General · PDF fileGENERAL CATALOGUE 2008 ÉEPCEN08-500&ËÍ Daikin’s...
Transcript of General · PDF fileGENERAL CATALOGUE 2008 ÉEPCEN08-500&ËÍ Daikin’s...
Naamloze Venootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW BE 0412 120 336
RPR Oostende
w w w . d a i k i n . e uw w w . d a i k i n . e u
h e a t i n g , a i r c o n d i t i o n i n g , a p p l i e d s y s t e m s , r e f r i g e r a t i o n
G E N E R A L C ATA L O G U E 2 0 0 8
ÉEPCEN08-500&ËÍ
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe N.V. participates in the Eurovent Certifi cation Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certifi ed data of certifi ed models are listed in the Eurovent Directory. Multi units are Eurovent certifi ed for combinations up to 2 indoor units. VRV products, Rooftops, FWB-J and FWD-units are not within the scope of the Eurovent Certifi cation Programme.
The present catalogue is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this catalogue to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fi tness for particular purpose of its content and the products and services presented therein. Specifi cations are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this catalogue. All content is copyrighted by Daikin Europe N.V..
Daikin products are distributed by:
EPCE
N08
-500
• 1
900
• 02
/200
8 •
Copy
right
© D
aiki
n Th
e pr
esen
t pu
blic
atio
n su
pers
edes
EPC
EN08
-500
_PPr
inte
d in
Bel
gium
by
Lann
oo (w
ww
.lann
oopr
int.
be),
a co
mpa
ny w
hose
con
cern
fo
r th
e en
viro
nmen
t is
set
in t
he E
MA
S an
d IS
O 1
4001
sys
tem
s.Re
spon
sibl
e ed
itor:
Dai
kin
Euro
pe N
.V.,
Zand
voor
dest
raat
300
, B-8
400
Oos
tend
e
Gen
eral
CA
TA
LO
GU
E 2
00
8
1
F o r e w o r d
THE LEADER IN MANUFACTURING QUALITY AND CUSTOMER SERVICESince our establishment in Ostend (Belgium) in 1972, we have updated and expanded our manufacturing facilities, including those opened more recently in Plzen and Brno (Czech Republic) and Cecchina (Italy) – through the acquisition of McQuay - to a point where they are now acknowledged as the most advanced in their fi eld in Europe. Furthermore, all our plants benefi t from our Japanese parent’s policy of zero defect production, super effi cient supply chain management and unrivalled research and development support.
These substantial production facilities are under pinned by a network of wholly owned affi liate companies in the UK, France, Germany, Italy, Spain, Portugal, Poland, Greece, Belgium, Holland and Central Europe, as well as numerous independent distributors throughout Europe, Africa and the Middle East supported by several head offi ces in Ireland, Russia, Turkey, South Africa and the Middle East. Experienced and professional support of this order enables us to maintain an enviably close relationship with international markets, tailor our product programme to suit precise regional requirements and respond quickly and effi ciently to any area of potential market expansion.
THE LEADER IN PRODUCT QUALITYDaikin produces a highly energy effi cient and comprehensive range of quality indoor climate control products and systems for commercial, residential and industrial applications. Our product portfolio is based on four distinct core ‘pillars’:- state of the art direct expansion air conditioning - heat pump residential and light commercial heating, domestic hot water and cooling - applied central cooling and heating - medium to low temperature refrigeration Each pillar harnesses advanced technologies to deliver maximum energy effi ciency and minimum fuel consumption and running costs throughout the equipment life cycle. The width of our product range is also extensive and embracing in its coverage of these key indoor climate control disciplines to a point where we are confi dent of its ability to meet the requirements of our end user, specifi er, contractor and installer customer base at all times.
RESPECT FOR THE ENVIRONMENTDaikin has an enviable record in concern for environmental issues and applies it to all areas of the business, implementing and in many cases pre-empting, international and local environmental protective legislation. We seek to operate a zero waste and zero emissions policy in our manufacturing plants. Our products refl ect the concept of combining maximising energy effi ciency with maximum respect for the environment. Their utilisation of heat pump technology for example, results in far lower energy consumption and in the case of heating, drastically less CO2 emissions than are achievable with fossil fuel burning systems. Also their incorporation of numerous detailed features such as inverter control, heat recovery, economy and quiet operating modes, movement sensors among others, enhance user comfort without compromise to either effi ciency or the environment. Thus, the products contained in this catalogue are designed to represent the best possible answer to your air conditioning needs. Feel free to contact your local Daikin representative for further information and assistance. We are here to serve you!
THE FUTURE LEADERDaikin’s position at the forefront of air conditioning manufacturing and marketing is well established and widely acknowledged. Nevertheless, over the last few years we widened our product portfolio in order to offer customers a more comprehensive choice of indoor climate control solutions for the home, in business and at play. The successful moves into heat pump heating for residential and commercial applications and medium to low temperature refrigeration for retail and wholesale food outlets are testament to this policy. But our search for innovative solutions is ongoing and there will certainly be many more successes to come. The common denominators however, will remain, as they are today, the provision of individual comfort allied to innovation, quality, energy effi ciency and environmental acceptability.
2
T a b l e o f C o n t e n t s
Daikin Europe N.V.
Foreword 1Table of contents 2Environmental awareness 4Energy labeling 6Photocatalytic air purifier 8
3
H e a t i n gAltherma 10
To consult the explanation of the pictogrammes,please refer to page 240 of this catalogue.
A i r C o n d i t i o n i n gResidential & Commercial 14Wall mounted units 17Flexi type units 36Floor standing units 39Concealed ceiling units 42Cassette units 674-Way blow ceiling suspended cassette 87Ceiling suspended units 91
Rooftops and Packaged Systems 102Concealed ceiling units 104Rooftops 108
Twin, Triple, Double Twin & Multi Application 110Twin, Triple, Double twin applications 112Multi model applications 130
VRV® 140VRV® 25 years 142 VRV®III air-cooled outdoor units 144VRV®III-S 149VRV®-WII water-cooled outdoor units 152Indoor units 154Selection programmes 169
Ventilation 170HRV - Heat reclaim ventilation 172Outdoor air processing unit 174Air handling applications 175
Control Systems 178Individual control systems 180Centralised control systems 181Network Solutions 182
A p p l i e d S y s t e m sChillers 188Fan coil units 224
R e f r i g e r a t i o nConveni-pack 234
4
Environmental Awareness
AIR CONDITIONING AND THE ENVIRONMENTAir conditioning systems provide a signifi cant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a signifi cant contribution to limiting the impact on the environment.A number of ‘We Care’ icons are highlighted in green throughout the catalogue to indicate product features that have an impact on reducing energy consumption: Fan only, Night set mode, Econo mode, Energy effi ciency, Movement sensor and Home leave operation
5
DAIKIN’S COMMITMENT TO THE ENVIRONMENTThe pioneering concern for the environment and natural resources is a part of the entire global Daikin operation at all levels: from product design, manufacturing processes, down to the responsibility each individual Daikin employee takes for the environment.
This commitment is refl ected in three areas: reducing waste in manufacturing and operations, recycling materials, and designing and producing energy-effi cient climate control equipment.
REDUCING WASTE IN MANUFACTURING AND BUSINESS OPERATIONSIn 1998, Daikin Europe N.V. became the fi rst air conditioning manufacturer in Europe to obtain ISO 14001 environmental certifi cation. In addition, since 2004, not only the manufacturing plants but Daikin sales companies as well have obtained ISO 14001 certifi cation, underlining Daikin’s commitment to the environment at all levels of our organisation.
These certifi ed environmental plans include the reduction of waste at all levels. Our environmental targets are high: Daikin Europe N.V. is committed to a zero waste policy whereby as much as possible of its by products can be reused, recycled or recovered as useful resources.
RECYCLING MATERIALSDaikin Europe N.V. is fi rmly committed to recycling materials in all areas of its operations. Wastewater is treated before being discharged into the city drainage system, with the recovered sludge being a useful ingredient in cement manufacturing. Other waste is also carefully sorted and recycled, supported by a continually evolving factory layout that encourages the optimum use of resources. In addition to recycling, we invest signifi cantly in returnable packaging. The same high demands are also imposed on our suppliers.
Eliminating waste and optimum recycling reduce raw material consumption and contribute to effi cient manufacturing and operating processes, meaning fewer burdens on the environment.
ENERGY EFFICIENT CLIMATE CONTROL EQUIPMENTDaikin’s commitment to being a leader in environmental developments has led to a string of innovations in climate control equipment:• Daikin’s use of inverter technology for example reduces start-up time by 33% and allows the compressor to consume
only the power it actually needs to meet the cooling/heating needs of the moment. • Linking the use of inverter technology to reluctance DC compressor motors has further improves effi ciency, allowing
Daikin units to obtain the highest effi ciency ratings in the market. • Daikin also produces computerised air conditioning monitoring and control systems designed to ensure maximum
energy effi ciency at all times, such as Daikin’s latest I-controller technology which offers customers refi ned and energy effi cient control of Daikin heat recovery air conditioning installations, including remote monitoring via the Internet.
This list of innovations could be expanded endlessly. More importantly, it clearly demonstrates that technological innovation and concern for the environment can go hand in hand. At Daikin, these environmental priorities form an integral part of our corporate culture and are refl ected in all of our products.
Choosing Daikin means you can be sure that the cooling systems you use are the safest possible for the environment.
6
AABB
CCDD
EEFF
GG
Energy Labeling
Energy labeling is part of a wider European Climate Change program that targets energy effi ciency as one method of reducing CO2 emissions in order to meet the targets of the Kyoto protocol. By this means the European Commission hopes that improved awareness will result in customers purchasing the most economical (ecological) answer to their needs.
WHAT?The energy label provides information on the energy consumption of the unit. Air conditioning units (with cooling capacity 12kW) are classifi ed in seven different categories (A to G), according to their energy consumption and color coded according to the category to which they belong. The most energy effi cient units will be included in the A category, indicated by a green arrow on the label – less effi cient units will belong in G class, indicated by a red arrow on the label. The end user can easily compare the effi ciency of equal types of units from different brands.
THE LABEL?WHAT IS MENTIONED ON THE LABEL?Logo and name of manufacturer; name of indoor and outdoor unit (*)
Energy effi ciency class of the unit in cooling mode:
A EER � 3.20
B 3.20 � EER � 3.00
C 3.00 � EER � 2.80
D 2.80 � EER � 2.60
E 2.60 � EER � 2.40
F 2.40 � EER � 2.20
G 2.20 � EER
EnergyManufacturerOutside unitInside unitMore effi cient
Less effi cientAnnual energy consumption,kWh in cooling mode(Actual consumption will depend on how the apliance is usedand climate)
Cooling output kWEnergy effi ciency ratioFull load (the higher the better)
Type Cooling only
Cooling + Heating Air cooled
Water cooledHeat output kW
Heating performanceA: higher G: lower
Noise(dB(A) re 1 pW)
Further information is containedin product brochures
Air-conditionerEnergy Label Directive 2002/31/EC
7
INDICATED ANNUAL ENERGY CONSUMPTIONThis fi gure indicates the approximate amount of energy consumed per year by the unit, based on a standard household model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year IN COOLING MODE AT FULL LOAD. In order to calculate the cost of annual energy consumption, you merely multiply this fi gure by your electricity tariff.
