Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following...

34
39 chainflex ® cable Jacket Shield Bending radius min., e-chain ® [factor x d] Temperature, e-chain ® from/to [°C] Approvals and standards Oil-resistant Torsion resistant v max. [m/s], unsupported v max. [m/s] gliding a max. [m/s 2 ] Page Control cables CF880 PVC 12.5 +5/ +70 3 20 42 CF881 PVC 12.5 +5/ +70 3 20 46 CF130.UL PVC 7.5 +5/ +70 3 2 20 50 CF140.UL PVC 7.5 +5/ +70 3 2 20 54 CF5 PVC 6.8 +5/ +70 10 5 80 58 CF6 PVC 6.8 +5/ +70 10 5 80 62 CF890 iguPUR 12.5 -20/ +80 3 20 66 CF891 iguPUR 12.5 -20/ +80 3 20 70 CF77.UL.D PUR 6.8 -25/ +80 10 5 80 74 CF78.UL PUR 6.8 -25/ +80 10 5 80 78 CF2 PUR 5 -20/ +80 10 5 80 82 CF9 TPE 5 -35/ +100 10 6 100 86 CF10 TPE 5 -35/ +100 10 6 100 90 CF9.UL TPE 5 -35/ +100 10 6 100 94 CF10.UL TPE 5 -35/ +100 10 6 100 98 CF98 TPE 4 -35/ +90 10 6 100 102 CF99 TPE 4 -35/ +90 10 6 100 104 New New Guarantee month guarantee 36 months chainflex ® guarantee Guaranteed lifetime for predictable reliability Selection table page 40 With the help of the chainflex ® service life calculator, you can quickly and easily calculate the expected service life of chainflex ® cables specifically for your application: www.igus.eu/chainflexlife Control cables

Transcript of Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following...

Page 1: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

39

chai

nflex

®

cabl

e

Jack

et

Shi

eld

Ben

ding

radi

us

min

., e-

chai

[fact

or x

d]

Tem

pera

ture

, e-

chai

from

/to

[°C

]

App

rova

ls a

nd

stan

dard

s

Oil-

resi

stan

t

Tors

ion

resi

stan

t

v m

ax. [

m/s

], un

supp

orte

d

v m

ax. [

m/s

] gl

idin

g

a m

ax. [

m/s

2 ]

Pag

e

Control cables

CF880 PVC 12.5 +5/ +70 3 20 42

CF881 PVC 12.5 +5/ +70 3 20 46

CF130.UL PVC 7.5 +5/ +70 3 2 20 50

CF140.UL PVC 7.5 +5/ +70 3 2 20 54

CF5 PVC 6.8 +5/ +70 10 5 80 58

CF6 PVC 6.8 +5/ +70 10 5 80 62

CF890 iguPUR 12.5 -20/ +80 3 20 66

CF891 iguPUR 12.5 -20/ +80 3 20 70

CF77.UL.D PUR 6.8 -25/ +80 10 5 80 74

CF78.UL PUR 6.8 -25/ +80 10 5 80 78

CF2 PUR 5 -20/ +80 10 5 80 82

CF9 TPE 5 -35/ +100 10 6 100 86

CF10 TPE 5 -35/ +100 10 6 100 90

CF9.UL TPE 5 -35/ +100 10 6 100 94

CF10.UL TPE 5 -35/ +100 10 6 100 98

CF98 TPE 4 -35/ +90 10 6 100 102

CF99 TPE 4 -35/ +90 10 6 100 104

New

New

Guarantee

month guarantee

36 months chainflex® guaranteeGuaranteed lifetime for predictable reliabilitySelection table page 40

With the help of the chainflex® service life calculator, you can quickly and easily calculatethe expected service life of chainflex® cables specifically for your application:

www.igus.eu/chainflexlifeCon

trol c

able

s

Page 2: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

4140

chainflex® cable

Temperature, from/to [°C]

v max. [m/s] a max. [m/s2]

Travel distance [m]

Bending radius min. [factor x d]

Bending radius min. [factor x d]

Bending radius min. [factor x d]

Page

unsupported gliding < 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

Control cables 5 million (1 million) double strokes *

7.5 million (3 million) double strokes *

10 million (5 million) double strokes *

CF880+5 / +15

3 - 20 ≤ 1015 - 16 - 17 -

42+15 / +60 12.5 - 13.5 - 14.5 -+60 / +70 15 - 16 - 17 -

CF881+5 / +15

3 - 20 ≤ 1015 - 16 - 17 -

46+15 / +60 12.5 - 13.5 - 14.5 -+70 / +70 15 - 16 - 17 -

CF130.UL+5 / +15

3 2 20 ≤ 5010 12.5 11 13.5 12 14.5

+15 / +60 7.5 10 8.5 11 9.5 12 50+60 / +70 10 12.5 11 13.5 12 14.5

CF140.UL+5 / +15

3 2 20 ≤ 5010 12.5 11 13.5 12 14.5

+15 / +60 7.5 10 8.5 11 9.5 12 54+60 / +70 10 12.5 11 13.5 12 14.5

CF5+5 / +15

10 5 80 ≤ 1007.5 10 8.5 11 9.5 12

+15 / +60 6.8 7.5 7.8 8.5 8.8 9.5 58+60 / +70 7.5 10 8.5 11 9.5 12

CF6+5 / +15

10 5 80 ≤ 1007.5 10 8.5 11 9.5 12

+15 / +60 6.8 7.5 7.8 8.5 8.8 9.5 62+60 / +70 7.5 10 8.5 11 9.5 12

CF890-20 / -10

3 - 20 ≤ 1015 - 16 - 17 -

66-10 / +70 12.5 - 13.5 - 14.5 -+70 / +80 15 - 16 - 17 -

CF891-20 / -10

3 - 20 ≤ 1015 - 16 - 17 -

70-10 / +70 12.5 - 13.5 - 14.5 -+70 / +80 15 - 16 - 17 -

CF77.UL.D-25 / -15

10 5 80 ≤ 1008.5 10 9.5 11 10.5 12

-15 / +70 6.8 7.5 7.5 8.5 8.5 9.5 74+70 / +80 7.5 10 9.5 11 10.5 12

CF78.UL-25 / -15

10 5 80 ≤ 1008.5 10 9.5 11 10.5 12

-15 / +70 6.8 7.5 7.5 8.5 8.5 9.5 78+70 / +80 7.5 10 9.5 11 10.5 12

CF2-20 / -10

10 5 80 ≤ 1006.8 7.5 8.5

-10 / +70 5 6.8 7.5 82+70 / +80 6.8 7.5 8.5

CF9-35 / -25

10 6 100 > 4006.8 7.5 8.5

-25 / +90 5 6 7 86+90 / +100 6.8 7.5 8.5

CF10-35 / -25

10 6 100 > 4006.8 7.5 8.5

-25 / +90 5 6 7 90+90 / +100 6.8 7.5 8.5

CF9.UL-35 / -25

10 6 100 > 4006.8 7.5 10

-25 / +90 5 6 7 94+90 / +100 6.8 7.5 10

CF10.UL-35 / -25

10 6 100 > 4006.8 7.5 8.5

-25 / +90 5 6 7 98+90 / +100 6.8 7.5 8.5

20 million double strokes 30 million double strokes 40 million double strokes

CF98-35 / -25

10 6 100 ≤ 1005 6 7

-25 / +80 4 5 6 102+80 / +90 5 6 7

CF99-35 / -25

10 6 100 ≤ 1005 6 7

-25 / +80 4 5 6 104+80 / +90 5 6 7

(1) Exclusive! Guaranteed lifetime for this series according to the guarantee conditions Page 22-23 * Higher number of double strokes? Online lifetime calculation www.igus.eu/chainflexlifeFigures in brackets refer to chainflex® series CF880/CF881 and CF890/CF891

New!

New!

chainflex® guarantee Guaranteed lifetime (1)

Page 3: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

4342

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF880PVC

12.5 x d

z For flexing applications zPVC outer jacket z Flame retardant

Control cable | PVC | chainflex® CF880

Dynamic informationBend radius e-chain® minimum 12.5 x d

flexible minimum 10 x dfixed minimum 7 x d

Temperature e-chain® +5 °C to +70 °Cflexible +5 °C to +70 °C (following DIN EN 60811-504)fixed -15 °C to +70 °C (following DIN EN 50305)

v max. unsupported 3 m/s

a max. 20 m/s²

Travel distance Unsupported travel distances up to 10 m, Class 1

Cable structureConductor Conductor consisting of bare copper wires (following DIN EN 60228).

Core insulation Mechanically high-quality PVC mixture.

Core structure Cores wound with an optimised pitch length.

Core identification Black cores with white numerals, one core green-yellow.

Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains®.Colour: Jet black (similar to RAL 9005)

Electrical informationNominal voltage 300/500 V

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF880

CF880PVC

12.5 x d

Properties and approvalsFlame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 11008 and 2464, 300 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01560 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00449 (Fire safety)

Lead-free Following 2011/65/EU (RoHS-II).

CE Following 2014/35/EU.

