System Installation Guide GS-SR147S 1U Rack Mount Server Pentium ® 4 Processor Serv erboard Rev . 1001 P/N

Transcript of GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire,...

Page 1: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

System Installation Guide

GS-SR147S 1U Rack Mount Server

Pentium®4 Processor ServerboardRev. 1001

P/N

Page 2: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

2

GS-SR147S Rack mount Serv er

Table of Content

Safety, Care and Regulatory Information ............................................3Introduction ......................................................................................7Contents Packages ..........................................................................7WARNING! .......................................................................................7Chapter 1 Features Summary ............................................................8Chapter 2 System Overview............................................................ 10Chapter 3 System Hardware Installation ........................................... 11

Step 3-1: Chassis Remov al ......................................................................... 11Step 3-2: CPU Installation ............................................................................ 12Step 3-3: Heat Sink Installation ..................................................................... 13Step 3-4: Memory Installation ....................................................................... 13Step 3-5: PCI Ex pansion Card Installation ...................................................... 14Step 3-6: Hard Disk Driv e Installation ............................................................. 15Step 3-7: FAN Duct Remov al and Installation ................................................. 16Step 3-8: Reinstall Chassis Cov er ................................................................ 16

Chapter 4 Appearance of GS-SR147S ............................................. 174-1: Front View of GS-SR147S .................................................................... 174-2: Rear View of GS-SR147S ..................................................................... 184-3: Sw itch and LED Indicators Description .................................................... 194-4 : Connector Icon Description ................................................................... 20

Chapter 5 Appendix ........................................................................ 215-1: Acrony ms .......................................................................................... 21

Page 3: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

3

Safety Information

Safety, Care and Regulatory InformationL Important safety information

Read and follow all instructions marked on the product and in the documentation before you operateyour system. Retain all safety and operating instructions for future use.* The product should be operated only from the type of power source indicated on the rating label.* If your computer has a voltage selector switch, make sure that the switch is in the proper position foryour area. The voltage selector switch is set at the factory to the correct voltage.* The plug-socket combination must be accessible at all times because it serves as the main disconnect-ing dev ice.* All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type poweroutlet. This is a safety feature. The equipment grounding should be in accordance with local and nationalelectrical codes. The equipment operates safely when it is used in accordance with its marked electricalratings and product usage instructions* Do not use this product near water or a heat source.* Set up the product on a stable work surface or so as to ensure stability of the system.* Openings in the case are prov ided for ventilation. Do not block or cover these openings. Make sure youprov ide adequate space around the system for ventilation when you set up your work area. Never insertobjects of any kind into the ventilation openings.* To av oid electrical shock, always unplug all power cables and modem cables from the wall outletsbefore removing covers.* Allow the product to cool before removing covers or touching internal components.

L Precaution for Product with Laser DevicesObserve the following precautions for laser dev ices:

* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser dev ice other thanthose specified in the product's documentation.* Only authorized serv ice technicians should repair laser dev ices.

L Precaution for Product with Modems, Telecommunications, ot Local Area

Network OptionsObserve the following guidelines when working with options:

* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electricalshock from lightning.

Page 4: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

4

GS-SR147S Rack mount Serv er

* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.* Disconnect the modem cable before opening a product enclosure, touching or installing internalcomponents, or touching an uninsulated modem cable or jack.* Do not use a telephone line to report a gas leak while you are in the v icinity of the leak.

L Federal Communications Commission (FCC) Statement

Note: This equipment has been tested and found to comply with the limits for a Class B digital dev ice,

pursuant to Part 15 of the FCC Rules. These limits are designed to prov ide reasonable protection againstharmful interference w hen the equipment is operated in a commercial env ironment. This equipmentgenerates, uses, and can radiate radio frequency energy and, if not installed and used in accordance withthe instruction manual, may cause harmful interference to radio communications. Operation of thisequipment in a residential area is likely to cause harmful interference in which case the user will berequired to correct the interference at his own expense.Properly shielded and grounded cables and connectors must be used in order to meet FCC emissionlimits. Neither the prov ider nor the manufacturer are responsible for any radio or telev ision interferencecaused by us ing other than recommended cables and connectors or by unauthorized changes ormodifications to this equipment. Unauthorized changes or modifications could void the user's authority tooperate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this dev ice may not cause harmful interference, and(2) this dev ice must accept any interference receiv ed, including interference that may cause undesiredoperation.

