GOLD Overview

24
www.swegon.com Energy-efficient, compact and flexible air handling units OVERVIEW GOLD TM & COMPACT TM

description

Swegon GOLD/COMPACT Air Handling Unit Overview Brochure

Transcript of GOLD Overview

Page 1: GOLD Overview

www.swegon.com

Energy-effi cient, compact and fl exible air handling units

OVERVIEW

GOLDTM

& COMPACTTM

Page 2: GOLD Overview

2 Swegon reserves the right to alter specifications.

GOLD & COMPACT

Four unbeatable reasons why you should choose an air handling unit from Swegon.

►Economical control functionsA large number of functions, including communication, are integrated into the control system and are ready to be activated via a hand-held micro terminal. Several of the functions provide unique opportunities for saving energy.

►Fast installation and Plug-and-playThe work of installing the air handling units can be done quickly and easily and for the accessories, such as cooling units and air heaters, there are ready-to-use control functions and all connections are made using cables with quick-fit connectors. Plug-and-play!

►Saves spaceSwegon’s air handling units have compact dimensions and what’s more sharp duct bends can be connected directly to the air handling unit without pressure losses. This saves you space in the fan room.

►Optimum operating economyEnergy-saving fans, efficient heat recovery and full control of temperatures, airflows and operating times provide optimum operating economy.

PageGeneral Points - GOLD & COMPACT 2

GOLDTechnical description 5Complements and accessories 6Overview – Airflows 8Sizing - GOLD RX 9Sizing - GOLD PX 13Sizing - GOLD CX 14Sizing - GOLD SD 16Sizing - GOLD LP 18

Page

COMPACTTechnical description 19Complements and accessories 20Overview – Airflows 21

Sizing - COMPACT Unit 22Sizing - COMPACT Top 22Sizing - COMPACT Air 23Sizing - COMPACT Heat 23

Contents

Page 3: GOLD Overview

3Swegon reserves the right to alter specifications.

GOLD & COMPACT

With the focus on energy efficiencyEnergy-efficient fans of international calibre! Swegon’s fans are of the new generation of energy-efficient fans.

The motors are of EC type and have been developed on a new platform that offers the best energy efficiency on the market. Swegon’s EC motors can achieve a peak efficiency of more than 90%. This is more than 10 percentage units better than tradi-tional AC motors with frequency inverters and the difference becomes greater the more the speed of rotation is regulated to decelerate.

Every improvement in motor efficiency can be directly translated into a reduction in operating costs.

What’s more, the fan impellers also have a new design for an even more energy-efficient transport of air and the fan impeller sizes are optimised in relation to the air handling unit sizes.

Plug-and-play saves time and moneyFast installation, limited space requirement and Plug-and-play type accessories connection mean low installation costs.

Here are a few examples:

• The air handling units are complete with direct-driven supply air and extract air fans, supply air and extract air filters, heat exchanger and built-in control equipment.

• The air handling units have short installation length and are easy to handle at the building site. If needed, they can be simply split into sections for transport within the site. The cables between the sections have quick-fit connectors.

• The air handling units take up little space and the fans are designed to manage sharp duct bends arranged directly from the unit without pressure losses. Several of the air handling units can also be ordered with top-mounted duct connection spigots.

• Quick-fit connectors are used for connecting the hand-held micro terminal, supply air temperature sensor, air heater and communication. Other accessories and external functions are connected to an easily accessible row of wiring terminals.

Optimized heat recovery and cooling energy recoverySwegon’s rotary heat exchangers (GOLD RX/LP, COMPACT) offer unbeatable temperature efficiency, up to 85%, and low pressure drop. The rotary heat exchanger recovers cooling energy just as efficiently and with hygroscopic treatment it also recovers mois-ture. This reduces the costs for cooling equipment.

However, in some applications, the airflow paths through the heat exchanger must be completely separate from one another. Such applications call for the use of a plate heat exchanger (GOLD PX) or coil heat exchangers (GOLD CX/SD) as alternatives. Both have an effective freeze protection function that measures both the temperature and the humidity, which provides high efficiency.

Swegon’s heat exchangers cut your costs of operating the heat-ing and cooling system of the building to optimally low levels.

Example of a space-saving and compact installation of GOLD with cooling unit

Page 4: GOLD Overview

4 Swegon reserves the right to alter specifications.

GOLD & COMPACT

IQnomic is an intelligent economist

Examples of communication via the built-in web page with dynamic flow diagram (to the left) and log (above).

All the settings and readings can be entered/viewed in plain text via a user-friendly, hand-held micro terminal.

GOLD has a complete control system (IQnomic Premium) which also can be used for system-based functions, e.g. the control of zones and water circuits. For the COMPACT and GOLD LP units, the control system (IQnomic Standard) is designed for the smaller air handling units.

The integrated the IQnomic control system can be used for controlling pressures, airflows, temperatures, energy recovery and running times. Several unique energy-saving functions such as cooling boost, density-corrected airflow and season-related airflow are ready to be activated.

All the settings and readings can be entered/viewed in plain text via a user-friendly, hand-held micro terminal. The hand-held micro terminal is incorporated into the front door of the COM-PACT Air and Heat units.

The air handling unit can be automatically controlled in several different ways via the integrated time switch; however it can also be demand-controlled via a pressure sensor, presence detec-tor or an air quality sensor. Manual control is also possible.

Ready for communicationIQnomic has support for all the customary communication standards. The IQnomic also has a built-in web page ready to be connected to the network via cable and modem. All you need is an ordinary computer connected to the network.