Typical mechanical application areas z For flexing applications, Class 3 z Without influence of oil, Class 1 z Preferably indoor applications z Especially for unsupported travels, Class 1 z Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment

Class 3.1.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

1 million 3 million 5 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

+5/+15 15 16 17

+15/+60 12.5 13.5 14.5

+60/+70 15 16 17

Double strokes*

Page 4: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

4544

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PVC | chainflex® CF880

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF880.05.02 2x0.5 5.5 11 38CF880.05.03 3G0.5 6.0 16 45CF880.05.04 4G0.5 6.5 22 54CF880.05.05 5G0.5 7.0 27 67CF880.05.07 7G0.5 8.5 37 99CF880.05.12 12G0.5 9.5 64 145CF880.05.18 18G0.5 11.5 96 211CF880.05.25 25G0.5 13.5 132 291CF880.07.02 2x0.75 6.0 16 47CF880.07.03 3G0.75 6.5 24 56CF880.07.04 4G0.75 7.0 32 69CF880.07.05 5G0.75 7.5 40 84CF880.07.07 7G0.75 9.0 56 125CF880.07.12 12G0.75 10.5 96 186CF880.07.18 18G0.75 13.0 143 278CF880.07.25 25G0.75 15.0 198 384CF880.10.02 2x1.0 6.5 22 54CF880.10.03 3G1.0 6.5 32 68CF880.10.04 4G1.0 7.0 43 83CF880.10.05 5G1.0 8.0 53 101CF880.10.07 7G1.0 9.5 74 153CF880.10.12 12G1.0 11.5 127 229CF880.10.18 18G1.0 13.5 191 334CF880.10.25 25G1.0 16.0 264 471CF880.15.02 2x1.5 7.5 32 83CF880.15.03 3G1.5 8.5 48 106CF880.15.04 4G1.5 9.0 64 131CF880.15.05 5G1.5 10.0 80 166CF880.15.07 7G1.5 12.5 111 250CF880.15.12 12G1.5 14.5 191 372CF880.15.18 18G1.5 17.5 286 548CF880.15.25 25G1.5 21.0 396 768CF880.25.03 3G2.5 9.0 80 147CF880.25.04 4G2.5 10.0 106 189CF880.25.05 5G2.5 11.5 132 235CF880.25.07 7G2.5 14.0 185 354CF880.25.12 12G2.5 16.5 317 533CF880.25.25 25G2.5 24.0 660 1112

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF880PVC

12.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF880

CF880PVC

12.5 x d

Order example: CF880.05.02 – to your desired length (0.5 m steps)CF880 chainflex® series .05 Code nominal cross section .02 Code Number of cores

Online order www.chainflex.eu/CF880

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 3.1.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 5: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

4746

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF881PVC

12.5 x d

z For flexing applications zPVC outer jacket z Shielded z Flame retardant

Control cable | PVC | chainflex® CF881

Dynamic informationBend radius e-chain® minimum 12.5 x d

flexible minimum 10 x dfixed minimum 7 x d

Temperature e-chain® +5 °C to +70 °Cflexible -5 °C to +70 °C (following DIN EN 60811-504)fixed -15 °C to +70 °C (following DIN EN 50305)

v max. unsupported 3 m/s

a max. 20 m/s²

Travel distance Unsupported travel distances up to 10 m, Class 1

Cable structureConductor Conductor consisting of bare copper wires (following DIN EN 60228).

Core insulation Mechanically high-quality PVC mixture.

Core structure Cores wound with an optimised pitch length.

Core identification Black cores with white numerals, one core green-yellow.

Overall shield Braiding made of tinned copper wires.Coverage approx. 60 % optical

Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains®.Colour: Jet black (similar to RAL 9005)

Electrical informationNominal voltage 300/500 V

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF881

CF881PVC

12.5 x d

Properties and approvalsFlame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 11008 and 2464, 300 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01560 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00449 (Fire safety)

Lead-free Following 2011/65/EU (RoHS-II).

CE Following 2014/35/EU.

Typical mechanical application areas z For flexing applications, Class 3 z Without influence of oil, Class 1 z Preferably indoor applications z Especially for unsupported travels, Class 1 z Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment

Class 3.1.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

1 million 3 million 5 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

+5/+15 15 16 17

+15/+60 12.5 13.5 14.5

+60/+70 15 16 17

Double strokes*

Page 6: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

4948

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PVC | chainflex® CF881

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF881.05.03 (3G0.5)C 6.5 34 60CF881.05.04 (4G0.5)C 7.0 44 75CF881.05.05 (5G0.5)C 7.5 50 86CF881.05.07 (7G0.5)C 9.0 72 123CF881.05.12 (12G0.5)C 10.5 104 172CF881.05.18 (18G0.5)C 12.0 141 238CF881.05.25 (25G0.5)C 14.5 203 338CF881.07.02 (2x0.75)C 6.5 34 60CF881.07.03 (3G0.75)C 7.0 47 76CF881.07.04 (4G0.75)C 7.5 55 88CF881.07.05 (5G0.75)C 8.0 69 111CF881.07.07 (7G0.75)C 10.0 90 150CF881.07.12 (12G0.75)C 11.5 136 215CF881.07.18 (18G0.75)C 13.5 194 306CF881.07.25 (25G0.75)C 16.0 280 433CF881.10.02 (2x1.0)C 7.0 44 73CF881.10.03 (3G1.0)C 7.5 55 85CF881.10.04 (4G1.0)C 8.0 72 107CF881.10.05 (5G1.0)C 8.5 82 126CF881.10.07 (7G1.0)C 10.5 114 177CF881.10.12 (12G1.0)C 12.0 173 256CF881.10.18 (18G1.0)C 14.5 262 386CF881.10.25 (25G1.0)C 17.0 356 524CF881.15.02 (2x1.5)C 8.5 61 104CF881.15.03 (3G1.5)C 9.0 77 125CF881.15.04 (4G1.5)C 10.0 98 159CF881.15.05 (5G1.5)C 11.0 120 192CF881.15.07 (7G1.5)C 13.0 163 270CF881.15.12 (12G1.5)C 16.0 272 425CF881.15.18 (18G1.5)C 18.5 387 608CF881.15.25 (25G1.5)C 22.0 519 814CF881.25.03 (3G2.5)C 10.0 114 171CF881.25.04 (4G2.5)C 11.0 146 221CF881.25.05 (5G2.5)C 12.0 178 262CF881.25.07 (7G2.5)C 15.0 256 384CF881.25.12 (12G2.5)C 17.5 409 585CF881.25.25 (25G2.5)C 25.0 792 1140

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF881PVC

12.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF881

CF881PVC

12.5 x d

Order example: CF881.05.03 – to your desired length (0.5 m steps)CF881 chainflex® series .05 Code nominal cross section .03 Code Number of cores

Online order www.chainflex.eu/CF881

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 3.1.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 7: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

5150

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF130.ULPVC

7.5 x d

z For medium duty applications zPVC outer jacket z Flame retardant

Control cable | PVC | chainflex® CF130.UL

Dynamic informationBend radius e-chain® minimum 7.5 x d

flexible minimum 6 x dfixed minimum 4 x d

Temperature e-chain® +5 °C to +70 °Cflexible -5 °C to +70 °C (following DIN EN 60811-504)fixed -15 °C to +70 °C (following DIN EN 50305)

v max. unsupported 3 m/sgliding 2 m/s

a max. 20 m/s²

Travel distance Unsupported travel distances and up to 50 m for gliding applications, Class 4

Torsion ± 90°, with 1 m cable length, Class 2

Cable structureConductor Finely stranded conductor consisting of bare copper wires (following DIN EN

60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores < 0.5 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.5 mm²: Black cores with white numerals, one core green-yellow.

Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains® (fol-lowing DIN EN 50363-4-1).Colour: Silver-grey (similar to RAL 7001)

CFRIP® Strip cables faster: a tear strip is moulded into the outer jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF130.UL

CF130.ULPVC

7.5 x d

Properties and approvalsFlame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 10493 and 20200, 300 V, 60 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1, material/cable tested by IPA according to ISO stand-ard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For medium duty applications z Without influence of oil z Preferably indoor applications z Unsupported travel distances and up to 50 m for gliding applications z Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment

Class 4.4.1.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

chainflex® CF130.UL for woodworking. e-chain®: E4/light

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

+5/+15 10 12.5 11 13.5 12 14.5

+15/+60 7.5 10 8.5 11 9.5 12

+60/+70 10 12.5 11 13.5 12 14.5

Double strokes*

Page 8: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

5352

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PVC | chainflex® CF130.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF130.02.03.UL 3x0.25 5.0 9 25CF130.02.04.UL 4x0.25 5.5 11 29CF130.02.06.UL 6x0.25 6.0 17 49CF130.02.07.UL 7x0.25 6.5 20 57CF130.02.12.UL 12x0.25 8.5 35 98CF130.02.20.UL 20x0.25 10.5 54 148CF130.02.25.UL 25x0.25 11.5 70 158CF130.02.30.UL 30x0.25 12.5 80 189CF130.03.02.UL 2x0.34 5.0 8 26CF130.03.05.UL 5x0.34 6.0 19 41CF130.05.02.UL 2x0.5 5.5 11 38CF130.05.03.UL 3G0.5 5.5 17 40CF130.05.04.UL 4G0.5 6.0 22 48CF130.05.05.UL 5G0.5 6.5 28 57CF130.05.07.UL 7G0.5 7.5 39 78CF130.05.12.UL 12G0.5 10.0 66 143CF130.05.18.UL 18G0.5 12.0 99 188CF130.05.25.UL 25G0.5 13.5 138 268CF130.07.02.UL 2x0.75 6.0 16 42CF130.07.03.UL 3G0.75 6.0 24 51CF130.07.04.UL 4G0.75 6.5 32 59CF130.07.05.UL 5G0.75 7.0 40 71CF130.07.07.UL 7G0.75 8.0 56 98CF130.07.12.UL 12G0.75 11.0 96 158CF130.07.18.UL 18G0.75 13.5 143 235CF130.07.25.UL 25G0.75 16.0 198 355CF130.07.36.UL 36G0.75 19.0 313 550CF130.07.42.UL 42G0.75 21.0 365 632CF130.10.02.UL 2x1.0 6.0 22 52CF130.10.03.UL 3G1.0 6.5 32 62CF130.10.04.UL 4G1.0 7.0 43 76CF130.10.05.UL 5G1.0 7.5 53 92CF130.10.07.UL 7G1.0 9.0 74 125CF130.10.12.UL 12G1.0 12.5 127 206CF130.10.18.UL 18G1.0 15.0 191 290CF130.10.25.UL 25G1.0 17.5 264 411

Strip cables 50% faster

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF130.ULPVC

7.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF130.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF130.15.02.UL 2x1.5 7.0 32 64CF130.15.03.UL 3G1.5 7.0 48 79CF130.15.04.UL 4G1.5 8.0 64 100CF130.15.05.UL 5G1.5 8.5 80 120CF130.15.07.UL 17) 7G1.5 9.5 111 160CF130.15.12.UL 12G1.5 13.0 191 287CF130.15.18.UL 18G1.5 17.5 286 484CF130.15.25.UL 25G1.5 19.5 396 617CF130.15.36.UL 36G1.5 23.5 624 932CF130.15.42.UL 11) 42G1.5 26.5 729 1084CF130.25.03.UL 3G2.5 8.5 80 123CF130.25.04.UL 4G2.5 9.5 106 153CF130.25.07.UL 17) 7G2.5 12.0 185 261CF130.25.12.UL 12G2.5 17.5 317 530CF130.40.03.UL 3G4.0 10.0 127 196CF130.40.05.UL 5G4.0 12.0 212 313CF130.60.04.UL 4G6.0 13.5 254 387CF130.60.05.UL 5G6.0 14.5 317 467CF130.160.05.UL 5G16.0 22.5 845 113511) Phase-out model17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF130.ULPVC

7.5 x d

Order example: CF130.02.03.UL – to your desired length (0.5 m steps)CF130.UL chainflex® series .02 Code nominal cross section .03 Code Number of cores

Online order www.chainflex.eu/CF130.UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 4.4.1.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 9: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

5554

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF140.ULPVC

7.5 x d

z For medium duty applications zPVC outer jacket z Shielded z Flame retardant

Control cable | PVC | chainflex® CF140.UL

Dynamic informationBend radius e-chain® minimum 7.5 x d

flexible minimum 6 x dfixed minimum 4 x d

Temperature e-chain® +5 °C to +70 °Cflexible -5 °C to +70 °C (following DIN EN 60811-504)fixed -15 °C to +70 °C (following DIN EN 50305)

v max. unsupported 3 m/sgliding 2 m/s

a max. 20 m/s2

Travel distance Unsupported travel distances and up to 50 m for gliding applications, Class 4

Cable structureConductor Finely stranded conductor consisting of bare copper wires (following DIN EN

60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores < 0.5 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.5 mm²: Black cores with white numerals, one core green-yellow.

