Hands-free Switching for Today’s Lifestyle · BK Green Ground White LOAD Hot (Black) Sensor...

4
Leviton’s line of Decora Motion Sensors combine state- of-the-art technology with modern aesthetics to provide optimal management of lighting and motor loads. Choose from Manual-ON (Vacancy Sensor) or Automatic-ON (Occupancy Sensor) switching. These energy-saving sensors are engineered to ensure that lights/motors will turn OFF automatically when motion is no longer detected within the covered range. Applications Bathrooms Garages Hallways Basements Utility/Laundry Rooms Living/Family Rooms Bedrooms Dining Rooms/Kitchens GENERAL OPERATION Leviton’s sensors use passive infrared (PIR) detection technology to monitor a room for occupancy through a segmented lens. MANUAL-ON OPERATION (Vacancy Sensors) Vacancy sensors require the user to manually press the push- button to turn lights ON. The lights will remain ON as long as the device detects activity in the sensor zone. Lights may be manually turned OFF at any time by pressing the push-button. AUTOMATIC–ON OPERATION (Occupancy Sensors) Occupancy sensors switch lights ON automatically when motion is detected. The lights will remain ON as long as the device detects activity in the sensor zone. Lights may also be switched OFF at any time by manually pressing the push-button. Product Bulletin Decora ® Motion Sensors Hands-free Switching for Today’s Lifestyle

Transcript of Hands-free Switching for Today’s Lifestyle · BK Green Ground White LOAD Hot (Black) Sensor...

Page 1: Hands-free Switching for Today’s Lifestyle · BK Green Ground White LOAD Hot (Black) Sensor Neutral (White) Line 120VAC, 60 Hz (Black) Black LOAD White Red Green Ground Single Pole

Leviton’s line of Decora Motion Sensors combine state- of-the-art technology with modern aesthetics to provide optimal management of lighting and motor loads. Choose from Manual-ON (Vacancy Sensor) or Automatic-ON (Occupancy Sensor) switching. These energy-saving sensors are engineered to ensure that lights/motors will turn OFF automatically when motion is no longer detected within the covered range.

Applications BathroomsGaragesHallwaysBasements

Utility/Laundry RoomsLiving/Family RoomsBedroomsDining Rooms/Kitchens

GENERAL OPERATIONLeviton’s sensors use passive infrared (PIR) detection technology to monitor a room for occupancy through a segmented lens.

MANUAL-ON OPERATION (Vacancy Sensors)Vacancy sensors require the user to manually press the push-button to turn lights ON. The lights will remain ON as long as the device detects activity in the sensor zone. Lights may be manually turned OFF at any time by pressing the push-button.

AUTOMATIC–ON OPERATION (Occupancy Sensors)Occupancy sensors switch lights ON automatically when motion is detected. The lights will remain ON as long as the device detects activity in the sensor zone. Lights may also be switched OFF at any time by manually pressing the push-button.

Product Bulletin Decora® Motion Sensors

Hands-free Switching for Today’s Lifestyle

Page 2: Hands-free Switching for Today’s Lifestyle · BK Green Ground White LOAD Hot (Black) Sensor Neutral (White) Line 120VAC, 60 Hz (Black) Black LOAD White Red Green Ground Single Pole

Features and Benefits- Manual-ON or Automatic-ON models available- Screw terminals for easier installation- Variety of models for control of LED, CFL, Incandescent,

Halogen, Fluorescent ballast or Motor loads - Provides 180° Field of View, 900 sq. ft. coverage- Low profile design blends in with walls for a discreet

appearance; fits in a standad wallbox- Ambient light override prevents occupancy sensors

from switching the lights ON when there is ample natural sunlight

- Adjustable delayed OFF time which can be set for 30 seconds, 5 minutes, 15 minutes or 30 minutes

- Neutral wire not required on most models- CA Title 20 Compliant*- Vacancy Sensors can be used to comply with 2019

California Title 24, Part 6 Vacancy Control Device Requirements

- Contemporary styling in line with Leviton’s Decora® line of wiring devices

- Compatible with Decora PlusTM screwless wallplates- Color change kits are available for most models

Typical Specifications Operating: 0 to 40º CNon-Operating –10 to 85º CRelative humidity, Non-Condensing: 20% to 90%

Agency Standards and Compliance- Complies with UL773A- CSA C22.2 NO.205- NOM57- California Title 20- Vacancy sensors can be used to comply with

2019 California Title 24, Part 6 Vacancy Control Device Requirements

- NEC 2017

Warranty InformationFive-year limited warranty

*Items meet California code of regulation Title 20

1.5m5ft

30ft9.1m

30ft9.1m

6ft1.7m

1.8m6ft

5ft1.5m

30ft9.1m

1.4m4ft

8.4m27ft

2.1m7ft

1.5m5ft

1.2m4ft

1.7m6ft

2.6m8ft

Field-of-View (Horizontal)1.5m

5ft

30ft9.1m

30ft9.1m

6ft1.7m

1.8m6ft

5ft1.5m

30ft9.1m

1.4m4ft

8.4m27ft

2.1m7ft

1.5m5ft

1.2m4ft

1.7m6ft

2.6m8ft

Field-of-View (Side, Vertical)

