Heat & Glo Gateway 288-900 Rev. S 3/06 1 Model: GATEWAY Installers Guide Underwriters Laboratories Listed - Do not store or use gasoline or other flammable vapors and liquids in the vi- cinity of this or any other appliance. - What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your build- ing. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. WARNING: IMPROPER INSTALLA- TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM- AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR- MATION CONSULT A QUALIFIED IN- STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE. 1. This appliance may be installed in an af- termarket, permanently located, manufac- tured (mobile) home, where not prohibited by local codes. 2. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973. Printed in U.S.A. Copyright 2006 Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS- ING PROPERTY DAMAGE, PER- SONAL INJURY, OR DEATH. This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. In the Commonwealth of Massachusetts: installation must be performed by a licensed plumber or gas fitter; See Table of Contents for location of additional Commonwealth of Massachusetts requirements.

Transcript of heat n glow gateway fireplace

Page 1: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 1

Model:GATEWAY

Installers Guide

UnderwritersLaboratories Listed

- Do not store or use gasoline or otherflammable vapors and liquids in the vi-cinity of this or any other appliance.

- What to do if you smell gas• Do not try to light any appliance.• Do not touch any electrical switch.• Do not use any phone in your build-

ing.• Immediately call your gas supplier from

a neighbor's phone. Follow the gassupplier's instructions.

• If you cannot reach your gas supplier,call the fire department.

- Installation and service must beperformed by a qualified installer, serviceagency, or the gas supplier.

WARNING: IMPROPER INSTALLA-TION, ADJUSTMENT, ALTERATION,SERVICE OR MAINTENANCE CANCAUSE INJURY OR PROPERTY DAM-AGE. REFER TO THIS MANUAL. FORASSISTANCE OR ADDITIONAL INFOR-MATION CONSULT A QUALIFIED IN-STALLER, SERVICE AGENCY, OR THEGAS SUPPLIER.

READ THIS MANUAL BEFORE INSTALLING OROPERATING THIS APPLIANCE. THIS INSTALLERSGUIDE MUST BE LEFT WITH APPLIANCE FORFUTURE REFERENCE.

1. This appliance may be installed in an af-termarket, permanently located, manufac-tured (mobile) home, where not prohibitedby local codes.

2. This appliance is only for use with the typeof gas indicated on the rating plate. Thisappliance is not convertible for use withother gases, unless a certified kit is used.

Please contact your Heat & Glo dealer with anyquestions or concerns. For the number of your nearestHeat & Glo dealer, please call 1-888-427-3973.

Printed in U.S.A. Copyright 2006

Heat & Glo, a brand of Hearth & Home Technologies Inc.20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATIONIN THESE INSTRUCTIONS IS NOTFOLLOWED EXACTLY, A FIRE OREXPLOSION MAY RESULT CAUS-ING PROPERTY DAMAGE, PER-SONAL INJURY, OR DEATH.

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,780403, 1418504 or other U.S. and foreign patents pending.

In the Commonwealth of Massachusetts:• installation must be performed by a licensed

plumber or gas fitter;See Table of Contents for location of additionalCommonwealth of Massachusetts requirements.

Page 2: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/062

These units MUST use one of the vent systemsdescribed in the Installing the Fireplace section ofthe Installers Guide. NO OTHER vent systems orcomponents MAY BE USED.

This gas fireplace and vent assembly MUST bevented directly to the outside and MUST NEVER beattached to a chimney serving a separate solid fuelburning appliance. Each gas appliance MUST USEa separate vent system. Common vent systems arePROHIBITED.

INSPECT the external vent cap on a regular basis tomake sure that no debris is interfering with the airflow.

The glass door assembly MUST be in place andsealed, and the trim door assembly MUST be inplace on the fireplace before the unit can be placedinto safe operation.

DO NOT OPERATE this appliance with the glassdoor removed, cracked, or broken. Replacement ofthe glass door should be performed by a licensedor qualified service person. DO NOT strike or slamthe glass door.

The glass door assembly SHALL ONLY bereplaced as a complete unit, as supplied by the gasfireplace manufacturer. NO SUBSTITUTE materialmay be used.

DO NOT USE abrasive cleaners on the glass doorassembly. DO NOT ATTEMPT to clean the glassdoor when it is hot.

Turn off the gas before servicing this appliance. It isrecommended that a qualified service technicianperform an appliance check-up at the beginning ofeach heating season.

Any safety screen or guard removed for servicingmust be replaced before operating this appliance.

READ and UNDERSTAND all instructions carefullybefore starting the installation. FAILURE TOFOLLOW these installation instructions may resultin a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, READ theUsing Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has beenunder water. Immediately CALL a qualified servicetechnician to inspect the unit and to replace any partof the control system and any gas control which hasbeen under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be PERFORMED by aqualified service person. The appliance and ventingsystem should be INSPECTED before initial useand at least annually by a professional serviceperson. More frequent cleaning may be requireddue to excessive lint from carpeting, beddingmaterial, etc. It is IMPERATIVE that the unit’scontrol compartment, burners, and circulating airpassageways BE KEPT CLEAN to provide foradequate combustion and ventilation air.

Always KEEP the appliance clear and free fromcombustible materials, gasoline, and otherflammable vapors and liquids.

NEVER OBSTRUCT the flow of combustion andventilation air. Keep the front of the applianceCLEAR of all obstacles and materials for servicingand proper operations.

Due to the high temperature, the appliance shouldbe LOCATED out of traffic areas and away fromfurniture and draperies. Clothing or flammablematerial SHOULD NOT BE PLACED on or near theappliance.

Children and adults should be ALERTED to thehazards of high surface temperature and shouldSTAY AWAY to avoid burns or clothing ignition.Young children should be CAREFULLY SUPERVISEDwhen they are in the same room as the appliance.

!

!

!

!

!!

!

! !

!

!

!

!

!

!

!

!

SAFETY AND WARNING INFORMATION

!

DO NOT place furniture or any other combustiblehousehold objects within 36 inches of the fireplacefront.

!

Page 3: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 3

Safety and Warning Information. ..........................................2

Service Parts Lists. ...............................................................4

Section 1: Approvals and Codes. .........................................7Appliance Certification..............................................................7Installation Codes .....................................................................7High Altitude Installations ..........................................................7Requirements for the Commonwealth of Massachusetts .......8

Section 2: Getting Started. ...................................................9Introducing the Heat & Glo Gas Fireplaces ..............................9Pre-installation Preparation ......................................................9

Section 3: Installing the Fireplace. .................................... 11Constructing the Fireplace Chase ......................................... 11Step 1 Locating the Fireplace ............................................. 11Step 2 Framing the Fireplace .............................................12Step 3 Negative Pressure ...................................................13Step 4 Installing the Vent System .......................................14

A. Vent System Approvals .......................................14B. System Components ..........................................14C. Vent Termination .................................................20

Step 5 Positioning, Leveling, andSecuring the Fireplace ............................................22

Step 6 The Gas Control System.........................................23Step 7 The Gas Supply Line ...............................................23Step 8 Gas Pressure Requirements ..................................23Step 9 Wiring the Fireplace ................................................24Step 10 Finishing ..................................................................25Step 11 Installing Trim, Logs, and Ember Material ...............26

Installing the Trim ....................................................26Shutter Settings .......................................................26Positioning the Logs ................................................26Placing the Ember Material .....................................26Lava Rock ...............................................................27

Step 12 Before Lighting the Fireplace ...................................27Step 13 Lighting the Fireplace ..............................................27After the Installation ................................................................27

Section 4: Maintaining and Servicing Your Fireplace. ....28

Table of Contents

= Contains updated information.

Page 4: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/064

Part number list on following page.

