GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified...

20
TM GENESIS SELECTION GUIDE FOURTH EDITION TM

Transcript of GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified...

Page 1: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

TM

GENESIS SELECTION GUIDEFOURTH EDITION

TM

Page 2: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

Global Headquart e rsP. O. B ox 14145 Reading,PA 196212-4145U S ATe l : + 1 - 6 1 0 - 2 0 8 - 1 9 9 1

+ 1 - 8 0 0 - 5 3 8 - 3 6 2 7Fa x : + 1 - 6 1 0 - 3 7 2 - 8 6 1 3

EnerSys EMEAB ru s s e l s, BelgiumTe l : +32 (0)2 247 94 47

EnerSys AsiaGuangdong, ChinaTe l : +86-755-2689 3639

Page 3: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 Certified

Publication No. US-GPL-SG-001 March 2003

TABLE OF CONTENTS

Company background

EnerSys, Inc.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

S e rvices and applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Technical information

Capacity as a function of temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

State of charge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Storage time as a function of temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Voltage regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

C h a r g i n g. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

GENESIS B a t t e r i e s

GENESIS product family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

EP performance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 0

EP mechanical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1

70EP performance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2

70EP mechanical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3

VP performance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4

VP mechanical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 5

GENESIS constant current (CC) and constant power (CP) discharge graphs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 6

Quick reference list

Standard product listing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .inside back cover

GENESIS SELECTION GUIDE

Page 4: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

ENERSYS, INC.EnerSys, Inc. is the world’s largest industrial battery manufacturer.

Headquartered in Reading, PA, USA, EnerSys has 22 manufacturingand assembly plants, over 7,000 employees, and a worldwide salesand distribution network. A leader in both valve-regulated and floodedlead acid battery technologies, EnerSys is a major supplier to telecom-munications, UPS, data processing, electronic, and material handlingmarkets across the globe.

EnerSys, Inc. operates several of the first lead acid battery plants in the United States to receive the ISO 9001 certificates of registration, covering the company’s product design, manufacturing,a s s e m b l y, and customer service functions. ISO 9001 certification,covering 20 key elements, assures customers that EnerSys has fullydocumented and implemented manufacturing and quality systemsthat are consistently followed.

EnerSys’ environmentally progressive Warrensburg, Missouri plant,home base of the Genesis product lines, covers 320,000 square feet on 33 acres and employs more than 400 people. EnerSys was the first b a t t e ry company in the United States to receive ISO 14001 certification.ISO 14001 focuses on the environmental management system of thebusiness and provides a systematic approach to resource conserv a t i o n .

EnerSys supports its customers through global field sales offices and a select network of authorized Value Added Centers and international representatives and distributors. EnerSys offerstechnical support and customer service unparalleled in the industry.A d d i t i o n a l l y, the sales and support team is committed to meeting and exceeding the individual needs of each customer.

GENESIS SELECTION GUIDE

2

EnerSys’ Warrensburg plant covers 320,000 square feet and is situated on 33 acres

Page 5: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 Certified

Publication No. US-GPL-SG-001 March 2003

GENESIS SELECTION GUIDE

3

VALUE-ADDED SERVICESIn addition to our manufacturing capability, EnerSys is proud to

provide its customers with the following serv i c e s :

• customized manufacturing design• battery recycling• on-line Internet technical information• charging support• product testing• on-site technical seminars• battery samples• application engineering• technical documentation

A P P L I C AT I O N SBatteries from EnerSys’ “pure lead-tin” family are used in a wide

variety of standby and portable/cyclic applications including those in:

• telecommunications• electronics• uninterruptible power supplies• defense installations• aviation• computer back-up• electric vehicles• medical equipment• solar power• lawn and garden equipment• specialty engine start

Page 6: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

F E ATURES AND BENEFITSSealed pure-lead cells were invented by the Gates Corporation in

1973. The purity of the materials used is key to supporting the G E N E S I Sp e rformance benefits. A longer service life, meaning fewer replace-ments and the cost associated, combined with higher reliability andfewer system failures, result in a lower long-term cost of ownership to the end user or equipment owner.

What are the advantages of EnerSys technology?

POWER DENSITY—Per unit weight, the power provided by pure lead-tin products offers the greatest high-rate power densityfor your energy dollar. GENESIS’ greater volumetric power allowsengineers to consider more energy-supporting features or designs m a l l e r, lighter packages.

In high-rate and pulse discharge applications, E n e r S y s’ G E N E S I Sproducts offer the best performance available when compared with com-petitive product in applications at less than 100 minutes of discharge.

CYCLE LIFE—Compared to competitive lead products (offering up to 200 full cycles), pure lead-tin batteries provide 50% to200% greater full cycle capability. G E N E S I S product will deliver 400cycles (100% DOD, C/5). And, because GENESIS incorporates a highvent-pressure design, E n e r S y s ’ products experience no “dry out” failuremode from repeated recharges.

