GREY RIVER, VIC, 3234

14
Geoff & Linda Andrew 1 Great Ocean Road GREY RIVER, VIC, 3234 CORRUGATED COLORBOND WALL COLOUR: WALLABY CORRUGATED COLORBOND ROOF COLOUR: MONUMENT JAMES HARDIE LINEA BOARD COLOUR: HAYMES WILDERNESS Cover Page General Notes A1.01 3D Views A1.02 Site Plan - Existing A1.03 Site Plan - Proposed A1.04 Site Rescode Plan A1.05 Shadows A1.06 Set Out Plan A1.07 Site Cut A1.08 Ground Floor Plan A2.01 First Floor Plan A2.02 Elevations A2.03 Elevations A2.04 Roof Plan A2.05

Transcript of GREY RIVER, VIC, 3234

Page 1: GREY RIVER, VIC, 3234

Geoff & Linda Andrew1 Great Ocean RoadGREY RIVER, VIC, 3234

CORRUGATED COLORBONDWALL COLOUR: WALLABY

CORRUGATED COLORBONDROOF COLOUR: MONUMENT

JAMES HARDIE LINEA BOARDCOLOUR: HAYMES WILDERNESS

Cover PageGeneral Notes A1.013D Views A1.02Site Plan - Existing A1.03Site Plan - Proposed A1.04Site Rescode Plan A1.05Shadows A1.06Set Out Plan A1.07Site Cut A1.08

Ground Floor Plan A2.01First Floor Plan A2.02Elevations A2.03Elevations A2.04Roof Plan A2.05

Page 2: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

Custom

JOB ADDRESS1 Great Ocean Road

GREY RIVER, VIC, 3234

Page No: A1. 1

1:200Scale:

Drawn By:NMDate Created: 27/04/20

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS.

COPYRIGHT ©

THIS IS THE SOLE PROPERTY OF P.J.SCOTT HOMES AND

MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

Geoff & Linda Andrew

CLIENTS

Date Modified: 22/09/21Date Issued: 22/09/21

GENERAL NOTES

V1:Version Changes

BAL-29SUBFLOORSUPPORTS

Enclosure by external wall or by steel, bronze or aluminium mesh. Non-combustible or naturally fire resistant timber supports where the subfloor is unenclosed

FLOORS

EXTERNAL WALLS

EXTERNALWINDOWS

EXTERNAL DOORS

ROOFS

VERANDASDECKS ETC.

Concrete slab on ground or enclosure by external wall, metal mesh as above or flooring less than 400mm above ground level to be non combustible, naturally fire resistant timber or protected on the underside with sarking or mineral wool insulation

Non-combustible material (masonary, brickveneer, mud brick, aerated concrete, concrete), timber frame, steel framed walls sarked on the outside and clad with 6mm fibre cement sheeting or steel sheeting or bushfire resistant timber

5mm toughened glass with openable portion screened and frame of metal or metal reinforced PVC-U, or bushfire resistant timber and portion within 400mm of ground, deck etc. screened

Screened with steel, bronze or aluminium mesh or non-combustible or 35mm solid timber for 400mm above threshold, metal or bushfire resistant timber frame tight - fitting with weather strips at base

Non-combustible covering, Roof/Wall junction sealed. Openings fitted with non-combustible ember guards. Roof to be fully sarked

Enclosed sub floor space or non-combustible or bushfire resistsnt timber supports. Decking to be non-combustible or bushfire resisting timber

These plans have been prepared for the exclusive use by the client of P.J.Scott Homes ("The Designer") for the purpose expressly notifed to the Designer. Any other person who uses or relies on these plans without the Designers written consent does so at their own risk and no responsibility is accepted by the Designer for such use and/or reliance.

All materials and work practices shall comply with, but not limited to the building interim Regulations 2017, National Construction Code Series 2016 Building Code of Australia Vol 2 and all relevant current Australian Standards (as amened ) referred to therein.Unless otherwise specified, the term BCA shall refer to National Construction Code Series 2016 Building Code of Australia Volume 2.All materials and construction practice shall meet the performance of the BCA. where a performance solution is proposed then, prior to implementation or installation, it first must be assessed and approved by relevant Building Surveyor as meeting the performance requirements of the BCA.