6 Log Set Assembly

16

1

2 4

3

5

11

91013

7 128

14

15

(NG, LP) Exploded Parts Diagram

Service Parts GATEWAYBeginning Manufacturing Date: 1-02Ending Manufacturing Date: ______

17

18

19

Page 5: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 5

Service Parts List

ITEM DESCRIPTION SERIAL # PART NUMBER

1 Burner NG 288-176A

1 Burner LP 288-175A

2 Glass Door Assembly GLA-GATEWAY

3 Louver Assembly, Top 288-252A

4 Louver Assembly, Bottom 288-249A

5 Hood 288-174

6 Log Set Assembly LOGS-GATEWAY

7 Log 1 SRV288-721

8 Log 2 SRV675-722

9 Log 3 SRV288-726

10 Log 4 SRV288-723

11 Log 5 SRV285-720

12 Log 6 SRV278-705

13 Log 7 SRV285-725

14 Side Refractory 288-280

15 Log Grate 288-360A

16 Draft Assist Blower 288-500

17 Surround 288-130

18 Non-combustible Board 288-401

19 Trim Door Mesh MESH-550-C

4" Exhaust Collar Assembly 288-210A

Touch Up Paint TUP-GBK-12

Glass Latch Assembly 386-122A

Outside Air Handle 288-103

Lava Rock Bag 705-420

Mineral Wool 050-721

ACCESSORIES

Fan Kit GFK-160A

Remote Control Kit RC-SMART-HNG

Remote Control Kit SMART-STAT-HNG

Conversion Kit NG NGK-GATEWAY

Conversion Kit LP LPK-GATEWAY

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,supply serial and model numbers to ensure correct service parts.

GATEWAY

Page 6: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/066

(NG, LP) Exploded Parts Diagram

Service Parts GATEWAYBeginning Manufacturing Date: 1-02Ending Manufacturing Date: ______

ITEM DESCRIPTION SERIAL # PART NUMBER1 ON/OFF Rocker Switch 060-521A2 Valve NG 593-5002 Valve LP 593-5013 Flexible Gas Connector 477-301A4 Module 593-5925 Wire Assembly 288-593a6 Pilot Assembly NG 385-510a6 Pilot Assembly LP 385-511a7 Pilot Brackete 288-1638 Valve Bracket 288-1459 Flex Ball Valve Assembly 302-320A10 Vacuum Switch 288-52111 Junction Box 288-250A12 3V Adaptor Plug 593-593a13 Burner Orifice (#32A) NG 420-80013 Burner Orifice (#50A) LP 446-80114 Vacuum Hose (Teflon Tube) 421-9

Ground Strap 385-512Pilot Spud (NG) 446-505Pilot Spud (LP) 446-517Regulator (NG) NGK-DXFRegulator (LP) LPK-DXF

Intermittent Pilot IgnitionValve Assembly

2

9

10

4

1

5

3

6

13 7

12

11

8

14

Page 7: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 7

Appliance CertificationThe Heat & Glo fireplace model discussed in this InstallersGuide has been tested to certification standards and listedby the applicable laboratories.

CertificationMODEL: GATEWAYLABORATORY: Underwriters LaboratoriesTYPE: Vented Gas FireplaceSTANDARD: ANSI Z21.50•CSA2.22

Installation CodesThe fireplace installation must conform to local codes. Beforeinstalling the fireplace, consult the local building codeagency to ensure that you are in compliance with allapplicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation mustconform to the National Fuel Gas Code ANSI Z223.1 (inthe United States) or the CAN/CGA-B149 Installation Codes(in Canada). The appliance must be electrically groundedin accordance with local codes or, in the absence of localcodes with the National Electric Code ANSI/NFPA No. 70(in the United States), or to the CSA C22.1 Canadian ElectricCode (in Canada).

These models (natural gas and propane) can be installed ina bedroom (in the United States) which has a total volumeof unconfined space appropriate to the particular installation.Refer to the National Fuel Gas Code ANSI Z223.1/NFPA54(current edition). The Uniform Mechanical Code - (current

1Approvals and Codes

edition), and local Building Officials for the options allowedin obtaining an effective bedroom volume of unconfinedspace.

These models (natural gas and propane) can be installed ina bedroom (in Canada) if a thermostat (Model WH-STAT) isinstalled with the unit. Consult local code authorities.Detailed installation instructions for Model WH-STAT areincluded with the kit.

High Altitude InstallationsU.L. Listed gas appliances are tested and approved with-out requiring changes for elevations from 0 to 2,000 feet inthe U. S. A. and in Canada.

When installing this appliance at an elevation above 2,000feet, it may be necessary to decrease the input rating bychanging the existing burner orifice to a smaller size. Inputrate should be reduced by 4% for each 1000 feet above a2000 foot elevation in the U.S.A. or 10% for elevationsbetween 2000 and 4500 feet in Canada. If the heating valueof the gas has been reduced, these rules do not apply. Toidentify the proper orifice size, check with the local gasutility.

If installing this appliance at an elevation above 4,500 feet(in Canada), check with local authorities.

Heat & Glo Quality Systemsregistered by SGS ICS

Page 8: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/068

For all side wall horizontally vented gas fueled equipmentinstalled in every dwelling, building or structure used inwhole or in part for residential purposes, including thoseowned or operated by the Commonwealth and where theside wall exhaust vent termination is less than seven (7)feet above finished grade in the area of the venting, includ-ing but not limited to decks and porches, the following re-quirements shall be satisfied:

Installation of Carbon Monoxide DetectorsAt the time of installation of the side wall horizontal ventedgas fueled equipment, the installing plumber or gasfittershall observe that a hard wired carbon monoxide detectorwith an alarm and battery back-up is installed on the floorlevel where the gas equipment is to be installed. In addi-tion, the installing plumber or gasfitter shall observe that abattery operated or hard wired carbon monoxide detectorwith an alarm is installed on each additional level of thedwelling, building or structure served by the side wall hori-zontal vented gas fueled equipment. It shall be the respon-sibility of the property owner to secure the services of qual-ified licensed professionals for the installation of hard wiredcarbon monoxide detectors.

In the event that the side wall horizontally vented gas fu-eled equipment is installed in a crawl space or an attic, thehard wired carbon monoxide detector with alarm and bat-tery back-up may be installed on the next adjacent floorlevel.In the event that the requirements of this subdivision cannot be met at the time of completion of installation, theowner shall have a period of thirty (30) days to comply withthe above requirements; provided, however, that during saidthirty (30) day period, a battery operated carbon monoxidedetector with an alarm shall be installed.

Approved Carbon Monoxide DetectorsEach carbon monoxide detector as required in accordancewith the above provisions shall comply with NFPA 720 andbe ANSI/UL 2034 listed and IAS certified.

SignageA metal or plastic identification plate shall be permanentlymounted to the exterior of the building at a minimum heightof eight (8) feet above grade directly in line with the ex-haust vent terminal for the horizontally vented gas fueledheating appliance or equipment. The sign shall read, inprint size no less than one-half (1/2) inch in size, “GASVENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-STRUCTIONS”.

InspectionThe state or local gas inspector of the side wall horizontallyvented gas fueled equipment shall not approve the installa-tion unless, upon inspection, the inspector observes carbonmonoxide detectors and signage installed in accordance withthe provisions of 248 CMR 5.08(2)(a)1 through 4.

