GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North...

40
GRIPTION ® TF Acetabular Revision Solutions DESIGN RATIONALE / SURGICAL TECHNIQUE

Transcript of GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North...

Page 1: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

GRIPTION® TFAcetabular Revision Solutions

DESIGN RATIONALE / SURGICAL TECHNIQUE

Page 2: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique
Page 3: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique DePuy Synthes Joint Reconstruction 3

DESIGN RATIONALE

SURGICAL TECHNIQUE

ORDERING INFORMATION

TABLE OF CONTENTS

Introduction 6

System Overview 7

Advanced Material 10

Advanced Fixation 12

Increased Compatibility 17

Advanced Instrumentation 18

Key Bone Stock and Landmark Considerations 20

Acetabular Preparation 21

Implant Insertion 24

Implant Options 32

Screw Options 33

Instruments 35

Page 4: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

Advanced

InstrumentationAdvanced

Fixation

Advanced

Material

GRIPTION® TF Acetabular SystemFilling the gap in acetabular revision surgery

Page 5: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique
Page 6: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

DePuy Synthes Joint Reconstruction’s* GRIPTION® TF Acetabular Revision System is an innovative technology for addressing bone defects in complex acetabular revision surgery. It represents the latest advances in materials, fixation, and instrumentation technologies. Combined with other elements of the PINNACLE® Hip Solutions portfolio – including the leading acetabular shell system and advanced bearing options – the result is a potential winning solution to help restore motion for today’s revision patient.

INTRODUCTION

DESIGN RATIONALE

6 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 7: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

The GRIPTION® TF Augments are designed to act as a defect filling implant in the case of severe bone loss in the acetabulum.

Advanced geometry provides increased surface area for bone contact.

Screw holes engineered to maximize fixation capability. 5.5 mm locking or 5.0 mm non-locking screws can be utilized on the outer rim.

Screwhole cutaways designed to optimize fit with PINNACLE Shell System.

Proprietary TRUEBOND™ Locking Slot to help mechanically secure Augment to acetabular shell using a PINNACLE 6.5

mm Bone Screw. Additionally bone cement can be used along with the

screw for hybrid fixation, or cement only can be used. See pages 10 - 11 for

more information.

Tight radius inner diameter to achieve precise fit with shell.

AUGMENT

SYSTEM OVERVIEW

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 7

Page 8: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

SYSTEM OVERVIEW

The GRIPTION TF Buttress is designed to support the shell in a similar manner as the Augments. It is important to note the Buttress implant spans the defect in the acetabulum and must be cemented to the shell.

Tapered curved surface for ease of implantation

Screw holes for use with 5.5 mm locking/5.0 mm nonlocking screws

Screw holes for use with PINNACLE 6.5 mm Bone Screws.

Curved spherical radius to mate with Acetabular Shell

BUTTRESS

Neutral, left and right configurations available for different implant positioning

8 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 9: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

The GRIPTION TF Shim Implants are designed to mate with the Buttress via cement to raise the end of the Buttress when pelvic geometries require support.

Oversized holes for clearance of locking/non-locking screws

Available in 5, 10 and 15 degree configurations

SHIM

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 9

Page 10: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AdvancedInstrumentation

AdvancedFixation

AdvancedMaterial

1.02

1.00

0.98

0.96

0.94

0.92

0.90

0.88

0.86

0.84

0.82

0.04

0.02

0.0GRIPTION TF

Material1*Trabecular Metal™

Material2

Coefficient of Friction

*Note: The Coefficient of Friction for the GRIPTION TF Material is representative of the high end of the specification.

The GRIPTION TF Material is a completely porous structure made from commercially pure titanium. It provides a modulus of elasticity similar to bone, and a coefficient of friction that allows for initial scratch fit.

ADVANCED MATERIAL

11 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 11: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

Compressive Yield Strength

60

50

40

30

20

10

0GRIPTION TF

Material1Trabecular Metal™

Material3

MPa

20

15

10

5

0

GPa

GRIPTION TFMaterial1

Trabecular Metal™ Material3

Cortical5Bone

Cancellous4

Bone

Young’s Modulus Compressive Yield Strength

Competitive Comparison

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 11

Page 12: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AdvancedInstrumentation

AdvancedFixation

AdvancedMaterial

CEMENTED

ADVANCED FIXATION

Cemented

Note: The Buttress must always be cemented to the shell

11 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 13: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

Prior to the availability of the GRIPTION TF Augments, the only method of fixating the Augment to the shell was with bone cement. The introduction of the GRIPTION TF Augments allow surgeons to select between cementless, cemented, and hybrid options of Augment to shell fixation.

CEMENTED, CEMENTLESS,OR HYBRID FIXATION OPTIONS

* The TRUEBOND Cementless Technology and hybrid fixation is achieved using a 6.5 mm PINNACLE Bone Screw from the shell to the augment.

