HEALTH CARE - USG Boral · PDF fileHealth care Requirements & ... restricted corridors. Clean...

12
HEALTH CARE ACOUSTICAL CEILING TILES

Transcript of HEALTH CARE - USG Boral · PDF fileHealth care Requirements & ... restricted corridors. Clean...

HEALTH CARE ACOUSTICAL CEILING TILES

INTRODUCTION

Health care Requirements & Applications

USG BORAL HEALTHCARE

3

Non-Restricted

Patient care

Dietary & Laundry

Semi-Restricted

Restricted

No requirements

Easily cleanable, acoustic and lay-in

Smooth finish, scrubbable, non-absorptive, non perforated, durable, withstand cleaning with chemicalsWeigh at least 5 kg/sqm or CE grid or hold down clip to prevent the passage of particles from the cavity above the ceiling plane

Same as dietary & laundry areas + Non-reveal and non-textures tiles

Non-acoustic tiles, monolithic with no crack and no perforation.

Lobby, waiting room, rest room and non-restricted corridors

Clean utility/supply, nourishment, Patient rooms, pharmacy, central services, laboratories, nurse stations, work areas for storage and nurseries

Food preparation, food storage, ware washing & laundry areas

Airborne infection isolation rooms, clean corridors, central sterile supply space, NICU, radiographic room, Minor surgical rooms

Operating room, Sterile core and protective environmental rooms

USG Boral offers a wide range of high quality healthcare ceiling system that increase the aesthetic and functional value of your interiors within a modest ceiling budget.

USG Boral’s superior quality healthcare ceiling products are available in standard suspended ceiling systems such as exposed grid / concealed suspension system; custom-made metal ceiling is also available on request to meet the different requirements of architect specification design.

AREA REQUIREMENT ROOM TYPE

Non-Restricted

Patient care

Dietary & Laundry

Semi-Restricted

Restricted

No requirements

Easily cleanable, acoustic and lay-in

Smooth finish, scrubbable, non-absorptive, non perforated, durable, withstand cleaning with chemicalsWeigh at least 5 kg/sqm or CE grid or hold down clip to prevent the passage of particles from the cavity above the ceiling plane

Same as dietary & laundry areas + Non-reveal and non-textures tiles

Non-acoustic tiles, monolithic with no crack and no perforation.

Lobby, waiting room, rest room and non-restricted corridors

Clean utility/supply, nourishment, Patient rooms, pharmacy, central services, laboratories, nurse stations, work areas for storage and nurseries

Food preparation, food storage, ware washing & laundry areas

Airborne infection isolation rooms, clean corridors, central sterile supply space, NICU, radiographic room, Minor surgical rooms

Operating room, Sterile core and protective environmental rooms

AREA REQUIREMENT ROOM TYPE

USG BORAL CEILINGHEALTHCARE

Health care Applications

NP: not permitted X: Acceptable : in certain locations

4

Sonata Healthcare

Halcyon healthcare with back fleece

Cleanroom Class 100 (non-perforated)

Taiga Hygiene

Metal face

Sparta

Clip-in Plain Alum Ceiling

Lay-in Plain Alum Ceiling

NP NP

NP

NP

NP

NP

NP

NP

NP

NP

NP NP

NPNP

NPNP

AREA NON-RESTRICTED

PATIENT CARE AREAS

DIETARY &LAUNDRY

SEMIRESTRICTED RESTRICTED

X XX

X

X X X

X

X

X X

X X

X X

X X

X X

USG BORAL HEALTHCARE CLEANROOM CEILING

5

FUNCTIONAL PROPERTIES

CLEANROOM DEFINITION

CLEANROOM STANDARDS

• Define the space• Acoustical Control• Fire protection + smoke control• Cleanroom / Pressure control rooms (Lab, Data rooms)• Hygiene (kitchens / hospitals)• Moisture control (kitchens / toilets)• Anti-microbial features (hospitals)

Cleanroom is an environment • Typically used in manufacturing, pharmaceutical products, scientific research, aerospace• Engineering applications with a low level of environmental pollutants such as dust, airborne microbes, aerosol particles, and chemical vapors• A cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. • To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5 ųm and larger in diameter, corresponding to an ISO 9 cleanroom• An ISO 1 cleanroom allows no particles, if only 2 particles 0.2 ųm and per cubic meter• Micrometer (ųm) is a metric measurement unit of length