ExemptionsThe following equipment is exempt from 248 CMR 5.08(2)(a)1through 4:

• The equipment listed in Chapter 10 entitled “EquipmentNot Required To Be Vented” in the most current editionof NFPA 54 as adopted by the Board; and

• Product Approved side wall horizontally vented gas fu-eled equipment installed in a room or structure sepa-rate from the dwelling, building or structure used in wholeor in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall hor-izontally vented gas equipment provides a venting systemdesign or venting system components with the equipment,the instructions provided by the manufacturer for installa-tion of the equipment and the venting system shall include:

• Detailed instructions for the installation of the ventingsystem design or the venting system components; and

• A complete parts list for the venting system design orventing system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wallhorizontally vented gas fueled equipment does not providethe parts for venting the flue gases, but identifies “specialventing systems”, the following requirements shall be sat-isfied by the manufacturer:

• The referenced “special venting system” instructions shallbe included with the appliance or equipment installationinstructions; and

• The “special venting systems” shall be Product Approvedby the Board, and the instructions for that system shallinclude a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap-proved side wall horizontally vented gas fueled equipment,all venting instructions, all parts lists for venting instruc-tions, and/or all venting design instructions shall remainwith the appliance or equipment at the completion of theinstallation.

See Gas Connection section for additional Common-wealth of Massachusetts requirements.

NOTE: The following requirements reference variousMassachusetts and national codes not contained inthis document.

Requirements for the Commonwealth ofMassachusetts

Page 9: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 9

2Getting Started

Introducing the Gateway FireplaceThe Gateway fireplace is designed to operate with all ex-haust gases expelled to the outside.

The information contained in this Installers Guide, unlessnoted otherwise, applies to all models and gas controlsystems. Gas fireplace diagrams, including the dimensions,are shown in this section.

Pre-install PreparationThis gas fireplace and its components are tested and safewhen installed in accordance with this Installers Guide.Report to your dealer any parts damaged in shipment,particularly the condition of the glass. Do not install anyunit with damaged, incomplete, or substitute parts.

The vent system components are shipped in separatepackages. The gas logs are shipped in the fireplace andmust be on unwrapped before firing the unit.

Read all of the instructions before starting theinstallation. Follow these instructions carefully duringthe installation to ensure maximum safety and benefit.Failure to follow these instructions will void theowner’s warranty and may present a fire hazard.

When planning a fireplace installation, it’s necessary todetermine:• Where the unit is to be installed.

• The vent system configuration to be used.

• Gas supply piping.

• Electrical wiring.

• Framing and finishing details.

• Whether optional accessories — devices such as a fan,wall switch, fresh air kit or remote control — are desired.

If the fireplace is to be installed on carpeting or tile, or onany combustible material other than wood flooring, thefireplace must be installed on a metal or wood panel thatextends the full width and depth of the fireplace.

WarrantyThe Heat & Glo Warranty will be voided by, and Heat & Glodisclaims any responsibility for, the following actions:

• Installation of any damaged fireplace or vent system com-ponent.

• Modification of the fireplace or vent system.

• Installation other than as instructed by Heat & Glo.

• Improper positioning of the gas logs or the glass door.

• Installation and/or use of any component part not manu-factured and approved by Heat & Glo, not withstandingany independent testing laboratory or other party approvalof such component part or accessory.

ANY SUCH ACTION MAY POSSIBLY CAUSE A FIREHAZARD.

Page 10: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0610

Figure 2.1 Diagram of the GATEWAY

22 5/8(575mm)

39 ¼(997mm)

31 ¼(794mm)3 1/8

(80mm)

37 5/8(955mm)

GAS LINEACCESS

ELECTRICALACCESS

2 1/8(54mm)

2(51mm)

2 5/8(67mm)

5 1/8(131mm)

39 9/16(1005mm)

3 5/8(92mm)

14 1/16(357mm)

38 1/8(968mm)

TOP STANDOFFS

TOP GRILLE

LOWERGRILLE

GAS CONTROLS

RATING PLATE/LABELS

GASACCESS

ELECTRICAL ACCESS

AIR KITKNOCKOUT

Page 11: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 11

3 Installing the Fireplace

Step 1. Locating the FireplaceThe following diagram shows space and clearance require-ments for locating a fireplace within a room.

Minimum Clearances from the Fireplace toCombustible Materials Inches mm

Glass Sides or Ends .......... 3 6 .................914Floor ....................................... 0 .................... 0Metal Sides or Ends ........... 1/2 ........... 12.5mmEdges of Front Face* .......... 0 .................... 0Top ....................................... 3 1/2 ............... 8 9Ceil ing** ............................... 3 6 .................914

Figure 3.1 Fireplace Dimensions, Locations, and Space Requirements

Minimum Clearances from the Vent Pipe toCombustible Materials

B-Vent PV-FlexInches (mm) Inches (mm)

Vertical Sections. ......... 1 (25) ............. 1 (25)Horizontal SectionsTop ..................................... 1 (25) ..... 1-1/2 (38)Bottom .............................. 1 (25) ............. 1 (25)Sides ................................. 1 (25) ............. 1 (25)At Wall FirestopsTop ..................................... 1 (25) ..... 1-1/2 (38)Bottom .............................. 1 (25) ............. 1 (25)Sides ................................. 1 (25) ............. 1 (25)

* Refer to Diagram of GATEWAY (see Figure 2.1).** The clearance to the ceiling is measured from the top

of the non-combustible board (see Figure 3.29).

For minimum clearances, see the direct vent terminationclearance diagram in this manual (see Figure 3.22).

44” (1118mm)

44” (1118mm)

Constructing the Fireplace Chase

A chase is a vertical box-like structure built to enclose thegas fireplace and/or its vent system. Vertical vents that runon the outside of a building may be, but are not required tobe, installed inside a chase.

CAUTION: TREATMENT OF FIRESTOP SPACERS ANDCONSTRUCTION OF THE CHASE MAY VARY WITH THETYPE OF BUILDING. THESE INSTRUCTIONS ARE NOTSUBSTITUTES FOR THE REQUIREMENTS OF LOCALBUILDING CODES. THEREFORE, YOUR LOCAL BUILD-ING CODES MUST BE CHECKED TO DETERMINE THEREQUIREMENTS FOR THESE STEPS.

Factory-built fireplace chases should be constructed in themanner of all outside walls of the home to prevent cold airdrafting problems. The chase should not break the outsidebuilding envelope in any manner.

This means that the walls, ceiling, base plate and cantileverfloor of the chase should be insulated. Vapor and air infiltra-tion barriers should be installed in the chase as per regionalcodes for the rest of the home. Additionally, in regions wherecold air infiltration may be an issue, the inside surfacesmay be sheetrocked and taped for maximum air tightness.

To further prevent drafts, the firestops should be caulkedwith high temperature caulk to seal gaps. Gas line holesand other openings should be caulked with high temp caulkor stuffed with unfaced insulation. If the appliance is beinginstalled on a cement slab, a layer of plywood may be placedunderneath to prevent conducting cold up into the room.

THE CHASE SHOULD BE CONSTRUCTED SO THAT ALLCLEARANCES TO THE FIREPLACE ARE MAINTAINEDAS SPECIFIED WITHIN THIS INSTALLERS GUIDE.

Clearance RequirementsThe top, back, and sides of the fireplace are defined bystand-offs. The minimum clearance to a perpendicular wallextending past the face of the fireplace is one inch (25mm).The metal ends of the fireplace may NOT be recessed intocombustible construction.

The distance from the unit to combustible constructionis to be measured from the unit outer wrap surface tothe combustible construction, NOT from the screw headsthat secure the unit together.

Page 12: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0612

Figure 3.2 Framing Dimensions

Step 2. Framing the FireplaceFireplace framing can be built before or after the fireplace isset in place. Framing should be positioned to accommo-date wall coverings and fireplace facing material. The dia-gram below shows framing reference dimensions.CAUTION: MEASURE FIREPLACE DIMENSIONS ANDVERIFY FRAMING METHODS AND WALL COVERINGDETAILS BEFORE FRAMING.

