GERMICIDAL UVc LAMP AIR PURIFYING UNITS
Transcript of GERMICIDAL UVc LAMP AIR PURIFYING UNITS
UPA
· PERFECT FOR INDUSTRY ANDHIGH OCCUPATION PREMISES
· OPTIMAL FOR DATA CENTRES
. SUITABLE FOR PHARMACEUTICAL AND HEALTHCARE INDUSTRIES
AIR PURIFYING UNITS
ACCORDINGErP
MULTIPLE STAGES OF
FILTRATION
GERMICIDAL UVc LAMP
ACTIVATED CARBON
70% EFFICIENCY
99.95% EFFICIENCY
LAMP UVC GERMICIDE
· PURIFIES INDOOR AIR
· IMPROVES HEALTH
· CLEANS PARTICLESAND ODOURS
2
Units specifically designed for cleaning and purification of indoor air, in any type of premises and especially in areas with high occupancy, also suitable for pharmaceutical and healthcare applications.
UPA
Order code
Features:• Plug-fantypefanswithECtechnology.• Efficient,adjustableandlownoiselevel
equipment.• Filtrationstagesaccordingtomodel -FirststageofG4Filtering. -Activatedcarbonfilter. -FinalfilterF9efficiency70%. -HEPAH13finalfilter,99.95%efficiency. -HEPAH14finalfilter,99.99%efficiency. -UVcgermicidalchamber,dependingon ordercode.• Controlpanelwithon/offanddirtyfilters
indicator.• Twospeedselector.• Germicidalchamberoperationledindicator.• Fullyremovableforcleaningand
maintenance.• Insulatedpanels.
Motor:• E.C.motorsHighefficiencyexternal
rotortechnologyincorporatesconstantflowregulation,withtwo,pre-adjustablesetpoints.
• Singlephase200-230V–50/60Hz.
Finish:• Framesmadeformaluminumsection
and25mminsulatedpanels,pre-lacqueredexterior,galvanizedinterior.
Ondemand:• DriveModule1frontgrille.• Drivemodulewithcircularducts.• Equippedwithwheels.
Model Maximum flow Available pressure
Powersupply
Sound level Fan
(m3/h) (CFM) (Pa) (V) dB(A) (KW)
UPA-UV-1500 1,500 883 300 200-230V50/60Hz1Ph 47 0.76UPA-UV-3000 3,000 1766 300 200-230V50/60Hz1Ph 51 1.35UPA-UV-4500 4,500 2649 300 200-230V50/60Hz1Ph 55 2.7UPA-UH-1500 1,500 883 300 200-230V50/60Hz1Ph 47 0.76UPA-UH-3000 3,000 1766 300 200-230V50/60Hz1Ph 52 1.52
*AvailablepressurewithG4andF9filter*EffectivepowerofUVcradiation
Air purifying units
UPA — UV — 1500 — F-9 — CG
UV:VerticalUnitUH:HorizontalUnit
Airpurifyingunits
Airflowm3/h
F9filterH13HEPAfilterH14HEPAfilter
Vertical Unit (UV)
VerticalUnit(UV)idealfordirectuseintheroomsbeingpurified,itcanalsobesuppliedonrequestwithadrivemodulewithoutletdiffusiongrilleandwithwheelsifrequired.
Horizontal Unit (UH)
HorizontalUnit(UH)deignedtobeinstalledinceilingspacesandduct-edtotheareaswheretheairneedstobetreated.
Technical characteristics
Construction
GermicidalchamberUVc
3
F9orH13G4
Germicidalchamber
Activatedcarbonfilter
176 440 700
AN
AL
L
UPA-UV-1500 774 474 1600
UPA-UV-3000 774 779 1600
UPA-UV-4500 1079 779 1600
UPA-UH-1500 1450 774 479
UPA-UH-3000 1450 1366 479
Model L (mm)
AN(mm)
AL(mm)
Datasubjecttochangewithoutpriornotice
Theseairpurificationunitsareequippedwithfilterscapableofremov-ingatleast70%ofparticleslargerthan0.4μm.
ThestandardmodelcomeswithafirstG-4filterstageandafinalF-9filter,italsoincorporatesasstandard,anactivatedcarbonstage,de-
signedto removestaleodoursproducedduringeverydayuseof thepremises.
OptionaltypeH13orH14HEPAfilterscanbeinstalledwithaminimumretentioncapacityof99.95%forparticleslargerthan0.3μm.
