MDE-4039 Encore™ 300 Programming Quick Reference Card Software Versions For detail on software versions see MDE-3804 Encore and Eclipse Service Manual. Power-up and Command Code 8 display the current software version. Pin Code Entry Level 1- Press F1, enter 4-digit ID (default 2222) then press ENTER. Level 2- From Level 1, enter any Level 2 Command Code (10-12), enter 4-digit ID (default 1503) then press ENTER. Level 3- From Level 2, enter any Level 3 Command Code (13-17), enter 4-digit ID (default 1309) then press ENTER. Press F1 to exit any command code. Press F2 to return to normal operation. From Level 2: Command Code 10: System Configuration Press ENTER after making selections. Enter 10. Enter Function #. Enter Configuration #. Function Code 1 (For non-blenders only: Unit Type Self configures default value. 1 = 1 product 2 = 2 product 3 = 3 product Function Code 2: Money Decimal Point 1 = xxxxx 2 = xxxx.x 3 = xxx.xx * 4 = xxx.xxx Function Code 3: Calculation PPU Decimal Point (Required in U.S. per Weights & Measures) 1 = xxxx 2 = xxx.x 3 = xx.xx 4 = x.xxx * Function Code 4: Displayed PPU Decimal Point Self configures default value. 1 = xxxx 2 = xxx.x 3 = xx.xx 4 = x.xxx Function Code 5: STP Prestart 0 = Off * 1 = On © 2001 by Marconi Commerce Systems. All Rights Reserved. * Default To calibrate meter: 1. Power up unit 2. Set Calibration switch to ‘ON’ 3. Press F1 4. Press 90 (Side 1) or 91 (Side 2) 5. Press Enter 6. Enter prover can size (5 gallons is normal and minimum recommended size for accuracy) 7. Press Enter 8. Raise handle or select grade and dispense fuel to ‘zero’ indicator on can 9. Lower Pump handle or return nozzle 10. Enter amount over or under zero (0-99 cubic inches) 11. Press ENTER twice if prover can is at zero. 12. Enter ‘0’ for readings at or above zero or ‘9’ for readings below zero 13. To calibrate other hoses/grades repeat steps beginning with Step 2. 14. If calibration is complete, set calibration switch to ‘OFF’ Error Codes Code Description 20 Pulser Fail 24 Conversion Factor Changed/ Not Programmed 25 Two-Wire/Standalone Mode Changed 26 Meter Not Calibrated 27 Side 1 Two-Wire ID Changed 28 Side 2 Two-Wire ID Changed 29 Pump Time-Out Error 30 VaporVac™ Fail Both Sides or Vapor Sense 5 31 Totals Data Error 32 Pulser Count Error 33 VaporVac Fail One Side or Push-To-Stop Button Activated 35 Configuration Data Error 36 Unit Type Configuration Code Changed 37 PIN Code 1 Changed 38 PIN Code 2 Changed 39 Cash/Credit Option Changed 40 Master Reset Jumper in Place 41 Side Exists Option Changed 44 Pump Handle Up at Power Up Blend Error Codes Code Description 4307 Blends Not Programmed 4308 No Blend Table 4311 Low Product Low Flow 4312 Hi Product Low Flow 4313 Low Product No Flow 4314 Hi Product No Flow 4315 Hi Product Contaminated by Lo 4316 Lo Product Contaminated by Hi 4329 Leaky Valve Single-Hose MPD ® Code Description 4350 Valve Control Option Not Programmed (see CC17) 4351 Valve Leaks - Grade 1 4352 Valve Leaks - Grade 2 4353 Valve Leaks - Grade 3 4355 Valve Leaks - Grade 1 & 2 4356 Valve Leaks - Grade 1 & 3 4358 Valve Leaks - Grade 2 & 3 Function code Prover can size Over or under condition (“0” or “9”) Amount over or under PPU Bar Main display Call Marconi Technical Support at: 1-800-743-7501 Marconi Commerce Systems Inc. • 7300 W. Friendly Ave., P.O. Box 22087 Greensboro, NC 27420 • Phone # 336-547-5000 • Fax # 336-292-8871 http://marconicommerce.com * Default

description

calibracion y errores comunes para encores dispensarios y guia rapida para programacion para puesta en marcha.