NOTE: A 1” clearance (B-Vent) or 1-1/2” clearance(PV-FLEX) must be maintained between the top ofthe pipe in a horizontal configuration and anycombustible materials. Otherwise, 1” clearanceshould be maintained between the pipe and anycombustible materials.

Framing should be constructedof 2 X 4 lumber or heavier.

WARNING: FRAMING DIMENSIONS ASSUMEUSE OF 1/2 INCH THICK WALL COVERING

MATERIALS ON EXTERIOR OF FRAMING ONLYAND NO SHEETROCK ON INTERIOR OF FRAMING.

!

EXHAUSTCOLLAR

1”(25.4mm)

B-Vent1” (25.4mm)

PV-FLEX1-1/2” (38mm)

AB

C

A = 39 3/4 (1010mm)B = 21 5/8 (549mm) 1/2 Sheetrock

21 3/8 (543mm) 5/8 SheetrockC = 40 1/4 (1022mm)

Page 13: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 13

Step 3. Negative Pressure

Recommended Location

MarginalLocation

LocationNot

Recommended

RecommendedLocation

Location NOT Recommended

Multi-level Roofs

Windward

Leeward

Figure 3.3

Draft is the pressure difference needed to vent fireplacessuccessfully. Considerations for successful draft include:• Preventing negative pressure• Location of fireplace and chimney

Negative pressure results from the imbalance of air avail-able for the fireplace to operate properly. Causes for thisimbalance include:

• Exhaust fans (kitchen, bath, etc.)

• Range hoods

• Combustion air requirements for furnaces, water heat-ers and other combustion appliances

• Clothes dryers

• Location of return-air to furnace or air conditioning

• Imbalances of the HVAC air handling system

• Upper level air leaks (recessed lighting, attic hatch open-ing, duct leaks)

To minimize the effects of negative air pressure, the follow-ing must be considered:

• Install the fresh air kit. Install the intake on the side ofthe house towards prevailing winds during the heatingseason.

• Ensure adequate outdoor air is supplied for combustionappliances and exhaust equipment.

• Ensure furnace and air conditioning return vents are notlocated in the immediate vicinity of the fireplace.

• Avoid installing the fireplace near doors, walkways orsmall isolated spaces.

• Recessed lighting should be of “sealed can” design; at-tic hatches weather stripped or sealed; and attic mount-ed ductwork and air handler joints and seams taped orsealed.

• Basement installations should be avoided due to stackeffect. Stack effect creates negative pressure in lowerlevels. Hearth & Home Technologies recommends theuse of direct vent fireplaces in basements.

Location of the fireplace and chimney will affect performance.As shown in Figure 3.3, the chimney should:

• Be installed through the warm space enclosed by thebuilding envelope. This helps to produce more draft, es-pecially during lighting and die-down of the fire.

• Penetrate the highest part of the roof. This minimizesthe effects of wind turbulence.

• Be located away from trees, adjacent structures, un-even roof lines and other obstructions.

Offsets can restrict draft so their use should be minimized.Consider the fireplace location relative to floor and ceilingand attic joists.

Asphyxiation Risk.• Negative pressure can cause spillage of

combustion fumes and soot.• Fireplace needs to draft properly for safety.

WARNING

Page 14: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0614

This unit is equipped to accept outside air. It is recom-mended that an AK-TV air kit be used with this appli-ance. By using outside make-up air, the amount of roomair used for combustion will be reduced. However, in a neg-ative pressure condition the outside air kit MUST be in-stalled to obtain proper performance and to help preventspillage of combustion gases.

A 4-inch side collar/damper (found in AK-TV Kit) must beinstalled on the fireplace by attaching the side collar to theouter wrap of the fireplace at the right-hand rear corner usingsheetmetal screws. Attach damper handle (extended handlefound in manual bag) to the damper door prior to attachingdoor to outer wrap. Then lift the handle into the notch underthe fireplace. See Figure 3.5. Attach one end of a 4-inchflexible air duct (not provided in the AK-TV Kit) to the sidecollar and the other end of the duct to the make-up airtermination cap. Use plastic tie straps to secure the endsof the flex duct to each collar.

Air Damper

Before lighting the burner, open the damper. Close thedamper when the burner is off.

Detailed installation instructions for Model AK-TV OutsideAir kit are found in the kit.

Figure 3.4 Make-up Air

AK-TVAIR

DAMPERASSEMBLY

EXHAUSTCOLLAR

Figure 3.5 Make-up Air Handle

NOTE: Pull handle to open damper. Push handle to closedamper.

HANDLE

NOTCH

!WARNING: WHEN TERMINATING THE VENTINGHORIZONTALLY THE MAKE-UP AIR TERMINATIONMUST BE AT A LOWER ELEVATION THAN THEEXHAUST TERMINATION.

Asphyxiation Risk.Fire Risk.Do NOT draw outside combustion air from:

WARNING

• Wall, floor or ceiling cavity.• Enclosed space such as an attic or garage.• Close proximity to exhaust vents or chimneys.Fumes or odor may result.

Page 15: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 15

!

Step 4. Installing the Vent System

A. Vent System ApprovalsModel GATEWAY is approved to use Duravent 4-inch(102mm) diameter B-type vent for installations that terminatevertically. The PV-Flex Series vent pipe is approved for usein installations that terminate horizontally. This pipe is testedand listed as an approved component of the fireplace.

This model may also use single wall rigid or flexible gasvent IF and ONLY IF the vent system is installed withinnon-combustible construction such as a masonry chimney.The same diameter noted above for B-type vent must beused for single-wall vent (see Figure 3.6).

For B-type vent the clearance to combustibles is 1-inch.Follow vent manufacturers REQUIRED clearances. For PV-Flex the clearances are 1-1/2” top and 1” sides and bottomwhen venting horizontally. For PV-Flex the clearances are1” all sides when passing vertically through combustiblematerials.

High temperature silicone sealant is required at all pipe joints.

NOTE: Due to the positive pressure within the Gatewayventing system, when using PV-FLEX use a 1/2” beadof silicone caulk on ALL pipe ends and connectorsthroughout the vent run to ensure a completely sealedsystem.

Vent pipes must be installed within the conditioned houseenvelope in order to avoid flue gas condensation. Verticaltermination through an unconditioned attic space ispermissible.

The flame and ember appearance may vary based on thetype of fuel burned and the venting configuration used.

B. System ComponentsConsult Local Building Code Officials and Codes for propervent system installations.

Plan and install the vent system using the parameters shownin this vent system configuration chart.

Figure 3.6 Vent System Attachment

! WARNING: THIS GAS FIREPLACE MUST NEV-ER BE VENTED BY CONNECTING TO A CHIM-NEY FLUE SERVING A SEPARATE SOLID FUELBURNING APPLIANCE.

The following figures are examples of approved venting con-ditions. Venting downward (3’ maximum) is approved, toallow venting below the floor. However, only one downwardsection is allowed for up to, but not exceeding 3’ maximum.

NOTE: It is always better to first attach a straight section ofvent to the unit before attaching an elbow. Avoid using el-bows in the vent system if possible.

Continue to add vent components, until the vent run is com-pleted.

Using the four screws provided in the manual bag, attachthe flue outlet collar. Connect a vent component to the flueoutlet collar (see Figure 3.6).

WARNING: YOU MUST NOT EXCEED THESEPARAMETERS.