IQnomic saves you moneyIQnomic offers great opportunities for economic operation with a large number of functions and complete control of tempera-tures, airflows and running times.

Moreover the installation and investment costs will be substan-tially lower when you compare these with the costs of planning, procuring, programming, configuring and installing conventional control components and supervisory systems.

Tip!

Try out the built-in web page with demo version at www.swegon. com/Products/Air handling units!

Page 5: GOLD Overview

5Swegon reserves the right to alter specifications.

GOLD

The GOLD RX/PX/CX/LP one-piece units are complete air han-dling units with direct-driven supply air and extract air fans, supply air and extract air filters and heat exchanger. The heat exchanger is either a rotary heat exchanger (RX/LP), plate heat exchanger (PX) or coil heat exchangers (CX). The GOLD SD single-direction units are supply air/extract air handling units with one direct-driven supply air or extract air fan. Optional filters are available for all sizes. Coil heat exchang-ers and unmounted pipework packages can be selected for the size 12-120 units.The casing is composed of cover panels and inspection doors. The exterior colour of the GOLD RX/PX/CX/SD is beige (NCS S2005-Y30R) and that of the GOLD LP is white (NCS S0502-G).The GOLD has built-in control equipment that can be operated from the hand-held micro terminal with plain-text display or via communication.The electrical and control system is completely integrated into the air handling unit. The microprocessor-based equipment con-trols and regulates temperatures, airflows and other functions. A large number of functions are built into the system and are simple to activate. If additional functional sections such as dampers and air coolers are required, they can be installed in the ductwork (uninsulated duct accessories) or can be docked directly to the air handling unit (insulated duct accessories).

ApplicationThe GOLD units are designed for use in comfort ventilation applications. Depending on the variant selected, GOLD units can be utilised in buildings such as office buildings, schools, day nurseries, public buildings, shops, residential buildings, etc.GOLD units equipped with plate/coil heat exchanger (PX/CX) and separate supply air and extract air handling units (SD) can also be used for the ventilation of moderately humid buildings; however not where the humidity is continuously high, such as in indoor water parks.The separate GOLD supply air and extract air handling units (SD) are designed for applications in which the supply air and extract air flows need to be completely separated from one another or where, due to limited available space, separate units for supply air and extract air are needed. They can also be used individually if only one of the variants is needed. The GOLD RX/PX/CX/SD units can be installed outdoors and then must be equipped with the following accessories: roof, air intake section and exhaust air hood.The GOLD is designed and tested for temperatures, in the sur-roundings and the air stream, from -40°C to +40°C.

CertificationSwegon AB has a certificated Quality Management System that conforms to ISO 9001 and an Environmental Management System that conforms to ISO 14001 Standards. The GOLD Air Handling System is also certificated by Eurovent.

General Points - GOLD

Technical Description

www.eurovent-certification.com www.certiflash.com

N° 06.06.319 Range: GOLD

GOLD CX

GOLD SD

GOLD RX

GOLD PX

GOLD LP

Page 6: GOLD Overview

6 Swegon reserves the right to alter specifications.

GOLD

The air recirculation section is available for the size 12 and larger GOLD RX, PX and CX units. The air recirculation section consists of an extra unit section that has a motor-driven damper (on/off or modulating). Depending on how the air recirculation section is to be used, extra sensors may also be required for reading the pressure, room temperature or CO2 content, heating and/or cooling coil temperatures and the status of shut-off dampers for exhaust air and outdoor air.

Air recirculation section, GOLD RX/PX/CXComplements and Accessories

Outdoor air hood Exhaust air hood Dual-purpose hood

• Outdoor air hood, sizes 04-40.

• Exhaust air hood, sizes 04-40.

• Dual-purpose hood, sizes 04/05 and 08.

• Exterior wall hood, sizes 04/05 and 08.

Hoods, GOLD

Exterior wall hood

The GOLD RX/PX/CX/SD units can be installed out-doors with the following accessories: roof, air intake section and exhaust air hood.

The roof is supplied in kit form, complete with the necessary assembly parts and sealing strips. Visible parts are made of sheet steel, painted in a beige colour tone, NCS S2005-Y30R.

Roofs cannot be used on air handling units with top air connection spigots.

Outdoor installation, GOLD

GOLD air handling units with roof and insulated duct accessories.

Duct accessories, GOLDFor a complete installation, there are duct accessories such as dampers, air heater för pre- and reheat, air cooler, prefilter and sound attenuator.

As alternatives, most of the duct accessories are pro-vided for connection with full cross sectional area, i.e. Full face. This reduces pressure losses, which saves electric power supplied to the fans. The accessories for Full face are integrated into an insulated casing, which reduces the installation costs and facilitates installation outdoors.

Examples of insulated duct accessories and Full face connection

Examples of uninsulated duct accessories

Page 7: GOLD Overview

7Swegon reserves the right to alter specifications.

GOLD

COOL DX Cooling unit The COOL DX is a complete cooling system for comfort cooling.

The COOL DX is internally fully wired, charged with refrigerant and the unit is trial run.

The cooling unit can be docked to the GOLD or it can be installed as a stand-alone unit. Only an electric power supply and a com-munication cable (with quick-fit connector) between the Cool DX and the GOLD are required. Plug-and-play!

Plug-and-play, air-to-air cooling units, GOLDComplements and Accessories

COOL DX GOLD

COOL DX

Best energy classSwegon has a complete program of cool-ing units and heat pumps for the produc-tion of chilled or hot water.

The units are energy efficient and con-form to the best energy class. They are certified by Eurovent.

They are available in several different versions and in various sizes and are designed for outdoor installation.