Waterproofing of wet areas, being bathrooms, showers, shower rooms, laundries, sanitary compartments and the like shall be provided in accordance with AS 3740-2010: Waterproofing of Domestic Wet Areas.

Step Sizes (other than for spiral stairs)to be - Risers (R) 190mm Maximum and 115mm Minimum - Going (G) 355mm Maximum and 240mm Minimum - 2R + 1G = 700mm Maximum and 550mm Minimum - with less than 125mm gap between open treads.

All treads, ladings and the like to have a slip-resistance classification of P3 or R10 for dry surface conditions and P4 or R11 foe wet surface conditions, or a nosing strip with a slip-resistance classification of P3 for dry surface conditions and P4 for wet surface conditions

Provide barriers where change in level exceeds 1000mm above the surface beneath landings, ramps and/or treads. Barriers (other than tensioned wire barriers) to be - 1000mm min. above finished surface level of balconies, landings or the like, and - 865mm min. above finished surface level of stair nosing or ramp, and - vertical with less than 125mm gap between, and - any horizontal element within the barrier between 150mm and 760mm above the floor must not facilitate climbing where changes in level exceeds 4000mm above the surface beneath landings, ramps and/or treads.

Wire barrier construction to comply with NCC 2016 BCA Part 3.9.2.3 for class 1 and 10 Buildings and NCC 2016 BCA Volume 1 Part D2.16 for other Classes of Buildings.Top of handrails to be minimum 865mm vertically above stair nosing and floor surface of ramps.

All Stormwater to be taken to legal point of discharge to the Relevant Authorities approval. 90mm DIA. Class 6 UPVC stormwater line laid to a minimum grade of 1:100 and connected to legal point of stormwater discharge. Provide inspection openings at 9000mm C/C and at each change of direction. The cover to underground stormwater drains shall be not less - 100mm under soil - 50mm under paved or concrete areas - 100mm under unreinforced concrete or paved driveways - 75mm under reinforced concrete driveways.

The Builder and Subcontractor shall ensure that all stormwater drains, sewer pipes and the like are located at a sufficient distance from any buildings footing and/or slab edge beams so as to prevent general moisture penetration, dampness, weaking and undermining of any building and its footing system.

The Builder shall take all steps necessary to ensure the stability and general water tightness of all new and/or existing structures during all works.

Installation of all services shall comply with the respective supply authority requirements.

Provide an impervious substrate and select surface finish to floors within 1500mm of an unenclosed shower and same towalls at 1800mm above floors and 150mm above Bath,Sinks,Basins and Trough splash Backs and the like.

Building tie downs to be provided in accordance with AS1684-1999 for an assumed design gust wind speed/wind classification of N3(w41) (Subject to comfirmation on site by relevent building surveyor at first inspection) refer to AS1684 for construction requirements.

These Drawings shall be read in conjuction with all relevant structural and all other consultants drawings/ details and with any other written instructions issued in the course of the contract

These Drawings shall be read in conjuction with any Energy Rating (HERS) report and shall be constructed in accordance with the stamped plans endorsed by the accredited Thermal Performance Assessor without alteration

Where the building (excludes a detached Class 10) is located in a termite prone area the building is to be provided with a termite management system

Buiuldings in marine or other exposureenvironments shall have masony units , motar and all built in components and the like complying with the durability requirements of Table 4.1 of AS 4773.1-2010 Masonry in small buildings Part 1: Design

GLAZING: All glazing shall be carried out in accordance with AS1288. All glass sliding doors shall be clearly marked with safety markings. All framed glazing where the lowest sight line of the glazing panel is less than 500mm from the highest abutting finished floor level shall be grade A safety glazing material in accordance with AS1288-2006 except the ordinary annealed glass maybe used as follows:

Max Glazing Panel Area Standard Nominal Ticknessup to and including 0.1sqm 3mmup to and including 0.3sqm 4mmup to and including 2.0sqm 5mm

All Glazing to be standard nominal thick annealed unless listed otherwise in the window schedule.

