL FOR PLENUMMOUNTING

• INDIVIDUAL ELEMENTSAND SWITCHES

• ELEMENTS MAY BEREPOSITIONED

• PROVIDED WITH COVER

• SWITCH TYPE: SPST

• TEMP SETTING:FAN ON - 70° F-150° FLIMIT OPENS - 100° F-250° F

• DIFFERENTIAL:FAN - 15° F-55° FLIMIT - 20° F

• SETTINGS ADJUSTABLE: FAN, LIMIT

ELEMENT LENGTH (IN.) P/N9 HH12PZ008

P511

P512

• SLOTTED FOR 2 SCREWMOUNTING

• RIGID TUBECONSTURCTION

• 24 VOLT FAN ASSISTHEATER

• QUICK CONNECTELECTRICAL TERMINALS

• SWITCH TYPE: SPST• *TEMP SETTING: FAN

OFF - ADJ. 80° F-120° FLIMIT OPENS - SEECHART BELOW

• DIFFERENTIAL: FAN- 35° F; LIMIT - 40° F

TEMP. SETTINGLIMIT OPENS (°F)

SETTINGSADJUSTABLE

P/N

259 5-3/4 HH680505

COMBINATION FAN, LIMIT CONTROLS• INDIVIDUAL FAN AND LIMIT SWITCHES

• HELICAL BI-METAL FOR PRECISE SETTING

• SPST SWITCH

• ADJUSTABLE SETTINGS

• DIFFERENTIAL: LIMIT -25°

• TEMPERATURE SETTING:FAN OFF/ON -ADJ. 90° F-135° F (HH12AT005,008)

-ADJ. 90° F-130° F (HH12AT015)LIMIT OPENS -ADJ. 100° F-250° F (HH12AT005,008)

-ADJ. 100° F-220° F (HH12AT015)

• TEMPERATURE SETTING:FAN ON - 20 TO 90 SECONDS AFTER FAN ASSIST

HEATER ENERGIZED (HH12AT016)FAN OFF - ADJ. 100° FLIMIT OPENS - ADJ. 150° F-250° F

ELEMENTLENGTH (in.)

P/NELEMENT

LENGTH (in.)P/N

5 HH12AT005 11.5 HH12AT0158 HH12AT008 8 HH12AT016

P509

356

FAN, LIMIT CONTROLSCOMBINATION FAN, LIMIT CONTROLS (cont)

SWITCH - COMBINATION FAN AND LIMIT

P/N P232-L4064BFan and Limit Control

• FAST RESPONSE BIMETALELEMENT WITH LARGERSURFACE AREA ALLOWS FASTERROTATION DURINGTEMPERATURE CHANGERESPONSE.

• FASTER TEMPERATURE CHANGERECOGNITION FOR SAFEROPERATION.

• WIDER OPENING STEELSURROUNDING BIMETALELEMENT ALLOWS HOT GASPENETRATION FOR FASTERTEMPERATURE SENSING ANDIMPROVED TEMPERATURETRACKING.

TOTALINEPART NUMBER

HONEYWELLPART NUMBER

DESCRIPTION

P232-L4064B-11 L4064B2210 Fan & Limit 11-1/2″P232-L4064B-8 L4064B2228 Fan & Limit, 8″P232-L4064B-5 L4064B2236 Fan & Limit, 5″

P509

ELEMENTLENGTH

(in.)

SWITCHCLOSESADJ. FAN

RANGE (°F)

SWITCH OPENSADJ. FAN

RANGE (°F)

SWITCHCLOSESADJ. FAN

RANGE (°F)

SWITCH OPENSADJ. FAN

RANGE (°F)P/N

6 90-120 75 FIXED 230 FIXED 30 FIXED HH6805017 90-120 35 FIXED 200 FIXED 30 FIXED HH6805027 90-120 75 FIXED 240 FIXED 30 FIXED HH6805047 90-120 50 FIXED 150-250 30 FIXED HH680506

P510

357

FAN, LIMIT CONTROLSFAN SWITCH - INSERTION TYPE

FAN LIMIT SWITCH - INSERTION TYPE

• KNURLED SHAFTS FOR ADJUSTMENT OF TEMPERATURE SETTING ANDDIFFERENTIAL

• SLOTTED FOR TWO SCREW MOUNTING.

ELEMENTLENGTH

(in.)