MAXIMUM TOTAL RUN: = 50 FT.MAXIMUM NO. of ELBOWS/BENDS: five - 90o or ten - 45o

No. of 90O

Elbows/Bends

MaximumVertical Run

MaximumHorizontal Run

MaximumTotal Run

0 - 40' (12.2m) 40' (12.2m)1 50' (15.2m) - 50' (15.2m)

1 - 35' (10.7m) 35' (10.7m)

2 - 35' (10.7m) 35' (10.7m)

2 35' (10.7m) 35' (10.7m) 38' (11.6m)3 30' (9.1m) 35' (10.7m) 35' (10.7m)4 25' (7.6m) 32' (9.8m) 35' (10.7m)5 25' (7.6m) 30' (9.1m) 33' (10.1m)

50 FT.

40 FT.

Page 16: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0616

Figure 3.8 Venting with One 90° Elbow and Vertical Termination

HORIZONTAL VENTING

H (FT.)40' MAX. (12.2m)

2’ MIN. (.6m)

Figure 3.7 Horizontal Venting and Horizontal Termination

V (FT.)50' MAX. (13.8m)

VENTING WITH ONE 90o ELBOW

TERMINATIONCAP

H

TERMINATIONCAP

V

Page 17: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 17

Figure 3.9 Venting with Two 90° Bends and Horizontal Termination

Figure 3.10Venting with Three 90° Elbows and Horizontal Termination

VENTING WITH THREE 90o BENDS

3' MAX. (.91m) 35´ MAX. (10.7m)

V+H+H1+H2 = 35´ MAX.(10.7m)

V (FT.) (DOWN) H + H1+ H2 (FT.)

V (FT.) DOWN3´ MAX. (.91m)

VENTING WITH TWO90o BENDS

H+ H1 (FT.)35´ MAX. (10.7m)

V+H+H1 = 38´ MAX.(11.6m)

V (FT.) UP35´ MAX. (10.7m)

VENTING WITH TWO90o BENDS

H+ H1 (FT.)35´ MAX. (10.7m)

V+H+H1 = 38´ MAX.(11.6m)

Note: Only horizontalventing allowed afterdownward venting run.

Note: Only horizontalventing allowed afterdownward venting run.

H

V

H

1

3’MAXIMUM

H2

H

V

H

1

3 FT.MAXIMUM

H

H1

V

Page 18: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0618

Figure 3.11Venting with Four 90° Bends and Horizontal Termination

VENTING WITH FOUR 90o BENDS

H+H1+H2+H3 (FT.)32' MAX. (9.8m)

Figure 3.12 Venting with Five 90° Bends and Horizontal Termination

VENTING WITH FIVE 90o BENDS

H+H1+H2+H3+H4 (FT.)30' MAX. (9.1m)

V+H+H1+H2+H3+H4 = 33´ MAX.(10.1m)

V+H+H1+H2+H3 = 35´ MAX.(10.7m)

V (FT.) DOWN3' MAX. (.914m)

V (FT.) (DOWN)3' MAX. (.914m)

Note: Only horizontalventing allowed afterdownward venting run.

Note: Only horizontalventing allowed afterdownward venting run.

H

V

H1

3 FT.MAXIMUM

H 3

H 2

H

V

H1

3 FT.MAXIMUM

H 3

H 2

H 4

Page 19: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 19

Figure 3.14 Firestop Wall Hole

Figure 3.15 Interior & Termination Cap Firestops

Install Support Brackets

For Horizontal Runs - The vent system must be sup-ported every five (5) feet of horizontal run by a horizontalpipe support for B-Vent (see Figure 3.21 for PV-Flex pipesupport brackets).

To install support brackets for horizontal runs:

• Place the pipe supports around the vent pipe.

• Nail the pipe supports to the framing members.

To install firestops for horizontal runs that pass througheither interior or exterior walls:• Cut a 7 in. x 8 in. (178mm x 204mm) hole through the wall.

• Position the firestops on both sides of the hole previ-ously cut and secure the firestops with nails or screws.

• Continue the vent run through the firestops.

Install FirestopsFor Horizontal Runs - Firestops are REQUIRED on bothsides of a combustible wall through which the vent passes.

For Vertical Runs - The vent system must be supportedevery eight (8) feet (2.4m) above the fireplace flue outlet bywall brackets.

To install support brackets for vertical runs:

• Attach wall brackets to the vent pipe and secure the wallbracket to the framing members with nails or screws.

8 FT.(2.4mm)

1 INCH MIN.

(25.4mm)

4 INCHELBOW

FLUEOUTLET

4 INCH PIPEB-VENT

WALL STUD

WALL BRACKET

TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT

TERMINATION CAPWITH BUILT-IN

EXTERIOR FIRESTOP

INTERIORFIRESTOP

Figure 3.13 Installing Support Brackets

NOTE: There must be NO INSULATION or othercombustibles inside the framed firestop opening.

7”

8”

Page 20: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0620

If the area above the ceiling is NOT an attic, position andsecure the ceiling firestop on the ceiling side of the previouslycut and framed hole.

Figure 3.16 Hole & New Framing Members

CEILING

NEWFRAMINGMEMBERS

EXISTING CEILING JOISTS

CHIMNEYHOLE

6 1/2" (165mm) 6 1/2" (165mm)

Figure 3.18 Attic Firestop

CEILING

CEILING FIRESTOP

RAFTER

NAILS (4 REQUIRED)

NOTE: For vertical termination the termination cap must belisted for the vent pipe used.

Figure 3.17 Ceiling Firestop (Ceiling Side)

If the area above the ceiling IS an attic, position and securethe firestop on top of the previously framed hole.

JOIST

CEILING FIRESTOP

CEILING

NAILS (4 REQUIRED)

For Vertical Runs - One ceiling firestop is REQUIREDat the hole in each ceiling through which the vent passes.To install firestops for vertical runs that pass through ceilings:• Position a plumb bob directly over the center of the verti-

cal vent component.• Mark the ceiling to establish the centerpoint of the vent.• Drill a hole or drive a nail through this centerpoint.• Check the floor above for any obstructions, such as wir-

ing or plumbing runs.• Reposition the fireplace and vent system, if necessary,

to accommodate the ceiling joists and/or obstructions.• Cut a 6 1/2 in. x 6 1/2 in. (165mm x 165mm) hole through

the ceiling, using the centerpoint previously marked.• Frame the hole with framing lumber the same size as the

ceiling joists.

NOTE: There must be NO INSULATION or othercombustibles inside the framed firestop opening.

Figure 3.18 shows an attic installation. Keep insulation awayfrom the vent pipe at least 1 inch (25mm).While it is not mandatory, it is strongly recommended that anattic insulation shield be used whenever insulation can comein contact with the vent pipe. Follow your local building codes.

Page 21: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 21

!

C. Vent TerminationFor Horizontal Terminations - To attach and securethe termination to the last section of horizontal vent:• Venting from the fireplace must extend through the inte-

rior firestop to flush with exterior surface.• The termination kit should pass through the wall firestops

from the exterior of the building.• Adjust the termination cap to its final exterior position on

the building.• Figure 3.19 shows the approved cap and pipe for hori-

zontal termination. No other components may be used.

! WARNING: THE BOTTOM OF THE VENTTERMINATION CAP MUST BE A MINIMUM

OF 12 INCHES (305 MM) ABOVE GROUND LEVEL(GRADE). THE TOP OF THE CAP MUST BE A MINI-MUM OF 18 INCHES (457 MM) BELOW COMBUSTI-BLE MATERIAL, SUCH AS A DECK, AND THE SIDEOF THE CAP MUST BE A MINIMUM OF 12 INCHES(305 MM) AWAY FROM A PARALLEL OUTSIDE WALL.VENTING TERMINALS SHALL NOT BE RECESSEDINTO A WALL OR SIDING. SEE FIGURE 22 FOR VENTTERMINATION CLEARANCES.

Figure 3.19

PVFLEX-25

PVFLEX-10

25’ Length of Flex Pipe

10’ Length of Flex Pipe

PVFLEXSTARTING COLLAR

BDA-01TRHorizontalTermination Cap

Figure 3.20 PVFLEX-CONNECT

• For vent runs over 25 feet in length, a pipe connectormust be used to connect one pipe section to another(see Figure 3.20).