Dimensional DrawingsSensing Area Coverage

1.75(44.5)

4.13(104.8)

3.81(96.8)

3.28(83.3)

0.37(9.3)

1.22(30.9)

2.72(69)

Page 3: Hands-free Switching for Today’s Lifestyle · BK Green Ground White LOAD Hot (Black) Sensor Neutral (White) Line 120VAC, 60 Hz (Black) Black LOAD White Red Green Ground Single Pole

*Items meet California Code of Regulation Title 20 **3-Way with IPV0R or VP0SR Remote Sensors

IPS02 IPV02 IPVN2 IPS05 IPV05 IPS06 IPSD6 IPVD6 IPS15 IPV15

Voltage, frequency120VAC, 60 Hz • • • • • • • • • •

Load Rating

LED 150W 150W 150W 150W 150W 150W 150W 150W 600W 600W

CFL 150W 150W 150W 150W 150W - 150W 150W 600W 600W

Incandescent/Halogen 300W 300W 300W 600W 600W 600W 600W 600W 1800W 1800W

Motor 1/6 hp 1/6 hp 1/6 hp 1/6 hp 1/6 hp - - - 1/2 hp 1/2 hp

Fluorescent Ballast 200VA 200VA 200VA 600W 600W - - - 1800VA 1800VA

Resistive 2.5 amps 2.5 amps 2.5 amps 5 amps 5 amps - - - - -

Mechanical

Neutral Required for Operation No No Yes No No No No No Yes Yes

Ground Required for Operation Yes Yes No Yes Yes No No No No No

Switching Technology Relay Relay Relay Relay Relay Triac Triac Triac Relay Relay

Single Pole/ 3-Way or Single Pole

Single Pole

Single Pole

Single Pole

Single Pole

Single Pole

Single Pole/ 3-Way

Single Pole/ 3-Way

Single Pole/ 3-Way

Single Pole/

3-Way**

Single Pole/

3-Way**

Features

180°, 900 Sq. Ft.Coverage • • • • • • • • • •

Passive InfraredSensing Technology

• • • • • • • • • •

30s, 5m, 15m, 30m Time Delay • • • • • • • • • •

Ambient Light Override • - - • - • • - • -

Auto/Manual ON Auto ON Manual ON

Manual ON Auto ON Manual

ON Auto ON Auto ON Manual ON Auto ON Manual

ON

Dimming - - - - - - • • - -

Certifications

UL • • • • • • • • • •

CA Title 24Code Compliance - • • - • - - • - •

CA Title 20 Code Compliance* • • • • • • • • • •

Environmental

Operating Temperature0°C to 40°C

• • • • • • • • • •

Relative Humidity20% to 90% non-condensing

• • • • • • • • • •

Storage Temperature-10°C to 85°C

• • • • • • • • • •

Specifications At-A-Glance

Page 4: Hands-free Switching for Today’s Lifestyle · BK Green Ground White LOAD Hot (Black) Sensor Neutral (White) Line 120VAC, 60 Hz (Black) Black LOAD White Red Green Ground Single Pole

G-8761E/H20-dp

Wiring Diagrams

Ordering InformationDescription Rating (120VAC) Cat. No. Color

Relay Vacancy Sensor, single pole 180° Field of View, 900 sq. ft. coverage, neutral required

150W LED/CFL, 300W Inc/Halogen, 200VA FL Ballast, 1/6 HP Motor, 2.5A Resistive IPVN2-1L W

Relay Vacancy Sensor, single pole, 180° Field of View, 900 sq. ft. coverage

150W LED/CFL, 300W Inc/Halogen, 200VA FL Ballast, 1/6 HP Motor, 2.5A Resistive IPV02-1L W, T

Relay Occupancy Sensor, single pole, 180° Field of View, 900 sq. ft. coverage

150W LED/CFL, 300W Inc/Halogen, 200VA FL Ballast, 1/6 HP Motor, 2.5A Resistive IPS02-1L W, I, T, G, E, B

Relay Vacancy Sensor, single pole, 180° Field of View, 900 sq. ft. coverage

150W LED/CFL, 600W Inc/Halogen, 600W FL Ballast, 1/6 HP Motor, 5A Resistive IPV05-1L Z

Relay Occupancy Sensor, single pole, 180° Field of View, 900 sq. ft. coverage

150W LED/CFL, 600W Inc/Halogen, 600W FL Ballast, 1/6 HP Motor, 5A Resistive IPS05-1L Z

Occupancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage 150W LED/CFL, 600W Inc/Halogen IPS06-1L W

Dimming Vacancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage 150W LED/CFL, 600W Inc/Halogen IPVD6-1L Z

Dimming Occupancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage

150W LED/CFL 600W Inc/Halogen IPSD6-1L Z

Relay Vacancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage, neutral required

600W LED/CFL, 1800W Inc/Halogen1800VA FL Ballast, 1/2 HP Motor IPV15-1L Z, E

Relay Occupancy Sensor, single pole or 3-Way, 180° Field of View, 900 sq. ft. coverage, neutral required