SWITCH CLOSESADJUSTABLE FAN

RANGE (°F)

SWITCH OPENSADJUSTABLE FAN

RANGE (°F)

SWITCHTYPE

P/N

3 80-120 25 FIXED SPST L4068E10473 70-140 25-45 SPST HH6802013 80-120 65 FIXED SPST HH6802037 70-140 25-45 SPST HH6802047 80-110 65 FIXED SPDT HH680205

P506

ELEMENTLENGTH

(in.)

SWITCH CLOSESADJUSTABLE FAN

RANGE (°F)

SWITCH OPENSADJUSTABLE FAN

RANGE (°F)

SWITCHTYPE

P/N

7 180 FIXED 10 FIXED SPDT HH6804017 190 FIXED 30 FIXED SPDT HH6804027 200 FIXED 30 FIXED SPDT HH6804037 210 FIXED 30 FIXED SPDT HH6804047 165 FIXED 30 FIXED SPDT HH11KT1657 180 FIXED 40 FIXED SPST HH12ZB1783 160 FIXED 30 FIXED SPST HH12ZA1627 170 FIXED 40 FIXED SPST HH12ZA169

P505

358

IGNITION SYSTEMSPILOT BURNERS

PILOT STYLE GAS ORIFICE SIZE P/N2H w/COIL NAT. .021 LH680006

2H w/o COIL NAT. .021 LH680004

The 2H or 2CH Pilot hasSPDT switch action for usewith 11 volt glow coil systems.

P513

The 734 model pilot burner is foruse with a 30 MV thermocouplein standing pilot applications.Snap in or threaded thermocou-ples may be used.

GASORIFICE

SIZEP/N

NAT. .017 LH31JZ022

P514

Model E28 pilot burner is forassembly with LH33WZ506 elec-trode and HH71PD001 sensor.Spark igniter LH33WZ059 andpilot orifice LH39WD020 must beordered separately.

• NATURAL GAS

PILOTSTYLE

ORIFICESIZE

P/N

E28 .020 LH31WZ507P515

The following “J” style pilotburners are for use withLH33CM600 spark igniter.

Burners come with sparkelectrode and high tensionlead and insulating bootattached. SensorLH33CM018 and spark gen-erator LH33CZ007 required.

*Angle of hood as viewed from electrode LH-Left Hand,ST-Straight.

** Includes LH31CM021 Nat. gas burner and LH32RN009 orifice forL.P. conversion.

HOODPOSITION*

LEADLENGTH (in.)

ORIFICESIZE

P/N

LH 17.0 .023 LH31CM017ST 18.0 .018 LH31CM023STLH

12.517.0

.023, .009.023

LH660003**LH660004

ST 20.0 .023 LH31CM300

P516

LH33JZ053 is a differentialexpansion pilot equipped witha 2 lead SPST switch for usewith glow coil or spark ignition.

Differential expansion pilotequipped with a 3 lead SPDTswitch for use with glow coil orspark ignition.

Molex connector included.

PILOTSTYLE

ORIFICESIZE

P/N

732C .017 LH33JZ053

PILOTSTYLE

ORIFICESIZE

P/N

740A .017 LH680005

P518

P517

This LH31RB015 model pilotburner is used in standing pilotapplications. 2 pilot orifices areprovided. One for natural gas isinstalled in the burner. Theextra one is for use with L.P.gas.

GASORIFICE

SIZEP/N

NAT. .016LH31RB015

L.P. .010MODEL NO. 2CH

P519

The Q345 pilot burner includespilot orifice, spark electrodeand flame ground. This burneris for use with Honeywell S86spark module.

Converts to LP gas withLH32RM015 pilot orifice.

GASORIFICE

SIZEP/N

NAT. .018 LH680001MODEL NO. Q345

Q314A pilot burneris a nonaerated typewith .018 orifice foruse with natural gas

P/N LH660001

P524P524B

P520

P313A

359

IGNITION SYSTEMSPILOT BURNERS

IGNITERS

The E25 and E27 model pilotburners are for use withLH31WM001 Igniter andHH71PD001 Sensor.LH33WM001 Igniter must beused with HT01AW024 IgnitionTransformer.

Pilot orifice LH39WD020 notfurnished.

