Glass pin post insulator - Pagrindinis - Aiz EN).pdfISHOS - glass pin post insulator Insulators...

3
Glass pin post insulator AIZ, RUSSIA AIZ, BELARUS AIZ, KAZAKHSTAN AIZ, LITHUANIA www.bus-bar.ru www.aiz.by www.aiz.kz www.bus-bar.eu [email protected] [email protected] [email protected] [email protected] +7-495-7412286 +375-222455264 +7-717-296-5353 +370-62749925 AIZ- registrated trade mark of the group of companies AIZ

Transcript of Glass pin post insulator - Pagrindinis - Aiz EN).pdfISHOS - glass pin post insulator Insulators...

Glass pin post insulator

AIZ, RUSSIAAIZ, BELARUSAIZ, KAZAKHSTANAIZ, LITHUANIA

www.bus-bar.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@bus-bar.eu

+7-495-7412286+375-222455264+7-717-296-5353+370-62749925

AIZ- registrated trade mark of the group of companies AIZ

ISHOS - glass pin post insulator

Insulators ISHOS-10-20 are based on insulating parts and made of tempered glass. This design feature makes it easy to identify the damaged insulator. In case of breakdown of the insulator, insulating piece of tempered glass breaks into many small fragments. Thus ISHOS cannot be formed as a result of crack during electrical or mechanical abuse, through which will be a short circuit to ground, and it is impossible to detect such an insulator without electrical testing. In the event of breakdown or micro cracks insulation item located in the state of stress as a result of hardening breaks and points to the failed insulator. The pattern of destruction is identical to suspension insulators made of tempered glass.

Advantages of special insulators ISHOS-10-20 for disconnectors PLHD against porcelain insulators ONSH-10-20:

- Excludes the fall of the insulator and knife PLHD to the operator from a height of support; - high value-more than withstood the breaking load (more than 2 times) -more than the high value of resistance to dynamic shocks (more than 20 times) - Earthquake resistant, vandal-proof - No hidden defects in the insulating body.

The mechanical strength of the insulator ISHOS through design features is limited only by the strength of the metal pin of the bottom flange.

Useful service life- 30 years.

CONDITIONAL DESIGNATION

2- pollution degree

1- placement category GOST 15150

climate desing and category of spasingaccording GOST 15150, IEC60721, IEC60068

UHL1 -

Nominal voltage, kV

Highest working voltage, kV

Minimum lightning impulse withstandvoltage, kV

50%- discharge voltage ofindustrial frequency atpolluted and humid conditions, kV

For specified surface conductivityof polluted layer, mkCm

Minimum failing torsionmoment, kNxm

10

20

2

30

Minimum failing load atbending, kN

TYPE TESTS

Assemblage

External inspection ( outer view and marking )

Weight, length of insulating part,fitting dimensions, armature spacingcorrespondence

Quality and thickness of armature’santicorrosional coating

Alternating short term test voltagein dry condition

Evaluation of partial discharge level

Hydrophobic resistance to water

Hydrophobic resistance to coloring liquid

Adhesion of coating layer to insulating body

Failing load at bending (torsion )

Minimum creepage distance, cm

Testing load at bending ( torsion ) 1 min. withstand.Deviation angle control at bending ( torsion ) andabsence of plastic deformation at bending ( torsion )

ISHOS - glass pin post insulator

ISHOS-10-20-2 UXL1

TECHNICAL CHARACTERISTICS

GOST R 52082-03, TS3494-005-59116459-05

20- breaking load in kN,

Weight, not more than, kg

Bottom flange fitting dimensions, mm

Building height H, mm 210

4.2

120х4 hol. 13

10

12

75

13

nominal voltage, kV10-

292AIZ, RUSSIAAIZ, BELARUSAIZ, KAZAKHSTANAIZ, LITHUANIA

www.bus-bar.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@bus-bar.eu

+7-495-7412286+375-222455264+7-717-296-5353+370-62749925

AIZ- registrated trade mark of the group of companies AIZ

120х4 hol. 15Top flange fitting dimensions, mm

ISHOS - glass pin post insulator

Insulators ISHOS-20-10 are based on insulating parts and made of tempered glass. This design feature makes it easy to identify the damaged insulator. In case of breakdown of the insulator, insulating piece of tempered glass breaks into many small fragments. Thus ISHOS cannot be formed as a result of crack during electrical or mechanical abuse, through which will be a short circuit to ground, and it is impossible to detect such an insulator without electrical testing. In the event of breakdown or micro cracks insulation item located in the state of stress as a result of hardening breaks and points to the failed insulator. The pattern of destruction is identical to suspension insulators made of tempered glass.

Advantages of special insulators ISHOS-20-10 for disconnectors PLHD against porcelain insulators ONSH-20-10:

- Excludes the fall of the insulator and knife PLHD to the operator from a height of support; - high value-more than withstood the breaking load (more than 2 times) -more than the high value of resistance to dynamic shocks (more than 20 times) - Earthquake resistant, vandal-proof - No hidden defects in the insulating body.

The mechanical strength of the insulator ISHOS through design features is limited only by the strength of the metal pin of the bottom flange.

Useful service life- 30 years

ONSH-20-10

2- pollution degree

1- placement category GOST 15150

climate desing and category of spasingaccording GOST 15150, IEC60721, IEC60068

UHL1 -

Nominal voltage, kV

Highest working voltage, kV

Minimum lightning impulse withstandvoltage, kV

50%- discharge voltage ofindustrial frequency atpolluted and humid conditions, kV

For specified surface conductivityof polluted layer, mkCm

Minimum failing torsionmoment, kNxm

10

20

2

30

Minimum failing load atbending, kN

TYPE TESTS

Minimum creepage distance, cm

ISHOS - glass pin post insulator

TECHNICAL CHARACTERISTICS

10- breaking load in kN,

Weight, not more than, kg

Bottom flange fitting dimensions, mm

Building height H, mm 280

4.2

140х4 hol. 13

20

24

125

26

nominal voltage, kV20-

140х4 hol. 15Top flange fitting dimensions, mm

Assemblage

External inspection ( outer view and marking )

Weight, length of insulating part,fitting dimensions, armature spacingcorrespondence

Quality and thickness of armature’santicorrosional coating

Alternating short term test voltagein dry condition

Evaluation of partial discharge level

Hydrophobic resistance to water

Hydrophobic resistance to coloring liquid

Adhesion of coating layer to insulating body

Failing load at bending (torsion )

Testing load at bending ( torsion ) 1 min. withstand.Deviation angle control at bending ( torsion ) andabsence of plastic deformation at bending ( torsion )

GOST R 52082-03, TS3494-005-59116459-05

293

ISHOS-20-10-2UXL1

CONDITIONAL DESIGNATION

AIZ, RUSSIAAIZ, BELARUSAIZ, KAZAKHSTANAIZ, LITHUANIA

www.bus-bar.ruwww.aiz.bywww.aiz.kzwww.bus-bar.eu

[email protected]@[email protected]@bus-bar.eu

+7-495-7412286+375-222455264+7-717-296-5353+370-62749925

AIZ- registrated trade mark of the group of companies AIZ