H70 Feature and Testing Guide

8
©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087 FEATURES and TESTING GUIDE: October 13, 2010 Page 1 of 8 CWCH70 - Corsair Hydro Series H70 Advanced technology for cooling the world’s fastest CPUs If you’re serious about high-performance computing and overclocking, you already know that you’ve got to keep your PC’s processor cool. In order to do this you need a CPU cooler that not only outperforms your current heatsink, but also does it quietly. The Hydro Series H70 has been designed to deliver exceptional levels of cooling performance, and to provide significant headroom for overclocking your processor, quietly and reliably. The Hydro Series H70 is an evolution of the award-winning Hydro Series H50, with several significant upgrades that enable it to deliver even greater cooling performance. These upgrades include a thicker 120mm radiator unit (50mm) with a higher heat-exchanging capacity, and a more efficient, low-profile pump/cold-plate unit that can soak up more heat and provide even lower CPU temperatures. The Hydro Series H70 also features two speed-switchable 120mm cooling fans in a push-pull configuration to provide powerful cooling airflow at low noise levels. The Hydro Series H70 is compatible with all current CPU socket designs, including Intel LGA775, LGA1156 and LGA1366, and AMD Socket AM2 and Socket AM3. Corsair Cooling Hydro Series H70 Specifications Corsair Hydro Series H70 120mm Radiator (50mm thickness) Dual 120mm fans in Push-Pull AMD AM2/AM3, Intel 775, 1156, 1366 Low profile pump & copper cold plate Sealed and pre-filled. No maintenance. Radiator Dimensions 120 x 50mm Fan Dimensions 120 x 25mm (per fan) Fan Speeds 1600 or 2000 RPM Air Flow 50.35 61.2 CFM (per fan) Static Pressure 1.8 2.3mm H2O (per fan) Noise Level 26 31.5 dBA (per fan)

description

Good

Transcript of H70 Feature and Testing Guide

Page 1: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 1 of 8

CWCH70 - Corsair Hydro Series H70

Advanced technology for cooling the world’s fastest CPUs

If you’re serious about high-performance computing and overclocking, you already know that

you’ve got to keep your PC’s processor cool. In order to do this you need a CPU cooler that not

only outperforms your current heatsink, but also does it quietly.

The Hydro Series H70 has been designed to deliver exceptional levels of cooling performance, and

to provide significant headroom for overclocking your processor, quietly and reliably.

The Hydro Series H70 is an evolution of the award-winning Hydro Series H50, with several

significant upgrades that enable it to deliver even greater cooling performance. These upgrades

include a thicker 120mm radiator unit (50mm) with a higher heat-exchanging capacity, and a more

efficient, low-profile pump/cold-plate unit that can soak up more heat and provide even lower

CPU temperatures. The Hydro Series H70 also features two speed-switchable 120mm cooling fans

in a push-pull configuration to provide powerful cooling airflow at low noise levels.

The Hydro Series H70 is compatible with all current CPU socket designs, including Intel LGA775,

LGA1156 and LGA1366, and AMD Socket AM2 and Socket AM3.

Corsair Cooling Hydro Series H70 Specifications

Corsair Hydro Series H70

120mm Radiator (50mm thickness)

Dual 120mm fans in Push-Pull

AMD AM2/AM3, Intel 775, 1156, 1366

Low profile pump & copper cold plate

Sealed and pre-filled. No maintenance.

Radiator Dimensions

120 x 50mm

Fan Dimensions 120 x 25mm (per fan)

Fan Speeds 1600 or 2000 RPM

Air Flow 50.35 – 61.2 CFM (per fan)

Static Pressure 1.8 – 2.3mm H2O (per fan)

Noise Level 26 – 31.5 dBA (per fan)

Page 2: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 2 of 8

CWCH70 - Corsair Hydro Series H70

Key Features

120 x 50mm Radiator

The Hydro Series H70 uses a high-quality 120mm radiator unit that is

double the thickness of the radiator used in the Hydro Series H50.

