Gozzer Ranch
Water and Wastewater System
Overview
Dan Messier
North Kootenai Water and Sewer District
Coeur d’Alene, Idaho
North Kootenai Water and Sewer
District
• Serve 15 small communities with potable water
• 2 Surface water treatment plants
• 1 Water Reclamation Plant
• Over 4000 customers
• 5 member board of directors
Operations Staff
• 5 construction &
maintenance specialists
• 1 Field Supervisor
• 1 Wastewater Manager
• 1 part time electrician
• 3 office staff
• 1 District Manager
Gozzer Ranch Golf and Lake Club
• 600 acre site
• 120 acres of golf
course
• Golf course designed
by Tom Fazio
• Water Taxi service
from Coeur d’Alene to
site
Gozzer Ranch Golf and Lake Club
• Built on solid basalt
mountain - all water
and sewer lines had
to be blasted in.
• Encompasses Arrow
Point community
• Marina
• Eddie’s Restaurant
Surface Water Treatment Plant
• 4 submersible lake intake pumps mounted on sled in Coeur d’Alene Lake
• System limited to 2 cfs or roughly 900 gallons a minute
• Pumps provide water for drinking water as well as irrigation usage
Surface Water Treatment Plant
• 4 slow sand filtration
beds
• 900 gpm capacity
• 150,000 gallon
standpipe reservoir
• SCADA controlled
Surface Water Treatment Plant
Water Reclamation Plant
• Serves all of Gozzer Ranch and Arrow point Community Sewer Systems-583 ER’s
• Class A recycled water
• U.S. Filter Memjet Membrane filtration System
Water Reclamation Plant
• 130,000 gpd Membrane Bio Reactor
• 1 MG Bypass/ Storage Pond
• 7 MG Golf Lake
• Activated Carbon Air Scrubber
• SCADA System
• UV Disinfection System
• Methanol Injection
Water Reclamation Plant
• Prescreening
• Anoxic Zone
• Aeration chamber
• Membrane tank-2 modules
• 2 Membrane racks per module
• 32 membranes per Rack
• Ultraviolet disinfection
Water Reclamation Plant
Plant Effluent limits
• 2.2 Total Coliform 7 day mean average
• 30 mg/l Total Nitrogen
• 10 mg/l BOD
• 0.2 NTU Mean Turbidity – 0.5 NTU Max
• Class III Operator
• No restriction on application
• No land Application Permit required
Golf course pond
Golf course pond