    FIS2000

    Remote Fiber Test System

    System Description

    PolarLink Technologies, Ltd.

  • 7/29/2019 gsm field trial

    2/20

    i

    Table of Contents

    1 Overview................................................................................................................1

    2 Definitions..............................................................................................................2

    3 System Structure ....................................................................................................4

    4 Test on the Fibers ...................................................................................................5

    5 System Functions...................................................................................................8

    6 Connection & Communication ............................................................................16

    7 Environmental Specifications ..............................................................................17

    8 Compliance ..........................................................................................................17

    Contact Information.....................................................................................................18

  • 7/29/2019 gsm field trial

    3/20

    FIS2000 Remote Fiber Test System System Description

    1

    1 Overview

    The FIS2000 Remote Fiber Monitoring Systemis designed to meet the need of cable

    maintenance and management. The internal design / manufacturing, and control of crucial

    RFTS technology ensure to offer the best solution. We aim for highest quality, humanizedtechnology, and good service to provide the advanced product. FIS2000 consists of OTDR and

    OCS to monitor, test, and record optical fibers 7-24-365 without interrupting transmission.

    Besides network monitoring, rapidly offering detailed fiber information and alarm location,

    FIS2000 also performs multiple test modes, such as on-line test (Active Fiber), off-line test

    (Dark Fiber), and real-time test. Moreover, The FIS2000 executes multiple test analyses,

    offers GIS to do fiber test and alarm location. The functions of cable management and analysis

    assist the administrator to fully understand cable status. Referring to scalability and stability,

    the FIS2000 adopts modular design, which facilitates future expansion. Also, all its modules

    and components feature high stability. Its very easy to install, operate, and maintain the

    FIS2000.

    The FIS2000 complies with general standards and regulations, such as

    1. Bellcore GR-1309-CORE, TSC/RTU Generic Requirements for Remote Optical Fiber

    Testing and Related Access and Test Messages.

  • 7/29/2019 gsm field trial

    4/20

    FIS2000 Remote Fiber Test System System Description

    2

    2 Definitions

    Item Descriptions

    TSC

    Test System Controller. The TSC is installed in the system controlling

    center. It can through DCN or IP-VPN receives alarms from RTUs andcommand RTUs to manage data, test fibers and so on.

    WS

    Work Station. The WS is installed at maintenance unit which means

    the FIS2000 supports multiple work station environments; it can query

    data and test fibers through TSC.

    RTU

    Remote Test Unit. The RTU is a test unit installed in equipment rooms

    to test fibers. The RTU can accommodate MCU module, PSU, OTDR,

    OCS, LSU, PMU, WDM, filter, splitter, etc.

    OTAU

    Optical Test Access Unit. The OATU is equipped with MCU and OCS.

    The OTAU receives TSCs command to switch the otpical route to the

    fiber under test.

    PSUPower Supply Unit. The PSU is centralized power supply. It could offer

    2 independent powers, DC(-36~-72V)+AC(11020V/22020V).

    MCU

    Monitor & Control Unit. The MCU is main control module of RTU. It is

    responsible for RTU auto-monitoring, controlling test schedule,

    analyzing and storing data, etc. With the MCU, the RTU can connect

    and communicate with TSC by LAN (10/100 Base-T Ethernet). The

    PSTN is also provided for redundancy.

    OTDR

    Optical Time Domain Reflector. The OTDR is the main equipment

    module to test optical fiber. It is controlled by the MCU module. It sends

    the testing signal to tested fiber according to test schedule.

    OCS

    Optical Channel Selector. The OCS is the optical switch module of

    RTU. It is controlled by the MCU module to switch the optical channel to

    the specified channel according to test schedule. Without OCS, RTU

    could not test many optical fibers.

    LSU

    Light Source Unit. The LSU is a module of RTU, and it is composed of

    major light source, redundant light source, coupler, splitter, etc. The

    LSU is controlled by the MCU module. The TSC can remotely switch

    the LSU to the major or redundant light source to emit the light. The

    LSU is used in the off-line real-time testing architecture to offer the light

    source to PMU so that PMU could real-time monitor the optical power.

  • 7/29/2019 gsm field trial

    5/20

    FIS2000 Remote Fiber Test System System Description

    3

    Item Descriptions

    PMU

    Power Monitor Unit. The PMU is a module of PMU. It receives optical

    power of monitored channel anytime. The PMU is controlled by the test

    procedure; it can accept test command and issue optical power alarm.

