HEAT - Silver Linings Systems · Silver Linings Systems’ Heat Exchangers use chilled water to...

2
Handle the Heat Mount anywhere Keep operating costs low Defend against overheating Ice out hot spots Silver Linings Systems’ Heat Exchangers use chilled water to create air cooling, providing a comfortable temperature for both employees and IT equipment. Versatile and efficient, heat exchangers are a perfect choice for a wide range of environments. Our variety of mounting kits let you install anywhere there’s plumbing. Minimize energy costs with fans that run only when needed. Extend the life of expensive hardware with versatile, go-anywhere cooling. Targeted cooling takes the pressure off your building’s A/C system. HEAT EXCHANGERS SilverLiningsSystems.com

Transcript of HEAT - Silver Linings Systems · Silver Linings Systems’ Heat Exchangers use chilled water to...

Page 1: HEAT - Silver Linings Systems · Silver Linings Systems’ Heat Exchangers use chilled water to create air cooling, providing a comfortable temperature for both employees and IT equipment.

Handle the Heat

Mount anywhere

Keep operating costs low

Defend against overheating

Ice out hot spots

Silver Linings Systems’ Heat Exchangers use chilled water to create air cooling, providing a comfortable temperature for both employees and IT equipment. Versatile and efficient, heat exchangers are a perfect choice for a wide range of environments.

Our variety of mounting kits let you install anywhere there’s plumbing.

Minimize energy costs with fans that run only when needed.

Extend the life of expensive hardware with versatile, go-anywhere cooling.

Targeted cooling takes the pressure off your building’s A/C system.

HEAT EXCHANGERS

SilverLiningsSystems.com

Page 2: HEAT - Silver Linings Systems · Silver Linings Systems’ Heat Exchangers use chilled water to create air cooling, providing a comfortable temperature for both employees and IT equipment.

Tackle any high-heat environment with intelligently efficient cooling.

Mounting Options

• Horizontal for mounting from ceiling• Base for stand-alone placement• Vertical for column mounting• Duct extension for cooling an adjacent room• Connect to existing facility plumbing

*Specs for 12-fan configuration

Get the right protection for your business.Contact us at 262-612-1355 or [email protected]

9625 55th St., Kenosha, WI 53144

Industrial Use

Component Overview

Not seeing what you need? A Silver Linings expert can create a custom solution for you.

Your Heat Exchanger may need a Fluid Cooler and Chiller to maximize cooling power.

Server Rooms Offices

Cool individual rooms or trouble spots in your work space

Maintain a constant temperature even in high-density rooms

Manage hot spots in expansive facilities with minimal noise

Cooling Capacity 39,000 BTU/hr (3.25 RT)

Input Power 120 V (5.4 amps)

Fans (12) 6” variable speed AC panel fans

Operating Conditions 40°-104°F (indoor use only)

Sound Performance ≤ 70dBa at 1m

120-Volt Power

Fluid connections

Coil

Thermister

Variable Speed Fans

Condensate pump(interior)