• NATURAL GAS

• ORIFICE SIZE: .020

MODEL NUMBER P/NE25 (LH) LH31WF038E27 (RH) LH31WF039

Q314A pilot burner is a non-aerated type with .018 orifice foruse with natural gas.

P/N: LH31AC013

P/N: LH31AC015

P521

P524

P524B

P524A

This solid state igniter featurespush on high tension lead con-nector. Igniter provides continu-ous spark until pilot flame isestablished. 24 volt system.Replaces: LH33EP030,LH33WZ502.

IGNITER MODEL: 990

VOLTS FUNCTION P/N24 NON-100% LOCKOUT LH33WZ51024 5 MIN. 100% LOCKOUT LH33WZ512

245 MIN. 100% LOCKOUT w/20SEC. PILOT GAS PREPURGE

LH33WZ513

This igniter provides intermit-tent pilot burner ignition. S86Eprovides continuous trial forignition. S86G and S86H pro-vides safe lockout if pilot doesnot ignite in 90 second trial forignition period.

System volts - 25.

IGNITERMODEL

COMPATIBLEH-W VALVE

P/N

S86E 844,8440 LH660010S86H ALL I.I.D. VALVES LH660011S86F ALL I.I.D. VALVES LH680510

Use these igniters with the “J” style pilot burners. Igniters aresuitable for panel mounting. The LH33CM600 may be mounteddirectly on Penn valves EF33CZ206 and 209. The LH33CZ003can be mounted on Penn valve EF33CZ210 by removing mount-ing bracket.The LH33CM018 sensor and RM01680001 sensor cable arerequired. 24 volt system.

IGNITER MODEL:G60

P/N: LH33CM600 IGNITER MODEL:G67

P/N: LH33CZ003

P523

P526

P525

P522

P4316

• Provides ignition sequence, flamerectification and safety shutoff forintermittent pilot central furnacesand heating appliances.

• For use with single rod or dualrod/remote sense applications.

• For use with natural or LP gas.• Replaces over 300 existing IP

modules including Honeywell,Robertshaw, Penn Johnson,Fenwal and others.

P/N: P691-S8610U

Universal Intermittent Pilot Module

360

IGNITION SYSTEMSIGNITERS

Solid state igniter creates theignition voltage required to ignitepilot gas. Provides automaticrelight if pilot flame is extin-guished while thermostat is call-ing for heat.

Igniter model 5059.

NOTE: For use with LH31WZ507 pilot burner and LH33WZ506electrode. HH71PD001 used as flame sensor and pilot switch.

PRIMARYVOLTS

POWER CONNECTIONSP/N

PRIMARY SECONDARY25 1/4″ Q.C. 1/4″ Q.C. 5059-023

120 6″ LEADSSPARK PLUGOR 1/4″ Q.C.

LH33WZ059

P527

The SX611 Ignition Module gen-erates a high-voltage spark andprovides a continuous trial forpilot ignition. The SX611 will alsoautomatically try to re-establishthe pilot flame should it be extin-guished while the thermostat iscalling for heat.

IGNITERMODEL P/NSX611 LH33EP040P1210

Solid state igniter for use with glowcoils used on 732 and 740 pilotburner. Igniter cycles glow coil andregulates coil voltage to increasecoil life. System volts - 24.

IGNITERMODEL

P/N

870 LH33JZ050P531

• Use with “J” style pilot.• Panel mount.• 24 volt.• 100% lockout, 120 sec. nominal trial

for ignition, with 4 second pilot gasprepurge.

MODEL: G770

P/N: LH33CZ007P532

HOT SURFACE IGNITER

Designed for use with LH680-012or013 flame sensor.

NORTON MODEL: 271

P/N: LH33ZS004

P534

P4317

Universal Hot Surface Ignition Module• Provides easy

field-replacement of a widerange of hot surface ignitionmodules by Honeywell,Robertshaw and WhiteRodgers.

• Single rod or remote dual rodrectification type flame sensing.

• LED signals system lockout,weak flame signal or internalerror.

• Selectable number of ignitiontrials (1 or 3).

• Selectable length of trial forignition (4 or 7 seconds).

P/N: P691-S910U

P1209

361

IGNITION SYSTEMS

ELECTRODES GLOW COILSThis electrode is designed formounting on pilot burnerLH31WZ507. Spark igniterLH33WZ505 and flame sen-sor HH71PD001 are requiredfor complete ignition system.