Inner jacket PVC mixture, adapted to suit the requirements in e-chains®.

Overall shield Bending-resistant braiding made of tinned copper wires.Coverage approx. 55 % inear, approx. 80 % optical

Outer jacket Low-adhesion PVC mixture, adapted to suit the requirements in e-chains® (fol-lowing DIN EN 50363-4-1).Colour: Silver-grey (similar to RAL 7001)

CFRIP® Strip cables faster: a tear strip is moulded into the inner jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF140.UL

CF140.ULPVC

7.5 x d

Properties and approvalsFlame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 10493 and 20200, 300 V, 60 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF130.15.07.UL - tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For medium duty applications z Without influence of oil z Preferably indoor applications z Unsupported travel distances and up to 50 m for gliding applications z Wood/stone processing, Packaging industry, supply systems, Handling, adjusting equipment

Class 4.4.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

+5/+15 10 12.5 11 13.5 12 14.5

+15/+60 7.5 10 8.5 11 9.5 12

+60/+70 10 12.5 11 13.5 12 14.5

Double strokes*

Page 10: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

5756

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PVC | chainflex® CF140.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF140.02.12.UL (12x0.25)C 10.5 76 118CF140.03.05.UL (5x0.34)C 7.5 37 74CF140.05.03.UL (3G0.5)C 7.0 34 74CF140.05.05.UL (5G0.5)C 8.0 48 94CF140.05.18.UL (18G0.5)C 14.5 156 257CF140.05.36.UL (36G0.5)C 18.5 274 485CF140.07.03.UL (3G0.75)C 8.0 44 87CF140.07.04.UL (4G0.75)C 8.5 54 104CF140.07.05.UL (5G0.75)C 9.0 64 118CF140.07.07.UL (7G0.75)C 10.0 87 156CF140.07.12.UL (12G0.75)C 13.0 145 273CF140.07.18.UL (18G0.75)C 15.5 207 372CF140.07.25.UL (25G0.75)C 18.0 278 497CF140.07.36.UL 11) (36G0.75)C 22.0 416 764CF140.07.42.UL 11) (42G0.75)C 24.0 489 837CF140.10.02.UL (2x1.0)C 8.0 37 88CF140.10.03.UL (3G1.0)C 8.5 54 103CF140.10.04.UL (4G1.0)C 9.0 65 114CF140.10.05.UL (5G1.0)C 9.5 78 132CF140.10.07.UL (7G1.0)C 10.5 110 182CF140.10.12.UL (12G1.0)C 14.0 178 307CF140.10.18.UL (18G1.0)C 17.5 256 430CF140.10.25.UL (25G1.0)C 19.5 347 584CF140.15.03.UL (3G1.5)C 9.0 72 124CF140.15.04.UL (4G1.5)C 9.5 90 146CF140.15.05.UL (5G1.5)C 10.5 115 175CF140.15.07.UL 17) (7G1.5)C 12.0 153 235CF140.15.12.UL (12G1.5)C 16.0 249 403CF140.15.18.UL (18G1.5)C 19.0 368 486CF140.15.25.UL (25G1.5)C 22.5 495 768CF140.15.36.UL (36G1.5)C 26.5 715 1202CF140.15.42.UL (42G1.5)C 29.5 841 1422CF140.25.03.UL (3G2.5)C 10.5 113 208CF140.25.04.UL (4G2.5)C 11.5 148 21911) Phase-out model17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Strip cables 50% faster

CF140.ULPVC

7.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF140.UL

CF140.ULPVC

7.5 x d

Order example: CF140.02.12.UL – to your desired length (0.5 m steps)CF140.UL chainflex® series .02 Code nominal cross section .12 Code Number of cores

Online order www.chainflex.eu/CF140.UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 4.4.1.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

chainflex® CF140.UL in the feeder automation. e-chain®: easychain®

Page 11: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

5958

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF5PVC

6.8 x d

z For heavy duty applications zPVC outer jacket zOil-resistant z Flame retardant

Control cable | PVC | chainflex® CF5

Dynamic informationBend radius e-chain® minimum 6.8 x d

flexible minimum 5 x dfixed minimum 4 x d

Temperature e-chain® +5 °C to +70 °Cflexible -5 °C to +70 °C (following DIN EN 60811-504)fixed -15 °C to +70 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 5 m/s

a max. 80 m/s2

Travel distance Unsupported travel distances and up to 100 m for gliding applications, Class 5

Torsion ± 90°, with 1 m cable length, Class 2

Cable structureConductor Finely stranded conductor consisting of bare copper wires (following DIN EN

60228).Core insulation Cores ≤ 0,5 mm²: Mechanically high-quality TPE mixture.

Cores ≥ 0.75 mm²: Mechanically high-quality PVC mixture.Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.

Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores ≤ 0,34 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.5 mm²: Black cores with white numerals, one core green-yellow.

Outer jacket Low-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-4-1).Colour: Moss green (similar to RAL 6005)

CFRIP® Strip cables faster: a tear strip is moulded into the outer jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF5

CF5PVC

6.8 x d

Properties and approvalsUV resistance Medium.

Oil resistance Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Cores < 0.5 mm²: Style 10492 and 2570, 600 V, 80 °CCores ≥ 0.5 mm²: Style 11113 and 2570, 600 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 2, material/cable tested by IPA according to ISO stand-ard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heavy duty applications z Light oil influence z Preferably indoor applications, but also outdoor ones at temperatures > 5 °C z Unsupported travel distances and up to 100 m for gliding applications z Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling equipment, indoor cranes

Class 5.5.2.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

+5/+15 7.5 10 8.5 11 9.5 12

+15/+60 6.8 7.5 7.8 8.5 8.8 9.5

+60/+70 7.5 10 8.5 11 9.5 12

Double strokes*

Page 12: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

6160

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PVC | chainflex® CF5

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF5.02.36 36x0.25 15.0 105 215CF5.03.15 15x0.34 11.0 58 141CF5.03.18 18x0.34 12.0 71 182CF5.03.25 25x0.34 14.0 97 244CF5.05.02 2x0.5 6.0 11 38CF5.05.03 3G0.5 6.0 16 42CF5.05.05 5G0.5 7.0 27 75CF5.05.07 7G0.5 8.0 38 80CF5.05.12 12G0.5 11.0 64 134CF5.05.18 18G0.5 13.0 96 195CF5.05.25 25G0.5 16.0 132 289CF5.05.30 30G0.5 18.0 159 417CF5.07.03 3G0.75 6.5 24 56CF5.07.04 4G0.75 7.0 33 68CF5.07.05 5G0.75 7.5 41 84CF5.07.07 7G0.75 9.0 58 118CF5.07.12 12G0.75 12.5 96 194CF5.07.18 18G0.75 15.0 143 278CF5.07.25 25G0.75 17.5 203 397CF5.07.36 36G0.75 22.0 285 605CF5.07.42 42G0.75 24.0 333 658CF5.10.03 3G1.0 6.5 32 57CF5.10.04 4G1.0 7.0 43 80CF5.10.05 5G1.0 8.0 53 97CF5.10.07 7G1.0 9.5 78 135CF5.10.12 12G1.0 13.0 127 235CF5.10.18 18G1.0 16.5 191 318CF5.10.25 25G1.0 19.5 264 503CF5.15.03 3G1.5 7.5 48 77CF5.15.04 4G1.5 8.0 64 108CF5.15.05 5G1.5 9.0 79 132CF5.15.07 17) 7G1.5 10.5 112 187CF5.15.12 12G1.5 15.0 191 276CF5.15.18 18G1.5 19.5 285 496CF5.15.25 25G1.5 21.5 396 670

Strip cables 50% faster

17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF5PVC

6.8 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF5

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF5.15.36 36G1.5 26.5 570 1001CF5.25.04 4G2.5 10.0 102 176CF5.25.05 5G2.5 11.0 128 208CF5.25.07 17) 7G2.5 13.0 181 291CF5.25.12 12G2.5 18.5 303 499CF5.25.18 18G2.5 23.5 456 794CF5.25.25 25G2.5 27.5 637 110017) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF5PVC

6.8 x d

Order example: CF5.02.36 – to your desired length (0.5 m steps)CF5 chainflex® series .02 Code nominal cross section .36 Code Number of cores

Online order www.chainflex.eu/CF5

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 5.5.2.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

chainflex® CF5/CF6 for storage retrieval unit: Long travel in longitudinal axis. e-chain®: Series E4/00 with igus® guide trough made of steel

Page 13: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

6362

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF6PVC

6.8 x d

z For heavy duty applications zPVC outer jacket z Shielded zOil-resistant z Flame retardant

Control cable | PVC | chainflex® CF6

Dynamic informationBend radius e-chain® minimum 6.8 x d

flexible minimum 5 x dfixed minimum 4 x d

Temperature e-chain® +5 °C to +70 °Cflexible -5 °C to +70 °C (following DIN EN 60811-504)fixed -15 °C to +70 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 5 m/s

a max. 80 m/s2

Travel distance Unsupported travel distances and up to 100 m for gliding applications, Class 5

Cable structureConductor Finely stranded conductor consisting of bare copper wires (following DIN EN

60228).Core insulation Cores ≤ 0,5 mm²: Mechanically high-quality TPE mixture.