• Federal Standard 209E was superseded by the new ISO 14644-1 international standards. References to FS209E are still used• The “cleanest” cleanroom FS209E is referred to as Class 1 equals to ISO Class 3• Most common, ISO Class 5 equals to FS209E Class 100• The “dirtiest” cleanroom is ISO Class 9 equals to FS209E Class 1,000,000

ISO CLASS 1

ISO CLASS 2

ISO CLASS 3

ISO CLASS 4

ISO CLASS 5

ISO CLASS 6

ISO CLASS 7

ISO CLASS 8

ISO CLASS 9

10

100

1000

10000

100 000

1000000

2

24

237

2370

23700

237000

10

102

1020

10200

102000

4

35

352

3520

35200

352000

3520000

35200000

8

83

832

8320

83200

832000

8320000

29

293

2930

29300

293000

Class 1

Class 10

Class 100

Class 1000

Class 10 000

Class 100000

Class 1000000

ISO CLASS MAXIMUM NUMBER OF PARTICLES IN AIR US FEDERALSTANDAD 209E

PARTICLE SIZE

(Particles in each cubic metre equal to or greater than the specified size)

>0.1ųm >0.2ųm >0.3ųm >0.4ųm >0.5ųm >0.6ųm

USG BORAL CEILINGHEALTHCARE CLEANROOM

6

CLEANROOM DESIGN Considerations / Recommendations

ASTM D2486

ASTM D3273 / ASTM D3274

ASTM D4828

FS 209E

ISD 14644-1

UL 2818

Scrubality (min 1500 scrub Cycle/min

Mold Growth(Rate 1-10)

Washability(Min 1500 Wash Cycle/MIN)

Cleanroom Class (Class 1- 100,000)

Cleanroom Class (Class 1- 9)

Low VOC (Green Guard)

>1500

10(No Growth)

>1500

N.A

Class 5

<9ųg/m3

>1500

10

>1500

N.A

Class 5

<9ųg/m3

>1500

10

>1500

N.A

Class 5

<9ųg/m3

>1500

10

>1500

N.A

Class 5

<9ųg/m3

>1500

10

>1500

10M-100M

Class 5

<9ųg/m3

>1500

10

>1500

N.A

N.A

<9ųg/m3

>1500

10

>1500

N.A

Class 5

N.A

STANDARDSONATAHEALTHCARE

CLEANROOMNON PERFORATED(MIDDLE EAST)

CLEANROOMNON PERFORATED(USG) METAL FACE

HALCYON HEALTHCARE

TAIGA HYGIENE SPARTA

CLASSIFICATION OF LABORATORIES

TEST COMPLIANCES

• PHYSICAL CONTAINMENT LEVEL 1 (PC1)A Physical Containment Level 1 laboratory is suitable for work with microorganisms where the hazard levels are low, and where laboratory or facility personnel can be adequately protected by standard laboratory practice. The organisms used should generally be classified as Risk Group 1. Specimens that have been inactivated or fixed may be handled in PC1 facilities

• PHYSICAL CONTAINMENT LEVEL 2 (PC2)A Physical Containment Level 2 laboratory is suitable for work with material likely to contain microorganisms that are classified as Risk Group 2 microorganisms. If working with specimens containing microorganisms transmissible by the respiratory route or if the work produces a significant risk to humans or the environment from the production of infectious aerosols

COMPARISON CHART HEALTHCARE - CLEANROOM TILES

• Low VOC Emission (Green Guard Gold Certification) per UL 2818• ISO Clean Room Class 100 per FS 209E and Class 5 as per ISO 14644-1• Anti Microbial resistance per ASTM D3273 (Mold growth) and classified per ASTM D3274• Scrubbability per ASTM D2486• Washability per ASTM D4828

PRODUCT INFORMATION

PRODUCT INFORMATION

APPLICATION

APPLICATION

USG BORAL HEALTHCARE CLEANROOM CEILING

7

SONATA HEALTHCARE

• Water-repellent membrane-top & bottom surface• Durable and cleanable• High NRC (0.7) High CAC(37 dB)• High LR (0.89)• Low-VOC emissions • High Impact and scratch resistance• Surface Washable • Antimicrobial treatment

• Executive Offices and Conference rooms• Reception areas and Lobbies• Corridors• Dining rooms, kitchens and food-prep areas• Patient Rooms• Nurse Stations

