GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col....

14
revision: A - WIP drawing number: A0.01 project number:PENDING date: 29/05/2015 F O R A P P R O V A L GEORGE ST RESIDENCE COVER 78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50 DWG INDEX DWG # A0.01 A1.01 A2.01 A2.02 A2.03 A2.04 A2.05 A2.06 A2.07 A2.08 A3.01 A3.02 A3.03 A3.04 A3.05 A3.06 A3.07 A3.08 A3.09 A4.01 A4.02 A4.03 A4.04 A4.05 A4.06 A4.07 A4.08 A4.09 A4.10 A4.11 DRAWING NAME COVER SITE PLAN DEMOLITION GROUND FLOOR PLAN DEMOLITION FIRST FLOOR PLAN PROPOSED SLAB SETOUT PLAN PROPOSED GROUND FLOOR PLAN PROPOSED FIRST FLOOR PLAN PROPOSED ROOF PLAN PROPOSED GROUND FLOOR RCP PROPOSED FIRST FLOOR RCP NORTH ELEVATION SOUTH ELEVATION EAST ELEVATION WEST ELEVATION SECTIONS SECTIONS SECTIONS SECTIONS STAIR DETAILS INTERNAL ELEVATIONS - RUMPUS/GUEST INTERNAL ELEVATIONS - GARAGE INTERNAL ELEVATIONS - GARAGE INTERNAL ELEVATIONS - GROUND FLOO... INTERNAL ELEVATIONS - KITCHEN INTERNAL ELEVATIONS - PLAY ROOM INTERNAL ELEVATIONS - LIVING & BEDR... INTERNAL ELEVATIONS - BEDROOM 1 INTERNAL ELEVATIONS - BEDROOM 2 INTERNAL ELEVATIONS - BEDROOM 3 INTERNAL ELEVATIONS - 1ST FLOOR BA... REV A A A A A A A A A A A A A A A A A A A Proposed Perspective 0mm 4000 8000 20000 SCALE 1:400 @ A3 2 - Existing Perspective 0mm 4000 8000 20000 SCALE 1:400 @ A3 1 - GEORGE ST RESIDENCE 78 George Street, Mackay, QLD, 4740

Transcript of GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col....

Page 1: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A0.01project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCECOVER

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

DWG INDEX

DWG #A0.01

A1.01

A2.01

A2.02

A2.03

A2.04

A2.05

A2.06

A2.07

A2.08

A3.01

A3.02

A3.03

A3.04

A3.05

A3.06

A3.07

A3.08

A3.09

A4.01

A4.02

A4.03

A4.04

A4.05

A4.06

A4.07

A4.08

A4.09

A4.10

A4.11

DRAWING NAMECOVER

SITE PLAN

DEMOLITION GROUND FLOOR PLAN

DEMOLITION FIRST FLOOR PLAN

PROPOSED SLAB SETOUT PLAN

PROPOSED GROUND FLOOR PLAN

PROPOSED FIRST FLOOR PLAN

PROPOSED ROOF PLAN

PROPOSED GROUND FLOOR RCP

PROPOSED FIRST FLOOR RCP

NORTH ELEVATION

SOUTH ELEVATION

EAST ELEVATION

WEST ELEVATION

SECTIONS

SECTIONS

SECTIONS

SECTIONS

STAIR DETAILS

INTERNAL ELEVATIONS - RUMPUS/GUEST

INTERNAL ELEVATIONS - GARAGE

INTERNAL ELEVATIONS - GARAGE

INTERNAL ELEVATIONS - GROUND FLOO...

INTERNAL ELEVATIONS - KITCHEN

INTERNAL ELEVATIONS - PLAY ROOM

INTERNAL ELEVATIONS - LIVING & BEDR...

INTERNAL ELEVATIONS - BEDROOM 1

INTERNAL ELEVATIONS - BEDROOM 2

INTERNAL ELEVATIONS - BEDROOM 3

INTERNAL ELEVATIONS - 1ST FLOOR BA...

REVA

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

Proposed Perspective

0mm 4000 8000 20000

SCALE 1:400 @ A32-

Existing Perspective

0mm 4000 8000 20000

SCALE 1:400 @ A31-

GEORGE ST RESIDENCE78 George Street, Mackay, QLD, 4740

tracyh
Received (Auto Date)
Page 2: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A1.01project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCESITE PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

WG04

WG10WG

07WG09

WG08

WG06WG

05DG02

WG01

DG03

DG04

DG01

40.2

34m

,0°

0' 0

"

20.117m,90° 0' 0"

40.2

34m

,18

0° 0

' 0"

20.117m,270° 0' 0"

