INTERSTATE COUNCIL FOR STANDARTIZATION, METROLOGY AND CERTIFICATION (ISC) I N T E R S T A T E S T A N D A R D GOST 9544 – 2005 On-Off pipeline Valves CLASSES AND RATES OF TRIM LEAKAGE Official edition This copy is an official document of ANO “Novgorodskiy CSM” Velikiy Novgorod Moscow Standartinform 2008 BZ 5- 2000/107

description

GOST 9544- 2005_English

Transcript of GOST_9544-2005_eng_00.pdf

Page 1: GOST_9544-2005_eng_00.pdf

INTERSTATE COUNCIL FOR STANDARTIZATION, METROLOGY AND CERTIFICATION

(ISC)

I N T E R S T A T E

S T A N D A R D GOST9544 –

2005

On-Off pipeline Valves

CLASSES AND RATES OF TRIM LEAKAGE

Official edition

This copy is an official document of

ANO “Novgorodskiy CSM” Velikiy Novgorod

Moscow Standartinform

2008

BZ

5- 2

000/

107

Page 2: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005

Foreword

The objectives, underlying principles and basic procedure of carrying out the interstate standardization are determined by GOST 1.0 – 92 “Interstate standardization system. Basic regulations” and GOST 1.2 – 97 “Interstate standardization system. Interstate standards, rules and recommendations for interstate standardization. The procedure of development, passing, application, updating and repeal” The standard data 1 DEVELOPED by Technical committee for standardization TK 259 “Pipeline valves and bellows” 2 INTRODUCED by the Russian Federation Federal agency for technical regulation and metrology 3 PASSED by Interstate council for standardization, metrology and certification by correspondence (protocol No 22 dated November 4, 2005.) The passing is voted for by:

The short name of the country by QM (ISO 3166) 004 - 97

The country code by QM (ISO 3166) 004 - 97

The short name of the national standardization body

Azerbaijan Armenia Kazakhstan Kyrgyzstan Moldova The Russian Federation Tajikistan Turkmenistan Uzbekistan Ukraine

AZ AM KZ KG MD RU

TJ

TM UZ UA

Azstandart Mintorgeconomrazvitiya Republic Kazakhstan Gosstandart Kyrgyzstandart Moldova – Standart Federal agency for technical regulation and metrology Tajikstandart Glavgossluzhba “Turkmenstandartlary” Uzstandart Gospotrebstandart of Ukraine

4 This standard conforms to international standard ISO 5208 – 82 “Industrial valves. Valves pressure test” in the part concerning gates sealibility tests 5 The interstate standard GOST 9544 – 2005 has been commissioned as a national standard in the Russian Federation since April 1, 2008 under the order No 23-st dated February 29, 2008 issued by Federal agency for technical regulation and metrology. 6 INSTEAD OF GOST 9544 – 93 Information concerning the commissioning and determination of this standard is published in the directory “National standards”. Information concerning the amendments to this standard is published in the directory (the catalogue) “National standards”, the amendments text is published in the informational directories “National standards”. In case of a revision or the reversal of this standard is made the corresponding information will be published in the informational directory “National standards”

© Standartinform, 2008

Any reproduction of this standard, either complete or partial, or replication, or distribution as an official edition on the territory of the Russian Federation without Federal agency for technical regulation and metrology permission is prohibited.

Page 3: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005

Table of contents

1 Scope of application……………………………………………………………………………………1 2 Standard reference……………………………………………………………………………………1 3 Terms and definitions…………………………………………………………………………………..1 4 Requirements…………………………………………………………………………………………...2 Bibliography…………………………………………………………………………………………….11

Page 4: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005

I N T E R S T A T E S T A N D A R D

On-off pipeline valves

CLASSES AND RATES OF TRIM LEAKAGE

Introduction date – 2008 – 04 – 01

1 Scope of application This standard applies to all the types of on-off pipeline valves with nominal pressure PN from 0,1

MPa and sets standards for rates of trim leakage and classes of trim leakage as well as determines corresponding allowable leakages of test media and requirements for trim leakage tests within commissioning tests and other kinds of pipeline tests.

This standard does not apply to the valves designed and manufactured subject to a customer’s specific requirements with reference to particular service conditions.

This standard is allowed to be applied to other types of pipeline valves. This standard is suitable for the purposes of certification.

2 Standard references This standard uses a reference to the following standard: GOST 17433 – 80 Industrial purity. Compressed air. Pollution classes

N o t i c e – When applying this standard it is recommended to verify the validity of the standard references with help of the directory “National standards”, compiled as of January, 1 of the current year, and using corresponding informational directories, published during the current year. If a standard reference has been substituted (altered), one is to be guided by the substituting (altered) standard when applying this standard. If a reference standard has been repealed without a substitute, the provision containing a reference to it is to be applied to the extent of not containing this reference.