CLEAN ROOM™ NON-PERFORATED

• Embossed, vinyl laminated face with sealed back and edges Firecode basemat • Clean room non-perforated finish• Class 100 (FS 209E) • Class 5 as per ISO cleanroom standard 14644-1• Washable & scrubbable resistance• High humidity resistant and anti-mold, mildew growth

• Sterile rooms• Laboratories• Food/ beverage processing • Emergency rooms• Toilet/Wet rooms• Operating/MRI rooms• Surgical Rooms• Airborne Infection Isolation Rooms

USG BORAL HEALTHCARE CEILING

METAL FACE™

• Embossed, vinyl laminated face aluminum foil back Fire rated• Firecode base-mat• Coordinates visually with Clean room perforated finish• NRC 0.55, CAC 37 • Washable & scrubbable resistance• Resistance to corrosion, soiling, humidity and chlorine vapor

• HIGH Humidity Areas• Laboratories/pharmacies• Nurseries• Corridors/Lobbies• Certain Patient Care area – Waiting rooms• Offices

LOUNA

• Fiber Glass Substrate finished with monolithic Fiber Glass scrim• High NRC (up to 1) • High LR (0.88)• Low-VOC emitting panel solution.• Durable and safely cleaned • High Impact and scratch resistance• Washable & Scrubbable finish

• Waiting Rooms, Nurses stations• Receptions & Lobby Areas

SPECIFICATIONSSYSTEM USG LI 200 LAY-IN

METAL CEILINGS

8

PRODUCT INFORMATION

PRODUCT INFORMATION

APPLICATION

APPLICATION

TAIGA HYGIENE

• Smooth Plain• Taiga Hygiene has been developed to meet the most stringent demand on hygiene and clean ability• Special fungicide treatment • Antimicrobial additive on the face and the back surface• Resistance against the growth of mold and mildew• Scrubbable

• Consulting/Patient/treatment Rooms• Clinics / Laboratories• Work Area for Storage

SPARTA

• PVC Laminated• Aluminum Foil backing (vapor barrier) • Panel stays cleaner longer • Washable Vinyl facing • Scrub resistant

• Laboratories• Leisure/ IT Room• Toilet/Wet Areas

9

USG BORAL HEALTHCARE CEILING

PRODUCT INFORMATION

PRODUCT INFORMATION

APPLICATION

APPLICATION

USG BORALHEALTHCARE CEILING

SPECIFICATIONSSYSTEM USG LI 200 LAY-IN

METAL CEILINGS

PRODUCT INFORMATION

TYPES (CLIP-IN & LAY-IN)

SIZES (SQUARE; RECTANGULAR; PLANK)

METAL PLAIN LAY-IN/CLIP-IN

• Powder Coating Technology• Cleanable• Durable • Antibacterial paint• Cool Shade - innovative and sustainable way to reduce temperatures and energy consumption

300 x 300 MM600 x 600 MM1200 x 1200MM

300 x 1200 MM300 x 1500 MM600 x 1200MMOthers….

10

STO

RA

GE

AR

EA

www.usgboral.comwww.usg.comwww.usgdesignstudio.com

USG Middle East Ltd.

Dammam, Saudi ArabiaTel: +966 13 812 0995Fax: +966 13 812 1029e-mail: [email protected] [email protected]

Jeddah, Saudi ArabiaTel: +966 12 639 2172 +966 12 691 0251Fax: +966 12 682 3711e-mail: [email protected]

Riyadh, Saudi ArabiaTel: +966 11 291 8351 +966 11 291 8923Fax: +966 11 291 8894e-mail: [email protected]

Dubai, U.A.E.Tel: +971 4 379 0808Fax: +971 4 388 1305e-mail: [email protected]

Manama, BahrainTel: +973 17 581 596Fax: +973 17 581 597e-mail: [email protected]

Beirut, LebanonTel: + 961 4 547081/2/3/4Fax: + 961 4 547085e-mail: [email protected]

Doha, QatarTel: +974 44 318 387Fax: +974 44 982 165e-mail: [email protected]

Istanbul, TurkeyTel: +90 216 290 28 05Fax: +90 216 290 28 05e-mail: [email protected]

USG Boral reserves the right to change specifications or design and supply products which may differ from those described and illustrated without notice and without liability. All weights and measures are nominal.