Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru...

45
Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule – I Of EOI cum bid Category ItemNo. Instruments with specification Qty 1 Leica Flexline TS02- 7" Total Station 01 2 Elico PE-138 Soil & water Analysis kit, Elico Make 1 3 Elico Double Beam SL 218 Spectrophotometer microprocessor based, PC Controlled, Elico make 01 4 Microscope (H.B) Make –Olympus 100x-1000x 10 5 Research Microscope (CH 20i) 2 6 Dissecting Microscope, 10x and 20x eye piece (cat no. 650) 10 7 Milk Butyrometer (0-10%) 02 Rural Tech. 8 Vaccume pump (Mac Scientific) (RVP 100 Eco with i) Antisuch back walv ii) Moisture trap iii) Vaccume gauge with regulator iv) Vaccume oil 01 Category ItemNo. Instruments with specification Qty 1 UV-Visible Spectrophotometer, Dual beam, 180- 11000nm, Deuterium lamp with computer 02 2. High Sped Cooling Centrifuge, 25000rpm, 15ml and 50ml changeable rotor, Digital display, variable programmer 02 3. Digital pH Meter , Easy, One Button Calibration, Measurement Accuracy to +/- 0.2 mV, Storage of up to 3 Calibration points, Automatic Temperature Compensation, Simultaneous pH, Temperature and Buffer Display, Direct reading of measured value in mV or as pH, Connectors for FET ( Field Effect Transistor ), pH probes and glass membrane pH Electrode. 08 4 Anaerobic System Make III with rubber ring and petri plate carrier 02 5 BOD Incubator Maintainance free, Dimension: Inner- 300x300x350mm, Outer-500x650x750, Capacity-30lt 06 6 Laminar Air Flow, Horizontal, Internal size:6x2x2ft, Main body: Mild steel power coated, Work surface: Completely in stainless steel, HEPA with 99.99% efficiency at 0.3micron, UV: Germicidal, Dynamicaly balanced, Manometer, 100 ft/ min. air vel. Fl. Tube, 100 class cleanless, Velocity- 90'/min± 20, 65dec, noise level, transparent front door, castor wheel, 230v AC power 06 Biotechnology 7. Autoclave Size 45 X 75 cms, Microprocessor Based Processor Controller,Cum Timer With process completion alarm & System cut off with Solenoid seam release valve,Low Water Level Cut off system. 05

Transcript of Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru...

Page 1: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule – I Of EOI cum bid

Category ItemNo. Instruments with specification Qty

1 Leica Flexline TS02- 7" Total Station 01

2 Elico PE-138 Soil & water Analysis kit, Elico Make 1

3 Elico Double Beam SL 218 Spectrophotometer microprocessor based, PC Controlled, Elico make

01

4 Microscope (H.B) Make –Olympus 100x-1000x 10

5 Research Microscope (CH 20i) 2

6 Dissecting Microscope, 10x and 20x eye piece (cat no. 650)

10

7 Milk Butyrometer (0-10%) 02

Rural

Tech.

8 Vaccume pump (Mac Scientific) (RVP 100 Eco with i) Antisuch back walv ii) Moisture trap iii) Vaccume gauge with regulator iv) Vaccume oil

01

Category ItemNo. Instruments with specification Qty

1

UV-Visible Spectrophotometer, Dual beam, 180-11000nm, Deuterium lamp with computer

02

2. High Sped Cooling Centrifuge, 25000rpm, 15ml and 50ml changeable rotor, Digital display, variable programmer

02

3. Digital pH Meter , Easy, One Button Calibration, Measurement Accuracy to +/- 0.2 mV, Storage of up to 3 Calibration points, Automatic Temperature Compensation, Simultaneous pH, Temperature and Buffer Display, Direct reading of measured value in mV or as pH, Connectors for FET ( Field Effect Transistor ), pH probes and glass membrane pH Electrode.

08

4 Anaerobic System Make III with rubber ring and petri plate carrier

02

5 BOD Incubator Maintainance free, Dimension: Inner-300x300x350mm, Outer-500x650x750, Capacity-30lt

06

6 Laminar Air Flow, Horizontal, Internal size:6x2x2ft, Main body: Mild steel power coated, Work surface: Completely in stainless steel, HEPA with 99.99% efficiency at 0.3micron, UV: Germicidal, Dynamicaly balanced, Manometer, 100 ft/ min. air vel. Fl. Tube, 100 class cleanless, Velocity- 90'/min± 20, 65dec, noise level, transparent front door, castor wheel, 230v AC power

06

Biotechnology

7. Autoclave Size 45 X 75 cms, Microprocessor Based Processor Controller,Cum Timer With process completion alarm & System cut off with Solenoid seam release valve,Low Water Level Cut off system.

05

Page 2: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Sterio Microscope ,Trinucular, 25X magnification, Camera attachment

01 8.

Inverted fluorescence microscope 01

9. Electronic Balance Capacity 220 g, Readability 0.001g/1 mg, Tare range (subtractive) 220 g, Response time (avg.) 1.3 s, Repeatability <=± 0.001g/1 mg, Linearity <=± 0.002g/2 mg,

06

10 Colorimeter ( 5 filter), single beam, Halogen lamp, digital display

05

11 Water Bath (circulation system), Digital display, Microprocessor control, Low water level alarm

02

12 Water Bath Incubator Shaker, 12 position, digital display, microprocessor control, Low water level alarm

05

13 Double distillation Unit (water Steel and glass) 10 Ltr /hr 02

14 Tabletop Centrifuge , 10000rpm, digital display, changeable rotor of 1.5 and 15ml)

05

15 Electrophoresis, horizontal and vertical chamber, power pack, 34 well comb in Horizontal and 20 well comb for vertical, Caster, power pack with digital display

06

16 Thin layer Chromatography 2 and 5lt, caster, variable plate dimension

03

17 Deep Frizer (-80oC), Vertical, 3 shelf microprocessor control, allaram

02

18 Cyclo mixer

10

19 Magnetic Stirrer with hot plate

10

20 Hot air Oven 3 shelf, digital display, microprocessor control

06

21 Soxhtel extraction apparatus with 100ml, 250ml and 500ml round bottom flask

06

22 Rotary Shaker removable18 position plate, digital display 05

23

Micropipette 0.1-10ul, 10-100ul, 20-200ul, 200-100ul and 1 to 5 ml

06set

24 Microprocessor controlled Humidity Cabinet with timer 02

25 Gas Chromatograph with NPD, FID, TCD detector 01

26 Bench top Fermenter Cap. 3 & 5 Ltr. 01

27 Orbital Shaker Incubator 20-300rpm, temp range 25-80oC, 12 position, digital display, Microprocessor control, transparent glass chamber

03

28 Homogenizer 06

29 Refrigerator 200 and 400lt 06

30 Speed vacuum dryer 25 - 60 oC, 1.5ml and 15 ml changeable rotor, vaccum pump, transparent loid, digital display, microprocessor control

01

31 Freeze dryer (5 lt), 10 position , vacuum pump, Holder with jar, -45 to -15oC, digital display programmer, microprocessor control.

01

32 2-D gel electrophoresis, with matrix column, gel dryer 01

Page 3: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Category ItemNo. Instruments with specification Qty 1. Anthropometer 5

2. Sliding Caliper (Martin) 5

3. Spreading Caliper (rounded end) 5

4. Spreading Caliper (Pointed end) 5

5. Plastic tape 5

6. Lange Skinfold caliper 5

7. Cubic craniophor 5

8. Tubular craniophor 5

9. Diagraph (martin type) 5

10. Mollison craniophore 2

11. Osteometric table made of PVC 1

12. Martin’s horizontal needle (450mm) 5

13. Mandibulometer 5

14. Hair Colour chart 5

15. Pelvimeter 5

16. Bag to Contain (anthropometer, pelvimeter, spreading and sliding caliper etc.)

2

17. Goniometer (attachable) 5

18. Cubic Dioptrograph 1

19. Caliper checking gauge 2

20. Rectangular Dioptrograph 1

21. Bone Support 5

22. Palatometer 5

23. Orbitometer 5

24. Mustard pad 20

25. Body Fat Monitor (HBF-308 C) 1

26. Magnifying Lens (medium size) 5

27. Ishihara Color Blindness chart 3

28. Digital Weighing Machine 3

29. Rubber gloves-5 50Pairs

30. Mercurial Sphygmomanometer 5

31. Stethoscope (Standard) 5

32. Simple microscope 2

33. Compound microscope 2

34 Antisera pack of Anti A, Anti B and Anti D (each 10 ml) 1

35 Antisera pack of Anti M and Anti N (each 10 ml) 1

36 Finger pricking needles (Lancet) 2 pack

37 Dermatoglyphic ink 2

38 Ink Roller 2

AAnntthhrrooppoolloogg

yy

39 Common household 4oC Fridge for storage of Antisera and other chemicals (265 l)

1

Page 4: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Category ItemNo. Instruments with specification Qty

1 ELISA Reader* (*Requested from past 2 years and is very important for all endocrinology experiments)

2 Spectrophotometer (UV-VIS) Plate and Cuvette

3 Stereo Dissecting Microscope 100X

4 Digital pH Meter , Easy, One Button Calibration, Measurement Accuracy to +/- 0.2 mV, Storage of up to 3 Calibration points, Automatic Temperature Compensation, Simultaneous pH, Temperature and Buffer Display, Direct reading of measured value in mV or as pH, Connectors for FET ( Field Effect Transistor ), pH probes and glass membrane pH Electrode

5 Fine Balance (min. 0.001 mg precision with dual mode)

6 Binocular for field work (4) (100x)

7 Digital Camera (2) for field work. (with extra telescopic lens for capture of bird and distant images)

8 Refrigerated High Speed Centrifuge: Max Speed 14000 rpm, 15ml rotor, CFC free, programmable

9 Water Purification System: Ultrapure water, ASTM type II water, endotoxin and pyrogen free water

10 Autoclave Size 45 X 75 cm, Microprocessor Based Processor Controller, Cum Timer With process completion alarm & System cut off with Solenoid seam release valve, Low Water Level Cut off system.

11 2-D Electrophoresis unit with power supply, strip/capillary based, medium sized

12 Laminar Air Flow, Horizontal, Internal size:6x2x2ft, Main body: Mild steel power coated, Work surface: Completely in stainless steel, HEPA with 99.99% efficiency at 0.3micron, UV: Germicidal, Dynamicaly balanced, Manometer, 100 ft/ min. air vel. Fl. Tube, 100 class cleanliness, Velocity- 90'/min± 20, 65dec, noise level, transparent front door, castor wheel, 230v AC power

13 CO2 Incubator (Haraus or Thermo)

14 Fume Hood

Zoology

15 Sonicator

Page 5: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

16 Table Top refrigerated centrifuge

17 Rotatory Shaker (with slow, moderate and high speed)

18 Orbital Shaker (with slow, moderate and high speed)

19 Magnetic stirrer 2 Liter capacity

20 Glassware and plastic wares, minor instruments

21 Water Bath (circulation system), Digital display, Microprocessor control, Low water level alarm

22 Rat Cage (Poly propylene) 435x290x160mm (n=20)

23 Mice Cage (Poly propylene) 290x220x140mm (n=20)

24 Poly propylene feeding bottle 300ml (n=100)

25 Dissecting Tray with wax 8”x10” (n=25)

26 Dissecting Tray with wax 14”x12” (n=10)

27 Digital Rota rod apparatus Speed (3-25 rpm, 2 compartment type).

28 Rota Rod Two Compartment PI-71

29 Morris Water Maze for rats and mice

30 Glucometer (Accu chek active)

31 Glucometer (Accu chek integra)

32 Glucometer strips(Accu check active strips)

33 Glucometer strips(Accu check integra strips)

Page 6: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Category ItemNo. Instruments with specification Qty

1 Refrigerated High Speed Centrifuge: Max Speed 14000 rpm, 15ml rotor, CFC free, programmable

2 Water Purification System: Ultrapure water, ASTM type II water, endotoxin and pyrogen free water

3 Algal Culture Facility* a. Culture racks (3) b. Air Conditioner, window type (2) c. pH meter, micropipets, microcentrifuge, electronic balance

4 Gas chromatograph with software: routine analysis of plant samples, EP control

5 Photosynthetic analyzer: for measurement of electron transport, quantum yield, photosynthetic efficiency.

6 Electronic balance; max 100 g upto 0.001mg, digital, portable

7 Mastercycler: gradient, 96 wells, peltier -based, open plateform

8 Autoclave; 50 litre capacity, double walled with safety gauze, pressure and time indicator.

9 -200Deep freezer : 300 lt capacity,

10

2-D Electrophoresis unit with power supply, strip/capillary based, medium sized

11 Plant Growth chamber: adjustable rack, light, temperature and humidity control, CFC free

12 Fluorescent Microscope with image analyzer

13 Stereozoom dissecting microscope (Binocular) with camera attachment

14 Dissecting microscope (Binocular)

15 Automated clean bench

16 Flame photometer

17 Fluoride meter

18 Ultra-sonic Processor

19 Rotatory Evaporator

20 Orbital Shaker

21 Bio-fermenter max. 50 litre

22 Shaking water bath

23 Semi-dry blotter

24 Spectrofluoremeter

Botany

25 Microfuge (table top)

Page 7: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Category ItemNo. NAME OF

EQUIPMENT specification Qty

1

HUMIDITY CHAMBER

Humidity & Temperature Control Cabinet (only Heating), Temp. range-Amb. +5 to 60 ˚C. ±1˚C, Humidity-Amb. To 95% ± 3%, Double Walled, Inner Chamber SS 304, Digital Controller cum Indicator, Size: 610x610x610mm

1

2

OVEN

Laboratory electric ovens having digital indicator and safety alarm. Range of temperature 50ºC - 250 ºC. Accuracy ±1ºC. With air circulating fan S.S. Inside size 600x900x450mm.