F L O AT LIFE—Conventional sealed-lead batteries vary greatlyin specified standby life: from three to six years at 20° C, C/20.G E N E S I S,h o w e v e r, offers a ten-year design life at 25° C, C/5, to 80% of rated capacity. At 20° C, GENESIS offer a fifteen-year design life.

HIGH STABLE VOLTAGE DELIVERY —The high stable voltaged e l i v e ry of GENESIS results from its low internal resistance. The flat discharge voltage profile of our batteries, similar to nickel cadmium,combined with our products’ low internal resistance, means our bat-teries are able to discharge and recharge more quickly and efficientlyand offer greater application flexibility. The pure lead-tin cons t r u c t i o nalso gives more watts-per-unit weight at high discharge rates.

WIDEST T E M P E R ATURE RANGE—Due to the product’sstrong construction and high vent pressures, these batteries will m a i n-tain their performance and physical parameters in extreme conditions.At high temperatures, the chemical reaction in a battery that causes

aging is accelerated. Pure lead-tin technology resists that chemical reaction more effectively than alloyed lead, thus allowing a battery tohave a longer service life. At high temperatures, when conventionallead batteries experience internal moisture loss from venting and caseside wall distention, the G E N E S I S,with its steel can (metal jacket) and high vent pressure, does not experience these life-robbing conditions. GENESIS has twice the delivered capacity of conventionalsealed-lead batteries at temperatures below -20° C, offering unparal-leled low-temperature perf o r m a n c e .

GENESIS electrodes are thinner, allowing more electrodes per cell,and therefore greater electrode surface area than conventional sealed-lead, thick electrode batteries. As a result, our batteries can reach ahigh state of charge in fast-charging applications in one-fourth thetime of conventional, sealed-lead, thick-plate batteries. This is 50% to100% overall better performance for your energy dollar.

RUGGED CONSTRUCTION—Due to their strong externalpackaging and internal pure lead-tin composition, EnerSys’ productscan withstand not only extreme temperatures but also harsh usage.

THE PURE LEAD-TIN A D VA N TA G E

6

5

4

3

2

1

GENESIS SELECTION GUIDE

4Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

Page 7: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

G E N E S I S external case for the EP product is constructed from UL 94V-0 rated non-halogenated flame-retardant materials. G E N E S I Sproducts are shock and vibration resistant, designed to offer higher tolerance levels to meet demanding applications, including those inc o m m e rcial and outdoor applications. The company’s focus on battery -case integrity and high vent pressure, coupled with pure lead-tin’s low grid-corrosion rate, means GENESIS provide the longest service life possible.

FASTEST RECHARGE—E n e r S y s ’ pure lead-tin chemistryallows GENESIS to offer the shortest recharge times of any sealed-leadb a t t e ry on the market. With pure lead-tin, you can achieve a 95% stateof recharge in less than one hour—without loss of capacity or elec-trolyte using conventional constant-voltage charging techniques.

Flexible charging options are possible with G E N E S I S,as no current limit is required when using a constant voltage charger.

O R I E N TAT I O N / P L A C E M E N T / T R A N S P O RT —Due to the products’ mechanical design, GENESIS can be mounted and operatedin any position, an attractive feature for less accessible areas.

GENESIS offer UL 94V-0 non-halogenated flame-retardant packaging, thus allowing the mounting of systems in sensitive areasand human environments.

Effective September 30, 1995, GENESIS products were classifiedas “nonspillable batteries”, and are excepted from the Department ofTr a n s p o r t a t i o n ’s comprehensive packaging requirements if the follow-ing conditions are satisfied: (1) The battery is protected against shortc i rcuits and is securely packaged and (2) The battery and outer pack-aging must be plainly and durably marked “NONSPILLABLE” or“NONSPILLABLE BAT T E RY”. GENESIS shipments from EnerSysWarrensburg location, will be properly labeled in accordance withapplicable regulations. Packaging changes performed at other loca-tions may require additional labeling, since in addition to the batteryitself containing the required marking, the outer packaging of theb a t t e ry must also contain the required marking: “NONSPILLABLE” or “NONSPILLABLE BAT T E RY”.

GENESIS batteries have been tested and determined to be in com-pliance with the vibration and pressure differential tests contained in49 CFR § 173.159(d).

Because GENESIS are classified as “Nonspillable” and meet theconditions from § 173.159(d), they do not have an assigned UN number nor do they require additional DOT hazard labeling.