600W LED/CFL, 1800W Inc/Halogen1800VA FL Ballast, 1/2 HP Motor IPS15-1L Z

Sensor Remote for use with IPV15 and IPS15 Sensors 120VAC IPV0R-1L ZMatching Switch Remote for use with the IPV15 and IPS15 Sensors for 3-way or up to 5 locations; with LED Locator; neutral required

1800W Incandescent,20A Resistive/Inductive, 1 HP @ 120VAC VP0SR-1L Z

Coordinating Switch Remote for use with the the IPV15 and IPS15 Sensors for 3-way or up to 10 locations; neutral required

1800W Incandescent,20A Resistive/Inductive, 1 HP @ 120VAC VP0SR-01 Z

Visit our Website at: www.leviton.com© 2020 Leviton Manufacturing Co., Inc. All rights reserved.

Use Terminal for 3-WayApplications Only.For Single Pole Applications,Do Not Remove This Label.

Hot (Black)

Neutral (White)

Red Black

Black

White

LOAD

Line120VAC, 60 Hz

Sensor

GreenGround

3-Way(BrassScrew)

Hot (Black)

Neutral (White)

LINE/Black

LOAD

Line120VAC

60 Hz

Sensor

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

PigtailGreenGround

LOAD/Red

First Traveler

Second Traveler

Hot (Black)

Neutral (White)

LINE/Black

LOAD

Line120VAC

60 Hz

Sensor

GreenGround

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

Pigtail

First Traveler

Second Traveler

LOAD/Red

Sensor 3-Way Switch

Other colors include White (-W), Ivory (-I), Light Almond (-T), Gray (-G), Black (-E) and Brown (-B).

Color Change KitsDescription Cat. No. Color

Color change Kits for Relay Sensors IPDKT-00 W, I, T, E, BColor change kits available in the following colors: White (-W), Ivory (-I), Light Almond (-T), Black (-E) and Brown (-B).

Sensor

Black

Hot (Black)

Neutral (White)

Line120 VAC, 60Hz

RD WH

BK

Green Ground

White

LOAD

Hot (Black)

Sensor

Neutral (White)

Line120VAC, 60 Hz

(Black)

Black

LOAD

White

Red

Green Ground

Single Pole Single Pole

Use Terminal for 3-WayApplications Only.For Single Pole Applications,Do Not Remove This Label.

Hot (Black)

Neutral (White)

Red Black

Black

White

LOAD

Line120VAC, 60 Hz

Sensor

GreenGround

3-Way(BrassScrew)

Hot (Black)

Neutral (White)

LINE/Black

LOAD

Line120VAC

60 Hz

Sensor

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

PigtailGreenGround

LOAD/Red

First Traveler

Second Traveler

Hot (Black)

Neutral (White)

LINE/Black

LOAD

Line120VAC

60 Hz

Sensor

GreenGround

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

Pigtail

First Traveler

Second Traveler

LOAD/Red

Sensor 3-Way Switch Sensor

BlackBlack

Hot (Black)

Neutral (White)

Use Terminal for 3-Way Applications Only.For Single Pole Applications,Do Not Remove This Label.

Line120 VAC, 60Hz

Line120 VAC, 60Hz

WH

RD

BK

Switch Remote Sensor

WH

YL/RD

BK(unused)

WH

RD 3-Way

BK Hot (Black)

Neutral (White)

RD(unused)

GreenGround

GreenGround

Green Ground

3-Way

White White

LOAD LOAD

3-Way (option 2) 3-Way

Use Terminal for 3-WayApplications Only.For Single Pole Applications,Do Not Remove This Label.

Hot (Black)

Neutral (White)

Red Black

Black

White

LOAD

Line120VAC, 60 Hz

Sensor

GreenGround

3-Way(BrassScrew)

Hot (Black)

Neutral (White)

LINE/Black

LOAD

Line120VAC

60 Hz

Sensor

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

PigtailGreenGround

LOAD/Red

First Traveler

Second Traveler

Hot (Black)

Neutral (White)

LINE/Black

LOAD

Line120VAC

60 Hz

Sensor

GreenGround

GreenGround

3-Way/Brass

3-Way Switch

Common Terminal(Black Screw)

Pigtail

Pigtail

First Traveler

Second Traveler

LOAD/Red

Sensor 3-Way SwitchSensor

BlackBlack

Hot (Black)

Neutral (White)

Use Terminal for 3-Way Applications Only.For Single Pole Applications,Do Not Remove This Label.

Line120 VAC, 60Hz

Line120 VAC, 60Hz

WH

RD

BK

Switch Remote Sensor

WH

YL/RD

BK(unused)

WH

RD 3-Way

BK Hot (Black)

Neutral (White)

RD(unused)

GreenGround

GreenGround

Green Ground

3-Way

White White

LOAD LOAD

3-Way (option 1) Single Pole

Single Pole

Cat. Nos. IPS06/IPVD6/IPSD6 Cat. No. IPVN2Cat. Nos. IPS02/IPV02/IPS05/IPV05

Cat. Nos. IPS15/IPV15