3 Terms and definitions The following terms with corresponding definitions are used in this standard: 3.1 on-off valves: Industrial pipeline valves meant for the shutoff of working media stream. 3.2 test media: Media leaking through a closed trim or valve joints and detected during control of trim leakage and tightness. 3.3 nominal pressure: maximum working overpressure at the working media temperature 20°C providing a specified service life of a valve with dimensions founded by strength analysis for chosen materials and their strength characteristics at the temperature of 20°C. 3.4 nominal diameter: A characteristic of joining parts, e.g. the joints of pipelines, fittings and valves. The nominal diameter does not have a unit measurement and it is approximately equivalent to the inner diameter (mm) of a joining pipeline. A nominal bore (a nominal diameter) is to be indicated as DN together with a numeric value, chosen from a row. 3.5 manufacturer: a company manufacturing valves and (or) carrying out tests. 3.6 trim: The system of a moving (a spindle, a disk etc) and a static (a seat) part of a valve blocking element, forming (an opened trim) an orifice or (a closed trim) a tight joint. _____________________________________________________________________________________ Official edition

1

Page 5: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005

3.7 trim tightness: A trim ability to prevent either a gas or a liquid exchange between the media separated by the trim. 3.8 trim leakage class: A trim characteristic estimating maximum allowable leakage of the test media through the trim. 3.9 leakage: An escape of the media from a leak-tight product through the leaks under the influence of total or partial pressure differential. 3.10 trim leakage test: A test estimating the trim tightness after its being effected by test media under pressure stated in standards, technical conditions (TC), design documentation (DD) for the valves. 3.11 trim leakage control: Technical control of test media trim leakage value conformance to a certain leakage class.

4 Requirements This standard determines: 4.1 Valve nominal pressures range from PN 1 up to PN 420. Nominal pressures are measured in kgf/cm². 4.2 Valve nominal diameters range in mm – from DN 3 up to DN 2000. 4.3 The following trim leakage classes are standard: A, B, C, D, B1, C1 and D1. 4.3.1 The developer is to indicate both the trim leakage class (see 3.7) and the test media (see 3.2) in standards, TC, DD for the valves. A n e x a m p l e of documental recording for trim leakage class C, the test media “air”: “The trim leakage class – C by GOST 9544 – 2005. The test media – “air” 4.3.2 For valves trims class A with nominal diameters from DN 3 up to DN 200 at nominal pressure from PN 1 up to PN 420 and with nominal diameters from DN 250 up to DN 2000 at nominal pressure from PN 1 up to PN 200 the following qualitative criterion of tightness is standard – the absence of visible leakage during retention interval. The test is performed either by air at pressure 6 kgf/cm² or by water at nominal pressure multiplied by 1,1. It is allowed to test valve trims with nominal diameters from DN 3 up to DN 200 by air at nominal pressure. The following does not represent rejection criteria of valve trims: - during a hydraulic test – dew gathering on a sealing surface profile which does not turn into flowing drips; - during a pneumatic test – generation of breaking loose bubbles. 4.4 The retention interval when controlling valve trim leakages for all leakage classes is to conform to the one shown in table 1. T a b l e 1

Retention interval, seconds, no less than Nominal diameter (nominal bore) DN, mm water air

Up to DN 50 inclusive Over DN 50

120 180

60 120

4.5 Allowable leakages for all types of on-off valves trims are shown: - test media “air”: for class B – in table 2, for class B1 – in table 3, for class C – in table 5, for class C1 – in table 6, for class D – in table 8, for class D1 – in tables 9; - test media “water”: for classes B, C, D and D1 – in table 11. 4.5.1 Allowable leakages shown in table 11 for classes B, C and D apply to valve trims with nominal diameters from DN 3 up to DN 200 at nominal pressures from PN 1 up to PN 420; and with nominal diameters from DN 250 up to DN 2000 at nominal pressures from PN 1 up to PN 200; for class D – with nominal diameters from DN 1 up to DN 2000 at nominal pressures from PN 1 up to PN 200. N o t i c e – Classes A, B, C and D – in [1]. 2