The regulation change effective September, 1995, was to clarifyand distinguish to shippers and transporters, all batteries that havebeen tested and determined to be in compliance with the DOTHazardous Material Regulations, the International Civil AeronauticsOrganization (ICAO), and the International Air Transport Association( I ATA) Packaging Instruction 806 and Special Provision A67, andtherefore excepted from all other requirements of these regulationsand classified as a “nonspillable battery ” .

SHELF LIFE—Pure lead-tin batteries have an extremely low self-discharge rate, thus providing extended storage capability whilemaintaining high state-of-charge levels for dependable operation.

G E N E S I S has a shelf life more than two times that of conventionallead batteries. To assure maximum reliability, E n e r S y s r e c o m m e n d sthat all stored batteries be recharged (boost charged) once every 24months or when the open circuit voltage drops to 12.00 volts per b a t t e ry, which-ever occurs earlier. Inventory should be checked more frequently if storage temperature regularly exceeds 25°C.

9

8

7

GENESIS SELECTION GUIDE

5Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

Page 8: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

C A PACITY AS A FUNCTION OF TEMPERATURE FOR GENESIS BAT T E R I E S

S TATE OF CHARGE FOR GENESIS BAT T E R I E S

GENESIS SELECTION GUIDE

6Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

Page 9: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

STORAGE TIME AS A FUNCTION OF TEMPERATURE FOR GENESIS BAT T E R I E S( F U L LY CHARGED BAT T E RY )

V O LTAGE REGULATION FOR GENESIS BAT T E R I E S

GENESIS SELECTION GUIDE

7Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

Page 10: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

CHARGING RECOMMENDAT I O N S :Broadly speaking, a battery may be recharged using either a

constant voltage (CV) charger or a constant current (CC) charger, or a modification of either or both of these.

The exact regime chosen generally depends upon the time andeconomic constraints imposed by the system. Constant currentcharging is widely used in cyclic applications where a recharge mustbe accomplished in a relatively short time period. Constant voltagecharging, where a single voltage level is applied across the batteryterminals, is the most suitable method to recharge G E N E S I S p r o d-ucts. Depending on the CV charger’s current limit, it is possible torecharge these batteries from a 100% discharged condition to betterthan 95% state of charge in less than one hour, using only the cycliccharge voltage.

Constant voltage charging

Constant voltage (CV) charging should be within the followingr a n g e s :

Fast Chargers: 12 volts: 14.7 to 15.0 volts @ 25°C

Float Chargers: 12 volts: 13.5 to 13.8 volts @ 25°C

To avoid thermal runaway in warmer temperatures, and to improvecharge acceptance in colder temperatures, the charger voltage shouldbe compensated by approximately 18 millivolts per battery per degreecentigrade variance from 25°C. This is a negative coefficient, with thevoltage being lowered as the temperature increases, and vice versa.

There is no need to limit the inrush current to the battery during theinitial phase of constant voltage charging. The low internal resistance ofG E N E S I S batteries allows for large inrush current without damage.

Since not all of the charge returned is accepted to replenish theelectro-chemical potential, a good rule of thumb to use is that thecharge returned should be 105% to 110% of the capacity deliveredon the previous discharge.

Most current waveforms are not pure DC nor are they pure sinewaves. Therefore, consult the EnerSys Application Support Departmentfor assistance when evaluating the charger current waveforms for yourspecific application.

GENESIS SELECTION GUIDE

8Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

Page 11: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS SELECTION GUIDE

9Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

GENESIS PRODUCT FA M I LY (All capacities at 10 hr. rate 25°C to 1.67 vpc)

GENESIS EP :D I M E N S I O N S

Internal res. Nominal short B r a s sP r o d u c t Part of fully charged circuit current for L e n g t h W i d t h H e i g h t We i g h t Te r m i n a l( c a p a c i t y ) N u m b e r b a t t e ry mΩ @ 2 5 ° C charged battery in. (mm) in. (mm) in. (mm) lb. (kg) ( m e t r i c )

G 1 3 E P 0 7 7 0 - 2 0 0 7 8 . 5 1 , 4 0 0 A 6 . 9 1 0 3 . 2 8 2 5 . 1 1 3 1 0 . 8 M6 w/ss ( 1 3 A h ) ( 1 7 5 . 5 1 ) ( 8 3 . 3 6 ) (129.87) ( 4 . 9 ) h a r d w a r e

G 1 3 E P X 0 7 7 0 - 2 0 0 3 8 . 5 1 , 4 0 0 A 6 . 9 9 8 3 . 3 6 8 5 . 1 6 5 1 2 . 0 M6 w/ss ( 1 3 A h ) ( 1 7 7 . 7 5 ) ( 8 5 . 5 5 ) (131.19) ( 5 . 4 ) h a r d w a r e