The increased thickness of the radiator unit, compared to the H50,

equates to a larger internal volume and hence higher coolant

capacity. The total surface area of cooling fins is also vastly

increased. Both of these upgrades contribute to significantly higher

cooling capacity compared to the H50 and other high-end HSFs.

Low Profile Pump Unit

The Corsair Hydro Series H70 utilizes a low-profile

pump / cold-plate unit. This compact, high-

performance pump unit not only allows the H70 to

be used in a wide range of systems / chassis, where

the size of many premium HSFs would be prohibitive,

but it also places no stress on the motherboard for

better overall system reliability.

High Performance Copper Cold Plate

The Hydro Series H70 utilizes an improved copper cold

plate, which is directly integrated into the pump unit.

The high-quality cold plate soaks ups heat from the

CPU and dissipates it into the coolant via copper

micro-channels. This provides significantly higher

cooling capacity compared to the Hydro H50 and

traditional heatpipe-based HSFs.

Push-Pull 120mm Fans

The Hydro Series H70 utilizes two high-quality 120mm cooling fans in a push-pull configuration.

The fans are speed-switchable between 2000rpm for maximum cooling performance and

overclocking flexibility, for enthusiasts who want to push their CPUs to the limit, and 1600rpm for

those who want a balance between powerful cooling performance and low sound levels.

Page 3: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 3 of 8

CWCH70 - Corsair Hydro Series H70

Corsair Hydro Series H70 Product Positioning

Corsair has several CPU cooling products, positioned for different end-user needs and

preferences. The Hydro Series H70 has been designed to provide class-leading cooling

performance for enthusiasts who want to overclock their CPUs to high frequencies while

maintaining low noise levels and reliable CPU temperatures.

Compared to other premium coolers, the Corsair H70 has several key advantages:

Higher performance – higher overclocks at lower CPU temperatures

Low Noise – two fans in push-pull allows for high airflow without high fan noise

Greater value - includes two high-performance fans, whereas many premium HSFs lack fans

Lower weight and bulk – puts minimal stress on the motherboard and makes it easier to fit

Compact cooling block – more flexible installs; doesn’t impede other components, such as RAM

The Corsair Hydro H70 offers higher cooling performance, lower noise and better overall system

reliability compared to competing premium CPU cooling solutions.

Corsair Hydro H70 Advantages:

Better performance; lower noise; easier and safer installation; wider chassis support

Page 4: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 4 of 8

CWCH70 - Corsair Hydro Series H70

Installation Tips – Airflow Direction

There are two options for configuring the airflow of the Corsair Hydro Series H70 when you install

it into your chassis. The approach recommended by Corsair is to install the fans so that they draw

in cool air from outside the chassis. This ensures that the delta between the air temperature and

the temperature of the radiator is maximized, which increases cooling performance according to

Newton’s Law of Cooling. This method of installation requires that you adjust the airflow inside the

chassis to ensure that there are sufficient fans exhausting the hotter air inside the case.

Direction of Airflow

Fan Airflow Direction

The arrows on the frame of

the 120mm cooling fans

denote the airflow direction

and direction of fan rotation

Page 5: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 5 of 8

CWCH70 - Corsair Hydro Series H70

The conventional method is to install the fans to exhaust air from the chassis. This method of

installation requires no re-adjustment of the chassis cooling setup, but results in warmer air being

used to cool the H70’s radiator unit. In chassis with poorer airflow this will result in sub-optimal

cooling performance, compared to Corsair’s recommended approach.

Performance Testing

To assess the performance of the Hydro Series H70 compared to other CPU coolers, we need to

perform a CPU stress test in order generate the maximum amount of heat, and then accurately

measure the CPU temperature. The following information is our suggestion of how to perform this

testing process.

For the most consistent results, it’s advisable to test the Hydro Series H70, and any other coolers

used for comparisons, in an air-conditioned / temperature-controlled environment. Failing this,

testing all the coolers on the same day, to ensure the environmental conditions are the same, will

result in the most accurate results.

In situations where the ambient temperature is not fully controlled, we suggest quoting “Delta T”

values, rather than absolute temperatures. The Delta T is the difference between the average CPU

temperature and the ambient temperature. Ambient temperature should be measured with a

separate thermometer placed in a fixed location.

