INTRODUCTION
Fire protection systems are essential to protect human lives and material goods in case of fire.
A yearly maintenance required by law as well as repair measures ensure durable availibility and protection in an emergency.
The gte Service team is specialized in fire prevention of conveyors and ensures withits services for maximum safety at airports, manufactories and logistic centers.
We have more than 15 years of experience in our business, a great number of well-known companies as our customers and we maintain projects all over the world.
SERVICE PORTFOLIO
3
maintenancespare parts
servicetraining
gte Schoolreplacement of
control unitstechnicalopinion
MAINTENANCE
− Onetime or contract over 3 years - guaranteed pricestability over the whole contract period
− Scheduling at the end of a year for the following
− Service technicians on duty: Wuppertal, Berlin, Stuttgart, Hamburg, and Munich
5
Technical know-how and service for your safety, according to the european policy.
MAINTENANCE | BENEFITS
− Reliability performance for the maximum safety in case of fire
− Long working life and prevention of failures
− Preservation of insurance coverage and prevention of financialpenalties
6
Yearly maintenance according to law and safety-related terms
Compliance with documentary obligation and detailedmaintenance protocol
Compliance with building regulations (repair work)
7
HEIKO WÜSTENHAGENPurchasing/Spare Parts Management
Phone: + 49 (0) 3328 326 72 31Fax: + 49 (0) 3328 326 72 12E-Mail: [email protected]
SPARE PARTS SERVICE CONTACT
You can count on us in case of need.
− Quick solutions for less failure time
− Short delivery times (standard spare parts)
− Flexible coordination of necessaryrepair work
− Well-equipped and professional technicians
9
REPLACEMENT OF CONTROL UNITS
The control unit is an important part of yourfire protection system and essential for itsfunctionality.
An ongoing technical progress and new legal requirements cause changes and the need tomodernize old systems.
We can make sure that your fire protection system is always ready for use with an update of your control units.
Your control unit needs an update?
Our fire shutters are suitable for all industrial branches. They are planned and installed individually for your specific needs. All fire shutters can be made of stainless steel, if required.
In the area of conveyor technology our fire shutters are convenient both for intermittent and continuously conveyor systems, for example carrying chain-, belt-, and roller conveyor.
Normally the fire shutters will be kept open above the wall opening with help of the catch system (magnetic clamp).
In case of a fire alarm initiated by the built-in smoke detector, the fire shutters automatically fill in the gap of the conveyor systems.
If you choose the power-driven completion, all functionalities can be operated directly via control unit of the conveyor systems and via local manual switch.
Category: Fire resistance class EI90
Scope of application: Model series 100E – EI90
Sizes: max.width. 1500mm
max. height: 1500mm
(Large openings could require permission in individual cases)
Test regulations EN 1363-1 & EN 1366-7
Admission VKF No. 125596
Fire doors and gates
Space-saving fire shutters as a clap Characteristics
Our sliding doors are suitable for all industrial branches. They are planned and installed individually for your specific needs. All sliding doors can be made of stainless steel, if required.
In the area of conveyor technology our sliding doors are convenient both for intermittent and continuously conveyor systems, for example carrying chain-, belt-, and roller conveyor.
Normally the sliding doors will be kept open besides, above or under the wall opening with help of the catch system (magnetic clamp).
In case of a fire alarm initiated by the built-in smoke detector, the sliding doors automatically fill in the gap of the conveyor systems.
If you choose the power-driven completion, all functionalities can be operated directly via control unit of the conveyor systems and via local manual switch.
Category: Fire resistance class EI90
Scope of application: Model series 100E – EI90
Sizes: max.width. 3600mm
max. height: 3500mm
(Large openings could require permission in individual cases)
Test regulations EN 1363-1 & EN 1366-7
Admission VKF No. 18945
Fire doors and gates
Horizontal and vertical sliding doors Characteristics
CONTACT
gte Service GmbH P: + 49 (0) 202 963 118 00Administration F: + 49 (0) 202 963 118 11Baerenstrasse 11-13D-42117 Wuppertal [email protected] www.gteservice.de
gte Service GmbH P: + 49 (0) 3328 326 72 00Technical Office F: + 49 (0) 3328 326 72 12Hauptstrasse 6D-14979 Großbeeren [email protected] www.gteservice.de