G16EP 0 7 6 9 - 2 0 0 7 7 . 5 1 , 6 0 0 A 7 . 1 5 0 3 . 0 0 5 6 . 6 0 5 1 3 . 5 M6 w/ss ( 1 6 A h ) ( 1 8 1 . 6 1 ) ( 7 6 . 3 3 ) (167.77) ( 6 . 1 ) h a r d w a r e

G 1 6 E P X 0 7 6 9 - 2 0 0 3 7 . 5 1 , 6 0 0 A 7 . 2 6 7 3 . 1 0 7 6 . 6 6 6 1 4 . 7 M6 w/ss ( 1 6 A h ) ( 1 8 4 . 5 8 ) ( 7 8 . 9 2 ) (169.32) ( 6 . 7 ) h a r d w a r e

G 2 6 E P 0 7 6 5 - 2 0 0 1 5 . 0 2 , 4 0 0 A 6 . 5 6 5 6 . 9 2 0 4 . 9 5 7 2 2 . 3 M6 w/ss ( 2 6 A h ) ( 1 6 6 . 7 5 ) ( 1 7 5 . 7 7 ) (125.91) ( 1 0 . 1 ) h a r d w a r e

G 2 6 E P X 0 7 6 5 - 2 0 0 3 5 . 0 2 , 4 0 0 A 6 . 6 3 6 7 . 0 4 9 5 . 0 4 0 2 3 . 8 M6 w/ss ( 2 6 A h ) ( 1 6 8 . 5 5 ) ( 1 7 9 . 0 4 ) (128.02) ( 1 0 . 8 ) h a r d w a r e

G42EP 0 7 6 6 - 2 0 0 1 4 . 5 2 , 6 0 0 A 7 . 7 7 5 6 . 5 2 5 6 . 7 1 5 3 2 . 9 M6 w/ss ( 4 2 A h ) ( 1 9 7 . 4 9 ) ( 1 6 5 . 7 4 ) (170.56) ( 1 4 . 9 ) h a r d w a r e

G 4 2 E P X 0 7 6 6 - 2 0 0 3 4 . 5 2 , 6 0 0 A 7 . 8 6 6 6 . 6 5 9 6 . 8 0 3 3 5 . 1 M6 w/ss ( 4 2 A h ) ( 1 9 9 . 8 0 ) ( 1 6 9 . 1 4 ) (172.80) ( 1 5 . 9 ) h a r d w a r e

G70EP 0 7 7 1 - 2 0 0 1 3 . 5 3 , 5 0 0 A 1 3 . 0 2 0 6 . 6 2 0 6 . 9 3 0 5 3 . 5 M6 w/ss ( 7 0 A h ) ( 3 3 0 . 7 1 ) ( 1 6 8 . 1 5 ) (176.02) ( 2 4 . 3 ) h a r d w a r e

G70EPX 0 7 7 1 - 2 0 0 3 3 . 5 3 , 5 0 0 A 1 3 . 0 2 0 6 . 6 2 0 6 . 9 3 0 5 6 . 0 M6 w/ss ( 7 0 A h ) ( 3 3 0 . 7 1 ) ( 1 6 8 . 1 5 ) (176.02) ( 2 5 . 4 ) h a r d w a r e

X denotes metal jacket design for extreme dutyAll dimensions, excluding weight, are maximumEP external case material — V-0 rated non-halogenated flame-retardantVP external case material — HB flame rated

GENESIS VP :

D I M E N S I O N S

Internal res. Nominal short B r a s sP r o d u c t Part of fully charged circuit current for L e n g t h W i d t h H e i g h t We i g h t Te r m i n a l( c a p a c i t y ) N u m b e r b a t t e ry mΩ @ 2 5 ° C charged battery in. (mm) in. (mm) in. (mm) lb. (kg) ( m e t r i c )

G 2 6 V P 0 7 6 5 - 3 0 0 1 5 . 0 2 , 4 0 0 A 6 . 5 6 5 6 . 9 2 0 4 . 9 5 7 2 2 . 3 M6 w/ss ( 2 6 A h ) ( 1 6 6 . 7 5 ) ( 1 7 5 . 7 7 ) (125.91) ( 1 0 . 1 ) h a r d w a r e

G 2 6 V P X 0 7 6 5 - 3 0 0 3 5 . 0 2 , 4 0 0 A 6 . 6 3 6 7 . 0 4 9 5 . 0 4 0 2 3 . 8 M6 w/ss ( 2 6 A h ) ( 1 6 8 . 5 5 ) ( 1 7 9 . 0 4 ) (128.02) ( 1 0 . 8 ) h a r d w a r e

G42VP 0 7 6 6 - 3 0 0 1 4 . 5 2 , 6 0 0 A 7 . 7 7 5 6 . 5 2 5 6 . 7 1 5 3 2 . 9 M6 w/ss ( 4 2 A h ) ( 1 9 7 . 4 9 ) ( 1 6 5 . 7 4 ) (170.56) ( 1 4 . 9 ) h a r d w a r e