DG10

WG02

WG03

DG09

Lot 54RP702028

G E O R G E S T R E E T

55RP702028

53RP702028

1

RL 7.04

3

RL 7.04

2

RL 7.03

3

RL 7.02

0

RL 6.87

1

RL 6.88

6

RL 7.01

2

RL 7.01

6

RL 7.00

3

RL 6.88

9RL 6

.856

RL 7.01

3

RL 7.00

5

RL 7.03

0

RL 7.07

8

RL 7.13

1

RL 7.23

5

RL 7.21

2

RL 7.19

4

RL 7.22

1

RL 7.23

6

RL 7.24

1

RL 7.17

6

RL 7.13

1

RL 7.11

6

RL 7.06

4

RL 7.10

8

RL 7.18

7RL 7

.217

RL 7.31

5 7.210

RL 7.30

8

RL 7.30

8

RL 7.18

8

RL 7.07

9

RL 7.14

8

RL 7.12

5RL 7

.104

RL 7.13

6

RL 7.17

7RL 7

.191

RL 7.15

0

RL 7.12

5

RL 7.03

8

RL 7.59

4

RL 7.01

3

RL 7.03

1RL 7

.105

RL 7.17

8

RL 7.16

6

RL 7.13

1

RL 7.17

2

RL 7.16

5

RL 7.16

6

RL 7.13

3

RL 7.15

5

RL 7.15

7RL 7.13

2RL 7.44

1

RL 7.03

9

RL 7.03

7

RL 7.03

7

RL 7.03

0

RL 7.02

0

RL 7.72

4

RL 7.72

4

RL 8.73

8

RL 7.02

7

RL 7.02

2

RL 7.06

9

RL 7.11

7

RL 7.11

1

RL 7.04

1

RL 7.11

6

RL 7.08

3

RL 7.16

0RL 7.17

7

RL 7.17

4

RL 7.18

9

RL 7.22

7

RL 7.23

1

RL 7.01

1

RL 7.09

8

RL 7.05

6

RL 6.85

3

RL 6.85

4RL 7

.001

WM

ELEC

New exposed aggregatedriveway

EXISTINGPOOL & DECK

TURFED AREA

Existing tree to remain

New gate

Approximatelocation ofexisting sewer

Exist

ing co

ncre

te pa

th

Existing treeto remain

Existing treeto remain

Additional 10.9m²enclosed floor areaon First Floorshown dashed

RL 7.00

6

RL 7.22

5

NEWENCLOSEDGROUNDFLOOR7,810 A.H.D.

GARAGE

RUMPUS /GUEST

BATHROOM

LAUNDRY

UNDERCROFT

40.2

34m

,0°

0' 0

"

20.117m,90° 0' 0"

40.2

34m

,18

0° 0

' 0"

20.117m,270° 0' 0"

Lot 54RP702028

G E O R G E S T R E E T

55RP702028

53RP702028

1

RL 7.04

3

RL 7.04

2

RL 7.03

3

RL 7.02

0

RL 6.87

1

RL 6.88

6

RL 7.01

2

RL 7.01

6

RL 7.00

3

RL 6.88

9RL 6

.856

RL 7.01

3

RL 7.00

5

RL 7.03

0

RL 7.07

8

RL 7.05

3RL 7

.104

RL 7.13

1

RL 7.23

5

RL 7.21

2

RL 7.16

5

RL 7.19

4

RL 7.21

7

RL 7.22

1

RL 7.23

6

RL 7.24

6

RL 7.24

1

RL 7.17

6

RL 7.13

1

RL 7.11

6

RL 7.06

4

RL 7.10

8

RL 7.18

7RL 7

.217

RL 7.31

5 7.210

RL 7.13

3

RL 7.23

4RL 7

.308

RL 7.30

8

RL 7.78

3

RL 7.80

8

RL 7.16

4

RL 7.26

8RL 7.17

7

RL 7.22

4

RL 7.18

8

RL 7.07

9RL 7.09

0

RL 7.14

8RL 7

.123

RL 7.12

5RL 7

.104

RL 7.13

6

RL 7.17

7

RL 7.15

6RL 7

.191

RL 7.15

0

RL 7.12

5

RL 7.03

8

RL 7.59

4

RL 7.01

3

RL 7.03

1RL 7

.105

RL 7.17

8

RL 7.16

6

RL 7.13

1

RL 7.14

9

RL 7.17

2

RL 7.16

5

RL 7.16

6

RL 7.13

3

RL 7.15

5

RL 7.15

7RL 7.13

2RL 7.44

1

RL 7.03

9

RL 7.03

7

RL 7.03

7

RL 7.03

0

RL 7.02

0

RL 7.72

4

RL 7.72

4

RL 8.73

8

RL 7.02

7

RL 7.02

2

RL 7.06

9

RL 7.11

7

RL 7.11

1

RL 7.04

1

RL 7.11

6

RL 7.08

3

RL 7.16

0RL 7.17

7

RL 7.17

4

RL 7.18

9

RL 7.22

7

RL 7.23

1

RL 7.01

1

RL 7.09

8

RL 7.05

6

RL 6.85

3

RL 6.85

4RL 7

.001

WM

ELEC

UNDERCROFT

EXISTINGPOOL & DECK

TURFED AREA

Existing tree to remain

Approximatelocation ofexisting sewer

Exist

ing co

ncre

te pa

th

Exist

ing co

ncre

te pa

th

Existing treeto remain

Existing treeto remain

Additional 10.9m²enclosed floor areaon First Floorshown dashed

RL 7.00

6

RL 7.22

5

EXISTINGUNDERCROFT7,200 A.H.D. Approx.

