GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30...

36
The best choice for the best profit! LSIS CO., Ltd. always do our best to give the maximum profit to those who selects out product. 2012. 10. 20 GIPAM-10 Manager Cautions for safety Please read the cautions for safety before using and use it precisely. After reading, keep the instruction manual where the user can always see. GIPAM-10 series tool for relay

Transcript of GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30...

Page 1: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

The best choice for the best profit!

LSIS CO., Ltd. always do our best to give the maximum profit to those who selects out

product.

2012. 10. 20

GIPAM-10 Manager

Cautions for safety

● Please read the cautions for safety before using anduse it precisely.

● After reading, keep the instruction manual where theuser can always see.

GIPAM-10 series tool for relay

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 1

Page 2: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

Contents

Contents

Chapter1 GIPAM-10 MANAGER .............................................................................................1-1

1.1 Features and main function.......................................................................................................................1-1

1.1.1 Features...............................................................................................................................................1-1

1.1.2 Main function........................................................................................................................................1-1

1.2 System requirements specification...........................................................................................................1-1

1.3 Installation.................................................................................................................................................1-3

1.3.1 Installation............................................................................................................................................1-3

1.3.2 Action of program.................................................................................................................................1-3

1.4 Notice........................................................................................................................................................1-4

1.4.1 General…………..................................................................................................................................1-4

1.4.2 USB connection...................................................................................................................................1-4

Chapter 2 Usage of program....................................................................................................2-1

2.1 Screen construction..................................................................................................................................2-1

2.2 Menu construction.....................................................................................................................................2-2

2.3 Add/delete of device.................................................................................................................................2-4

2.4 Communication connection......................................................................................................................2-5

2.5 Files saving and opening..........................................................................................................................2-6

2.6 Report.......................................................................................................................................................2-6

2.7 Comtrade Analysis ...................................................................................................................................2-7

2.8 Setting option............................................................................................................................................2-7

2.9 Language ..................................................................................................................................................2-7

Chapter 3 Setting and monitoring..........................................................................................3-1

3.1 GIPAM-10 Setting ....................................................................................................................................3-2

3.1.1 Protective relay setting..........................................................................................................................3-2

3.1.2 Device setting.......................................................................................................................................3-5

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 1

Page 3: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

Contents

3.2 Record reading..........................................................................................................................................3-8

3.2.1 Event record.........................................................................................................................................3-8

3.2.2 Fault record........................................................................................................................................3-10

3.2.3 Event/fault record……….....................................................................................................................3-12

3.2.4 Waveform analysis..............................................................................................................................3-14

3.3 Information/status....................................................................................................................................3-20

3.3.1 Device information...............................................................................................................................3-20

3.3.2 DI/DO status........................................................................................................................................3-21

3.3.3 Relaying value......................................................................................................................................3-21

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 2

Page 4: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

1-1

Chapter1 GIPAM-10 Manager

Chapter1 GIPAM-10 Manager

1.1 Features and main function

GIPAM-10 Manager is a PC managing program used for GIPAM-10 and can simply set and confirm the functions

and relaying elements. Set each parameter in the PC and download by using USB communication port and the

setting will be finished. All settings can be download/upload so it is easy for maintenance.

GIPAM-10 Manager is easy to use, and provides comfort on setting and managing the GIPAM-10 relay.

1.1.1 Features

GIPAM-10 Manager (is)

● easy to use by constructing user-friendly interface.

● applied the latest Look & Feel.

● supported in many languages. Program can be run in English or Korean.

● able to analyze the waveform to analyze the fault.

● supports USB communication so it is easy to communicate with the device.

1.1.2 Main function

● Device setting

It can download all the setting of each relaying elements on the device by setting protective relay. It

can set the voltage transformer, current transformer, digital compression.

● Record opening

It is able to inquire/analyze the event and fault record, and can also save the files. You can comparison

analyze the contact value of module(CT, PT), DI/DO on the fault waveform screen.

● Device information/condition

It can inquire the model firmware version of related device, rating of device and monitor the I/O of DI/DO

and measurements on the device information/condition screen.

1.2 System requirements specification

The least condition to run the program is as follows.

● IBM-PC Compatible computer above Intel Pentium 4

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 1

Page 5: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

1-2

Chapter1 GIPAM-10 Manager

● Memory above 1G Byte

● VGA graphic card and monitor above native resolution 1024 X 768

● MS Windows 2000/XP/2003 /Vista and Windows 7

● Hard disk with free of 50G above

● USB port above 1.0

Refer

You need to install the system which is higher than Adobe Acrobat Reader 5.0 in order to read

the user’s instruction manual.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 2

Page 6: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

1-3

Chapter1 GIPAM-10 Manager

1.3 Installation

You may install GIPAM-10 Manager with installation program, and can download on the website of LSIS

CO., Ltd.