Cores ≥ 0.75 mm²: Mechanically high-quality PVC mixture.Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.

Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores ≤ 0,34 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.5 mm²: Black cores with white numerals, one core green-yellow.

Inner jacket PVC mixture, adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % inear, approx. 90 % optical

Outer jacket Low-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-4-1).Colour: Moss green (similar to RAL 6005)

CFRIP® Strip cables faster: a tear strip is moulded into the inner jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF6

CF6PVC

6.8 x d

Properties and approvalsUV resistance Medium.

Oil resistance Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Cores < 0.5 mm²: Style 10492 and 2570, 600 V, 80 °CCores ≥ 0.5 mm²: Style 11113 and 2570, 600 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heavy duty applications z Light oil influence z Preferably indoor applications, but also outdoor ones at temperatures > 5 °C z Unsupported travel distances and up to 100 m for gliding applications z Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling equipment, indoor cranes

Class 5.5.2.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

+5/+15 7.5 10 8.5 11 9.5 12

+15/+60 6.8 7.5 7.8 8.5 8.8 9.5

+60/+70 7.5 10 8.5 11 9.5 12

Double strokes*

Page 14: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

6564

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PVC | chainflex® CF6

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF6.02.04 (4x0.25)C 7.0 30 62CF6.02.25 (25x0.25)C 14.5 118 267CF6.03.05 (5x0.34)C 7.5 39 92CF6.05.02 (2x0.5)C 7.0 31 78CF6.05.05 (5G0.5)C 8.5 52 109CF6.05.07 (7G0.5)C 10.0 67 131CF6.05.09 (9G0.5)C 12.0 74 157CF6.05.12 (12G0.5)C 13.0 104 238CF6.05.18 (18G0.5)C 15.0 154 295CF6.05.25 (25G0.5)C 17.5 205 412CF6.07.03 (3G0.75)C 8.0 49 101CF6.07.04 (4G0.75)C 8.5 59 116CF6.07.05 (5G0.75)C 9.0 71 132CF6.07.07 (7G0.75)C 10.5 91 157CF6.07.12 (12G0.75)C 14.0 137 275CF6.07.18 (18G0.75)C 17.5 209 413CF6.07.25 (25G0.75)C 19.5 283 554CF6.10.03 (3G1.0)C 8.0 57 110CF6.10.04 (4G1.0)C 9.0 68 120CF6.10.05 (5G1.0)C 9.5 81 141CF6.10.07 (7G1.0)C 12.0 109 211CF6.10.12 (12G1.0)C 15.0 172 330CF6.10.18 (18G1.0)C 19.0 261 498CF6.10.25 (25G1.0)C 21.0 344 617CF6.15.03 (3G1.5)C 9.0 76 126CF6.15.04 (4G1.5)C 9.5 92 160CF6.15.05 (5G1.5)C 10.5 112 184CF6.15.07 17) (7G1.5)C 13.0 156 268CF6.15.12 (12G1.5)C 17.0 240 390CF6.15.18 (18G1.5)C 21.0 368 604CF6.15.25 (25G1.5)C 24.0 493 896CF6.15.36 (36G1.5)C 30.0 728 1346CF6.25.04 (4G2.5)C 11.5 140 23117) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Strip cables 50% faster

CF6PVC

6.8 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF6

CF6PVC

6.8 x d

Order example: CF6.02.04 – to your desired length (0.5 m steps)CF6 chainflex® series .02 Code nominal cross section .04 Code Number of cores

Online order www.chainflex.eu/CF6

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 5.5.2.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

chainflex® CF5 and CF6 control cables (green) as well as CF211 measuring system cables (grey) in a screwing station of a motor factory. e-chain®: System E4/00 with chainfix clip strain relief devices.

Page 15: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

6766

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF890iguPUR12.5 x d

z For flexing applications z iguPUR outer jacket zOil-resistant z Flame retardant

Control cable | iguPUR | chainflex® CF890

Dynamic informationBend radius e-chain® minimum 12.5 x d

flexible minimum 10 x dfixed minimum 7 x d

Temperature e-chain® -20 °C to +80 °Cflexible -40 °C to +80 °C (following DIN EN 60811-504)fixed -50 °C to +80 °C (following DIN EN 50305)

v max. unsupported 3 m/s

a max. 20 m/s²

Travel distance Unsupported travel distances up to 10 m, Class 1

Cable structureConductor Conductor consisting of bare copper wires (following DIN EN 60228).

Core insulation Mechanically high-quality PVC mixture.

Core structure Cores wound with an optimised pitch length.

Core identification Black cores with white numerals, one core green-yellow.

Outer jacket Low-adhesion iguPUR mixture, adapted to suit the requirements in e-chains®.Colour: Jet black (similar to RAL 9005)

Electrical informationNominal voltage 300/500 V

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF890

CF890iguPUR12.5 x d

Properties and approvalsUV resistance Medium.

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 11008 and 20940, 600 V, 80 °C

EAC Certificate no. RU C-DE.ME77.B.01560 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00449 (Fire safety)

Lead-free Following 2011/65/EU (RoHS-II).

CE Following 2014/35/EU.

Typical mechanical application areas z For flexing applications z With influence of oil z Indoor and outdoor applications without direct solar radiation z Especially for unsupported travels z Machining units/machine tools, low temperature applications

Class 3.1.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

1 million 3 million 5 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-20/-10 15 16 17

-10/+70 12.5 13.5 14.5

+70/+80 15 16 17

Double strokes*

Page 16: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

6968

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | iguPUR | chainflex® CF890

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF890.05.02 2x0.5 5.5 11 34CF890.05.03 3G0.5 6.0 16 42CF890.05.04 4G0.5 6.5 22 50CF890.05.05 5G0.5 7.0 27 62CF890.05.07 7G0.5 8.5 37 92CF890.05.12 12G0.5 9.5 64 136CF890.05.18 18G0.5 11.5 96 198CF890.05.25 25G0.5 13.5 132 276CF890.07.02 2x0.75 6.0 16 42CF890.07.03 3G0.75 6.5 24 52CF890.07.04 4G0.75 7.0 32 65CF890.07.05 5G0.75 7.5 40 79CF890.07.07 7G0.75 9.0 56 116CF890.07.12 12G0.75 10.5 96 176CF890.07.18 18G0.75 13.0 143 262CF890.07.25 25G0.75 15.0 198 366CF890.10.02 2x1.0 6.5 22 50CF890.10.03 3G1.0 6.5 32 63CF890.10.04 4G1.0 7.0 43 78CF890.10.05 5G1.0 8.0 53 95CF890.10.07 7G1.0 9.5 74 142CF890.10.12 12G1.0 11.5 127 217CF890.10.18 18G1.0 13.5 191 318CF890.10.25 25G1.0 16.0 264 450CF890.15.02 2x1.5 7.5 32 77CF890.15.03 3G1.5 8.5 48 99CF890.15.04 4G1.5 9.0 64 123CF890.15.05 5G1.5 10.0 80 156CF890.15.07 7G1.5 12.5 111 233CF890.15.12 12G1.5 14.5 191 352CF890.15.18 18G1.5 17.5 286 520CF890.15.25 25G1.5 21.0 396 733CF890.25.03 3G2.5 9.0 80 139CF890.25.04 4G2.5 10.0 106 178CF890.25.05 5G2.5 11.5 132 222CF890.25.07 7G2.5 14.0 185 333CF890.25.12 12G2.5 16.5 317 508CF890.25.25 25G2.5 24.0 660 1067

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF890iguPUR12.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF890

CF890iguPUR12.5 x d

Order example: CF890.05.02 – to your desired length (0.5 m steps)CF890 chainflex® series .05 Code nominal cross section .02 Code Number of cores

Online order www.chainflex.eu/CF890

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 3.1.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 17: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

7170

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF891iguPUR12.5 x d

z For flexing applications z iguPUR outer jacket zOil-resistant z Shielded z Flame retardant

Control cable | iguPUR | chainflex® CF891

Dynamic informationBend radius e-chain® minimum 12.5 x d

flexible minimum 10 x dfixed minimum 7 x d

Temperature e-chain® -20 °C to +80 °Cflexible -40 °C to +80 °C (following DIN EN 60811-504)fixed -50 °C to +80 °C (following DIN EN 50305)

v max. unsupported 3 m/s

a max. 20 m/s²

Travel distance Unsupported travel distances up to 10 m, Class 1

Cable structureConductor Conductor consisting of bare copper wires (following DIN EN 60228).

Core insulation Mechanically high-quality PVC mixture.

Core structure Cores wound with an optimised pitch length.

Core identification Black cores with white numerals, one core green-yellow.

Overall shield Braiding made of tinned copper wires.Coverage approx. 60 % optical

Outer jacket Low-adhesion iguPUR mixture, adapted to suit the requirements in e-chains®.Colour: Jet black (similar to RAL 9005)

Electrical informationNominal voltage 300/500 V

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF891

CF891iguPUR12.5 x d

Properties and approvalsUV resistance Medium.

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 11008 and 20940, 600 V, 80 °C

EAC Certificate no. RU C-DE.ME77.B.01560 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00449 (Fire safety)

Lead-free Following 2011/65/EU (RoHS-II).

CE Following 2014/35/EU.