    WDM

    Wavelength Divided Multiplexer. The WDM is a module of RTU, and

    it is a passive component to multiplex or de-multiplex OTDR testing

    wavelength (1550nm or 1625nm optical window) and transmission

    wavelength (1310nm or 1550nm optical window).

    FilterThe Filter is a module of RTU, and it is a passive component to filter

    unwanted wavelength.

    SplitterThe Splitteris a module of RTU, and it diverts 5% of received power to

    the PMU for power monitoring.

    Power of Optical

    Channel

    The power of optical channel is the optical power of tested channel in

    the receive end.

    Optical

    PerformanceThe optical performance is the OTDR trace of tested channel.

    Channel NoThe channel number is the serial number of channel connected to RTU,

    e.g. Ch 12.

    Major Alarm

    Threshold

    When the variation of tested optical power and original trace reference

    exceeds the major alarm threshold, major alarm will be triggered.

    Threshold could be set by customer.

    Minor Alarm

    Threshold

    When the variation of tested optical power and original trace reference

    exceeds the minor alarm threshold, minor alarm will be triggered so that

    maintenance can be made before transmission quality is affected.

    Threshold could be set by customer.

  • 7/29/2019 gsm field trial

    6/20

  • 7/29/2019 gsm field trial

    7/20

    FIS2000 Remote Fiber Test System System Description

    5

    4 Test on the Fibers

    The FIS2000 offers two testing structures, off-line testing and on-line testing. The off-line

    testing uses the dark fiber for testing, while the on-line testing uses the active fiber for testing.FIS2000 has real-time alarm function in order to test fiber and report the result to related

    personnel immediately when fiber-break or aging. System can store the information of alarm

    time , alarm date, alarm status and so on to save the maintenance time and manpower.

    4.1 Testing Structure

    1. Off-line Real-time Testing

    The OTDR is testing on the dark fiber. However, through the PMU and LSU

    configuration, still the operator can receive the alarming message within very short

    period when the fiber got cut. This is the most cost effective way for the real-time

    testing.

    2. On-line Real-time Testing

    The OTDR is testing on the active fiber. And together with the PMU and LSU, the

    operator can receives the alarming message. The On-line mode provides more

    accuracy and shorter responsive time than the Off-line testing mode.

    4.2 Testing Type

    System offers 4 types of test functions, regular test, daily test, on-demand test and

    real-time test.

    1. Regular Test

    Regular testing function is automatically performed by RTU. RTU will test fiber

    regularly according to the users period setting.

    Regular test has the following features:

    Auto-testing dark fiber or active fiber without affecting transmission.

    Setting up test core ID, core number, test schedule, and record time.

    Comparing test result and original trace reference.

    Querying the conditions of every core and the system, offering hardcopy.

    Auto-triggering alarm and offering hardcopy.

  • 7/29/2019 gsm field trial

    8/20

    FIS2000 Remote Fiber Test System System Description

    6

    2. Daily Test

    RTU will do daily test according to the users date setting, and will record test result

    and trace. System will save the test trace accordingly for the users analysis and

    comparison.

    2. On-demand Test

    System offers the function of on-demand test. While necessary, TSC can command

    RTUs or WS through TSC to measure the optical performance of specified fiber,

    RTUs shall offer the measurement result. This function can allow the user to test any

    particular fiber they want, meanwhile the system will temporaily stop the regular test

    and perform the on-demand test immediately(real-time). After finishing the test,

    RTUs shall offer the measurement result immediately. Meanwhile, the regular test

    status can be recovered immediately. This function wont affect transmission quality.

    Besides, the user can compare test result and reference data.

    3. Real-Time Alarm Test

    When the TSC receives real time alarm from RTUs, it shall command RTUs to

    measure optical performance of monitored channel to find out the factor and location

    of failure.

    After RTUs start up, they shall automatically run real time testing procedure.

    1) Reading: receives commands from the TSC and gets the optical powers of

    monitored channels.

    2) Confirmation: Sets up confirmation interval (0~300 seconds). To avoid false

    alarm, after the confirmation interval, RTUs will automatically test channels

    again. If the alarm is confirmed, RTUs shall send the alarm to the TSC.

  • 7/29/2019 gsm field trial

    9/20

    FIS2000 Remote Fiber Test System System Description

    7

    4.3 System Component

    The FIS2000includes RTU, TSC, and WS. Please refer to the following table for system

    components.