Cemented

TRUEBOND Cementless Technology*

Hybrid Fixation*

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 13

Page 14: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

GRIPTION TF Implants have the ability to use locking screws to fixate Augments and Buttresses to the host bone. The Locking Screw Mechanism helps prevent the screw from becoming loose and backing out of the implant. This helps eliminate the risk of compromising fixation as a result of screw migration. In addition, GRIPTION TF Augments allow surgeons to implant diverging locking screws for even stronger fixation to the host bone.

5.5 mm Locking Screws can be utilized in the inner diameter of the augment as well as on the outer rim as shown in the image.

When using with Buttresses, 5.5 mm Locking screws can be utilized in the proximal four screw holes of the Buttress.

Note: Locking Screws should not be placed in the Truebond Locking Slot of the Augment. The TRUEBOND Locking Slot is only compatible with a 6.5 mm PINNACLE Bone Screw.

LOCKING SCREW OPTION

ADVANCED FIXATION

11 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 15: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

SCREW PLACEMENT

5.0 mm non-locking screw or 5.5 mm polyaxial locking screw

5.5 mm polyaxial locking screwNote: On the 10 mm thick augments the two outside holes on the outer periphery are for Threaded Headed pin placement only. Do not place screws through these two holes.

6.5 mm PINNACLE Cancellous Bone Screw

5.5 mm Gription TF Locking or 5.0 mm Peripheral Non-Locking Screws

Oversized through-holes on the Shims allow for the 5.5 mm Gription TF

Locking or the 5.0 mm Peripheral Non-Locking Screws to pass through.

6.5 mm PINNACLE Bone Screws ONLY

Note: The 6.5 mm PINNACLE Bone Screw is only used in the event of Mechanical Screw Fixation of the Augment to the Cup. This screw will go from the PINNACLE Cup into the Augment TRUEBOND Slot.

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 11

Page 16: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

The option is also available for 5.0 mm PINNACLE Non-Locking Screws to be placed on the flat outer rim of the augment and the proximal four screw holes of the Buttress.

Note: Do not place PINNACLE Non-Locking Screws in the inner diameter screw holes of the Augment. The only time a screw is used with the TRUEBOND Locking Slot of the Augment is for mechanical fixation of the PINNACLE Cup to the GRIPTION TF Augment.

NON-LOCKING SCREW OPTION

ADVANCED FIXATION

16 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 17: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

100 series

Sector

Deep Profile Revision

INCREASED COMPATIBILITY

The DePuy Synthes Joint Reconstruction GRIPTION TF Augments are compatible with the PINNACLE Hip Solutions Acetabular System. The PINNACLE Hip Solutions portfolio provides the largest selection of advanced bearing technologies. With more implant designs and choices than any competitive system, surgeons won’t have to compromise when meeting the individual needs of patients.

Multi-Hole

Standard Profile Revision

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 17

Page 18: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AdvancedInstrumentation

AdvancedFixation

AdvancedMaterial

The GRIPTION TF Revision System allows surgeons to select two methods of preparing the acetabular bone with their choice of modular or finishing rasps.

The instruments for the GRIPTION TF System were designed to provide ease of use and consistency for the surgeon and OR team. The finishing rasps, modular rasps, and accompanying PINNACLE Cup Instrumentation allow for an increased conformity between the prepared bone and the implant.

ADVANCED INSTRUMENTATION

18 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 19: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

Finishing rasp

Half Shell Trial

Modular rasp

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 19

Page 20: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

RADIOGRAPHIC LANDMARKS

BONE STOCK CONSIDERATIONSCompletely supportive acetabulum: PINNACLE Hip Solutions Shell

Partially supportive acetabulum: PINNACLE Hip Solutions Shell with GRIPTION TF Augments

Non-Supportive acetabulum: PINNACLE Hip Solutions Shell with possible need for Augment, Buttress or Cage

Radiographic landmarks can be helpful in assessing the acetabular bone stock. It can also be useful to order a CT scan of the area with a metal suppression technique. A CT scan will often indicate significantly more lysis than what is apparent on plain radiographs, and can also aid in determining pelvic discontinuities or loss of structural bone.

ANATOMIC LANDMARKS

1. Acetabular teardrop – integrity of medial wall and inferior portion of anterior and posterior column

2. Kohler’s line – integrity of medial wall and superior anterior column

3. Ischial lysis – integrity of posterior wall and posterior column

Using the standard DePuy Synthes Joint Reconstruction PINNACLE Acetabular Shell Templates, the surgeon can determine the approximate size of the revision shell that may be required, including the possibility of jumbo shells (>66 mm diameter), deep profile shells, or acetabular Augments. Assessing the acetabular bone stock is of great importance in helping the surgeon to anticipate the possible structural defects that may be encountered during the surgery.