Install Support BracketsThe PVFLEX pipe run in a horizontal position must be sup-ported at least every 4 feet to assure proper clearances tocombustibles is maintained; 1-1/2" on top and 1" on thesides and bottom. The PVFLEX pipe run in a vertical posi-tion must be supported every 8 feet to maintain clearancesto combustibles 1 inch on all sides .

1/2” bead of Hi temp silicone caulk inside pipe and outside connector

Figure 3.21

FLOORJOISTS

PLUMBERS STRAP

1” MIN.

1” MIN.1” MIN.

FLOOR1-1.2”MIN.

PVFLEX

WARNING: THE TERMINATION CAP MUST BE PO-SITIONED SO THAT THE ARROW IS POINTING UP.

NOTE: Due to the positive pressure within the Gatewayventing system, when using PV-FLEX use a 1/2” beadof silicone caulk on ALL pipe ends and connectorsthroughout the vent run to ensure a completely sealedsystem.

Page 22: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0622

V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED

Figure 3.22 Vent Termination Minimum Clearances

A = 12" ....................... clearances above grade, veran-da, porch, deck or balcony

B = 12" ....................... clearances to window or doorthat may be opened, or to per-manently closed window.

D* = 24" ....................... vertical clearance to unventilat-ed soffit or to ventilated soffit lo-cated above the terminal

*60” ...................... for vinyl clad soffits and belowelectrical service

F = 9" ........................ clearance to outside cornerG = 12" ....................... clearance to inside cornerH = 3 ft. (Canada) ...... not to be installed above a gas

meter/regulator assembly within3 feet (90cm) horizontally from thecenter-line of the regulator

I = 3 ft. (U.S.A.)6 ft. (Canada) ...... clearance to gas service regu-

lator vent outletJ = 9" (U.S.A.)

12" (Canada) ........ clearance to non-mechanical airsupply inlet to building or thecombustion air inlet to any otherappliance

K = 3 ft. (U.S.A.)6 ft. (Canada) ......... clearance to a mechanical

air supply inletL** = 7 ft. ......................... clearance above paved

sidewalk or a paved drivewaylocated on public property

M*** = 18" ......................... clearance under veranda,porch, deck or balcony

N = 12” ......................... non-vinyl sidewalls12” ......................... vinyl sidewalls

O = 24” ......................... non-vinyl soffit and overhang60” ......................... vinyl soffit and overhang

P = 8 ft.

** a vent shall not terminate directly above a sidewalk or paveddriveway which is located between two single family dwellingsand serves both dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open ona minimum of 2 sides beneath the floor.

NOTE 1: On private property where termination is less than 7 feetabove a sidewalk, driveway, deck, porch, veranda or balcony, use ofa listed cap shield is suggested.

NOTE 2: Termination in an alcove space (spaces open only on one sideand with an overhang) are permitted with the dimensions specified forvinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimumbetween termination caps. 2. All mechanical air intakes within 10 feetof a termination cap must be a minimum of 3 feet below the terminationcap. 3. All gravity air intakes within 3 feet of a termination cap must bea minimum of 1 foot below the termination cap.

(See Note 1)

(See Note 1)

S = 6" .......................... clearance from sides of elec-trical service

T = 12" ......................... clearance above electricalservice

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

QMIN RMAX

1 cap 3 feet 2 x Q ACTUAL

2 caps 6 feet 1 x Q ACTUAL

3 caps 9 feet 2/3 x Q ACTUAL

4 caps 12 feet 1/2 x Q ACTUAL

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

(See Note 5)

(See Note 5)

NOTE 3: Local codes or regulations may require differentclearances.

NOTE 4: Termination caps may be hot. Consider their proximity todoors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere withaccess to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permittedin screened porches. You must follow side wall, overhang andground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screenedporches. Vent system termination is permitted in porch areaswith two or more sides open. You must follow all side walls,overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper perfor-mance of the fireplace when the venting system does not meetthese requirements.

DE

BL

v

v v

v

v

v

v

v

BB

A H

MX

J or K

I

A

G

F

U.S.(3 FT)B

ON

PR

Q(See Note 2)

ElectricalService

V

SV S

V

T

D*

V

Page 23: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 23

For Vertical Terminations - To locate the vent andinstall the vent sections:• Locate and mark the vent centerpoint on the underside

of the roof, and drive a nail through the centerpoint.

• Make the outline of the roof hole around the centerpointnail.

• The size of the roof hole framing dimensions depend on thepitch of the roof. There MUST BE a 1-inch (25.4mm) clear-ance from the vertical vent pipe to combustible materials.

• Mark the roof hole accordingly.

• Cover the opening of the installed vent pipes.

• Cut and frame the roof hole.

• Use framing lumber the same size as the roof raftersand install the frame securely. Flashing anchored to theframe must withstand heavy winds.

• Continue to install concentric vent sections up throughthe roof hole (for inside vent installations) or up past theroof line until you reach the appropriate distance abovethe roof (for outside terminations).

WARNING: MAJOR U.S. BUILDING CODESSPECIFY MINIMUM CHIMNEY AND/OR

VENT HEIGHT ABOVE THE ROOF TOP. THESE MIN-IMUM HEIGHTS ARE NECESSARY IN THE INTER-EST OF SAFETY. SEE THE FOLLOWING DIAGRAMFOR MINIMUM HEIGHTS, PROVIDED THE TERMI-NATION CAP IS AT LEAST TWO (2) FEET FROM AVERTICAL WALL AND 2-FEET BELOW A HORIZON-TAL OVERHANG.

NOTE: This also pertains to vertical vent systems in-stalled on the outside of the building.

!

To seal the roof hole, and to divert rain and snow from thevent system:

• Attach a flashing to the roof using nails, and use a non-hardening mastic around the edges of the flashing basewhere it meets the roof.

• Attach a storm collar over the flashing joint to form awater-tight seal. Place non-hardening mastic around thejoint, between the storm collar and the vertical pipe.

• Slide the termination cap over the end of the vent pipeand rotate the pipe clockwise 1/4 turn.

Step 5. Positioning, Leveling, and Securing the FireplaceThe diagram below shows how to properly position, level,and secure the fireplace.

Figure 3.24Proper Positioning, Leveling,and Securing of a Fireplace

• Place the fireplace into position (see Figure 3.24).• Level the fireplace from side to side and from front to

back.• Shim the fireplace with non-combustible material, such

as sheet metal, as necessary.• Secure the fireplace to the framing using nails or screws

through the nailing tabs.

NAILING TABS(BOTH SIDES)

Roof Pitch H (min.) ft.

flat to 6/12 1.0over 6/12 to 7/12 1.25over 7/12 to 8/12 1.5over 8/12 to 9/12 2.0over 9/12 to 10/12 2.5over 10/12 to 11/12 3.25over 11/12 to 12/12 4.0over 12/12 to 14/12 5.0over 14/12 to 16/12 6.0over 16/12 to 18/12 7.0over 18/12 to 20/12 7.5over 20/12 to 21/12 8.0

Figure 3.23 Minimum Height from Roof to Lowest Discharge Opening

HORIZONTALOVERHANG

VERTICALWALL

TERMINATIONCAP

12X

ROOF PITCHIS X/ 12

LOWEST DISCHARGE

OPENING

H (MIN.) - MINIMUM HEIGHT FROM ROOFTO LOWEST DISCHARGE OPENING

2 FT.MIN.

2 FT. MIN.

Page 24: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0624

Step 7. The Gas Supply LineNOTE: Have the gas supply line installed in accordancewith local building codes by a qualified installerapproved and/or licensed as required by the locality.(In the Commonwealth of Massachusetts installationmust be performed by a licensed plumber or gasfitter).NOTE: Before the first firing of the fireplace, the gassupply line should be purged of any trapped air.NOTE: Consult local building codes to properly sizethe gas supply line leading to the 1/2 inch (13mm)hook-up at the unit.This gas fireplace is designed to accept a 1/2 inch (13mm)gas supply line. To install the gas supply line:• A listed (and Commonwealth of Massachusetts approved)

1/2 inch (13mm) tee-handle manual shut-off valve and alisted flexible gas connector are connected to the 1/2inch (13mm) inlet of the control valve. NOTE: If substi-tuting for these components, please consult local codesfor compliance.