1.3.1 Installation

In order to install the GIPAM-10 Manager, install the provided installation program and follow the instruc-

tions that are given in the program.

1.3.2 Program execution

There will be short-cut icon and program group of GIPAM-10 Manager on the screen as seen below after

installing the program. You may execute the GIPAM-10 Manager with these.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 3

Page 7: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

1-4

Chapter1 GIPAM-10 Manager

1.4 Notice

1.4.1 General

● Execute the program in approved OS or installation condition.

There may be error or malfunction on the whole or a part of the program if using/installing it in unau-

thorized OS

1.4.2 USB connection

● The window driver of GIPAM-10 Manager should be installed in the system in order to communicate

with the device

● The USB driver of GIPAM-10 is ‘CDC_Driver.inf’ which is inside the ‘usbdrv’ folder of program instal-

lation directory.

When first connecting with the device, install the window driver by selecting the above driver file.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 4

Page 8: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-1

Chapter2 Program Usage

Chapter 2 Program Usage

2.1 Screen construction

GIPAM-10 Manager program can inquire the setting, measurement, monitoring and event record, fault record of

GIPAM-10 and consisted as to maximize the comfort on performing the function.

GIPAM-10 Manager is PC managing program which is based on WINDOW and follows the basic construction of

window program so anyone who can run PC, is able to use.

1. Title bar: Indicates the name of program and device, route of saving file.

2. Menu bar: It includes functions to run the program.

3. Tool bar: It is constructed of frequently using functions.

The main construction elements of the screen are as follows.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 1

Page 9: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-2

Chapter2 Program Usage

4. Device tree: This article is to set and monitor the device and the device list which is added to the pro-

gram.

Click the name of the device with right button of the mouse, then you’ll see the popup menu which

you can set the device.

5. Main screen: Indicates each screen in tap window.

6. Condition bar: Indicates the LSIS CO., Ltd. logo and other information.

2.2 Menu composition

The menu and tool bar of GIPAM-10 Manager are consisted as follows.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 2

Page 10: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-3

Chapter2 Program Usage

(1) [File] menu

(2) [Viewing] menu

(3) [Device] menu

(4) [Window] menu

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 3

Page 11: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-4

Chapter2 Program Usage

(5) [Tool] menu

(6) [Language] menu

(7) [Tool] menu

2.3 Add/delete of device

This is to add/delete the device on GIPAM-10 Manager.

(1) Add device

- Select [add device] on the tool bar or [file->add device] on the menu, then enter the name of device and

select the model type, then press confirm.

As for CT Type and GT Type, the rating shall be additionally entered.

- When adding the device on the [File ➔ Add from GIPAM-10], it can automatically apply the model type

with communication setting.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 4

Page 12: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-5

Chapter2 Program Usage

(2) Delete device

Select the [delete device] on the tool bar or [file->delete device] on the menu.

2.4 Communication linkage

This function links the communication with the device.

(1) Linkage setting

At the combo box to select communication port, select the port which is connected to the computer

with USB. Then press ‘connect’ button and it will be connected to GIPAM-10, and if you press ‘confirm’

button, it only saves the setting content.

(2) Connecting

It tries to connect to the device by communicating. If succeed to connect, the window will be closed

and if fails, there will be a failure message.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5

Page 13: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-6

Chapter2 Program Usage

2.5 File saving and opening

This function is to save the setting in file and to open the saved file.

The name of the saved file, opening file will be displayed on the title bar of the program.

(1) File saving

It saves the setting of the device into file.

(2) File opening

When opening the file which is saving the setting of the device, it is added as the new device.

2.6 Report

You may use the report function in the ‘device’ ➔ ‘report’ of the menu, or on the popup menu of the device ex-

plorer.

You can print out the device information, device setting, setting of relaying element with the report function or save

it into Excel file.

➔ Look ahead : To preview the screen which will be printed.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 6

Page 14: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

2-7

Chapter2 Program Usage

➔ Print : Print the report.

➔ Save : Save the report into Excel file or Html file.

Cautions

Report function is to print the data that are currently inside the GIPAM-10 Manager.

It may be different from the actual setting of the device. When to print the setting that is equal to

the actual content of the device, you need to upload all the data of the device to the PC before

creating the report.

