GSE EnVision ProcessFund Sim I

download GSE EnVision ProcessFund Sim I

of 2

Transcript of GSE EnVision ProcessFund Sim I

  • 8/20/2019 GSE EnVision ProcessFund Sim I

    1/2

    Gas & Liquid Flow: This simulation model helps inunderstanding the dynamics of gas flow and liquid flowthrough a valve in a pipeline and various control valvefailures, including Stick and Slip. The Gas consists of twoelements namely Nitrogen and Hydrogen. Water is used asa liquid medium.

    Pipe Flow Network: This model consists of two pipesconnected via a T-Junction to a single pipe. Water is usedas the fluid medium. The trainee learns about the dynamicsof flow, pressure, temperature, mass and heat balance andprocess control.

    Tank and a Pump: This model consists of two tanks andpumps. Water is used as the fluid medium. Water entersthe first tank under tank level control and leaves the firsttank under flow control, to enter the second tank. Waterleaves the second tank under second tank level control.The trainee learns about pump and motor dynamics andfluid transfer.

    Process Fundamentals–I Simulation

    GSE Systemswww.gses.com/EnVision

    The Process Fundamentals simulation is a series of rigorous and high-fidelity process equipment models that provide a

    realistic response for process dynamics, equipment principles, operating principles and process control.

    • Simulation comes with a Learning Management System (LMS) called SimAdmin that allows an instructor to registertrainees and monitor their performance

    • Simulation is available as Standalone (Single or Dual Monitor) and Instructor-Trainee versions

    EnVisione-Learning & Universal Simulation

  • 8/20/2019 GSE EnVision ProcessFund Sim I

    2/2

    Single Phase Heat Exchanger:  This model consists of atypical single-phase heat exchanger with a bypass line onone flow. Hot and cold Water are used as fluid medium.

    The trainee learns about heat exchanger principles andcommonly used temperature control strategies.

    Tank, Pumps and a Heat Exchanger: This integrated modelconsists of tank, pumps and heat exchanger with variouscontrol strategies. Hot water is cooled by cold water at aheat exchanger before entering the tank with a level-flowcascade control. Flow leaving the tank is pumped undera flow control. The trainee learns about normal, startup,shutdown and troubleshooting operations.

    Process Fundamentals–I SimulationEnVision

    EnVision

    EnVision™ is a trademark of GSE Systems, Inc. All other trademarks are the property of

    their respective owners. The information in this literature is subject to change without

    notice and is not to be construed as a warranty.

    DS.ENV.34.VB 12/14

    Single Phase Heat Exchanger – Hot Bypass Control:  Thismodel consists of a single phase heat exchanger with hotbypass control. Hot and cold water are used as fluid medium.

    The trainee learns about heat exchanger principles and avariation in the temperature control strategy.

    Air Cooler: This model consists of a typical air cooler. Theprocess fluid is hot water and the cooling medium is air. Thetrainee learns about air cooler principles and temperaturecontrol strategies.

    GSE Systems, Inc.

    1332 Londontown Boulevard,

    Suite 200, Sykesville, Maryland

    21784 USA

    T: +1 410.970.7800

    T: 800.638.7912 (U.S. only)

    F: +1 410.970.7997

    E: [email protected]