Energy Rating Conducted by:FRATER ENERGY - VIC/BDAV/15/1682

Job No: 000000000

ENERGY RATING 6.0 Star

Structural Engineering Conducted by:ANDREW CHERUBIN & ASSOCIATES

Project No: 00-000PH No: 5261 4822

Insulation RequirementsAs per Energy Rating Report

Insulation Batts to ceiling - R4.1 Insulation Batts to External Walls - R2.5

and Garage internal wallsInsulation Batts to Internal Walls - N/A

Rooms

Insulation Batts Between Floors - N/A

Soil Classification Conducted by:P.J. YTTRUP & ASSOCIATES PTY LTD

Report No: 22652_G1 REV 2Soil: Class P - Problem Site

PH No: 03 52433 388

BUSHFIRE LEVEL LOW

Page 3: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. 3D VIEWS

CLIENTS:

JOB ADDRESS:

Custom Geoff & Linda Andrew1 Great Ocean Road

GREY RIVER, VIC, 3234Page No: A1. 2 Scale:

Drawn By:NMDate Created: 27/04/20Date Modified: 22/09/21Date Issued: 22/09/21

V1:Version Changes

Page 4: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. SITE EXISTING

CLIENTS:

JOB ADDRESS:

Custom Geoff & Linda Andrew1 Great Ocean Road

GREY RIVER, VIC, 3234Page No: A1. 3 Scale:

Drawn By:NMDate Created: 27/04/20Date Modified: 22/09/21Date Issued: 22/09/21

V1:Version Changes

Existing Building(To be Removed)

N

VACANT LAND(Rural Conservation Zone)

Page 5: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. SITE PROPOSED

CLIENTS:

JOB ADDRESS:

Custom Geoff & Linda Andrew1 Great Ocean Road

GREY RIVER, VIC, 3234Page No: A1. 4 Scale:

Drawn By:NMDate Created: 27/04/20Date Modified: 22/09/21Date Issued: 22/09/21

V1:Version Changes

45.95m

300°51'

47.82m

127°36'

16.0

9m

195°

20'

21.9

3m15

°20'

GRE

AT O

CEAN

RO

AD

15

16

17

18

19

20

N

4320

21

2500

5175

Approx. 3.4Km to Kennett River

VACANT LAND(Rural Conservation Zone)

EXISTING SINGLE STOREY

DWELLING

3000

PRIVATE OPEN SPACE8 x 10m² = 80m²

GARDEN AREA : 680m² - LOT SIZE 841m²ABOVE 650m² MUST BE > 35%GARDEN AREA = 680m² - 80.86% > 35%

CRUSHED ROCK DRIVEWAY

TBM TOP OF STAR PICKET

PROPOSED CONCRETE RETAINING WALLAPPROX. 600mm HIGHAPPROX. 3M LONG

191m² EFFLUENT AREA

Page 6: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. SITE RESCODE

CLIENTS:

JOB ADDRESS:

Custom Geoff & Linda Andrew1 Great Ocean Road

GREY RIVER, VIC, 3234Page No: A1. 5 Scale:

Drawn By:NMDate Created: 27/04/20Date Modified: 22/09/21Date Issued: 22/09/21

V1:Version Changes

45.95m

300°51'

47.82m

127°36'

16.0

9m

195°

20'

21.9

3m15

°20'

N

VACANT LAND(Rural Conservation Zone)

EXISTING SINGLE STOREY

DWELLING

1:200

GRE

AT O

CEAN

RO

AD

Site Boundary

Approx. 3.4Km to Kennett River

Garden Area : 680m² - Lot Size 841m²Above 650m² Must be greater then 35%Garden Area = 680m² - 80.86% > 35%

RESCODE SITE ANALYSIS

SITE AREA 841 m²RESIDENCE 152.27 m²

GARAGE 25.42 m²

DECK 46.16 m²GARDEN AREA 604 m² <35%

DRIVEWAY APPROX 90.23 m²

SITE COVERAGE 164.62 m² 19.69%PERMEABILITY 676.38 m² 80.31%

Page 7: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

Custom

JOB ADDRESS1 Great Ocean Road

GREY RIVER, VIC, 3234

Page No: A1. 6

1:200Scale:

Drawn By:NMDate Created: 27/04/20

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS.