Typical mechanical application areas z For flexing applications z With influence of oil z Indoor and outdoor applications without direct solar radiation z Especially for unsupported travels z Machining units/machine tools, low temperature applications

Class 3.1.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

1 million 3 million 5 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-20/-10 15 16 17

-10/+70 12.5 13.5 14.5

+70/+80 15 16 17

Double strokes*

Page 18: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

7372

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | iguPUR | chainflex® CF891

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF891.05.02 (2x0.5)C 6.0 28 50CF891.05.03 (3G0.5)C 6.5 34 57CF891.05.05 (5G0.5)C 7.5 50 82CF891.05.12 (12G0.5)C 10.5 104 165CF891.05.18 (18G0.5)C 12.0 141 228CF891.05.25 (25G0.5)C 14.5 203 325CF891.07.02 (2x0.75)C 6.5 34 57CF891.07.03 (3G0.75)C 7.0 47 72CF891.07.04 (4G0.75)C 7.5 55 84CF891.07.05 (5G0.75)C 8.0 69 106CF891.07.07 (7G0.75)C 10.0 90 143CF891.07.12 (12G0.75)C 11.5 136 207CF891.07.18 (18G0.75)C 13.5 194 295CF891.07.25 (25G0.75)C 16.0 280 418CF891.10.02 (2x1.0)C 7.0 44 69CF891.10.03 (3G1.0)C 7.5 55 82CF891.10.04 (4G1.0)C 8.0 72 103CF891.10.05 (5G1.0)C 8.5 82 121CF891.10.07 (7G1.0)C 10.5 114 170CF891.10.12 (12G1.0)C 12.0 173 247CF891.10.18 (18G1.0)C 14.5 262 373CF891.10.25 (25G1.0)C 17.0 356 506CF891.15.02 (2x1.5)C 8.5 61 99CF891.15.03 (3G1.5)C 9.0 77 119CF891.15.04 (4G1.5)C 10.0 98 153CF891.15.05 (5G1.5)C 11.0 120 185CF891.15.07 (7G1.5)C 13.0 163 259CF891.15.12 (12G1.5)C 16.0 272 410CF891.15.18 (18G1.5)C 18.5 387 588CF891.15.25 (25G1.5)C 22.0 519 787CF891.25.04 (4G2.5)C 11.0 146 213CF891.25.05 (5G2.5)C 12.0 178 253CF891.25.07 (7G2.5)C 15.0 256 371CF891.25.12 (12G2.5)C 17.5 409 567CF891.25.25 (25G2.5)C 25.0 792 1106

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF891iguPUR12.5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF891

CF891iguPUR12.5 x d

Order example: CF891.05.02 – to your desired length (0.5 m steps)CF891 chainflex® series .05 Code nominal cross section .02 Code Number of cores

Online order www.chainflex.eu/CF891

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 3.1.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 19: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

7574

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF77.UL.DPUR

6.8 x d

z For heavy duty applications zPUR outer jacket zOil and coolant-resistant z Flame retardant zPVC and halogen-free zNotch-resistant zHydrolysis and microbe-resistant

Control cable | PUR | chainflex® CF77.UL.D

Dynamic informationBend radius e-chain® minimum 6.8 x d

flexible minimum 5 x dfixed minimum 4 x d

Temperature e-chain® -25 °C to +80 °Cflexible -40 °C to +80 °C (following DIN EN 60811-504)fixed -50 °C to +80 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 5 m/s

a max. 80 m/s²

Travel distance Unsupported travel distances and up to 100 m for gliding applications, Class 5

Torsion ± 180°, with 1 m cable length, Class 3(except 5-core types ≥ 4,0 mm² Product range table)

Cable structureConductor Finely stranded conductor consisting of bare copper wires (following DIN EN

60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores < 0.5 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.5 mm²: Black cores with white numerals, one core green-yellow.CF77.UL.03.04.INI: brown, blue, black, white

Outer jacket Low-adhesion, highly abrasion-resistant PUR mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-10-2).Colour: Window-grey (similar to RAL 7040) CF77.UL.03.04.INI: Colour: Colza yellow (similar to RAL 1021)

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF77.UL.D

CF77.UL.DPUR

6.8 x d

Properties and approvalsUV resistance Medium.

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore MUD-resistant following NEK 606 - status 2009.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

Halogen-free Following DIN EN 60754.

UL/CSA Cores < 0.5 mm²: Style 10493 and 20233, 300 V, 80 °CCores ≥ 0.5 mm²: Style 11323 and 21223, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

DNV-GL Certified according to GL type testing – Certificate no.: 61 935-14 HH

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1, material/cable tested by IPA according to ISO stand-ard 14644-1.

DESINA According to VDW, DESINA standardisation.

CE Following 2014/35/EU.

Typical mechanical application areas z For heavy duty applications z Almost unlimited resistance to oil z Indoor and outdoor applications with average sun radiation z Unsupported travel distances and up to 100 m for gliding applications z Machining units/machine tools, Storage and retrieval units for high-bay warehouses, Packaging industry, quick handling equipment, refrigerating sector

Class 5.5.3.3

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-25/-15 8.5 10 9.5 11 10.5 12

-15/+70 6.8 7.5 7.5 8.5 8.5 9.5

+70/+80 8.5 10 9.5 11 10.5 12

Double strokes*

Page 20: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

7776

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PUR | chainflex® CF77.UL.D

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF77.UL.02.04.D 4x0.25 5.5 11 35CF77.UL.03.04.INI 4x0.34 6.0 17 40CF77.UL.05.04.D 4G0.5 6.0 22 44CF77.UL.05.05.D 5G0.5 6.5 28 52CF77.UL.05.07.D 7G0.5 7.5 41 80CF77.UL.05.12.D 12G0.5 10.0 66 132CF77.UL.05.18.D 18G0.5 12.0 99 184CF77.UL.05.25.D 25G0.5 14.0 138 247CF77.UL.05.30.D 30G0.5 15.0 165 325CF77.UL.07.03.D 3G0.75 6.5 24 55CF77.UL.07.04.D 4G0.75 7.0 32 64CF77.UL.07.05.D 5G0.75 7.5 40 75CF77.UL.07.07.D 7G0.75 8.5 56 106CF77.UL.07.12.D 12G0.75 12.0 96 192CF77.UL.07.18.D 18G0.75 13.5 143 260CF77.UL.07.20.D 20G0.75 14.5 159 292CF77.UL.07.25.D 25G0.75 16.0 198 368CF77.UL.07.36.D 36G0.75 19.0 297 524CF77.UL.07.42.D 42G0.75 21.0 365 604CF77.UL.10.02.D 2x1.0 6.5 22 54CF77.UL.10.03.D 3G1.0 6.5 32 65CF77.UL.10.04.D 4G1.0 7.0 43 79CF77.UL.10.05.D 5G1.0 8.0 53 97CF77.UL.10.07.D 7G1.0 9.0 74 119CF77.UL.10.12.D 12G1.0 12.5 127 234CF77.UL.10.18.D 18G1.0 15.0 191 339CF77.UL.10.25.D 25G1.0 17.5 264 452CF77.UL.10.42.D 42G1.0 22.5 462 708CF77.UL.15.03.D 3G1.5 7.5 48 86CF77.UL.15.04.D 4G1.5 8.0 64 105CF77.UL.15.05.D 5G1.5 8.5 80 125CF77.UL.15.07.D17) 7G1.5 10.5 111 174CF77.UL.15.12.D 12G1.5 14.0 191 308CF77.UL.15.18.D 18G1.5 17.0 286 477CF77.UL.15.25.D 25G1.5 19.5 396 630CF77.UL.15.36.D 36G1.5 23.5 594 891CF77.UL.15.42.D 42G1.5 26.5 729 1040

17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF77.UL.DPUR

6.8 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF77.UL.D

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF77.UL.25.03.D 3G2.5 8.5 80 124CF77.UL.25.04.D 4G2.5 9.5 106 155CF77.UL.25.05.D 5G2.5 10.5 132 192CF77.UL.25.07.D17) 7G2.5 12.5 185 270CF77.UL.25.12.D 12G2.5 17.5 317 530CF77.UL.40.04.D 4G4.0 11.5 176 256CF77.UL.40.05.D 5G4.0 12.0 212 302CF77.UL.60.05.D 5G6.0 14.0 317 428CF77.UL.160.05.D 11) 5G16.0 22.5 845 109811) Phase-out model17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF77.UL.DPUR

6.8 x d

Order example: CF77.UL.02.04.D – to your desired length (0.5 m steps)CF77.UL.D chainflex® series .02 Code nominal cross section .04 Code Number of cores

Online order www.chainflex.eu/CF77.UL.D

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 5.5.3.3

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 21: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

7978

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF78.ULPUR

6.8 x d

z For heavy duty applications zPUR outer jacket z Shielded zOil and coolant-resistant z Flame retardant zPVC and halogen-free zNotch-resistant zHydrolysis and microbe-resistant

Control cable | PUR | chainflex® CF78.UL

Dynamic informationBend radius e-chain® minimum 6.8 x d

flexible minimum 5 x dfixed minimum 4 x d

Temperature e-chain® -25 °C to +80 °Cflexible -40 °C to +80 °C (following DIN EN 60811-504)fixed -50 °C to +80 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 5 m/s

a max. 80 m/s2

Travel distance Unsupported travel distances and up to 100 m for gliding applications, Class 5

Cable structureConductor Finely stranded conductor consisting of bare copper wires (following DIN EN

60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Black cores with white numerals, one core green-yellow.

Inner jacket TPE mixture, adapted to suit the requirements in e-chains®.

Overall shield Bending-resistant braiding made of tinned copper wires.Coverage approx. 55 % inear, approx. 80 % optical

Outer jacket Low-adhesion, highly abrasion-resistant PUR mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-10-2).Colour: Window-grey (similar to RAL 7040)

CFRIP® Strip cables faster: a tear strip is moulded into the inner jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF78.UL

CF78.ULPUR

6.8 x d

Properties and approvalsUV resistance Medium.

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore MUD-resistant following NEK 606 - status 2009.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

Halogen-free Following DIN EN 60754.