G 4 2 V P X 0 7 6 6 - 3 0 0 3 4 . 5 2 , 6 0 0 A 7 . 8 6 6 6 . 6 5 9 6 . 8 0 3 3 5 . 1 M6 w/ss ( 4 2 A h ) ( 1 9 9 . 8 0 ) ( 1 6 9 . 1 4 ) (172.80) ( 1 5 . 9 ) h a r d w a r e

Page 12: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

10Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

GENESIS EP PERFORMANCE SPECIFICATIONS

UL Recognized Component. Meets UL 1989Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container

Sealed-lead rechargeable battery must be recycled. Contact EnerSys Customer Service for details.

Maximum recommended storage time before recharge—24 months @ 25°C or 2.0vpc, whichever is earlierAtmospheric pressure range—Vacuum to 2 atmospheresTerminal attachment torque for G13EP & G16EP—50 in.-lbs. (5.6 nm)Terminal attachment torque for G26EP & G42EP—60 in.-lbs. (6.8 nm)

* Users planning to use CC should consult the EnerSys Application Support Department

Constant current discharge/amps to 1.67 vpc @ 25°C

C h a r g i n g / Te m p e r a t u r e / L i f e :

CHARGING PER B ATT ERY

Storage & C/5 Cycle life Float life atP r o d u c t s C y c l i c F l o a t d i s c h a r g e C h a r g e 100% DOD 25°C (20°C)

G 1 3 E P, G16EP, CV 14.7–15.0 CV 13.5–13.8 -40°C to +45°C -40°C to +45°C 4 0 0 10 yearsG26EP & G42EP C C * C C * (15 years)

G13EPX, G16EPX, CV 14.7–15.0 CV 13.5–13.8 -40°C to +60°C -40°C to +60°C 4 0 0 10 yearsG26EPX & G42EPX C C * C C * (15 years)

D U R AT I O N

P r o d u c t s 5 min. 10 min. 1 5 m i n . 30 min. 60 min. 90 min. 5 hr. 8 hr. 10 hr. 20 hr.

G13EP 7 0 . 8 4 3 . 6 3 2 . 2 1 8 . 6 1 0 . 4 7 . 3 2 . 5 1 . 6 1 . 3 . 7( 1 3 A h )

G16EP 9 0 . 0 5 4 . 8 4 0 . 1 2 3 . 0 1 2 . 7 8 . 9 3 . 0 2 . 0 1 . 6 . 8( 1 6 A h )

G26EP 1 4 3 . 4 9 0 . 7 6 7 . 4 3 9 . 0 2 1 . 7 1 5 . 1 5 . 0 3 . 2 2 . 6 1 . 4( 2 6 A h )

G42EP 2 1 2 . 0 1 3 8 . 4 1 0 4 . 1 6 0 . 8 3 3 . 8 2 3 . 5 7 . 9 5 . 1 4 . 2 2 . 3( 4 2 A h )

Constant power discharge/watts per battery to 1.67 vpc @ 25°C

D U R AT I O N

P r o d u c t s 5 min. 10 min. 1 5 m i n . 30 min. 60 min. 90 min. 5 hr. 8 hr. 10 hr. 20 hr.

G13EP 7 5 8 . 4 4 8 1 . 8 3 6 1 . 2 2 3 1 . 6 1 2 1 . 2 8 5 . 8 2 9 . 4 1 9 . 2 1 5 . 6 8 . 4( 1 3 A h )

G16EP 9 7 5 . 6 6 0 9 . 6 4 5 3 . 6 2 6 4 . 6 1 9 0 . 2 1 0 5 . 0 3 6 . 0 2 3 . 4 1 9 . 2 1 0 . 2( 1 6 A h )

G26EP 1 5 3 2 9 9 5 7 5 1 4 4 4 2 5 1 1 7 5 . 8 5 9 3 8 3 1 1 6( 2 6 A h )

G42EP 2 2 9 1 1 5 4 0 1 1 7 3 6 9 8 3 9 4 2 7 6 9 4 6 2 5 1 2 8( 4 2 A h )

LIFE EXPECTA N C YT E M P E R ATURE RANGE

Page 13: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

11Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

GENESIS SELECTION GUIDE

GENESIS EP MECHANICAL SPECIFICATIONS (A,B,& C — M A X I M U M )

DIMENSIONS in. (mm)

We i g h tP r o d u c t s A B C D E lb. (kg)

G 1 3 E P 6 . 9 1 0 3 . 2 8 2 5 . 1 1 3 5 . 5 6 0 . 8 1 1 0 . 8( 1 7 5 . 5 1 ) ( 8 3 . 3 6 ) ( 1 2 9 . 8 7 ) ( 1 4 1 . 2 ) ( 2 0 . 6 ) ( 4 . 9 )