COOLING OUTPUTCooling output is defi ned as the cooling capacity in kW of the appliance, operating in cooling mode at full load. It is important to choose an air conditioning unit with a rated output suffi cient for your cooling/heating requirements. An oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer.
ENERGY EFFICIENCY RATIO (EER)This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input). In other words, the higher the EER, the greater the energy effi ciency.
TYPETYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating systemCOOLING MODE: it indicates if the unit is air cooled or water cooled
HEATING OUTPUTHeating output is defi ned as the heating capacity in kW of the appliance, operating in heating mode at full load.
ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE:
A EER � 3.60
B 3.60 � EER � 3.40
C 3.40 � EER � 3.20
D 3.20 � EER � 2.80
E 2.80 � EER � 2.60
F 2.60 � EER � 2.40
G 2.40 � EER
Noise level: only for portable units.
(*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units (wall mounted type) - for other units we refer to the multi brochure.
8
MC707VM-WMC707VM-S
Photocatalytic Air Purifier
PURE AIR FOR FREE AND HEALTHY BREATHING
• stylish design• improved performance• unprecedented comfort• super quiet operation• easy to maintain• portable• no installation
THREE TIMES PURIFICATION, A GOOD DEED FOR YOUR HEALTH
Pollen, dust and pet hair are just some of the potential causes of allergies, asthma and respiratory problems. A Daikin air purifi er cleans the air and relieves you of these troubles thanks to a three-part operation:
• allergen removal • virus and bacteria removal • odour removal
Pre-filter (with catechin) Removes large dust
particles and pet hairs.
Bio-antibody filterAirborne viruses are
captured and removed.
Plasma ionizerDust and pollen are
positively charged and sent to the electrostatic filter.
Dirty air
Daikin has already received great praise for its air purifi ers: a UK allergy certifi cate and the daikin TüV award confi rm the effi ciency of our units.
9
MC707VM-SMC707VM-W
Purified air
Flash Streamer High-speed electrons are generated by the Flash
Streamer. These electrons powerfully break down
odours and formaldehyde.
Electrostatic dust collection filter
Positively charged dust and pollen are adsorbed by the negatively charged filter.
Deodorising catalystOdours are adsorbed
and broken down before the air is
returned into the room.
Titanium Apatite Photocatalytic Filter
Odour, bacteria and viruses are adsorbed and decomposed.
Flash Streamer unit
Front
Back
MC707VM-W/S
Model MC707VM-W/SPower supply 1~, 220-240/220-230V, 50/60HzDimensions HxWxD mm 533x425x213Colour (W) = White + sparkling silver or (S) = Sparkling silver + metallic ocean blueWeight Kg 8.7
Mode (50Hz) Turbo H M L SilentPower input kW 0.055 0.023 0.014 0.010 0.008Sound pressure level dB(A) 47 38 31 24 16Sound power level dB(A) 62 52 40 39 31Air fl ow rate m3/h 420 285 180 120 60Dust collecting method Plasma ionizer (electrostatic dust collection) + Electrostatic dust collection fi lterDeodorising Method Flash Streamer + Titanium apatite photocatalytic fi lter + Deodorising catalyst
Deodorising performance (%) 95Regenerate method The Flash Streamer activates the photocatalytic reaction
Bacteria fi ltering method Bio-Antibody fi lter + Flash Streamer + Titanium apatite photocatalytic fi lterFilter Dust
collection and deodorisation
Form Pleated fi lterFunction Deodorisation + disinfection + dust collection + adjuvant removalLifetime 1 fi lter/1 year
Bio-Antibody fi lter NewPre-fi lter Catechin pre-fi lter
10
CHOOSING ALTHERMA ... NOTHING BUT BENEFITS!
LESS ENERGY, PLEASANT WARMTH IN THE HOME
Altherma heats up to 3 times more effi ciently than a traditional heating system based on fossil fuels or electricity. By making use of the heat in the outside air, you use much less energy, while still enjoying a stable, pleasant heat in your surroundings.On top, maintenance requirements are minimal, making your running cost low. Thanks to the inverter technology, your energy savings are even greater.
MINIMAL INSTALLATION COST
Altherma takes heat from the air. No digging or excavation works are required. Both the outdoor and indoor units are compact. The external unit can be located easily outside any building, including apartments. Without fl ames or fumes, there is no need for a chimney or constant ventilation in the room, where Altherma’s indoor unit is installed.
FLEXIBLE CONFIGURATIONS
Altherma can be confi gured for use in both new and refurbishment applications and connects to standard low temperature radiators, under fl oor heating or fan coil units. If you already have a heating system, you don’t need to change everything.
COMPLETE COMFORT FOR YOUR FAMILY
Altherma satisfi es your heating requirements but it can also supply your sanitary hot water and it comes with a cooling option for hot summer days.
ABSOLUTELY SAFE
Altherma doesn’t need oil, gas or other hazardous substances – naturally reducing a potential risk that goes together. Moreover, you don’t need a gas connection or a fuel tank. No risk of intoxication, smell or pollution from leaking tanks.
The intelligent way to comfort
11
INDOOR UNIT
EKHBH008AA*** EKHBX008AA*** EKHBH016AB*** EKHBX016AB***Function Heating only Reversible Heating only ReversibleDimensions HxWxD mm 922x502x361 922x502x361 922x502x361 922x502x361Leaving water temperature range
heating °C 15~50 15~55cooling °C - 5~22 - 5 - 22
Drain valve YesMaterial Epoxy polyester painted galvanized steelColour RAL 9010 (neutral white)
FACTORY MOUNTED HEATERPower supply Capacity steps
EKHBH(X)008AA3V3 / EKHBH(X)016AB3V3 1 ~/230V 1EKHBH(X)008AA6V3 / EKHBH(X)016AB6V3 1 ~/230V 2EKHBH(X)008AA6WN / EKHBH(X)016AB6WN 3 ~/400V 2EKHBH(X)008AA6T1 / EKHBH(X)016AB6T1 3 ~/230V 2EKHBH(X)008AA9WN / EKHBH(X)016AB9WN 3 ~/400V 2EKHBH(X)008AA9T1 / EKHBH(X)016AB9T1 3 ~/230V 2
OUTDOOR UNIT
ERHQ006AD ERHQ007AD ERHQ008AD ERHQ011AA ERHQ014AA ERHQ016AADimensions HxWxD mm 735x825x300 1,349x980x420Nominal capacity7 heating kW 5.75 6.64 8.43 11.2 14.0 16.0
cooling kW 7.20 8.16 8.37 13.9 17.3 17.8Nominal input heating kW 1.26 1.58 2.08 2.46 3.17 3.83
cooling kW 2.27 2.78 2.97 3.79 5.78 6.77COP 3.18 3.13 3.00 4.55 4.42 4.18EER 2.37 2.26 2.21 3.67 2.99 2.63Operation range heating °C -20 ~ 25 -20 ~ 35
cooling °C 10 ~43 10 ~43domestic mode °C -20 ~ 43 -20 ~ 43
Sound pressure level
heating dBA 61 61 62 64 64 66cooling dBA 63 63 63 64 66 69
Weight kg 56 103Refrigerant charge R-410A kg 1.7 3.7Power supply 1 ~ /230V/50Hz 1 ~ /230V/50HzRecommended fuses A 20 32
Measuring conditions EKHBH(X)008AA: Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT=5°C) - Cooling Ta 35°C - LWE18°C (DT=5°C)Measuring conditions EKHBH(X)016AB: Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT=5°C) - Cooling Ta 35°C - LWE18°C (DT=5°C)
DOMESTIC HOT WATER TANK
EKHWS150A3V3 EKHWS200A3V3 EKHWS300A3V3 EKHWS2003Z2 EKHWS200A3Z2Water volume l 150 200 300 200 300Max. water temperature °C 85Height mm 900 1,150 1,600 1,150 1,600Diameter mm 580Booster heater kW 3Power supply 1 ~ /230V/50Hz 2 ~ /400V/50HzMaterial inside tank Stainless steel (DIN 1.4521)Material outside casing Epoxy-coated mild steelColour Neutral whiteEmpty weight kg 37 45 59 45 59
SOLAR KIT
EKSOLHWAV1Dimensions HxWxD mm 770x305x207Heat exchanger pressure drop kPA 21.5
Max. inlet temp °C 110heat ex. capacity W/K 1,400
Ambient temperature
max. °C 35min. °C 1
Power supply 1~/220-240V/50HzPower supply intake indoor unit
12
The solution for your total comfort
Altherma is a split system consisting of an outdoor unit and an indoor hydro-box that can be connected to all standard low temperature radiators and underfl oor heating systems.
OUTDOOR UNIT
An effi cient use of energy from the airAltherma uses a natural, renewable source of energy.The outdoor unit derives heat from the surrounding air and raises its temperature until it is high enough to heat a home. This heat is then transmitted to the indoor unit through refrigerant pipes. An advantage of this is that the pipes can never freeze. The compact outdoor unit is easily installed and can also be used in residences without a garden.
INDOOR UNIT
The heart of the altherma systemThe indoor unit heats the water that circulates through your low temperature radiators, fl oor heating systems or fan coil units and provides you with domestic hot water. If you opt for the combination of heating and cooling, then the indoor unit can also decrease the water temperature to distribute a refreshing coolness.
Did you know that...
The altherma system can be perfectly combined with solar collectors to produce hot water. The sun provides 30 to 70% of the energy required for our hot water needs. Altherma, your total solution, thinks of the future.
?
Outdoor unit
Indoor unit
Domestic hot water tank
13
DOMESTIC HOT WATER TANK
For low energy cosumptionAs for your domestic hot water, Altherma is just as clever. The unique lay-out and special placement of different elements maximise energy effi ciency. The water inside the storage tank is primarily warmed up by thermal energy from the outside air, thanks to a heat exchanger connected to the heat pump. However, an additional electrical heating element in the domestic water tank can take care of extra heat you need in your shower, bath or sink. At necessary intervals the water is automatically heated to 70°C in order to stay clear of bacteria. With Altherma you can enjoy delightfully warm and perfectly safe water at all times. Depending on the daily consumption of hot water, Altherma domestic hot water tanks come
in three different sizes, with the largest one being the most effi cient.
INTELLIGENT TEMPERATURE REGULATOR
The operation of the system is integrated in the indoor unit. With Altherma, it is possible to regulate your heating and (optional) cooling system according to your needs. Your installer can set up a full weekly programme for you, per hour or per day. In this way, the temperature is reduced automatically at night or during your holiday, and it is once again pleasantly warm when you get up or return home. The fl oating setpoint, is a built-in variable thermostat that adjusts the water temperature to the outdoor temperature.By keeping the water temperature at the lowest possible level, maximum effi ciency of the system is achieved. The system can be combined with additional temperature regulating systems with separate thermostats for living rooms, bedrooms, and so forth.