PRE-OPERATIVE PLANNING AND TEMPLATINGShell OD Augment ID Buttress ID

50, 52 50 mm 56 mm

54, 56 54 mm 56mm

58, 60 58 mm 62mm

62, 64 62 mm 62 mm

66, 68 66 mm 68 mm

70, 72 70 mm 68mm

GRIPTION TF SURGICAL TECHNIQUE

11 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 21: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AUGMENT ACETABULAR PREPARATIONOnce the acetabulum has been exposed and evaluated, preparation for the acetabular construct can begin. Start by reaming the acetabulum with an undersized reamer at a level that will restore the appropriate center of rotation. Ream concentrically with progressively larger reamers – maintaining appropriate opening abduction and anteversion. Reaming should stop when adequate rim contact (this is dictated by the anterior posterior dimensions of the socket) has been obtained excluding the defect region.

At this point, the surgeon has 2 options for preparing the acetabular defect to accept the GRIPTION TF Augment:

• Finishing Rasp (most utilized option)

• Modular Rasp

Tip: Occasionally there could be sclerotic bone hindering seating of rasp. If this is the case a high speed burr could be utilized to finalize.

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 11

Page 22: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

Tip: Use the threaded headed pins to stabilize the augment trial.

GRIPTION TF SURGICAL TECHNIQUE

FINISHING RASP TECHNIQUE

Once the acetabular cavity has been prepared, place the shell trial into the prepared bed at the correct center of rotation.

Choose the appropriately sized finishing rasp that corresponds with your PINNACLE Shell. Start preparing the acetabular defect by keeping the inside diameter of the finishing rasp against the outer surface of the acetabular trial. Rasps should only be utilized over the shell trial and not over the final shell implant.

Note: Take care to confirm that the connections for the Strike Plate-Handle and Power Adapter-Handle have been fully engaged. The button feature will return to it’s original height and an audible clicking noise will be apparent. Rasps can be used with Stryker® Reciprocating Power.

Advance the rasp slowly until the desired seating level is obtained. The rasp sizes directly match the corresponding augment trial and final implant. These rasps can be used to judge the seating of the actual implant. If it appears that there is not intimate bone contact with the rasp, increasing to the next thickness of rasp may be necessary, repeating the steps above until adequate bone contact has been obtained. Once the defect has been prepared satisfactorily, tap the appropriate GRIPTION TF Augment Trial into place.

If the trial is stable, then the defect is appropriately prepared. If adequate bone contact is not obtained, or the trial is not stable, further preparation with larger rasps may be needed.

Tip: For improved stability when rasping, use the adjustable handle (2217-01-500). Further stability may be achieved by using screws or headed drill pins in the trial shell. Placement of the screws or headed drill pins should be considered. Select holes so that the screws or pins will lie within the safe quadrant. The safe quadrant is defined by two lines from the anterior-inferior iliac spine through the center of the acetabulum and posterior by a line from the sciatic notch to the center of the acetabulum.

AUGMENT ACETABULAR PREPARATION

11 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 23: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

MODULAR RASP TECHNIQUE

Once the acetabular cavity has been prepared, utilize the half shell trial that is undersized by 1 mm from the last reamer or acetabular trial that was used. Place the trial in the prepared acetabular cavity at the correct center of rotation. Attach the modular rasp to the dovetail of the trial and advance the construct so that the rasp will prepare the defect appropriately. Starting with the smallest size rasp, prepare the defect utilizing progressively larger rasps until the defect has been satisfactorily prepared to accept the appropriate size Augment. Rasps can be used on power with the Stryker Rasping Power Adaptor (2217-01-517), or can be used by hand utilizing the Rasping Strike Plate (2217-01-516). Remove the half shell trial and insert the appropriate full hemispherical acetabular trial. The GRIPTION TF Augment Trial can now be placed into the defect and can be tapped into place. If the trial is stable, the defect is appropriately prepared. If adequate bone contact is not realized or the trial is not stable, then further preparation with larger rasps may be needed.

Once appropriate stability has been obtained for the Augment trial, the definitive Augment is ready to be placed.

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 13

Page 24: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AUGMENT INSERTIONOnce the acetabulum and acetabular defect have been prepared to accept the acetabular shell and augment, the surgeon can decide to first place the acetabular shell and then the augment, or first place the augment and then the shell. Placing the acetabular shell prior to the augment limits access to the screw holes on the inner diameter of the augment. In addition, at the time of insertion of the shell and Augment, the surgeon should decide whether cement fixation or mechanical fixation will be utilized to attach the Augment to the acetabular shell.

ACETABULAR SHELL-FIRST TECHNIQUE

After preparation of the acetabulum and accompanying defect has been completed, insert the acetabular shell in accordance with the PINNACLE Acetabular Shell System technique.

Note: Acetabular shells should be placed at a targeted 35-45 degrees of abduction and 15-20 degrees of anteversion based on individual patient needs and pre-op planning.

Use an ARD whose center aligns with the center of a screw hole. May be helpful to mark this ARD with a pen.

The augment can be marked with a line in the center to represent the center of the slot

Align the Anti -Rotational Device (ARD) with the center line of the augment while impacting the shell, and the slot will line up with the screw hole.