MODEL NO.: 760

P/N: LH33WZ506

Designed specifically for usewith LH68005 and LH33JZ053pilot burners. Locating tabsand locking screw provideaccurate location for requiredspark gap. Spike connectionreplaces quick connect style.

MODEL NO.: AM11

P/N: LH680512P536

P535

This is the replacement igni-tion coil for the 2H pilot burnersupplied in the LH68006 pilepackage. Use with48DA660025 resistance wirepackage.

PILOT STYLE: 2H

NOM. VOLTS: 10

P/N: LH39JZ051P538

This igniter coil assembly isused with pilot burnersLH68005 and LH33JZ053glow coil voltage source mustbe limited to maximum of11 volts.

PILOT STYLE: 740

NOM. VOLTS: 10

P/N: LH39JZ020

P539

This igniter is designed for usewith transformer HT01BD024.Refer to appliance manufac-turer’s instructions for mounting.

PILOT STYLE: J

NOM. VOLTS: 2.5

P/N: HH79CZ036P543

FLAME SENSOR

Sensor is designed for use withLH33ZS004 Hot Surface Igniter.

MODEL NO.: CE6

P/N: 80° FURNACE USE LH68001290° FURNACE USE LH680013

P541

Provided with mounting clip.60” leads with 5/64” thickinsulation.

WHITE-RODGERS

MODEL NO: 760-679

P/N: LH33EW058P540

This sensor is required for usewith the LH33CM600 sparkigniter. It is designed formounting on the Penn “J” stylepilot burners.

MODEL NO.: Y75

P/N: LH33CM018

P537

362

IGNITION SYSTEMSTHERMOCOUPLES

PILOT SAFETY SWITCHES

UNIVERSAL THERMOCOUPLE

P/N P671-Q340A Universal Thermocouple

• REPLACES ALMOST ANY 30 mV THERMOCOUPLE.• AVERAGE OPERATING LIFE OF TEN YEARS.• BOTTOM LOCK DESIGN ALLOWS FOR ONE HAND

INSTALLATION.• UNIVERSAL ADAPTER MAKES THIS THE

TWO-TO-ONE INSTALLER-PREFERREDTHERMOCOUPLE IN INDEPENDENT HVAC SURVEY.

PART NUMBERHONEYWELL

PART NUMBERDESCRIPTION

P671-Q340A-18 A340A1066 Thermocouple 18″P671-Q340A-24 Q340A1074 Thermocouple 24″P671-Q340A-30 Q340A1082 Thermocouple 30″P671-Q340A-36 Q340A1090 Thermocouple 36″P671-Q340A-48 Q340A1108 Thermocouple 48″

TOTALINE THERMOCOUPLE KIT

P466

* FOR 30 MILLIVOLT CONTROLS* ADAPTERS TO FIT MOST PILOT

BURNERS* INSTALLATION INSTRUCTIONS ON

PACKAGEWith only three adapter fittings this thermocouplewill service most pilot burners old or new, while theselection of lengths assures you of competitivepricing.

Most pilot burner applications can be serviced withthis thermocouple replacement kit. Thermocouplehas nominal 30 millivolt rating and comes withinstructions.

LENGTH (in.) P/N24 P671-424230 P671-430236 P671-436248 P671-4482

This auto reset, SPDT pilotswitch is used with a nominal30MV thermocouple.

Electrical connections areenclosed. Mount upright in boxor on panel. Lighting pilot auto-matically closes switch.

MODEL NO.: L61LL

P/N: HH71CC150

• SOLID STATE LOCKOUTTIMER

• 30 SECOND TRIAL FORIGNITION

• MAY BE RESET AFTER 30SEC.

• 24 VOLT INPUT

MODEL NO.: 990l141

P/N: HH72CH003

This 100% shut-off pilot switchis for use with a nominal 30MVthermocouple. On pilot flamefailure, pilot gas and power tomain valve are shut off untilpilot is manually re-established.

MODEL NO.: L62CC

TUBE SIZE: 1/4″ O.D.

P/N: HH71MB066

TERM.CONN. (in.)

BULBMOUNTING

STYLE

CAPIL.LENGTH (in.)

P/N

1/4 Q.C. LOCKNUT 30 HH71PD0011/45 Q.C. “C” RING 30 HH71PD024

This auto reset, mercury filled,SPDT pilot switch is used withglow coil and spark ignitionsystems.