2

3

REBOUND HAMMER

As per IS 13311 (Part 2) The rebound hammer method could be used for assessing the likely compressive strength of concrete with the help of suitable correlations between rebound index and compressive strength, assessing the uniformity of concrete, assessing the quality of the concrete in relation to standard requirements, and assessing the quality of one element of concrete in relation to another. It should be able to measure the compressive strength of concrete of the range 10 – 70 MPa. The Rebound Hammer consists of a spring controlled mass that slides on a plunger within a tubular housing. The impact energy required for rebound hammers for different applications should in the range of 0.75 to 30 N-m. The rebound hammer should be checked against the testing anvil before commencement of a test to ensure reliable results. The testing anvil should be of steel having Brinell hardness of about 5000 N/mm2.

1

4

ULTRA SONIC PULSE

VELOCITY TEST

As per IS 13311 (Part 1)The ultrasonic pulse velocity method could be used to establish: the homogeneity of the concrete, the presence of cracks, voids and other imperfections, changes in the structure of the concrete which may occur with time, the quality of the concrete in relation to standard requirements, the quality of one element of concrete in relation to another, and the values of compressive strength dynamic elastic modulus of the concrete.Any suitable type of transducer operating within the frequency range of 20 kHz to 150 kHzThe apparatus should be capable of measuring transit times to an accuracy of 1 percent over a range of 20 microseconds to 10 milliseconds. The accuracy of should be 0.2 microsecond. The measurement obtained should not differ from the known value for the reference specimen by more than 0.5 percent.

1

5 Rebar Locator (Profometer)

The instrument should be light weight for the detection and analysis of rebar systems in concrete. It should measure the spacing of reinforcements in reinforced concrete, cover depth of bars and diameters of bars.

1

Civil Eng.

6

ATTACHMENT FOR

MODULUS OF ELASTICITY

TEST FOR CONCRETE

Longitudinal Compressometer: Ref. : ASTM-C469, IS 516 Lateral Extensometer: Ref. : ASTM-C469

1

Page 8: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

7 COMPACTION FACTOR TEST

Ref. Standard IS: 5515. Compaction factor apparatus is complete with hoppers and receiver assembly, tamping rod of 16mm diax60cm long having a hooper and two trowels.

2

8 CONSISTENCY

TESTER OF CONCRETE

Conforming to Ref. Standard IS: 10510, IS:1199, BS: 1881 (Part 104), AASHTO T126, EN. 12350-3 2

9

SELF CONSOLIDATING CONCRETE FLOWABILITY

Ref. Standard - ASTM C1621 J-RINGTEST ,L-BOX, U-BOX, V-FUNNEL, FLOW TABLE FOR SELF COMPACTING CONCRETE

1

10

FLEXURAL TEST OF

CONCRETE ALONG WITH THE MOULDS

Ref. IS 516 Designed to test three specimens simultaneously. An electric motor driven reduction gear unit ensures smooth constant speed and continuous operation. Two rates of travel i.e. 5 cm/min and 1 cm/min are provided. Suitable for operation on 220V, 50 Hz, Singl No. of standard moulds - 03

1

11 CUBE

MOULDS (15 cms)

Ref. Standard: IS:10086, BS:1881, ASTM C31 and ASTM C192, EN 12390-6-2 21

12

CYLINDER MOULDS (15

cms - Diameter, 30 cms - Height)

Ref. Standard: IS:10086, EN 12390-1-2 These moulds are made of cast iron and split into two parts longitudinally.

12

13 CUBE

MOULDS (7.06 cms)

Ref. Standard: IS:10080 21

14

CORE DRILLING

MACHINE FOR CYLINDRICAL

CONCRETE CORES

Heavy duty, pillar type frame with 1500W, single phase,AC motor• Varying cutting feeds provided with water-fed swivelhead which can be connected to suitable water supply.• Provision at base for water collection / drainage• Core preparation from regular and irregular samplesCore size :dia × height, height should be atleast equal to 2 times dia.• Clamping arrangement to hold specimens withregular/ irregular shapes to the base of machine• Three cutting variable speeds. Accessories Core Drilling Machine Core Drilling Bits for 100, 150 and 200 mm dia

1

15 CORE CUTTER OF CONCRETE

Salient Features of core cutter: 1) Table Mounted 2) Stable Construction 3) Feed arrangement for cutting 4) Cooling Water arrangement 5) Heavy duty, AC, single phase motor This unit is designed for cutting and grinding cylindrical rock specimens upto Nx size. The outfit includes 200mm dia diamond impregnated cutter, a fine diamond impregnated grinding wheel, a water supply system and sample holder.

1

IS:3085 No. of Cells - 3 Specimen - Cylinder (10 cms- Diameter and 10 cms- Height)

1

16 PERMEABILIT

Y TEST OF CONCRETE IS:3085

No. of Cells - 3 Specimen - Cube (15 cms)

1

17 Vibrating table Conforming and specifications in accordance to IS 2514, Size 60 cm x 60 cm . Three Phase supply.

1

18 BUOYANCY BALANCE

Used to check the density of hardened concrete specimens like cubes and cylinders. Buoyancy Balance-15 kgx 0.5 kg

1

Page 9: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

19

Working Model of

BENKELMAN BEAM

Salient Features: 1)Light weight aluminium construction 2) Ease of transport 3) Unique telescopic design, simplifying field set up. 4) Compact, thereby reducing the amount of storage space needed. Operating on a simple lever arm principle, the unit consists of a reference Beam, body, two part probe beam and rear zero adjust.

1

20

Working model for Shear Force

and bending moment diagrams

OBJECTIVES a) Calculation of the reactions arising from the static conditions of equilibrium. b) Application of the method of sections to calculate the internal forces and moments under a point load or under a multiple point load c) Calculation of shear force diagram d}Calculation of bending moment diagram SPECIFICATIONS 1) 2 bearing support 2)Loading of beam by 1 to 3 point loads 3)Position of hinge at 1/3 span TECHNICAL DATA 1) Beam- a} total length: 1000mm b}span : 800mm 2)Measuring Ranges- a}shear force -50...+50 N b}steel rule: 1000mm, graduations: 1mmm 3) Set of weights a} 3*1 N hangers b} 12* 1 N c} 9*5 N d} max, weight load per hanger: 20 N DIMENSIONS a} l*w*h:1400*320*600mm

1

21

Working model for Forces on a

suspension bridge

OBJECTIVES a} Familiarisation with a suspension bridge.b} Caculation of supporting cable force.c}Load distribution between roadway support and supporting cable.SPECIFICATIONS a} investigation of suspension bridge in various load cases. b} suspension bridge with 2 supporting cables and roadway.c} 2 supports with force gauge for the roadway. TECHNICAL DATA a}suspension bridge --span: approx. 1050mm --supporting cables sag: approx. 325mm -- dead- weight of roadway: 6N

1

22 Working model

for Influence line on gerber beam

OBJECTIVES a} Familiarisation with a suspension bridge b} Caculation of supporting cable force c}Load distribution between roadway support and supporting cable SPECIFICATIONS a} investigation of suspension bridge in various load cases b} suspension bridge with 2 supporting cables and roadway c}2 supports with force gauge for the roadway TECHNICAL DATA a}suspension bridge --span: approx. 1050mm --supporting cables sag: approx. 325mm -- dead- weight of roadway: 6N b} weight set --4*1N(hangers), 16*1 N, 16*5 N

1

Page 10: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

23 Working model for Three hinge

Arch

OBJECTIVES a}familiarisation with three hinged arch b}determination of influence line for the supports under a moving load SPECIFICATIONS a} investigation of 2 statically determinant 3- hinge arces b} hinged arch with 3 hinges: 1 crown hinge, 2 abutment hinges at the bearing points TECHNICAL DATA a} Aluminium arches-- 2* long: 480mm, total arch length: 960mm --1* short: 230mm, total arch length: 710mm

1

24 Working model

for Parabolic arch

OBJECTIVES a} mechanical properties of the parabolic arch b}difference bt statically determinant and statically indeterminant arches SPECIFICATIONS a}investigation of a parabolic arch, optionally statically determinate b}4 sets of weights to compensate for the reactions of a fixed support TECHNICAL DATA a} parabolic pre-shaped steel arch --length: 960mm --height: 262mm --cross section: 20*6 mm b}weights --11*1N (7+4 hangers) --16*1 N --19*5 N

1

25 Working model for Deformation of straight beams

OBJECTIVES a}Investigation of the deflection for statically determinant and statically indeterminate straight beams b}deflection on a cantilever beam c}Maxwell-Betti coefficients and law SPECIFICATIONS a} 3 steel beams with different cross section b}1 brass and 1 aluminium beam c} 1 support with clamp fixing TECHNICAL DATA a} beam -- length: 1000mm --cross section: 3*20 mm(steel), 4 *20mm(steel), 6*20mm(steel, brass, aluminium) b}frame opening: 1320*480mm DIMENSIONS: a}l*w*h: 1400*400*750mm (frame)

1

26 Working model for Deformation

of trusses

OBJECTIVES a}elastic deformation of truss under point load b}Calculation of support reaction and bar forces c} comparision of measured and caculated deformation SPECIFICATIONS a}investigation of deformation of statically determinate trusses b}2 supports with node discs c} cross arm for lateral stability of truss TECHNICAL DATA a} truss with 19 pvc bars -- height of truss max. 450mm --length of truss max. 900mm

-- angle bt bars 30⁰, 45⁰, 60⁰, 90� WEIGHT ----approx.