Fan coil unit
Low temperature radiator
Domestic hot water
Under fl oor heating
14
15
1. Wall mounted units
2. Flexi type units
3. Floor standing units
4. Concealed ceiling units
5. Cassette units
6. 4-Way blow ceiling suspended cassettes
7. Ceiling suspended units
Daikin residential air conditioning is the modern, economic and effi cient way to switch on to springtime - in the living room, dining room, kitchen or bedroom, night and day, throughout the year.Daikin air conditioning units are easy to install, easy to use, ultra reliable, quiet running and come in an elegant and up to date range of wall, fl oor and ceiling mounted indoor models. Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the residential market today. Inverter control cuts start up time and energy consumption by almost a third, alters unit output to suit outdoor conditions, improves performance relative to power input, ensures a more even room temperature and eliminates power surges and stop/start cycles.
Residential & CommercialFTXR-E / RXR-E 17FTXG-E / RXG-E 19FTXS-G / RXS-G 21FTX-GV / RX-GV 22FTXS-F / RXS-F 23FTYN-GX / RYN-GX 24FTYN-F / RYN-E 25FAQ-B / RQ-B 26FAQ-B / RZQS-C 27FAQ-B / RZQ-C 28FAQ-B / RZQ-B 29FTXS-G / RKS-G 30FTK-GV / RK-GV 31FTKS-F / RKS-F 32FTN-F / RN-E 33FAQ-B / RR-B 34
FLXS-B / RXS-G 36FLKS-B / RKS-G 37FLKS-B / RN-E 38
FVXS-F / RXS-G 39FVXS-F / RKS-G 40FVQ-B / RZQS-C 41
FDXS-E / RXS-G 42FDXS-C / RXS-G 43FDXS-C / RXS-F 44FBQ-B / RXS-G 46FBQ-B / RXS-F 47FBQ-B / RQ-B 48FBQ-B / REQ-B 49FBQ-B / RZQS-C 50FBQ-B / RZQ-C 51FBQ-B / RZQ-B 52FDQ-B / RQ-B 53FDQ-B / RZQS-C 54FDQ-B / RZQ-C 55FDQ-B / RZQ-B 56FDEQ-B / REQ-B 58FDKS-E / RKS-G 59FDKS-C / RKS-G 60FDKS-C / RKS-F 61FBQ-B / RKS-G 62FBQ-B / RKS-F 63FBQ-B / RN-E 64FBQ-B / RR-B 65FDQ-B / RR-B 66
FCQ-C / RXS-G 67FCQ-C / RXS-F 68FCQ-C / RQ-B 69FCQ-C / REQ-B 70FCQ-C / RZQS-C 71FCQ-C / RZQ-C 72FCQ-C / RZQ-B 73FCQH-C / RZQS-C 75FCQH-C / RZQ-C 76FCQH-C / RZQ-B 77FFQ-B / RXS-G 78FFQ-B / RXS-F 79FCQ-C / RKS-G 80FCQ-C / RKS-F 81FCQ-C / RN-E 82FCQ-C / RR-B 83FFQ-B / RKS-G 84FFQ-B / RKS-F 85FFQ-B / RN-E 86
FUQ-B / RQ-B 87FUQ-B / RZQ-C 88FUQ-B / RZQ-B 89FUQ-B / RR-B 90
FHQ-B / RXS-G 91FHQ-B / RXS-F 92FHQ-B / RQ-B 93FHQ-B / REQ-B 94FHQ-B / RZQS-C 95FHQ-B / RZQ-C 96FHQ-B / RZQ-B 97FHQ-B / RKS-G 98FHQ-B / RKS-F 99FHQ-B / RN-E 100FHQ-B / RR-B 101
newnew
new
new
new
new
Good Design Award
16
URURU SARARAA unique combination of humidifi cation, dehumidifi cation, ventilation and air purifi cation
Good temperature control is not all that is needed for a comfortable indoor climate. Precision control of humidity and ventilation of the room is essential. Thanks to the URURU SARARA, you can humidify, dehumidify, ventilate and purify. The unit is fi tted with fi lters that also fi lter dust, pollen and smoke. You can also adjust the air purifi cation to meet your specifi c needs. Thanks to the ventilation system, contaminated indoor air in a space is replaced with fresh outdoor air.
URURU humidifi cation: Pleasant, even during heating
The URURU humidifi cation system absorbs moisture from the outdoor air and transports it to the indoor unit, quickly and effi ciently humidifying the room. Thanks to the perfect combination of humidifi cation and air conditioning, your room heats evenly.
SARARA dehumidifi cation: Feel the difference!
When humidity is too high, the SARARA dehumidication system ensures that it is lowered without changing the room temperature. That is ideal for you, because lower humidity means you feel more comfortable.
• The ideal humidity• Comfortable air fl ow• Powerful air purifi cation• Stylish design (good design award)• Energy saving and high effi ciency: one unit of energy is
converted into more than fi ve units of energy for cooling or heating
Wall Mounted Unit
URURU humidifi cation: maintains a comfortable humidity level without any separate water supply
SARARA dehumidifi cation: maintains a comfortable and fresh indoor environment by removing moisture from the air without lowering the temperature
Energy effi cient: full range A class labels (EER = 5.00/COP = 5.14)
Powerful ventilation: refreshes the room within 2 hours
Powerful air purifi cation: increases indoor air quality with Daikin Flash Streamer technology
Comfortable air fl ow Stylish design Other features: moisturizing operation mode,
breeze cooling air fl ow, comfort sleep operation, mould shock operation
HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXR28EV1B9 FTXR42EV1B9 FTXR50EV1B9Capacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBA
Heating Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXR28EV1B9 RXR42EV1B9 RXR50EV1B9Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
5 steps
Titanium apatite photocatalytic air purifi cation fi lter
optional
1.55
2.8 4.2 5.0
3.6 4.60 5.50
1.30
3.6 5.1 6.0
5.00 5.6 6.20
5.00 / 5.14 4.00 / 4.32 3.42 / 3.97
280 525 730
A / A
209x890x30514
11.1 / 8.8 / 6.5 / 5.7 12.4 / 9.6 / 6.8 / 6.0 13.3 / 10.3 / 7.3 / 6.512.4 / 9.8 / 7.3 / 6.5 12.9 / 10.2 / 7.7 / 6.8 14.0 / 11.1 / 8.3 / 7.3
55 58 6057 58 60
39 / 33 / 26 / 23 42 / 35 / 27 / 24 44 / 37 / 29 / 2641 / 35 / 28 / 25 42 / 36 / 29 / 26 44 / 38 / 31 / 28
R-410A1~/220-240V/50Hz
693x795x28548
-10~43-20~18
60 6246 4846 48 50
R-410A1~/220-240V/50Hz
6.35 / 9.52 / 1810
FTXR-E / RXR-E
17
RXR28,42,50EFTXR28,42,50EARC447A
Good Design Award
FTK(X)S FTXG
18
STYLISH AND COMPACT DESIGN
Daikin succeeded in creating an indoor unit with such a sleek profi le, that you won’t believe it is an air conditioning unit.In standby mode, the discharge opening is closed, resulting in a compact depth of only 15cm.When starting the unit up, the entire front panel slides smoothly open.
For this model, Daikin even received the “Good Design Award” in Japan.
SENSATIONAL THINNING TECHNOLOGY
• High effi ciency slit fi n heat exchanger
• Miniature cross fl ow fan
The blade confi guration has been optimized to achieve quiet operation and powerful air fl ow, while reducing the fan’s diameter by 20% compared to conventional models.
SUPERB ENERGY EFFICIENCY
Daikin has further improved the energy effi ciency. At the same time it realized substantial energy savings compared to conventional models by achieving an industrial top class EER of 4.03 and COP of 4.15.These top of the class values are achieved by the following 3 technologies:
• PAM Inverter control• Reluctance DC motor + DC Fan motor• Swing compressor
CLEAN AND COMFORTABLE AIR FLOW
For the fi st time in history, a titanium apatite photocatalytic air purifi cation fi lter is integrated in an air conitioning unit. This to increase the active surface area for effective purifi cation and deodorisation, even when a high volume of air is required.
Super quiet:The indoor/outdoor unit silent operation function brings us comfort by offering an industry top-level quiet operation of 22dB(A) for the indoor unit and 43dB(A) for the outdoor unit.
COMFORT MODE
The new wide-angle distribution fl ap reassures draught free operation. During cooling operation the fl ap angle turns horizontally to prevent cold air blowing directly on the body, while during heating operation it turns downward vertically to send the warm air directly to the feet.
3-D AIR FLOW
This function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm air right to the corners of even large spaces.
25% size reduction Cooling mode Heating mode
Designed for people who do not only care for quality but also
care for stylish design
Wall Mounted Unit
State of the art design: sleek, compact and stylish outlook
Available in 2 colour variations: mat crystal white and mat crystal silver
Lightweight and compact Easy to clean fl at suction grille Superb energy effi ciency Movement sensor saves power consumption in
unoccupied rooms Comfort mode reassures draught free operation
thanks to the new wide angle distribution fl ap The new titanium apatite photocatalytic air
purifi cation fi lter increases the active surface area for effective purifi cation and deodorisation
Horizontal and vertical auto-swing 3D-air fl ow ensure effi cient air and temperature distribution.
Powerful mode can be selected for rapid cooling or heating
Indoor / outdoor unit silent operation
HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BSCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXG25E2V1B RXG35E2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
(5 steps) (standard)
(integrated titanium apatite)
(optional)
1.3 1.4
2.5 3.5
3.0 3.8
1.3 1.4
3.4 4.2
4.5 5.0
4.03 / 4.15 3.30 / 3.72
310 530
A / A
275x840x1509.0
7.7 / 6.1 / 4.7 / 3.8 8.1 / 6.5 / 4.9 / 4.19.0 / 7.9 / 6.7 / 5.4 9.6 / 8.2 / 6.7 / 5.9
56.0 57.056.0 57.0
38.0 / 32.0 / 25.0 / 22.0 39.0 / 33.0 / 26.0 / 23.038.0 / 33.0 / 28.0 / 25.0 39.0 / 34.0 / 29.0 / 29.0
R-410A1~/220-240V/50Hz
550x765x28532
10.0~46.0-15.0~20.0 -15~20
61.0 62.046.0 47.047.0 48.0
R-410A1~/230V/50Hz6.35 / 9.52 / 18
2015.0
FTXG-E / RXG-E
19
RXG25,35E FTXG25,35E_S FTXG25,35E_WARC433A41
MXS
20
ARC452A3
SPECIAL FEATURES
2 area intelligent eye
With this function, the air fl ow is sent to a zone other than where the person is located at that moment.If two people are detected in the room, the movement sensor, together with the comfort mode (cooling directed at the ceiling, heating directed at the fl oor), will see to it that the air fl ow is projected away from the occupants. If no people are detected, the unit will automatically switch over to the energy-effi cient setting.
Remote control
The new infrared remote control has a very stylish design, is user-friendly and equipped with a weekly timer. With this timer, you can programme a 7-day schedule with 4 different actions per day.Furthermore, the convenient copy function allows you to very quickly copy any day’s programme to one or more other days. Should there be a malfunction in the air conditioner, you can read the code on the LCD screen of the remote control and easily fi nd the appropriate solution.
Energy saving during operation standby
Once the standby current-saving function has been activated, the current consumption when operating on standby will be reduced by about 80%. If no people are detected for an extended period of time, i.e. more than 20 minutes, the system will automatically switch to the current-saving mode.
