Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in...

4
Go Small. THINK BIG. Provena Midline Catheter By combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter* MST midlines that maintain high performance for infusion therapy. *Comparison in relation to BD PowerMidline catheters

Transcript of Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in...

Page 1: Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter*

Go Small. THINK BIG.Provena™ Midline CatheterBy combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter* MST midlines that maintain high performance for infusion therapy.

*Comparison in relation to BD PowerMidline™ catheters

Page 2: Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter*

3 Fr single lumen6 mL/sec max flow rate

4 Fr dual lumen6 mL/sec max flow rate

Product Code Description

S4153118 Basic

S4153108 Full

S4153108G Full with GuardIVa® dressing

S4153108D Max Barrier

S4153108DG Max Barrier with GuardIVa® dressing

S4153108B Full with BioPatch™ dressing

S4153108BD Max Barrier with BioPatch™ dressing

S4153108BP Full+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides

S4153108BDP Max Barrier+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides

S4153108GP Full+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides

S4153108DGP Max Barrier+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides

Product Code Description

S4254118 Basic

S4254108 Full

S4254108G Full with GuardIVa® dressing

S4254108D Max Barrier

S4254108DG Max Barrier with GuardIVa® dressing

S4254108B Full with BioPatch™ dressing

S4254108BD Max Barrier with BioPatch™ dressing

S4254108BP Full+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides

S4254108BDP Max Barrier+ with BioPatch™ dressing, probe cover and PinPoint™ GT needle guides

S4254108GP Full+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides

S4254108DGP Max Barrier+ with GuardIVa® dressing, probe cover and PinPoint™ GT needle guides

Patients rely on you, the clinician, to help make them better. When determining the appropriate VAD, industry guidelines recommend selecting the configuration with the smallest outer diameter for the prescribed therapy.2

5 Fr DL Bard®

PowerMidline™catheter 7 ml/secmaximum flow

4 Fr DL Provena™Midline catheter6 ml/secmaximum flow

14%smaller outer diameter

98%intraluminal area maintained

18 Ga 18 Ga

Page 3: Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter*

Warning: Do not use the GuardIVa® dressing on patients with a known sensitivity to chlorhexidine gluconate. The use of chlorhexidine gluconate containing products has been reported to cause irritation, sensitization, and generalized allergic reactions. If any such reactions occur, discontinue use of the dressing immediately, and if severe, contact a physician.

*Depending on the kit ordered, these components will differ.

96” probe cover, elastic bands, and conductive gel

PinPoint™ GT needle guides* (0.5 – 2.0 cm depth coverage)

GuardIVa® antimicrobial hemostatic IV dressing*

BIOPATCH™ Protective Disk* with CHG

Additional saline syringe3 (number of lumens plus one)

Catheter trimmer Purell™ Advanced Instant Hand Sanitizer (x2)

ChloraPrep™ 3 mL applicator, clear (inside of wrap)

ChloraPrep™ 3 mL applicator, tinted (x2) (outside of wrap)

Textured tourniquet 3M™ Tegaderm™ I.V. Advanced Securement Dressing (1685)

StatLock® CV Plus stabilization device with fixed posts, tricot

Non-woven gauze

Max Barrier+ components

Page 4: Go Small. THINK BIG. · Go Small. THINK BIG. Provena™ Midline Catheter By combining advances in polyurethane material technology and manufacturing processes, BD created smaller-diameter*

Indications for UseThe Provena™ Midline Catheters are indicated for short-term access to the peripheral venous system for selected intravenous therapies, blood sampling, and power injection of contrast media. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy and appropriateness of the procedure. The Provena™ Midline catheters are suitable for use with power injectors.

ContraindicationsThe device is contraindicated whenever:• The presence of device-related infection, bacteremia, or septicemia is known or suspected.• The patient’s body size is insufficient to accommodate the size of the implanted device.• The patient is known or is suspected to be allergic to materials contained in the device.• Local tissue factors and/or past treatment will prevent proper device stabilization and/or access.

3 Fr SL Provena™ Midline catheter 4 Fr DL Provena™ Midline catheter

Outer Diameter (Fr) 3 4

Lumen Size (Ga) 18 18/18

Max Power Injection Rate (mL/sec) 6 6

Reverse Taper Length (cm) 4 4

Max Achievable Pump Flow Rate^ (mL/hr) Saline (1.0 cP) >999.9TPN (2.0 cP) >999.9Blood (3.5 cP) = 868

Saline (1.0 cP) >999.9TPN (2.0 cP) >999.9Blood (3.5 cP) = 832

Gravity Flow Rate (mL/hr) 1,454 1,298

Priming Volume (mL) 0.34 0.35

^Estimates based on a pump alarm setting of 500 mmHg and a full-length catheter at 20 cm.

1 Comparison in relation to BD PowerMidline™ catheters 2 Infusion Nurses Society. “Infusion Therapy Standards of Practice.” Journal of Infusion Nursing. Volume 39. Jan/Feb 2016.3 Compared to standard BD® Maximal Barrier midline trays.Please consult product labels and inserts for any indications, contraindications, hazards, warnings, precautions, and directions for use.

605 North 5600 WestSalt Lake City, Utah 84116 USAMain: 801-522-5000Customer Service: 1-800-545-0890 Clinical Information: 1-800-443-3385

BD, the BD Logo, GuardIVa, Pinpoint, PowerMidline, and Provena are trademarks of Becton, Dickinson and Company. All other trademarks are the property of their respective owners. © 2019 BD and its subsidiaries. All rights reserved. BAS/PRVMID/0319/0010

bardaccess.com