Page 6: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005

4.6 Allowable leakages for trims shown in tables 4, 7 and 10 apply to on-off and gate valves pneumatic test at pressure 6 kgf/cm². 4.7 Allowable leakages shown in tables 4, 7 and 10, apply to a trim closing force produced by a torque value Mkr which is calculated so that it provides unit pressure equal to one obtained during a test at nominal pressure on the sealing surfaces. Torque value Mkr is stated in DD and (or) in TC. 4.8 Test media pressure 4.8.1 Air pressure – by tables 2 – 10. A n e x a m p l e of documental recording for test media “air” at pressure 6 kgf/cm² (or at a nominal one): “Trim leakage class – C1, test media – “air” at pressure 6 kgf/cm² (or at a nominal one)” 4.8.2 Water pressure, kgf/cm², must correspond to a numeric value of a valve nominal pressure multiplied by 1,1. E.g. for a valve PN 100 the water pressure is to be 110 kgf/cm². 4.8.3 Pressure metering error - ±2%. 4.9 Test media 4.9.1 This standard regulates allowable leakages with the use of the following test media: air by GOST 17433, water by [2]. 4.9.2 At a manufacturer’s discretion it is allowed to use water and air by other norms or test media-substitutes, e.g. gas-nitrogen, providing that neither physical nor chemical properties of test media are deteriorated. In these cases the manufacturer guarantees the conformance of valve trims to leakage classes, stated in this standard. 4.9.3 It is allowed to use natural gas as test media during the test. During the test with the use of natural gas allowable leakages are to be equal to allowable leakages for air (tables 2 – 10) multiplied by 1,75. 4.9.4 The test media temperature during the test is to be 5°C - 40°C. 4.10 Trim leakage test is performed after closing of the valve blocking element as it is stipulated in TC for valves of a certain type. 4.11 Allowable leakages are stated in this standard for the conditions of fugitive emissions of the test media. Leakage metering error is to be no more than: ±0,01cm³/min – for leakages no more than 0,1cm³/min; ± 5% - for leakages over 0,1cm³/min. T a b l e 2 – Allowable trim leakages for test media “air”. Class B

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN 6,3

PN 10

PN 16

PN 20

PN 25

PN 40

PN 50

PN 63

PN 80

PN 100

PN 125

PN 160

PN 200

PN 250

PN 320

DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200

0,054 0,108 0,180 0,270 0,360 0,450 0,576 0,720 0,900 1,170 1,440 1,700 2,250 2,700 3,600

0,054 0,108 0,180 0,270 0,360 0,450 0,576 0,720 0,900 1,170 1,440

- - - -

Page 7: GOST_9544-2005_eng_00.pdf

3 GOST 9544 – 2005 T a b l e 3 – Allowable trim leakages for test media “air”. Class B1

Allowable leakages, cm³/min, pneumatic test at nominal pressure kgf/cm² Nominal pressure

DN

PN 1 PN 1,6 PN 2,5 PN 4 PN 6,3 PN 10 PN 16 PN 25 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400

0,01 0,01 0,06 0,10 0,20 0,30 0,40 0,60 0,70 1,20 1,50 2,50 3,00 4,00 6,00 9,00 12,00 15,00 18,00

0,01 0,02 0,08 0,13 0,25 0,35 0,50 0,75 0,95 1,35 1,75 2,75 3,50 5,00 7,50 11,00 15,00 17,50 21,50

0,01 0,03 0,10 0,15 0,30 0,40 0,60 0,90 1,20 1,50 2,00 3,00 4,00 6,00 9,00 13,00 18,00 20,00 25,00

0,02 0,06 0,15 0,20 0,40 0,60 0,80 1,20 1,50 2,00 3,00 4,00 6,00 9,00 12,00 18,00 25,00 30,00 35,00

0,03 0,10 0,20 0,30 0,60 0,80 1,20 1,60 2,10 3,00 4,00 6,00 9,00

12,00 17,00 26,00 32,00 40,00 50,00

0,06 0,15 0,30 0,40 0,70 1,00 1,50 2,00 3,00 4,00 6,00 9,00

12,00 16,00 25,00 35,00 45,00 60,00 65,00

0,10 0,20 0,40 0,70 1,00 1,50 2,00 3,00 4,00 7,00 8,00

13,00 18,00 25,00 35,00 50,00 70,00 90,00 100,00

0,15 0,30 0,60 1,00 1,50 2,00 3,50 4,00 7,00

10,00 13,00 18,00 25,00 35,00 50,00 70,00 100,00 120,00 150,00

The end of table 3

Allowable leakages, cm³/min, pneumatic test at nominal pressure kgf/cm² Nominal pressure

DN

PN40 PN63 PN80 PN100 PN125 PN160 PN200 PN250 PN320 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400

0,20 0,40 1,00 2,00 2,50 3,00 6,00 7,00 10,00 15,00 20,00 30,00 35,00 50,00 80,00 120,00 150,00 200,00 250,00

0,25 0,80 1,50 3,00 4,00 6,00 8,00 12,00 17,00 25,00 35,00 45,00 65,00 90,00

130,00 200,00 250,00 300,00 400,00

0,30 0,90 2,00 3,50 5,50 8,00

10,00 15,50 21,50 32,50 42,50 57,50 82,50 120,00 165,00 250,00 325,00 425,00 500,00