Air/water cooling units and heat pumps, GOLD

TETRIS, reversible cooling unit

OMICRON S, multi-functional cooling unit&heat pump

TAU, reversible heat pump

Page 8: GOLD Overview

8 Swegon reserves the right to alter specifications.

GOLD

Length

Width

Height(including junction hood and base beams)

Overview – Airflows, GOLD

All the sizing data specified in this bro-chure are meant for use as an overview. Exact sizing can be carried out in the web-based ProUnit air handling unit selection software.

Contact your nearest Swegon repre-sentative for data calculations or use the program yourself at www.swegon.com.

Outdoor air Supply air Extract air Exhaust air

Arrows for airflows in this brochure

Dimensions specified in this brochure

All the air handling units as from size 12 can be divided into sections for transport within the building site.

The length of the longest section is given in the dimension tables.

Division at the building site

Supplied with or without end wall panel.

The air handling unit can be ordered with-out end connection panel for the required direction of airflow and with insulated duct accessories that are designed for Full face connection.

Without end wall panel

With end wall panel

1) Applies to airflow regulation. If pressure regulation is used, the airflow can be regulated to zero, however this presupposes a certain static pressure drop in the ducting (approx. 50 Pa). 2) Whenever applicable, the value specified for cap. variant 1 applies.3) Heat exchanger, MPE/MTE

Sizing

GOLDRX

Min. 1) SFPv 2.0 at 200 Pa 2) Max.

m3/s m3/h m3/s m3/h m3/s m3/h04 0.08 290 0.42 1510 0.45 162005 0.08 290 0.42 1510 0.65 234008 0.20 720 0.78 2800 1.00 360012 0.20 720 1.19 4280 1.40 504014 0.30 1080 1.65 5940 1.65 594020 0.30 1080 1.80 6480 2.10 756025 0.50 1800 2.42 8710 2.50 900030 0.50 1800 2.42 8710 3.20 1152035 0.75 2700 3.82 13750 3.90 1404040 0.75 2700 3.82 13750 5.00 1800050 1.00 3600 5.00 18000 5.00 1800060 1.00 3600 5.05 18180 6.50 2340070 1.50 5400 7.00 25200 7.50 2700080 1.50 5400 7.00 25200 9.50 34200

100 2.50 9000 10.4 37440 11.0 39600120 2.50 9000 10.4 37440 14.0 50400

GOLDPX

Min. 1) SFPv 2.0 at 200 Pa 2) Max.

m3/s m3/h m3/s m3/h m3/s m3/h04 0.08 290 0.45/0.45 3) 1620/1620 3) 0.45 162005 0.08 290 0.62/0.50 3) 2230/1800 3) 0.65 234007 0.08 290 0.75/0.71 3) 2700/2560 3) 0.75 270008 0.20 720 0.97/0.79 3) 3490/2840 3) 1.00 360011 0.20 720 1.10/1.01 3) 3960/3640 3) 1.10 396012 0.20 720 1.40/1.14 3) 5040/4100 3) 1.40 504014 0.30 1080 1.65 5940 1.65 594020 0.30 1080 1.95 7020 2.10 756025 0.50 1800 2.50 9000 2.50 900030 0.50 1800 2.75 9900 3.20 11520

GOLDCX

Min. 1) SFPv 2.0 at 200 Pa 2) Max.

m3/s m3/h m3/s m3/h m3/s m3/h35 0.75 2700 3.90 14040 3.90 1404040 0.75 2700 4.25 15300 5.00 1800050 1.00 3600 5.00 18000 5.00 1800060 1.00 3600 6.00 21600 6.50 2340070 1.50 5400 7.50 27000 7.50 2700080 1.50 5400 8.00 28800 9.50 34200

100 2.50 9000 11.0 39600 11.0 39600120 2.50 9000 11.7 42120 14.0 50400

GOLDSD

Min. 1) SFPv 1.0 at 200 Pa 2) Max.

m3/s m3/h m3/s m3/h m3/s m3/h

Fan+Filter04 0.08 290 0.59 2120 0.60 216005 0.08 290 0.72 2590 0.80 288008 0.20 720 1.11 4000 1.20 4320

Fan+Filter+Coil heat exch. SFPv 2.0 at 200 Pa 2)

12 0.20 720 1.20 4320 1.80 648014 0.30 1080 1.76 6340 2.00 720020 0.30 1080 2.14 7700 2.80 1008025 0.50 1800 2.70 9720 3.20 1152030 0.50 1800 3.15 11340 4.00 1440035 0.75 2700 4.10 14760 5.00 1800040 0.75 2700 4.60 16560 6.00 2160050 1.00 3600 5.40 19440 6.00 2160060 1.00 3600 6.40 23040 8.00 2880070 1.50 5400 7.50 27000 9.00 3240080 1.50 5400 7.70 27720 12.0 43200100 2.50 9000 11.3 40680 14.0 50400120 2.50 9000 11.7 42120 18.0 64800

GOLDLP

Min. 1) SFPv 2.0 at 200 Pa Max.

m3/s m3/h m3/s m3/h m3/s m3/h05 0.08 290 0.41 1470 0.53 190008 0.08 290 0.62 2230 0.74 2600

Page 9: GOLD Overview

9Swegon reserves the right to alter specifications.

GOLD

GOLD RX, sizes 04/05, 08

Right-hand version

Left-hand version

Duct connection options A: Specify left-hand or right-hand version when placing orders. If the air handling unit is supplied with all the end connec-tion panels, the version can be changed at the building site by making a simple adjustment in the control equipment.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The air handling unit can be installed upended.