High tech on the inside,Att ractive design on the outside
Wall Mounted Unit
2 area intelligent eye: air fl ow is sent to the area in a room where no person is detected
Energy saving during stand by mode: reduction of energy from 10W to 2W
Weekly timer: allows to program the unit on a weekly basis
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Comfort mode reassures draught free operation 3D air fl ow Dual air discharge fl ow for better air distribution Consumes up to 30% less energy than non-
inverter units ECONO mode decreases power consumption
so that other appliances that need large power supply can be used
Indoor / outdoor unit silent operation Powerful mode can be selected for rapid cooling
or heating Reaches set temperature more quickly Titanium apatite photocatalytic air purifi cation fi lter
absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses
HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Capacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/min
Heating High m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS20G2V1B RXS25G2V1B RXS35G2V1B RXS42G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps
standard
(integrated titanium apatite)
1.3 1.3 1.4 1.7 1.7
2.0 2.5 3.5 4.2 5.0
2.8 3.2 4.0 5.0 5.3
1.3 1.3 1.4 1.7 1.7
2.7 3.4 4.0 5.4 5.8
4.3 4.7 5.2 6.0 6.5
4.26 / 4.29 4.55 / 4.53 4.02 / 4.17 3.44 / 3.67 3.29 / 3.69
235 275 435 610 760
A / A A / A A / A A / A A / A
295x800x215 295x800x215 295x800x215 295x800x215 295x800x2159 9 10 10 10
9.0 9.0 10.1 9.8 10.29.3 9.6 10.5 10.1 10.954 54 57 58 5954 55 57 58 60
38 / 32 / 25 / 22 38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 3138 / 33 / 28 / 25 39 / 34 / 28 / 25 42 / 36 / 29 / 26 42 / 38 / 33 / 30 44 / 39 / 34 / 31
R-410A R-410A R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
550x765x285 550x765x285 550x765x285 550x765x285 735x825x30034 34 34 39 48
-10~46 -10~46 -10~46 -10~46 -10~46-15~20 -15~20 -15~20 -15~20 -15~18
61 61 63 63 6243 43 44 44 4444 44 45 45 4546 46 48 48 4847 47 48 48 48
R-410A R-410A R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 20 20 30
FTXS-G / RXS-G
21
RXS20,25,35,42GFTXS20,25,35,42,50GARC452A3
Wall Mounted Unit
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Lightweight and compact Consumes up to 30% less energy than non-
inverter units Dual air discharge fl ow for better air distribution ECONO mode decreases power consumption
so that other appliances that need large power supply can be used
Indoor unit On/Off switch Indoor unit silent operation Titanium apatite photocatalytic air purifi cation fi lter Anticorrosion treatment of outdoor heat
exchanger fi n Powerful mode can be selected for rapid cooling
or heating Energy saving during stand by mode: reduction of
energy from 10W to 2W
HEAT PUMP INVERTERIndoor UnitsIndoor Units FTX20GV1B FTX25GV1B FTX35GV1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RX20GV1B RX25GV1B RX35GV1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
1.3
2.0 2.5 3.2
2.6 3.0 3.8
1.3
2.5 2.8 3.4
3.5 4.0 4.8
3.62 / 3.90 3.38 / 3.68 3.37 / 3.74
275 370 470
A / A
283x770x1987
9.1 / 7.4 / 5.9 / 4.7 9.2 / 7.6 / 6.0 / 4.8 9.3 / 7.7 / 6.1 / 4.99.4 / 7.8 / 6.3 / 5.5 9.7 / 8.0 / 6.3 / 5.5 10.1 / 8.4 / 6.7 / 5.7
55 56 5755 56 57
39 / 33 / 25 / 22 40 / 33 / 26 / 22 41 / 34 / 27 / 2339 / 34 / 28 / 25 40 / 34 / 28 / 25 41 / 35 / 29 / 26
R-410A1~/220-230-240V/50Hz
550x658x27528 30
10~46-15~20
60 6246 4847 48
R-410A1~/220-230-240V/50Hz
6.35 / 9.52 / 1815
FTX-GV / RX-GV
22
RX20,25,35GVFTX20,25,35GVARC433A87
Wall Mounted Unit
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Lightweight and compact Home leave operation saves energy during
absence Movement sensor saves power consumption in
unoccupied rooms Dual air discharge fl ow for better air distribution Titanium apatite photocatalytic air purifi cation fi lter Indoor / outdoor unit silent operation
HEAT PUMP INVERTERIndoor UnitsIndoor Units FTXS60FV1B FTXS71FV1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBA
Heating Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS60F2V1B RXS71FV1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps
standard MXS
1,7 2,3
6,0 7,1
6,7 8,5
1,7 2,3
7,0 8,2
8,0 10,2
3,02 / 3,43 3,02 / 3,22
995 1175
B / B B / C
290x1050x23812
16,2 / 13,6 / 11,4 / 10,2 17,4 / 14,6 / 11,6 / 10,617,4 / 15,1 / 12,7 / 11,4 19,7 / 16,9 / 14,3 / 12,7
61 6260 62
45 / 41 / 36 / 33 46 / 42 / 37 / 3444 / 40 / 35 / 32 46 / 42 / 37 / 34
R-410A1~/220-240V/50Hz
735x825x300 770x900x32048 71
-10~46-15~18
63 6649 5249 5246 49
R-410A1~/220-240/220-230V/50Hz
6,35 / 12,7 / 18 6,35 / 15,9 / 1830
FTXS-F / RXS-F
23
RXS60,71FFTXS60,71FARC433A70
Wall Mounted Unit
Fits neatly on a wall Wide angle louvers provide a comfortable air fl ow
throughout the entire room 24-Hour On/Off timer Indoor unit On/Off switch Power-airfl ow fl ap Anti-corrosion treated plate type heat exchangers
HEAT PUMP NON-INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low dBA
Heating High/Medium/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD) /Gas / Drain mmPiping Length (Maximum) m
optional
3 steps standard
FTYN25GXV1B FTYN35GXV1B2.5 3.21
2.85 3.583.25 / 3.65 3.21 / 3.61
385 500
A / A A / A
288 x 800 x 204 288 x 800 x 2049 9
9.5 9.8- -- -
38 / 32 / 27 38 / 24 / 2938 / 33 / 27 40 / 35 / 29
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
RYN25GXV1B RYN35GXV1B550 x 765 x 285 550 x 765 x 285
31 34 10~46 10~46-10~24 -10~24
- -48 4949 50
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 12.7 / 1815 15
FTYN-GX / RYN-GX
24
RYN25,35GXARC461A3 FTYN25,35GX
Wall Mounted Unit
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Lightweight and compact Titanium apatite photocatalytic air purifi cation fi lter Powerful mode can be selected for rapid cooling
or heating Auto-swing function ensures effi cient air and
temperature distribution.
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FTYN50FV1B FTYN60FV1BNominal Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/min
Heating High/Medium/Low m³/minSound Power Cooling Medium dBA
Heating Medium dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RYN50E3V1B RYN60E3V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional 5 steps
standard 50 + 60 class
5.0 6.0
5.8 7.0
3.23 / 3.63 3.02 / 3.43
775 995
A / A B / B
290x1050x23812
14.7 / 12.4 / 10.3 16.2 / 13.6 / 11.416.1 / 13.9 / 11.5 17.4 / 15.1 / 12.7
59 6158 60
43 / 34 45 / 3642 / 33 44 / 35
R-410A1~/220-240V/50Hz
735x825x30048
-10.0~46.0-15~18
61.0 63.047.0 49.048.0 49.0
R-410A1~/220-240V/50Hz
6.35 / 12.7 / 1830
20.0
FTYN-F / RYN-E
25
RYN50,60EFTYN50,60FARC433A72
Wall Mounted Unit
Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off
Automatic movable louver can be fi xed at any desired angle
Both horizontal fl aps and front panel can easily be removed and washed
All maintenance operations can be carried out from the front of the unit
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps
optional optional
heat pump optional
7.1 7.1 10.0 10.0
8.0 8.0 11.2 11.2
2.68 / 3.10 2.81 / 3.21 2.81 / 2.83 2.84 / 2.93
1325 1265 1780 1760
D / D C / C C / D C / D
290x1050x230 360x1570x20013.0 26.0
19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32084 83 103 101
-5.0~46.0-10.0~15.0
63.0 66.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FAQ-B / RQ-B
26
RQ100BFAQ71B BRC1D52 BRC7E618/C510
Wall Mounted Unit
Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off
Automatic movable louver can be fi xed at any desired angle
Both horizontal fl aps and front panel can easily be removed and washed
All maintenance operations can be carried out from the front of the unit
HEAT PUMP INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps optional
optional
optionalheat pump
7.1 10.0
8.0 11.2
2.81 / 3.07 2.45 / 3.00
1,265 2,040
C / D E / D
290x1050x230 360x1570x20013.0 26.0
19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0
R-410A220-240V/50Hz
770x900x320 700x900x32068
-5~46-15~15.5
65 6749 5151 5547 49
R-410A220-240V/50Hz9.52 / 15.9 / 26
30 500.5
FAQ-B / RZQS-C
27
RZQS71,100CFAQ71B BRC1D52 BRC7E618/510
Wall Mounted Unit
Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off
Automatic movable louver can be fi xed at any desired angle
Both horizontal fl aps and front panel can easily be removed and washed
All maintenance operations can be carried out from the front of the unit
HEAT PUMP INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional
2 steps optional
optional
optional
7.1 10
8.0 11.2
3.01 / 3.31 2.9 / 3.43
1,180 1725
B / C C / B
290x1050x230 360x1570x20013.0 26.0
19.0 / 15.0 23.0 / 19.019.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.043.0 / 37.0 45.0 / 41.0
R-410A220-240V/50Hz
770x900x320 1170x900x32067 103
-15.0~50.0-20.0~15.5
63 6547 4949 5143 45
R-410A220-240V/50Hz9.52 / 15.9 / 26
50 750.5
FAQ-B / RZQ-C
28
FAQ71B BRC1D52 BRC7E618 RZQ71C
Wall Mounted Unit
Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off
Automatic movable louver can be fi xed at any desired angle
Both horizontal fl aps and front panel can easily be removed and washed
All maintenance operations can be carried out from the front of the unit
HEAT PUMP INVERTERIndoor UnitsIndoor Units FAQ100BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ100B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional
2 steps optional
optional
optional
10.00
11.20
3.60 / 3.30
1390
A / C
360x1570x20026.0
23.0 / 19.023.0 / 19.061.0 / 57.061.0 / 57.045.0 / 41.045.0 / 41.0
R-410A220-240V/50Hz
1345x900x320106
-15.0~50.0-20.0~15.5
65.049.051.045.0
R-410A400V/50Hz
9.52 / 15.9 / 26750.5
FAQ-B / RZQ-BW1
29
RZQ100BFAQ71B BRC1D52 BRC7E618/C510
Wall Mounted Unit
2 area intelligent eye: air fl ow is sent to the area in a room where no person is detected
Energy saving during stand by mode: reduction of energy from 10W to 2W
Weekly timer: allows to program the unit on a weekly basis
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Comfort mode reassures draught free operation 3D air fl ow Dual air discharge fl ow for better air distribution Consumes up to 30% less energy than non-
inverter units ECONO mode decreases power consumption
so that other appliances that need large power supply can be used
Indoor / outdoor unit silent operation Powerful mode can be selected for rapid cooling
or heating Reaches set temperature more quickly Titanium apatite photocatalytic air purifi cation fi lter
absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses
COOLING ONLY INVERTERIndoor UnitsIndoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Capacity Cooling capacity Minimum kW
Standard kW
Maximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS20G2V1B RKS25G2V1B RKS35G2V1B RKS42G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps
standard
(integrated titanium apatite)
1.3 1.3 1.4 1.7 1.7
2.0 2.5 3.5 4.2 5.0
2.8 3.2 4.0 5.0 5.3
4.26 4.55 4.02 3.44 3.29
235 275 435 610 760
A A A A A
295x800x215 295x800x215 295x800x215 295x800x215 295x800x2159 9 10 10 10
9.0 9.0 10.1 9.8 10.254 54 57 58 5954 55 57 58 60
38 / 32 / 25 / 22 38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 31R-410A R-410A R-410A R-410A R-410A
1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
550x765x285 550x765x285 550x765x285 550x765x285 735x825x30034 34 34 39 48
-10~46 -10~46 -10~46 -10~46 -10~4661 61 62 61 6143 43 44 44 4446 46 48 48 48
R-410A R-410A R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 1820 20 20 20 30
FTXS-G / RKS-G
30
FTXS20,25,35,42,50GARC452A3 RKS20,25,35,42G
Wall Mounted Unit
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Lightweight and compact Consumes up to 30% less energy than non-
inverter units Dual air discharge fl ow for better air distribution ECONO mode decreases power consumption
so that other appliances that need large power supply can be used
Indoor unit On/Off switch Indoor unit silent operation Powerful mode can be selected for rapid cooling Titanium apatite photocatalytic air purifi cation fi lter Anticorrosion treatment of outdoor heat
exchanger fi n Energy saving during stand by mode: reduction of
energy from 10W to 2W
COOLING ONLY INVERTERIndoor UnitsIndoor Units FTK20GV1B FTK25GV1B FTK35GV1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RK20GV1B RK25GV1B RK35GV1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
1.3
2.0 2.5 3.2
2.6 3.0 3.8
3.62 3.38 3.37
275 370 475
A
283x770x1987
9.1 / 7.4 / 5.9 / 4.7 9.2 / 7.6 / 6.0 / 4.8 9.3 / 7.7 / 6.1 / 4.955 56 57
39 / 33 / 25 / 22 40 / 33 / 26 / 22 41 / 34 / 27 / 23R-410A
1~/220-230-240V/50Hz
550x658x27528 30
10~4660 6246 48
R-410A1~/220-230-240V/50Hz
6.35 / 9.52 / 1815
FTK-GV / RK-GV
31
RK20,25,35GVFTK20,25,35GVARC433A87
Wall Mounted Unit
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean.