UL/CSA Style 11323 and 21223, 1000 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

DNV-GL Certified according to GL type testing – Certificate no.: 61 935-14 HH

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF77.UL.05.12.D, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heavy duty applications z Almost unlimited resistance to oil z Indoor and outdoor applications with average sun radiation z Unsupported travel distances and up to 100 m for gliding applications z Machining units/machine tools, Storage and retrieval units for high-bay warehouses, Packaging industry, quick handling equipment, refrigerating sector

Class 5.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

< 10 m ≥ 10 m < 10 m ≥ 10 m < 10 m ≥ 10 m

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

R min. [factor x d]

-25/-15 8.5 10 9.5 11 10.5 12

-15/+70 6.8 7.5 7.5 8.5 8.5 9.5

+70/+80 8.5 10 9.5 11 10.5 12

Double strokes*

Page 22: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

8180

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PUR | chainflex® CF78.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF78.UL.05.04 (4G0.5)C 8.0 40 79CF78.UL.05.05 (5G0.5)C 8.0 48 94CF78.UL.05.07 (7G0.5)C 9.5 62 123CF78.UL.05.09 (9G0.5)C 11.0 81 148CF78.UL.05.12 (12G0.5)C 12.5 97 207CF78.UL.05.18 (18G0.5)C 14.5 156 257CF78.UL.05.25 (25G0.5)C 16.0 180 366CF78.UL.07.03 (3G0.75)C 8.0 44 79CF78.UL.07.04 (4G0.75)C 8.5 52 99CF78.UL.07.05 (5G0.75)C 9.5 64 108CF78.UL.07.07 (7G0.75)C 10.5 87 146CF78.UL.07.12 (12G0.75)C 13.5 145 252CF78.UL.07.18 (18G0.75)C 15.5 207 367CF78.UL.07.36 (36G0.75)C 22.0 416 728CF78.UL.07.42 (42G0.75)C 24.5 489 800CF78.UL.10.03 (3G1.0)C 8.5 53 90CF78.UL.10.04 (4G1.0)C 9.0 65 107CF78.UL.10.05 (5G1.0)C 9.5 78 124CF78.UL.10.07 (7G1.0)C 11.0 110 170CF78.UL.10.12 (12G1.0)C 14.5 178 307CF78.UL.10.18 (18G1.0)C 17.0 256 424CF78.UL.10.25 (25G1.0)C 20.0 347 567CF78.UL.15.03 (3G1.5)C 9.5 72 133CF78.UL.15.04 (4G1.5)C 10.0 90 139CF78.UL.15.05 (5G1.5)C 10.5 115 166CF78.UL.15.07 17) (7G1.5)C 12.5 153 226CF78.UL.15.12 (12G1.5)C 16.0 249 403CF78.UL.15.18 (18G1.5)C 19.0 368 564CF78.UL.15.25 (25G1.5)C 22.5 495 755CF78.UL.15.36 (36G1.5)C 26.5 715 1147CF78.UL.15.42 (42G1.5)C 29.5 884 1360CF78.UL.25.04 (4G2.5)C 11.5 148 212CF78.UL.25.05 (5G2.5)C 12.5 177 247CF78.UL.25.07 17) (7G2.5)C 14.5 245 350CF78.UL.25.12 (12G2.5)C 19.0 407 610CF78.UL.40.04 (4G4.0)C 14.0 217 34217) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Strip cables 50% faster

CF78.ULPUR

6.8 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF78.UL

CF78.ULPUR

6.8 x d

Order example: CF78.UL.05.04 – to your desired length (0.5 m steps)CF78.UL chainflex® series .05 Code nominal cross section .04 Code Number of cores

Online order www.chainflex.eu/CF78.UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 5.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Page 23: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

8382

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF2PUR5 x d

z For extremely heavy duty applications zPUR outer jacket z Shielded zOil and coolant-resistant z Flame retardant zNotch-resistant zHydrolysis and microbe-resistant

Control cable | PUR | chainflex® CF2

Dynamic informationBend radius e-chain® minimum 5 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -20 °C to +80 °Cflexible -40 °C to +80 °C (following DIN EN 60811-504)fixed -50 °C to +80 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 5 m/s

a max. 80 m/s2

Travel distance Unsupported travel distances and up to 100 m for gliding applications, Class 5

Cable structureConductor Stranded conductor in especially bending-resistant design consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Colour code in accordance with DIN 47100.

Inner jacket PVC mixture, adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % inear, approx. 90 % optical

Outer jacket Low-adhesion, highly abrasion-resistant PUR mixture, adapted to suit the requirements in e-chains® (following DIN EN 50363-10-2).Colour: Anthracite grey (similar to RAL 7016)

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF2

CF2PUR5 x d

Properties and approvalsUV resistance High.

Oil resistance Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore MUD-resistant following NEK 606 - status 2009.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Style 10493 and 20317, 300 V, 80 °C

NFPA Following NFPA 79-2012 chapter 12.9.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications z Almost unlimited resistance to oil z Indoor and outdoor applications z Unsupported travel distances and up to 100 m for gliding applications z Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling equipment, indoor cranes, refrigerating sector

Class 6.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-20/-10 6.8 7.5 8.5

-10/+70 5 6.8 7.5

+70/+80 6.8 7.5 8.5

Double strokes*

Page 24: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

8584

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | PUR | chainflex® CF2

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF2.01.04 (4x0.14)C 6.5 17 40CF2.01.08 (8x0.14)C 7.5 29 65CF2.01.12 (12x0.14)C 9.5 49 101CF2.01.18 (18x0.14)C 10.5 53 125CF2.01.24 3) (24x0.14)C 11.5 65 135CF2.01.36 (36x0.14)C 14.5 88 200CF2.01.48 (48x0.14)C 16.5 135 310CF2.02.04 (4x0.25)C 7.0 24 53CF2.02.08 (8x0.25)C 8.5 41 83CF2.02.18 (18x0.25)C 12.5 96 190CF2.02.24 3) (24x0.25)C 13.5 120 220CF2.02.48 (48x0.25)C 18.0 230 450The chainflex® types marked with a 3) refer to cables that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quad with especially low crosstalk), these cables can be used in virtually all cases in which twisted-pair cables are normally required.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF2PUR5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF2

CF2PUR5 x d

Order example: CF2.01.04 – to your desired length (0.5 m steps)CF2 chainflex® series .01 Code nominal cross section .04 Code Number of cores

Online order www.chainflex.eu/CF2

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 6.5.3.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

chainflex® CF2 cables are resistant to oil and coolants. e-chain®: System E4/00

Page 25: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

8786

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF9TPE5 x d

z For heaviest duty applications z TPE outer jacket zOil-resistant, bio-oil-resistant zPVC and halogen-free z Low-temperature-flexible zHydrolysis and microbe-resistant

Control cable | TPE | chainflex® CF9

Dynamic informationBend radius e-chain® minimum 5 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -35 °C to +100 °Cflexible -50 °C to +100 °C (following DIN EN 60811-504)fixed -55 °C to +100 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Torsion ± 90°, with 1 m cable length, Class 2

Cable structureConductor Stranded conductor in especially bending-resistant design consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores < 0.75 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.75 mm²: Black cores with white numerals, one core green-yellow.CF9.02.03.INI: brown, blue, blackCF9.03.04.INI: brown, blue, black, whiteCF9.03.05.INI: brown blue, black, white, green-yellowCF9.03.16.07.03.INI:0.34 mm²: violet/red/grey/red-blue, green/grey-pink/white-green/white-yellow,white-grey/black/yellow-brown/brown-green, white/yellow/pink/grey-brown0.75 mm²: blue/green-yellow/brown

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

CFRIP® Strip cables faster: a tear strip is moulded into the outer jacketVideo www.igus.eu/CFRIP

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF9

CF9TPE5 x d

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Properties and approvalsUV resistance High.

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

Halogen-free Following DIN EN 60754.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1, material/cable tested by IPA according to ISO stand-ard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications z Almost unlimited resistance to oil, also with bio-oils z Indoor and outdoor applications, UV resistant z Unsupported travel distances and up to 400 m and more for gliding applications z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling equipment, Clean room, semiconductor handling, outdoor cranes, low temperature applications

Class 7.6.4.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

chainflex® CF9 for outdoor crane systems. e-chain®: Series E4/00

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 6.8 7.5 8.5

-25/+90 5 6 7

+90/+100 6.8 7.5 8.5

Double strokes*

New!

Page 26: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

8988

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | TPE | chainflex® CF9

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF9.02.02 2x0.25 4.5 6 18CF9.02.03.INI 3x0.25 4.5 8 22CF9.02.06 6x0.25 5.5 16 37CF9.02.07 7x0.25 6.5 19 44CF9.02.08 8x0.25 6.5 22 50CF9.02.12 12x0.25 8.0 32 73CF9.02.18 18x0.25 9.5 48 105CF9.02.20 20x0.25 9.5 53 111

New CF9.02.25 25x0.25 11.0 66 144CF9.03.04.INI 4x0.34 5.0 15 32CF9.03.05.INI 5x0.34 5.5 18 38CF9.03.06 6x0.34 6.0 22 45CF9.03.08 8x0.34 7.0 29 59CF9.03.16.07.03.INI 4x(4x0.34)+(3x0.75) 11.0 82 159CF9.05.02 2x0.5 5.0 11 26CF9.05.03 3x0.5 5.0 16 32CF9.05.04 4x0.5 5.5 22 40CF9.05.05 5x0.5 6.0 27 48CF9.05.07 7x0.5 7.0 37 66CF9.05.12 12x0.5 10.0 64 120CF9.05.18 18x0.5 11.5 96 177CF9.05.25 25x0.5 13.0 132 236CF9.05.36 36x0.5 15.5 191 334CF9.07.04 4G0.75 6.0 32 55CF9.07.05 5G0.75 6.5 40 68CF9.07.07 7G0.75 8.0 56 94CF9.07.12 12G0.75 11.0 96 170CF9.07.20 20G0.75 13.5 159 267CF9.07.25 25G0.75 14.5 198 329CF9.10.03 3G1.0 6.0 32 54CF9.10.04 4G1.0 6.5 43 69CF9.10.05 5G1.0 7.5 53 84CF9.10.12 12G1.0 12.0 127 214CF9.10.18 18G1.0 14.5 191 314CF9.10.25 25G1.0 17.0 264 450

Strip cables 50% faster

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF9TPE5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF9

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF9.15.02 2x1.5 6.5 32 60CF9.15.04 4G1.5 7.5 64 90CF9.15.05 5G1.5 8.0 81 110CF9.15.07 17) 7G1.5 9.5 114 151CF9.15.12 12G1.5 13.5 191 290CF9.15.18 18G1.5 16.5 286 413CF9.15.25 25G1.5 20.0 396 632CF9.15.36 36G1.5 23.5 571 839CF9.25.04 4G2.5 9.0 106 152CF9.25.05 5G2.5 10.0 132 197CF9.25.07 17) 7G2.5 12.0 187 245CF9.25.12 12G2.5 17.5 317 515CF9.25.16 16G2.5 19.5 423 687CF9.25.18 7) 18G2.5 23.0 476 830CF9.25.25 25G2.5 24.5 660 1059CF9.40.04 4G4.0 10.5 170 229CF9.60.04 4G6.0 12.5 254 332CF9.60.05 5G6.0 13.5 317 410CF9.100.04 4G10.0 16.5 423 580CF9.160.04 4G16.0 18.0 528 719CF9.350.04 11) 4G35.0 28.0 1479 17697) Nominal voltage 600/1000 V 11) Phase-out model17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF9TPE5 x dClass 7.6.4.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

für höchste Dynamik und kleine Radien in einer Anlage zur Herstellungen von Medizinprodukten

New!