Transcript of Guia Rapid A - programacion calibracion

MDE-4039Encore 300 ProgrammingQuick Reference CardSoftware VersionsFor detail on software versions see MDE-3804 Encore and Eclipse Service Manual. Power-up and Command Code 8 display the current software version.Pin Code EntryLevel 1-Press F1, enter 4-digit ID (default 2222) then press ENTER.Level 2- From Level 1, enter any Level 2 Command Code (10-12), enter 4-digit ID (default 1503) then press ENTER.Level 3- From Level 2, enter any Level 3 Command Code (13-17), enter 4-digit ID (default 1309) then press ENTER.Press F1 to exit any command code.Press F2 to return to normal operation.From Level 2:Command Code 10:System ConfigurationPress ENTER after making selections. Enter 10. Enter Function #. Enter Configuration #.Function Code 1 (For non-blenders only:Unit TypeSelf configures default value.1 =1 product2 = 2 product3 = 3 productFunction Code 2: Money Decimal Point1 =xxxxx2 = xxxx.x3 = xxx.xx *4 = xxx.xxxFunction Code 3:Calculation PPU Decimal Point(Required in U.S. per Weights & Measures)1 = xxxx2 = xxx.x3 = xx.xx4 = x.xxx *Function Code 4:Displayed PPU Decimal PointSelf configures default value.1 = xxxx2 = xxx.x3 = xx.xx4 = x.xxxFunction Code 5: STP Prestart0 = Off *1 = On 2001 by Marconi Commerce Systems. All Rights Reserved.* DefaultTo calibrate meter:1.Power up unit2.Set Calibration switch to ON3.Press F14.Press 90 (Side 1) or 91 (Side 2)5.Press Enter6.Enter prover can size (5 gallons is normal and minimum recommended size for accuracy)7.Press Enter8.Raise handle or select grade and dispense fuel to zero indicator on can9. Lower Pump handle or return nozzle10. Enter amount over or under zero (0-99 cubic inches)11. Press ENTER twice if prover can is at zero.12. Enter 0 for readings at or above zero or 9 for readings below zero13. To calibrate other hoses/grades repeat steps beginning with Step 2. 14. If calibration is complete, set calibration switch to OFFError CodesCode Description 20 Pulser Fail24 Conversion Factor Changed/ Not Programmed25 Two-Wire/Standalone Mode Changed26 Meter Not Calibrated27 Side 1 Two-Wire ID Changed28 Side 2 Two-Wire ID Changed29 Pump Time-Out Error30 VaporVac Fail Both Sides or Vapor Sense 531 Totals Data Error32 Pulser Count Error33 VaporVac Fail One Side or Push-To-Stop Button Activated35 Configuration Data Error36 Unit Type Configuration Code Changed37 PIN Code 1 Changed38 PIN Code 2 Changed39 Cash/Credit Option Changed40 Master Reset Jumper in Place41 Side Exists Option Changed44 Pump Handle Up at Power UpBlend Error CodesCode Description 4307 Blends Not Programmed4308 No Blend Table4311 Low Product Low Flow4312 Hi Product Low Flow4313 Low Product No Flow4314 Hi Product No Flow4315 Hi Product Contaminated by Lo4316 Lo Product Contaminated by Hi4329 Leaky ValveSingle-Hose MPDCode Description 4350 Valve Control Option Not Programmed (see CC17)4351 Valve Leaks - Grade 14352 Valve Leaks - Grade 24353 Valve Leaks - Grade 34355 Valve Leaks - Grade 1 & 24356 Valve Leaks - Grade 1 & 34358 Valve Leaks - Grade 2 & 3Function codeProver can sizeOver or under condition (0 or 9)Amount over or underPPU BarMain displayCall Marconi Technical Support at: 1-800-743-7501Marconi Commerce Systems Inc. 7300 W. Friendly Ave., P.O. Box 22087 Greensboro, NC 27420 Phone # 336-547-5000 Fax # 336-292-8871 http://marconicommerce.com * DefaultCommand Code 12:Pump Program Enter 12 Enter Side #1 = Side 12 = Side 2 Enter Function Code (1-4) Enter Configuration CodeFunction Code 1:Two-Wire Pump ID1-16 = (7* for Side 1; 11* for Side 2)Function Code 2:Cash/Credit At Pump0 = No (CRIND) *1 = Yes (console cash/credit price levels)