    Item Components

    1. Server (PC specifications shall be specified by the customer)

    2. Database (MS SQL Server)

    3. Operating System

    4. TSC Software

    5. GIS

    6. Antivirus Software

    7. Firewall

    TSC

    8. Printer

    1. PC (PC specifications shall be specified by the customer)

    2. Operating System

    3. WS Client Software or BrowserWS

    4. Antivirus Software

    1. Chassis (19 or 23)

    2. PSU

    3. External Alarm Module

    4. MCU (Control & Management Module)

    5. OTDR

    6. OCS (Optical Channel Selector)

    7. LSU

    8. PMU

    9. WDM

    10. Filter

    11. Splitter

    12. Connector and patch cord

    RTU

    13. Monitoring software

    1. RTU Chassis

    2. PSU Module

    3. MCU ModuleOTAU

    4. OCS Module

  • 7/29/2019 gsm field trial

    10/20

    FIS2000 Remote Fiber Test System System Description

    8

    5 System Functions

    5.1 TSC (Test System Controller)

    The TSC Includes legally authorized operating system, database, and monitoring

    software. The TSC provides the functions of security management, datamanagement, element network management, alarm notification, degradation

    comparison, remote testing, GIS, hardcopy, etc. TSC operation can be stopped by

    the administrator manually and via software control remotely.

    TSC offers analyses of fiber degradation, event, fault type, and fault factor. These

    useful information could help to predict problem fiber, so that the manager can do

    the prevention and improvement in advance.

    5.2 WS

    The WS is the Clientfor access system data and information through connecting

    TSC Server by IP network. It can offer the functions of security management, data

    management and hardcopy, alarm notification, remote testing, GIS, etc. There are

    two ways to achieve these functions: one is using the Client Software, the other is

    using Web Browser.

    If the user uses the WS Client Software, we call this WS as PC Client.

    If the user uses the Web Browser, we call this WS as Web Client.

    Working environment: Windows 2000 Server or higherNetwork environment: TCP/IP TCP communication

    5.3 RTU

    The RTU includes operating system, monitoring software (RTUware), offers

    security and data management, executes test function, issues alarms, provides

    network management, etc. The RTU can operate independently without connection

    to TSC.

    5.4 Function List

    Functions Descriptions

    Security

    Management

    To ensure the system security, administrators and operators must

    key in account and password to log in.

    1. Authentication:

    1) To access to the system, the user must pass the

    authentication about account and password.

  • 7/29/2019 gsm field trial

    11/20

    FIS2000 Remote Fiber Test System System Description

    9

    Functions Descriptions

    2) RTUs shall pass the authentication while report to the

    TSC.

    2. AuthorizationThere are four (4) levels of user authentication, allowing

    authorized user to manage the RFTS system at different

    authorization level. The highest level authorized user is

    allowed to manage all of the settings, overseeing all the

    lower level users. According to the different authorization

    level, user can adds, modifies and deletes the RTU or fiber

    route in the specific RTU of specific areawhenever they

    want.

    System allows users to access at the same time:

    PC Client: more than 10 users

    Web Browser: more than 100 users

    3. Connection management

    4. Group user management

    5. Account, password management:

    1) Adds, modifies, deletes account and password for

    access to the TSC.

    2) Adds, modifies, deletes account and password for

    access to RTU.

    3) System will record Login and working status of each

    account.

    6. System can detect and protect form unauthorized access,

    damage and interference.

    Data Management

    1. Device data: adds, modifies and deletes system IP address, ,

    net mask, gateway, TCP port number, system date and time.

    2. Control parameters & data management:

    1) Original data setup and storage while system start-up.

    Stores status of every monitored optical fiber route

    (normarl, abnormal, or alarm), optical power, and OTDR

    trace.

    2) Adds, modifies, deletes Cable ID, Cable Type, Fiber ID,

    Fiber Type, Starting Station and Ending Station, Cable

    Project, Fiber Count, Installation Type, Fiber Usage,

  • 7/29/2019 gsm field trial

    12/20

    FIS2000 Remote Fiber Test System System Description

    10

    Functions Descriptions

    Distance between nodes(manhole, hand-hole, pole, or

    splice point), monitored optical fiber route number and

    name, original optical power, major/minor alarmthresholds, and confirmation interval.

    3) Adds, modifies, deletes optical parameter, OTDR Trace

    reference and OTDR Events and Fiber Length of

    monitored channel, major/minor alarm thresholds.

    4) Adds, modifies, deletes tested channels of RTUs,

    recording time, and regular test schedule.

    5) Periodically reads, stores regular test data of RTUs, and

    sets up reading cycle.

    6) RTU working parameters configuration.

    7) Responsible stuff note.

    8) Staff information of Maintenance: including name of in

    charge person, Address, Telephone or Cellular phone

    number, Fax number and E-Mail address.