Lightweight and compact Home leave operation saves energy during
absence Movement sensor saves power consumption in
unoccupied rooms Dual air discharge fl ow for better air distribution Titanium apatite photocatalytic air purifi cation fi lter Indoor / outdoor unit silent operation
COOLING ONLY INVERTERIndoor UnitsIndoor Units FTKS60FV1B FTKS71FV1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling Medium dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS60FV1B RKS71FV1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
5 steps
standard optional MKS
1.7 2.3
6.0 7.16.7 8.5
3.02 3.02
995 1175B B
290x1050x238 290x1050x23812 12
16.2 / 13.6 / 11.4 / 10.2 17.4 / 14.6 / 11.6 / 10.661 62
45 / 41 / 36 / 33 46 / 42 / 37 / 34R-410A R-410A
1- / 220-240V / 50Hz 1- / 220-240V / 50Hz
735x825x300 770x900x32047 71
49 / 46 52 / 4663 66
-10-46 -10-46R-410A R-410A
1-/220-240V/50Hz 1-/220-240V/50Hz6.35 / 12.7 / 18 6.35 / 15.9 / 18
30 3020 20
FTKS-F / RKS-F
32
RKS60,71FFTKS60,71FARC433A70
Wall Mounted Unit
Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean,
Lightweight and compact Titanium apatite photocatalytic air purifi cation fi lter Powerful mode can be selected for rapid cooling Auto-swing function ensures effi cient air and
temperature distribution,
COOLING ONLY NON-INVERTERIndoor UnitsIndoor UnitsNominal Capacity Cooling capacity Standard kW
MinimumMaximum
EER Nominal
Annual energy consumption kWh
Energy Label Cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low m³/minSound Power Cooling Medium dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional 5 steps
standard 50 + 60 class
FTN50FV1B FTN60FV1B5.0 6.0
- -- -
3.23 3.02
775 995
A B
290x1050x238 290x1050x23812 12
14.7 / 12.4 / 10.3 16.2 / 13.6 / 11.459 61
43 / 34 45 / 36R-410A R-410A
1~/220-240V/50Hz 1~/220-240V/50Hz
RN50E3V1B RN60E3V1B735x825x300 735x825x300
47 4747 4961 63
-10.0~46.0 -10.0~46.0R-410A R-410A
1~/220-240V/50Hz 1~/220-240V/50Hz6.35 / 12.7 / 18 6.35 / 12.7 / 18
30 3020.0 20.0
FTN-F / RN-E
33
RN50,60EFTN50,60FARC433A72
Wall Mounted Unit
Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Auto-swing function ensures effi cient air distribution via louvers that close automatically when the unit is switched off
Automatic movable louver can be fi xed at any desired angle
Both horizontal fl aps and front panel can easily be removed and washed
All maintenance operations can be carried out from the front of the unit
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FAQ71BVV1B FAQ100BVV1BCapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps
optional optional
optional
7.10 7.10 10.00 10.00
2.68 2.81 2.81 2.84
1325 1265 1780 1760
D C C C
290x1050x230 360x1570x20013.0 26.0
19.0 / 15.0 23.0 / 19.059.0 / 53.0 61.0 / 57.059.0 / 53.0 61.0 / 57.043.0 / 37.0 45.0 / 41.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32083 81 102 99
-15.0~46.063.0 66.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FAQ-B / RR-B
34
RR100BFAQ71B BRC1D52 BRC7E619/C511
35
Flexi Type Unit
Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window
Consumes up to 30% less energy than non-inverter units
Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and
temperature distribution. Home leave operation saves energy during
absence Air purifi cation fi lter Powerful mode can be selected for rapid cooling
or heating Indoor / outdoor unit silent operation
optional 5 steps
standard
MXS
HEAT PUMP INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / HeatingAnnual energy consumption kWhEnergy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
FLXS25BAVMB FLXS35BAVMB FLXS50BAVMB
1.2 1.2 0.92.5 3.5 4.93.0 3.8 5.31.2 1.2 0.93.4 4.0 6.14.5 5.0 7.5
3.85 / 3.47 3.10 / 3.25 2.85 / 3.35
325 565 860A / B B / C C / C
490x1050x200 490x1050x200 490x1050x20016.0 16.0 17.0
7.60 / 6.80 / 6.00 / 5.2 8.60 / 7.60 / 6.60 / 5.6 11.40 / 10.00 / 8.50 / 7.69.20 / 8.30 / 7.40 / 6.6 9.80 / 8.90 / 8.00 / 7.2 12.1 / 9.8 / 7.5 / 6.8
53.0 54.0 63.0- - 62.0
37.0 / 34.0 / 31.0 / 28.0 38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.037.0 / 34.0 / 31.0 / 29.0 39.0 / 36.0 / 33.0 / 30.0 46.0 / 41.0 / 35.0 / 33.0
R-410A R-410A R-410A1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz
RXS25G2V1B RXS35G2V1B RXS50G2V1B550x765x285 550x765x285 735x825x300
34 34 48-10~46 -10~46 -10~46-15~20 -15~20 -15~18
61 63 6243 44 4444 45 4546 48 4847 48 48
R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 30
FLXS-B / RXS-G
36
RXS25,35GFLXS25,35,50BARC433A6
Flexi Type Unit
Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window
Consumes up to 30% less energy than non-inverter units
Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and
temperature distribution. Home leave operation saves energy during
absence Air purifi cation fi lter Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation
COOLING ONLY INVERTERIndoor UnitsIndoor Units FLKS25BAVMB FLKS35BAVMB FLKS50BAVMB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER NominalAnnual energy consumption kWhEnergy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS25G2V1B RKS35G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps
standard
MKS
1.2 1.2 0.92.5 3.5 4.93.0 3.8 5.3
3.85 3.70 2.85325 565 860A B C
490x1050x200 490x1050x200 490x1050x20016.0 16.0 17.0
7.60 / 6.80 / 6.00 / 5.2 8.60 / 7.60 / 6.6 / 5.6 11.40 / 10.00 / 8.50 / 7.553.0 54.0 63.0
37.0 / 34.0 / 31.0 / 28.0 38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.0R-410A R-410A R-410A
1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz
550x765x285 550x765x285 735x825x30034 34 48
-10~46 -10~46 -10~4661 63 6243 44 4446 48 48
R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 1820 20 30
FLKS-B / RKS-G
37
FLKS25,35,50BARC433A6 RKS25,35G
Flexi Type Unit
Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window
Consumes up to 30% less energy than non-inverter units
Washable front panel Reaches set temperature more quickly Auto-swing function ensures effi cient air and
temperature distribution. Home leave operation saves energy during
absence Air purifi cation fi lter Powerful mode can be selected for rapid cooling Indoor / outdoor unit silent operation
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FLKS50BAVMB Nominal Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RN50E3V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional 5 steps
standard
MKS
4.9
2.85
860
C
490x1050x20017.0
11.40 / 10.00 / 8.50 / 7.563.0
47.0 / 43.0 / 39.0 / 36.0R-410A
1~/220-240/220-230V/50/60Hz
735x825x30047
-10.0~46.061.047.0
R-410A1~/220-240V/50Hz
6.35 / 12.7 / 1830
20.0
FLKS-B / RN-E
38
RN50EFLKS50B FLKS50BARC433A6
Floor Standing Unit
Weekly timer: allows to program the unit on a weekly basis
Stylish design Flat front panel: its stylish appearance blends easily
within any interior décor and is more easy to clean. Titanium apatite photocatalytic air purifi cation fi lter Can be installed against a wall or recessed Dual air discharge fl ow for better air distribution ECONO mode decreases power consumption
so that other appliances that need large power supply can be used
Lightweight but sturdy design
HEAT PUMP INVERTERIndoor UnitsIndoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS25G2V1B RXS35G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
Titanium apatite photocatalytic air purifi cation fi lter
1.3 1.4 1.42.5 3.5 5.03.0 3.8 5.61.3 1.4 1.43.4 4.5 5.84.5 5.0 8.1
4.39 / 4.30 3.43 / 3.69 3.23 / 3.63
285 510 775
A / A A / A A / A600x700x210 600x700x210 600x700x210
14 14 148.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.68.8 / 6.9 / 5.0 / 4.4 9.4 / 7.3 / 5.2 / 4.7 11.8 / 10.1 / 8.5 / 7.1
54 55 5654 55 57
38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 3238 / 32 / 26 / 23 39 / 33 / 27 / 24 45 / 40 / 36 / 32
R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
550x765x285 550x765x285 735x825x30034 34 48
-10~46 -10~46 -10~46-15~20 -15~20 -15~18
61 63 6243 44 4444 45 4546 48 4847 48 48
R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 30
FVXS-F / RXS-G
39
RXS25,35GFVXS25,35,50FV1BARC452A1
Floor Standing Unit
Weekly timer: allows to program the unit on a weekly basis
Stylish design Flat front panel: its stylish appearance blends easily
within any interior décor and is more easy to clean. Titanium apatite photocatalytic air purifi cation fi lter Can be installed against a wall or recessed Dual air discharge fl ow for better air distribution ECONO mode decreases power consumption
so that other appliances that need large power supply can be used
Lightweight but sturdy design
COOLING ONLY INVERTERIndoor UnitsIndoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS25G2V1B RKS35G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
Titanium apatite photocatalytic air purifi cation fi lter
1.3 1.4 1.42.5 3.5 5.03.0 3.8 5.6
4.39 3.43 3.23285 510 775A A A
600x700x210 600x700x210 600x700x21014 14 14
8.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.654 55 56
38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 32R-410A R-410A R-410A
1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
550x765x285 550x765x285 735x825x30034 34 48
-10~46 -10~46 -10~4661 63 6243 44 4446 48 48
R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 1820 20 30
FVXS-F / RKS-G
40
RKS25,35GFVXS25,35,50FARC452A1
Floor Standing Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Very effi cient for use in rooms with high ceilings Quiet operation: down to 35 dBA sound pressure
level (71 class) Auto-swing function ensures effi cient air and
temperature distribution.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FVQ71BV1B FVQ100BV1B FVQ125BV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kWEER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
2 steps
optional
7.1 10 12.58 11.2 14
2.81 / 3.21 2.49 / 2.81 2.81 / 3.21
1,265 2,010 2,225C / C E / D C / C
1,850 x 600 x 270 1,850 x 600 x 350 1,850 x 600 x 35039 46 47
54 / 48 60 / 54 62 / 5654 / 48 60 / 54 62 / 5642 / 36 48 / 42 50 / 4442 / 36 48 / 42 50 / 44R-410A R-410A R-410A
1~ / 220-240V / 50Hz 1~ / 220-240V / 50Hz 1~ / 220-240V / 50Hz
770 x 900 x 320 700 x 900 x 320 1,170 x 900 x 32068 103
-5~46-15~15.5
65 6749 5151 55 5347 49
R-410A220-240V/50Hz9.52 / 15.9 / 26
30 500.5
FVQ-B / RZQS-C
41
RZQS125CFVQ-B
Slim Concealed Ceiling Unit
Slim design for fl exible installation Compact dimensions, can easily be mounted in a
ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing
buildings. Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling
or heating
Home leave operation saves energy during absence
Standard suction fi lter: removes airborne dust particles to ensure a steady supply of clean air
Indoor / outdoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .
Medium external static pressure facilitates unit use with fl exible ducts of varying lengths
HEAT PUMP INVERTERIndoor UnitsIndoor Units FDXS25EAVMB FDXS35EAVMB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS25G2V1B RXS35G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
1.3 1.42.4 3.43.0 3.81.3 1.43.2 4.04.5 5.0
3.48 / 3.52 3.12 / 3.39
345 545
A / B B / C200x700x620 200x700x620
21.0 21.08.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.28.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2
53.0 53.053.0 53.0
35.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.035.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0
R-410A R-410A1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz
550x765x285 550x765x28534 34
-10~46 -10~46-15~20 -15~20
61 6343 4444 4546 4847 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 9.52/1820 20
FDXS-E / RXS-G
42
RXS25,35GFDXS25,35EARC433A8
Slim Concealed Ceiling Unit
Slim design for fl exible installation Compact dimensions, can easily be mounted in a
ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing
buildings. Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling
or heating Home leave operation saves energy during
absence Standard suction fi lter: removes airborne dust
particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .
Medium external static pressure facilitates unit use with fl exible ducts of varying lengths
HEAT PUMP INVERTERIndoor UnitsIndoor Units FDXS50CVMB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
1.7
5.05.31.75.86.0
3.03 / 3.02825B / D
200x900x62027.0
12.0 / 11.0 / 10.0 / 8.412.0 / 11.0 / 10.0 / 8.4
55.055.0
37.0 / 35.0 / 33.0 / 31.037.0 / 35.0 / 33.0 / 31.0
R-410A1~/220-240/220-230V/50/60Hz
735x825x30048
-10~46-15~18
6244454848
R-410A1~/220-240V/50Hz
6.35 / 12.7/1830
FDXS-C / RXS-G
43
RXS50GFDXS50CARC433A8
Slim Concealed Ceiling Unit
Slim design for fl exible installation Compact dimensions, can easily be mounted in a
ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing
buildings. Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Powerful mode can be selected for rapid cooling
or heating Home leave operation saves energy during
absence Standard suction fi lter: removes airborne dust
particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .
Medium external static pressure facilitates unit use with fl exible ducts of varying lengths
HEAT PUMPIndoor UnitsIndoor Units FDXS60CVMBCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kWStandard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/min
Heating High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBA
Heating High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
5 steps
standard
optional
1.76.0
6.5
1.77.0
8.0
2.82 / 3.02
1065
C / D
200x1100x62030.0
16.0 / 14.8 / 13.5 / 11.216.0 / 14.8 / 13.5 / 11.2
56.056.0
38.0 / 36.0 / 34.0 / 32.038.0 / 36.0 / 34.0 / 32.0
R-410A220-240/220-230V/50/60Hz
735x825x30048
-10~46-15~18
63494946
R-410A220-240/220-230V/50Hz
6.35 / 12.7 / 1830
FDXS-C / RXS-F
44
RXS60FFDXS60CARC433A8
MXS
45
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
heat pump
optionalstandard
2 steps
35~50 optional
HEAT PUMP INVERTERIndoor UnitsIndoor UnitsCapacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / HeatingAnnual energy consumption kWhEnergy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
ColourHxWxD mmWeight kg
Outdoor UnitOutdoor UnitDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBA
Sound Pressure (High) Cooling dBAHeating dBA
Refrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
FBQ35B8V1 FBQ50B8V1- -
3.4 5.0- -- -
4.0 6.0- -
2.91 2.60
585 960
C E300x700x800 300x700x800
30 3111.5 / 9 14 / 1011.5 / 9 14 / 10
52 5352 53
33 / 29 33 / 2933 / 29 33 / 29R-410A R-410A
1~/230V/50Hz 1~/230V/50HzBYBS45D BYBS45D
55x800x500 55x800x5003.5 3.5
RXS35G2V1B RXS50G2V1B550x765x285 735x825x300
34 48-10~46 -10~46-15~20 -15~20
63 6144 4445 45
48 4848 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 12.7 / 1820 30
FBQ-B / RXS-G
46
RXS35GFBQ35,50BBRC1D52
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ60B8V1Capacity Cooling capacity Minimum kW
Standard kW
Maximum kWHeating capacity Minimum kW
Standard kW
Maximum kWEER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
standard heat pump
2 steps
35~60 optional
-5.7
--
7.0
-2.60 / 2.80
1095
E / E
300x1000x80041
19 / 1419 / 14
6060
34 / 3034 / 30R-410A
1~/230V/50HzBYBS71D
55x1100x5004.5
735x825x30048
-10~46-15~18
63494946
R-410A1~/220-240/220-230V/50Hz
6.35 / 12.7 / 1830
FBQ-B / RXS-F
47
RXS60FFBQ60BBRC1D52
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump optional
standard optional
2 steps
7.1 7.1 10.0 10.0 12.2
8.0 8.0 11.2 11.2 14.5
2.54 / 3.21 2.65 / 3.21 2.64 / 2.86 2.78 / 2.89 2.61 / 3.21
1395 1340 1895 1800 2335
E / C D / C D / D D / D D / C
300x1000x800 300x1400x80041.0 51.0 52.0
19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00
60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0
R-410A1~/230V/50Hz
BYBS71DJW1 BYBS125DJW1
55x1100x500 55x1500x5004.5 6.5
770x900x320 1170x900x32084 83 103 101 108
-5.0~46.0-10.0~15.0
63.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FBQ-B / RQ-B
48
RQ100, 125BFBQ100, 125BBRC1D52
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump optional
standard optional
2 steps
* Combination only available in Portugal, Greece, Cyprus and Malta
7.1 7.1 10 10 12.20
8 8 11.2 11.2 14.5
2.54 / 3.21 2.65 / 3.21 2.64 / 2.86 2.78 / 2.89 2.61 / 3.21
1395 1340 1895 1800 2335
E / C D / C D / D D / D D / C
300x1000x800 300x1400x80041.0 51.0 52.0
19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00
60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0
R-410A1~/230V/50Hz
BYBS71DJW1 BYBS125DJW1
55x1100x500 55x1500x5004.5 6.5
770x900x320 1170x900x32083 102 100 108
10.0~46.0-10~15
65.0 70.053.0 57.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26500.5
FBQ-B/ REQ-B*
49
REQ100,125BFBQ100,125BBRC1D52
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional
standard
2 steps
optional
7.1 10.0 12.5 13.4
8.0 11.2 14.0 15.5
2.82 / 3.33 2.61 / 3.23 2.84 / 3.3 2.70 / 3.11
1,260 1,915 2,200 2,485
C / C D / C C / C D / D
300x1000x800 300x1400x80041.0 51.0 52.0
19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00
60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0
R-410A1~/230V/50Hz
BYBS71DJW1 BYBS125DJW1
55x1100x500 55x1500x5004.5 6.5
770x900x320 700x900x320 1,170x900x320 1170x900x32068 103
-5~46-15~15.5
65 67 6849 51 5251 55 53 5447 49 50
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2630 50
0.5
FBQ-B / RZQS-C
50
RZQS125,140CBRC1D52 FBQ100,125,140B
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional
standard
2 steps
optional
7.1 10.0 12.5 13.4
8.0 11.2 14.0 15.5
3.21 / 3.76 3.33 / 3.75 3.14 / 3.52 2.81 / 3.21
1,105 1500 1985 2385
A / A B / B C / C
300x1000x800 300x1400x80041.0 51.0 52.0
19.00 / 14.00 27.00 / 20.00 35.00 / 24.0019.00 / 14.00 27.00 / 20.00 35.00 / 24.00
60.0 62.0 63.034.0 / 30.0 36.0 / 31.0 38.0 / 32.034.0 / 30.0 36.0 / 31.0 38.0 / 32.0
R-410A1~/230V/50Hz
BYBS71DJW1 BYBS125DJW1
55x1100x500 55x1500x5004.5 6.5
770x900x320 1170x900x32067 103
-15.0~50.0-20.0~15.5
63 65 66 6747 49 5049 51 5243 45 46
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2650 75
0.5
FBQ-B / RZQ-C
51
RZQ100,125,140CBRC1D52 FBQ100,125,140B
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
HEAT PUMP INVERTERIndoor UnitsIndoor Units FBQ100B8V3B FBQ125B8V3B FBQ140B8V3BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional
standard
2 steps
optional
10,00 12,50 13,40
11,20 14,00 15,50
3,50 / 3,73 3,14 / 3,51 2,82 / 3,21
1430 1990 2380
A / A B / B C / C
300x1400x80051,0 52,0
27,00 / 20,00 35,00 / 24,0027,00 / 20,00 35,00 / 24,00
62,0 63,036,0 / 31,0 38,0 / 32,036,0 / 31,0 38,0 / 32,0
R-410A1~/230V/50HzBYBS125DJW1
55x1500x5006,5
1345x900x320106
-15,0~50,0-20,0~15,5
65,0 66,049,0 50,051,0 52,0
45,0R-410A
3N~/400V/50Hz9,52 / 15,9 / 26
750,5
FBQ-B / RZQ-BW1
52
FBQ100,125,140B RZQ100,125,140BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA
Heating Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps: FDQ250, 3 steps: FDQ125,200