Check unit manufacturer’s partslist for matching pilot burners.

MODEL NO.: 3049

Manual reset pilot control whichshuts off gas to pilot and mainburners when pilot flame fails.Includes pilot gas filter. Use withnominal 30MV thermocouple.

MODEL NO.: C591A

TUBE SIZE: 1/4″ O.D.

P/N: EF53FB020

P544

P545

P549

P548

P547

363

IGNITION SYSTEMSIGNITION SYSTEM ACCESSORIESRESISTORS

RESISTANCE WIRE

IGNITION LEADS

OHMSRESIST-ANCE

WATTS P/N

4 20 HT21AU0045 20 HT21AU0203 8 5593D5

Resistors and resistance wire are required on some units toreduce the voltage to ignition glow coils. Refer to unit installa-tion and service instructions.

P550

OHMSPERFT.

LENGTH(in.)

P/N

.380 156 48DA660025

This package contains stainless resistance wire used inreducing the 24 volt power source to nominal 9-11 voltsrequired on some glow coil igniters. Instruction sheet included.

P551

HIGH VOLTAGE IGNITION LEAD

Silicone insulated wire for ignitionsystems where high temperature,moisture resistant ignition lead isrequired on outdoor equipment.

ENDCONNECTIONS

WIRELENGTH (in.)

P/N

SPK. PLUG/RING TERM. 20 48MA403742SPARK PLUG 24 B0805050

Q.C./PIN TERM. 24 48DD410452NONE 27 301286-702

QUICK CONNECT 24 RM680002

P552

• PENN SENSOR LEAD

• SILICONE-INSULATEDCOPPER CONDUCTOR

• FOR USE WITHLH33CM600 SPARKMODULE

• QUICK CONNECTS

Q.C.TYPE

Q.C.INSULATED

PENNNO.

LENGTH(in.)

P/N

STRAIGHT YES Y57JH27 27 RM680003ST./FLAG NO Y57HJ24 24 58EGB0805041

P553

LOW PRESSURE SWITCH

COMBUSTION BLOWER ASSEMBLY

RATINGPRESS.

SETTINGP/N

1 AMP 2″ WC HK02LB0051 AMP 6″ WC HK02LB018

These low pressure switches are used in ignition circuits tointerrupt power when gas pressure is low or gas service tounit is shut down. Switch has 1/8″ NPT connection onunderside.

P554

• 100 CFM MAX.

• 230 VOLT

• 1/10 H.P.

• PSC MOTOR

• 3450 RPM

P/N: 48DA660019.22.20.18.14.12.10.8.6.4.20 .16

100

90

80

70

60

50

40

30

20

10

0

P317-1

• 60 CFM MAX.

• 230 VOLT

• 1/80 H.P

• SHADED POLE MOTOR

• 3200 RPM

P/N: LA25UZ001.66.60.54.48.42.36.30.24.18.12.060

64

56

48

40

32

24

16

8

0

P317-2

364

IGNITION SYSTEMSOIL BURNER COMPONENTSOIL PUMPS

OIL BURNER IGNITION TRANSFORMER

COUPLINGS

PUMP STAGES PUMP RPM P/NSUNSTRAND

1 1725 58HH6800272 1725 58HH6800291 3450 58HH6800012 3450 58HH680002

WEBSTER1 1725 58HH6800282 1725 58HH6800301 3450 58HH6800252 3450 58HH680026

SUNSTRAND

• COMPACT SIZE

• 5/16″ DIA. SHAFT

• INTEGRAL BLEEDFITTING FOR EASYSTART UP

WEBSTER

• COMPACT SIZE

• 5/16″ DIA. SHAFT

• INTEGRAL BLEEDFITTING FOR EASYSTART UP

P556P555

• 115 VOLT

• 10,000 VOLT SECONDARY

• 23 MA

BASE (in.) MOUNTINGCENTERS (in.)