Page 27: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

9190

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF10TPE5 x d

z For heaviest duty applications z TPE outer jacket z Shielded zOil-resistant, bio-oil-resistant zPVC and halogen-free z Low-temperature-flexible zHydrolysis and microbe-resistant

Control cable | TPE | chainflex® CF10

Dynamic informationBend radius e-chain® minimum 5 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -35 °C to +100 °Cflexible -50 °C to +100 °C (following DIN EN 60811-504)fixed -55 °C to +100 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Cable structureConductor Stranded conductor in especially bending-resistant design consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores < 0.75 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.75 mm²: Black cores with white numerals, one core green-yellow.CF10.03.05.INI: brown blue, black, white, green-yellow

Inner jacket TPE mixture, adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % inear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

CFRIP® Strip cables faster: a tear strip is moulded into the inner jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF10

CF10TPE5 x d

Properties and approvalsUV resistance High.

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

Halogen-free Following DIN EN 60754.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications z Almost unlimited resistance to oil, also with bio-oils z Indoor and outdoor applications, UV resistant z Unsupported travel distances and up to 400 m and more for gliding applications z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling equipment, Clean room, semiconductor handling, outdoor cranes, low temperature applications

Class 7.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 6.8 7.5 8.5

-25/+90 5 6 7

+90/+100 6.8 7.5 8.5

Double strokes*

Page 28: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

9392

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | TPE | chainflex® CF10

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF10.01.12 (12x0.14)C 8.0 40 82CF10.01.18 (18x0.14)C 9.5 68 127CF10.02.04 (4x0.25)C 6.5 26 52CF10.02.08 (8x0.25)C 8.0 42 81CF10.02.12 (12x0.25)C 9.5 70 127CF10.02.25 (25x0.25)C 12.5 119 225CF10.03.05.INI (5x0.34)C 7.0 36 65CF10.05.04 (4x0.5)C 7.0 39 69CF10.05.05 (5x0.5)C 7.5 46 79CF10.05.07 (7x0.5)C 8.5 60 103CF10.05.12 (12x0.5)C 12.0 113 199CF10.05.18 (18x0.5)C 13.5 153 263CF10.05.25 (25x0.5)C 15.0 198 335CF10.07.04 (4G0.75)C 7.5 51 87CF10.07.05 (5G0.75)C 8.0 61 99CF10.07.07 (7G0.75)C 9.5 94 145CF10.07.12 (12G0.75)C 12.5 146 246CF10.07.20 (20G0.75)C 15.0 226 368CF10.07.25 (25G0.75)C 16.5 270 450CF10.10.02 (2x1.0)C 7.5 39 72CF10.10.03 (3G1.0)C 7.5 51 83CF10.10.04 (4G1.0)C 8.0 64 103CF10.10.05 (5G1.0)C 8.5 74 120CF10.10.07 (7G1.0)C 10.0 116 179CF10.10.12 (12G1.0)C 13.5 186 302CF10.10.18 (18G1.0)C 16.0 262 415CF10.10.25 (25G1.0)C 18.0 344 550CF10.15.04 (4G1.5)C 9.0 99 145CF10.15.05 (5G1.5)C 10.0 119 176CF10.15.07 17) (7G1.5)C 11.5 159 235CF10.15.12 (12G1.5)C 15.5 259 391CF10.15.18 (18G1.5)C 20.0 398 624CF10.25.04 (4G2.5)C 11.0 149 224CF10.25.07 17) (7G2.5)C 13.5 244 364CF10.25.12 (12G2.5)C 19.0 411 653CF10.40.04 (4G4.0)C 12.5 222 317CF10.40.05 (5G4.0)C 13.5 271 38617) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Strip cables 50% faster

CF10TPE5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF10

CF10TPE5 x d

Order example: CF10.01.12 – to your desired length (0.5 m steps)CF10 chainflex® series .01 Code nominal cross section .12 Code Number of cores

Online order www.chainflex.eu/CF10

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 7.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Control cable chainflex® CF10 in storage and retrieval units for high-bay warehouses. e-chain®: System E2

Page 29: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

9594

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF9.ULTPE5 x d

z For extremely heavy duty applications z TPE outer jacket zOil-resistant, bio-oil-resistant z Flame retardant zPVC-free z Low-temperature-flexible zHydrolysis and microbe-resistant

Control cable | TPE | chainflex® CF9.UL

Dynamic informationBend radius e-chain® minimum 5 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -35 °C to +100 °Cflexible -45 °C to +100 °C (following DIN EN 60811-504)fixed -50 °C to +100 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Torsion ± 90°, with 1 m cable length, Class 2

Cable structureConductor Stranded conductor in especially bending-resistant design consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores < 0.75 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.75 mm²: Black cores with white numerals, one core green-yellow.CF9.UL.02.03.INI: brown, blue, blackCF9.UL.03.04.INI: brown, blue, black, whiteCF9.UL.03.05.INI: brown blue, black, white, green-yellow

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Slate grey (similar to RAL 7015)

CFRIP® Strip cables faster: a tear strip is moulded into the outer jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF9.UL

CF9.ULTPE5 x d

Properties and approvalsUV resistance High.

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Cores < 0.5 mm²: Style 10479 and 21529, 300 V, 90 °CCores ≥ 0.5 mm²: Style 10258 and 21387, 1000 V, 90 °C

NFPA Following NFPA 79-2012 chapter 12.9.

DNV-GL Certified according to GL type testing – Certificate no.: 61 935-14 HH

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications z Almost unlimited resistance to oil, also with bio-oils z Indoor and outdoor applications, UV resistant z Unsupported travel distances and up to 400 m and more for gliding applications z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling equipment, Clean room, semiconductor handling, outdoor cranes, low temperature applications

Class 6.6.4.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 6.8 7.5 8.5

-25/+90 5 6 7

+90/+100 6.8 7.5 8.5

Double strokes*

Page 30: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

9796

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | TPE | chainflex® CF9.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF9.UL.02.02 2x0.25 5.0 6 28CF9.UL.02.03.INI 3x0.25 5.5 8 32CF9.UL.02.04 4x0.25 5.5 11 38CF9.UL.02.06 6x0.25 6.5 16 49CF9.UL.02.08 8x0.25 7.5 22 64CF9.UL.02.12 12x0.25 8.5 32 94CF9.UL.03.04.INI 4x0.34 6.0 15 43CF9.UL.03.05.INI 5x0.34 6.5 18 53CF9.UL.03.06 6x0.34 6.5 22 57CF9.UL.03.08 8x0.34 7.5 29 76CF9.UL.05.02 2x0.5 6.0 11 43CF9.UL.05.03 3x0.5 6.5 16 52CF9.UL.05.04 4x0.5 7.0 22 60CF9.UL.05.05 5x0.5 7.5 27 70CF9.UL.05.07 7x0.5 8.5 37 96CF9.UL.05.12 12x0.5 11.5 64 170CF9.UL.05.18 18x0.5 13.5 96 239CF9.UL.05.25 25x0.5 14.5 132 296CF9.UL.05.36 11) 36x0.5 18.5 191 460CF9.UL.07.05 5G0.75 8.0 40 96CF9.UL.07.07 7G0.75 9.5 56 133CF9.UL.07.12 12G0.75 13.0 96 234CF9.UL.07.25 25G0.75 16.5 198 421CF9.UL.10.03 3G1.0 7.5 32 78CF9.UL.10.04 4G1.0 8.0 43 97CF9.UL.10.12 12G1.0 14.0 127 283CF9.UL.10.18 18G1.0 16.5 191 406CF9.UL.10.25 25G1.0 18.5 264 541CF9.UL.15.04 4G1.5 9.0 64 126CF9.UL.15.05 5G1.5 9.5 80 150CF9.UL.15.07 17) 7G1.5 11.5 111 206CF9.UL.15.12 12G1.5 16.0 191 384CF9.UL.15.18 18G1.5 19.0 286 553CF9.UL.15.25 25G1.5 22.0 396 756CF9.UL.25.04 4G2.5 10.5 106 194CF9.UL.25.05 5G2.5 11.0 132 239

Strip cables 50% faster

11) Phase-out model17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF9.ULTPE5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF9.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF9.UL.25.07 17) 7G2.5 13.5 185 328CF9.UL.25.12 12G2.5 19.0 317 620CF9.UL.25.18 18G2.5 24.0 476 917CF9.UL.25.25 25G2.5 27.0 660 1199CF9.UL.40.04 4G4.0 12.0 169 271CF9.UL.60.04 4G6.0 14.0 254 38017) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

CF9.ULTPE5 x d

Order example: CF9.UL.02.02 – to your desired length (0.5 m steps)CF9.UL chainflex® series .02 Code nominal cross section .02 Code Number of cores

Online order www.chainflex.eu/CF9.UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 6.6.4.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

igus® chainflex® cables in a lift application of a rafting channel.

Page 31: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

9998

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF10.ULTPE5 x d

z For extremely heavy duty applications z TPE outer jacket z Shielded zOil-resistant, bio-oil-resistant z Flame retardant zPVC-free z Low-temperature-flexible zHydrolysis and microbe-resistant

Control cable | TPE | chainflex® CF10.UL

Dynamic informationBend radius e-chain® minimum 5 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -35 °C to +100 °Cflexible -45 °C to +100 °C (following DIN EN 60811-504)fixed -50 °C to +100 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Unsupported travel distances and up to 400 m and more for gliding applica-tions, Class 6

Cable structureConductor Stranded conductor in especially bending-resistant design consisting of bare

copper wires (following DIN EN 60228).Core insulation Mechanically high-quality TPE mixture.

Core structure Number of cores < 12: Cores wound in a layer with a short pitch length.Number of cores ≥ 12: Cores wound in bundles which are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions.

Core identification Cores ≥ 0.75 mm²: Colour code in accordance with DIN 47100.Cores ≥ 0.75 mm²: Black cores with white numerals, one core green-yellow.

Inner jacket TPE mixture, adapted to suit the requirements in e-chains®.