14 kg

1

Page 11: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

27

Working model for

Unsymmetrical bending

OBJECTIVES a} familiarisation with the product moment of inertia and second moment of inertia b} Euler/ bernouli equation c}symmetrical bending of beam with I,L,U profile d}unsymmetrical bending of beam with L- profile SPECIFICATION a} experimental unit for general and unsymmetracal bending of straight beams b} 3 beams:; I, L, U profiles c} 2 dial gauges with bracket TECHNICAL DATA a} Aluminium beam--deformed length: 500mm b} eccentricity of load application point: 0....25 mm c} dial gauges : 0....10 mm, graduations: 0.01mm DIMENSIONS: a} l*w*h: 700*350*400 mm

1

28 Strain gauge

training system

OBJECTIVES a} familiarisation with the fundamentals of measuring with strain gauges b} Calculation of mechanical deformations under bending, tension and torsion c} corelation between mechanical strain and electrical resistancein a strain gauge SPECIFICATIONS a}determination of modulus of elasticity on various materials using measuring objects FL 100.01, FL 100.02, FL 100.03 b} Measurement amplifier with 4 digit digital display TECHNICAL DATA a} tension bars --measuring length: 50mm --cross section: 2*10 mm b} bending bars --length: 385mm --cross-section: 5*20 mm c} Frame opening- - w*h: 480*450mm DIMENSIONS : a} l*w*h: 560*410*610mm(frame) b}l*w*h: 600*400*320mm(box)

1

29 TENSILE

TESTING OF CEMENT

Ref. Standard: EN-196-1 Loading speed of the single lever system: 10+/-2 N/Sec Loading speed of the double lever system: 50+/-10 N/Sec Flexure jaw diameter of the loading roller: 10 mm Supporting roller diameter: 10mm Supporting roller diatance: 100mm Baffle plate span: 46mm

1

TELESCOPE Tube length: 157.5MM Image: Erect Effective diameter of objective:

45MM

Magnification: 30x (18x, 36x with optional eyepieces)

Field of view: 1°24' (2.4 m @ 100 m) Resolving power: 2.5" Minimum focusing distance: 1.3m to infinity Reticle illumination: 3-level variable DISTANCE MEASUREMENT Under good conditions No haze with visibility over 40

km With single prism: 2700m With triple prism: 3600m With nine prisms: 4400m

30 TOTAL STATION

Under normal conditions Ordinary haze with visibility

1

Page 12: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

about 20 km With single prism: 2400m With triple prism: 3100m With nine prisms: 3700m ACCURACY Prism/Precise mode: ±(2+2 ppm x D) mm -4 to 14°F (-20 to -10C): ±(4+2 ppm x D) mm 104 to 122°F (40 to 50C): ±(4+2 ppm x D) mm Prism offset: -999 to 999 mm MEASURING INTERVALS² Prism/Precise mode: 3.0 sec Prism/Normal mode: 0.8 sec. ANGLE MEASUREMENT Reading system: Photoelectric detection by

incremental encoder Circle diameter: V:76mm and H: 88mm Minimum display increment 1"/5" AMBIENT TEMPERATURE RANGE

(-40 to 55 C)

TILT SENSOR Type: Dual-axis Method: Liquid-electric detection Compensation range: ±3' Setting accuracy: ±1"/±0.2 mgon LUMI-GUIDE Light source: LED Visible range: 100m Positioning accuracy: 6 cm @ 100 m Beam spread: 1.5°/2.6 m @ 100 m LEVEL VIAL SENSITIVITY Plate level vial: 20"/2 mm OPTICAL PLUMMET Image: Erect Magnification: 3x Focusing range: 0.5 m to Infinity Field of view: 5° DISPLAY/KEYPAD Type: Graphic LCD (256 x 80 pixel)

Backlight: 7-level illumination Keypad: 20 keys POINT MEMORY POWER SUPPLY onboard Ni-Cd battery BC-5

Output voltage: 7.2V DC rechargable

31 AUTOMATIC LEVEL

Packed in fiber case with all standard accessories with export quality telescope alluminium stand packed in water proof canvas cover.

4

32

SIEVE ANALYSIS TEST FOR COARSE

AGGREGATE

SIEVE SIZES RANGING FROM 80MM TO 4.75MM WHICH WILL ENABLE TO CARRY OUT THESIEVE ANALYSIS TEST FOR CORARSE (STONE CHIPPS)AGGREGATE Ref. Standard IS:460 ISS Perforated Plate GI Frame Sieves set

(80,63,40,20, 12.5,10,4.75 & PAN ALL IN MM & 2 SETS)

2 sets

33

PENETRATION

TESTER OF ASPHALT

Ref. Standard IS:1448 (Part 60) (ELECTRICALLY OPERATED

1

34

REDWOOD VISCOMET

ER OF ASPHALT

Ref. Standard IP 70 Electrical Heating, complete with dimmerstat. Used for those oils, the viscosity of which exceeds 2000s.

1

35 SAYBOLT VISCOMET

Ref. Standard ASTM D88, D 244, AASHTO T 72 For the empirical measurement of saybolt viscosity of 1

Page 13: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

ER OF ASPHALT

petroleum products at specified tempertature between 70˚F and 210˚F.

36

STANDARD

VISCOMETER OF

ASPHALT

Ref. Standard IS:1206, IP 72, STPTC. RT 2. RT 3, BS:2000, (Part 72)

1

37

ENGLER VISCOMET

ER OF ASPHALT

Ref. Standard ASTM D 1665, IP 212, BS: 434

1

38 FLOW CUP TESTER OF ASPHALT

Used for approximate measurments of apparent viscosity for control of consistency during manufacture and use of paints, lacquers and viscous products.

2

39

PAVING MIX

TESTS, MARSHAL

L STABILITY

AND COMPACTI

ON OF ASPHALT

Ref. Standard ASTM D 1559, BS: 598-197, EN-12697-34 Sailent Features: Single speed, Bench top load frame Max. loading capacity, 50KN. Geared Screw Jack.

1

40

PAVEMENT CORE

DRILLING MACHINE

OF ASPHALT

Ref. EN 12504-1 Bit diameter: 150 mm Max. depth of core: 400 mm Drill speed: Variable speed from 900 to 1 Drive: 6HP Petrol Engine Guide shafts: 40 mm dia Screwed Spindle: 20 mm dia Water tap: 12mm Drill Wrenches: Included

1

41

BITUMEN COMPACT

OR FOR MODIFIED MARSHALL MOULDS

Ref. Standard ASTM-D5581:1996, D 6926-04 Weight of Rammer-10.2 Kg. Provision for accomodating-6" mould specimen Supplied complete with 6" mould assembly

1

42

SOFTENING POINT

OF ASPHALT

Ref. Standards- IS:1205, ASTM D 36,E 28, IP 198, IP 58, STPTCPT 3, AASHTO T53, BS:2000,EN1427 For determining the temperature at which a sample of bituminous material loaded by a 9.5mm dia steel ball, drops a specified distance when heated under specified conditions.

2

43

BINDER EXTRACTION TEST

OF ASPHALT

Ref. Standards ASTM D 2172, AASHTO T-58, T-164, EN 12697-1 (ELETRICALLY OPERATED)

1

44

DUCTILITY TESTING MACHINE, ELECTRIC

ALLY OPERATED

OF ASPHALT

Ref. Standards IS:1208, ASTM D113, AASHTO T 51 Designed to test three specimens simultaneously. An electric motor driven reduction gear unit ensures smooth constant speed and continuous operation. Two rates of travel i.e. 5 cm/min and 1 cm/min are provided. Suitable for operation on 220V, 50 Hz, Single phase AC supply.

1

45

SURFACE IRREGULARITY TEST

FOR ROADS

AND RUNWAY

Modified Roughness Indicating machine and is based on the principle of a travelling straight edge. It can measure, mark and record irregularities of roads and runways pavements(concrete and bituminous).

1

Page 14: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

46 ASPHALT

MIXER

Ref. Standard EN 12697-35 Machine can be used laboratory mixing of bituminous materials in order to prepare the specimen for test. Technical Specification. Vertical Capacity - 20 lt Horizontal Capacity - 10 lt Temperature range - Room temp to 200 +/- 0.5 C Timer - 0-999 sec Speed of blade - Revolution 42-48 rpm Rotation 70-75 rpm Vertical Heating Power - 3 kW Horizontal Heating Power - 1.5 kW Testing environment - 10 to 40 C & < 80 % RH Power - 415V, 50Hz, 10A, 3ph

1

47 SEDIMENTATION ANALYSIS

Ref. Standard IS: 2720 (Part II ), BS:1377 Andreasen Pipette Stand: 1. Andreasen Pipette. 2. Glass 10 ml. capacity 3. Sedimentation tube 4. Glass 500 ml. capacity.

1

48

CALIFORNIA BEARING RATIO TEST

Ref. Standard IS: 2720 (Part XVI ), BS:1377; 1924 EN 13286-47/ASTM D 1883; AASTHOT 193 Salient Feature: 1. Compact, Bench top design. 2. Rapid Platen Adjustment. 3. Complete with stabilizing bar. 4. Options for mechanical or electronic measurement.

1

49 CONSOLID

ATION TEST

Ref. Standard IS: 2720 (Part XV), IS:12287, BS:1377, ASTM D 2435. Consolidation Apparatus: The standard outfit comprises of a fixed ring type of consolidometer cell for testing specimens of 60mm diax 20mm thick, but the unit is so designed that specimens of varying sizes from 50mm dia to 100mm dia can also be tested.It is supplied with a set of weights to give a total pressure of

10kg/cm2.

1

50 SWELL

PRESSURE

More than 20%of India's surfacial deposits consist of

expansive soil having swell pressure, varying from 1kg/cm2

to as high as 3.5 kg/cm2. These soil deposits heave considerably when they get weight and lose shear strength.

1

51

STANDARD

PENETRATION TEST

Ref. Standard IS:2131, IS:9640 Standard Penetration Test is a powerful tool for measuring the penetration resistance of the ground and for relating it to the degree of compactness of cohesionless soil and consistency of cohesive soil.

1

52

DYNAMIC CONE

PENETRATION TEST

Ref. Standard IS:4968 (Part-1) For determining the resistance of different types of soil strata to dynamic penetration of a 50mm cone and thereby obtain an indication regarding their relative strength or density or both.For shallow depths, generally upto 15m , if the conditions permit, the cone with threads may be used.

2

53

CLOSED-LOOP

MATERIAL

TESTING MACHINE FOR

FRACTURE AND

FATIGUE TEST ON CONCRE

Detailed Specifications: A. Closed-Loop Material Testing Machine The testing system should be servo-controlled, real time closed-loop control with transducer conditioning and function generation to drive various types of servo actuators. It can support up to four channels on one test station. The expected load capacity is 500 kN (max). The equipment should be complete along with all accessories and loading frame adjustable to the concrete specimens as given below.

B. Test Specimens

1. Materials to be tested: Cement based materials, 2. Specimen geometry: Three-point bend geometry,

1

Page 15: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

TE SPECIM

EN

Compact Tension Test and Wedge-splitting test. 3. The machine will be used for the fracture and fatigue

testing on concrete specimens as per following details. For cement based materials the details of testing along with the specimen dimensions and requirements are mentioned as given below.

C. Specimen Dimensions for Fracture/fatigue Test on Concrete

Test specimens mainly used will be made of cement concrete. There are mainly three types of specimens as mentioned below (also Ref. to Figs.1 and 2).

1. Three-point Bending Test: L×D×B(mm): 2. Compact Tension Specimen D×2H×B (mm): Ref. to

ASTM standard E-399.

3. Wedge Splitting Test (WST) specimen D×2H×B (mm): Maximum Dimensions (i) bmax =150 mm, Lmax = 1500 mm, Dmax = 375 mm for three

point bend test (TPBT) specimens. (ii) Dmax = 600 mm, 2Hmax = 720 mm, Bmax = 150-200 mm for

Wedge Splitting Test (WST) specimen and Compact Tension Specimen as shown in Fig.1.

Three sets of moulds for TBPT, CT and WST geometries with each depth of specimen for casting of concrete specimens should also be provided. For example: for TPBT geometry D = 100, 150, 200, 250 and 300 mm with constant thickness up to 150 mm satisfying L = 4D and L = 2.5D (adjustable). For CT or WST specimen, D = 200, 300, 400, 500 and 600 mm satisfying the other dimensions as shown in Fig.1. The complete loading device for CT, TPBT, WST and others testing requirements should be provided (Ref. Fig.2 for example of WST testing arrangement).

L = 4D

a

D

P

b

Fig.1a Three point bending specimen geometry

(i) Longitudinal section

(ii) Mid span cross-section

D

D1 = 1.25D

a

P

P

H1=

0.275D

H1=

0.275D

H =

0.6D

H =

0.6D

Fig. 1b Standard geometry of compact tension specimen

Page 16: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Fig.2 Principle of Wedge Splitting Test (WST)

D. Test Information (a) Types of tests are to be performed: Fracture, Tension,

compression, bend, fatigue, etc (b) We are to obtain the following information from the tests:

Load-displacement in case of uniaxial tensile strength test; Load-displacement curve and its area, Load-Crack Mouth Opening Displacement (CMOD) curve and its area, Loading and unloading curve (P-CMOD) to get compliance values- in case of fracture tests. S-N curve - in case of fatigue test.

(c) The expected loads: 500 kN (max) (d) The test rates/frequencies are required: CMOD rate

=0.001-0.002 mm/s (e) Control mode for the test: Load-CMOD control or Load-

Displacement control (f) Strain measurement/control is also required. The

expected full scale strain should be of 0.005 (g) The test will be performed at ambient conditions. (h) For cement based materials: The testing will be

performed as per the following references. (i) For testing on metals: the ASTM standards E 1820 –

06e1, E 399 – 06e1 should conform.

D

ao

B

2H

D1

Fig. 1c Dimensions of Wedge Splitting Test (WST) specimen

Fig. 1 Three-point bending test, CT and WST Specimens

Page 17: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

1. RILEM Recommendation (TC50-FMC) (1985).

Determination of fracture energy of mortar and concrete by means of three-point bend test on notched beams. Materials and Structures 18, pp. 285-290.