GUEST

BATH

LDRY

STORE

GARAGE

RL 2,000

GENERAL NOTES

DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.

RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.

Existing RL

New RL+ R

L 7.40

0

EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.

Site boundary

SITE PLAN PROPOSED

0mm 2000 4000 10000

SCALE 1:200 @ A3

Project North

SITE PLAN EXISTING

0mm 2000 4000 10000

SCALE 1:200 @ A3

Project North

Page 3: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.01project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEDEMOLITION GROUND FLOOR PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

RL 2,000

GENERAL NOTES

DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.

RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.

Existing RL

New RL+ R

L 7.40

0

EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.

Site boundaryWall to be demolishedExisting wallNew wall

Remove existing stone& brick walls

Remove existing walls& doors shown dashed

Remove existing columnsthroughout ground floor. Tobe replaced with steelcolumns. Refer toStructural Eng. drawings &details for sizing &connection details

Remove existing bathroomfixtures & cap off drainage

Remove existingconcrete slabs toundercroft area

T.B.C.

Remove & salvageexisting timber batteninfill panels

Existing timber stairs &balustrade to be lifted tosuit new first floor height

Remove existing carport,including roller door &associated columns

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg. Col. Extg.Col. Extg.

Col.

Extg.Col.

Extg.Col.

Existing timber battenarchway infill panels tobe retained & re-used

Remove existingcolumns, stud infills &timber batten archwayinfill panels

Existing timber stairs &balustrade to remain

Existing timber battenfence & gate to be removed

Remove existing concreteslabs. Confirm extent to beremoved on site

Exist

ing la

ndsc

aping

to re

main

Existing turf

Existing turf

Exist

ing la

ndsc

aping

to re

main

ExtgGas

55RP702028

53RP702028

Existing concreteslab to be removed

Remove & salvage existingtimber batten infill panels

SITE

BOU

NDAR

Y

SITE

BOU

NDAR

Y

Relocate existing fence &gate. Refer to A2.04 fornew location

Remove existing hotwater system

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.Extg.Col.

Extg.Col.

Extg.Col.Extg.

Col.Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Existing concretepath to remain

Existing

concr

ete

path to

remain

Remove all existingconcrete paths

Remove section ofconcrete path

Protect extg NBNbox & reinstate

Remove existing concrete

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1DEMOLITION GROUND FLOOR

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

Page 4: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.02project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEDEMOLITION FIRST FLOOR PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

RL 2,000

GENERAL NOTES

DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.

RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.

Existing RL

New RL+ R

L 7.40

0

EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.

Site boundaryWall to be demolishedExisting wallNew wall

Remove existing walls& doors shown dashed

Existing timber stairs &balustrade to remain.Raise to match newlevel of building

Remove existing toilet.Remove redundant drainagelines as required.Remove existing floorboardsto this area

Existing timber deck &roof to remain. Removebox gutter betweendeck roof & house roof

Existing Kitchen joineryto be removed

Existing bathroom walls,joinery & fixtures to beremoved

Existing wardrobe tobe removed

Existing timber stairs &balustrade to be lifted withthe rest of the house

Remove existing carport,including roller shutter &associated columns

SITE

BOU

NDAR

Y

SITE

BOU

NDAR

Y

Line o

f roo

f ove

r

Line o

f roo

f ove

r

Line of roof over

Line of roof over

Line of roof over

Retain existing sunhood

Existing sunhoodsto be removed

Retain existing sunhood

Retain existing sunhood

Existing timber framedexternal wall removed. Referto sections & elevations forextent of removal. Salvagewindows. All existingweatherboards removed areto be salvaged for re-use inthe project if viable

Remove existing door

Existing bathroom doorto be removed and re-used for new bathroom

Existing doors to bere-hung to opentowards bedroom

All carpet throughout to beremoved

All carpet throughout to beremoved

Remove existing walllining to reveal T&Gboarding behind

Existing hinged door tobe removed and re-used as front entry door

Remove & salvage existinghinged door

Existing walls removedto hight of 2100 A.F.L.

Section of wall above 2100 tobe retained & modified. Referto bedroom internalelevations & seek advice fromstructural engineer.

Section of floor to beremoved for new stairs

Remove sections ofexisting wall. Refer to1/A4.07 for extentRemove sections ofexisting wall. Refer to5/A4.06 for extent

Modify existing casementwindow to accomodate newinternal stud wall to Bathroom

Removeextg A/C Remove

extg A/C

Removeextg A/C

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1DEMOLITION FIRST FLOOR

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

Page 5: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.03project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEPROPOSED SLAB SETOUT PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

1,265 3,375 3,625 4,040

12,305

2,250

1,200

300

300 50

5

2,600

1,140

2,225

1,200

60030

030

01,1

05

4,000 600 1,820 1,180

7,810

7,810

7,785

7785

77857,785 7,785

7,260

7,167

7,263

7,200

-592

7,220

7,152

7,332

7,106

7,630

7,7607,610 7,460

7,310

7,760

1A2.03

5A2.03

55RP702028

53RP702028

col.col. col. col. col. col. col.

col.

col.

col.

col.

col.col.

col.col.

col.

col.

col.

col.

col. col.

col.

col.

col.

col.

col.

col. col.col.

col.

col.col.

col.

col.

col.

col. col. col.

col.col.