Function Code 3:Side Exists0 = Does not exist1 = Exists *Function Code 4:PPU Options0 = Level 1 price bar displays level sent by console or CRIND card reader.*1 = Normal 2 = Level 2 price bar, level 1 prices and level 1/level 2 prices3 = Level 2 price bar displays level sent by console or CRINDFrom Level 3:Command Code 13:Pin Code ChangePress ENTER after selections. Enter 13 Enter Level # 1, 2 or 3 Enter new PIN CodeUnit returns to Command Input Mode.Command Code 15:Function Code 1:Preselect Time-Out0 - 999 secondsFunction Code 2:Pump Time Out0 - 999 secondsFunction Code 3:Beeper Time Out0 - 999 secondsFunction Code 4:Slowdown Valve0 - 0.999 gallonsCommand Code 16:Blend RatiosPress ENTER after making selections. Enter 16 Enter Side #1 = Side 12 = Side 23 = Both Sides Enter Grade # Enter low blend percentageRepeat for remaining gradesCommand Code 17Conversion Factor and Master ResetSelect function code.Function Code 1:Conversion Factor(ECAL switch must be ON when conversion factor is entered)0 = No conversion factor *1 = U.S. Gallons2 = Imperial Gallons3 = LitersFunction Code 2:Master Reset0 = No Master Reset1 = Master ResetMeter CalibrationRefer to MDE-3804 Service Manual for detail. Note: Before calibrating meter(s), Conversion Factor must be entered first in Command Code 17(Note: no Pin Code required)* DefaultWARNINGYou are working in a potentially dangerous environment of flammable fuels/vapors and high voltage.Fuel and its vapors may ignite, leading to serious injury or death. Fire, explosion or electrical shock could result in severe injury or death if you do not follow safe procedures. Read all safety procedures in MDE-3804 Service Manual before beginning calibration.!Function Code 16: Beeper Time-out0 = Off *1 = 5 seconds2 = 15 seconds 3 = 30 seconds4 = 45 seconds5 = 60 seconds6 = 75 seconds7 = 90 seconds8 = 120 seconds9 = 240 secondsFunction Code 17:Push to Stop Control0 = Stop controls one side *1 = Stop controls two sidesFunction Code 18:Zero Previous Transaction After Pump Handle Operation0 = Zero after lamp test *1 = Zero before lamp test 3

Function Code 19: Lamp Test1 = 1 second2 = 2 second3 = 3 second *4 = 4 second5 = 5 second6 = 6 second7 = 7 second8 = 8 second 9 = 9 secondFunction Code 20:Programmable Pump Preset Value0 = Value X 1 (enter fractions)1 = Value X 10 (enter whole units)Function Code 21:PPU Blinking Option0 = No PPU blinking*1 = PPU Blinking Function Code 22:Volume Decimal Point0 = XXX.XXX *1 = XXXX.XX (export only)Function Code 23:Program STP Control0 = Off *1 = OnFunction Code 24:Hose Pressurization0 = Off *1 = 2 Hr.2 = 1/2 Hr.*Default3Must be programmed to 1 in New Jersey.Function Code 6: Beeper Option0 = Off1 = On *Function Code 8:Two-Wire Display Blank Option:0 = Off *1 = OnFunction Code 9:5 or 6 Digit Cash Display0 = 5 Digit Money *1 = 6 Digit MoneyFunction Code 10:Decimal/Comma Mode0 = Comma Off*1 = Comma OnFunction Code 11: Preselect Time-Out 0 = None1 = 5 seconds2 = 15 seconds *3 = 30 seconds4 = 45 seconds5 = 60 seconds6 = 75 seconds7 = 90 seconds8 = 120 secondsFunction Code 12:Pump Time-Out0 = None * 1 = 5 seconds2 = 15 seconds3 = 30 seconds4 = 45 seconds5 = 60 seconds6 = 75 seconds7 = 90 seconds8 = 120 secondsFunction Code 13 (Ultra-Hi only)Slowdown0 = .070 gallons (.264 liters)1 = .120 gallons (.454 liters) *2 = .170 gallons (.643 liters)3 = .220 gallons (.833 liters)4 = .270 gallons (1.02 liters)5 = .320 gallons (1.21 liters)6 = .370 gallons (1.40 liters)7 = .420 gallons (1.59 liters)8 = .470 gallons (1.78 liters)9 = .520 gallons (1.97 liters)Function Code 14:G6 PUsh to Start0 = Off*1 = OnFunction Code 15:Zero PPU Pricing Option Enable0 = Disabled *1 = Enabled