2. RILEM Technical Committee 89-FMT (1990a). Determination of fracture parameters (KIc

s and CTODc) of

plain concrete using three-point bend tests, proposed RILEM draft recommendations. RILEM, Materials and

Structures 23 (138), pp. 457-460.

Category ItemNo. Instruments with specification Qty

1. 3 –phase induction motor with brake drum loading arrangement having 2 nos. linear scales 1HP/415V/1440RPMSquirrel Cage

01

2. 3 – phase Variac Auto Transformer 0-470 volt, 15amp 01

3. DC Shunt Motor 2HP 220volt / 1500 RPM 02

4. DC Shunt Motor 3HP 220 volt coupled with 1.5kw DC Shunt Generator 220V, 1500rpm

01

5. 3 HP / 220 V/ 1500 RPM / SPDP/ Self Fan Cooled / Ins. Cl. ‘B’ / Foot Mounted / Shunt Wound / 220 V Excitation / DC Shunt Motor Coupled to 1.8 KW / 220 V / 1500 RPM/ SPDP/ Ins. Cl. ‘B’/ Foot Mounted / self fan Cooled / DC Shunt Generator. With Base &Coupling.

01

6. 5 HP / 220 V / 1500 RPM / DC Shunt motor coupled with 3 KVA / 415 V / Star connected / Rotor Wound / Stator excited /Separately excited / Manually Regulated / salient Pole Type Alternator with base and couplings.

04

7. 3 HP / 415 V / 1500 RPM / Star connected / Rotor Wound / Stator excited / Separately excited / Manually Regulated / salient Pole Type / Auto synchronous Motor complete with Damper winding for auto induction start. With Mechanical Loading arrangement having 2 Nos. Round dial scales and friction belt for torque measurement

01

8. Auto Transformer – Variac with MS enclosure. Input : 3 Phase / 415 V AC - Output : 0 – 450 V / 3 Phase / 6 A AC

01

9. DOL starter cum Static Excitation Unit for Motor. Input : 3 Phase / 415 V / 3 wire AC - output : 0 – 250 V / 2 A DC for excitation and 415 V / 3 Phase AC for Supply.

01

11 3-point starter for DC Motor 5HP 09

12. Voltmeter MI 0-300/600V 10

13. Voltmeter 0-300 volt MC portable 05

Electrical

Engg.

14. Ammeter 0-2.5 amp MC. Portable 03

Page 18: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

15. Ammeter 0-10 amp.MC portable 04

16. Ammeter 0-5 amp. MC portable 04

17. DC Ammeter : 2.5 / 5 A 02

18. DC Voltmeter : 0-150/300 V 02

19. DC ammeter : 0-1/2 A 05

20. DC ammeter : 0-30A 05

21. AC MI AMMETER (0-5/10A) 06

22. AC MI AMMETER (0-1/2A) 05

23. DC Voltmeter 0-300/600V portable 06

24. Digital Techometer 0-3000rpm Digital (non contact) 10

25. Rheostats 0-300ohms 2A 03

26. Rheostats 0-300ohms 1.4A 08

27. Rheostats 0-200ohms 1.7A 04

28. Rheostats 0-150ohms 5A 04

29. Resistive load (without lamp), 2 KW 1 phase, 230Volts 02

30. Excitation Unit for Shunt Generator. I/P – Single Phase / 230 V AC Output : 0 – 230 V / 2 A DC

04

31. DPST / 10 A Knife Switch with bed 04

32. Wattmeter LPF 300/600 volt, 5/10 amp 02

33. Watt instruments UPF 150/300 volt, 5/10 amp 03

34. Lamp load (without lamp), 2 KW , 1 phase, 230Volts 02

35. Portable 3 Phase- 3 wire / 5 A – 415 V / Power Factor Meter

02

Category ItemNo. Instruments with specification Qty

1

30 MHz Analog Oscilloscope 2 channel four trace, Invert facility in both channels. Time base: 20ns-0.2 S/div, Deflection coefficient 1mV/div to 20 V/div; Triggering: DC-60MHz; Active TV Sync. Sep; Sweep Delay:0.1 µs -100 ms. Alternate triggering, Component tester 2 level calibrator.

05

2

40 MHz Analog Oscilloscope: 2 channels, sensitivity: 1mV; vert and TB accuracy ±2%; Triggering BW: 60 MHz, Alternate triggering, Active Video Sync Separator, X-mag:x10; Hold off: 10:1, with component and conductivity tester & over scan and Uncal LED indicator.

05

3 Digital Storage Oscilloscope, Frequency range: 60MHz; Dual channel; RTS: 400MS/s, Memory: 2.4 Mpoints, Display: color LCD

02

4 Digital Storage Oscilloscope: Frequency Range: 100MHz; Dual Channel; RTS: 400 MS/s, Memory: 2.4 Mpoints; Display: color LCD

02

5

Spectrum Analyzer with tracking generator: Frequency Range: 100 KHz to 1GHz, Amp range: -114 dBm to +20 dBm, RBW: 1kHz-1MHz in 1-3 step, 200kHz(-3dB), Tracking generator: -20dBm/0dBm dual interface: USB/RS-232.

01

Electronics

& Commu.

6 Function Generator, Sweep generator, Freq counter. Function: Sine, Square, Triangular, pulse, ramp DC; Display: LCD; 40MHz external freq counter

02

Page 19: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

7

Function generator: freq range: 0.5 Hz to 10 MHz; Internal Modulation generator; DC offset; AM/FM; Waveforms: Sine, square, triangular, pulse; 40 MHz auto ranging frequency counter

10

8

Digital Multimeter: 4000 counts; Measurement AC/DC voltage, AC/DC current, Resistance, Capacitance, Duty Cycle, Freq, Temperature, Transistor test, Diode test, Continuity test, Continuity Buzzer.

15

9 100 W Digital display, lead free Solder/ 100 W desoldering station

01

10 Anderson Bridge with Headphone 3

11 Maxwell’s Bridge with Head Phone 3

12 De Sauty Bridge with headphone 3

13 Schering Bridge with headphone 3

14 Wein’s Bridge with headphone 3

15 Wein’s Frequency Bridge 3

16 Hay’s Bridge with headphone 3

17 Ballistic Galvanometer 3

18 LCR meter 3

19 LVDT 3

20 Piezo electric transducer 3

21 Thermocouple Temperature Trainer Module 3

22 RVDT 3

23

Xilinx Spartan 3E FPGA Trainer Kit: Features :

Xilinx XC3S250E – PQ208 Spartan 3E FPGA 250K gates, 5, 508 Logic cells, 216K Bits of blockram & 12 dedicated multipliers. 16 Nos. of digital input using slide switches with LED indication 16Nos. Of digital outputs using discrete LEDs 16 x 2 LCD is provided for display the text message. One Reset Switch One switch is provided for giving manual clock FPGA configuration through JTAG port On board Flash Prom XCFO2S Total 158 I/O pins : 124 pins used for integrating peripheral like LED, Switches etc. 4 Nos of 7 segment LED display One relay and Buzzer provided. 4*4 matrix key provided Housed in a sleek plastic cabinet with built in SMPS 5V/2A.

06

24

Universal FPGA/CPLD Trainer:

The universal VLSI trainer consists of a Main board with many peripheral devices like LED, parallel printer port, VGA port etc. The main board has 4 Nos. of 48 pin Euro connector for plugging in the Daughter boards, which contains the FPGA or CPLD of any manufacturer. Universal VLSI Main Board

Features :

Accommodates any 1.2V, 1.5V, 1.8V, 2.5V, 3.3V and

04

Page 20: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

5.0V devices On board programmer Upto 180 user definable Input/output (I/O) pins available. All the on board devices like LED, DIP Switches etc occupies 178 I/O pins. This should be supported by the FPGA or CPLD used in the Daughter board.

On board Feature:

External interface connector VGA Interface & PS-2 Keyboard/Mouse Interface 4x4 Matrix keyboard 20x4 LCD display One 8 bit 8 channel ADC 8 Bit Two channel DAC One RS232 Serial port interface 4 Digit 7 Segment display One parallel printer port 32 Input DIP Switches & 32 Output RED LEDs

25

Xilinx FPGA Piggy back boards: Spartan-3 Piggy back board 400K usable gates Device Used : XC3S400 2MB Flash PROM to configure

02

26

Xilinx FPGA Piggy back boards: Spartan-3E Piggy back board 500K usable gates Device Used : XC3S500E 4MB Flash PROM to configure

02

27

Xilinx CPLD Piggy back board:

Cool runner II CPLD Piggy back board Device used : XC2C256 6000 system gates, 256 Macro cells

02

28

Spartan-6 FPGA Development Board:

Xilinx Spartan-6 LX45 FPGA, 324-pin BGA package

128Mbyte DDR2 16-bit wide data 10/100/1000 Ethernet PHY On-board USB2 ports for programming & data transfer USB-UART and USB-HID port (for mouse/keyboard) Two HDMI video input ports & two HDMI output ports AC-97 Codec with line-in, line-out, mic, & headphone Real time power monitors on all power rails 16Mbyte x4 SPI Flash for configuration & data storage 100MHz CMOS oscillator 48 I/O’s routed to expansion connectors GPIO includes 8 LEDs, 6 buttons, & 8 slide switches

02

29

Universal Trainer / Development System Includes Base System consisting of 208 pin IO on Berg connector, Oscillator with multiple clocks, 8 LEDs Indicator, Hex-Key Pad, 4 nos. 7-Segment Display, 2 x 16 character LCD, 8-bit 4 channel ADC, One 8-bit DAC( ADC/DAC in single I.C.), 1M EEPROM, RTC, Relay and General Purpose Interface for Stepper /D.C. motors etc, Serial and USB Interface with Daughter Board for 89V51RD2

10

Page 21: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

30 Daughter Board for FPGA 3S400 02

31 Daughter Board for ARM LPC2103 02

32 Stepper Motor with Interface Card 02

33 8 bit ADC Module (Parallel ) 02

34 8 bit DAC Module (Parallel ) 02

35 CNC Machine for PCB Manufacturing : 01

Category ItemNo. Instruments with specification Qty

1. Set up for the inertia table experiment consisting of inertia table, stop watch, screw gauge, weights, meter scale, experimental wire, regular body and irregular body

08

2. Set up for the Modulus of Rigidity of the material of the rod consisting of Barton’s apparatus (Horizontal pattern), ½ Kg. weights, screw gauge, meter scale

04

3. Set up for the Modulus of Rigidity of the material of the rod consisting of Barton’s apparatus (vertical pattern), ½ Kg. weights, screw gauge, meter scale

04

4. Set up for the Moment of Inertia consisting of Fly wheel (20 cm diameter), Meter scale, vernier calipers, stop watch, weights

04

5. Set up for the Coefficient of Viscosity of liquid consisting of stoke’s viscometer, stop watch, screw gauge, thermometer, meter scale, steel balls of different size

04

6. Set up for the determination of “g” consisting of Kater’s pendulum (brass) with stand, stop watch, knife edge

04

7. Set up for the Modulus of rigidity of a wire using consisting of Maxwell needle, screw gauge, meter scale, stop watch, physical balance (capacity 500 gm; brass parts), weight box

04

8. Set up for Searle’s apparatus consisting of two identical bars, stop watch, screw gauge, vernier calipers, physical balance

04

9. Set up for cornu’s fringes consisting of traveling microscope movement in x-direction and y-directions, glass plate, wooden box, knife edges, set of weights with hanger, sodium lamp with choke and enclosure for lamp

04

10. Set up for thermo emf of copper constantan using potentiometer consisting of potentiometer, standard Cd cell, thermocouple, high resistance box, rheostat, one way and two way keys

04

11. Set up for Cantilever experiment consisting of rectangular mettalic beam (meter scale), weights with hanger, pin and microscope

10

12. Set up for Co-axial Cylinder method consisting of rotating cylinder arrangement, stop watch, lamp scale arrangement, meter scale

04

Physics

13. Set up for e/m by Thomson method consisting of power supply with high resistance voltmeter for cathod voltage to CRT, a pair of bar magnet, wooden scale, compass

04

Page 22: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

14. Set up for e/m by Helical method power supply, CRT, standard solenoid fitted on wooden base

04

15. Set up for compound pendulum consisting of the 100 cm. bar, stop watch, knife edge, meter scale

06

16. Simple pendulum set up consisting of brass, aluminum and wooden bob of same mass or same dia., meter scale, stop watch