50

50

50

Step

FALL

Max.

1:4

FALLExisting concrete path

Polished concrete to areashown hatched (bathroom& rumpus).

Stairsup

Stairsup

Refer to structural engineersdrawings and details for more info onsteel columns & conrete slab.

DRIVEWAYExposed Aggregate

Step

New concrete pathto finish flush withexisting concrete

FALL

New exposedaggregate concretedriveway. Providemax. 1:4 grade fromnatural ground levelto internal floorlevel. Provide gradetransitions toprevent vehiclescrapage

Gard

en B

ed

GardenBed

FALL

Max.

1:8FA

LLMa

x. 1:8

FALL

Line of footing under shown dashed

Provide setdown in concrete slab fornew aluminium framed sliding doorthreshold track

Existing concretepath to remain

Existing

concr

ete

path to

remain

400 x 400 concrete blockplinths to base of existingtimber columns

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg. Col. Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

NewCol.

Extg.Col.

Extg.Col.

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1

7,810 7,810

7,810

4A2.03

2A2.03

3A2.03

190620 190 1,033 190 420 190

Concrete masonry wallswith capping blocks. Referto Structural Engineer'sdrawings for details

R.L. 7,810

R.L. 8,160

R.L. 7,220

R.L. 7,785

R.L. 8,160

R.L. 7,220

190 2,110 190 1,843 190 420

Concrete masonry wallswith capping blocks. Referto Structural Engineer'sdrawings for details

R.L. 7,785

R.L. 8,160

Concrete masonry wallswith capping blocks. Referto Structural Engineer'sdrawings for details

R.L. 7,785

Concrete slabRefer to Structural Eng. details

Timber stud wall

External cladding

Sub-floor wallsRefer to Structural Eng. details

Natural ground level

Compacted fill

Footings shown indicative only.Refer to Structural Eng. drawingsfor details

SLAB SETOUT PLAN

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

SECTION S1

0mm 500 1000 2500

SCALE 1:50 @ A31-

SECTION S3

0mm 500 1000 2500

SCALE 1:50 @ A33-

SECTION S2

0mm 500 1000 2500

SCALE 1:50 @ A32-

SECTION S4

0mm 500 1000 2500

SCALE 1:50 @ A34-

STANDARD SLAB EDGE

0mm 200 400 1000

SCALE 1:20 @ A35-

Page 6: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.04project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEPROPOSED GROUND FLOOR PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

RL 2,000

GENERAL NOTES

DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.

RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.

Existing RL

New RL+ R

L 7.40

0

EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.

Site boundaryWall to be demolishedExisting wallNew wall

WG04

WG10

WG07

WG09

WG08

WG06

WG05

DG02

WG01

DG03

DG04

DG01

F WM CD

01020304050607080910111213

DG05

DG06

DG07

DG08

DG10

WG02

WG03

DG09

N

E

W

1A3.08

1A3.08

1A3.07

1A3.07

1A3.05

1A3.05

1A3.06

1A3.06

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg. Col. Extg.Col. Extg.

Col.

Extg.Col.

Extg.Col.

Exist

ing la

ndsc

aping

to re

main

Existing turf

Existing turf

Exist

ing la

ndsc

aping

to re

main

EXISTINGUNDERCROFT

STORAGE

RUMPUS / GUEST

BATHROOM

UNDERCROFT

GARAGE

ExtgGas

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.New

Col.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

LAUNDRY

Cup'd under stair

55RP702028

53RP702028

RL 7.23

5

RL 7.21

2

RL 7.19

4

RL 7.22

1

RL 7.23

6

RL 7.24

1

RL 7.17

6

RL 7.13

1

RL 7.21

7

RL 7.31

5

7.210

RL 7.30

8

RL 7.18

8

RL 7.14

8

RL 7.12

5

RL 7.10

4RL 7

.136

RL 7.17

7

RL 7.19

1RL 7

.150

RL 7.12

5

RL 7.03

8

RL 7.17

8

RL 7.16

6

RL 7.13

1

RL 7.17

2

RL 7.16

5

RL 7.16

6

RL 7.13

3

RL 7.15

5

RL 7.15

7

RL 7.03

7

RL 7.02

7

RL 7.06

9

RL 7.11

7

RL 7.11

1

RL 7.11

6

RL 7.08

3

RL 7.16

0

RL 7.17

4RL 7

.231

DRIVEWAY

Concrete

Concrete

NewCol.

Extg.Col.

NewCol.