GRIPTION TF SURGICAL TECHNIQUE

11 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 25: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

ACETABULAR SHELL-FIRST TECHNIQUE (CONTINUED)

A 6.5 mm PINNACLE Bone Screw may be placed at this point. The surgeon should pay close attention to any shift in position of the shell that may occur secondary to placing and tightening down the screws. If the shell requires placement of the Augment to provide stability of the construct, tightening the screws before placing the Augment may shift the shell slightly. This may cause difficulty in placing the Augment if the acetabular defect has been prepared in a precise manner. If a shift in position of the acetabular shell is noted, the screws should be backed out slightly to allow the appropriate placement of the Augment and then re-tighten. If the shell is stable without initial screw fixation the 6.5 mm PINNACLE Bone Screw can be placed after the Augment has been inserted.

Drill Bits Screws

3.8 drill bit 6.5 mm Pinnacle Bone Screws

5.5 mm Locking Screws

3.2 drill bit 5.0 mm Non-Locking Screws

Once the acetabular shell is in place, if Cemented or Hybrid fixation is desired, place a bead of doughy cement on the outer surface of the shell prior to placing the Augment.

The Augment inserter tip should be placed on the flat surface of the Augment in the two center holes. The Augment can then be tapped into place behind the acetabular shell and into the prepared defect.

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 11

Page 26: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

ACETABULAR SHELL-FIRST TECHNIQUE (CONTINUED)

Screw fixation of the Augment can then be performed using the 5.5 mm locking or 5.0 mm non-locking screws. The Threaded Headed pins can be used to help stabilize the Augment during screw insertion if necessary.

Alternatively, the surgical assistant can stabilize the Augment with the inserter tip until screw fixation is obtained.

Cementless Option:

If TRUEBOND Cementless Technology fixation is desired, a standard PINNACLE 6.5 mm Bone Screw can be placed through the shell and fixation slot of the Augment. Special care should be taken to ensure that the head of the screw is fully seated within the acetabular shell.

Tip: • Care should be taken to ensure that the PINNACLE Screw used to attach the augment to the cup does not extend beyond the augment into bone. If the screw extends past the augment and into bone then there is the potential to create a gap between the shell and augment.

• Use the 3.8 drill bit for the 6.5 mm cancellous screws.

• Use the 3.8 drill bit for the 5.5 mm locking screws.

• Use the 3.2 drill bit (in the PINNACLE Revision System) for the 5.0 mm non-locking screws.

AUGMENT INSERTION

GRIPTION TF SURGICAL TECHNIQUE

16 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 27: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AUGMENT-FIRST TECHNIQUE

Following preparation of the acetabulum and accompanying defect, place the acetabular augment. Utilize the 90-degree inserter tip on the inside diameter of the Augment. The Augment can now be impacted into the defect or held in place with the inserter. Insert the threaded, headed pins through the holes in the flat face of the Augment to provide provisional fixation.

Screw fixation utilizing either 5.5 mm locking or 5.0 mm non-locking screws can now be performed. On the inside diameter of the Augment, only 5.5 mm locking screws can be utilized. Special care should be taken to ensure that the screw heads are fully seated and flush when utilizing the inner diameter fixation holes.

Note: • Do not attempt screw fixation through the center TRUEBOND Slot directly into bone.

• Do not drill into the augment to alter the shape or add additional screw holes.

• Do not attempt screw fixation in the outer periphery of the 10 mm thick augments. These are to be used for pin fixation only.

• Utilize either the straight or 45- degree drills on the inner diameter screw holes

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 17

Page 28: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

AUGMENT-FIRST TECHNIQUE (CONTINUED)

Cemented Option:

If the cemented fixation option is desired, a bead of doughy cement can now be placed on the inner diameter of the Augment and the acetabular shell can be impacted in the standard fashion. A 6.5 mm PINNACLE Bone Screw can now be used for acetabular shell fixation.

Hybrid Option:

If the hybrid fixation option will be utilized, the shell should be carefully positioned during impaction so that the fixation slot of the Augment lines up with an appropriate dome hole in the Acetabular Shell. The shell should be impacted utilizing the standard PINNACLE Acetabular Shell surgical technique. Once the shell is in position, screw fixation of the shell can be carried out. An additional 6.5 mm PINNACLE Bone Screw may be placed through the appropriate dome hole in the shell and through the fixation slot in the Augment. Special care should be taken to ensure that this screw head is fully seated within the inside diameter of the shell.

Tip: Bone wax on the tip of the inserter may assist holding the Augment on the inserter device (optional).

GRIPTION TF SURGICAL TECHNIQUE

AUGMENT INSERTION

18 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 29: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

In some cases, the acetabular defect will require a Buttress rather than an Augment in order to provide the appropriate stabilization of the construct. Once this has been determined, exposure of the iliac wing is required. Care should be taken to avoid disruption of the vascular structures within this area. In most cases a large elevator can be used to subperiosteally elevate the abductor musculature from the ilium to adequately allow placement of the Buttress in the correct position. In cases where exposure is difficult, it may be necessary to perform some type of trochanteric osteotomy, trochanteric slide, or a variant thereof, to aid in exposure of the iliac wing in the supra-acetabular area.