Onrequest,thesepurificationunitscanbesuppliedwithanintegratedgermicidalchamberusingUV“C” lamps, inthespectrumof256nmwaveamplitudetodeactivateawidevarietyofmicroorganismsbyab-sorbingshortwavelengthenergythroughDNAandRNA.
CG-UV-1500 2 9,8
CG-UV-3000 4 19,6
CG-UV-4500 4 70
CG-UH-1500 2 9,8
CG-UH-3000 2 30
Model Germicidal chamber UVc(Number of lamps) (W)
W=EffectivepowerofUVcradiation
-Equippedwithwheels.-Drivemodulewithfrontgrille.-Drivemodulewithducts.
Dimensions mm
Filtering
Germicidal lamp
Accessories
Horizontal UnitVertical Unit
F9orH13
Activatedcarbonfilter
Germicidalchamber
G4
L
AL
AN
MS-UPA-1500 774 474 324 250 2
MS-UPA-3000 774 779 490 250 4
MS-UPA-4500 1079 779 490 250 6
Model L (mm)
AN(mm)
AL(mm)
D(mm)
Number of ducts
Drive modules
L
MS-UPA-FMS-UPA-CD AN
AL
www.sodeca.com
CHILESodeca Ventiladores, SpA.Sra. Sofía OrmazábalSanta Bernardita 12.005(Esquina con Puerta Sur)Bodegas 24 a 26, San Bernado, Santiago, CHILETel. +56 22 840 [email protected]
COLOMBIASodeca Latam, S.A.S.Sra. Luisa Stella PrietoCalle7 No. 13 A-44Manzana 4 Lote1, MontanaMosquera, CundinamarcaBogotá, COLOMBIATel. +57 1 756 [email protected]
PERUSodeca Perú, S.A.C.Sr. Jose Luis JiménezC/ Mariscal Jose Luis deOrbegoso 331. Urb. El pino. 15022 , San Luis. Lima, PERÚTel. +51 1 326 24 24Cel. +51 [email protected]
AMERICA RUSSIA
PORTUGALSodeca Portugal, Unip. Lda.PORTORua Veloso Salgado 1120/1138 4450-801 Leça de PalmeiraTel. +351 229 991 [email protected]
LISBOAPq. Emp. da Granja Pav. 29 2625-607 Vialonga Tel. +351 219 748 [email protected]
ALGARVERua da Alegria S/N8200-557 CortesõesTel. +351 289 092 [email protected]
UNITED KINGDOMSodeca Fans UK, Ltd.Mr. Mark NewcombeTamworth Enterprise CentrePhilip Dix House, Corporation Street, Tamworth , B79 7DN UNITED KINGDOMTel. +44 (0) 1827 216 [email protected]
FINLANDSodeca Finland, OyHUITTINENSales and WarehouseMr. Kai Yli-SipiläMetsälinnankatu 26FI-32700 Huittinen Tel. + 358 400 320 [email protected]
HELSINKI Smoke Control SolutionsMr. Antti KontkanenVilppulantie 9CFI-00700 HelsinkiTel. +358 400 237 [email protected]
HYVINKÄÄIndustrial ApplicationsMr. Jaakko TomperiNiinistönkatu 12FI-05800 HyvinkääTel. +358 451 651 [email protected]
ITALIAMarelli Ventilazione, S.R.L.Sr. Christian TosettiViale del Lavoro, 2837036 San Martino B.A. (VR), ITALYTel. +39 045 87 80 140Fax +39 045 99 22 [email protected]
EUROPE
HEADQUARTERSSodeca, S.L.U.
Pol. Ind. La BarriconaCarrer del Metall, 2E-17500 RipollGirona, SPAINTel. +34 93 852 91 11Fax +34 93 852 90 42General sales: [email protected] sales: [email protected]
PRODUCTION PLANTSodeca, S.L.U.
Ctra. de Berga, km 0,7E-08580 Sant Quirze de BesoraBarcelona, SPAINTel. +34 93 852 91 11Fax +34 93 852 90 42General sales: [email protected] sales: [email protected]
Ref.
04/2
020
RUSSIASodeca, L.L.C.Mr. Stanislav AlifanovSevernoye Shosse, 10 room 201 Business Park Plaza Ramstars 140105 Ramenskoye,Moscow region, RUSSIATel. +7 495 955 90 [email protected]