Polished Concrete

Polished Concrete

Concrete

Exposed Aggregate

New concrete stairtreads at base ofexisting timber stairs

New timber fence &gate

NewCol.

NewCol. New

Col.

SITE

BOU

NDAR

Y

SITE

BOU

NDAR

Y

R.L. 7810

MSBDB

New timberfence & gate

Ground floor to beenclosed. Internalpartitons to be removedas per demolition plan

Column faces to grid

R.L. 7810

R.L. 7810

R.L. 7810

ConcreteR.L. 7785

Existing Concrete

Existing concretepath to remain

Existing

concr

ete

path to

remain

New concrete plinths toprovide fixing points forexisting raised columns.Approx. 600 high -confirm on site

Extg.Col.

NewCol. Work bench, open under.

Constructed from recycledhardwood palings fromhouseNew

Col.NewCol.

NewCol.

Location of futureA/C/ condenser.Allow power

Full h

t cup

d's

Open

shelv

ing

Refer to internalelevations for joinerydetails

Refer to internalelevations for joinerydetails

90

90

90

90

90

90

90

90

90

90909090

90 90

90

909090

90

90

90

9090

90

Reinstate extg NBNbox. Location TBC

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1

NewCol.

RL 7.00

6

RL 7.22

5

W000

D000

LEGEND - PROPOSED PLANDownpipe - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dp

Drain - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dr

Column - Refer to Structural Engineer's documentation.col.

Floor Waste Gate - Fall tiles into floor waste.fwg

New Door Number - Refer to Door Schedule

New Window Number - Refer to Window Schedule

90

Stud wall - 90 x 45 studs.Provide dressed hardwood studs where exposed.

70

Stud wall - 70 x 35 studs.Provide dressed hardwood studs where exposed.

Refer to internal & external elevations for all walllinings & external claddings.

DOOR SCHEDULE - GROUND FLOORAll dimensions to be confirmed on site prior to manufacture.Door No. Description

DG.01

DG.02

DG.03, 04

DG.05

DG.06

DG.07

DG.08

DG.09, 10

2200 x 2700 B&D roller door (or equal approved) with motor& remote. Colour to be confirmed.

2165 x 1730 Aluminium framed sliding glass door, XO

2175 x 900 (size to be confirmed) face sliding timber door.Paint finish. Provide 'Brio' Open Square Rail sliding system.

2100 x 2400 Custom made, double sliding door. Provide 50 x50 aluminium frame, clad externally with 'Ampelite' WebglassGC 5 rib profile, Opal colour. Provide 'Brio' Single Run 180sliding system.

2100 x 1200 (similar to DG.04)

2100 x 1000 (similar to DG.04)

2100 x 950 (size to be confirmed) custom made hinged door.Provide 50 x 50 aluminium frame, clad externally with'Ampelite' Webglass GC 5 rib profile, Opal colour.

2040 x 80 Cavity sliding door. Paint finish

WINDOW SCHEDULE - GROUND FLOORAll dimensions to be confirmed on site prior to manufacture.Window No. Description

WG.01

WG.02

WG.03

WG.04

WG.05, 06, 07

WG.08, 09, 10

1200 x 1475 Aluminium framed sliding glass window, XO900 sill, 2100 head. Grey tint glass.

900 x 1120 Aluminium framed sliding glass window, XO1200 sill, 2100 head. Frosted glass.

1600 x 600 Aluminium framed fixed glass window0 sill, 1600 head. Grey tint glass.

1600 x 450 Aluminium framed fixed glass window0 sill, 1600 head. Grey tint glass.

555 x 405 Aluminium framed louvre window0 sill, 555 head. Grey tint glass.

555 x 510 Aluminium framed louvre window0 sill, 555 head. Grey tint glass.PROPOSED GROUND FLOOR

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

NOTE - WALL LININGS & STUDSRefer to room elevations for extent of wall linings.Essentially all external & internal walls except whereshown (Bathroom, Laundry & parts of Rumpus) are to beun-lined & studs are to be exposed.All new studs are to be seasoned hardwood and will beleft unfinished.Noggings are to be in line (not staggered) and whereshown on internal elevations.

Page 7: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.05project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEPROPOSED FIRST FLOOR PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

RL 2,000

GENERAL NOTES

DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.

RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.

Existing RL

New RL+ R

L 7.40

0

EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.

Site boundaryWall to be demolishedExisting wallNew wall

FDW

W109

W108

D102

W107 D1

01

D103 D1

04

W104

W106

W105

W103 W1

02W101

D105

N

E

W

1A3.08

1A3.08

1A3.07

1A3.07

1A3.05

1A3.05

1A3.06

1A3.06

100

1,110

90

KITCHEN

DINING

DECK

LIVING

BATHROOM

BEDROOM 1

BEDROOM 2 BEDROOM 3

STUDY

PLAY ROOM

Col.

Col.

Col.

Col.

Col. Col. Col.

Col.

Col.