COPYRIGHT ©

THIS IS THE SOLE PROPERTY OF P.J.SCOTT HOMES AND

MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

Geoff & Linda Andrew

CLIENTS

Date Modified: 22/09/21Date Issued: 22/09/21

SHADOWS

V1:Version Changes

SHADOWS 9.00am SEPTEMBER 22nd SHADOWS 12.00pm SEPTEMBER 22nd

SHADOWS 3:00pm SEPTEMBER 22nd

N

VACANT LAND(rcz)

VACANT LAND(rcz)

VACANT LAND(rcz)

Page 8: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. SITE SETOUT

CLIENTS:

JOB ADDRESS:

Custom Geoff & Linda Andrew1 Great Ocean Road

GREY RIVER, VIC, 3234Page No: A1. 7 Scale:

Drawn By:NMDate Created: 27/04/20Date Modified: 22/09/21Date Issued: 22/09/21

V1:Version Changes

2500

2500

13520

19785

45.95m

300°51'

47.82m

127°36'

16.0

9m

195°

20'

21.9

3m15

°20'

N

GRE

AT O

CEAN

RO

AD

7220

6350

1:200

*Setout from Boundary*

Boundary

27000

VACANT LAND(Rural Conservation Zone)

EXISTING SINGLE STOREY

DWELLING

1600

2000

CFA ACCESS POINTPIPED FROM UNDER HOUSE WATER TANKS

PROPOSED LOCATION OF CFA WATER TANKAND DRINKING WATER. UNDER HOUSE,PIPED TO FRONT OF PROPERTY FOR CFA ACCESS10,000 LITRES

Page 9: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. SITE CUT PLAN

CLIENTS:

JOB ADDRESS:

Custom Geoff & Linda Andrew1 Great Ocean Road

GREY RIVER, VIC, 3234Page No: A1. 8 Scale:

Drawn By:NMDate Created: 27/04/20Date Modified: 22/09/21Date Issued: 22/09/21

V1:Version Changes

RL 18.06

N/A

RL 17.91

SITE FILL

SITE CUT

APPROX. 600mm HIGH CONCRETE RETAINING WALLAPPROX. 3M LONG

Page 10: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. GROUND FLOOR PLAN

CLIENT:

JOB ADDRESS:

Custom Geoff & Linda Andrew

1 Great Ocean RoadGREY RIVER, VIC, 3234

Page No: A2. Scale:Drawn By:NM

Date Created: Date Modified: August 26, 2021Date Issued: September 20, 2021

V1:Version Changes

3/7/2020

7170

90 900 90 900 90 5010 90

8450

9046

8090

3500

90

9024

0090

2190

9035

0090

OVERALL

OVER

ALL

GARAGE

RUMPUS

PWD

N

W1 W2

W3

D1

D2

W4W5

Area SummaryGround FloorGarage

34.84m²

Total Area 61.11m² 6.57 sq's

26.27m²

1:100

RL 18.31

RL 18.46

1234567

8910111213

UP

Water Tanks(Located Under House)

150mm STEP

10,000 LITRE WATER TANKFOR DRINKING

10,000 LITRE CFA WATER TANK, WITH HOSERUNNING TO FRONT OF PROPERTY FORCFA ACCESS

Page 11: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. FIRST FLOOR PLAN

CLIENT:

JOB ADDRESS:

Custom Geoff & Linda Andrew

1 Great Ocean RoadGREY RIVER, VIC, 3234

Page No: A2. Scale:Drawn By:NM

Date Created: Date Modified: August 26, 2021Date Issued: September 20, 2021

V1:Version Changes

3/7/2020

19020

14020 30002000

90 3150 9051090 2900 90 90 1800 90 3120 90900 90 900

8450

3470

1200

3780

9032

9090

1200

9036

0090

9016

0090

1600

9012

0090

9017

1018

00

OVERALL

14020

90 3500 90 1450 90 900 90610 7110

90

90 3500 90 2440 90 7720 90

9024

1090

1200

790

9090

3600

90

9032

9090

4890

90

8450

OVER

ALL

BED 1

WIR

ENS

BED 2 BED 3

KITCHEN

LIVING

DINING

LDRYBATH

WC

W6 W7 W8

W9

D3

W10W11W12W13

W14

D4

W15

Area SummaryFirst FloorDeck

122.67m²

Total Area 160.47m² 17.27 sq's

37.80m²

N

1:100

RL 21.30

11234567

8910111213

DN

2000

3800

1200

5450

SD

Page 12: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. ELEVATIONS

CLIENT:

JOB ADDRESS:

Custom Geoff & Linda Andrew

1 Great Ocean RoadGREY RIVER, VIC, 3234

Page No: A2. Scale:Drawn By:NM

Date Created: Date Modified: August 26, 2021Date Issued: September 20, 2021

V1:Version Changes

3/7/2020

7.5M AboveNatural Ground Line

Colorbond Roof at 10° PitchColour: Woodland Grey

Colorbond CorrugatedColour: Wallaby

Timber Post

Garage Floor RL: 18.31

First Floor RL: 21.30

Garage Floor RL: 18.31

First Floor RL: 21.30

Ground Floor RL: 18.46

7.5M AboveNatural Ground Line

Colorbond Roof at 15° PitchColour: Woodland Grey

Colorbond CorrugatedColour: Wallaby

Timber Post

WEST ELEVATION

SOUTH ELEVATION

Natural Ground Line

Natural Ground Line

7100

(O

VER

ALL

)71

00 (

OVER

ALL

)

W3D1D2

W9D3

W4W5

W11W12W13W14

James Hardie Linea BoardColour: Haymes "Wilderness"

1100

Colourbond Woodland Grey

Colourbond Woodland Grey

1000

James Hardie Linea BoardColour: Haymes "Wilderness"

CONCRETE RETAINING WALL

1:100

Page 13: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. ELEVATIONS

CLIENT:

JOB ADDRESS:

Custom Geoff & Linda Andrew

1 Great Ocean RoadGREY RIVER, VIC, 3234

Page No: A2. Scale:Drawn By:NM

Date Created: Date Modified: August 26, 2021Date Issued: September 20, 2021

V1:Version Changes

3/7/2020

EAST ELEVATION

NORTH ELEVATION

First Floor RL: 21.30

First Floor RL: 21.30

Ground Floor RL: 18.46

7.5M AboveNatural Ground Line

Colorbond Roof at 15° PitchColour: Woodland Grey

Colorbond CorrugatedColour: Wallaby

Timber Post

Natural Ground Line

7.5M AboveNatural Ground Line

Colorbond Roof at 15° PitchColour: Woodland Grey

Colorbond CorrugatedColour: Wallaby

Natural Ground Line

W1

W2W2

W8 W7 W6

W14W15

1:100

James Hardie Linea BoardColour: Haymes "Wilderness"

James Hardie Linea BoardColour: Haymes "Wilderness"

1000

1000

Colorbond Roof at 10° PitchColour: Woodland Grey

Approx location of Solar Panels

Page 14: GREY RIVER, VIC, 3234

P J Scott Homes 1D Baines Cres.,

TORQUAYPH: (03) 5261 4924

COPYRIGHT © THIS IS THE SOLE PROPERTY

OF P.J.SCOTT HOMES AND MAY NOT BE USED IN WHOLE OR PART WITHOUT EXPRESS

WRITTEN PERMISSION

CONTRACTORS MUST VERIFYALL DIMENSIONS AND LEVELS

ON SITE PRIOR TO COMMENCING

ANY WORK OR MAKING ANY SHOP DRAWINGS.

DO NOT SCALE DRAWINGS ALWAYS USE WRITTEN

DIMENSIONS. ROOF

CLIENT:

JOB ADDRESS:

Custom Geoff & Linda Andrew

1 Great Ocean RoadGREY RIVER, VIC, 3234

Page No: A2. 1 Scale:Drawn By:NM

Date Created: Date Modified: August 26, 2021Date Issued: September 20, 2021

V1:Version Changes

3/7/2020

Colourbond Corrugated Iron Roof Monument @ 10 Deg on Metal Battens @ 900C/C with Safety batten between on Trusses to Manufactures Specs @ 900 C/C with Metal Ceiling Battens @450 C/C and 10mm Plaster Ceiling

10 Deg

15 Deg

1:100

DP DP

DP DP

Colourbond Corrugated Iron Roof Monument @ 15 Deg on Metal Battens @ 900C/C with Safety batten between on Trusses to Manufactures Specs @ 900 C/C with Metal Ceiling Battens @450 C/C and 10mm Plaster Ceiling

Down Pipes, Fascia and Gutter to be Colorbond 'Monument'

Approximate location of Solar Panels