05

17. Spiral spring set up consisting of spiral spring, set of weights, scale pan, pointer, stop watch

10

18. Series LCR circuit set up consisting up resistance, capacitor, inductance, AC moving coil meter for current measurement, AF oscillator

08

19. Set up for self-inductance consisting of post-office box, ballistic galvanometer, stop watch, decimal ohm box, commutator, given inductance, rheostat, taping key, double key, lamp and scale arrangement

04

20. Set up for mutual inductance measurement consisting of ballistic galvano-meter, post office box, lamp and scale arrangement, mutual inductance coil, keys

04

21. Series RC circuit experiment 04

22. Sonometer set up consisting of sonometer, step down transformer, electro magnet, set of weights

08

23. Melde’s experiment set up consisting up tuning fork, stand with pulley, battery eliminator (2 to 12 DC at 2 Amp), meter scale, pan, physical balance with weight box

04

24. Set up for Maxwell’s inductance bridge consisting of two resistance boxes (one 0 to 10000; another 0 to 1000), variable inductance, AF oscillator and head phone

04

25. Set up for Maxwell’s inductance capacitance bridge consisting of AC source (1KHz), Head phone

04

26. Thevenin’s Theorem set up consisting of power supply, moving coil meter, circuit diagram panel

04

27. Norton’s Theorem set up for power supply, moving coil meter, circuit diagram panel

04

28. Set up for Maximum Power Transfer Theorem consisting of power supply, moving coil meter, circuit diagram panel

04

29. Set up for charging and discharging of capacitor consisting of resistance, capacitance, variable DC power supply, circuit panel

04

30. Set up for coefficient of linear expansion of a rod (Gumber’ Apparatus) consisting of boiler, hot plate, rubber tube, regulated power supply, pivoted galvanometer

04

31. Set up for Lee’s disk method consisting of apparatus, two thermometer, stop watch, vernier calipers, screw gauge, hot plate, steam boiler

04

32. Set up for Zener diode characteristic consisting of regulated power supply 0-10 VDC 10 mA

08

33. Set up for Searle’s conductivity apparatus consisting of copper rod, four thermometers, constant water flow arrangement, measuring flask, stop watch, steam boiler

04

Page 23: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

34. Set up for RC filter circuit consisting of circuit diagrams for low and high pass filters, three resistances, three capacitances, AF oscillator, CRO (10 MHz)

04

35. Diffraction set up consisting of diffraction grating (15000 LPI), semi-conductor diode laser (Output power: 2.0 mW; wavelength: 532 nm), power supply, optical bench (2-bar type) with four uprights, screen with holder

04

36. Fraunhoffer diffraction set up consisting of semi-conductor diode laser (Output power: 2.0 mW; wavelength: 532 nm), power supply, at single slit and circular aperture using semi-conductor laser diode diode Laser, power supply, optical bench (2-bar type) with four uprights, circular aperture, holder, screen

05

37. Set up ultra-sonic grating in a liquid (Kerosene oil) by studying the diffraction of light through an ultra-sonic grating. (Quartz crystal) Quartz crystal, spectrometer, RF oscillator, crystal holder, sodium vapour lamp, liquid container

04

38. Set up for thin wire diffraction pattern consisting of semi-conductor diode laser (Output power: 2.0 mW; wavelength: 532 nm), power supply, optical bench (2-bar type) with four uprights, holder, screen

05

39. Set up for Rydberg’s constant consisting of spectrometer, hydrogen discharge tube, high voltage transformer with the help of a spectrometer diffraction grating and hydrogen discharge tube, diffraction grating (15000 LPI)

05

40. Hall effect set up consisting of Ge single crystal (n or p-type), hall probe stand, hall effect set up, digital voltmeter 0-200 mV, constant current generator 0-20 mA, digital gauss meter, electromagnet with power supply

04

41. Four-probe set up consisting of digital constant current power supply 18 V (0-20 mA), multi range digital voltmeter X1 (0-200 mV) and X10 (0-2V), oven (upto 300 C), Ge crystal, four probe setup

05

42. Frank-hertz experimental set up consisting of argon filled tetrod, filament power supply 3.6-4.3 continuously variable, two power supply 1.3-5.0V continuously variable, power supply 0-95 V continuously variable, saw tooth wave form for CRO 20 MHz display (0-80 V), multirange digital ammeter, Frank-hertz setup

05

43. Set up for specific heat of solids consisting of calorimeter with stirrer, steam boiler, thermometer

04

44. Telescope resolving power set up consisting of telescope with rectangular adjustable slit, target slit and travelling microscope (T-shape), table lamp

04

45. Resolving power of prism set up consisting of prism (refractive index:1.65; 32x32 mm), spectrometer (LCE 1 minute), solid hollow prism, mercury vapour lamp (125 watt) with chokes and enclosures

04

46. Glass refractive index set up consisting of spectrometer (LCE 1 minute), prism (refractive index: 1.65; 32x32 mm), solid hollow prism, mercury vapour lamp (125

04

Page 24: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

watt) with chokes and enclosures

47. Nodal slide set up consisting of optical bench (2-bar type with uprights), optical screen, lamp housing, nodal assembly, plane uprights

04

48. Set up for curie temperature for ferro-electric consisting of main unit with digital voltameter (0-9.99 V ac), audio oscillator (1KHz), standard capacitor (pf, nf), PID controlled thermocouple, dielectric cell with two 1” dia. gold plated brass discs

04

49. Set up for curie temperature for ferro-magnetic consisting of main unit, energy regulator controlled furnace, digital thermometer and thermocouple probe, Ferrite sample, beaker and oil

04

50. Demonstration kit for magnetic materials consisting of inhomogeneous magnetic field

04

51. Optical fiber kit consisting of breadboard (600x300 mm), diode laser (3.0 mW) with power supply, laser mount, translation stage with detector, detector with O/P unit, bending loss apparatus, fiber chuck holder, laser fiber coupler

04

52. Absorption spectrum of iodine set up consisting of spectrometer (LCE 1minute), condensing lens with mount, transmission grating 600 lines per mm, glass tube (length 500 mm; dia. 32 mm), table lamp

04

53. Particle size determination set up consisting of diode laser (2mW) with power supply, optical bench (2-bar type; 4 uprights), metallic plates with holders, glass plate with lycopodium powder, short focal length telescope

04

54. Rydberg constant set up consisting of diffraction grating (transmission type), hydrogen discharge tube, spectrometer, high voltage transformer

04

55. Abbe’s Refractometer set up consisting of abbe’s double prism, thermostat, compensator, telescope mirror, limb, reading magnifier, radial arm

01

56. Plank’s Constant set up consisting of photo vacuum tube, halogen tungusten lamp 12V/35 W, five colour filters (635, 570, 540, 500, 460 nm), regulated voltage power supply 15V, digital nanoammeter (1000 micro-ampere to 1 micro-amp.), optical bench

01

57. Set up for Ultrasonic diffraction consisting of high resolution spectrometer (LC 10 sec.), RF oscillator 1MHz-8MHz digital type, liquid tank, crystal with holder

02

58. Glycerin viscosity set up stoke’s viscosity apparatus, stop watch, glass funnel, screw gauge, glycerin, steel balls of different sizes, measuring tape, rubber band of different colours

01

59. Photoconductivity set up consisting of photoresistor in holder (CdS), power supply 12V AC/DC 5 Amp., Lamp housing, convex lens in holder, polarizer and analyzer, optical bench, adjustable slit self centering, regulated power supply 0-16 V DC, digital multimeter, flexible plug lead 50 cm, flexible plug lead 1meter

01

60. Solar cell consisting of solar cell mounted, light source with 80 Watt lamp in box, two meters supplied with 05

Page 25: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

built-in load resistances and suitable leads

61. Set up for dielectric constant consisting of dielectric kit, electrometer amplifier, digital multimeter, power supply (2-12 V AC/DC), high voltage power supply (0-600 VDC), Flexible plug leads

04

62. He-Ne Laser with inbuilt power supply, optical bench, screen, diffraction slides, slit holder, glass scale, slit, clip

04

63. Michelson interferometer consisting of optical ground bed 250 mm, lead screw 200 mm pitch 1 mm, optical mount mirror, beam splitter, compensating plates 45x32x8 mm and 50x35x8 mm, sodium lamp

04

64. Advance spectrometer consisting of spectrometer (LC 20 sec.), sodium light source, prism (EDF; 38 mm), diffraction grating, micrometer slit

01

65. Fabry Perot spectrometer including sodium light complete unit, He-Ne laser with stand, diode laser with power supply, screen

01

66. Set up for Kerr effect consisting of Kerr cell, polarizer, analyzer, object screen, high voltage power supply 0-5kV, one of 20 kV, prism table, optical bench 1m, convex lens in holder, monochromatic light filter, nitrobenzene 500 ml, monochromatic interference filter, flexible plug lead

01

67. Set up for Faraday effect consisting of flint glass with holder, electromagnet with power supply, He-Ne laser, stand rod

01

68. DSB/SSB amplitude modulation & demodulation Trainer kit

01

69. AM/FM Radio Trainer kit 01

70. Set up for Semi-conductor diode characteristics with power supply, 0-1.5 V and 0-10 mA meters, 0-35 V, 0-50 micro-amperemeters

04

71. Set up for determination of band gap consisting of two meters, power supply, PN junction diode, mini heating oven with thermometer

04

72. Charging & discharging of a condenser consisting of IC regulated power supply, workable and 230VAC, three resistances with separate terminals, digital meter and digital stop watch

04

73. Transistor characteristics set up consisting of built-in continuously variable power supplies, meters to monitor voltage and current.

04

74. Digital multimeter hand held (3-3/4 digit) 04

75. CRO 20 MHz dual trace oscilloscope APLAB MODEL 04

76. Set up for FET Characteristics consisting of IC regulated power supplies 0-10 V, 0-15 V continuously variable power supplies, two voltmeters 10V and 15V, one 15 mA ammeter, FET mounted supplied with leads

04

77. MOSFET Characteristics with two regulated power supplies 0-15VDC/150mA and 0-25VDC/150mA, three meters for voltage and current measurement

04

78. Set up for R.F. (L-C) Oscillator (Hartley’s, Colpitt’s, Clapp’s) with DC regulated power supply, components mounted and circuit diagram printed

04

Page 26: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

79. Complete OP-AMP Mathematical operations set up with regulated power supply

08

80. Opto Electronics devices characteristics consisting of power supply and 3 meters (2 multirange)

04

81. Photo transistor trainer with power supply (C.R.) 04

82. Set up for operational amplifier IC741, built-in square and triangular wave generator, buit-in current source

04

83. Double sided adhesive carbon tape for SEM sample

mounting, 6 mm x 20 m on plastic core 02

84. Au sputter coater and vacuum base 220 V 50/60 Hz for

SEM sample coating 01

85. Ultrasonicator size 3.5 litre capacity, water heater 02

86. Ballistic Galvanometer (560 Ohm), Lamp and scale arrangement

4

87. De-Sauty’s bridge, Headphone and oscillator 4

88. Scherring’s bridge, Headphone and oscillator 4

89. Wein’s bridge, Headphone and oscillator, two dial condenser box

4

90.

Anderson bridge for self inductance, Headphone and oscillator

4

91. Babinet compensator with quarter wave plate, sodium light complete set

4

92. Set up for Newton’s ring consisting of six position microscope X-Z motion, complete set of sodium light source, newton’s ring apparatus, wooden reflector, spherometer

4

93. Half-wave, Full-wave, Bridge rectifiers with filters and variable load

4

94. Capacitance substitution box 4

95. Morse key 4

96. Tapping key single contact 4

97. Tapping key double contact 4

98. Self and mutual inductance coil 4

99. Four way key 4

100. Standard resistance (1 ohm) 4

101. Earth inductor 1000 turns 4

102. Vernier calipers 4

103. Screw gauge 4

104. Meter scale 4

105. Digital meter (voltage) 4

106. Digital meter (current) 4

107. Post-Office Box (Manganin Coil) 3- ratio 6

108. Sodium vapour lamp (55 watt), Wooden box, transformer 4

109. Mercury vapour lamp, transformer, Wooden box 4

110. Gauss eyepiece 4

111. Constant deviation spectrograph 4

112. Function generator 4

113. Lissajous figure apparatus 4

114. Travelling microscope 4

115. Biprism Apparatus complete set 4

116. Green Diode laser Pointer 4

117. Red Alcohol thermometer (150C) 10

118. Steam boiler copper (2 liters) 10

Page 27: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

119. G Clamp (4 inches) 10

120. Leads with banana plug 200

121. Leads with banana plug and crocodile clip 200

122. Portable Wheatstone Bridge 06

123. Resistance box plug type (Manganin Coil), 1-10000 ohms, ½” square rod

06

124. Slide wire Rheostats, 10” x ¾” , 100 Ohms , 1.6A 10

125. Tapping Key (Single Contact) 10

126. Tapping Key (Double Contact) 10

127. Plug Key-3way (with brass block of 9 mm) 10

128. Plug Key commutator 4ways circular 10

129. Reversing Key Commutator MIP Type 10

130. DC Galvanometer, MO-65 on stand 10

131. Pendulum Bob or Spheres, 18mm set of 6 10

Slotted Weight i) (20gm X 5)

10

ii) (50gm X 5) 10

iii) (100gm X 5) 10

iv) (500gm X 5) 10

132. Stop Watch (1/10sec, Least Count 0.1sec) 10

133. Spherometer disc type (1/200, 1/100) 10

134. Probe with cryostat [Closed Cycle Variable Temperature Cryogenic System for optical and electrical properties measurements With Fixed Probe Sample holder, Silicon diode temperature sensor etc.]