L FCC part 68 (applicable to products fitted with USA modems)The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, amongother information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment.You must, upon request, prov ide this information to your telephone company.If your telephone equipment causes harm to the telephone network, the Telephone Company maydiscontinue your serv ice temporarily . If possible, they will notify in advance. But, if advance notice is notpractical, you will be notified as soon as possible. You will be informed of your right to file a complaint with

the FCC.

Page 5: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

5

Safety Information

Your telephone company may make changes in its fac ilities, equipment, operations, or procedures thatcould affect proper operation of your equipment. If they do, you will be notified in advance to give you anopportunity to maintain uninterrupted telephone serv ice.The FCC prohibits this equipment to be connected to party lines or coin-telephone serv ice.The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part68, Sec. 68.381 (c) (3))./ for Canadian users only /

L Canadian Department of Communications Compliance Statement

This digital apparatus does not exceed the Class B limits for radio noise emissions from digitalapparatus as set out in the radio interference regulations of Industry Canada.Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables auxappareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte parIndustrie Canada.

L DOC notice (for products fitted with an Industry Canada-compliant modem)

The Canadian Department of Communications label identifies certified equipment. This certificationmeans that the equipment meets certain telecommunications network protective, operational and safetyrequirements. The Department does not guarantee the equipment will operate to the user satisfaction.Before installing this equipment, users ensure that it is permissible to be connected to the facilities of thelocal Telecommunications Company. The equipment must also be installed using an acceptable methodof connection. The customer should be aware that compliance with the above conditions might not preventdegradation of serv ice in some situations.Repairs to certified equipment should be made by an authorized Canadian maintenance facility designatedby the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions,may give the telecommunications company cause to request the user to disconnect the equipment.Users should ensure for their own protection that the electrical ground connections of the power utility ,telephone lines and internal metallic water pipe system, if resent are connected together. This precautionmay be particularly important in rural areas.Caution: Users should not attempt to make such connections themselv es, but should contact the

appropriate electric inspection authority , or electrician, as appropriate.

Page 6: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

6

GS-SR147S Rack mount Serv er

NOTICE: The Load Number (LN) assigned to each terminal dev ice denotes the percentage of the totalload to be connected to a telephone loop which is used by the dev ice, to prevent overloading. Thetermination on a loop may consist of any combination of dev ices subject only to the requirement that the

sum of the Load Numbers of all the dev ices does not exceed 100.

/ for European users only /

CAUTIONv Danger of explosion if battery is incorrectly

replaced.v Replace only with the same or equivalent

type recommended by the manufacturer.v Dispose of used batteries according to the

manufacturer’s instructions.

Page 7: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

7

Introduction

þ Chassis þ GS-8IKHXR Motherboard (Installed)þ Power Supply (Installed) þ CPU Heat Sink x 1þ FAN Duct x 1 þ Slim type CD-ROM drive (Installed)þ Standard Floppy Drive (Installed) þ GS-SR147S User’s Manualþ Cables (CD-ROM, Floppy) þ Driver CD for motherboard driver & utilityþ HDD Trays x 2 (Installed)

IntroductionWelcome to Gigabyte GS-SR147S Rack mount Server System Installation Guide. The guide

prov ides instructions for configuration hardware for the GS-SR147S your system.This installation guide will assiste you in installing all the essential components for the sever system.

For your protection, please read and undertand all of the safety and operating instructions regarding yourGigabyte Server and retain for future reference. The procedures in this guidebook assusme that your area system or network administrator experienced in installing similar hardware.