G 1 3 E P X 6 . 9 9 8 3 . 3 6 8 5 . 1 6 5 5 . 5 6 0 . 8 1 1 2 . 0( 1 7 7 . 7 5 ) ( 8 5 . 5 5 ) ( 1 3 1 . 1 9 ) ( 1 4 1 . 2 ) ( 2 0 . 6 ) ( 5 . 4 )

G 1 6 E P 7 . 1 5 0 3 . 0 0 5 6 . 6 0 5 5 . 7 4 0 . 6 7 1 3 . 5( 1 8 1 . 6 1 ) ( 7 6 . 3 3 ) ( 1 6 7 . 7 7 ) ( 1 4 5 . 8 ) ( 1 6 . 9 ) ( 6 . 1 )

G 1 6 E P X 7 . 2 6 7 3 . 1 0 7 6 . 6 6 6 5 . 7 4 0 . 6 7 1 4 . 7( 1 8 4 . 5 8 ) ( 7 8 . 9 2 ) ( 1 6 9 . 3 2 ) ( 1 4 5 . 8 ) ( 1 6 . 9 ) ( 6 . 7 )

DIMENSIONS in. (mm)

We i g h tP r o d u c t s A B C D E lb. (kg)

G 2 6 E P 6 . 5 6 5 6 . 9 2 0 4 . 9 5 7 0 . 6 4 1 . 0 6 2 2 . 3( 1 6 6 . 7 5 ) ( 1 7 5 . 7 7 ) ( 1 2 5 . 9 1 ) ( 1 6 . 3 ) ( 2 7 . 0 ) ( 1 0 . 1 )

G 2 6 E P X 6 . 6 3 6 7 . 0 4 9 5 . 0 4 0 0 . 6 9 1 . 1 1 2 3 . 8( 1 6 8 . 5 5 ) ( 1 7 9 . 0 4 ) ( 1 2 8 . 0 2 ) ( 1 7 . 5 ) ( 2 8 . 2 ) ( 1 0 . 8 )

G 4 2 E P 7 . 7 7 5 6 . 5 2 5 6 . 7 1 5 0 . 7 4 0 . 8 7 3 2 . 9( 1 9 7 . 4 9 ) ( 1 6 5 . 7 4 ) ( 1 7 0 . 5 6 ) ( 1 8 . 8 ) ( 2 2 . 0 ) ( 1 4 . 9 )

G 4 2 E P X 7 . 8 6 6 6 . 6 5 9 6 . 8 0 3 0 . 7 9 0 . 9 1 3 5 . 1( 1 9 9 . 8 0 ) ( 1 6 9 . 1 4 ) ( 1 7 2 . 8 0 ) ( 2 0 . 1 ) ( 2 3 . 2 ) ( 1 5 . 9 )

G13 & 16EPShown without metal jacket

G26 & 42EPShown without metal jacket

Page 14: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS 70EP PERFORMANCE SPECIFICATIONS

12Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

UL Recognized Component. Meets UL 1989Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container

Sealed-lead rechargeable battery must be recycled. Contact EnerSys Customer Service for details.

Maximum recommended storage time before recharge—24 months @ 25°C or 2.0vpc, whichever is earlierAtmospheric pressure range—Vacuum to 2 atmospheresTerminal attachment torque for G70EP—60 in.-lbs. (6.8 nm)

* Users planning to use CC should consult the EnerSys Application Support Department

Constant current discharge/amps to 1.67 vpc @ 25°C

C h a r g i n g / Te m p e r a t u r e / L i f e :

CHARGING PER B ATT ERY

Storage & C/5 Cycle life Float life atP r o d u c t s C y c l i c F l o a t d i s c h a r g e C h a r g e 100% DOD 25°C (20°C)

G 7 0 E P CV 14.7–15.0 CV 13.5–13.8 -40°C to +45°C -40°C to +45°C 4 0 0 10 yearsC C * C C * (15 years)

G 7 0 E P X CV 14.7–15.0 CV 13.5–13.8 -40°C to +60°C -40°C to +60°C 4 0 0 10 yearsC C * C C * (15 years)

D U R AT I O N

P r o d u c t s 5 min. 10 min. 1 5 m i n . 30 min. 60 min. 90 min. 5 hr. 8 hr. 10 hr. 20 hr.

G70EP 3 4 2 . 4 2 2 8 . 5 1 7 3 . 4 1 0 2 . 5 5 7 . 4 4 0 . 6 1 3 . 4 8 . 7 7 . 1 3 . 9( 7 0 A h )

Constant power discharge/watts per battery to 1.67 vpc @ 25°C

D U R AT I O N

P r o d u c t s 5 min. 10 min. 1 5 m i n . 30 min. 60 min. 90 min. 5 hr. 8 hr. 10 hr. 20 hr.