Once exposure is achieved, similar to the acetabular preparation of the Augment, the acetabulum should be reamed to the desired diameter. At this point, if the defect needs additional preparation for the Buttress Implant, utilize the GRIPTION TF Rasping System in the same manner as the Augments, or a high speed burr. Care should be taken to ensure only necessary bone is removed to prepare the cavity for the Buttress. Next, a hemispherical cup trial should be inserted, to trial alongside the corresponding Buttress trial. Different Buttress trials should be evaluated to see which orientation (Left, Right or Neutral) can best address the defect.

Since pelvic geometries can differ, Shims may be required to help position the construct as well as raise and angulate the Buttress. In the event a Shim is required, trial this alongside the appropriate Buttress. The Shim trials come in three angle options, a 5°, 10°, and 15° and can be oriented in 90 degree increments, which snaps onto the Buttress trial for ease of use.

Tip: Select screws that are longer than the combined thickness of the Buttress and Shim. Care should be taken to not perforate the pelvis.

BUTTRESS AND SHIM INSERTION

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 19

Page 30: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

BUTTRESS AND SHIM INSERTION

GRIPTION TF SURGICAL TECHNIQUE

ACETABULAR SHELL-FIRST TECHNIQUE

Once the appropriate position of the Buttress has been determined, the surgeon has the choice of which to implant first: The PINNACLE Shell or the Buttress. If the acetabular shell is placed first, it is impacted in the standard fashion and supplemental screw fixation is utilized at this time. If only a Buttress is to be used, a bead of cement should now be placed on the surface of the PINNACLE Shell which will contact the inner diameter of the Buttress. Supplemental screw fixation with the GRIPTION TF Locking Screws, 5.0 mm Peripheral Screws and/or the PINNACLE Bone Screws should be used at this time. It is recommended to use at least 2 screws if possible for stabilization.

In the event a Shim is also used, after impacting the PINNACLE Shell, cement the Shim and the Buttress together outside the wound. Care should be taken to ensure there is no cement left in between the screw holes, and that the Shim is positioned in the same manner as when trialing. Once the cement has cured, continue the same steps as mentioned above, by adding a bead of cement to the PINNACLE Shell to insert the Buttress and/or Shim.

Note: In the event a Shim is used, cement the flat side which has the etching, to the underside of the Buttress.

The Buttress construct can then be placed and held in position with the knurled, threaded guide pins while screw fixation is being performed, or alternately it can be held manually. PINNACLE 6.5 mm Bone Screws are used in the two distal holes of the Buttress, closest to the inner diameter. These screw holes allow for slight divergent placement to aid in stability and fixation. GRIPTION TF 5.5 mm Locking or the 5.0 mm Peripheral Non-Locking Screws can be used in the proximal four holes of the Buttress. Care should be taken when inserting the screws into the Buttress plate to avoid potential neurovascular injury.

Note: It is recommended to use at least two screws out of the six possible screw holes if bone allows. See the Screw Options Chart in this Surgical Technique for guidance.

31 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 31: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

BUTTRESS AND SHIM FIRST TECHNIQUE

After the acetabulum is reamed to the desired diameter place the corresponding acetabular shell trial in place. Next, trial the defect using the Buttress and/or Shim trials to best address the defect, in a similar manner described above. At this point, secure the acetabular trial in place using either the angled handle along with an assistant to hold it, or angling the headed pins to keep the shell trial in place.

To insert the Buttress implant based on the trial that has been completed, slide this into place against the shell trial, and secure the implant with the headed threaded pins while supplemental screw fixation is taking place. Care should be taken when inserting screws to avoid neurovascular injury.

Once the Buttress is secure, remove the acetabular shell trial and add a bead of cement to the inner diameter of the Buttress. Insert the final PINNACLE Shell into the acetabulum and utilize screw fixation at this time. Care should be taken to ensure the Buttress construct has not moved once the PINNACLE Cup has been inserted.

