Glass Pressing Simulation Study of glass pressing simulation of high temp.

1
An efficient method for analysis and design of industrial products or process (Glass Pressing Simulation ) Glass Pressing Simulation Study of glass pressing simulation of high temp. Software for Pressing simulation (POLYFLOW, DEFORM) is very expansive Used ANSYS for Analysis pressing simulation Progress Glass Pressing Hotm olten glass C old rigid glass Mould Material property Density 2214kg/m^3 Specific Heat 1141J/Kg`c Thermal conductivity 2.34Wm^2K Viscosity In gragh Plunger Glass Mould Water cooling Aircooling Boundary Condition Viscosity flow on steady static & Thermal conduct on Time frequency Flow analysis : FLOTRAN element FLUID141 Thermal conduct analysis : THERMAL element PLANE55 Temp. 900 Temp. 950 Temp. 900 & Angle 30 Temp. 1000 Temp. 1000 & 0.5ATM Temp. 1000 & Angle30 Temp. 1000 & Angle60 Result 플플플플 플플 , 플플 플 플플 플 플플 플플플 플플 플플 플플 Unfill 플플 플플 플플 플플 플플플플 플플 CAD/CAE 효효효 효효 효효 효효 효효 효효 CAE 플플 플플 플 플 플플 플플 플플 플플 플플 플 플플 플플 플플플 CAD 플플 플플 CAD 플 API 플플플 플플플 플플플 2-D Model Progress Glass Pressing on Initial setup 100,120,140mm/s Unfilled ; 100mm/s 120mm/s 6.3sec 140mm/s 5.5sec 14.0 14.5 15.0 15.5 16.0 16.5 17.0 1.0 3.0 5.0 7.0 9.0 Tim e(sec) Thickness(m m ) P lunger speed 140m m /s P lunger speed 120m m /s P lunger speed 100m m /s Progress Glass Pressing on changed Initial velocity Progress Glass Pressing on changed Initial weight Increased weight 70,82,90kN unfilled ; 70kN 14.0 14.5 15.0 15.5 16.0 16.5 17.0 1.0 3.0 5.0 7.0 9.0 Tim e(sec) Thickness(mm ) P lunger load 90kN P lunger load 82kN P lunger load 70kN Progress Glass Pressing on changed Initial Temp. Temp. changed 900,950,995 unfilled ; 900,950 The critical Temp. 992 14 18 22 26 30 0.0 2.0 4.0 6.0 8.0 10.0 Tim e(sec) Thickness(m m ) Initialgob tem perature 995 Initialgob tem perature 950 Initialgob tem perature 900

description

Temp. 900. Temp. 950. Progress Glass Pressing on Initial setup. An efficient method for analysis and design of industrial products or process (Glass Pressing Simulation ). Glass Pressing Simulation Study of glass pressing simulation of high temp. - PowerPoint PPT Presentation

Transcript of Glass Pressing Simulation Study of glass pressing simulation of high temp.

Page 1: Glass Pressing Simulation  Study of glass pressing simulation of high temp.

An efficient method for analysis and design of industrial products or process

(Glass Pressing Simulation )

Glass Pressing Simulation Study of glass pressing simulation of high

temp. Software for Pressing simulation (POLYFLOW,

DEFORM) is very expansiveUsed ANSYS for Analysis pressing simulation

Progress Glass Pressing

Hot molten glass

Cold rigid glass

Mould

Material propertyDensity 2214kg/m^3Specific Heat 1141J/Kg`cThermal conductivity 2.34Wm^2KViscosity In gragh

Plunger

Glass

Mould

Watercooling

Air cooling

Boundary Condition

Viscosity flow on steady static

& Thermal conduct on Time frequency

Flow analysis

: FLOTRAN element FLUID141

Thermal conduct analysis

: THERMAL element PLANE55

Temp. 900 Temp. 950

Temp. 900 & Angle 30 Temp. 1000

Temp. 1000 & 0.5ATM Temp. 1000 & Angle30

Temp. 1000 & Angle60

Result

플런저의 속도 , 압력 및 초기 곱 온도 변화에 따른 결과 분석Unfill 불량 여부 조사최저 임계온도 조사

CAD/CAE 효과적 연계 의한 성형 공정 구현CAE 에서 유동 및 열 전달 문제 해석자유 표면 및 접촉 점의 갱신을 CAD 에서 구현CAD 의 API 함수를 이용한 자동화

2-D Model

Progress Glass Pressing on Initial setup

100,120,140mm/s

Unfilled ; 100mm/s

120mm/s 6.3sec

140mm/s 5.5sec

14.0

14.5

15.0

15.5

16.0

16.5

17.0

1.0 3.0 5.0 7.0 9.0Time(s ec)

Thic

knes

s(m

m)

Plunger speed 140mm/s

Plunger speed 120mm/s

Plunger speed 100mm/s

Progress Glass Pressing on changed Initial velocity

Progress Glass Pressing on changed Initial weight

Increased weight 70,82,90kN

unfilled ; 70kN

14.0

14.5

15.0

15.5

16.0

16.5

17.0

1.0 3.0 5.0 7.0 9.0

Time(sec)

Thic

knes

s(m

m)

Plunger load90kNPlunger load82kNPlunger load70kN

Progress Glass Pressing on changed Initial Temp.

Temp. changed 900,950,995

unfilled ; 900,950

The critical Temp. 992

14

18

22

26

30

0.0 2.0 4.0 6.0 8.0 10.0

Time(sec)

Thic

knes

s(m

m)

Initial gob temperature 995

Initial gob temperature 950

Initial gob temperature 900