01

135. Digital image processing microscope [Trinocular Stereo Zoom Microscope]

01

136. High Temperature Horizontal Tubular Furnace with Control Atmosphere cum Vacuum system [Gas Charging ,Rotary pump, Gas control Panel ]

01

137. Digital multimeter [3-5/6 digits, LCD display]

05

138. LCR Meter with accuracy 0.2%, 100Hz to 25 K Hz, 220 V, 50 Hz

02

139 Soldering and Desoldering station, 220 V, 50 Hz, 100Watt, energy saver mode, sensor and heater fail notification

05

140. Function Generator[ 0.3 Hz to 3M Hz, 5 digit display auto ranging 15 M Hz frequency counter

05

141. ITO coated Glass plate, 12”×12”, 1 mm thickness 05

142. F-SnO2 coated Glass plate, 12”×12”, 1 mm thickness 05

143. Substrates, LaAlO3, SrTiO3, Al2O3,YSZ, Polycrystalline alumina, si, Ge, Al, Pt, SiO2, Ti

Each fifty

144. Platinum crucibles 10

145. Cylindrical Ceramic crucibles 20ml, 50ml, 100 ml, 250ml 450ml

Each twenty

146. Conical Ceramic crucibles 20ml, 50ml, 100 ml, 250ml, 450ml

Each twenty

147. High form crucibles 20ml, 50ml, 100ml, 250ml Each twenty

148. Low form crucibles 20ml, 50ml, 100ml, 250ml Each twenty

149. Ceramic discs diameter 20mm, 28mm, 48 mm Each twenty

150. Ceramic Tray 20ml, 30ml, 80ml, 100ml, Each twenty

Page 28: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

151. Ceramic dish 20ml, 40ml, 100ml Each ten

152. Ceramic boat 15ml, 30ml, 40ml Each hundred

153. Die for pellet preparation of diameter 10mm, 12 mm, 18mm, 25mm

Each two

154. Power supply 0-30V with LCD display, constant voltage and constant current mode

05

155. Temperature controller 77K to 500K temperature 05

156. Thermocouples 05

157. PH meter 02

158. Silver paste with thinner 100ml

159. Pure gold wire for coating 20 gram

160. Pure aluminium wire for coating 100 gram

161. Pure silver wire for coating 50 gram

162. Hygrometer 02

163. Quartz boats, quartz plates and quartz tube of dia. 25 mm Each ten

164. Resistance Temperature Detector PRT-100 (Small) 20

165. Silicon diode for low temperature detection 05

166. Electro magnet (Helmholtz coil) with current power supply, 5000 Gauss

01

167. Kenthal wire for furnace fabrication Five kg

168. Borosil glass bottles 25ml, 50ml (1501) Each two hundred

169. Borosil glass 100ml (1501) 100

170. Diamond Glass cutter 05

171. Gamma Area Monitor Sensitivity: better than 100 cpm/microRem/hr, upper range 10mR/hr, logarithmic remote analog output, remote display and remote alarm relay contact, power supply for operating from AC mains (220V).

2

172. X-ray area monitor Sensitive to low-energy (5keV – 200 keV) X-rays, sensitivity better than 1 microRem/hr, readout and alarm, AC mains operations (220V)

2

173. Neutron area monitor Sensitivity: better than 100 cpm/milliRem/hr, energy range: thermal to fast neutrons, remote display and alarm, power supply for operating from AC mains (220V).

2

174. Hand held radiation Survey Meter: Beta/Gamma radiation survey meter, sensitivity: 0.01millRem/hr or 0.1mSv/hr, alarm facility.

2

175. Pocket dosimeter with charger: 0-200 mR full scale; sensitivity to gamma and X-ray; pocket radiation dosimeter charger

4

176. G.M. Counter Standard GM counting system with end window G.M. detector, sliding bench, absorber (aluminum, Lead, Copper etc)

2

177. G.M. Tube (spare tubes) Additional requirement for GM tube only.

2

178. G.M. Counter data communication software 1

179. Rutherford Scattering complete kit setup Specification: A complete kit for Rutherford scattering measurement (including source, detector, vacuum system etc)

1

Page 29: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

180. Alpha Counting System with suitable detectors, like ZnS(Ag). Complete set-up with different options for detectors, like ZnS or similar ones

1

181. Gamma Ray spectrometer System A complete kit (including power supply, high voltage unit, signal processing uints, NaI(Tl) 2”x2” detector, data communication software, if any etc)

1

182. Standard Reference Source box for sealed gamma sources(including 60Co, 137Cs and 152Eu) with activities ~ 1 microCurie

1

183. Standard Reference Source box for beta counting ( activities around 6000 dpm

1

184. Alpha reference set (241Am with source strength ~6000 dpm)

1

185. Lead shielding for storage of sources 1" thick Pb container with cover; Outside dimensions are 3" dia x 5" high

2

186. Lead bricks for shielding , size 1” x 4” x 6” 6

187. VME powered supply/crate VME standard power supply 21 slots for VME modules with pluggable power supplied from AC main source (220V), Must have interface arrangement for remote monitoring and control, e.g., USB etc. Applicable with VME64/VME64X compliant backplane. With +5V, +12V, -12V, and +3.3V (if applicable) total currents are ~ 110-220A, 20-40A, 20-40A, 110-220A (if applicable), respectively.

1

188. VME controller USB compliant, high speed of data transfer rate (typically 30 Mbytes), good memory buffer (~ 128KByte), with driver supporting most common PC platform, like windows XP/vista/7/LINUX etc. NIM/TTL input options.

1

189. VME based ADC Specification: Multi-event peak sensing, input channels >= 8, 12bit or more resolution, fast clear time (~ 600ns order), integral non linearity < 0.2%, differential nonlinearity < 3%

1

190. VME based TDC Specification: Full scale range between 300nano-second to 10 micro-second, 12 bit resolution or more, integral nonlinearity < 0.2% of full scale range, differential nonlinearity < 3%

1

191. VME data acquisition software ( window/LINUX based) 1

Category Item No. NAME OF EQUIPMENT specification Qty

1. Brookfield Viscometer Model LVDV-II+: 15 to 2,000,000 CP.

10

2. Electronic balance AUW 220D 10

3. Digital pH Meter Model AL20 PH 10

4. Microscope with digital camera

Primo star 2

Pharmacy

5. Friability test apparatus Single drum 10

Page 30: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

digital

6. Digital Mechanical Stirrer digital RPM counter 20

7. Hardness tester Monsanto type 20

8. Hardness tester Pfizer type 20

9. UV Spectrophotometer UV-1800 1

10. Analytical Balance (Digital) 0.1mg (Minimum display) model no. AX200

2

11. Rotary vacuum evaporator Code R-2000D, 50-3000ml, 180oC, 2

12. Dissolution apparatus 8 basket 10

13. Disintegration test apparatus Double basket, 250 Watt 5

14. Tablet machine (Automatic) 8 stations, minipress-I 2

15. Autoclave Horizontal (Cylindrical)

K.W. Load 2.0 2

16. Stability Chamber 2

17. Ampoule washing device 2

18. Ampoule filling and sealing machine

1-10ml 2

19. High Precision Water bath (Microprocessor based) with internal water circulating pump

Size 430x230x265 mm, 28L, 1.5 K.W. 10

20. Heating mantles 150ml, 100Watts, 250ml, 150Watts, 550ml, 200Watts

100

21. Semi automatic digital melting point apparatus

Temp. controlled with PT-100 Sensor 20

22. Magnetic stirrer 2 Liter capacity 20

23. Colorimeter Digital auto colorimeter with 8 filters 10

24. Digital Refractometer ABBE fully automatic 2

25. Polarimeter 220 MM with sodium lamp assembly 2

26. MBST3 Electrophoresis

Teaching Kit

107825 2

27. IKT2 Immunoelectrophoresis

Teaching Kit

106127 2

28.

29. MBST2 Molecular Biology

Start up Teaching Kit

107824 2

30. GeNeiTM Agarose Gel

Electrophoresis Teaching

107714 2

31. GFP Cloning Teaching Kit 107387 2

32. UV transilluminator 107172 2

33. Southern Hybridization

Teaching Kit(

106361 2

34. Northern Blotting Teaching

kit

108007 2

35. CHN Elemental Analyser Fully Automated PC controlled Elemental Analyser for Solids, Liquid

1

Page 31: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

and liquid volatile samples. Sample weight Range : 0.02 to 1000

mg. Standard deviatio: ≤0.1% of absolute. Detection range: 0 to 100% for all elements. Be equipped with digital flow sensors for accurate readout of flow. Oxygen intrusion free thermister technology based Temperature stabilised TCD detector. Mass flow controller/electronic flow controller for constant flow of carrier gas.

36. HPLC Quaternary HPLC System with UV

Visible detector, manual injector, Full system Controlled software, HPLC Column & Essential Accessories like UPS, Computer, Printer etc. HPLC COLUMNS:- C18 Column 250 x 4.6 mm

1

37. HPLC Quaternary HPLC System with PDA Detector, manual injector, Full system Controlled software, HPLC Column & Essential Accessories like UPS, Computer, Printer etc. HPLC COLUMNS:- C18 Column 250 x 4.6 mm

1

38. Heating Mantle 100ml x60w, 250mlx150w, 500mlx200w, 1000mlx300w, 2000mlx450w, 3000mlx450w, 5000mlx600w,

50

39. Rat Cage (Poly propylene) 435x290x160mm 100 40. Mice Cage (Poly propylene) 290x220x140mm 100 41. Poly propylene feeding

bottle 300ml 100

42. Dissecting Tray with wax 8”x10” 100 43. Dissecting Tray with wax 14”x12” 100 44. Sherrington

Kymograph 0.12 mm /sec to 640mm/sec,15x15 cm cylinder

30

45. Student Organ Bath 7.5x4.5x5 inch depth 30 46. Thermostatic Organ Bath With electric stirrer 30 47. Pole Climbing Response

Apparatus 440v.0.2 ma at frequency of 5/sec. 2

48. Acto-Photometer 4 Digit second timer 30 cm x30 cm animal cage

2

49. Acto-Photometer 6 Digit activity counter 2 50. Research Analgesiometer

(Tail Flick) With photoelectric tail flick sensor and digital timer

2

51. Research Analgesiometer (Tail Flick, Radient heat type)

Student Model with foot switch and digital time display

2

52. Digital Rota rod apparatus Speed 3-25 rpm,2 compartment type. 2

53. Digital Rota rod apparatus Speed 3-25 rpm,3 compartment type 2

Page 32: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

54. Digital Rota rod apparatus Speed 3-25 rpm,4 compartment type 2 55. Digital Rota rod apparatus Speed 3-25 rpm,5 compartment type 2 56. Digital Rota rod apparatus Speed 3-25 rpm,6 compartment type 2 57. heating mantles CLE-111,500ml 2 58. heating mantles CLE-111,1lt 10 59. Analgesiometer

30*30cmsEddy'S Hot Plate PI-5 5

60. Electroconvulsiometer(4,6,8mm)240V AC PI-41

5

61. Histamine Chamber PI-51 5 62. Rota Rod Two

Compartment PI-71 2

63. Digital Telethermometer CLEM-40 2 64. Soxhlet Extraction Units

(500watt) CLE-125 20

65. Soxhlet Extraction Units (750watt) CLE-125

20

66. waterbath rectangular CLE-104,15lt 10 67. Glucometer (Accu chek

active) 10

68. Glucometer (Accu chek integra)

10

69. Glucometer strips(Accu chek active strips)

10

70. Glucometer strips(Accu chek integra strips)

10

71. Craft's polypropylene animal cages BAC4,435*290*160mm

50

72. Craft's polypropylene animal cages BAC4,290*220*140mm

50

73. 1220 Bottle aspirator 1220029,1000ml 50 74. Mercury metal 2kg 75. Refrigerator 185lt 10 76. Inco New Electrical E-8

Student kymograph MB-132 30

77. Inco simple lever without load screw with writing arm form S.S capilary MF-101

30

78. Inco isotonic load lever with weight with writing arm form S.S capilary MF-113

30

79. Inco simple lever without load screw with writing arm form S.S capilary MF-102

30

80. Inco Starling heart lever ,to fit 9mm rods MF-121

30

81. Inco frog muscle chamber lever from stainless steel capilary light sturdy MF-141

30

82. Inco open sided X block machined from slid brass rod MK-153

30

83.