Base beams/Stand/FoundationIf the air handling unit is installed horizontally, it must be mounted on base beams (optional), a stand (accessory) or some other form of foundation so that it will be possible to open its inspection doors.

GOLDRXsize

Lengthmm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/sPower connection

Min SFPv 2.0

at 200 PaMax

04 1500 825 1020 243 Ø 315 0.08 0.42 0.45 1x230V, 10A or3x400V, 10A

05 1500 825 1020 243 Ø 315 0.08 0.42 0.65 1x230V, 101)/162)A or3x400V, 10A

08 1600 995 1185 309 Ø 400 0.20 0.78 1.00 1x230V, 16A1) or3x400V, 10A1)2)

GOLD RX Top, sizes 04/05, 08Duct connection options A: The GOLD is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by making a simple adjustment in the control equipment.

Base beams/Stand/FoundationIf the air handling unit is installed horizontally, it must be mounted on base beams (optional), a stand (accessory) or some other form of foundation so that it will be possible to open its inspection doors.

GOLDRX Top

size

Lengthmm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/sPower connection

Min SFPv 2.0

at 200 PaMax

04 1500 825 1020 247 Ø 315 0.08 0.40 0.45 1x230V, 10A or3x400V, 10A

05 1500 825 1020 247 Ø 315 0.08 0.40 0.65 1x230V, 10A or3x400V, 10A

08 1600 995 1185 310 Ø 400 0.20 0.721) 1.00 1x230V, 16A or3x400V, 10A

1) 0.72 m3/s refers to air handling units in the right-hand version. For air handling units in the left-hand version, the value is 0.77 m3/s.

Right-hand versionLeft-hand version

Sizing

1) Capacity variant 1 2)Capacity variant 2

Page 10: GOLD Overview

10 Swegon reserves the right to alter specifications.

GOLD

GOLD RX, size 12

Duct connection optionsA: Specify left-hand or right-hand version when placing orders. If the air handling unit is supplied with all the end connec-tion panels, the version can be changed at the building site by making a simple adjustment in the control equipment.

B: Specify with or without end wall panel for each airflow direction when placing orders.

C: The arrangement of the functional sections can be verti-cally reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders.

Right-hand version

Left-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 1 Fan arrangement 2

GOLDRXsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

12 1860 655 1199 1495 518 Ø 500 0.20 1.19 1.40 3x400V, 10A

GOLD RX Top, size 12

Duct connection optionsA: The GOLD is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by making a simple adjustment in the control equipment.

Right-hand versionLeft-hand version

GOLDRX Top

size

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

12 1860 655 1199 1495 504 Ø 500 0.20 1.051) 1.40 3x400V, 10A

1) 1.05 m3/s refers to air handling units in the right-hand version. For air handling units in the left-hand version, the value is 1.08 m3/s.

Sizing

Page 11: GOLD Overview

11Swegon reserves the right to alter specifications.

GOLD

* *

* *

Duct connection optionsA: Specify left-hand or right-hand version when placing orders. If the air handling unit is supplied with all the end connec-tion panels, the version can be changed at the building site by making a simple adjustment in the control equipment.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders.

D: Specify upper fan outlet for upward air discharge when plac-ing orders (not for outdoor units).

E: Specify air intake from above for outdoor air or extract air when placing orders (sizes 14-30, not for outdoor units).

Right-hand version

Left-hand version* Sizes 14-30

Fan arrangement 1 Fan arrangement 2

Fan arrangement 1 Fan arrangement 2

GOLD RX sizes 14/20, 25/30, 35/40

GOLDRXsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

14 2080 765 1400 1595 625 1000x400 0.30 1.65 1.65 3x400V, 10A

20 2080 765 1400 1595 625 1000x400 0.30 1.80 2.10 3x400V, 101)/162)A

25 2220 835 1600 1795 786 1200x500 0.50 2.42 2.50 3x400V, 16A

30 2220 835 1600 1795 786 1200x500 0.50 2.42 3.20 3x400V, 20A

35 2446 948 1990 2185 1120 1400x600 0.75 3.82 3.90 3x400V, 16A

40 2446 948 1990 2185 1120 1400x600 0.75 3.82 5.00 3x400V, 25A

Sizing

1) Capacity variant 1 2)Capacity variant 2

Page 12: GOLD Overview

12 Swegon reserves the right to alter specifications.

GOLD

GOLD RX, sizes 50/60 and 70/80Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders.

D: Specify upper fan outlet for upward air discharge when plac-ing orders (not for outdoor units).

DeliveryThe GOLD RX 70/80 units are supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section in which the fan is placed in the lower level.

Right-hand version

Left-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 1 Fan arrangement 2

GOLDRXsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

50 2670 1050 2318 2353 1498 1600x800 1.00 5.00 5.00 3x400V, 25A

60 2670 1050 2318 2353 1498 1600x800 1.00 5.05 6.50 3x400V, 321)/502)A

70 3120 1275 2637 2740 2311 1800x1000 1.50 7.00 7.50 3x400V, 32A

80 3120 1275 2637 2740 2311 1800x1000 1.50 7.00 9.50 3x400V, 501)/802)A

GOLD RX, sizes 100/120

Sizing

Right-hand version

Left-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 1 Fan arrangement 2

GOLDRXsize

Lengthmm

The longest sec-tion when sec-

tionalizingmm

Widthmm

Heightmm

Weightkg

Ductconnection3)

mm

Airflow, m3/s

Power connectionMin

SFPv 2.0 at 200 Pa

Max

100 3322 1126 3340 3440 3982 2400x1200 2.5 10.4 11.0 3x400V, 50A

120 3322 1126 3340 3440 3982 2400x1200 2.5 10.4 14.0 3x400V, 801)/1252)A1) Capacity variant 1. 2) Capacity variant 2. 3) The dimensions of the duct connection on the units with a fan outlet for upward air discharge are 2500 x 800 mm.