2.7 Comtrade Analysis

‘ComtradeAnalysis2.exe’ can analyze the files that are saved in CONTRADE file and can additionally execute the

external program.

COMTRADE file is IEC60255-24 standard file. By using this function, you can analyze the files that are saved in

GIPAM-10 Manager in detail.

2.8 Option setting

This is to register the ComtradeAnalysis program.

Registered program is used to execute external program with the ‘ComtraceAnalysis execution’ in the ‘Tool’

menu.

2.9 Language

Transfers the UI(User Interface) language of GIPAM-10 Manager.

There are Korean and English.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 7

Page 15: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-1

Chapter3 Setting and monitoring

Chapter 3 Setting and monitoring

When adding the device on the GIPAM-10 Manager, there will be a tree as below to set and monitor the device.

If you double click an item on the tree, related screen will show up.

The highest item of the tree on the screen displays the name of device and the model type.

The icon of the device is shown as , when it is not connected to the device, and when it is connected, it is

shows as .

Also, you can grasp the detail as table below by using the menu and the tool bar.

When device is not connected When device is connected

The tool bar and connec-

tion menu, connection set-

ting to connect with the

device are in activated

condition

The tool bar and menu to

transfer the remote local

condition, confirm and

changing password, dis-

connection of the device

are in activated condition.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 1

Page 16: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-2

Chapter3 Setting and monitoring

3.1 GIPAM-10 Setting

You can set the GIPAM-10.

There are detail items of each protective relay, system setting, device setting on the bottom tree.

3.1.1 Protective relay setting

Shown below is the protective relay setting screen.

You can selectively set the protective relaying element in the protective relay setting, and can download/up-

load the set changes to the applicable relay.

(1) Upload/download of relaying element setting

Press to download the setting of the relaying element and press to

upload it.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 2

Page 17: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-3

Chapter3 Setting and monitoring

(2) Characteristic curve

For the relaying element with timing characteristic, it shows the tripping time in graph.

To know the time value of particular X axis, drag the marker (the red line on the graph) then the X

value and trip time will show on the right of the graph. With the standard of X axis value as 1, returning

characteristic is on the left and operation characteristic is on the right. Press ‘close’ button to exit

from the screen.

Characteristic curve is indicated according to characteristics of each relaying element

(3) Calculating function

In current type model, you can calculate the operation value of 46 NSOCR element beforehand.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 3

Page 18: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-4

Chapter3 Setting and monitoring

(4) Setting screen of relaying element.

The setting screen of relaying element is consisted of a screen where you can enter each setting

value and you can select the minimum, maximum unit or setting value list on the combo according

to the characteristic of each value.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 4

Page 19: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-5

Chapter3 Setting and monitoring

3.1.2 Device setting

Performs the setting of the device and,

when downloading the setting, press , and press , to upload.

When uploading or downloading the setting, check the ‘selected item only’ to communicate only the se-

lected (clicked) item.

(1) System setting

You can set the CT/PT etc 1st,2ndproportionofGIPAM-10 in system setting.

The setting screen is divided into current type, voltage type, ground type according to the model.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5

Page 20: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-6

Chapter3 Setting and monitoring

(2) Setting Group setting

The setting of Setting Group is to set the group which is actually operating (Active) among the 3

groups of CT (current type) model.

Setting Group is only in CT (current type) model.

< CT type >

< PT type>

< GT type>

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 6

Page 21: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-7

Chapter3 Setting and monitoring

(3) Communication setting

This is to set the communication specification for distant system composition.

(4) IO setting

Provides DI and DO setting.

(5) CBF setting

Setting circuit breaker Fail.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 7

Page 22: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-8

Chapter3 Setting and monitoring

3.2.1 Event record

You may inquire the event record which is saved in the device, and the contents that are saved in the

file. The maximum number that can be saved in the device is 32.

3.2 Record reading

Can inquire and analyze the event, fault waveform and fault record of GIPAM-10.

(1) Upload (reading at the device)

Click ‘upload’ button to upload the event record from the device to the PC and to inquire, analyze

the event information.

(2) Delete

Click ‘delete’ button to delete all the event records that are saved in the device.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 8

Page 23: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-9

Chapter3 Setting and monitoring

(3) Opening

This indicates in the list by reading the file which saves the event information.

Press ‘open’ button, and a file opening box as seen in the picture will be displayed.

File extension has following meaning.

Extension Explanation

*.evt It is an event record file which is saved as a text file in GIPAM-10 Manager.