Inco fine adjustment X MK-158 30

Page 33: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

block permitting fine radical adjustment

84. Inco animal holder for small animal 50mm size ML-176

30

85. Inco animal holder for small animal 62mm size ML-177

30

86. Inco universal acrylic rat restrainer with removable head &tail gates MI-180

30

87. Inco arterial cannula coring glass ML-201

30

88. Inco venous cannula coring glass ML-205

100

89. Inco syme 's perfusion cannula ML-209

100

90. Inco Assembly for perfusion of excised mammalian heart with stainless fittings perspex MM-111

30

91. Inco Assembly for perfusion of excised mammalian heart with double reservoir unit MM-112

30

92. Inco thermostatic Assembly for perfusion of excised mammalian heart MM-115

30

93. Inco student organ bath thermostatic control perpex bath resting on sturdy frame adjustable heating element organ & oxygen tube MM-202

30

94. Inco student organ bath thermostatic control perpex bath with thermostic control,electric stirrer,double set of glass inner vessel oxygen tube MM-321

30

95. Inco miniature aerator for organ baths for 230v. 50Hz heavy duty superior quality MM-235

30

96. organ tube for two unit bath side tube MM-402

100

97. oxygen tube with platinum tip MM-403

100

98. oxygen tube without platinum tip MM-404

100

99. Histone deacetylse (HDAC) inhibition Kit Colorimetric assay kit

05

100. Histone deacetylse (HDAC) inhibition Kit Fluorometric assay kit

05

Page 34: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

101. Digital Melting Point Apparatus

10

102. Ink writing pen complete unit MQ-125

50

103. Rota rod 6 compartment with digital speed control PP-213

10

104. Inco student physiograph two channel amin console with 9 speed chart drive time & event, transducer & stimulator couplers PG-122

20

105. Stoeltings Steeotaxic Apparatus

10

106. Dental Drilling Machine 10 107. Dental Cement 108. Elevated Plus maze for

rat and mice

109. Digital Conditioned Place Preference Apparatus

110. Morris Water Maze for rats and mice

111. Learned helplesness Test Box

05

112. Anxiometer (Vogel Conflict Test)

05

113. Forced Swim Test (Borosil Glass Jars)

05

114. Magnetic Stirrer 50 115. Fear Conditioning

apparatus 05

116. Digital Balance (0.01 mg sensitivity)

05

Category ItemNo. Instruments with specification Qty

Chemical

Engg. 1.

DIGITAL BOMB CALORIMETER :-

WITH SAFETY DEVICE, BOMB CERTIFIED BY RTC. (GOVT. OF INDIA) & WATER JACKET WITH PUFF INSULATION.

Model SI -5 For Determination of Calorific Value of Liquids & Solids. Digital bomb calorimeter provides simple and expensive method for determination of heat of combustion of organic matter and the calorific value & Sulphur content of solid & liquid fuel. The out fit supplied is complete for analysis as per

1

Page 35: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

the method recommended by British standard institution BS1016. All part of out fit have been finished & tested according to the specification laid down by institute of petroleum and British standard institution TESTING OF BOMB Each bomb is tested before it leaves the factory, in accordance with the requirement of the institute if petroleum (LT.12/63 T) and work certificate is issue with each bomb. This certificate gives the result of hydraulic testing under pressure of 300 atmospheres (4400 p.s.i.) maintained for a period of ten minute with out a sign of leakage. the maximum deformation must not exceed the specified limits combustion bomb certified by national test house / regional testing center / any other reputed institute can be supplied on extra charge CALORIMETER VESSELS The vessels is made up of copper and chromium plated it include a bomb support that insure proper positioning of bomb in the vessels. WATER JACKET The outer container of jacket is made up of copper and is chromium plated both inside and outside or S.S the top is closed by a bakelite cover. A terminal block is fitted on the top of the container so that connection can be made from the firing control. OFFSET STIRRER The stirring mechanism supplied gives sufficient turbulence for effective stirring, while no heat is imparted to calorimeter water. It consist of an impeller driven by stirrer at a constant speed the offset arrangement whereby the motor drives the impeller via belt preclude any possibility of heat transference between motor and calorimeter vessels contents. ELECTRONIC FIRING UNIT WITH DIGITAL ] BECHKMAN THERMOMETER The unit incorporates a digital thermometer for

Page 36: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

precise measurement of rise the temp. and an electronic circuitry that provide an electrical mean for firing the samples socket for stirrer & terminal for fuse wire also provide at the back side of the unit CRUCIBLE Various type of crucible are available but the standard supplied with outfit being stainless steel crucible of 8 ml. capacity which fits in the standard support ring provide with the outfit.

2. pH METER :-

Model No. :- SI - 10 With Automatic Temperature Compensation, combination pH electrode and RTD probe, 3½ Digit LED display. Useful for pH and Redox Potential Measurement (Table Model)

1

3. DIGITAL CONDUCTIVITY METER :- Model No. :- SI – 16 3 ½ digit LED display with facility for temperature compensation and digital cell constant adjustment along with conductivity cell & other accessories (Table Model)

1

4. REDWOOD VISCOMETER (IP 70) These viscometers are designed for viscosity tests of petroleum products which react as Newtonian liquids at the test temperature. They confirm to requirements of IP 70. Two adaptation of Redwood Viscometer are available. No. 1 for liquids having Redwood flow 20 seconds to 2000 seconds and No. 2 for liquids whose flow time with No. 1 exceeds 2000 seconds. The complete outfit comprises stainless steel bath having drain plug with Elect. heating arrangements (suitable to operate at 220 Volts 50 Hz AC Mains) or Gas Heating arrangements with tap, silver plated oil cup with precisions stainless steel jet, ball valve, cover, thermometer clip, stirrer and suitable stand with leveling screws. REDWOOD VISCOMETER NO. 1

• Electric Heated Model with Energy Regulator control

• Electric Heated with Voltage varrier Copper

coil type

1

Page 37: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

REDWOOD VISCOMETER NO. 2

• Electric Heated Model with Energy Regulator control.

• Electric Heated with Voltage varrier Copper coil type

5. CLEAVELAND FLASH POINT & FIRE POINT

APPARATUS

• Cleaveland Flash Point Apparatus Elect.

heated combined test system either test by Gas

Jet or by Oil Wick arrangement with

Concealed Hot Plate with Digital Temp.

Indicator This apparatus is used for determination of flash point and fire point of petroleum products except fuel oil with open cup flash above 80° C as per specification IP 36 and IS : 1448 (P : 69) 1969. The apparatus consists of a cup, heating plate to specific dimension, and thermometer clip and test flame attachment with swivel joint for passing over test liquid surface in the prescribed manner. Heating is controlled by means of energy regulator fitted to the apparatus. Suitable for operation on 220 Volts 50 cycles AC Circuits.

1

6. CLOUD AND POUR POINT APPARATUS (IP 15, ASTM-D97/57 and IS 1448-1970)

• Cloud & Pour Point two Test insulated body

• Cloud & Pour Point Apparatus Four test This is made as specified by IP-15, ASTM-D-97/57 & IS-1448-1970. The Pour point is the lowest temperature at which the oil will just fail to flow. The apparatus consists of main cooling bath made of stainless steel sheet and stand unit with drain plug and cover with provision for fitting thermometer and filling aperture for adding freezing mixture.

1 1

7. BOD INCUBATOR :- This is special type of incubator designed to meet the requirements for incubation of biochemical Oxygen demand (BOD) on water and sewage. Also recommended for preservation of vaccines at low temperature and supply of endymatic digestion Processes and other tests demanding constant and uniform low temperature. The unit is highly suitable for work at Temperature below as well as above the ambient. Our BOD incubator is being also used as Environmental Study and Growth

1

Page 38: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Chambers by incorporating Lighting & cooling and heating systems. Inside walls are of Stainless Steel. Out Side of mild steel. Finished in attractive white enamel. Mounted on castor wheels. Glass wool insulation prevents heat losses. Full view inner Glass Door allows inspection of samples without disturbing temperature of chamber. Special features of Automatic BOD Incubators:

• Temperature range 5-50oC uniform cooling with cooling embedded in the walls. Temperature uniformity up to +1oC. Operating at 20oC + 1oC.

• Forced air circulation ensure uniformity of the temperature.

• Digital Temperature Cum Controller graduated in 1oC.

• Three perforated removable Aluminium or stainless steel shelves.

• Suitable to work on Volts, AC 50 Cycles, use of transformer to regulate Line advised.

Size Inside Chamber Trays D x W x H 4 Cubic Ft.(16 x 18 x 24 inch) 2

8 ANILINE POINT APPARATUS Aniline Point apparatus as per IP-2 method B ASTM D 611 by thin film method B Elec. Heated with elect. Stirrer (without thermometer)

• Spare tap

• Spare Contraction chamber

• Spare metal stirrer

1

9 ORSAT GAS ANALYZING APPARATUS complete with burrette 100ml,Levelling bottle

250ml,calcium chloride tubes fitted with rubber cork

with four absorption pipette and three test

manifold,rubber bellow fitted in wooden cabinet with

sliding doors.

Sampler for above made of glass having double bore

stopcock on both side with tubing

1

10 GAS CHROMATOGRAPHS

Highest sensitivity in its class through advanced ion optics

design for ultra trace applications

Ultra high scanning speed up to 20,000 amu/sec for Fast

and Comprehensive GC/MS

Advanced Scanning Speed Protocol (ASSP)” to ensure

highest sensitivity even at high scanning speeds

Wide Mass Range of 1.4 m/z to 1,090 m/z to meet even

wider applications

Advanced vacuum system through high capacity dual inlet

1

Page 39: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Turbo Molecular Pump with differential pumping for fast

and ultra clean vacuum

First of its kind “Twin Line MS System” coupled

with“Advanced Flow Technology”offers unique

application capabilities – Dual Column Single MS / Multi

Detector analysis.

Upgradeable with “Multi-Dimensional GC-GCMS

System” to enhance chromatographic separation capacity.

Direct compatibility to wide-bore capillary columns with

max15 ml/min carrier flow

Fast GCMS capability with micro-bore column of 0.1mm

ID for better resolution and higher throughput

Complete application utility with EI, PCI and NCI modes

Minimizes maintenance downtime with “Easy sTop” no

vent maintenance function

Compatibility to wide range of application specific

accessories

- Head Space Samplers, Auto-Samplers, Pyrolyzer, Purge

& Trap, Thermal Desorption, Olfactory Device, On-

column Derivatization etc.

Category Item No. NAME OF

EQUIPMENT specification Qty

Wavelength 185nm - 3300nm Spectral Bandwidth 8 steps in ultraviolet/visible region 0.1, 0.2,

0.5, 1, 2, 3, 5, 8 nm 10 steps in near-infrared region 0.2, 0.5, 1, 2, 3,

5, 8, 12, 20, 32 nm

Resolution 0.1 nm Sampling Pitch 0.01 - 5 nm

Wavelength accuracy UV/VIS region: ±0.2 nm NIR region: ±0. 8 nm Wavelength repeatability

UV/VIS region: less than ±0.08 nm NIR region: less than ±0.32 nm

Stray light < 0.00008% (220 nm, NaI) < 0.00005% (340 nm, NaNO2) < 0.0005% (1420 nm, H2O) < 0.005% (2365 nm, CHCl3)

Photometric range -6 to 6 Abs Noise 0.00005 Abs or less (500 nm), 0.00008 Abs or

less (900 nm), 0.00003 Abs or less (1500 nm) Slit width 2nm, RMS value at 1 sec. response

Photometric System Double beam Dimensions 1020(W) x 660(D) x 275(H) mm

Chemistry 1. UV-VIS

Spectrophotometer

SHIMADZU

Software All-in-oneSoftware UVProbe software for the UV-3600 includes functions for spectrum measurement, quantitation, kinetics and a report generator. Multiple security and audit-trail functions ensure the reliability of data.