0,40 1,00 2,50 4,00 7,00 10,00 12,00 18,00 26,00 40,00 50,00 70,00

100,00 150,00 200,00 300,00 400,00 500,00 600,00

0,50 1,20 3,00 5,20 8,50 12,50 15,00 22,00 28,00 47,50 60,00 95,00

135,00 175,00 260,00 375,00 500,00 625,00 750,00

0,60 1,50 3,50 7,00 10,00 15,00 18,00 26,00 30,00 55,00 70,00

120,00 170,00 200,00 320,00 450,00 600,00 750,00 900,00

0,80 2,00 4,50 9,00 12,00 20,00 30,00 35,00 55,00 70,00

100,00 150,00 220,00 300,00 450,00 600,00 750,00

1000,00 1200,00

0,60 1,50 2,50 6,00 9,00 15,00 20,00 30,00 35,00 55,00 70,00

100,00 150,00 220,00 315,00

- - - -

0,30 0,40 0,60 1,00 1,50 1,90 3,00 4,00 5,50 7,00 10,00 15,00 22,00 30,00 45,00

- - - -

Page 8: GOST_9544-2005_eng_00.pdf

4 GOST 9544 – 2005

T a b l e 4 – Allowable trim leakages for test media “air”. Class B1

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN6,3

PN10

PN16

PN20,

PN25

PN40

PN63

PN80

PN100

PN125

PN160

PN200

PN250

PN320

DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400

0,030 0,100 0,200 0,300 0,500 0,800 1,200 1,500 2,000 3,000 4,000 6,000 8,000 12,000 16,000 25,000 30,000 40,000 45,000

0,020 0,060 0,120 0,160 0,270 0,400 0,600 0,760 1,270 1,600 2,560 3,690 4,800 6,400 10,180 14,400 18,000 24,000 26,000

0,020 0,030 0,070 0,120 0,170 0,250 0,340 0,510 0,680 1,190 1,360 2,210 3,060 4,250 5,950 8,500 11,900 15,300 17,000

0,010 0,020 0,040 0,070 0,110 0,140 0,250 0,270 0,500 0,710 0,910 1,280 1,770 2,480 3,550 4,970 7,100 8,520 10,650

0,006 0,012 0,029 0,058 0,073 0,087 0,174 0,203 0,290 0,435 0,580 0,870 1,015 1,450 2,320 3,480 4,350 5,800 7,250

0,003 0,009 0,016 0,033 0,044 0,066 0,088 0,143 0,187 0,275 0,385 0,495 0,715 0,990 1,430 2,200 2,750 3,850 4,400

0,002 0,006 0,014 0,024 0,039 0,056 0,070 0,109 0,150 0,230 0,298 0,402 0,578 0,840 1,155 1,750 2,280 2,980 3,500

0,002 0,005 0,012 0,020 0,035 0,050 0,060 0,090 0,130 0,200 0,250 0,350 0,500 0,750 1,000 1,500 2,000 2,500 3,000

0,001 0,004 0,009 0,016 0,026 0,038 0,045 0,066 0,084 0,143 0,180 0,285 0,405 0,525 0,780 1,125 1,410 1,875 2,250

0,001 0,003 0,007 0,014 0,020 0,030 0,036 0,052 0,060 0,110 0,140 0,240 0,340 0,400 0,640 0,900 1,200 1,500 1,800

0,001 0,002 0,005 0,009 0,012 0,020 0,030 0,035 0,055 0,070 0,100 0,150 0,220 0,300 0,450 0,600 0,750 1,000 1,200

0,001 0,001 0,002 0,006 0,009 0,010 0,020 0,030 0,035 0,055 0,070 0,100 0,150 0,220 0,315

- - - -

0,001 0,001 0,001 0,001 0,001 0,002 0,003 0,004 0,005 0,007 0,010 0,015 0,022 0,030 0,045

- - - -

T a b l e 5 – Allowable trim leakages for test media “air”. Class C

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN 6,3

PN 10

PN 16

PN 20

PN 25

PN 40

PN 50

PN 63

PN 80

PN 100

PN 125

PN 160

PN 200

PN 250

PN 320

DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200

0,54 1,08 1,80 2,70 3,60 4,50 5,76 7,20 9,00 11,70 14,40 17,00 22,50 27,00 36,00

0,54 1,08 1,80 2,70 3,60 4,50 5,76 7,20 9,00 11,70 14,40

- - - -

Page 9: GOST_9544-2005_eng_00.pdf

5 GOST 9544 – 2005 T a b l e 6 – Allowable trim leakages for test media “air”. Class С1

Allowable leakages, cm³/min, pneumatic test at nominal pressure kgf/cm² Nominal pressure

DN

PN 1 PN 1,6 PN 2,5 PN 4 PN 6,3 PN 10 PN 16 PN20, PN 25 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,01 0,06 0,15 0,25 0,60 0,90 1,30 1,80 2,50 3,50 4,50 7,00 9,00 13,00 18,00 25,00 35,00 45,00 50,00 85,00

110,00 160,00 240,00 300,00 400,00 550,00 650,00

0,02 0,08 0,20 0,33 0,75 1,10 1,50 2,15 3,00 4,25 5,70 8,50 11,00 15,00 21,50 32,50 42,50 52,50 62,50