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders.

D: Specify upper fan outlet for upward air discharge when plac-ing orders (not for outdoor units).

DeliveryThe GOLD RX 100/120 air handling units are delivered in five separate subunits: two fan sections, two filter sections and one heat exchanger section. The heat exchanger section can also be supplied split into two casing sections and rotor, in which case the rotor is supplied tilted in a transport cradle (transport height = 2930 mm). After assembling the heat exchanger section, install the five units at the building site.

1) Capacity variant 1. 2) Capacity variant 2.

Page 13: GOLD Overview

13Swegon reserves the right to alter specifications.

GOLD

GOLD PX, sizes 04/05, 07/08

GOLD PX, size 11/12

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: Specify air intake from above for supply air and/or extract air when placing orders (not for outdoor units).

GOLD PX, sizes 14/20 and 25/30

Right-hand versionLeft-hand version

Right-hand versionLeft-hand version

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders. Right-hand versionLeft-hand version

GOLDPX

size

Lengthmm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower connection

Min SFPv 2.0 for 200 Pa Max

04 2000 905 1200 291-337 Ø 315 0.08 0.45/0.45 3) 0.45 1x230V, 10A or3x400V, 10A

05 2000 905 1200 291-337 Ø 315 0.08 0.62/0.50 3) 0.65 1x230V, 101)/162)A or3x400V, 10A

07 2230 1075 1365 360-419 Ø 400 0.08 0.75/0.71 3) 0.75 1x230V, 101)/162)A or3x400V, 10A

08 2230 1075 1365 369-428 Ø 400 0.20 0.97/0.79 3) 1.00 1x230V, 16A1) or3x400V, 10A1)2)

GOLDPX

size

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

14 2830 1300 1480 1595 764 1000x400 0.30 1.65 1.65 3x400V, 10A

20 2830 1300 1480 1595 764 1000x400 0.30 1.95 2.10 3x400V, 101)/162)A

25 3170 1500 1680 1795 1002 1200x500 0.50 2.50 2.50 3x400V, 16A

30 3170 1500 1680 1795 1002 1200x500 0.50 2.75 3.20 3x400V, 161)/202)A

GOLDPX

size

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

for 200 PaMax

11 2510 1200 1279 1495 552-646 Ø 500 0.20 1.10/1.01 3) 1.101x230V, 16A1) or3x400V, 10A1)2)

12 2510 1200 1279 1495 574-668 Ø 500 0.20 1.40/1.14 3) 1.40 3x400V, 10A

Sizing

1) Capacity variant 1 2)Capacity variant 2 3)Heat exchanger, MPE/MTE

1) Capacity variant 1 2)Capacity variant 2

1) Capacity variant 1 2)Capacity variant 2 3)Heat exchanger, MPE/MTE

Page 14: GOLD Overview

14 Swegon reserves the right to alter specifications.

GOLD

Right-hand version

Left-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 1 Fan arrangement 2

GOLD CX, size 35/40

GOLDCXsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm3)

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

35 2575 948 2590 2085 1355 1400x600 0.75 3.90 3.90 3x400V, 20A

40 2575 948 2590 2085 1355 1400x600 0.75 4.25 5.00 3x400V, 32A

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders.

D: Specify upper fan outlet for upward air discharge when plac-ing orders (not for outdoor units).

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when placing orders.

D: Specify upper fan outlet for upward air discharge when plac-ing orders (not for outdoor units).

DeliveryThe GOLD CX 70/80 units are supplied as two units. The one unit consists of the centre section with heat exchanger and the fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section in which the fan is placed in the lower level.

GOLDCXsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm3)

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower connection

Min SFPv 2.0

at 200 PaMax

50 2860 1050 2968 2353 2045 1600x800 1.00 5.00 5.00 3x400V, 25A

60 2860 1050 2968 2353 2045 1600x800 1.00 6.00 6.50 3x400V, 401)/502)A

70 3310 1275 3437 2740 3030 1800x1000 1.50 7.50 7.50 3x400V, 32A

80 3310 1275 3437 2740 3030 1800x1000 1.50 8.00 9.50 3x400V, 501)/802)A

GOLD CX, sizes 50/60 and 70/80

Right-hand version

Left-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 1 Fan arrangement 2

Sizing

1) Capacity variant 1 2)Capacity variant 2 3) Including pipework package

3) Including pipework package

Page 15: GOLD Overview

15Swegon reserves the right to alter specifications.

GOLD

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify with or without end wall panel for each airflow direc-tion when placing orders.

C: The arrangement of the functional sections can vary. To be specified when ordering as fan arrangement 1, 2, 4 or 5. For fan arrangement 4 and 5, you should also specify: supply air in upper or lower level.

D: Specify upper fan outlet for upward air discharge when plac-ing orders (not for outdoor units).

DeliveryThe GOLD RX 100/120 air handling units are delivered in six separate subunits: two fan sections, two filter sections and two heat exchanger sections. The six sections must be fitted together at the building site. The pipework package including the control box can be ordered as accessories and are supplied in unassem-bled condition for wall or floor mounting.