Robe

Full ht cupd'sWC

ExtgTimber

New Carpet

New Carpet

New CarpetNew Carpet

New Carpet

Re-use existingcasement windows

Re-use existing casementwindow. New timber framed,fixed glass windows adjacent

Extg Timber

Extg Timber

Extg Timber

SITE

BOU

NDAR

Y

SITE

BOU

NDAR

Y

Line o

f roo

f ove

r

Line o

f roo

f ove

r

Line of roof over

Line of roof over

Full h

t cup

d's

Built-in bedDrawers under

Bench open underMobilebench

Bench open under

Full ht cupd's

Full ht cupd's

Drawer

Drawer

Benc

h cup

bd's

unde

r

Full htcupd

Full h

t cup

d's

Bench cupbd's under

Refer to internalelevations for joinerydetails

Refer to internalelevations for joinerydetails

Refer to internalelevations for joinerydetails

extg door

extg

wind

owex

tgwi

ndow

extg

wind

ow

extg window

extg window

extg window

extg

wind

ow

extg

wind

ow

extg

wind

ow

extg door

extg door

extg door

extg door extg door

extg

door

ExtgCol.

ExtgCol.

ExtgCol.

ExtgCol.

ExtgCol.ExtgCol.

ExtgCol.

New balustrade

Robe

Extg Timber

70

70

90

9090

90

90

90

9090

90

70

70

70

70

New aluminium screen

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1

W000

D000

LEGEND - PROPOSED PLANDownpipe - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dp

Drain - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dr

Column - Refer to Structural Engineer's documentation.col.

Floor Waste Gate - Fall tiles into floor waste.fwg

New Door Number - Refer to Door Schedule

New Window Number - Refer to Window Schedule

90

Stud wall - 90 x 45 studs.Provide dressed hardwood studs where exposed.

70

Stud wall - 70 x 35 studs.Provide dressed hardwood studs where exposed.

Refer to internal & external elevations for all walllinings & external claddings.

DOOR SCHEDULE - FIRST FLOORAll dimensions to be confirmed on site prior to manufacture.Door No. Description

D1.01

D1.02

D1.03

D1.04

D1.05

Existing door relocated from Kitchen. Modify existing openingto suit.

2100 x 1350 Timber framed hinged glass door with sidelight.Grey tint glass.

Existing hinged double door, re-hung in same location toswing inward towards Bedroom 1.

2040 x 720 hinged door. Paint finish.

Existing hinged door relocated from existing Bathroom.

WINDOW SCHEDULE - FIRST FLOORAll dimensions to be confirmed on site prior to manufacture.Window No. Description

W1.01

W1.02

W1.03

W1.04

W1.05

W1.06

W1.07

W1.08

W1.09

Existing window relocated.

Existing window relocated.

1000 x 600 Timber framed fixed window. Paint finish toframe.1100 sill, 2100 head. Grey tint glass.

1000 x 570 Timber framed fixed window. Paint finish toframe.1100 sill, 2100 head. Grey tint glass.

Existing window relocated.

1000 x 570 Timber framed fixed window. Paint finish toframe.1100 sill, 2100 head. Grey tint glass.

450 x 600 (Size to be confirmed) aluminium framed fixedwindow where A/C unit removed. Grey tint glass.

1125 x 470 Timber framed window. Modify existingcasement window.

1125 x 1395 Timber framed window. Modify existingcasement window.PROPOSED FIRST FLOOR

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

NOTE - WALL LININGS & STUDSRefer to room elevations for extent of wall linings.Essentially all external & internal walls except whereshown (Bathroom, Laundry & parts of Rumpus) are to beun-lined & studs are to be exposed.All new studs are to be seasoned hardwood and will beleft unfinished.Noggings are to be in line (not staggered) and whereshown on internal elevations.

Page 8: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.06project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEPROPOSED ROOF PLAN

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

RL 2,000

GENERAL NOTES

DIMENSIONSAll dimensions are to structural elements unlessnoted otherwise. Refer to Room Details andWall Type Schedule for finishes.

RAISING & RE-STUMPING OF BUILDINGAll existing timber columns to undercroft area to be replacedwith new columns as documented. Refer to Structural Eng.drawings.First floor level of building to be raised with a finishedfloor level of R.L. 10.410.Ground floor to be enclosed as per floor plans with afinished floor level of R.L 7.810.Contractor to provide all necessary scaffolding & allow forall required materials & equipment associated with the re-stumping & raising of the building.

Existing RL

New RL+ R

L 7.40

0

EXISTING HARDWOOD STUMPS & PALINGSAll existing hardwood stumps & palings to beremoved & salvaged for either re-use or sale. Only asmall no. of palings to be salvaged - refer to noteswhere palings are to be re-used.

Site boundaryWall to be demolishedExisting wallNew wall

N

E

W

1A3.08

1A3.08

1A3.07

1A3.07

1A3.05

1A3.05

1A3.06

1A3.06

Patch existing Deck roofand House roof wherebox gutter removed

Line of building under

New section of roof overfirst floor extension

Existing house roof

Existing Deck roof

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1

Line of building under

Line of building under

Line of building under

Line o

f buil

ding u

nder

W000

D000

LEGEND - PROPOSED PLANDownpipe - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dp

Drain - refer to Hydraulics drawings for detail.Locate existing stormwater services and connect info.dr

Column - Refer to Structural Engineer's documentation.col.