    9) Customer information: including customer name,

    Address, Telephone or Cellular phone number, Fax

    number and E-Mail address.

    3. By password control, the TSC allows WS to query fiber status,

    system data, real time alarm (alarm cause report), test data

    (OTDR traces) and history data through Web Browser.

    Data TransferringTool

    The system offers the GUI tool for operation status detection and

    Input / Output data transferring.

    Element NetworkManagement

    1. The TSC can connect to RTU by LAN and PSTN, and connect

    to WS by IP network.

    2. Maximum RTU management: 256

    3. Maximum WS co-work service: 256

    4. RTU status collection.

    ModuleManagement

    1. After RTUs starts up, they shall automatically execute the

    function of module management.

    2. RTUs can detect the operation of modules. If LSU, PMU,

    OCS, OTDR damages, RTUs shall automatically trigger the

    alarm to the TSC.

    3. Maximum fiber channel : 96

  • 7/29/2019 gsm field trial

    13/20

    FIS2000 Remote Fiber Test System System Description

    11

    Functions Descriptions

    Alarm Handling

    System will send alarms to TSC while testing and confirming the

    optical power is below the preset minor/major threshold,

    hardware/module failure, or fiber break. After repairing, RTUs willsend a recovery message to TSC and command OTDR to test

    fiber quality (compare with original trace) automatically to confirm

    the fiber status. System status will back to normal after

    confirmation.

    When TSC received the alarm message from RTUs, TSC will

    1. Trigger visual, audio alarms.

    2. Inform related personnel by SMS (Short Message Service).

    3. Inform related personnel by email.

    4. Display fault location on the GIS.

    5. Set up alarm record and keep in history report.

    6. Continued alarm information correction.

    7. Make hardcopy (Option).

    Alarm includes Major alarm & Minor alarm which can be

    defined by user. Different alarm level will display in different color.

    Alarm information includes Fiber break alarm & Fiber

    characteristic alarm.

    Fiber break alarm includes information of alarm status, alarm ID,

    date and time of alarm, date and time of recovered, fault location,

    optical distance, geographic distance etc.

    Fiber characteristic alarm includes information of date and time,

    fiber ID, status, span loss, splice loss, connector etc.

    DegradationComparison &

    Analysis

    The TSC can query, display, print the latest test data, and

    compares with original data for degradation analysis.

    Scan Trace Event

    1. RTU can scan and analyze the event of OTDR trace,

    including reflective and non-reflective type.

    2. The number of trace event: More than 256.

    Remote Test

    1. The TSC can remotely test monitored channels, display,

    store, and print optical power and OTDR trace.

    2. The WS can execute test function through TSC.

  • 7/29/2019 gsm field trial

    14/20

    FIS2000 Remote Fiber Test System System Description

    12

    Functions Descriptions

    3. OTDR simulator.

    GIS

    Integrates GIS information compatible with MapInfo.

    1. Layer setup:1) Imports GIS map format compatible with MapInfo.

    2) Offers layer management tool.

    3) Changes background color.

    2. Unit setup:

    1) Offers WGS84 coordinate system.

    2) Distance unit: meter (m)

    3. Display setup:

    1) Sets up icon and size of RTUs.

    2) Sets up icon and size of channel start and end.

    3) Sets up line style and width.

    4) Sets up icon and size of reference landmark.

    5) Sets up icon and size of alarm.

    6) Labels icon.

    4. Basic operation:

    1) Zooms in/out on map.

    2) Pans on map.

    3) Draws, modifies dot data, e.g. RTU.

    4) Draws, modifies line data, e.g. channel.

    5. Map view:

    1) Offers reference map windows to view different

    monitored scopes.

    2) Views alarm location.(including status of route and which

    occur error). The error route will be displayed in different

    color and the icon blinks.

    6. Data relation:

    1) Offers RTU mapping.

    2) Offers channel mapping from starting point to terminal

    point.

    3) Offers cable mapping.

    GIS mapTransferring

    We could use GIS Data Management Tool (MapInfo

    Professional, optional) which can transfer the the AutoCAD

    file(.DWG or DXF) or other GIS map such as ArcInfo GIS map

  • 7/29/2019 gsm field trial

    15/20

    FIS2000 Remote Fiber Test System System Description

    13

    Functions Descriptions

    (ESRI file .E00 or Shape) or Intergraph file(.DGN) to MapInfo

    format. The tool can handle both Graphic data and non-Graphic

    data (Scalar Attribute).