GOLD CX, size 100/120Sizing

GOLDCXsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Duct connection

mm4)

Airflow, m3/sPower connection

Min SFPv 2.0

at 200 PaMax

100 3322 1126 3340 3440 4568 2400x1200 2.5 11.0 11.0 3x400V, 50A

120 3322 1126 3340 3440 4568 2400x1200 2.5 11.7 14.0 3x400V, 801)/1252)A

1) Capacity variant 1. 2) Capacity variant 2. 4) The dimensions of the duct connection on the units with a fan outlet for upward air discharge are 2500 x 800 mm.

Right-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 5, supply air – upper level

Fan arrangement 5, supply air - lower level

Left-hand version

Fan arrangement 1 Fan arrangement 2

Fan arrangement 4, supply air – upper level

Fan arrangement 4, supply air - lower level

Page 16: GOLD Overview

16 Swegon reserves the right to alter specifications.

GOLD

Installation/duct connection optionsA: The air handling unit can be upended or turned upside down. The unit can also be installed with the inspection door upward, but not downward.

B: Specify: with or without end connection panel when placing orders.

Base beams/Stand/FoundationIf the air handling unit is installed horizontally, it must be mounted on base beams (optional), a stand (accessory) or some other form of foundation so that it will be possible to open its inspection doors.

GOLD SD, sizes 04/05, 08

GOLDSDsize

Lengthmm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/s Power connectionMin SFPv 1.0 for 200 Pa Max

Fan + Filter

04 1099 825 490 119 Ø 315 0.08 0.59 0.60 1x230V, 10A

05 1099 825 490 119 Ø 315 0.08 0.72 0.80 1x230V, 10A

08 1174 995 575 137 Ø 400 0.20 1.11 1.20 1x230V, 10A1)

3x400V, 10A2)

Sizing

GOLD SD, size 12

Fan with filter, if required

Right-hand versionLeft-hand version

Fan with filter, if required + Coil heat exchanger in extract

air. Droplet eliminator is optional.

Fan with filter, if required + Coil heat

exchanger in supply air.

Duct connection optionsA: Specify left-hand or right-hand version when ordering.

B: Specify: with or without end connection panel when placing orders.

GOLDSDsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

Fan + Filter + Coil heat exchanger

12 1961 1404 1199 748 306 Ø 500 0.20 1.20 1.80 3x400V, 10A

1) Capacity variant 1 2)Capacity variant 2

Page 17: GOLD Overview

17Swegon reserves the right to alter specifications.

GOLD

Sizing

Duct connection optionsA: Specify left-hand or right-hand version when placing orders.

B: Specify: with or without end connection panel when placing orders.

C: Specify fan outlet for upward air discharge when placing orders (not applicable to outdoor units).

DeliveryThe size 70/80 GOLD SD units are always supplied as one unit if they each consist of a fan or fan + filter. If it consists of fan + filter + coil heat exchanger, it is supplied as two units.

The GOLD SD 100/120 units are supplied as separate units for fan + filter + coil heat exchanger.

Units in the other sizes are always supplied as one unit.

Fan

Fan + Filter

Fan + Filter + Coil heat exchanger

in extract air. The droplet collector is an

accessory.

Fan + Filter + Coil heat exchanger in

supply air

Right-hand versionLeft-hand version

GOLD SD, sizes 14/20,25/30,35/40,50/60,70/80, 100/120

GOLDSDsize

Lengthmm

The longest section when sectionalizing

mm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower

connectionMin SFPv 2.0

at 200 PaMax

Fan + Filter + Coil heat exchanger

14 2471 988 1400 906 473 1000x400 0.30 1.76 2.00 3x400V, 10A

20 2471 988 1400 906 473 1000x400 0.30 2.14 2.80 3x400V, 10A

25 2576 1093 1600 1126 611 1200x500 0.50 2.70 3.20 3x400V, 10A

30 2576 1093 1600 1126 611 1200x500 0.50 3.15 4.00 3x400V, 10A

35 2576 1093 1990 1226 782 1400x600 0.75 4.10 5.00 3x400V, 10A

40 2576 1093 1990 1226 782 1400x600 0.75 4.60 6.00 3x400V, 16A

50 2543 1050 2318 1420 1080 1600x800 1.00 5.40 6.00 3x400V, 10A

60 2543 1050 2318 1420 1080 1600x800 1.00 6.40 8.00 3x400V, 161)/252)A

70 3310 1327 2637 1420 1672 1800x1000 1.50 7.50 9.00 3x400V,16A

80 3310 1327 2637 1420 1672 1800x1000 1.50 7.70 12.0 3x400V, 251)/402)A

100 3322 1126 3340 1720 2284 2400x12003) 2.5 11.3 14.0 3x400V, 25A

120 3322 1126 3340 1720 2284 2400x12003) 2.5 11.7 18.0 3x400V, 401)/632)A

1) Capacity variant 1 2)Capacity variant 23) The dimensions of the duct connection on the units with a fan outlet for upward air discharge are 2500 x 800 mm.

Page 18: GOLD Overview

18 Swegon reserves the right to alter specifications.

GOLD

Sizing

GOLD LP, sizes 05, 08Right-hand version

Left-hand version

Installation/duct connection optionsA: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by making a simple adjustment in the control equipment.

InstallationThanks to its low installation height, the GOLD LP can be installed in false ceiling voids, horizontally in an attic space or in other confined spaces. In order to save floor space, the GOLD LP can also be mounted by a wall (a floor stand is available as an accessory) as an alternative to a conventional unit arrangement. If the unit is mounted on a wall, the electric equipment cubicle must always be located upwards.