2.

Shimadzu’s new-generation GC-2025 capillary gas chromatograph minimizes environmental impact by reducing

power and carrier gas consumption while retaining the performance capabilities required for capillary analysis.

The GC-2025 incorporates a digital flow controller that controls both the carrier and detector gases and a newly designed energy-saving column oven that features small

volume and less heating loss, realizing a dramatic

Page 40: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

GC-2025

Energy Saving

Chromatograph

improvement in operation costs. Units for Normal Analysis Crowded into a Compact

Space The compact GC-2025 is the gas chromatograph for environmentally friendly, high value performance.

The split/splitless injection unit (SPL), flame ionization

detector (FID), and electronic flow controllers (AFC/APC) are installed as standard.

Compact Design Accepts Commercial Capillary Columns Despite the compact instrument design, the small-capacity oven accommodates the shape of commercially available

capillary columns (column depth 9 cm max.).

High-Sensitivity Trace Analysis

The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.

Electronic Flow Controllers Achieve Excellent Operability and Reproducibility The GC-2025 adopts the same well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control that are used in the GC-2010 Plus. They offer highly accurate flow control to achieve excellent reproducibility.

Wave number range

7,800 to 350 cm-1

Resolution 0.5, 1, 2, 4, 8, or 16 cm-1

S/N ratio 30,000:1 or higher (peak-to-peak, 4 cm-1 resolution, in a neighborhood of 2,100 cm-1, 1-minute

accumulation)

Dimensions 514(W) X 606(D) X 273(H) mm

Weight 35Kg Equipped with Analysis Support Programs

The two main applications of infrared analysis are the analysis of contaminant and identification tests. At Shimadzu, in order to allow operators with little experience in infrared analysis to fully utilize the functionality of the IRAffinity-1, we have prepared analysis support programs. These programs are useful in a variety of analysis scenarios where infrared spectra are used.

Contaminant Analysis program

3.

IRAffinity-1 Fourier Transform

Infrared Spectrophotometer

Software

PharmaReport Program

Category ItemNo. Instruments with specification Qty

1 Digital top Loading Balances Capacity 210.00 g & accuracy of 0.0001g

1

2 Digital top Loading Balances Capacity 400.00 g & accuracy of 0.0001g

1

Basic

Science &

Humanities

3 Rotary Vacuum Evaporator with diaphragm vacuum pump ,

vacuum regulator , recirculation chiller(project) Vertical condenser with normal glass. Manual lift. Seal made of PTFE composite material, one piece vapor duct.. Speed range: 20-280 rpm , Combi clip for easy fixing and removal of vapor duct & removal of flask. Evaporation flask from 50-4000 ml. can be used without any additional adapter. Stop cock for aerating the system and rudimentary regulation of distillation process. Complete with 1 liter receiving and 1 liter evaporation flask.(STJ 29/32), operated on 220 V-240 V, 50/60 Hz. CE approval. Heating bath: Temp. range 20’C-95’C , maintenance free stainless steel pan. Display of set and actual temperature with heating on-off. Bath capacity: 4 liters. Max. Flask holding capacity : 4 liters. With integrated carrying handle. Only one power cable for rotavapour & heating bath.

1

Page 41: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Operated on 220-240 V, 50/60 Hz. CE approval. Diaphragm Pump: Chemical resistant PTFE with PEEK head. Final vacuum <10 mbar. Suction volume : 1.8 m3/hr, brushless DC motor, speed around 1600 rpm with sound absorber and integrated gas ballast , operated on 100-240 V, 50/60 Hz. CE approval. Manual vacuum control by needle valve, simple display . Woulff bottle included. Recirculating chiller :Temp. range : 10’C , flow rate : 2.5 liters /min, Pump capacity : 0.6 bar ,Tank volume : 3 litres , Cooling power : 500 W at 15’C , Refrigerant : CFC free , operated on 230 V, 50/60 Hz.

4 Flash Chromatography(binary gradient) (project)

System for binary gradient flash chromatography at a pressure up to 10 bar / 145 psi.

With a maximum pressure up to 10 bar at 250 mL/min the system offers unparalleled flexibility; suitable for any kind of application, whatever the polarity, complexity or purity of starting sample. Only one system delivers for both normal phase and reversed phase separations. Using 4 wavelengths optimized detection and collection capabilities in the UV-Vis range allows faster method development. The pump has to be a three piston one that gives the following advantages:

• A noiseless baseline • Lower pressure pulsation • Extends the life span of the columns and fittings.

System should include:

• 2 x Pump Modules: flow rate up to 250 ml/min at max. 10 bar (145 psi)

• Pump Manager with pressure sensor for precise regulation and control and mixing chamber. Calculation of time and solvent consumption facility.

• Waste level sensor. • UV-Vis detector , Dioade-array type, simultaneous scan of 4

wavelengths(measuring range 200-840 nm) • Single Injection Unit: six way valve for sample loading, for

connection of Sample Loop, Sample Chamber or Prep Elut Column.

• Sample Loop 20 ml • Set of silica Flash cartridges (4,12, 25 and 40g), loading capacity :

.005 gm – 4.0 gm. pre packed with silica, 40-63 µm.

1

Category ItemNo. Instruments with specification Qty

Forestry

1 VOC Analyser

Compound measured: Benzene, toluene, ethylbenzene- m & p-xylene, o-xylene -Ranges: 0-100, 0-200, 0-1000 mg/m2 Lower detectable limit: 0.5 mg/m3 on the 15 minute cycle; 0.25 mg/m3 on the 30 minute cycle. Sample flow rate: 0.07/mg Data storage: last 1500 average volume for each compound 8-selected independent outputs 0-20 mA/4-20 mA/0-1A/0-10V. Digital output: 2xRS232 or RS 422 Chasis: 19M rack mountable, 4U dimension: LxWxH, 581mm x 483 mm x 177 mm (22.9’ x19” x 7”) Weight 22 Kg (48 lbs) Power 115 V, 60 Hz or 230 V Option: PID or HD version Graphic liquid crystal display (LCD) Synoptic flow diagram display Remote troubleshooting diagnosis with accessories

1

Page 42: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

2 Ozone (O3) Portable Analyser Dual beam UV photometer (254 nm), Warranty 3 years, Long life mercury lamp (burnt in for 300h), 16 character alphanumeric backlit LCD, Concentration ranges: 50, 100, 200, 300, 400 g/Nm3, selectable units g/Nm3, %wt/wt and ppm, concentration error : minimum 0.5% max., Ambient temp: 0-500C, Serial interface: RS-232, bidirectional, 2400-38400 Baud, Dimension: 144Wx72Hx230mmD, O3 measurement in bench, laboratory, field, industrial ozone processes with accessories

1

3 Multi Gas Analyser

Case: High visibility, impact resistant composite-RFI, EMI and ingress protection tested and approved, Dimension4.30” x 2.45” x 1.37” (10.9cmx 6.22cmx3.48 cm), Sensors: including oxygen (O2), hydrogen (H2), hydrogen sulphide (H2S), Carbon monoxide (CO) and combustibles / hydrocarbons (LEL). Rechargable lithium ion integral battery, Runtime: 18 hour- instrument (non alarm), Large LCD, Datalogging: up to 75 hours of datalogging capability, -200C to 500C Temp range with accessories

4 Oven 252 Ltrs (605 x 455 x 910 mm) 1

5 BOD Incubator, 280 ltrs (10 Cu. Ft. 570 x 550 x 875 mm) with accessories

1

6 Waterbath Rectangular 15ltrs. (355 x 405 x 100mm) 12 holes of 75 mm dia with accessories

1

7. CHNS Analyser : Fully automated PC controlled for solid, liquid and liquid volatile samples, Sample weight range: 002 to 1000 mg, Detection range: 0 to 100% for all elements, Standard deviation: <0.1% absolute, Furnace system should have two zone furnace system, Advanced Chromatographic separation of gases , Detection system : Oxygen intrusion free thermister technology based Temperature stabilized TCD detector for measurement of CHNS. 5 years warrenty on TCD, Autosampler System, Carrier gas with Software and other accessories

1

8 Manual Rotary Microtome (Leica RM 2125 RTS) 1

9. GIS Software- Arc GIS with latest version (ESRI) 5 users

10. Furniture (Godrej) A. Lab furniture (Modulated) B. B. Class room furniture C. C. Conference Hall

Nursery and Garden equipments, Tools, Cones, root trainer

Permium cut weed cutter FBC-2 01

Permium hand lawn mower ESAY-28 01

Permium hedge shear FSH-999 03

Permium hedge shear FSH-666 03

Permium long FPLR-23 05

11.

Permium long reach pruner FPLR-21 05

Page 43: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

Permium long reach pruner FPLR-24 05

Permium extendable long reach pruner FPLR-21 05

Permium multi angular long reach pruner multipower 05

Permium folding pruning saw FS-300 05

Permium pruning saw FS-555 05

Permium fold away pruning saw with double teeth FPS-21

05

Permium grafting tool (slot cut ) FPHT-2002 02

Permium grafting tool (bud graft ) FPHT-2004 02

Permium gatherer FFG-227 05

Permium fruit catcher FFC-229 05

Permium hand digging trowel FWT-204 10

Permium hand digging trowel FWT-203 10

Permium hand weeding fork FW-102 10

Permium cultivator trowel FCH-305 10

Permium hand weeder FW-900 10

Permium onion hoe FPWH-5070 10

Permium prong cultivator FCHW-3066 10

Permium garden HOE FGWH-100 10

Permium garden Rake FRWH-16 10

Permium wire hand rake FWHR-9 10

Permium spring brace rake FSBR-48 10

Permium garden spade SPKW-25 10

Permium garden spade SPKW- 50 10

Permium garden spade SPKW-2000 10

Permium garden Shovel FSS- 4000 10

Permium garden Shovel FRS 10

Permium Khurpa SPKH 1100 10

SPKH 1200 10

SPKH 1500 10

SPKH 1800 10

Permium digger FPD-19 05

Permium bulp planter FPBP-21 05

Permium maize Sheller FPMS-1990 01

Permium home green gloves FPHG-37 10

Permium pruning saw FS-555 05

Permium hand lawn mover 01

Category ItemNo. Name of Particulars Quantity

1 Bhatia’s Battery Performance Test 1

2 Binet-Kamath’s Test of Intelligence 1

3 Seguin Form Board 1

4 Draw-A-Man Test 1

5 Denver’s Developmental Screening Test 1

Education

Dept.

6 Chatterjee’s Non-Language Preference Record 1

Page 44: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

7 Benton’s Visual Retention Test 1

8 Minnesota Multi-phasic Personality Inventory 1

9 Weschlers intelligence scale 1

10 Bender: Gestalt V- M. Test 1

11 P.P.V.Test 1

12 Indian Adaptation of Stanford Binet Test of Intelligence

by S.P.Kulshresta 1

13 Marianne Frostig Test of Visuo Motor Perception 1

14 Aston Index for Screening children with Learning

Difficulties 1

15 Behavioural cheklist to screen the L.D.(BCSLD) 1

16 Diagnostic Test of Disorder 1

17 Test of Thinking Strategies 1

18 Diagnostic Test of Learning Disabilities 1

19 Grade Level Assessment Device (GLAD) 1

20 Montessori Equipment 1

21 Computer Aided Instructions 5

22 Ear Model and Larynx Model 1

23 Case Studies of students with Learning Disability (L.D.) 5

24 Jig: Saw Puzzles, games, 5 Each

25 Sensory training material, 5

26 Art & Craft Material 5 Set

27 Stopwatch 5

28 Portable Audiometere 1

29 Diagnostic Audiometere 1

30 Speech Trainer 1

Page 45: Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) · PDF file · 2018-02-16Guru Ghasidas Vishwavidyalaya , Bilaspur (C.G.) Schedule ... carrier 02 5 BOD Incubator Maintainance free,

31 Tape Recorder 1

32 Mirror 5

33 Toy & Play Material 5 Set

34 Simple Hearing Aids 5 Each