Genesis 32 wall hung condensing boiler MODELS OUTPUT (kW) H C 32.3

Transcript of Genesis 32 - uploads-ssl.webflow.com

Genesis 32wall hung condensing boiler

MODELS

OUTPUT(kW)

H

C

32.3

Nat Gas LPG 8:1

Modulation

Turndown

5yrHeat Exchanger

Warranty AEnergy Efficiency

Class

16.2Combi Flow

(l/m)

6NOx Class

*subject to Terms & Conditions

Genesis 32The Genesis 32 wall hung condensing boiler is available as a heating system boiler (H) or a combination boiler (C). The heart of the boiler has a highly durable stainless steel heat exchanger and offers an efficiency of 108% net. The Genesis 32 has a modulation range of 8:1, meaning it can turn down to 4.4kW for the lightest of application loads.

key featuresStainless steel heat exchanger

8:1 modulation ratio

Standard management of 2 heating zones

with ambient room temperature sensors

Combi DHW Flow of 16.2 (l/m)

Electronic control

Controls to manage two different types of

thermal solar systems fitted as standard

Weather compensation option

I N T R O D U C T I O N

MODEL

C

MODEL

H

5 year warranty* on heat exchanger2 year warranty* on parts

warranty

S I N G L E B O I L E R D I M E N S I O N S

SI

M

G

F

R

RS

C

condense drain

central heating flow (¾”)

gas inlet (½”)

cold water inlet (½”)

central heating return (¾”)

drain valve

dhw outlet (½”)

RC cold fill connection

MODEL

C

MODEL

H

technical data

Energy efficiency classNominal heat output (Pn) (kW)Seasonal energy efficiency of ambient heating (ηs) (%)Water heating energy efficiency (ηwh) (%)Nominal heat input (Qn) (kW)Nominal heat output (80-60°C) (Pn) (kW)Maximum boiler output (50-30°C) - NG & LPG (kW)Minimum boiler output (50-30°C) - NG & LPG (kW)Useful efficiency at nominal input (80-60°C) (%)Useful efficiency at 30% (30°C return) (%)Gas flow rate - NG (m3/h)Gas flow rate - LPG (kg/h)Heating circuit working pressure (min-max) (bar)CH temperature setting range (°C)Heating expansion vessel capacity (l)DHW circuit working pressure (min-max) (bar)Specific DHW flow ∆T=30K (l/min)DHW temperature range (°C)NOx emission class 6 (mg/kWh)Power supply voltage/frequency (V/Hz)Maximum power consumption (ErP) (W)Electric protection rating (IP)Gross weight (Kg)

32C 32H

MODEL

29

93

87 (**)

30.4

29.4

32.3

4.4

96.8

108.3

3.22

2.36

0.5-3.0

20-78

10

0.5-6.0

16.2

35-57

26

230/50

99

1PX5D

41.5

29

93

-

30.4

29.4

32.3

4.4

96.8

108.3

3.22

2.36

0.5-3.0

20-78

10

-

-

35-65(*)

26

230/50

99

1PX5D

38.5

A XXL A

*with cylinder probe connected **when comfort (keep warm) function is disabled

420

750

100

124 39

63 92 190

76 60 62 67 82 73

121

23

1031

R

MSI

C G F RC

RS

315

420

750

100

124 39

63 92 190

76 122 67 82 73

154

31

121

10

R

MSI

G F

RS

315

GENESIS H

GENESIS C

10

420

750

100

124 39

63 92 190

76 60 62 67 82 73

121

23

1031

R

MSI

C G F RC

RS

315

420

750

100

124 39

63 92 190

76 122 67 82 73

154

31

121

10

R

MSI

G F

RS

315

GENESIS H

GENESIS C

10

UN

DER

SID

E V

IEW

PLA

N V

IEW

UN

DER

SID

E V

IEW

PLA

N V

IEW

380

205

260

balance concentric flueswall terminal kit roof terminal kit

F L U E S Y S T E M S

The figures in the table are measured in metres and should be deducted from the maximum pipe length.concentric flue fittings

The balance flue wall terminal is Ø60/100. It is designed to terminate horizontally through an external wall, bringing in the combustion air from outside and exhausting the flue gases.

The balance flue roof terminal is Ø60/100. It is designed to terminate vertically through the roof, bringing in the combustion air from outside and exhausting the flue gases.

380

205

260

Balanced flue wall kit (length 75cm) including 90° elbow90° elbow M/F concentric45° elbow M/F concentricConcentric 1 metre length M/FConcentric 0.5 metre length M/FBalanced flue roof terminal kitAdjustable roof flashing (18-44° angle)

7

NOMINAL OUTPUT

CF-60/100WK

CF-60/100-90B

CF-60/100-45B

CF-60/100-1ML

CF-60/100-HML

CF-60/100RTK

CF-60/100ARF

1.5

0.5

0.5

1

0.5

1.5

0

MAXIMUM PIPE LENGTH (m)

32kW

CODE EQUIVALENT LENGTH (m)Ø60/100

205

260

205

260

174

120

For flue runs between 7m and 30m, Ø80/125 concentric flue can be utilised (contact sales office for details).

Modutherm Limited Unit 4 GenesisEndeavour Drive Basildon, SS14 3WF