G70EP 3 6 8 0 2 5 1 9 1 9 4 0 1 1 7 3 6 7 0 4 8 6 1 6 1 1 0 5 8 6 4 7( 7 0 A h )

LIFE EXPECTA N C YT E M P E R ATURE RANGE

Page 15: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS SELECTION GUIDE

13Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

GENESIS 70EP MECHANICAL SPECIFICATIONS (A,B,& C — M A X I M U M )

DIMENSIONS in. (mm)

We i g h tP r o d u c t s A B C D E lb. (kg)

G 7 0 E P 1 3 . 0 2 0 6 . 6 2 0 6 . 9 3 0 9 . 6 9 2 . 4 5 5 3 . 5( 3 3 0 . 7 1 ) ( 1 6 8 . 1 5 ) ( 1 7 6 . 0 2 ) ( 2 4 6 . 1 3 ) ( 6 2 . 2 3 ) ( 2 4 . 3 )

G 7 0 E P X 1 3 . 0 2 0 6 . 6 2 0 6 . 9 3 0 9 . 6 9 2 . 4 5 5 6 . 0( 3 3 0 . 7 1 ) ( 1 6 8 . 1 5 ) ( 1 7 6 . 0 2 ) ( 2 4 6 . 1 3 ) ( 6 2 . 2 3 ) ( 2 5 . 4 )

Shown without metal jacket

Page 16: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS VP PERFORMANCE SPECIFICATIONS

14Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container

Sealed-lead rechargeable battery must be recycled. Contact EnerSys Customer Service for details.

Maximum recommended storage time before recharge—24 months @ 25°C or 2.0vpc, whichever is earlier

Atmospheric pressure range—Vacuum to 2 atmospheresTerminal attachment torque—60 in.-lbs. (6.8 nm)

* Users planning to use CC should consult the EnerSys Application Support Department

Constant current discharge/amps to 1.67 vpc @ 25°C

C h a r g i n g / Te m p e r a t u r e / L i f e :

CHARGING PER B ATT ERY

Storage & C/5 Cycle life Float life atP r o d u c t s C y c l i c F l o a t d i s c h a r g e C h a r g e 100% DOD 25°C (20°C)

G26VP & CV 14.7–15.0 CV 13.5–13.8 -40°C to +40°C -40°C to +40°C 4 0 0 10 yearsG42VP C C * C C * (15 years)

G26VPX & CV 14.7–15.0 CV 13.5–13.8 -40°C to +50°C -40°C to +50°C 4 0 0 10 yearsG 4 2 V P X C C * C C * (15 years)

D U R AT I O N

P r o d u c t s 5 min. 10 min. 1 5 m i n . 30 min. 60 min. 90 min. 5 hr. 8 hr. 10 hr. 20 hr.

G26VP 1 4 3 . 4 9 0 . 7 6 7 . 4 3 9 . 0 2 1 . 7 1 5 . 1 5 . 0 3 . 2 2 . 6 1 . 4( 2 6 A h )

G42VP 2 1 2 . 0 1 3 8 . 4 1 0 4 . 1 6 0 . 8 3 3 . 8 2 3 . 5 7 . 9 5 . 1 4 . 2 2 . 3( 4 2 A h )

Constant power discharge/watts per battery to 1.67 vpc @ 25°C

D U R AT I O N

P r o d u c t s 5 min. 10 min. 1 5 m i n . 30 min. 60 min. 90 min. 5 hr. 8 hr. 10 hr. 20 hr.

G26VP 1 5 3 2 9 9 5 7 5 1 4 4 4 2 5 1 1 7 5 . 8 5 9 3 8 3 1 1 6( 2 6 A h )

G42VP 2 2 9 1 1 5 4 0 1 1 7 3 6 9 8 3 9 4 2 7 6 9 4 6 2 5 1 2 8( 4 2 A h )

LIFE EXPECTA N C YT E M P E R ATURE RANGE

Page 17: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS SELECTION GUIDE

15Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

GENESIS VP MECHANICAL SPECIFICATIONS (A,B,& C — M A X I M U M )

DIMENSIONS in. (mm)

We i g h tP r o d u c t s A B C D E lb. (kg)

G 2 6 V P 6 . 5 6 5 6 . 9 2 0 4 . 9 5 7 0 . 6 4 1 . 0 6 2 2 . 3( 1 6 6 . 7 5 ) ( 1 7 5 . 7 7 ) ( 1 2 5 . 9 1 ) ( 1 6 . 3 ) ( 2 7 . 0 ) ( 1 0 . 1 )