    Report &Hardcopy

    1. Optical power test data: Including RTU location, device port

    number, channel number, fiber number, name, status, test

    result, reference optical power, optical power variation, optical

    power threshold, test date and time, etc.

    2. Test comparison: Including RTU location, device port number,

    channel number, fiber number, name, OTDR trace

    comparison, test date and time, etc.

    3. Fiber alarm statistics: including alarm ID, alarm status, RTU

    location, device port number, channel number, fiber number,

    name, alarm occurrence time, failure location, measured

    optical power, reference optical power, optical power

    variation, optical power threshld, test date and time, etc.

    4. Basic data of monitored channel and repair record: OTE, RTU

    No, device port number, cable name, channel, type, date of

    establishment completion, repair record, date and time of

    hardcopy, etc.

    5. The WS can receive and store periodic data from the TSC,

    and it can query, display, and print measured optical power

    and test data.

    6. History report.

    7. RTU devise alarm information.

  • 7/29/2019 gsm field trial

    16/20

    FIS2000 Remote Fiber Test System System Description

    14

    5.5 Database

    1. DatabaseThe system uses Microsoft SQL Server 2000 Relational DataBase

    Management System (RDBMS) which complies with Open Database

    Connectivity Standard.2. ODBCThe system could through ODBC(Open DataBase Connectivity) link

    with other database system such as Oracle (support version 10g or above).

    3. Database Table relationship of RFTS

  • 7/29/2019 gsm field trial

    17/20

    FIS2000 Remote Fiber Test System System Description

    15

    5.6 RFTS Software Client / Server Relationship Description

    RFTS programs take the role for all required function about testing and monitoring

    functions. The whole RFTS system programs divide into 3 working layers.

    4. Workstation Layer (Client)Workstation layer programs take the responsibility for system operation GUI

    interface. It runs with web service for any web client request. RFTS

    workstation uses web browser to operate all fiber testing and alarm monitoring

    functions.

    5. TSC Layer (Server)

    TSC layer programs take the responsibility for system cycle monitor work.

    TSC daemon link with SQLDB server by MS ODBC interface. It includes TSC

    GUI program, TSC daemon, and TSC command forward server.

    6. RTU Layer (Client)

    RTU layer server for any filed fiber testing works. It includes RTU server

    program which handle the RTU hardware devices driving.

    7. Web programs link with SQLDB server by MS ODBC interface.

    8. SQL Server uses DB Mirror for database backup technique.

    M.S. SQL

    Backup

    TCP/IP Protocol

    Web Browser

    Client Site

    M.S. SQL

    Main D.B

    Firewall

    Web GUI and RTU

    Operation Program

    Web GUI and RTU

    Operation Program

    Load Balance

    Workstation Layer

    TCP/IP Protocol

    TSC Layer

    TSC UI Program

    TSC Server

    RTU Command

    Forward Server

    Program

    TSC UI Program

    TSC Server

    RTU Command

    Forward Server

    Program

    Web Browser

    Client Site

    Web Browser

    Client Site

    RTU Monitor and

    Test program

    RTU Monitor and

    Test program

    RTU Monitor and

    Test program

    RTU Monitor and

    Test program

    RTU Monitor and

    Test program

    RFTS

    RTU Layer

    Backup

  • 7/29/2019 gsm field trial

    18/20

    FIS2000 Remote Fiber Test System System Description

    16

    6 Connection & Communication

    The connection and communication specifications focus on the connection between TSC

    and RTU, WS.

    6.1 Communication & protocol

    Item Specifications

    Network Interface Card 10/100 Mbps (auto detection)

    Interface LAN (10/100 Base-T Ethernet), RJ-45 connector

    Protocol TCP/IPSNMP

    6.2 Communication Failure

    Item Specifications

    PriorityThe LAN is the first choice for connection, and

    the PSTN serves as redundancy.

    Communication Failure Display

    In case of communication failure between RTU

    and TSC, the system shall display the

    communication failure.

    Retry for Communication Failure

    When the communication between RTU and

    TSC fails, the system shall retry for 3 times.

    After 3-time retrying, the system shall abort this

    command or proceed the next command.

    .

  • 7/29/2019 gsm field trial

    19/20

    FIS2000 Remote Fiber Test System System Description

    17

    7 Environmental Specifications

    Item Specifications

    Operating Temperature 0~45CStorage Temperature -10~60C

    Relative humidity 5~85% (non-condensing)

    8 Compliance

    The FIS2000 complies with the regulations of Bellcore GR-1309-CORE.

  • 7/29/2019 gsm field trial