Floor Waste Gate - Fall tiles into floor waste.fwg

New Door Number - Refer to Door Schedule

New Window Number - Refer to Window Schedule

90

Stud wall - 90 x 45 studs.Provide dressed hardwood studs where exposed.

70

Stud wall - 70 x 35 studs.Provide dressed hardwood studs where exposed.

Refer to internal & external elevations for all walllinings & external claddings.

ROOF PROPOSED

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

Page 9: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.07project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEPROPOSED GROUND FLOOR RCP

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg.Col.

Extg. Col. Extg.Col. Extg.

Col.

Extg.Col.

Extg.Col.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

NewCol.

Cup'd under stair

NewCol.

Extg.Col.

NewCol.

NewCol.

NewCol. New

Col.

Extg.Col.

NewCol.

NewCol.

NewCol.

NewCol.

New FC ceilingCH 2285

Paint finish

New grooved ply ceilingCH 2410

Paint finishNewfan

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1

NewCol.

PROPOSED GROUND FLOOR RCP

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

NOTE - LIGHTINGAll new & existing lighting to be discussed & confirmed onsite unless noted specifically on drawings.

Page 10: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A2.08project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEPROPOSED FIRST FLOOR RCP

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

Repair rotten timber inexisting soffit

Col.

Col.

Col.

Col.

Col. Col. Col.

Col.

Col.

extg door

extg

wind

owex

tgwi

ndow

extg

wind

ow

extg window

extg window

extg window

extg

wind

ow

extg

wind

ow

extg

wind

ow

extg door

extg door

extg door

extg door extg door

extg

door

ExtgCol.

ExtgCol.

ExtgCol.

ExtgCol.

ExtgCol.ExtgCol.

ExtgCol.

New plasterboard ceilingCH 2300Paint finish

New plasterboard ceilingOn rakePaint finish

Extg ceilingExtg ceiling

Extg ceiling

Extg ceiling

Extg rakedceilingExtg ceiling

Extg ceiling

Extg soffit

New mezzanine floorNew high level rakedplasterboard ceiling.Paint finishExtg raked

ceiling

Extg rakedceiling

Extg rakedceiling

Extg soffit

A A

B B

C C

D D

E E

F F

5

5

4

4

3

3

2

2

1

1PROPOSED FIRST FLOOR RCP

0mm 1000 2000 5000

SCALE 1:100 @ A3

Project North

NOTE - LIGHTINGAll new & existing lighting to be discussed & confirmed onsite unless noted specifically on drawings.

Page 11: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A3.01project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCENORTH ELEVATION

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

DG05 06

DG07DG

WG01

W105

W106

W104W1

01W102

EXDP

EXDP EXDP

EXDP

DP

DP

DPDP

DP

Boun

dary

Boun

dary

Sliding doorsRefer to schedule

Flashing to Ampelite /Weatherboard junction

Proposed Ground Floor Lvl 0 (R.L. 7.810)

Proposed First Floor Lvl 2,600 (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

EC01

EC01EC01

EC01

EC02

EC02 EC02

CB01 CB01 CB01CB01

ECEXECEX ECEX

EXDP

EXVP

EXDP

EXDP

EXDP

EXDP

EXVP

Boun

dary

Boun

dary

Remove existing timberpaling infill panels.Salvage for re-use

Remove existing columnsthroughout ground floor -refer to Proposed Plan forlocations of new columns

Existing timber stairs &balustrade to be raised

Existing timber battenfence & gate to remain

Existing timber framed externalwall & associated windows &doors to be removed

Existing timber deck & deckroof to be raised. Remove boxgutter between deck roof &house roof

Proposed Ground Floor Lvl (R.L. 7.810)

Proposed First Floor Lvl (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)

ECEX

EC01

EC02

CB01

GP

DP

NORTH ELEVATION PROPOSED

0mm 1000 2000 5000

SCALE 1:100 @ A32-

NORTH ELEVATION EXISTING

0mm 1000 2000 5000

SCALE 1:100 @ A31-

Page 12: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A3.02project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCESOUTH ELEVATION

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

DG02

DG01

WG10

WG07

WG04

WG02

WG09

WG08

WG06

WG05

D101

EXDP

EXDP

EXDP

EXDP

Boun

dary

Boun

dary

CB01 CB01CB01

Flashing to Ampelite /Weatherboard junction

New location ofexisting door

New roller door.Refer to schedule

New aluminium screen

Proposed Ground Floor Lvl 0 (R.L. 7.810)

Proposed First Floor Lvl 2,600 (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