optional heat pump
12.5
14.6
2.61 / 3.24
2395
D / C
350x1400x66259.043.043.075.044.044.0
R-410A1~/230V/50Hz
1170x900x320108
-5.0~46.0-10.0~15.0
67.053.0
R-410A3N~/400V/50Hz9.52 / 15.9 / 26
700.5
FDQ-B / RQ-B
53
RQ125BFDQ125BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA
Heating Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQS125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps: FDQ250, 3 steps: FDQ125,200
standard
optional heat pump
12.5
14.0
2.81 / 3.43
2,225
C / B
350x1400x66259.043.043.075.044.044.0
R-410A1~/230V/50Hz
1,170x900x320103
-5~46-15~15.5
67515349
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 26500.5
FDQ-B / RZQS-C
54
RZQS125CFDQ125BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA
Heating Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps: FDQ250, 3 steps: FDQ125,200
optional standard heat pump
12.5
14.0
3.01 / 3.81
2075
B / A
350x1400x66259.043.043.075.044.044.0
R-410A1~/230V/50Hz
1170x900x320103
-15.0~50.0-20.0~15.5
66505245
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 26750.5
FDQ-B / RZQ-C
55
RZQ125CFDQ-BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ125B8V3B9Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA
Heating Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
2 steps: FDQ250, 3 steps: FDQ125,200
heat pump
optional standard
12.50
14.00
3.01 / 3.79
2075
B / A
350x1400x66259.043.043.075.044.044.0
R-410A1~/230V/50Hz
1345x900x320106
-15.0~50.0-20.0~15.5
66.050.052.045.0
R-410A3N~/400V/50Hz9.52 / 15.9 / 26
750.5
FDQ-B / RZQ-BW1
56
RZQ125BFDQ-BBRC1D52
57
Concealed Ceiling Unit
Lightweight and compact Both discharge and suction ducts can be easily
connected via fl anges on the unit The air fi lter is easily accessible from underneath,
even after the installation of the ducts. The fi lter can therefore be easily washed or vacuumed
Extremely quiet in operation. Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Maximum external static pressure (ESP) is 100Pa
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDEQ71B8V3B FDEQ100B8V3B FDEQ125B8V3BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m* Combination only available in Portugal, Greece, Cyprus and Malta
(optional) (3 steps)
heat pump
7.1 7.1 9.8 9.8 12.50
8 8 11.2 11.2 14.60
2.54 / 3.21 2.65 / 3.21 2.46 / 2.81 2.49 / 2.83 2.68 / 3.23
1395 1340 1990 1970 2335
E / C D / C E / D E / D D / C
279x987x750 279x1387x75038.1 48.6
19.0 / 14.0 27.0 / 20.0 35.0 / 24.019.0 / 14.0 27.0 / 20.0 35.0 / 24.0
63.0 65.0 66.037.0 / 33.0 39.0 / 34.0 41.0 / 35.037.0 / 33.0 39.0 / 34.0 41.0 / 35.0
R-410A1~/230V/50Hz
770x900x320 1170x900x32083 102 100 108
10.0~46.0-10~15
65.0 70.053.0 57.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26500.5
FDEQ-B / REQ-B*
58
REQ100BFDEQ125BBRC1D52
Slim Concealed Ceiling Unit
Slim design for fl exible installation Compact dimensions, can easily be mounted in a
ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing
buildings. Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Home leave operation saves energy during
absence Standard suction fi lter: removes airborne dust
particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .
Medium external static pressure facilitates unit use with fl exible ducts of varying lengths
Powerful mode can be selected for rapid cooling
COOLING ONLY INVERTERIndoor UnitsIndoor Units FDKS25EAVMB FDKS35EAVMB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS25G2V1B RKS35G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
1.3 1.42.4 3.43.0 3.8
3.48 3.123.45 5.45
A B200x700x620 200x700x620
21.0 21.08.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2
53.0 53.035.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0
R-410A R-410A1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz
550x765x285 550x765x28534 34
-10~46 -10~4661 6343 4446 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 9.52 / 1820 20
FDKS-E / RKS-G
59
FDKS25,35EARC433A8 RKS25,35G
Slim Concealed Ceiling Unit
Slim design for fl exible installation Compact dimensions, can easily be mounted in a
ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing
buildings. Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Home leave operation saves energy during
absence Standard suction fi lter: removes airborne dust
particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) .
Medium external static pressure facilitates unit use with fl exible ducts of varying lengths
Powerful mode can be selected for rapid cooling
COOLING ONLY INVERTERIndoor UnitsIndoor Units FDKS50CVMB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
5 steps standard
1.75.05.3
3.038.25
B200x900x620
27.012.0 / 11.0 / 10.0 / 8.4
55.037.0 / 35.0 / 33.0 / 31.0
R-410A1~220-240/220-230V/50/60Hz
735x825x30048
-10~46624448
R-410A220-240V/50Hz6.35 / 12.7 / 18
30
FDKS-C / RKS-G
60
FDKS50CARC433A8 RKS50G
Slim Concealed Ceiling Unit
Slim design for fl exible installation Compact dimensions, can easily be mounted in a
ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Home leave operation saves energy during
absence Standard suction fi lter: removes airborne dust
particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A)
Medium external static pressure facilitates unit use with fl exible ducts of varying lengths
Powerful mode can be selected for rapid cooling
COOLING ONLY INVERTERIndoor UnitsIndoor Units FDKS60CVMBCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Medium/Low/Silent Operation m³/minSound Power Cooling High dBASound Pressure Cooling High/Medium/Low/Silent Operation dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
5 steps
standard optional
1.76.0
6.5
2.82
1065
C
200x1100x62030.0
16.0 / 14.8 / 13.5 / 11.256.0
38.0 / 36.0 / 34.0 / 32.0R-410A
220-240/220-230V/50/60Hz
735x825x30047
-10~4663
49(H) - 46(SL)R-410A
220-240V/50Hz6.35 / 12.7 / 18
30
FDKS-C / RKS-F
61
RKS60FFDKS60CARC433A8
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
COOLING ONLY INVERTERIndoor UnitsIndoor Units FBQ35B8V1 FBQ50B8V1 Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour White WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RKS35G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optionalstandard
2 steps
50
optional
- -3.4 5.0- -
2.91 2.60
585 960
C E300x700x800 300x700x800
30 3111.5 / 9 14 / 10
52 5333 / 29 33 / 29R-410A R-410A
1~/230V/50Hz 1~/230V/50HzBYBS45D BYBS45D
55x800x500 55x800x5003.5 3.5
550x765x285 735x825x30034 48
-10~46 -10~4662 6144 4448 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 12.7/1820 30
FBQ-B / RKS-G
62
FBQ35,50BBRC1D52 RKS35G
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
COOLING ONLY INVERTERIndoor UnitsIndoor Units FBQ60B8V1Capacity Cooling capacity Minimum kW
Standard kW
Maximum kWEER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RKS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
standard optional
2 steps
60
-5.7
-2.601095
E300x1000x800
4119 / 14
6060
34 / 30R-410A
1~/230V/50HzBYBS71D
55x1100x5004.5
735x825x30047
-10~4663
49(H) - 46(SL)R-410A
1~/220-240V/50Hz6.35 / 12.7 / 18
20
FBQ-B / RKS-F
63
RKS60FFBQ60BBRC1D52
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FBQ50B8V1 FBQ60B8V1 Nominal Capacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour White WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RN50E3V1B RN60E3V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
standard optional
2 steps
60
5.0 5.7
2.60 2.60
960 1095
E E
300x700x800 300x1000x80031 41
14 / 10 19 / 1453 60
33 / 29 34 / 30R-410A R-410A
1~/230V/50Hz 1~/230V/50HzBYBS45D BYBS71D
55x800x500 55x1100x5003.5 4.5
735x825x300 735x825x30047 47
-10.0~46.0 -10.0~46.061.0 63.047.0 49.0
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 12.7 / 18 6.35 / 12.7 / 1830 3020 20
FBQ-B / RN-E
64
RN50,60EFBQ60BBRC1D52
Concealed Ceiling Unit
Lightweight and compact Slim design for fl exible installation Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible The position of individual air discharge grilles
can be altered, enabling effi cient temperature distribution, even in irregularly shaped rooms.