Contents PackagesWhen opening the package, please ensure the system components are not damaged during the shipping.Using the following checklist to v erify the contents. If any component is missing or damaged in thesystem, please contact your vendor immediately .

Computer motherboards and expansion cards contain very delicate Integrated Circuit (IC) chips. Toprotect them against damage from static electricity , you should follow some precautions whenever youwork on your computer.

1. Unplug your computer when working on the inside.2. Use a grounded wrist strap before handling computer components. If you do not have

one, touch both of your hands to a safely grounded object or to a metal object, such as the power supply case.

3. Hold components by the edges and try not touch the IC chips, leads or connectors, orother components.

4. Place components on a grounded antistatic pad or on the bag that came with thecomponents whenever the components are separated from the system.

5. Ensure that the ATX power supply is switched off before you plug in or remove the ATXpower connector on the motherboard.

WARNING!

Page 8: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

8

GS-SR147S Rack mount Serv er

Motherboard � GA-8IKHXRProcessor Supported � Supports Intel® P4 processor up to 3.6GHz

� Intel® P4 533/800MHz FSB� L2 cache on-die per processor from 512K

Chipset � Intel® E7210, 6300ESBSystem Memory:Memory Capacity � 4 x DDR socket up to 4 GBMemory Type � Un-buffered DDR 266/333/400DIMM Size � Support 128MB, 256MB, 512MB, and 1GB memoryError Correction: � Single-bit Errors Correction, Multiple-bit Errors DetectionExpansion Slot � Un-buffered, EC1 Butter-Fly Riser card supports up to 2 x 64/66

add-on cards (3.3V):� 1 x LP PCI add-on card (Half-High/Half-Length)� 1 x Full-Size add-on card (Full-High/Half-Length)

ATA RAID controller � Intel® 6300ESB� Supports SATA RAID 0,1

Cooling Fans: � 5 X System FanIntegrated LANs:Controller � Intel® 82541GI and 82547GI GbEAdvanced Software Function � Adapter Fault Tolerance

� Adaptive Load BalancingIntegrated Graphics:Controller � Integrated, ATI Rage-XLGraphics Memory � 8MB SDRAMMass Storage System � 2 x Hot-swap SATA HDD

� 1 x Standard Type FDD� 1 Slim Type CD-ROM

Chapter 1 Features Summary

Page 9: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

9

Feature Summary

Super I/OController � ITE8712F Super I/OBuilt-in I/O � 2 x serial Port (one at rear, other on front)

� 2 x USB ports on front plane, 2 x USB ports at rear� 1 x VGA connector� 2 x RJ45 LAN ports� P/S 2 Keyboard and Mouse Connectors

System BIOS:BIOS Type � Phoenix ® BIOS, Multi-boot BBS 1.0 Compliant4Mb Flash MemorySpecial Features � BIOS HW Monitoring reporting (The values monitored by HW

Monitoring chipset)� Console Redirection v ia COM ports� Intel® Hyper Threading Support� Resume after AC Back� Wake On LAN� ACPI 1.0 Compliant/ ACPI defined S1, S4, and S5

Server Management Functions:BMC Chip � NS IPMI 1.5 controllerFailure Detection � IPMI 1.5 specification of Server managementEvent Logging � 32KB Nonvolatile Memory to Log System Failure EventsRemote Management � Follow the IPMI 1.5 specification of Server managementEnvironmentAmbient Temperature � Operating Temperature: 5oC to 35oC

� Non-operating Temperature: 0oC to 50oCRelative Humidity � 10-80% operating Humidity at 30o CSafety Regulations � FCC, CE, BSMI, CB, Win2000, 2003 WHQLIPMI 1.5System Dimention: � 427.5mm x 521mm x 42.6 mmElectrical Power Supply � Single Power Supply 250W

Page 10: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

10

GS-SR147S Rack mount Serv er

Chapter 2 System Overview

Power Supply

FAN x 5

Slim type CD-ROM

Floppy Disk Drive

4 x DDR DIMM socket

CPU - Socket 478

1 Riser card with PCI -X full-height/full-length 64/66MHz; and one with PCI-X low-

profile 64-Bit/66MHz

Hot-swap SATA HDD x 2

Page 11: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

11

Hardw are Installation Process

Please observe the safety information in chapter “Important Safety Information”Do not expose the server to extreme env ironmental conditions. Protect it from dust, humidity ,and heat.