(4) Saving

This saves the listed event on the screen into file. The saved file can be confirmed as seen above

(3) by loading it.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 9

Page 24: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-10

Chapter3 Setting and monitoring

3.2.2 Fault record

You may inquire the fault record which is saved in the device, and the contents that are saved in the

file. The maximum number that can be saved in the device is 32.

(1) Upload (reading at the device)

Press ‘upload’ button, and the fault record will be uploaded to PC from the device and can inquire,

analyze the fault information.

(2) Delete

Press ‘delete’ button to delete all the fault record that are saved in the device.

(3) Opening

It indicates the fault information on the list by reading the fault record which is saved in file.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 10

Page 25: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-11

Chapter3 Setting and monitoring

(4) Saving

This saves the listed event on the screen into file. The saved file can be confirmed as seen above

(3) by loading it.

Press ‘open’ button, and a file opening box as seen in the picture will be displayed.

File extension has following meaning.

Extension Explanation

*.flt It is an event record file which is saved as a text file in GIPAM-10 Manager.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 11

Page 26: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-12

Chapter3 Setting and monitoring

3.2.3 Event / Fault record

You may inquire the fault record and event record which is saved in the device, and the contents that

are saved in the file. It shows 32 fault records and 32 event records -which is the maximum number

that can be saved in the device- in chronological order.

(1) Upload (reading at the device)

Click ‘upload’ button, and the event/fault record will be uploaded to the PC from the device and

will show in reverse-chronological order.

(2) Delete event

Click ‘delete event’ button and all the event records that are saved in the device will be deleted.

Cautions

The sort order is not the actual order of save, it is arranged by the Time Stamp which is recorded

in the fault/event record. Due to changing the time of device, it may be different from the actual

time when event and fault occurred.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 12

Page 27: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-13

Chapter3 Setting and monitoring

(3) Delete fault

Click ‘delete fault’ button and all the fault records that are saved in the device will be deleted.

(4) Opening

It indicates the fault information on the list by reading the fault record which is saved as file.

Press ‘open’ button, and a file opening box as seen in the picture will be displayed.

File extension has following meaning.

Extension Explanation

*.eft It is fault/event record file which is saved as a text file in GIPAM-10 Manager.

(5) Saving

This saves the listed event on the screen into file. The saved file can be confirmed as seen above

(4) by loading it.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 13

Page 28: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-14

Chapter3 Setting and monitoring

3.2.4 Waveform analyzing

It can read the waveform, saved in the device, and analyze it.

Indicated waveform also can be saved in file.

(1) Waveform list

The maximum number of fault record that can be saved in GIPAM-10 is 4. If you click ‘waveform

list’ button, the waveform list, saved in the device, will be uploaded and arranged in chronological

order on the combo box and the user may select it.

(2) Upload

Click ‘upload’ button and you can upload and analyze the waveform from the device which you

selected the time on the left side of the combo box.

Refer

When uploading the waveform, the time of waveform which you selected on the combo box and

the time when actually waveform was uploaded may be different and also there may be no data

of the selected waveform. The reason is that the waveform list and the actual list of the device

do not match, so you need to click the waveform list button again and renew the waveform list

before using.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 14

Page 29: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-15

Chapter3 Setting and monitoring

(3) COMTRADE

You can save the waveform into COMTRADE type and can analyze by using the ComtradeAnaly-

sis2 program.

[Save] : Saves the waveform by using COMTRADE standard.

Refer

COMTRADE is a standard format for excessive data in the power system. The standard is defined

in IEC 60255-24, and there is no amplification about COMTRADE on this manual so refer to

standard document for details.

There are 4 types of files in COMTRADE file.

‘*.cfg’ : It is setting and constructing file of ASCII text file. (essential)

‘*.dat’ : Data file which saves the value of record sample. (essential)

‘*.hdf’ : Saves the additional information which the user types in text. (selective)

‘*.inf’ : Can save the specific additional information which is selected by the manufac-

turer. (selective)

These are the files, and on this program, ‘*.cfg’, ‘*.hdr’, ‘*.dat’ files are supported.

When there is a screen to save the COMTRADE file, enter the application.

Item Explanation Notes

Station location Enter the device name.

The entered name of the device will be recorded

on the ‘*.cfg’ file.

Selective.

(number or English, 64 letters)

ID number or

the name of de-

vice

Enter the own ID. The entered name of the device

will be recorded on the ‘*.cfg’ file.

Selective.

(number or English, 64 letters)

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 15

Page 30: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-16

Chapter3 Setting and monitoring

(4) Waveform information

It includes the time when waveform was saved, number of cycle, pre cycle, and the sampling number

of saved waveform.