102,50 145,00 205,00 295,00 375,00 475,00 675,00 825,00

0,03 0,09 0,25 0,40 0,90 1,30 1,80 2,50 3,50 5,00 7,00 10,00 13,00 18,00 25,00 40,00 50,00 60,00 75,00

120,00 160,00 250,00 350,00 450,00 550,00 700,00 1000,00

0,06 0,15 0,30 0,60 1,30 1,80 2,50 3,50 4,50 7,00 9,00 13,00 18,00 25,00 35,00 50,00 75,00 90,00

100,00 160,00 220,00 340,00 350,00 600,00 750,00 900,00 1300,00

0,10 0,25 0,50 0,90 1,80 2,50 3,50 4,50 6,00 9,00

12,00 18,00 25,00 35,00 45,00 75,00 100,00 120,00 130,00 220,00 280,00 450,00 600,00 850,00

1000,00 1200,00 1800,00

0,20 0,40 0,90 1,30 2,50 3,50 5,00 6,00 9,00

13,00 18,00 25,00 35,00 45,00 75,00 100,00 150,00 180,00 200,00 320,00 440,00 650,00 900,00

1200,00 1500,00 1800,00 2600,00

0,30 0,60 1,20 2,00 3,00 4,50 7,00 9,00

13,00 20,00 25,00 40,00 50,00 80,00 100,00 160,00 200,00 250,00 300,00 500,00 650,00

1000,00 1500,00 1800,00 2400,00 2700,00 4000,00

0,40 0,90 1,50 3,50 5,00 7,00 10,00 13,00 20,00 30,00 40,00 50,00 80,00

100,00 160,00 200,00 300,00 400,00 450,00 700,00 1000,00 1500,00 2000,00 2600,00 3200,00 4100,00 6000,00

The end of table 6

Allowable leakages, cm³/min, pneumatic test at nominal pressure kgf/cm² Nominal pressure

DN

PN 40 PN 63 PN 80 PN 100 PN 125 PN 160 PN200 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,50 1,20 2,50 5,00 9,00 10,00 18,00 25,00 30,00 45,00 60,00 90,00

120,00 150,00 250,00 350,00 450,00 600,00 800,00 1100,00 1500,00 2300,00 3200,00 4500,00 5400,00 6500,00 9500,00

0,80 2,00 4,00 8,50 13,00 18,00 25,00 35,00 50,00 80,00

100,00 130,00 200,00 250,00 400,00 600,00 750,00 950,00 1200,00 1800,00 2400,00 3600,00 5000,00 6500,00 8200,00

10000,00 15000,00

1,00 2,70 5,50 10,50 15,50 21,50 32,50 42,50 65,00

100,00 125,00 175,00 250,00 350,00 500,00 750,00 975,00 1250,00 1500,00 2350,00 3200,00 4300,00 6500,00 8750,00

10600,00 13000,00 19500,00

1,20 3,50 7,00 12,00 18,00 25,00 40,00 50,00 80,00

120,00 150,00 220,00 300,00 450,00 600,00 900,00 1200,00 1500,00 1800,00 2900,00 4000,00 6000,00 8000,00

11000,00 13000,00 16000,00 24000,00

1,50 4,20 8,50 16,00 24,00 35,00 50,00 65,00

100,00 150,00 200,00 290,00 375,00 525,00 750,00 1050,00 1600,00 1750,00 2150,00 3700,00 5000,00 7500,00

10000,00 13500,00 17000,00 21000,00 31000,00

1,80 5,00 10,00 20,00 30,00 45,00 60,00 80,00

120,00 180,00 250,00 360,00 450,00 600,00 900,00 1200,00 2000,00 2300,00 2500,00 4500,00 6000,00 9000,00

12000,00 16000,00 21000,00 26000,00 38000,00

2,00 6,00 13,00 25,00 40,00 60,00 90,00

100,00 160,00 220,00 300,00 450,00 600,00 900,00 1300,00 1800,00 2500,00 3000,00 4000,00 6000,00 8000,00

12000,00 17000,00 22000,00 28000,00 35000,00 48000,00

Page 10: GOST_9544-2005_eng_00.pdf

6 GOST 9544 – 2005

T a b l e 7 – Allowable trim leakages for test media “air”. Class С1

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN 6,3 PN 10 PN 16 PN 20, PN 25 PN 40 PN63 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,100 0,200 0,500 0,900 1,800 2,500 3,500 4,500 6,000 9,000

12,000 18,000 25,000 35,000 45,000 75,000 100,000 120,000 130,000 220,000 280,000 450,000 600,000 850,000 1000,00 1200,00 1800,00

0,080 0,160 0,360 0,520 1,000 1,400 2,000 2,400 3,600 5,200 7,200

10,000 14,000 18,000 30,000 40,000 60,000 72,000 80,000 128,000 176,000 260,000 360,000 480,000 600,000 720,000