GOLDLP

size

Lengthmm

Width 11)

mmWidth 2

mmHeight

mmWeight

kg

Duct connection

mm

Airflow, m3/sPower

connectionMinSFPv 2.0 at 200 Pa

Max

05 2172 507 560 1171 247 454x400 0.08 0.41 0.53 1x230V, 10A

08 2370 582 635 1329 301 533x475 0.08 0.62 0.74 3x400V, 10A

1) Refers to the width with the slide rails for the inspection doors removed.

Visible on the ceiling In a corridor

In a closet

Installation Examples

In suspended ceilings

Page 19: GOLD Overview

19Swegon reserves the right to alter specifi cations.

COMPACT

The COMPACT units are a complete air handling units with direct-driven supply air and extract air fans, supply air and extract air fi lters, and rotary heat exchanger.

The exterior colour of the visible sheet metal surfaces is white, (NCS S0502-G).

The COMPACT has built-in control equipment that can be oper-ated from the hand-held micro terminal with plain-text display. The electrical and control system is completely integrated into the air handling unit. The microprocessor-based equipment con-trols and regulates temperatures, airfl ows and other functions. A large number of functions, including communication, are built into the system and are simple to activate.

If supplementary functional sections such as dampers and air coolers are required, they must be installed in the ductwork.

ApplicationThe COMPACT Unit and COMPACT Top units are designed for comfort ventilation and can be used in small premises such as offi ces, schools, day nurseries, public premises, shops, residential buildings, etc. The space available in smaller buildings is usually restricted. The COMPACT Unit and COMPACT Top make a very compact installation possible. The COMPACT Unit AHUs have duct connection spigots on their end panels, the traditional way, whereas the COMPACT Top units have them at the top.

The COMPACT Air and COMPACT Heat units are designed for comfort ventilation and can be used in classrooms, day nurser-ies, conference halls, smaller offi ces, workrooms, shops, res-taurants and similar public premises. The COMPACT Air and COMPACT Heat can be installed directly in the room to be ventilated. COMPACT Heat operates in normal applications like COMPACT Air but it can also be used for heating the room with BOOSTER function.

The COMPACT units should be installed indoors.

The COMPACT units are designed and tested for ambient tem-peratures of from -25°C to +40°C, and air stream temperatures of from -40°C to +40°C.

Certifi cationSwegon AB has a certifi cated Quality Management System that conforms to ISO 9001 and an Environmental Management System that conforms to ISO 14001 Standards.TheCOMPACT Unit & Top air handling units are also certifi cated by Eurovent.

COMPACT Air

COMPACT Unit

COMPACT Top

General Points - COMPACT

Technical Description

www.eurovent-certifi cation.com www.certifl ash.com

N° 09.05.426 Range: COMPACT

COMPACT Heat

Page 20: GOLD Overview

20 Swegon reserves the right to alter specifi cations.

COMPACT

Duct accessories, COMPACT

Outdoor air hood Exhaust air hood Dual-purpose hood

• Outdoor air hood (Unit/Top)

• Exhaust air hood (Unit/Top)

• Dual-purpose hood (Unit/Top)

• Exterior wall hood

Hoods, COMPACT

Exterior wall hood

COMPACT control componentsIf necessary, the built-in control equipment can be supplemented with components e.g. the following:

• Air quality sensor

• Presence detector

• Room sensor

Duct accessories are available for a complete installation, e.g. the following:

• Damper

• Electric or hot water air heater

• Air cooler for water or direct expansion

• Sound attenuator

Air handling unit accessories, COMPACTAccessories are available for the various air handling models, e.g. the following:

• Stand (Unit)

• Door fastener (Unit)

• Extract air connection (Air/Heat)

• Cover plate between air handling unit and roof (Air/Heat)

• Louvre damper (Air, included as standard in the Heat model)

Air heater and air cooler

Damper

Electric air heater

Support stand

Extract air connection piece

Air quality sensor Presence detector

Louvre damper

Complements and Accessories

Page 21: GOLD Overview

21Swegon reserves the right to alter specifi cations.

COMPACT

Length

Width

Height(including junction hood)

Overview – Airfl ows, COMPACT

All the sizing data specifi ed in this bro-chure are meant for use as an overview. Exact sizing can be carried out in the web-based ProUnit air handling unit selection software.

Contact your nearest Swegon repre-sentative for data calculations or use the program yourself at www.swegon.com.

Outdoor air Supply air Extract air Exhaust air

Arrows for airfl ows in this brochure

Dimensions specifi ed in this brochure

Sizing

1) The sound pressure level with consideration given to a room effect of -12 dB. 2) Does not apply to operation in the BOOSTER mode.

Length

Width

Height(including base beams)

Length

Width

Height(including base beams)

Length

Width

Height(including base beams, air recirculation section and louvre damper)

COMPACTUnit

Min. SFPv 2.0 at 200 Pa Max.

m3/s m3/h m3/s m3/h m3/s m3/h02 0.08 290 0.2 720 0.23 830

03 0.08 290 0.25 900 0.36 1300

COMPACTTop

Min. SFPv 2.0 at 200 Pa Max.

m3/s m3/h m3/s m3/h m3/s m3/h02 0.08 290 0.2 720 0.23 830

03 0.08 290 0.23 830 0.36 1300

COMPACTAir

Min. Max./SFPV Sound level ≤ 30 dB(A) for airfl ow

m3/s m3/h m3/s m3/h m3/s m3/h02 0.08 290 0.23/1.1 830/1.1 0.231) 8301)

03 0.08 290 0.33/1.8 1190/1.8 0.251) 9001)

COMPACTHeat

Min. Max./SFPV Sound level ≤ 30 dB(A) for airfl ow

m3/s m3/h m3/s m3/h m3/s m3/h02 0.08 290 0.23/1.3 830/1.3 0.231)2) 8301)2)

03 0.08 290 0.305/2.0 1100/2.0 0.231)2) 8301)2)

Page 22: GOLD Overview

22 Swegon reserves the right to alter specifications.

COMPACT

Right-hand version

Left-hand version

Sizing

COMPACT Unit, sizes 02, 03Duct connection options A: The air handling unit is supplied in the right-hand version. The unit can be changed to the left-hand version at the building site by making a simple adjustment in the control equipment.

