Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg]...
Transcript of Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg]...
![Page 1: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/1.jpg)
www.MirrorcleTech.com© 2019 Mirrorcle Technologies, Inc. All rights reserved.
Gimbal-Less Two-Axis Scanning MEMS Micromirrors
Device Datasheet S41369
![Page 2: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/2.jpg)
1
Device Parameters Summary
Device ID : S41369
Actuator Name: A5M24.2
Actuator Mode : Gimbal-less Dual-Axis Quasistatic
Mirror Type: Integrated
Mirror Size : 2.4mm diameter
Mirror Coating : Aluminum
Maximum Mech. Angle - X Axis [degrees] : 5.4198
Maximum Mech. Angle - Y Axis [degrees] : 5.3689
Maximum Vdifference - X Axis [V] : 158.4800
Maximum Vdifference - Y Axis [V] : 157.4400
Driver Bias Voltage (Vbias) [V] : 80
Maximum Mech. Angle - Coupled Axes [degrees] : 7.7471
Resonant Frequency - X Axis [Hz] : 901
Resonant Frequency - Y Axis [Hz] : 905
Quality Factor - X Axis : 82.6000
Quality Factor - Y Axis : 77.2000
Recommended LPF Cutoff Frequency (6th Order Bessel) [Hz] : 300
Date and Time Report was Created: 30-May-2018 at 19:27:51
![Page 3: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/3.jpg)
2
Static ResponseVoltage vs. Mech. Angle - Individual Axes
Voltage vs. Mech. Angle - Coupled Axes
![Page 4: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/4.jpg)
3
Frequency ResponseSmall Signal Frequency Response - Magnitude
Small Signal Frequency Response - Phase
![Page 5: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/5.jpg)
4
Step ResponseX-Axis Step Response
Y-Axis Step Response
![Page 6: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/6.jpg)
5
2D Lookup Tables
Voltage vs. X Mech. Angle - Lookup Table
Voltage vs. Y Mech. Angle - Lookup Table
![Page 7: Gimbal-Less Two-Axis Scanning MEMS Micromirrors Device … · 2019. 8. 19. · Mech. X Tilt [deg] 100 -100 nce, Vbias -150 -100 -50 o 50 100 ISO 00 00 oce, Time [s] NO Filter 300](https://reader036.fdocuments.us/reader036/viewer/2022071508/6129402c12e6be61983f75ad/html5/thumbnails/7.jpg)
2D Lookup Tables
6
Y vs. X Tilt - Addressable Mech. Angles