G 2 6 V P X 6 . 6 3 6 7 . 0 4 9 5 . 0 4 0 0 . 6 9 1 . 1 1 2 3 . 8( 1 6 8 . 5 5 ) ( 1 7 9 . 0 4 ) ( 1 2 8 . 0 2 ) ( 1 7 . 5 ) ( 2 8 . 2 ) ( 1 0 . 8 )

G 4 2 V P 7 . 7 7 5 6 . 5 2 5 6 . 7 1 5 0 . 7 4 0 . 8 7 3 2 . 9( 1 9 7 . 4 9 ) ( 1 6 5 . 7 4 ) ( 1 7 0 . 5 6 ) ( 1 8 . 8 ) ( 2 2 . 0 ) ( 1 4 . 9 )

G 4 2 V P X 7 . 8 6 6 6 . 6 5 9 6 . 8 0 3 0 . 7 9 0 . 9 1 3 5 . 1( 1 9 9 . 8 0 ) ( 1 6 9 . 1 4 ) ( 1 7 2 . 8 0 ) ( 2 0 . 1 ) ( 2 3 . 2 ) ( 1 5 . 9 )

Shown without metal jacket

Page 18: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS CONSTANT CURRENT (CC) DISCHARGE

GENESIS CONSTANT POWER (CP) DISCHARGE

GENESIS SELECTION GUIDE

16Certificate Number EMS 39520, ISO 14001 CertifiedCertificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

Page 19: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

GENESIS SELECTION GUIDE

17Certificate Number EMS 39520, ISO 14001 Certified

Certificate Number FM 32099, ISO 9001 CertifiedPublication No. US-GPL-SG-001 March 2003

ENERSYS STANDARD PRODUCT LISTGENESIS EP BAT T E R I E S

PA RT P E R F O R M A N C E M E C H A N I C A LN U M B E R D E S C R I P T I O N V O LTA G E 10 Hr RAT E S P E C I F I C AT I O N S S P E C I F I C AT I O N S0 7 7 0 - 2 0 0 7 G13EP (13Ah) 1 2 V 1 3 A h page 10 page 110 7 7 0 - 2 0 0 3 G13EPX (13Ah) 1 2 V 1 3 A h page 10 page 110 7 6 9 - 2 0 0 7 G16EP (16Ah) 1 2 V 1 6 A h page 10 page 110 7 6 9 - 2 0 0 3 G16EPX (16Ah) 1 2 V 1 6 A h page 10 page 110 7 6 5 - 2 0 0 1 G26EP (26Ah) 1 2 V 2 6 A h page 10 page 110 7 6 5 - 2 0 0 3 G26EPX (26Ah) 1 2 V 2 6 A h page 10 page 110 7 6 6 - 2 0 0 1 G42EP (42Ah) 1 2 V 4 2 A h page 10 page 110 7 6 6 - 2 0 0 3 G42EPX (42Ah) 1 2 V 4 2 A h page 10 page 110 7 7 1 - 2 0 0 1 G70EP (70Ah) 1 2 V 7 0 A h page 12 page 130 7 7 1 - 2 0 0 3 G70EPX (70Ah) 1 2 V 7 0 A h page 12 page 13

GENESIS VP BAT T E R I E S

PA RT P E R F O R M A N C E M E C H A N I C A LN U M B E R D E S C R I P T I O N V O LTA G E 10 Hr RAT E S P E C I F I C AT I O N S S P E C I F I C AT I O N S0 7 6 5 - 3 0 0 1 G26VP (26Ah) 1 2 V 2 6 A h page 14 page 150 7 6 5 - 3 0 0 3 G26VPX (26Ah) 1 2 V 2 6 A h page 14 page 150 7 6 6 - 3 0 0 1 G42VP (42Ah) 1 2 V 4 2 A h page 14 page 150 7 6 6 - 3 0 0 3 G42VPX (42Ah) 1 2 V 4 2 A h page 14 page 15

C A PACITY RATINGS BASED ON END OF DISCHARGE VOLTAGE OF 1.67 VOLTS/CELL AT 25°C

Page 20: GENESIS SELECTION GUIDE - logismarket.ind.br · Certificate Number EMS 39520, ISO 14001 Certified Certificate Number FM 32099, ISO 9001 Certified Publication No. US-GPL-SG-001 March

TM

TM

Global Headquar ter sP.O. Box 14145 Reading,PA 196212-4145USATel: +1-610-208-1991

+1-800-538-3627Fax: +1-610-372-8613

EnerSys EMEABrussels, BelgiumTel: +32 (0)2 247 94 47

EnerSys AsiaGuangdong, ChinaTel: +86-755-2689 3639www.enersysinc.com

Distributed by:

Publi

catio

n N

o.

US

-GP

L-S

G-0

01M

arch

200

3 - S

ubject to

revis

ion

with

out p

rior n