1040,000

0,040 0,100 0,190 0,340 0,510 0,760 1,190 1,530 2,210 3,400 4,250 6,800 8,500

13,600 17,000 27,200 34,000 42,500 51,000 65,000 110,000 170,000 255,000 306,000 408,000 459,000 680,000

0,030 0,070 0,110 0,250 0,350 0,500 0,700 0,900 1,400 2,100 2,800 3,500 5,700 7,100

11,400 14,200 21,300 28,400 32,000 49,700 71,000 106,000 142,000 185,000 227,000 291,000 426,000

0,010 0,030 0,070 0,140 0,260 0,290 0,520 0,730 0,870 1,300 1,740 2,610 3,480 4,350 7,250

10,150 13,050 17,400 23,200 32,000 43,000 67,000 93,000 130,000 157,000 188,000 275,000

0,010 0,020 0,040 0,100 0,120 0,130 0,270 0,380 0,550 0,880 1,100 1,430 2,200 2,750 4,400 6,600 8,250

11,000 13,200 19,800 26,400 39,600 55,000 71,500 90,200 110,000 165,000

The end of table 7

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN 80 PN 100 PN 125 PN 160 PN 200 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,007 0,019 0,038 0,073 0,108 0,150 0,227 0,297 0,455 0,700 0,875 1,225 1,750 2,450 3,500 5,250 6,825 8,750

10,500 16,450 22,400 30,100 45,500 61,250 74,200 91,000

136,500

0,006 0,017 0,035 0,060 0,090 0,125 0,200 0,250 0,400 0,600 0,750 1,100 1,500 2,250 3,000 4,500 6,100 7,500 9,000

14,500 20,000 30,000 40,000 55,000 65,000 80,000

120,000

0,004 0,013 0,025 0,048 0,072 0,105 0,150 0,195 0,300 0,450 0,600 0,870 1,125 1,575 2,250 3,150 4,800 5,250 6,450

11,100 15,000 22,500 30,000 40,500 51,000 63,000 93,000

0,004 0,010 0,020 0,040 0,060 0,090 0,120 0,160 0,240 0,360 0,500 0,720 0,900 1,200 1,800 2,400 4,000 4,000 5,000 9,000

12,000 18,000 24,000 32,000 42,000 52,000 76,000

0,002 0,006 0,013 0,025 0,040 0,060 0,090 0,100 0,160 0,220 0,300 0,450 0,600 0,900 1,300 1,800 2,500 3,000 4,000 6,000 8,000

12,000 17,000 22,000 28,000 35,000 48,000

Page 11: GOST_9544-2005_eng_00.pdf

7 GOST 9544 – 2005 T a b l e 8 – Allowable trim leakages for test media “air”. Class D

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN 6,3

PN 10

PN 16

PN 20

PN 25

PN 40

PN 50

PN 63

PN 80

PN 100

PN 125

PN 160

PN 200

PN 250

PN 320

DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200

5,4 10,8 18,0 27,0 36,0 45,0 57,6 72,0 90,0 117,0 144,0 170,0 225,0 270,0 360,0

5,4 10,8 18,0 27,0 36,0 45,0 57,6 72,0 90,0 117,0 144,0

- - - -

T a b l e 9 – Allowable trim leakages for test media “air”. Class D1

Allowable leakages, cm³/min, pneumatic test at nominal pressure kgf/cm² Nominal pressure

DN

PN 1 PN 1,6 PN 2,5 PN 4 PN 6,3 PN 10 PN 16 PN20, PN 25

DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,1 0,2 0,6 0,9 2,0 3,0 4,5 6,0 8,0

12,0 15,0 25,0 30,0 45,0 60,0 90,0 120,0 150,0 180,0 250,0 350,0 500,0 700,0

1000,0 1200,0 1600,0 2000,0

0,1 0,2 0,7 1,2 2,5 3,7 5,2 7,5

10,0 15,0 20,0 30,0 37,5 52,5 75,0 115,0 150,0 175,0 215,0 300,0 425,0 650,0 850,0

1200,0 1400,0 1800,0 2500,0

0,1 0,3 0,9 1,5 3,0 4,5 6,0 9,0

12,0 18,0 25,0 35,0 45,0 60,0 90,0 140,0 180,0 200,0 250,0 350,0 500,0 800,0

1000,0 1400,0 1600,0 2000,0 3000,0

0,2 0,6 1,2 2,0 4,5 6,0 8,0

12,0 15,0 25,0 30,0 45,0 60,0 90,0 120,0 180,0 250,0 300,0 350,0 500,0 650,0

1000,0 1400,0 1800,0 2200,0 2500,0 4000,0

0,3 0,9 1,8 3,0 6,0 8,0 12,0 15,0 20,0 30,0 40,0 60,0 80,0

120,0 150,0 250,0 350,0 400,0 450,0 650,0 800,0 1400,0 1800,0 2500,0 3000,0 3500,0 5500,0