Step 3-1: Chassis Removal

Step 1 Unscrew the thumbscrew from the back of the system.Step 2 Push down the two buttons located at two sides of the chassis, and slide toward to remove the

top cover. After removing the chassis cover, you can install CPU and other essential components.

Chapter 3 System Hardware Installation

Step 1

Thumbscres

Step 2

Note: Before installing CPU, you must remove the FAN duct. For FAN duct removal, pleasesee Sub-section 3-7 “FAN Duct Removal and Installtion” for detail instruction.

Page 12: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

12

GS-SR147S Rack mount Serv er

Step 3-2: CPU Installation

Step 1 To install the CPU(s), lift up the bar that located next to the socket.Step 2 The noticed corner should point toward the end of lever. The CPU will only it in the orientation

as shown below.Step 3 Then, align the CPU and insert it into the socket.Then, push the lever to the original position.

Please make sure the CPU type and speed that are supported by the motherboard.

Step 3

Step 1 Step 2

Page 13: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

13

Hardw are Installation Process

Step 3-3: Heat Sink InstallationStep 1 Put the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember

to apply the thermal conductiv ity compound on the CPU.Step 2 Then, Seat the heat sink in the retention modules with the four screws. Installation completed.

Step 3-4: Memory InstallationStep 1 The DIMM slot has a notch, the DIMM memory module only fit in one direction.Step 2 Align the memory notch to the module and push the memory into the DIMM socket vertically .

Step 1

Notch

Step 2

Step 2

Page 14: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

14

GS-SR147S Rack mount Serv er

Step 3-5: PCI Expansion Card InstallationGS-SR147S prov ides expansion riser slots for one PCI-X full-height/full-length 64/66MHz; and one withPCI-X low-profile 64-Bit/66MHz. To install the peripheral, please go through the following steps.

Note!! Before installing the PCI expansion card, please check the card size limitation. Size limitation

for PCI-X full-height/full-length is 228.5 mm x 91.5 mm; size limitation for Low-Profile Card : 167.5 mmx 56 mm .

Step 1 Remove the screws on the riser bracket.Step 2 Detach the riser bracket with both hands.Step 3 Installing the PCI Riser card. To install the riser card, just simply push it into the module.Step 4 Finally , align the stable racks to the system module (see the arrow direction mark 1), and push

down vertically .Step 5 Reverse Step 1 & 2 to secure the riser bracket firmly . Installation completed.

Step 1 Step 2

Step 3 Step 4

Page 15: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

15

Hardw are Installation Process

Step 3-6: Hard Disk Drive InstallationStep 1 Pull out the Hard Disk tray.Step 2 Place hard disk into the hard disk tray.Secure hard disk in the hard disk tray with screws. For

security reason, you should tighten all screws into the pointed position.Step 3 Push the hard disk tray handle to the closed position. Connect the cables

Step 1 Step 2

Step 3

Page 16: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

16

GS-SR147S Rack mount Serv er

Step 3-8: Reinstall Chassis CoverStep 1 Close the cover in un-lock position. Slide it toward to lock position.Step 2 Make sure the thumbscrews are tightened.

Step 3-7: FAN Duct Removal and InstallationStep 1 To remove the FAN duct, just pull up the screw-holder and unscrew thumbscrews to remove the

FAN duct. (Please see the circle pointed to find the screw location)Step 2 For FAN Duct Installation, place the fan duct on the top of heat sinks. Fasten the screws to the

locked position and push down te screw-holders.

