HBD HV Control and Monitoring System NOW @ PHENIX Manuel Proissl HBD Meeting 12/09/2008.
-
Upload
antonia-gloria-wade -
Category
Documents
-
view
218 -
download
1
Transcript of HBD HV Control and Monitoring System NOW @ PHENIX Manuel Proissl HBD Meeting 12/09/2008.
HBD HV Controland Monitoring System
NOW @ PHENIX
Manuel ProisslHBD Meeting 12/09/2008
OUTLINE
Installation in PHENIX The completed procedure Mainframe Initialization
OUR HV Control Time To Talk: “What Do We Want?”
Forward/Reverse Bias Trip (Peak) Current for GEMs & Mesh P/T Correction Layers / Tables
Coming Up Voltage / Current Calibration Relay Boards, Cabling, MF testing, … HVCV2.0 Distribution
Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008
HBD HV Control & Monitoring System Manuel Proissl Page 2 of 6
INSTALLATION IN PHENIX
December 8th, 2008 – 4PM EST :: HBD HV Control & Monitoring System successfully installed in PHENIX
Due to the HBD Simulation Project, the installation process without big complications!
TS5 has been powered up and connected to the HBD mainframe on the bridge.
The mainframe rack which is shared with the RXNP guys, has been powered up.
ALL 6 Run9-modified 1471Ns, which have been crash tested and prepared for installation since last Thursday continuously day & night, were installed in the 1458HP mainframe.
ALL 40 channels (GEMs & Mesh chn) have been ramped up and measured via Fluke by controlling them one by one through the HV Control System, which was run on a laptop connected to the PHENIX wireless.
The installation channel check procedure automatically ramped & disabled channel by channel after measurement.
The channel check has been completely successful!!!
Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008
HBD HV Control & Monitoring System Manuel Proissl Page 3 of 6
INSTALLATION IN PHENIX
Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008
Channel Check on the Bridge
View onto the HBD from HV Bridge
HBD HV Control & Monitoring System Manuel Proissl Page 4 of 6
OUR HV CONTROL :: FAQ!
How do we want the HBD to operate?
Operational & Standby Voltages Forward & Reverse Bias: dV is set manually by user for key voltages Trip Settings: GEMs (~165mkA?) and Mesh (~20mkA?) HV Control will be connected to the P/T database (update every 2min) and can so
adjust operational/standby voltages based on layers WE need to set automatically!
Questions? Ideas? Comments?
Upgrades For Run9 | PHENIX, BNL HBD HV Control System HBD Meeting :: December 9 th, 2008
HBD HV Control & Monitoring System Manuel Proissl Page 5 of 6
COMING UP
Correction Curves for 1471N Calibration: this week! Relay Board Trip tests in the hall Simulating the HBD with load channel by channel
Distribution / Installation Files for Linux & XP/Vista Platform independence Final installation files with Installation Wizard Expected Date Online: January 2nd, 2009
HBD HV Control & Monitoring System Manuel Proissl Page 6 of 6