B: The air handling unit can be installed upended.

Base frame/BaseIf the air handling unit is installed horizontally, it must be mounted on a stand (accessory) or some other form of base sup-port, so that its inspection doors can be opened.

COMPACTUnitsize

Lengthmm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower connection

Min SFPv 2.0

at 200 PaMax

02 1214 788 872 160 Ø 250 0.08 0.2 0.23 1x230V, 10A

03 1214 788 872 160 Ø 250 0.08 0.25 0.36 1x230V, 10A

COMPACT Top, sizes 02, 03Duct connection options A: The air handling unit is produced in one variant in which all the components are arranged at their given physical locations inside the unit. All the duct connections are arranged from the top of the air handling unit.

Base frame/BaseThe unit is equipped with base beams.

COMPACTTopsize

Lengthmm

Widthmm

Heightmm

Weightkg

Duct connection

mm

Airflow, m3/sPower connection

Min SFPv 2.0

at 200 PaMax

02 1103 788 1302 200 Ø 250 0.08 0.2 0.23 1x230V, 10A

03 1103 788 1302 200 Ø 250 0.08 0.23 0.36 1x230V, 10A

Page 23: GOLD Overview

23Swegon reserves the right to alter specifications.

COMPACT

Sizing

COMPACT Air, sizes 02, 03Duct connection options A: The air handling unit is produced in one variant in which all the components are arranged at their given physical locations inside the unit. All the duct connections are arranged from the top of the air handling unit.

InstallationThe air diffuser section can be separated from the main unit section for transport within the building site.

The unit should be installed in the room to be ventilated and its electric plug should be connected to an earthed mains electric socket. The ducts for outdoor air and exhaust air should be connected to the top of the unit and should be arranged to lead out through the wall.

COMPACTAirsize

Lengthmm

Widthmm

Heightmm

Weightkg

Ductconnection

mm

Airflow, m3/s Available pressure for outdoor air/exhaust air at max. airflow

Pa

Sound level

≤ 30 dB(A) at m3/s

Power connectionMin Max/SFPv

02 1102 788 2114 331 Ø 250 0.08 0.23/1.1 20 0.231) 1x230V, 10A

03 1102 788 2114 331 Ø 250 0.08 0.33/1.8 20 0.251) 1x230V, 10A

1) The sound pressure level with consideration given to a room effect of -12 dB.

COMPACT Heat, sizes 02, 03Duct connection options A: The air handling unit is produced in one variant in which all the components are arranged at their given physical locations inside the unit. All the duct connections are arranged from the top of the air handling unit.

InstallationThe air diffuser section can be separated from the main unit section for transport within the building site.

The unit should be installed in the room to be ventilated and should be connected to the mains power supply via a type Peri-lex electric plug to an appropriate power outlet. The ducts for outdoor air and exhaust air should be connected to the top of the unit and should be arranged to lead out through the wall.

COMPACTHeatsize

Lengthmm

Widthmm

Heightmm

Weightkg

Duct connec-tion mm

Airflow, m3/s Available pressure for outdoor air/exhaust air at max. airflow

Pa

Sound level

≤ 30 dB(A) at m3/s

Power connectionMin Max/SFPv

02 1102 788 2414 345 Ø 250 0.08 0.23/1.3 20 0.231)2) 3x400V, 16A

03 1102 788 2414 345 Ø 250 0.08 0.305/2.0 20 0.231) 2) 3x400V, 16A

1) The sound pressure level with consideration given to a room effect of -12 dB. 2) Does not apply to operation in the BOOSTER mode.

Page 24: GOLD Overview

www.swegon.com

Swegon can offer specifi c products in most product areas that deal with air treatment. However the end user will be most benefi ted by our products if they are supplied in the form of system solutions. We then take responsibility for seeing to it that the products are simple to install, save fl oor space and operate in harmony to provide the highest pos-sible degree of comfort and use the least possible amount of energy. Our control systems with open communication also save substantial costs otherwise spent on external control equipment.

Swegon personnel are there to help you with customised sys-tem solutions for specifi c applications to the extent required.

Swegon also offers complete platform solutions, Swegon Solutions.

All Swegon Solutions have interacting open-loop and closed-loop control functionality which can be used as a "Stand-alone" system, thanks to its built-in web pages, or can simply communicate with a main control system. These platforms not only make your sizing work simpler, they also substan-tially reduce the operating costs, thanks to the optimising of the pressure conditions in the system, demand-controlled airfl ows, the control of light fi xtures and the distribution of water, etc.

SwegonSolutionsTM

Swegon – The systems supplier!

Cooling unit&heat pumpmulti-functional unit Air handling unit

Air coolerAir heater

Climate beams and comfort modules

The air handling unit supplies free cooling when the temperature conditions allow it.Whenever cooling or heating is required, the multi-functional unit simultaneously supplies chilled water or

hot water to the air cooler, air heater and climate beams.

Example:

EN-G

OLD

/CO

MPA

CT

over

view

201

3-01

-22