SGG STADIP PROTECT BS:protection against explosions
SGG STADIP PROTECT BS (Blast Security)glass has been tested in accordance withthe 4 categories of standard BS EN 13541.SGG STADIP PROTECT BS laminated safetyglass is available in a splinter version(S, fragments of glass scattered by theexplosion) or no splinter/no spallversion (NS, no dangerous fragmentsof glass scattered by the explosion).
SGG STADIP SILENCE:Protection against noise
SGG STADIP SILENCE acoustic laminatedsafety glass offers enhanced acousticinsulation. Its mechanical propertiesare identical to the rest of the SGG STADIPand SGG STADIP PROTECT range, providingthe same level of protection as standardlaminated safety and security glasses.
SGG LITE-FLOOR: glass floor panels
The high mechanical strength ofSGG STADIP glass means that it can be usedin structural applications, such as floors.Incorporated into the SGG LITE-FLOORsystem, it is specifically designed to bearthe loads required for the application,see page 213.
P r o c e s s e dP r o d u c tV a r i a t i o n s
Glass in the SGG STADIP and SGG STADIPPROTECT ranges can be*:
- Edgeworked after assembly, providingit does not comprise any toughenedor heat-strengthened components
- Sandblasted or acid etched
- Heat-strengthened (SGG PLANIDUR),toughened (SGG SECURIT) or heat soaktested (SGG SECURIPOINT). The componentsmust be heat-treated before laminating
- Drilled and notched: The individualcomponents are best processed priorto laminating where practical.
- Coated with a solar control coating(SGG STADIP ANTELIO, SGG STADIPCOOL-LITE), or a low-emissivity coating(SGG STADIP PLANITHERM)
- Assembled into double-glazing(SGG CLIMALIT SAFE, SGG CLIMAPLUS SAFE,SGG CLIMALIT PROTECT, SGG CLIMAPLUSPROTECT, SGG CLIMALIT SILENCE,SGG CLIMAPLUS SILENCE).
* Certain treatments may alter the mechanical properties of the product and modify its classification.
SGG STADIP SILENCE glass is processed inthe same way as the rest of the SGG STADIPand SGG STADIP PROTECT ranges.
SGG STADIP 24
SGG STADIP 208
SAINT-GOBAIN GLASS PROTECT
SGG STADIP PROTECT HC (High Calibre)glass provides protection against firefrom shotguns (classes SG1 and SG2).
Composition: a number of glasscomponents, often of differentthicknesses, assembled usingseveral 0.38 mm or 0.76 mm thickPVB interlayers.
Name : SGG STADIP PROTECT HS XYY (N)SWhere: - X defines the class of the
corresponding Europeanstandard (BS EN 1063) (forexample: 1 for BR1)
- YY defines the total thicknessof the glass in mm
- NS or S stands for no-splintersor splinters, indicatingwhether an anti-spall layerhas been added.
SGG STADIP
207 SGG STADIP
Safety and Security24
SGG STADIP PROTECT HS SGG STADIP PROTECT BS
Protection against explosions
Class SGG STADIP Thickness WeightBS EN 13541 PROTECT (mm) (Kg/m2)
ER1 S BS 110-S 10 22
ER1 NS BS 118-NS 18 40
ER2 S BS 218-S 18 39
ER2 NS BS 226-NS 26 63
ER3 S BS 331-S 31 73
ER4 S BS 427-S 27 68
ER4 NS BS 433-NS 33 83
STADIP PROTECT FS (Full Security)glass also has, in addition to itsbullet-resistant classification, (standardBS EN 1063), an anti-vandalism andanti-burglary classification (standardBS EN 356). This glass is suitable formultifunctional applications, combiningprotection against firearms,anti-vandalism and burglary.
Composition: a number of glasscomponents, often of differentthicknesses assembled with several0.38 mm or 0.76 mm thickPVB interlayers.
Name : SGG STADIP PROTECT FS RST.YY (N)SWhere: - R defines the burglary
protection class of the glasswith BS EN 356
- S defines the BR bulletresistance class of the glass inaccordance with BS EN 1063
- T defines the SG bulletresistance class of the glass inaccordance with BS EN 1063
- YY defines the total thicknessof the glass in mm
- NS or S indicates theabsence or presence, of ananti-spall layer.
SGG STADIP PROTECT FS
Protection against firearm attack andProtection against vandalism and burglary
Class SGG STADIP Thickness WeightBS EN 356 & 1063 PROTECT (mm) (kg/m2)
P6B+BR5-S+SG1-S FS 651.34-S 34 81
P7B+BR5-S+SG1-S FS 751.36-S 36 86
P8B+BR6-S+SG2-S FS 862.41-S 41 92
SGG STADIP PROTECT HC
Protection against fire from shotguns
Class SGG STADIP Thickness WeightBS EN 1063 PROTECT (mm) (kg/m2)
SG1 S HC 133-S 33 75
SG1 NS HC 171-NS 71 171
SG2 S HC 247-S 47 114
SG2 NS CP-HC 284-NS 84 177
Protection against fire arm attack
Class SGG STADIP Thickness WeightBS EN 1063 PROTECT (mm) (kg/m2)
BR1 NS HS 113-S 13 31
BR1 NS HS 120-NS 20 48
BR2 S HS 219-S 19 44
BR2 NS HS 234-NS 34 83
BR3 S HS 323-S 23 53
BR3 NS HS 349-NS 49 119
BR4 S HS 431-S 31 73
BR4 NS HS 454-NS 54 130
BR5 S HS 536-S 36 82
BR5 NS HS 558-NS 58 140
BR6 S HS 647-S 47 112
BR6 NS CP-HS 673-NS 73 149
BR7 S CP-HS 783-S 83 176
BR7 NS HS 787-NS 87 205