Step 1 Step 2

Step 1 Step 2

Page 17: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

System Appearance

17

4-1: Front View of GS-SR147S

Chapter 4 Appearance of GS-SR147S

u

v w

x y

u

v

w

x

y

z

z

Slim Type CD-ROM

Standard Floopy

RJ45 (For Console Redirection)

LEDs

USB connector

Hot-swap SATA HDDs

Page 18: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

18

GS-SR147S Rack mount Serv er

4-2: Rear View of GS-SR147S

u v

w x y z

{ |

u

v

w

x

|

y

z

{

}

Power

PS/2 Keyboard and Mouse Connectors

USB Connectors

COM Port

VGA Port

LAN1/2 Ports

Expansion Slot

Expansion Slot

Locate ID LED / Button}

Page 19: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

19

LED Description

4-3: Switch and LED Indicators Introduction

Power/Sleep

ID NMI LAN1/2 Activities

HDDStatus

HDD Fail Warning

NamePower

Status

HDD

LAN1/2Activ ity

Identification

Color Condition DescriptionGreen On Power OnGreen Blink Sleep (S1)-- Off Power Off (S4)Green On System Ready On/ AlarmAmber Blink System Ready but deqraded, CPU Failed,

DIMM KilledAmber On Critical Alarm: Critical Power Module Failure,

Critical FANs Failure, Voltage (Power Supply)Critical Teemperature and Voltage

-- Off System Not Ready/ Post error/NMI event/CPUor terminator missing

Green Blink Hard Disk Drive Access-- Off No Access and No HDD FaultGreen On LAN Link / No access 10M/100MGreen Blink LAN accessAmber On LAN Link 1000MAmber Blink LAN accessBlue Blink Unti selected for identification-- Off No identification

Page 20: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

20

GS-SR147S Rack mount Serv er

Suggest Icon Description

Keyboard

VGA

Mouse

LAN

Serial Port

USB

4-4 : Connector Icon Description

- ether-

Page 21: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

Appexdix

21

Acronyms MeaningACPI Advanced Configuration and Power InterfaceAPM Advanced Power ManagementAGP Accelerated Graphics PortAMR Audio Modem RiserACR Advanced Communications RiserBBS BIOS Boot SpecificationBIOS Basic Input / Output SystemCPU Central Processing UnitCMOS Complementary Metal Oxide SemiconductorCRIMM Continuity RIMMCNR Communication and Networking RiserDMA Direct Memory AccessDMI Desktop Management InterfaceDIMM Dual Inline Memory ModuleDRM Dual Retention MechanismDRAM Dynamic Random Access MemoryDDR Double Data RateECP Extended Capabilities PortESCD Extended System Configuration DataECC Error Checking and CorrectingEMC Electromagnetic CompatibilityEPP Enhanced Parallel PortESD Electrostatic DischargeFDD Floppy Disk DeviceFSB Front Side BusHDD Hard Disk DeviceIDE Integrated Dual Channel EnhancedIRQ Interrupt Request

5-1: Acronyms

Chapter 5 Appendix

Page 22: GS-SR147S 1U Rack Mount Server€¦ · 4 GS-SR147S Rack mount Server * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem

22

GS-SR147S Rack mount Serv er

Acronyms MeaningI/O Input / OutputIOAPIC Input Output Advanced Programmable Input ControllerISA Industry Standard ArchitectureLAN Local Area NetworkLBA Logical Block AddressingLED Light Emitting DiodeMHz MegahertzMIDI Musical Instrument Digital InterfaceMTH Memory Translator HubMPT Memory Protocol TranslatorNIC Network Interface CardOS Operating SystemOEM Original Equipment ManufacturerPAC PCI A.G.P. ControllerPOST Power-On Self TestPCI Peripheral Component InterconnectRIMM Rambus in-line Memory ModuleSCI Special Circumstance InstructionsSECC Single Edge Contact CartridgeSRAM Static Random Access MemorySMP Symmetric Multi-ProcessingSMI System Management InterruptUSB Universal Serial BusVID Voltage IDZCR Zero Channel RAID