GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to...

5
GREN Analysis Notes Jessica Leonard 7 Feb. 2008

Transcript of GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to...

Page 1: GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to most of data not in correct time sample (“sample of interest”)

GREN Analysis Notes

Jessica Leonard7 Feb. 2008

Page 2: GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to most of data not in correct time sample (“sample of interest”)

Issue: HCAL Timing

● Depending on run, half to most of data not in correct time sample (“sample of interest”)

● Solution: hack RCT code to loop over all samples in each digi, take the one with highest energy

Page 3: GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to most of data not in correct time sample (“sample of interest”)

Issue: RCT isolation

● All data candidates are non-isolated, all emulator candidates were isolated:

● Reason: EISO ASIC treats threshold of 0 differently from other values

● Emulator file updated

Entry: 0 (event:67 | run:30205)

sys:RCT (2), type:RCT em ... number of candidates: 2 un-matched (2) data: 0x0045, rank=0x05, region=1, card=0, crate=13, iso=0, index=2, bx=0 emul: 0x0045, rank=0x05, region=1, card=0, crate=13, iso=1, index=2, bx=0

data: 0x00d7, rank=0x17, region=1, card=1, crate=17, iso=0, index=3, bx=0 emul: 0x00d7, rank=0x17, region=1, card=1, crate=17, iso=1, index=3, bx=0

Page 4: GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to most of data not in correct time sample (“sample of interest”)

Issue: Energy differences

● Occasionally see data < emul by 4:

● Only happens in Crate 3 – hardware?● To be checked out when we have some rack time● May be causing some candidates to show up in

emulator only● Rare differences in other crates: may be due to

looking for what we think is correct data?

data: 0x0181, rank=0x01, region=0, card=3, crate= 3, iso=0, index=1, bx=0 emul: 0x0185, rank=0x05, region=0, card=3, crate= 3, iso=1, index=1, bx=0

Page 5: GREN Analysis Notes Jessica Leonard 7 Feb. 2008. Issue: HCAL Timing ● Depending on run, half to most of data not in correct time sample (“sample of interest”)

Comparator Summary (30185)