Groundwater Advisory Unit

17
RAILROAD COMMISSION OF TEXAS Groundwater Protection Determination Letters Norman Gearhart, P.G. Manager Groundwater Advisory Unit

description

Groundwater Protection Determination Letters Norman Gearhart, P.G. Manager Groundwater Advisory Unit. Groundwater Advisory Unit. Purpose Provide recommendations for groundwater to be protected during oil and gas drilling and production. - PowerPoint PPT Presentation

Transcript of Groundwater Advisory Unit

Page 1: Groundwater Advisory Unit

RAILROAD COMMISSION OF TEXAS

Groundwater Protection Determination Letters

Norman Gearhart, P.G.Manager Groundwater Advisory Unit

Page 2: Groundwater Advisory Unit

Groundwater Advisory Unit

Purpose

• Provide recommendations for groundwater to be protected during oil and gas drilling and production.

• Evaluate Saltwater Disposal Well applications for geologic isolation from the base of usable-quality water and injection below the underground source of drinking water.

• Hydrogeological evaluation concerning groundwater contamination.

Page 3: Groundwater Advisory Unit

Protected Aquifers

For oil and gas wells

• Freshwater (less than 1,000 mg/l total dissolved solids, TDS), and

• Usable-quality water (less than 3,000 mg/l TDS, waters known to be used, and waters identified by the Texas Water Development Board for use in desalination)

For saltwater injection wells in addition to the above

• Underground source of drinking water (less than 10,000 mg/l TDS)

Page 4: Groundwater Advisory Unit

RAILROAD COMMISSION OF TEXAS

4

Page 5: Groundwater Advisory Unit

Types of Applications

• Surface Casing Applications

• Microseismic Applications

• Seismic Applications (shot holes)

• Saltwater Disposal Applications (W-14)

Page 6: Groundwater Advisory Unit

What Requires a Surface Casing Letter

• New Drills

• Well Integrity Test

• Plugging and Abandoning

• Cathodic Protection

• Microseismic Boreholes

• Re-entering a Well

Page 7: Groundwater Advisory Unit

7

Page 8: Groundwater Advisory Unit

8

Page 9: Groundwater Advisory Unit

Seismic Letter

• Send a Dated letter Including

– Company Name and Address

– Contact Person and Phone Number

– Project Name

– County Name(s)

– Shot Hole Depth

– Map Showing Shot Points

• Receive a Seismic Groundwater Protection Letter (Base of Usable-Quailty Water)

Page 10: Groundwater Advisory Unit

10

Page 11: Groundwater Advisory Unit

11

Page 12: Groundwater Advisory Unit

12

Page 13: Groundwater Advisory Unit

13

Base of Usable-Quality Water

Base Underground Source of Drinking Water

Carrizo

Page 14: Groundwater Advisory Unit

14

Page 15: Groundwater Advisory Unit

15

Page 16: Groundwater Advisory Unit

16

Page 17: Groundwater Advisory Unit

Contact Information

17

Milton Rister, Executive Director 512/463-7068 [email protected]

Gil Bujano, Director, Oil & Gas Division

512/463-4513 [email protected]

Ramon Fernandez, Deputy Director, Field Operations, Oil & Gas Division

512/463-6827 [email protected]

Norman Gearhart, P.G., Manger Groundwater Advisory Unit

512/463-2937 [email protected]