0,6 1,5 3,0 4,5 8,0 12,0 16,0 20,0 30,0 45,0 60,0 90,0

120,0 150,0 250,0 350,0 500,0 600,0 800,0 1000,0 1300,0 2000,0 2700,0 3500,0 4500,0 5500,0 8000,0

1,0 2,0 4,5 8,0 10,0 15,0 25,0 30,0 45,0 70,0 90,0

140,0 180,0 250,0 350,0 550,0 800,0 900,0 1000,0 1500,0 2000,0 3000,0 4500,0 5500,0 7000,0 8000,0

12000,0

1,2 3,0 6,0

12,0 18,0 25,0 35,0 45,0 70,0 100,0 140,0 180,0 250,0 350,0 550,0 800,0

1000,0 1400,0 1500,0 2000,0 3000,0 4500,0 6000,0 8000,0 10000,0 12000,0 18000,0

Page 12: GOST_9544-2005_eng_00.pdf

8 GOST 9544 – 2005

The end of table 9 Allowable leakages, cm³/min, pneumatic test at nominal pressure kgf/cm²

Nominal pressure

DN

PN 40 PN 63 PN 80 PN 100 PN 125 PN 160 PN200 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

1,8 4,5 9,0

18,0 30,0 35,0 60,0 80,0 100,0 150,0 200,0 300,0 400,0 550,0 800,0

1200,0 1500,0 2000,0 2500,0 3500,0 4500,0 7000,0 10000,0 14000,0 16000,0 20000,0 30000,0

3,0 8,0

15,0 30,0 45,0 60,0 90,0 120,0 180,0 250,0 350,0 450,0 700,0 900,0

1400,0 2000,0 2500,0 3200,0 4000,0 5500,0 7000,0 10000,0 15000,0 20000,0 25000,0 30000,0 45000,0

3,7 10,0 19,5 35,0 52,5 75,0 115,0 150,0 215,0 325,0 425,0 625,0 850,0

1200,0 1700,0 2500,0 3250,0 4250,0 5000,0 7250,0 9500,0 14000,0 19500,0 25000,0 32500,0 40000,0 57500,0

4,5 12,0 24,0 40,0 60,0 90,0 140,0 180,0 250,0 400,0 500,0 800,0

1000,0 1500,0 2000,0 3000,0 4000,0 5000,0 6000,0 9000,0 12000,0 18000,0 24000,0 30000,0 40000,0 50000,0 70000,0

5,2 14,5 29,5 55,0 80,0 120,0 170,0 215,0 325,0 500,0 650,0

1000,0 1250,0 1750,0 2500,0 3750,0 5250,0 6500,0 7500,0 11500,0 15000,0 21500,0 29500,0 40000,0 50000,0 61500,0 85000,0

6,0 17,0 35,0 70,0 100,0 150,0 200,0 250,0 400,0 600,0 800,0

1200,0 1500,0 2000,0 3000,0 4500,0 6500,0 8000,0 9000,0 14000,0 18000,0 25000,0 35000,0 50000,0 60000,0 80000,0

100000,0

8,0 20,0 45,0 90,0 140,0 200,0 300,0 350,0 550,0 800,0

1000,0 1500,0 2000,0 3000,0 4500,0 6000,0 8000,0 10000,0 13000,0 18000,0 24000,0 35000,0 60000,0 65000,0 85000,0

100000,0 150000,0

T a b l e 10 – Allowable trim leakages for test media “air”. Class D1

Allowable leakages, cm³/min, pneumatic test at pressure 6 kgf/cm² Nominal pressure

DN

PN6,3

PN10

PN16

PN20,

PN25

PN40

PN63

PN80

PN100

PN125

PN160

PN200

DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,300 0,900 1,800 3,000 6,000 8,000 12,000 15,000 20,000 30,000 40,000 60,000 80,000

120,000 150,000 250,000 350,000 400,000 450,000 650,000 800,000 1400,000 1800,000 2500,000 3000,000 3500,000 5500,000

0,200 0,600 1,200 1,800 3,200 4,800 6,400 8,000

12,000 18,000 24,000 36,000 48,000 60,000 100,000 140,000 200,000 240,000 320,000 400,000 500,000 800,000

1080,000 1400,000 1800,000 2200,000 3200,000

0,170 0,340 0,760 1,360 1,700 2,550 4,250 5,100 7,650 11,900 15,300 23,800 30,600 42,500 59,500 93,500

136,000 153,000 170,000 255,000 340,000 510,000 765,000 935,000 1190,000 1360,000 2040,000