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 31

Page 32: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

IMPLANT OPTIONSGRIPTION TF AUGMENTS

1217-10-150 GRIPTION TF Augment size 50/52 x 10

1217-10-154 GRIPTION TF Augment size 54/56 x 10

1217-10-158 GRIPTION TF Augment size 58/60 x 10

1217-10-162 GRIPTION TF Augment size 62/64 x 10

1217-10-166 GRIPTION TF Augment size 66/68 x 10

1217-10-170 GRIPTION TF Augment size 70/72 x 10

1217-15-250 GRIPTION TF Augment size 50/52 x 15

1217-15-254 GRIPTION TF Augment size 54/56 x 15

1217-15-258 GRIPTION TF Augment size 58/60 x 15

1217-15-262 GRIPTION TF Augment size 62/64 x 15

1217-15-266 GRIPTION TF Augment size 66/68 x 15

1217-15-270 GRIPTION TF Augment size 70/72 x 15

1217-20-350 GRIPTION TF Augment size 50/52 x 20

1217-20-354 GRIPTION TF Augment size 54/56 x 20

1217-20-358 GRIPTION TF Augment size 58/60 x 20

1217-20-362 GRIPTION TF Augment size 62/64 x 20

1217-20-366 GRIPTION TF Augment size 66/68 x 20

1217-20-370 GRIPTION TF Augment size 70/72 x 20

1217-30-450 GRIPTION TF Augment size 50/52 x 30

1217-30-454 GRIPTION TF Augment size 54/56 x 30

1217-30-458 GRIPTION TF Augment size 58/60 x 30

1217-30-462 GRIPTION TF Augment size 62/64 x 30

1217-30-466 GRIPTION TF Augment size 66/68 x 30

1217-30-470 GRIPTION TF Augment size 70/72 x 30

GRIPTION TF BUTTRESSES

1217-00-156 GRIPTION TF Revision Buttress 56 Neutral

1217-00-256 GRIPTION TF Revision Buttress 56 Left

1217-00-356 GRIPTION TF Revision Buttress 56 Right

1217-00-162 GRIPTION TF Revision Buttress 62 Neutral

1217-00-262 GRIPTION TF Revision Buttress 62 Left

1217-00-362 GRIPTION TF Revision Buttress 62 Right

1217-00-168 GRIPTION TF Revision Buttress 68 Neutral

1217-00-268 GRIPTION TF Revision Buttress 68 Left

1217-00-368 GRIPTION TF Revision Buttress 68 Right

GRIPTION TF SHIMS

1217-00-105 GRIPTION TF Revision Shim, 5 Degree

1217-00-110 GRIPTION TF Revision Shim, 10 Degree

1217-00-115 GRIPTION TF Revision Shim, 15 Degree

ORDERING INFORMATION

31 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

Page 33: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

MECHANICAL SCREW FIXATION OPTIONS

6.5 mm PINNACLE Cancellous Screws (Sterile)

1217-08-500 PINNACLE Bone Screw 6.5 mm x 8mm

1217-15-500 PINNACLE Bone Screw 6.5 mm x 15 mm

1217-20-500 PINNACLE Bone Screw 6.5 mm x 20 mm

1217-25-500 PINNACLE Bone Screw 6.5 mm x 25 mm

1217-30-500 PINNACLE Bone Screw 6.5 mm x 30 mm

AUGMENT SCREW OPTIONS

5.5 mm GRIPTION TF Locking Screws (Sterile)

1217-25-800 GRIPTION TF Locking Screw 5.5 mm x 25 mm

1217-30-800 GRIPTION TF Locking Screw 5.5 mm x 30 mm

1217-35-800 GRIPTION TF Locking Screw 5.5 mm x 35 mm

1217-40-800 GRIPTION TF Locking Screw 5.5 mm x 40 mm

1217-45-800 GRIPTION TF Locking Screw 5.5 mm x 45 mm

1217-50-800 GRIPTION TF Locking Screw 5.5 mm x 50 mm

1217-55-800 GRIPTION TF Locking Screw 5.5 mm x 55 mm

1217-60-800 GRIPTION TF Locking Screw 5.5 mm x 60 mm

1217-65-800 GRIPTION TF Locking Screw 5.5 mm x 65 mm

1217-70-800 GRIPTION TF Locking Screw 5.5 mm x 70 mm

5.0 mm Cancellous Screws (Sterile)

1257-25-000 Cancellous Non-locking Screw 5.0 mm x 25 mm

1257-25-000 Cancellous Non-locking Screw 5.0 mm x 30 mm

1257-25-000 Cancellous Non-locking Screw 5.0 mm x 35 mm

1257-25-000 Cancellous Non-locking Screw 5.0 mm x 40 mm

1257-25-000 Cancellous Non-locking Screw 5.0 mm x 45 mm

1257-50-000 Cancellous Non-locking Screw 5.0 mm x 50 mm

1257-55-000 Cancellous Non-locking Screw 5.0 mm x 55 mm

1257-60-000 Cancellous Non-locking Screw 5.0 mm x 60 mm

1257-65-000 Cancellous Non-locking Screw 5.0 mm x 65 mm

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 33

SCREW OPTIONS

Page 34: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

BUTTRESS & SHIM SCREW OPTIONS

5.5 mm Locking Screw Options (Sterile)

1217-14-800 GRIPTION TF 5.5 mm x 14 mm Locking Screw

1217-16-800 GRIPTION TF 5.5 mm x 16 mm Locking Screw

1217-18-800 GRIPTION TF 5.5 mm x 18 mm Locking Screw

1217-20-800 GRIPTION TF 5.5 mm x 20 mm Locking Screw

1217-22-800 GRIPTION TF 5.5 mm x 22 mm Locking Screw

1217-24-800 GRIPTION TF 5.5 mm x 24 mm Locking Screw

1217-25-800 GRIPTION TF 5.5 mm x 25 mm Locking Screw

1217-30-800 GRIPTION TF 5.5 mm x 30 mm Locking Screw

5.0 mm Non-Locking Screw Options (Sterile)