• Locate the gas line access hole in the outer casing ofthe fireplace.

• The gap between the supply piping and gas access holecan be plugged with non-combustible insulation to pre-vent cold air infiltration.

• Open the fireplace lower grille, insert the gas supply linethrough the gas line hole, and connect it to the shut-offvalve.

• When attaching the pipe, support the control so that thelines are not bent or torn.

• After the gas line installation is complete, all connec-tions must be tightened and checked for leaks with acommercially-available, non-corrosive leak check solu-tion. Be sure to rinse off all leak check solution followingtesting.

WARNING: THIS UNIT IS NOT FOR USE WITHSOLID FUEL.

Intermittent Pilot Ignition (IPI) SystemThe gas control system used with this model is In-termittent Pilot Ignition (IPI). This system includes a 3Vcontrol valve, electronic module, and intermittent pilot.

!

Step 6. The Gas Control System

Figure 3.25Gas Control System

NOTE:Flames too close to the ceramicinsulators can cause nuisance lock-outs and electrode failure.

IPI IGNITIONFLAME

SENSORROD

Figure 3.26 Gas Supply Line

• At the gas line access hole, use insulation to re-packthe space around the gas pipe.

• Insert insulation from the outside of the fireplace andpack the insulation tightly to totally seal between thepipe and the outer casing.

!

Step 8. Gas Pressure RequirementsPressure requirements for Heat & Glo gas fireplacesare shown in the table below.

Pressure Natural Gas PropaneMinimum 5.0 inches 11.0 inchesInlet Pressure w.c. w.c.Maximum Inlet 14.0 inches 14.0 inchesGas Pressure w.c. w.c.Manifold 3.5 inches 10.0 inchesPressure w.c. w.c.

A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping isprovided on the inlet and outlet side of the gas control for atest gauge connection to measure the manifold pressure.The fireplace and its individual shut-off valve must bedisconnected from the gas supply piping system duringany pressure testing of the system at test pressures inexcess of one-half (1/2) psig (3.5 kPa).The fireplace must be isolated from the gas supply pipingsystem by closing its individual shut-off valve during anypressure testing of the gas supply piping system at testpressures equal to or less than one-half (1/2) psig (3.5 kPa).

USE A WRENCH ON SHUT-OFF VALVE WHEN TIGHTENING GAS LINE

GAS VALVE

FLEXCONNECTOR

MANUALSHUT-OFF VALVE

GAS LINE ACCESS

CONTROLVALVE

WARNING: DO NOT USE AN OPEN FLAMETO CHECK FOR GAS LEAKS.

Page 25: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 25

Step 9. Wiring the FireplaceNOTE: Electrical wiring must be installed by a licensedelectrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF YOUARE ABSENT FOR EXTENDED TIME PERIODS. THISWILL PREVENT ACCIDENTAL FIREPLACE OPERATION.

For Intermittent Pilot Ignition Wiring SystemAppliance Requirements• This appliance REQUIRES 110-120 VAC to operate.

WARNING: DO NOT CONNECT 110-120 VACTO THE GAS CONTROL VALVE OR THE AP-

PLIANCE WILL MALFUNCTION AND THE VALVEWILL BE DESTROYED.

• The gas control system used with this model is (IPI) Inter-mittent Pilot Ignition. This system includes a 3 Volt controlvalve, electronic module, and intermittent pilot.

Optional AccessoriesOptional fan and remote control kits require that 110-120VAC be wired to the factory installed junction box beforethe fireplace is permanently installed.

!

Figure 3.27 Intermittent Pilot Ignition Wiring Diagram

Wall SwitchPosition the wall switch in the desired position on a wall.Using 14 GA or greater (following local codes) wire thewall switch to the wire harness provided. The ground wiremust be securely attached to the ground stud in the junc-tion box. Do not run 110-120 VAC to the valve. This valvesystem runs off of the 3 Volt transformer (see Figure 3.25).CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-TION WHEN SERVICING CONTROLS. WIRING ERRORSCAN CAUSE IMPROPER AND DANGEROUS OPERA-TION. VERIFY PROPER OPERATION AFTER SERVICING.

BLOWER

TRANSFORMER3V

HOT NEUTRAL

OPTIONALBLOWER

LEADS

REM FAN

120 VACJUNCTION BOX

BROWN

BROWN GREEN

ORANGE

BLACK

GROUND TOFIREPLACE

CHASSIS

PILOT ASSEMBLYAND VALVEASSEMBLYMUST BE

GROUNDED(COMMON GROUND

WITH FIREPLACECHASSIS)

WHITE (SENSOR)

ORANGE(IGNITOR)

S

IGNITIONMODULE 3V

SPARK TOPILOT IGNITOR

TO REMOTE, THERMOSTAT

OR WALL SWITCH

BLACKON/OFFSWITCH

ASSEMBLY

VACUUM SWITCH

VACUUM HOSECONNECTION POINT

VACUUM HOSECONNECTION POINT

I

! WARNING: CONTINUOUS 110-120 VAC SER-VICE MUST BE WIRED TO THE FIREPLACEJUNCTION BOX.

Page 26: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0626

Step 10. FinishingFigure 3.29 shows the minimum vertical and correspondingmaximum horizontal dimensions of fireplace mantels orother combustible projections above the top front edge ofthe fireplace. See Figures 1.2 and 3.1 for other fireplaceclearances.Only non-combustible materials may be used to cover theblack fireplace front.

WARNING: WHEN FINISHING THE FIREPLACE,NEVER OBSTRUCT OR MODIFY THE AIR IN-LET/OUTLET GRILLES IN ANY MANNER.

!

Figure 3.29Minimum Vertical and Maximum HorizontalDimensions of Combustibles above Fireplace

NOTE: Sheetrock can be placed on the top edge and sidesof the fireplace (see Figure 3.30).

Figure 3.28Fan Wiring Diagram

NOTE: IF ANY OF THE ORIGINAL WIREAS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE.O

VARIABLE SPEED CONTROL

TEMPERATURESENSOR SWITCH

BLK

BLOWER

BLK

BLK

BLK

HOT NEUTRAL

REM FAN120 VAC

JUNCTION BOX

CEILING

12”11”

10”9”

8”7”

6”36”

12”11”

10”9”8”

7”6”

TOP FRONT EDGEOF NON-COMBUSTIBLE

BOARD

TOP OFUNIT

1-3/4”

FAN

JUNCTION BOXTEMPERATURE

SENSOR SWITCH

SPEED CONTROL(RHEOSTAT)

Page 27: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 27

CAUTION: IF JOINTS BETWEEN THE FINISHED WALLSAND THE FIREPLACE SURROUND (TOP AND SIDES)ARE SEALED, A 300° F. MINIMUM SEALANT MATE-RIAL MUST BE USED. THESE JOINTS ARE NOT RE-QUIRED TO BE SEALED. ONLY NON-COMBUSTIBLEMATERIAL (USING 300° F. MINIMUM ADHESIVE, IFNEEDED) CAN BE APPLIED AS FACING TO THE FIRE-PLACE SURROUND. SEE THE DIAGRAM BELOW.