It is also important to test the Hydro Series H70 and other CPU coolers inside a chassis so as to

provide a “real world” assessment of their performance.

CPU stress testing software

Prime 95

Prime95 stresses the CPU by running Fast Fourier Transformations (FFTs), causing the CPU to

operate at its maximum power. Both versions below are multi-threaded, to guarantee all

cores/threads of the CPU are tested.

64-bit and 32-bit versions of Prime95, for Windows, Linux and MacOS platforms, can be

downloaded from here: http://www.mersenne.org/freesoft/

Temperature-logging software

Everest Ultimate

Everest Ultimate includes the facility to log the temperatures of each CPU core in your processor.

A free trial version is available at http://www.lavalys.com/

Page 6: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 6 of 8

CWCH70 - Corsair Hydro Series H70

For Intel processors, RealTemp is also a good choice, as it reads the DTS (Digital Thermal Sensor)

inside Intel CPUs to provide highly accurate results. It also provides a logging facility.

http://www.techpowerup.com/realtemp/

Running a Test

1. Start Everest Ultimate Edition and ensure that the temperature sensor data is being saved.

This can be done by going to the FILE menu, choosing PREFERENCES and then LOGGING

in the list to the left. Click “Log Sensor Readings to HTML log file” and choose a location

where you want to save the files. Next, select the CPU # / Core # options for each of your

CPU cores from the checkmark list and Hit OK.

Logging CPU temperature data using Everest Ultimate Edition

2. Use a stand-alone thermometer or other temperature measuring device to log room

temperature. This is the AMBIENT temperature (tAM).

Page 7: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 7 of 8

CWCH70 - Corsair Hydro Series H70

3. Boot the test PC and leave it idle in Windows for a minimum of 30 minutes, making sure to

record room temperature during this time. This is IDLE temperature.

4. Start Prime95 and select OPTIONS and then

TORTUE TEST from the menu. Select the “In

Place Large FFTs” option and click “Okay”.

5. Allow the CPU to heat up for 60 minutes or until the CPU Core temperatures have reached

a steady value for at least 5 minutes. You can check that the CPU Core temperatures have

stabilized by looking in the HTML output log file. This is the LOAD temperature.

6. Close Everest and then open the HTML Log file. Copy the results from the last 5 minutes of

the test, during which time the temperatures were steady, into a spreadsheet. Calculate the

average CPU temperature using the function “=average (data range)”. This is tAV

Calculate the Delta T.

a. Calculate the CPU DeltaT using the formula tAV - tAM = DeltaT.

Page 8: H70 Feature and Testing Guide

©2010 Corsair Memory, Inc. All Rights Reserved. Document Number: 49-00087

FEATURES and TESTING GUIDE: October 13, 2010 Page 8 of 8

CWCH70 - Corsair Hydro Series H70

b. Record the DeltaT and repeat the process for additional coolers. Measure

(Tambient), in situations where the room temperature is not well controlled.

c. Compare the DeltaT relative to other coolers tested in the same manner, and at

similar room temperatures.

Performance

The following results are indicative of the level of performance that you should expect to see from

the Corsair Hydro Series H70 CPU cooler at full fan speeds. If your results differ significantly from

those shown in the graph below then please contact your local Corsair representative to discuss

the results before publishing your review.

The tests were performed in the manner described above. All data was gathered at an ambient temp of 25 Degrees C, or roughly 77 Degrees F, with a minimum log time of 120 minutes per test.

The above are absolute temperatures logged using the manner described previously. The H50

deltaT was 60C, while the H70 deltaT was a much lower 46.7C. This difference of 13.3C is largest

at overclocked, fully loaded settings. At lower clock speeds and idle temps, the difference is less

pronounced.

Test system:

Intel Core i7-920 processor overclocked to 3.8GHz (20 x 190MHz, 1.34V vcore), Asus Rampage III Extreme Motherboard,

inside an Obsidian 800D case with default fan configuration.

50.00 55.00 60.00 65.00 70.00 75.00 80.00 85.00 90.00

H50

H70

CPU Temperature

H50

H70