1257-25-000 5.0 mm x 25 mm Tapered Non-locking Screw

1257-30-000 5.0 mm x 30 mm Tapered Non-locking Screw

MECHANICAL SCREW FIXATION OPTIONS: BUTTRESSES ONLY

6.5 mm PINNACLE Cancellous Screw Options (Sterile)

1217-08-500 PINNACLE Cancellous Bone Screw 6.5 mm x 8 mm

1217-15-500 PINNACLE Cancellous Bone Screw 6.5 mm x 15 mm

1217-20-500 PINNACLE Cancellous Bone Screw 6.5 mm x 20 mm

1217-25-500 PINNACLE Cancellous Bone Screw 6.5 mm x 25 mm

1217-30-500 PINNACLE Cancellous Bone Screw 6.5 mm x 30 mm

31 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

SCREW OPTIONS

ORDERING INFORMATION

Page 35: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

INSTRUMENTSCASE ONE

Trial Case – Top Tray

2217-10-150 GRIPTION TF Augment size 50/52x10 Trial

2217-10-154 GRIPTION TF Augment size 54/56x10 Trial

2217-10-158 GRIPTION TF Augment size 58/60x10 Trial

2217-10-162 GRIPTION TF Augment size 62/64x10 Trial

2217-10-166 GRIPTION TF Augment size 66/68x10 Trial

2217-10-170 GRIPTION TF Augment size 70/72x10 Trial

2217-15-250 GRIPTION TF Augment size 50/52x15 Trial

2217-15-254 GRIPTION TF Augment size 54/56x15 Trial

2217-15-258 GRIPTION TF Augment size 58/60x15 Trial

2217-15-262 GRIPTION TF Augment size 62/64x15 Trial

2217-15-266 GRIPTION TF Augment size 66/68x15 Trial

2217-15-270 GRIPTION TF Augment size 70/72x15 Trial

2217-20-350 GRIPTION TF Augment size 50/52x20 Trial

2217-20-354 GRIPTION TF Augment size 54/56x20 Trial

2217-20-358 GRIPTION TF Augment size 58/60x20 Trial

2217-20-362 GRIPTION TF Augment size 62/64x20 Trial

2217-20-366 GRIPTION TF Augment size 66/68x20 Trial

2217-20-370 GRIPTION TF Augment size 70/72x20 Trial

2217-30-450 GRIPTION TF Augment size 50/52x30 Trial

2217-30-454 GRIPTION TF Augment size 54/56x30 Trial

2217-30-458 GRIPTION TF Augment size 58/60x30 Trial

2217-30-462 GRIPTION TF Augment size 62/64x30 Trial

2217-30-466 GRIPTION TF Augment size 66/68x30 Trial

2217-30-470 GRIPTION TF Augment size 70/72x30 Trial

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 31

Page 36: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

CASE ONE

Trial Case – Bottom Tray

2217-01-517 Rasping Power Adaptor

2217-01-516 Rasping Strike Plate

2217-01-503 Augment Rasping Handle

2217-01-500 Augment Adjustable Handles

INSTRUMENTS

36 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

ORDERING INFORMATION

Page 37: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

CASE ONE

Trial Case – Middle Tray – GRIPTION TF Buttress and Shim Trials

2217-00-156 GRIPTION TF Buttress 56 Neutral Trial

2217-00-256 GRIPTION TF Buttress 56 Left Trial

2217-00-356 GRIPTION TF Buttress 56 Right Trial

2217-00-162 GRIPTION TF Buttress 62 Neutral Trial

2217-00-262 GRIPTION TF Buttress 62 Left Trial

2217-00-362 GRIPTION TF Buttress 62 Right Trial

2217-00-168 GRIPTION TF Buttress 68 Neutral Trial

2217-00-268 GRIPTION TF Buttress 68 Left Trial

2217-00-368 GRIPTION TF Buttress 68 Right Trial

2217-00-105 GRIPTION TF Shim Trial 5 Degree

2217-00-110 GRIPTION TF Shim Trial 10 Degree

2217-00-115 GRIPTION TF Shim Trial 15 Degree

2366-83-000 45-Degree Angle Drill

2274-36-000 DURALOC Depth Gauge

2274-09-000 DURALOC Drill Bit 3.8 Dia 10 mm

2366-84-000 3.8 mm Drill Bit 25 mm

2274-12-000 DURALOC Drill Bit 3.8 Dia 40 mm

2366-85-000 3.8 mm Drill Bit 50 mm

2217-01-518 Headed Drill PINNACLE 15 mm

2217-01-519 Headed Drill PINNACLE 20 mm

2217-01-505 Headed Drill PINNACLE 30 mm

2217-01-506 Headed Drill PINNACLE 35 mm

2217-01-507 Headed Drill PINNACLE 40 mm

2217-01-508 Headed Drill PINNACLE 45 mm

2217-01-509 Headed Drill PINNACLE 50 mm

9505-02-071 HP Power PINNACLE Driver

2217-01-501 Augment Insert Tip Top

2217-01-502 Augment Insert Tip 90 Degree

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 37

Page 38: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

CASE TWO

Finishing Rasp Case