Overall shield Extremely bending-resistant braiding made of tinned copper wires.Coverage approx. 70 % inear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Slate grey (similar to RAL 7015)

CFRIP® Strip cables faster: a tear strip is moulded into the inner jacketVideo www.igus.eu/CFRIP

Electrical informationNominal voltage 300/500 V (following DIN VDE 0298-3)

Testing voltage 2000 V (following DIN EN 50395)

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF10.UL

CF10.ULTPE5 x d

Properties and approvalsUV resistance High.

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Flame retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

UL/CSA Cores < 0.5 mm²: Style 10479 and 21529, 300 V, 90 °CCores ≥ 0.5 mm²: Style 10258 and 21387, 1000 V, 90 °C

NFPA Following NFPA 79-2012 chapter 12.9.

DNV-GL Certified according to GL type testing – Certificate no.: 61 935-14 HH

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

CTP Certificate no. C-DE.PB49.B.00416 (Fire safety)

CEI Following CEI 20-35.

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF34.UL.25.04.D, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications z Almost unlimited resistance to oil, also with bio-oils z Indoor and outdoor applications, UV resistant z Unsupported travel distances and up to 400 m and more for gliding applications z Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling equipment, Clean room, semiconductor handling, outdoor cranes, low temperature applications

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

5 million 7.5 million 10 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 6.8 7.5 8.5

-25/+90 5 6 7

+90/+100 6.8 7.5 8.5

Double strokes*

New!

Page 32: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

101100

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

Example image

Control cable | TPE | chainflex® CF10.UL

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF10.UL.02.04 (4x0.25)C 7.0 28 69CF10.UL.02.08 (8x0.25)C 9.0 41 104CF10.UL.02.12 (12x0.25)C 10.5 70 158

New CF10.UL.02.25 (25x0.25)C 13.0 119 259CF10.UL.05.04 (4x0.5)C 8.5 41 99CF10.UL.05.05 (5x0.5)C 9.0 48 112CF10.UL.05.12 (12x0.5)C 13.0 117 259CF10.UL.05.18 11) (18x0.5)C 15.0 161 349CF10.UL.05.25 (25x0.5)C 16.5 204 420CF10.UL.07.03 (3G0.75)C 8.5 44 106CF10.UL.07.04 (4G0.75)C 9.0 54 123CF10.UL.07.05 (5G0.75)C 10.0 75 156CF10.UL.07.07 (7G0.75)C 11.0 99 203CF10.UL.07.12 (12G0.75)C 14.5 158 342CF10.UL.07.20 (20G0.75)C 17.0 235 482CF10.UL.07.25 (25G0.75)C 19.0 307 618CF10.UL.10.02 (2x1.0)C 8.5 42 105CF10.UL.10.03 (3G1.0)C 9.0 53 121CF10.UL.10.04 (4G1.0)C 10.0 79 158CF10.UL.10.05 (5G1.0)C 10.5 92 181CF10.UL.10.07 (7G1.0)C 12.0 120 238CF10.UL.10.12 11) (12G1.0)C 15.0 189 380CF10.UL.10.18 (18G1.0)C 19.0 302 586CF10.UL.10.25 (25G1.0)C 21.5 390 772CF10.UL.15.04 (4G1.5)C 10.5 104 194CF10.UL.15.05 (5G1.5)C 11.5 124 228CF10.UL.15.07 17) (7G1.5)C 13.0 164 299CF10.UL.15.12 (12G1.5)C 18.0 268 523CF10.UL.15.18 (18G1.5)C 21.5 413 771CF10.UL.25.04 (4G2.5)C 12.0 154 276CF10.UL.25.07 17) (7G2.5)C 15.0 250 441CF10.UL.25.12 (12G2.5)C 21.5 445 845CF10.UL.40.04 (4G4.0)C 13.5 227 37611) Phase-out model17) When using the cables with „7 G 1.5 mm²“ and „7 G 2.5 mm²“ minimum bend radius must be 17.5 x d with gliding travel distance ≥ 5 m.Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Strip cables 50% faster

CF10.ULTPE5 x d

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF10.UL

CF10.ULTPE5 x d

Order example: CF10.UL.02.04 – to your desired length (0.5 m steps)CF10.UL chainflex® series .02 Code nominal cross section .04 Code Number of cores

Online order www.chainflex.eu/CF10.UL

Delivery time 24h or today.Delivery time means time until shipping of goods.

Class 6.6.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

The special cable structure of chainflex® CF10.UL guarantees quality – offered by igus® fully harnessed.

New!

Braided in bundles

Tensile stress resistant centre element

Gusset-filling extruded inner jacket

Overall shield with optimised braiding angle

Pressure extruded outer jacket

Page 33: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

103102

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF98TPE4 x d

z For heaviest duty applications and especially small radii up to 4 x d z TPE outer jacket zOil-resistant, bio-oil-resistant zPVC and halogen-free z Low-temperature-flexible zHydrolysis and microbe-resistant

Control cable | TPE | chainflex® CF98

Dynamic informationBend radius e-chain® minimum 4 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -35 °C to +90 °Cflexible -50 °C to +90 °C (following DIN EN 60811-504)fixed -55 °C to +90 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Short, very fast applications with small radii and tight design space, Class 5

Torsion ± 90°, with 1 m cable length, Class 2

Cable structureConductor Conductor consisting of a special highly flexible alloy.

Core insulation Mechanically high-quality TPE mixture.

Core structure Cores wound in a layer with a short pitch length.

Core identification Colour code in accordance with DIN 47100.CF98.02.03.INI: brown, blue, blackCF98.03.04.INI: brown, blue, black, white

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

Electrical informationNominal voltage 300/300 V

Testing voltage 1500 V

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF98

CF98TPE4 x d

Properties and approvalsUV resistance High.

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

Halogen-free Following DIN EN 60754.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications and especially small radii up to 4 x d z Almost unlimited resistance to oil, also with bio-oils z Indoor and outdoor applications, UV resistant z Especially for short, very fast applications with small radii and tight design space z Pick and place machines, automatic doors, Clean room, very quick handling equipment

Class 7.5.4.2

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

20 million 30 million 40 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 5 6 7

-25/+80 4 5 6

+80/+90 5 6 7

Double strokes*

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF98.01.02 2x0.14 4.0 4 11CF98.01.03 11) 3x0.14 4.5 6 14CF98.01.04 4x0.14 5.0 9 16CF98.01.08 8x0.14 6.5 16 24CF98.02.03.INI 3x0.25 5.0 12 25CF98.02.04 4x0.25 5.5 16 30CF98.02.07 7x0.25 6.5 26 53CF98.02.08 8x0.25 7.0 30 60CF98.03.04.INI 4x0.34 5.5 19 35CF98.03.07 11) 7x0.34 7.0 32 55CF98.05.04 4x0.5 6.0 31 40

11) Phase-out modelNote: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Page 34: Guarantee - Igus€¦ · CTP Certificate no. C-DE.PB49.B.00449 (Fire safety) Lead-free Following 2011/65/EU (RoHS-II). CE Following 2014/35/EU. Typical mechanical application areas

105104

Guarantee

month guarantee

36 months guarantee ... 1,354 types from stock ... no cutting charges

CF99TPE4 x d

z For heaviest duty applications and especially small radii up to 4 x d z TPE outer jacket z Shielded zOil-resistant, bio-oil-resistant zPVC and halogen-free z Low-temperature-flexible zHydrolysis and microbe-resistant

Control cable | TPE | chainflex® CF99

Dynamic informationBend radius e-chain® minimum 4 x d

flexible minimum 4 x dfixed minimum 3 x d

Temperature e-chain® -35 °C to +90 °Cflexible -50 °C to +90 °C (following DIN EN 60811-504)fixed -55 °C to +90 °C (following DIN EN 50305)

v max. unsupported 10 m/sgliding 6 m/s

a max. 100 m/s2

Travel distance Short, very fast applications with small radii and tight design space, Class 5

Cable structureConductor Conductor consisting of a special highly flexible alloy.

Core insulation Mechanically high-quality TPE mixture.

Core structure Cores wound in a layer with a short pitch length.

Core identification Colour code in accordance with DIN 47100.CF99.02.03.INI: brown, blue, blackCF99.03.04.INI: brown, blue, black, white

Inner jacket TPE mixture, adapted to suit the requirements in e-chains®.

Overall shield Extremely bending resistant, special alloy shield.Coverage approx. 70 % inear, approx. 90 % optical

Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)

Electrical informationNominal voltage 300/300 V

Testing voltage 1500 V

Exa

mpl

e im

age

PVC iguPUR PUR TPE

EPLAN download, configurators www.igus.eu/CF99

CF99TPE4 x d

Properties and approvalsUV resistance High.

Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992).

Halogen-free Following DIN EN 60754.

EAC Certificate no. RU C-DE.ME77.B.01254 (TR ZU)

Lead-free Following 2011/65/EU (RoHS-II).

Cleanroom According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1.

CE Following 2014/35/EU.

Typical mechanical application areas z For heaviest duty applications and especially small radii up to 4 x d z Almost unlimited resistance to oil, also with bio-oils z Indoor and outdoor applications, UV resistant z Especially for short, very fast applications with small radii and tight design space z Pick and place machines, automatic doors, Clean room, very quick handling equipment

Class 7.5.4.1

Basic requirements low 1 2 3 4 5 6 7 highest

Travel distance unsupported 1 2 3 4 5 6 ≥ 400 m

Oil resistance none 1 2 3 4 highest

Torsion none 1 2 3 ±180°

Guaranteed lifetime according to guarantee conditions (Page 22-23)

* Higher number of double strokes? Online lifetime calculation: www.igus.eu/chainflexlife

20 million 30 million 40 million

Temperature,from/to [°C]

R min. [factor x d] R min. [factor x d] R min. [factor x d]

-35/-25 5 6 7

-25/+80 4 5 6

+80/+90 5 6 7

Double strokes*

Part No. Number of cores and conductor nominal cross section

Outer diameter (d) max.

Copper index

Weight

[mm²] mm kg/km kg/kmCF99.01.02 (2x0.14)C 5.5 14 33CF99.01.04 (4x0.14)C 6.0 21 43CF99.01.08 (8x0.14)C 8.0 36 69CF99.02.04 (4x0.25)C 6.5 30 56CF99.02.07 (7x0.25)C 8.0 48 85CF99.03.08 (8x0.34)C 9.0 64 105

Note: The given outer diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core