P/NWIDTH LENGTH4-7/16 5-7/16 3-1/4 x 4-1/4 HT08BR1154-3/8 5-5/16 3-1/2 x 2-3/4 HT08BR116

P557

ENDS (in.) LENGTH (in.) P/N1/2 x 5/16 4-1/4 58HH680034

P558

PRIMARY CONTROLS• PROVIDES NON-RECYCLING

CONTROL OF ANINTERMITTENT IGNITIONOIL BURNER SYSTEM

• SOLID STATE FLAMESENSING CIRCUIT

• MOUNTS ON STANDARD 4 x4 BOX

• 45 SECOND SAFETYSWITCH TIMING

• MANUAL RESET REQUIREDAFTER SAFETY SHUTDOWN

• USE WITH HH79AY060 CAD CELL• INTEGRAL TRANSFORMER SUPPLIES 24V POWER TO

CONTROL CIRCUITMODEL NO: R8184G

P/N: HH11AZ070

• STACK MOUNTED• MANUAL RESET• FOR USE WITH 2 OR 3 WIRE

CONTROL• MANUAL TRIP SAFETY

SWITCH• INTERRUPTED IGNITIONMODEL NO: RA117A

P/N: HH11AZ040

• INTEGRAL 40VA TRANSFORMER• PROVIDES CONTROL OF AN INTERMITTENT IGNITION

OIL BURNER AND POWER FOR A LOW VOLTAGECOOLING CONTROL CIRCUIT

• EXTRA “Y” AND “G” CONNECTIONS FOR COOLINGMODEL NO: R8184M

P/N: HH11AZ067

• SOLID STATE FLAMESENSING CIRCUIT

• MOUNTS ON STANDARD 4 x 4BOX

• 45 SECOND SAFETY SWITCHTIMING

• USE WITH HH79AY060 CADCELL

• MANUAL RESET REQUIREDAFTER SAFETY SHUTDOWN

P560

P1208

• FAST RESPONSE TIME

• EASY MOUNTING FORACCURATE SIGHTING

• EASY REPLACEMENTOF PLUG IN CELL

• CAD CELLHERMETICALLYSEALED

MODEL NO: C554

P/N: 956-154

P559

P561

365

IGNITION SYSTEMS

OIL BURNER COMPONENTS

• COMPATIBLE WITH HYDRONIC AND FORCED AIRAPPLICATIONS.

• AVAILABLE IN 15 AND 30-SECOND LOCKOUTTIMES.

• SAFE START CHECK.• STATUS INDICATOR LIGHT MONITORS BURNER

FLAME STATUS AND SYSTEM LOCKOUT.• USES PROVEN FLAME DETECTION AND

MONITORING SYSTEMS.• OPTIONAL DELAY ON VALVE, BLOWER OFF

DELAY MODELS.

PRIMARY CONTROLS

P4322

• PRIMARY CONTROL OPERATES THE OIL BURNER,OIL VALVE, AND IGNITION TRANSFORMER IN ARESPONSE FOR A CALL FOR HEAT FROM THETHERMOSTAT.

• LOCKOUT INDICATION LIGHTS REDUCE UNNECES-SARY SERVICE CALLS.

• TAMPER RESISTANT, RUSTPROOF, SCRATCHRESISTANT COVER.

• HIGHEST PERFORMANCE AND RELIABILITY MAKEIT THE PREFERENCE OF ORIGINAL EQUIPMENTMANUFACTURERS.

P/N P691-R818RG Protectorelay/Oil Burner Control

P4324

P/N P691-R7184 Interrupted Electronic Oil Primary

PART NUMBERHONEYWELL

PART NUMBERDESCRIPTION

P691-R7184A-P R7184A1026 Interrupted Electronic Oil PrimaryP691-R7184A-SS R7184A1042 Interrupted Electronic Oil Primary

P691-R7184U R7184U1012 Universal Interrupted Electronic Oil PrimaryP691-R8484G R8184G4009 Protectorelay/Oil Burner Control

SOLID-STATE OIL IGNITER

P/N P691-S7184A Solid State Oil Igniter

• THE SOLID STATE OIL IGNITER IS A LINE VOLTAGE IGNITER FORRESIDENTIAL OIL FIRED BURNERS, FORCED AIR FURNACES, BOILERS,AND WATER HEATERS.

• MOUNTS ON BURNER HOUSING.• DIAGNOSTIC LED INDICATES WHEN THE IGNITER HAS BEEN ENERGIZED.• IGNITER CAN BE USED IN AN INTERMITTENT (CONTINUOUS) OR

INTERRUPTED MODE OF OPERATION.

PARTNUMBER

HONEYWELLPART NUMBER

DESCRIPTION

P691-S7184A S7184A1023 Solid State Oil IgniterP4323