Hearth ExtensionsA hearth extension may be desirable for aesthetic reasons.However, ANSI or CAN/CGA testing standards do not requirehearth extensions for gas fireplace appliances.

Installing the TrimCombustible materials may be brought up to the specifiedclearances on the side and top front edges of the fireplace,but MUST NEVER overlap onto the front face. The jointsbetween the finished wall and the fireplace top and sidescan only be sealed with a 300° F. (149° C) minimum sealant.Install optional marble and brass trim surround kits asdesired. Marble, brass, brick, tile, or other non-combustiblematerials can be used to cover up the gap between thesheetrock and the fireplace.Do not obstruct or modify the air inlet/outlet grilles. Whenoverlapping on both sides, leave enough space so that thebottom grille can be lowered and the trim door removed.

Step 11. Installing Trim, Logs & Ember Material

Figure 3.30 Sealant Material

Placing the Ember MaterialThe bag labeled Glowing Ember (050-721) is standardglowing ember material. To place the ember material:• Unhook the spring clips around the glass door. Remove

the glass door.• Ember material is to be placed on burner with caution. Do

NOT place ember material over burner port holes. Placeonly dime size pieces along outer edges of port trails (seeFigure 3.31). The bag is for (4) ember applications. Failureto apply ember material as directed could result in poorlighting conditions and sooting problems. Save the remain-ing ember materials for use during fireplace servicing.

Figure 3.31 Placement of the Ember Material

0” GAP

FINISH WALL MATERIAL MAY BECOMBUSTIBLE - TOP AND SIDES

NON-COMBUSTIBLEBOARD 0” GAP

0” GAP 0” GAP

HIGH TEMPERATURE (300 F/149 C MIN.)TOP & SIDE SEAL JOINT

O O

• Replace glass door and spring clips.

• Replace the upper and lower louvers.

INCORRECTEMBER

PLACEMENTCORRECT

EMBERPLACEMENT

FIRSTGRATE BAR

EMBERMATERIAL

Positioning the LogsRefer to the installation instructions that accompany thelogs. Save the Log Instructions with this manual.If sooting occurs, the logs might need to be repositionedslightly to avoid excessive flame impingement.

___________________________________________

Shutter SettingsNG LP

Burner 1/4” 1/2”

Page 28: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/0628

Step 12. Before Lighting the FireplaceBefore lighting the fireplace, be sure to do the following:Remove all paperwork from underneath the fireplace.Review safety warnings and cautions• Read the Safety and Warning Information section at

the beginning of this Installers Guide.Double-check for gas leaks• Before lighting the fireplace, double-check the unit for

possible gas leaks.Double-check vent terminations and front grilles for

obstructions.• Before lighting the fireplace, double-check the unit for

possible obstructions that could be blocking the vent ter-minations or the front grilles.

Double-check for faulty components• Any component that is found to be faulty MUST BE re-

placed with an approved component. Tampering with thefireplace components is DANGEROUS and voids all war-ranties.

• Confirm that 3V transformer is plugged into the junctionbox as shown in Figure 3.27.

• Ensure vacuum hose (telfon tube) is firmly connected atthe vacuum hose connection point on both the blowerand the vacuum switch (see Figure 3.27).

!

!

A small amount of air will be in the gas supply lines. Whenfirst lighting the fireplace, it will take a few minutes for thelines to purge themselves of this air. Once the purging iscomplete, the fireplace will light and will operate normally.Subsequent lightings of the fireplace will not require thispurging of air from the gas supply lines, unless the gasvalve has been turned to the OFF position, in whichcase the air would have to be purged.NOTE: The fireplace should be run 3 to 4 hours on theinitial start-up. Turn it off and let it cool completely. Removeand clean the glass. Replace the glass and run the fireplacefor an additional 8 hours. This will help to cure the productsused in the paint and logs.

GLASS SPECIFICATIONS:

MODEL GLASS TYPEGATEWAY TEMPERED

Heat & Glo fireplaces manufactured with tempered glassmay be installed in hazardous locations such as bathtubenclosures as defined by the CPSC. The tempered glasshas been tested and certified to the requirements of ANSIZ97.1-1984 and CPSC 16 CFR 1202. (Safety Glazing Certi-fication Council SGCC # 1595 and 1597. Architectural Test-ing, Inc. Reports 02-31919.01 and 02-31917.01.)

This statement is in compliance with CPSC 16 CFR Sec-tion 1201.5 “Certification and labeling requirements” whichrefers to 15 USC 2063 stating “…Such certificate shall ac-company the product or shall otherwise be furnished to anydistributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glasswith permanent marking in such locations. Glass meetingthis requirement is available from the factory. Please con-tact your dealer or distributor to order.

Lava RockIf desired, pour the Lava Rock from the plastic bag aroundthe outside of the log grate. DO NOT place any Lava Rockon top of the burner.

During this break-in period it is recommended that somewindows in the house be opened for air circulation. This willhelp avoid setting off smoke detectors, and help eliminateany odors associated with the fireplace’s initial burning.

Step 13. Lighting the FireplaceYou’ve reviewed all safety warnings, you’ve checked thefireplace for gas leaks, you know the vent system isunobstructed, and you’ve checked for faulty components.Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’SMANUAL FOR ALL CAUTIONS, SAFETY, AND

WARNING INFORMATION PERTAINING TO THELIGHTING AND OPERATION OF THE FIREPLACE.

After the InstallationLEAVE THIS INSTALLATION MANUAL WITHTHE APPLIANCE FOR FUTURE REFERENCE.

Page 29: heat n glow gateway fireplace

Heat & Glo • Gateway • 288-900 Rev. S • 3/06 29

4 Maintaining and ServicingYour Fireplace

Fireplace MaintenanceAlthough the frequency of your fireplace servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service technician perform an appli-ance check-up at the beginning of each heating season.See the table below for specific guidelines regarding eachfireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICINGYOUR FIREPLACE.

Replacing old ember materialFrequency: Once annually, during the checkup.By: Qualified service technician.Task: Brush away loose ember material near the burner.Replace old ember material with new dime-size and shapepieces of Glowing Ember (050-721). New ember materialshould be placed on top of the burner along outer edges ofport trails (see Figure 3.29). Save the remaining embermaterial and repeat this procedure at your next servicing.For more information, see Placing Ember Material.

Cleaning Burner and ControlsFrequency: Once annually.By: Qualified service technician.Task: Brush or vacuum the control compartment, fireplacelogs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)Frequency: Annually.By: Qualified service technician.Task: Make a visual check of the straight flame sensor rod(see Figure 3.25). Use emery cloth to carefully remove anyexisting film or white deposits.

Checking Flame Patterns, Flame HeightFrequency: Periodically.By: Qualified service technician/Home owner.Task: Make a visual check of your fireplace’s flame patterns.Make sure the flames are steady - not lifting or floating.See Figures 3.25 and 4.1. The sensor tip should be coveredwith flame.

Checking Vent SystemFrequency: Before initial use and at least annuallythereafter, more frequently if possible.By: Qualified service technician/Home owner.Task: Inspect the external vent cap on a regular basis toensure that no debris is interfering with the flow of air. Inspectentire vent system for proper function.

Cleaning Glass DoorFrequency: After the first 3 to 4 hours of use. As neces-sary after initial cleaning.By: Home owner.Task: Remove and clean glass after the first 3 to 4 hours ofuse. After the initial cleaning, clean as necessary, particu-larly after adding new ember material. Film deposits on theinside of the glass door should be cleaned off using a house-hold glass cleaner. NOTE: DO NOT handle or attempt toclean the door when it is hot and DO NOT use abra-sive cleaners.

Figure 4.1Burner Flame Patterns