Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in...
Transcript of Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in...
Go Small. THINK BIG.Provena™ Midline CatheterBy combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter* MST midlines that maintain high performance for infusion therapy.
*Comparison in relation to BD PowerMidline™ catheters
3 Fr single lumen6 mL/sec max flow rate
4 Fr dual lumen6 mL/sec max flow rate
Product Code Description
S4153118 Basic
S4153108 Full
S4153108G Full with GuardIVa® dressing
S4153108D Max Barrier
S4153108DG Max Barrier with GuardIVa® dressing
S4153108B Full with BioPatch™ dressing
S4153108BD Max Barrier with BioPatch™ dressing
S4153108BP Full+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides
S4153108BDP Max Barrier+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides
S4153108GP Full+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides
S4153108DGP Max Barrier+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides
Product Code Description
S4254118 Basic
S4254108 Full
S4254108G Full with GuardIVa® dressing
S4254108D Max Barrier
S4254108DG Max Barrier with GuardIVa® dressing
S4254108B Full with BioPatch™ dressing
S4254108BD Max Barrier with BioPatch™ dressing
S4254108BP Full+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides
S4254108BDP Max Barrier+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides
S4254108GP Full+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides
S4254108DGP Max Barrier+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides
Patients rely on you, the clinician, to help make them better. When determining the appropriate VAD, industry guidelines recommend selecting the configuration with the smallest outer diameter for the prescribed therapy.2
5 Fr DL Bard®
PowerMidline™catheter 7 ml/secmaximum flow
4 Fr DL Provena™Midline catheter6 ml/secmaximum flow
14%smaller outer diameter
98%intraluminal area maintained
18 Ga 18 Ga
Warning: Do not use the GuardIVa® dressing on patients with a known sensitivity to chlorhexidine gluconate. The use of chlorhexidine gluconate containing products has been reported to cause irritation, sensitization, and generalized allergic reactions. If any such reactions occur, discontinue use of the dressing immediately, and if severe, contact a physician.
*Depending on the kit ordered, these components will differ.
96” probe cover, elastic bands, and conductive gel
PinPoint™ GT needle guides* (0.5 – 2.0 cm depth coverage)
GuardIVa® antimicrobial hemostatic IV dressing*
BIOPATCH™ Protective Disk* with CHG
Additional saline syringe3 (number of lumens plus one)
Catheter trimmer Purell™ Advanced Instant Hand Sanitizer (x2)
ChloraPrep™ 3 mL applicator, clear (inside of wrap)
ChloraPrep™ 3 mL applicator, tinted (x2) (outside of wrap)
Textured tourniquet 3M™ Tegaderm™ I.V. Advanced Securement Dressing (1685)
StatLock® CV Plus stabilization device with fixed posts, tricot
Non-woven gauze
Max Barrier+ components
Indications for UseThe Provena™ Midline Catheters are indicated for short-term access to the peripheral venous system for selected intravenous therapies, blood sampling, and power injection of contrast media. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy and appropriateness of the procedure. The Provena™ Midline catheters are suitable for use with power injectors.
ContraindicationsThe device is contraindicated whenever:• The presence of device-related infection, bacteremia, or septicemia is known or suspected.• The patient’s body size is insufficient to accommodate the size of the implanted device.• The patient is known or is suspected to be allergic to materials contained in the device.• Local tissue factors and/or past treatment will prevent proper device stabilization and/or access.
3 Fr SL Provena™ Midline catheter 4 Fr DL Provena™ Midline catheter
Outer Diameter (Fr) 3 4
Lumen Size (Ga) 18 18/18
Max Power Injection Rate (mL/sec) 6 6
Reverse Taper Length (cm) 4 4
Max Achievable Pump Flow Rate^ (mL/hr) Saline (1.0 cP) >999.9TPN (2.0 cP) >999.9Blood (3.5 cP) = 868
Saline (1.0 cP) >999.9TPN (2.0 cP) >999.9Blood (3.5 cP) = 832
Gravity Flow Rate (mL/hr) 1,454 1,298
Priming Volume (mL) 0.34 0.35
^Estimates based on a pump alarm setting of 500 mmHg and a full-length catheter at 20 cm.
1 Comparison in relation to BD PowerMidline™ catheters 2 Infusion Nurses Society. “Infusion Therapy Standards of Practice.” Journal of Infusion Nursing. Volume 39. Jan/Feb 2016.3 Compared to standard BD® Maximal Barrier midline trays.Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions, and directions for use.
605 North 5600 WestSalt Lake City, Utah 84116 USAMain: 801-522-5000Customer Service: 1-800-545-0890 Clinical Information: 1-800-443-3385
BD, the BD Logo, GuardIVa, Pinpoint, PowerMidline, and Provena are trademarks of Becton, Dickinson and Company. All other trademarks are the property of their respective owners. © 2019 BD and its subsidiaries. All rights reserved. BAS/PRVMID/0319/0010
bardaccess.com