Nat Gas LPG 8:1
Modulation
Turndown
5yrHeat Exchanger
Warranty AEnergy Efficiency
Class
16.2Combi Flow
(l/m)
6NOx Class
*subject to Terms & Conditions
Genesis 32The Genesis 32 wall hung condensing boiler is available as a heating system boiler (H) or a combination boiler (C). The heart of the boiler has a highly durable stainless steel heat exchanger and offers an efficiency of 108% net. The Genesis 32 has a modulation range of 8:1, meaning it can turn down to 4.4kW for the lightest of application loads.
key featuresStainless steel heat exchanger
8:1 modulation ratio
Standard management of 2 heating zones
with ambient room temperature sensors
Combi DHW Flow of 16.2 (l/m)
Electronic control
Controls to manage two different types of
thermal solar systems fitted as standard
Weather compensation option
I N T R O D U C T I O N
MODEL
C
MODEL
H
5 year warranty* on heat exchanger2 year warranty* on parts
warranty
S I N G L E B O I L E R D I M E N S I O N S
SI
M
G
F
R
RS
C
condense drain
central heating flow (¾”)
gas inlet (½”)
cold water inlet (½”)
central heating return (¾”)
drain valve
dhw outlet (½”)
RC cold fill connection
MODEL
C
MODEL
H
technical data
Energy efficiency classNominal heat output (Pn) (kW)Seasonal energy efficiency of ambient heating (ηs) (%)Water heating energy efficiency (ηwh) (%)Nominal heat input (Qn) (kW)Nominal heat output (80-60°C) (Pn) (kW)Maximum boiler output (50-30°C) - NG & LPG (kW)Minimum boiler output (50-30°C) - NG & LPG (kW)Useful efficiency at nominal input (80-60°C) (%)Useful efficiency at 30% (30°C return) (%)Gas flow rate - NG (m3/h)Gas flow rate - LPG (kg/h)Heating circuit working pressure (min-max) (bar)CH temperature setting range (°C)Heating expansion vessel capacity (l)DHW circuit working pressure (min-max) (bar)Specific DHW flow ∆T=30K (l/min)DHW temperature range (°C)NOx emission class 6 (mg/kWh)Power supply voltage/frequency (V/Hz)Maximum power consumption (ErP) (W)Electric protection rating (IP)Gross weight (Kg)
32C 32H
MODEL
29
93
87 (**)
30.4
29.4
32.3
4.4
96.8
108.3
3.22
2.36
0.5-3.0
20-78
10
0.5-6.0
16.2
35-57
26
230/50
99
1PX5D
41.5
29
93
-
30.4
29.4
32.3
4.4
96.8
108.3
3.22
2.36
0.5-3.0
20-78
10
-
-
35-65(*)
26
230/50
99
1PX5D
38.5
A XXL A
*with cylinder probe connected **when comfort (keep warm) function is disabled
420
750
100
124 39
63 92 190
76 60 62 67 82 73
121
23
1031
R
MSI
C G F RC
RS
315
420
750
100
124 39
63 92 190
76 122 67 82 73
154
31
121
10
R
MSI
G F
RS
315
GENESIS H
GENESIS C
10
420
750
100
124 39
63 92 190
76 60 62 67 82 73
121
23
1031
R
MSI
C G F RC
RS
315
420
750
100
124 39
63 92 190
76 122 67 82 73
154
31
121
10
R
MSI
G F
RS
315
GENESIS H
GENESIS C
10
UN
DER
SID
E V
IEW
PLA
N V
IEW
UN
DER
SID
E V
IEW
PLA
N V
IEW
380
205
260
balance concentric flueswall terminal kit roof terminal kit
F L U E S Y S T E M S
The figures in the table are measured in metres and should be deducted from the maximum pipe length.concentric flue fittings
The balance flue wall terminal is Ø60/100. It is designed to terminate horizontally through an external wall, bringing in the combustion air from outside and exhausting the flue gases.
The balance flue roof terminal is Ø60/100. It is designed to terminate vertically through the roof, bringing in the combustion air from outside and exhausting the flue gases.
380
205
260
Balanced flue wall kit (length 75cm) including 90° elbow90° elbow M/F concentric45° elbow M/F concentricConcentric 1 metre length M/FConcentric 0.5 metre length M/FBalanced flue roof terminal kitAdjustable roof flashing (18-44° angle)
7
NOMINAL OUTPUT
CF-60/100WK
CF-60/100-90B
CF-60/100-45B
CF-60/100-1ML
CF-60/100-HML
CF-60/100RTK
CF-60/100ARF
1.5
0.5
0.5
1
0.5
1.5
0
MAXIMUM PIPE LENGTH (m)
32kW
CODE EQUIVALENT LENGTH (m)Ø60/100
205
260
205
260
174
120
For flue runs between 7m and 30m, Ø80/125 concentric flue can be utilised (contact sales office for details).
Modutherm Limited Unit 4 GenesisEndeavour Drive Basildon, SS14 3WF
modutherm.co.ukTel: 0345 521 [email protected] member of the Modular Heating Group. CB/0120