0,085 0,213 0,426 0,852 1,278 1,775 2,485 3,195 4,970 7,100 9,940

12,780 17,750 24,850 39,500 56,800 71,000 99,400 106,500 142,000 213,000 319,000 426,000 568,000 710,000 852,000

1278,000

0,052 0,131 0,261 0,522 0,870 1,015 1,740 2,320 2,900 4,350 5,800 8,700

11,600 15,950 23,200 34,800 43,500 58,000 72,500 101,500 130,500 203,000 290,000 406,000 464,000 580,000 870,000

0,033 0,088 0,165 0,330 0,495 0,660 0,990 1,320 1,980 2,750 3,850 4,950 7,700 9,900

15,400 22,000 27,500 35,200 44,000 60,500 77,000 110,000 165,000 220,000 275,000 330,000 495,000

0,026 0,070 0,137 0,245 0,368 0,525 0,805 1,050 1,505 2,275 2,975 4,375 5,950 8,400

11,900 17,500 22,750 29,750 35,000 50,750 66,500 98,000 136,500 175,000 227,500 280,000 402,500

0,023 0,060 0,120 0,200 0,300 0,450 0,700 0,900 1,250 2,000 2,500 4,000 5,000 7,500

10,000 15,000 20,000 25,000 30,000 45,000 60,000 90,000 120,000 150,000 200,000 250,000 350,000

0,016 0,044 0,089 0,165 0,240 0,360 0,510 0,645 0,975 1,500 1,950 3,000 3,750 5,250 7,500

11,250 15,750 19,500 22,500 34,500 45,000 64,500 88,500 120,000 150,000 184,500 255,000

0,012 0,034 0,070 0,140 0,200 0,300 0,400 0,500 0,800 1,200 1,600 2,400 3,000 4,000 6,000 9,000

13,000 16,000 18,000 28,000 36,000 50,000 70,000 100,000 120,000 190,000 200,000

0,008 0,020 0,045 0,090 0,140 0,200 0,300 0,350 0,550 0,800 1,000 1,500 2,000 3,000 4,500 6,000 8,000 10,000 13,000 18,000 24,000 35,000 60,000 65,000 85,000

100,000 150,000

Page 13: GOST_9544-2005_eng_00.pdf

9 GOST 9544 – 2005 T a b l e 11 – Allowable trim leakages for test media “water”

Allowable leakages, cm³/min, hydraulic test at nominal pressure multiplied by 1,1 kgf/cm² Leakage classes

DN

B C D D1 DN3 DN6 DN10 DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400 DN500 DN600 DN800 DN1000 DN1200 DN1400 DN1600 DN2000

0,002 0,004 0,006 0,009 0,012 0,015 0,018 0,024 0,030 0,040 0,048 0,060 0,075 0,090 0,120 0,150 0,180 0,210 0,240 0,300 0,360 0,480 0,600 0,720 0,840 0,960 1,200

0,004 0,011 0,018 0,027 0,036 0,045 0,058 0,072 0,090 0,117 0,144 0,180 0,225 0,270 0,360 0,450 0,570 0,630 0,720 0,900 1,080 1,440 1,800 2,160 2,520 2,880 3,600

0,018 0,036 0,060 0,090 0,120 0,150 0,192 0,240 0,300 0,390 0,480 0,600 0,750 0,900 1,200 1,500 1,800 2,100 2,400 3,000 3,600 4,800 6,000 7,200 8,400 9,600

12,000

0,010 0,020 0,050 0,100 0,150 0,200 0,300 0,400 0,600 0,900 1,100 1,600 2,200 3,000 4,500 6,500 8,000 11,000 13,000 17,000 24,000 35,000 50,000 65,000 80,000

100,000 140,000

10

Page 14: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005

Bibliography

[1] ISO 5208:1982* Industrial valves. Valves pressure test [2] GOST R 51232 – 98 Potable water. General requirements for establishment and procedures of quality control _________________ *Substituted for ISO 5208:1993

11

Page 15: GOST_9544-2005_eng_00.pdf

GOST 9544 – 2005 ________________________________________________________________________________________________ UDK 621.643.4:006.354 MKS 23.060 G18 OKP 37 0000 Key words: valves, leakage class, test media, leakage, trim ________________________________________________________________________________________________

Editor V.P. Kopysov Typographer N.S. Grishanova Proofreader M.V. Buchnaya

Computer makeup by A.N. Zolotareva

Passed for press 19.03.2008. Passed for printing 04.04.2008. Folio 60x84 1/8. Offset paper. Font Arial Offset lithography. Printing run 600 copies. Order 318.

_____________________________________________________________________________________________________________________ FSUE “STANDARTINFORM”, 123995, Moscow, Granatniy per., 4

www.gostinfo.ru [email protected] Composed in FSUE “STANDARTINFORM” on PC.

Printed in the subsidiary of FSUE “STANDARTINFORM” – Printery “Moskovskiy pechatnik”, 105062, Moscow, Lyalin per., 6.