HAMMAR LIFEBUOY RELEASE SYSTEM - … · 2010-05 HAMMAR LIFEBUOY RELEASE SYSTEM REPLACEMENT MANUAL...
Transcript of HAMMAR LIFEBUOY RELEASE SYSTEM - … · 2010-05 HAMMAR LIFEBUOY RELEASE SYSTEM REPLACEMENT MANUAL...
2010
-05 HAMMAR LIFEBUOY RELEASE SYSTEM
REPLACEMENT MANUAL
Specification:• OneERU• Onereleasecord• Onepilotlineforloadingthelifebuoy• Onereplacementmanual• Onemarkinginstruction
Replacement:
1. Securethelifebuoywithacord.ThisisagoodopportunitytotestthelifebuoyfunctionbyactivatingtheReleaseSwitchorpullingthemanualsafetypin.
2. DismounttheERU–usefixedspannersize8.DiscardtheusedERUinanenvironmentallyapprovedmanner.MakesurethatthenewERUiscorrectlymarkedbefore installation.MountthenewERU–donottightenthenuts!
3. Unscrewthelockingscrewforthereleasescrewandremovetheoldreleasecord.Mountthenewreleasecord.TheendsofthereleasecordcanbelockedduringinstallationbypullingthecordendsintotheV-slot.Makesurethatthelengthofthecordis20cmandthatthecordwillbewelllockedbythewasherbeforeyoutightenthelockingscrewagain.
20cm
2010
-05 4. PutalifebuoyintotheGRPholder,butonly2/3intotheholderandthensecureitwithacordorby
hand.UsethesuppliedthinwhitepilotlinetopullthereleasecordthroughtheH20ERUreleaseunit.Makesurethatthelifebuoylineisnotontheoutwardsideofthereleasecord!
5. PullupthereleasecordthroughtheERUholewiththepilotline.Secureitwiththemanualsafetypin.
6. ConnecttheERUcableattheconnectorbox.
7. Thesystemisnowreadytobeused.TheERUshallbechangedaftertwoyearsofservice.