ECEX ECEX

ECEX ECEX ECEX

EC01

EC01

EC02

ECEX

ECEX

EXDP

EXDPEXDP

EXDP

EXVP

Boun

dary

Boun

dary

Existing timber stairs &balustrade to be relocated tosuit new first floor height

Remove existing carport,including roller shutter &associated columns

Remove existingcolumns, stud infills &timber batten archwayinfill panels

Existing timber battenfence & gate to remain

Remove existing timber palinginfill panels. Salvage for re-useRemove existing columns throughoutground floor - refer to Proposed Planfor locations of new columns

Proposed Ground Floor Lvl (R.L. 7.810)

Proposed First Floor Lvl (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)

ECEX

EC01

EC02

CB01

GP

DP

SOUTH ELEVATION PROPOSED

0mm 1000 2000 5000

SCALE 1:100 @ A32-

SOUTH ELEVATION EXISTING

0mm 1000 2000 5000

SCALE 1:100 @ A31-

Page 13: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A3.03project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEEAST ELEVATION

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

W103W1

08W109

EXDP

EXDPDP

DP DP

DP

Flashing to Ampelite /Weatherboard junction

New aluminium screen

Proposed Ground Floor Lvl 0 (R.L. 7.810)

Proposed First Floor Lvl 2,600 (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

ECEXEC01

EC02

ECEXEC01

EC02

ECEX

CB01 CB01

EXDP EXDP

EXVP

EXVP

EXDP

EXDPEXDPEXVP

Existing timber stairs &balustrade to be relocated tosuit new first floor heightRemove existing carport,including roller shutter &associated columns

Remove existing timber palinginfill panels. Salvage for re-use

Remove existing columns throughoutground floor - refer to Proposed Planfor locations of new columns

Remove existing timber paling infillpanels. Salvage for re-use

Existing timber framed externalwall & associated windows &doors to be removed

Existing timber deck & deckroof to be raised

Remove box gutter betweendeck roof & house roofExisting timber framed externalwall & associated windows &doors to be removed

Remove existing A/C unit& infill wall

Remove existing A/C unit& replace with new

Modify existing casementwindow to accomodate newbathroom layout

Remove existing vent pipes

Remove existingdownpipe

Remove existing vent pipe

Proposed Ground Floor Lvl (R.L. 7.810)

Proposed First Floor Lvl (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)

ECEX

EC01

EC02

CB01

GP

DP

EAST ELEVATION PROPOSED

0mm 1000 2000 5000

SCALE 1:100 @ A32-

EAST ELEVATION EXISTING

0mm 1000 2000 5000

SCALE 1:100 @ A31-

Page 14: GEORGE ST RESIDENCE DWG INDEX DWG - … · Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Extg. Col. Existing timber

revision: A - WIPdrawing number: A3.04project number:PENDING

date: 29/05/2015

F O R A P P R O V A L

GEORGE ST RESIDENCEWEST ELEVATION

78 George Street, Mackay, QLD, 4740 0 5 10 15 25 50

08DG

WG03

D102EXDP EXDP

EXDP

EXDP

EXDPDP W107

Flashing to Ampelite /Weatherboard junction

New window where A/Cunit removed

Future A/C unit. Allow power

Reinstate extg NBN box.Location TBC

Proposed Ground Floor Lvl 0 (R.L. 7.810)

Proposed First Floor Lvl 2,600 (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

ECEX

EC02

CB01

ECEX

ECEX

ECEX ECEX

ECEX

EC01 EC01

CB01 CB01

ECEX

EXVP

EXDPEXDP

EXDPEXDP

EXDPEXDP

Existing timber battenfence & gate to remain

Existing timber stairs &balustrade to be raised

Existing timber stairs &balustrade to be relocated tosuit new first floor heightRemove existing carport,including roller shutter &associated columns

Remove existing timber palinginfill panels. Salvage for re-use

Remove existing columns throughoutground floor - refer to Proposed Planfor locations of new columns

Existing timber deck & deckroof to be raised

Remove box gutter betweendeck roof & house roof

Existing timber framed externalwall & associated windows &doors to be removed

Remove existing A/C unit

Proposed Ground Floor Lvl (R.L. 7.810)

Proposed First Floor Lvl (R.L 10.410)

Extg Ground Floor Lvl (Approx. R.L. 7.200)

Extg First Floor Lvl (Approx. R.L. 9.450)

LEGEND - EXTERNAL FINISHESExternal Cladding Existing:Existing hardwood weatherboard cladding.External Cladding Type 1:Weatherboards: Hardwood weatherboards either salvagedfrom demolition works, or provide new boards speciallymachined to match existing.External Caldding Type 2:'Ampelite' Webglass GC 5 rib profile, Opal colour. Fixed asper manufacturers recommendations.Concrete masonry blockwork: standard grey colour.Grooved plywood:Boral PanelWood 7mmDownpipe (EX denotes existing)

ECEX

EC01

EC02

CB01

GP

DP

WEST ELEVATION PROPOSED

0mm 1000 2000 5000

SCALE 1:100 @ A32-

WEST ELEVATION EXISTING

0mm 1000 2000 5000

SCALE 1:100 @ A31-