2217-10-550 Augment Finishing Rasp 50 x 10

2217-10-554 Augment Finishing Rasp 54 x 10

2217-10-558 Augment Finishing Rasp 58 x 10

2217-10-562 Augment Finishing Rasp 62 x 10

2217-10-566 Augment Finishing Rasp 66 x 10

2217-10-570 Augment Finishing Rasp 70 x 10

2217-15-550 Augment Finishing Rasp 50 x 15

2217-15-554 Augment Finishing Rasp 54 x 15

2217-15-558 Augment Finishing Rasp 58 x 15

2217-15-562 Augment Finishing Rasp 62 x 15

2217-15-566 Augment Finishing Rasp 66 x 15

2217-15-570 Augment Finishing Rasp 70 x 15

2217-20-550 Augment Finishing Rasp 50 x 20

2217-20-554 Augment Finishing Rasp 54 x 20

2217-20-558 Augment Finishing Rasp 58 x 20

2217-20-562 Augment Finishing Rasp 62 x 20

2217-20-566 Augment Finishing Rasp 66 x 20

2217-20-570 Augment Finishing Rasp 70 x 20

2217-30-550 Agument Finishing Rasp 50 x 30

2217-30-554 Agument Finishing Rasp 54 x 30

2217-30-558 Agument Finishing Rasp 58 x 30

2217-30-562 Agument Finishing Rasp 62 x 30

2217-30-566 Agument Finishing Rasp 66 x 30

2217-30-570 Agument Finishing Rasp 70 x 30

INSTRUMENTS

38 DePuy Synthes Joint Reconstruction GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique

ORDERING INFORMATION

Page 39: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

CASE THREE

Modular Rasp Case

2217-01-550 Augment Modular Rasp 50/52

2217-01-554 Augment Modular Rasp 54/56

2217-01-558 Augment Modular Rasp 58/60

2217-01-562 Augment Modular Rasp 62/64

2217-01-566 Augment Modular Rasp 66/68

2217-01-570 Augment Modular Rasp 70/72

2217-01-649 Half Shell Trial 49 mm

2217-01-653 Half Shell Trial 53 mm

2217-01-657 Half Shell Trial 57 mm

2217-01-661 Half Shell Trial 61 mm

2217-01-665 Half Shell Trial 65 mm

2217-01-669 Half Shell Trial 69 mm

2217-01-580 Augment Rasp +5 mm Offset

2217-01-582 Augment Rasp +10 mm Offset

2217-01-584 Augment Rasp +20 mm Offset

GRIPTION® TF Acetabular Revision Solutions Design Rationale / Surgical Technique DePuy Synthes Joint Reconstruction 39

Page 40: GRIPTION TF - synthes.vo.llnwd.netsynthes.vo.llnwd.net/o16/LLNWMB8/US Mobile/Synthes North America... · GRIPTION® TF Acetabular Revision Solutions Design Rationale/Surgical Technique

REFERENCES1. Data on file, DePuy Orthopaedics, Inc, Warsaw, IN

2. Zhang Y, Ahn PB, Fitzpatrick DC, Heiner AD, Poggie RA, Brown TD. “Interfacial frictional behavior: cancellous bone, cortical bone, and a novel porous tantalum biomaterial.” J Musculoskel Res. 1999;3(4):245-251.

3. Zardiackas LD, Parsell DE, Dillon LD, Mitchell DW, Nunnery LA, Poggie R. “Structure, Metallurgy, and Mechanical Properties of a Porous Tantalum Foam.“ School of Dentistry/Biomaterials, Univer-sity of Mississippi Medical Center, 2000; 180-187

4. Sevilla P, Aparicio C, Planell JA, Gil FG. “Comparison of the mechanical properties between tantalum and nickel-titanium foams implant materials for bone ingrowth applications.“ J. Alloys and Compouds 439 (2007) 67-73.

5. Reilly, DT, Burstein, AH, Frankel, VH, “The elastic modulus for bone”, J. Biomechanics, V7, pp 271-275, 1974

DePuy Orthopaedics, Inc.700 Orthopaedic DriveWarsaw, IN 46582T. +1 (800) 366-8143

www.depuysynthes.com

Limited Warranty and Disclaimer: DePuy Synthes Joint Reconstruction products are sold with a limited warranty to the original purchaser against defects in workmanship and materials. Any other express or implied warranties, including warranties of merchantability or fitness, are hereby disclaimed.

WARNING: In the USA, this product has labeling limitations. See package insert for complete information.

CAUTION: USA Law restricts these devices to sale by or on the order of a physician.

Not all products are currently available in all markets.

The third party trademarks used herein are the trademarks of their respective owners.

*DePuy Synthes Joint Reconstruction is a division of DePuy Orthopaedics, Inc.© DePuy Synthes 2015. All rights reserved. DSUS/JRC/1014/0488(1) 02/15