(5) Waveform view

You can enlarge and reduce the waveform or analyze by moving the X axis in the waveform graph.

X axis indicates the total number of Sample(the number of Cycle X Sample number per Cycle), and

Y axis is consisted of 3 areas, which indicates the DSP(PT, CT) value of module and an area indicating

DI/DO value, and AI/AO data.

To view and hide of each data (channel) can be selected with the checkbox in the exemplum.

If you click ‘confirm’ button after inputting the application, it will be saved in the same folder(directory),

‘*.cfg’, same as you named the file.

Select the ‘After saving, open with ComtradeAnalysis2’ check box and you’ll be able to analyze by

loading the Comtrade file which is saved in the analyzing program after saving the Comtrade file.

[Analyze] : You may analyze the waveform by using ContradeAnalysis2 program

At this time, temporarily save the Comtrade file, and automatically connect the saved file to be loaded

by ContradeAnalysis2.exe program.

Header file

information

It is the information recorded on the ‘*.hdr’ file,

and you can add explanation on memo about the

user or waveform

Selective.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 16

Page 31: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-17

Chapter3 Setting and monitoring

- Moving the X axis and enlargement/reduction

When to enlarge X axis,

First, click the enlarge button of the tool bar, and to reduce, click reduce button. Second, click

partial enlarging button, and drag the area on the chart area then the selected area will be en-

larged.

Y axis doesn’t change when enlargement/reduction.

You may move X axis by dragging the X axis with the mouse or use scroll bar.

- DSP(PT, CT of module) enlargement/reduction

DSP data indicates PT(voltage), CT(current) value on the same area(axis). So, when there is big

difference between voltage and current value, it may be hard to get the data when the value is

small as following picture.

At this time, click the area which indicates the DPS data with the mouse(the area will be indicated

with dotted line) and then can move, enlarge, reduce the Y axis of DSP area.

➔ Moving the axis

Move the axis by dragging with the mouse or use mouse wheel when the area is focused.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 17

Page 32: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-18

Chapter3 Setting and monitoring

➔ Enlargement of axis

While pressing the left button of the mouse on the area of axis, click ‘Ctrl’ key and drag the

mouse to upper side.

When the area of axis is focused, keep pressing ‘Ctrl’ key and rotate the mouse wheel to upper

side.

➔ Reduction of axis

While pressing the left button of the mouse on the area of axis, click ‘Ctrl’ key and drag the

mouse down.

When the area of axis is focused, keep pressing ‘Ctrl’ key and rotate the mouse wheel down.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 18

Page 33: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-19

Chapter3 Setting and monitoring

(6) Exemplum

Indicate the item name(channel) of each data and the location

value where marker is, on the exemplum area.

If you click the check box of the exemplum area, you may set it

to hide or to view the each item (channel) of the chart area.

You may change the color of data item (channel) by clicking the

color part on the left side of the check box.

(7) Marker location

The red line on the graph area indicates the location of the data, based on the current X axis, and

the value of each item on the exemplum.

Also, as picture below, it indicates the Cycle of the mark location and Sample of Cycle.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 19

Page 34: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-20

Chapter3 Setting and monitoring

3.3 Information/condition

In the information/condition screen, you may monitor the device information and rating of GIPAM-10, DI/DO con-

dition and measurement value.

3.3.1 Device information

In the device information screen, it shows the model/version/time and relay rating.

In model/version/time, it shows

- Device model

- Device version

- Date/time

and can set the time of GIPAM-10 relay by setting the date/time.

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 20

Page 35: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-21

Chapter3 Setting and monitoring

In relay rating, it shows

- Current

- Voltage

- Frequency

3.3.2 DI/DO condition

It indicates ON or OFF condition of each contact.

3.3.3 Measurement value

In the monitoring screen of measurement value, it shows the necessary measurement value of each

model.

CT type PT type GT type

la

lb

Vab

Vbc

IN

Io

GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 21

Page 36: GIPAM-10 series tool for relay GIPAM-10 Manager · GIPAM-10 Manager_레이아웃 1 13. 04. 30 오전 10:32 페이지 5. 2- 6 C a˝˜ ˛2 P˛˙ ˛aˇ U˚a 2.5 File saving and opening

3-22

Chapter3 Setting and monitoring

lc

lN

I2

IN max

Vca

Va

Vb

Vc

Vo

Vo max

Vub

Vo

IN max

Io max

Vo max

Vo-IN Ph.Angle

Vo-Io Ph.Angle

The end.