Optimum air distribution Quiet operation Maximum external static pressure (ESP) is 88Pa
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3BCapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour WhiteHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
standard optional
2 steps
7.10 7.10 10.00 10.00 12.20
2.54 2.65 2.64 2.78 2.61
1395 1340 1895 1800 2335
E D D D D
300x1000x800 300x1400x80041.0 51.0 52.0
19.00 / 14.00 27.00 / 20.00 35.00 / 24.0060.0 62.0 63.0
34.0 / 30.0 36.0 / 31.0 38.0 / 32.0R-410A
1~/230V/50HzBYBS71DJW1 BYBS125DJW1
55x1100x500 55x1500x5004.5 6.5
770x900x320 1170x900x32083 81 102 99 106
-15.0~46.063.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FBQ-B / RR-B
65
RR71BFBQ71BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FDQ125B8V3BCapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RR125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional
3 steps: FDQ125,200
optional
12.50
2.61
2395
D
350x1400x66259.043.075.044.0
R-410A1~/230V/50Hz
1170x900x320106
-15.0~46.067.053.0
R-410A3N~/400V/50Hz9.52 / 15.9 / 26
700.5
FDQ-B / RR-B
66
RR125BFDQ125BBRC1D52
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class
35-50 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / heating
Annual energy consumption kWh
Energy label Cooling / heatingDimensions (Height x width x depth) mmWeight kgAir fl ow rate Cooling High/low m³/min
Heating High/low m³/minSound power Cooling High dBASound pressure Cooling High/low dBA
Heating High/low dBARefrigerant TypePower supplyDecoration panel Model
Colour Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RXS35G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
heat pump
optional
2 steps optional
optional standard
1.4 0.93.4 5.03.7 5.61.4 0.94.2 6.05.0 7.0
3.58/3.41 3.55/3.70475 705
A/B A204x840x840 204x840x840
19 1910.5 / 8.5 12.5 / 8.5
12.5 / 10.0 12.5 / 8.549 49
31 / 27 31 / 2731 / 27 31 / 27R-410A R-410A
1~/220-240V/50/60Hz 1~/220-240V/50/60HzBYCQ140CW1 BYCQ140CW1
50x950x950 50x950x9505.5 5.5
550x765x285 735x825x30034 48
-10~46 -10~46-15~20 -15~20
63 6144 4445 4548 4848 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 12.7/1820 30
FCQ-C / RXS-G
67
RXS35GFCQ35,50C BRC1D52 BRC7E63
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class 60 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ60C7VEBCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional heat pump
2 steps optional
optional standard
0.95.7
6.0
0.97.0
8.0
3.48 / 3.52
820
A / B
204x840x84019
13.5 / 8.513.5 / 8.5
5133 / 2833 / 28R-410A
1~/220-240V/50/60HzBYCQ140CW1
50x950x9505.5
735x825x30048
-10~46-15~18
63494946
R-410A1~/220-240/220-230V/50Hz
6.35 / 12.7 / 1830
FCQ-C / RXS-F
68
RXS60F FCQ60C BRC1D52 BRC7F532
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class 71 Easy visible drain check thanks to clear drain socket
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional optional
2 steps optional
standard
7.1 7.1 10.0 10.0 12.5
8.0 8.0 11.2 11.2 14.6
2.61 / 2.81 2.67 / 2.86 2.61 / 2.99 2.81 / 3.06 2.68 / 2.89
1360 1330 1915 1780 2330
D / D D / D D / D C / D D / D
204x840x840 246x840x84021 23
15.5 / 9.0 23.5 / 16.0 27.5 / 19.016.0 / 9.5 23.5 / 16.0 27.5 / 19.0
51 54 5833 / 28 37 / 32 41 / 3534 / 28 37 / 32 41 / 35
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
770x900x320 1170x900x32084 83 103 101 108
-5.0~46.0-10.0~15.0
63.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FCQ-C / RQ-B
69
RQ100BFCQ100,125C BRC1D52 BRC7F532
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class 71 Easy visible drain check thanks to clear drain socket
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEBNominal Capacity Cooling capacity Standard kW 7.1 7.1 10.0 10.0 12.5
Heating capacity Standard kW 8.0 8.0 11.2 11.2 14.6
EER / COP Cooling / Heating 2.61 / 2.81 2.67 / 2.86 2.61 / 2.99 2.81 / 3.06 2.68 / 2.89
Annual energy consumption kWh 1360 1330 1915 1780 2330
Energy Label cooling / heating D / D D / D C / D D / D
Dimensions (Height x Width x Depth) mm 204x840x840 246x840x840 246x840x840Weight kg 21 23 23Air Flow Rate Cooling High/Low m³/min 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0
Heating High/Low m³/min 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0Sound Power Cooling High dBA 51 54 58Sound Pressure Cooling High/Low dBA 33 / 28 37 / 32 41 / 35
Heating High/Low dBA 34 / 28 37 / 32 41 / 35Refrigerant Type R-410A R-410A R-410APower Supply 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz 1~/220-240V/50/60HzDecoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1
Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mm 50x950x950 50x950x950 50x950x950
Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mm 770x900x320 1170x900x320Weight kg 83 102 100 108Sound pressure level Cooling dBA 53 53 57 57 57Sound power level Cooling dBA 65 65 70 70 70Operation Range Cooling Min~Max °CDB 10.0~46.0
Heating Min~Max °CWB -10~15Refrigerant Type R-410APower Supply 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50HzPiping connections Liquid (OD)/Gas/Drain mm 9.52 / 15.9 / 26Piping Length (Maximum) m 50Max. internunit level difference m 0.5* Combination only available in Portugal, Greece, Cyprus and Malta
heat pump
optional
2 steps optional
optional
standard
70
FCQ-C / REQ-B*
REQ100,125BBRC7F532 FCQ100,125CBRC1D52
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class 71 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pumpoptional
2 steps optional
optional standard
7.1 10.0 12.5 14.0
8.0 11.2 14.0 16.0
2.89 / 3.07 2.61 / 3.23 3.02 / 3.1 2.61 / 2.81
1,230 1,915 2,070 2,680
C / D D / C B / D D / D
204x840x840 246x840x84021 23
15.5 / 9.0 23.5 / 16.0 27.5 / 19.016.0 / 9.5 23.5 / 16.0 27.5 / 19.0
51 54 5833 / 28 37 / 32 41 / 3534 / 28 37 / 32 41 / 35 42 / 35
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
770x900x320 700x900x320 1,170x900x320 1170x900x32068 103
-5~46-15~15.5
65 67 6849 51 5251 55 53 5447 49 50
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2630 50
0.5
FCQ-C / RZQS-C
71
RZQS125,140CFCQ100,125,140C BRC1D52 BRC7E63
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class 71 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pumpoptional
2 steps optional
optional standard
7.1 10.0 12.5 14.0
8.0 11.2 14.0 16.0
3.36 / 3.62 3.61 / 3.71 3.22 / 3.54 2.61 / 3.21
1,055 1385 1940 2680
A / A A / B D / C
204x840x840 246x840x84021 23
15.5 / 9.0 23.5 / 16.0 27.5 / 19.016.0 / 9.5 23.5 / 16.0 27.5 / 19.0
51 54 5833 / 28 37 / 32 41 / 3534 / 28 37 / 32 41 / 35 42 / 35
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
770x900x320 1170x900x32067 103
-15.0~50.0-20.0~15.5
63 65 66 6747 49 5049 51 5243 45 46
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2650 75
0.5
FCQ-C / RZQ-C
72
RZQ100,125,140CFCQ71C BRC1D52 BRC7E63
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQ100C7VEB FCQ125C7VEB FCQ140C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pumpoptional
2 steps optional
optional standard
10.0 12.50 14.00
11.20 14.00 16.00
3.79 / 3.57 3.22 / 3.21 2.61 / 2.81
1320 1940 2680
A / B A / C D / D
246x840x84023
23.5 / 16.0 27.5 / 19.023.5 / 16.0 27.5 / 19.0
54 5837 / 32 41 / 3537 / 32 41 / 35 42 / 35
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
1345x900x320106
-15.0~50.0-20.0~15.5
65.0 66.049.0 50.051.0 52.0
45.0R-410A
3N~/400V/50Hz9.52 / 15.9 / 26
750.5
FCQ-C / RZQ-BW1
73
RZQ100,125,140BFCQ100,125,140C BRC1D52 BRC7E63
74
Round Flow Cassette
Improved operating effi ciency Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pumpoptional
2 steps optional
optional standard
7.1 10.0 12.5 14.0
8.0 11.2 14.0 16.0
3.01 / 3.41 2.81 / 3.41 3.22 / 3.41 2.81 / 3.21
1,180 1,780 1,940 2,490
B / B C / B A / B C / C
246x840x840 288x840x84023 25
20.0 / 12.0 32.5 / 18.0 32.5 / 21.520.0 / 12.0 32.5 / 18.0 32.5 / 21.5
52 6034 / 28 43 / 32 43 / 36 43 / 3834 / 28 43 / 32 43 / 36 43 / 38
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
770x900x320 700x900x320 1,170x900x320 1170x900x32068 103
-5~46-15~15.5
65 67 6849 51 5251 55 53 5447 49 50
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2630 50
0.5
FCQH-C / RZQS-C
75
RZQS125,140CFCQH100,125,140C BRC1D52 BRC7F532
Round Flow Cassette
Improved operating effi ciency Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pumpoptional
2 steps optional
optional standard
7.1 10.0 12.5 14.0
8.0 11.2 14.0 16.0
3.59 / 4.06 3.76 / 4.39 3.38 / 3.92 3.02 / 3.61
990 1330 1850 2320
A / A B / A
246x840x840 288x840x84023 25
20.0 / 12.0 32.5 / 18.0 32.5 / 21.520.0 / 12.0 32.5 / 18.0 32.5 / 21.5
52 6034 / 28 43 / 32 43 / 36 43 / 3834 / 28 43 / 32 43 / 36 43 / 38
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
770x900x320 1170x900x32067 103
-15.0~50.0-20.0~15.5
63 65 66 6747 49 5049 51 5243 45 46
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2650 75
0.5
FCQH-C / RZQ-C
76
FCQH100,125,140C BRC1D52 BRC7F532 RZQ100,125,140C
Round Flow Cassette
Improved operating effi ciency Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
HEAT PUMP INVERTERIndoor UnitsIndoor Units FCQH100C7VEB FCQH125C7VEB FCQH140C7VEBCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pumpoptional
2 steps optional
optional standard
10.00 12.50 14.00
11.20 14.00 16.00
4.10 / 4.38 3.53 / 3.90 3.01 / 3.54
1220 1770 2325
A / A B / B
288x840x84025
32.5 / 18.0 32.5 / 21.532.5 / 18.0 32.5 / 21.5
6043 / 32 43 / 36 43 / 3843 / 32 43 / 36 43 / 38
R-410A1~/220-240V/50/60Hz
BYCQ140CW1
50x950x9505.5
1345x900x320106
-15.0~50.0-20.0~15.5
65.0 66.049.0 50.051.0 52.0
45.0R-410A
3N~/400V/50Hz9.52 / 15.9 / 26
750.5
FCQH-C / RZQ-BW1
77
RZQ100,125,140BFCQH100,125,140C BRC1D52 BRC7F532
4-Way Blow Ceiling Mounted Cassette (600mm x 600mm)
New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles
Modern style decoration panel in white (RAL9010)
Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy
installation in corners Auto-swing function ensures effi cient air and
temperature distribution and prevents ceiling soiling.
Excellent low draught characteristics Easy installation and maintenance
The switch box can be reached by simply removing the suction grille; therefore maintenance can be done very easily.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RXS25G2V1B RXS35G2V1B RXS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
heat pump
optional standard
2 steps optionaloptional
- - -2.5 3.4 4.7- - -- - -
3.2 4.0 5.5- - -
3.42/3.48 3.09/3.33 2.61/2.81
365 550 900
A/B B/C D286x575x575 286x575x575 286x575x575
17.5 17.5 17.59.0 / 6.5 10.0 / 6.5 12.0 / 8.09.0 / 6.5 10.0 / 6.5 12.0 / 8.0
46.5 49.0 53.029.5 / 24.5 32.0 / 25.0 36.0 / 27.029.5 / 24.5 32.0 / 25.0 36.0 / 27.0
R-410A R-410A R-410A1~/230V/50Hz 1~/230V/50Hz 1~/230V/50HzBYFQ60BAW1 BYFQ60BAW1 BYFQ60BAW1
55x700x700 55x700x700 55x700x7002.7 2.7 2.7
550x765x285 550x765x285 735x825x30034 34 48
-10~46 -10~46 -10~46-15~20 -15~20 -15~20
61 63 6143 44 4444 45 4546 48 4847 48 48
R-410A R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/1820 20 30
FFQ-B / RXS-G
78
RXS25,35GFFQ-B BRC1D52 BRC7E531
4-way Blow Ceiling Mounted Cassette (600mm x 600mm)
New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles
Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation
in corners Auto-swing function ensures effi cient air and
temperature distribution and prevents ceiling soiling.
Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply
removing the suction grille; therefore maintenance can be done very easily.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FFQ60B8V1BCapacityCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label Cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional standard heat pump
2 steps optional
optional
5.8
7.0
2.80 / 2.81
1035
D / D
286x575x57517.5
15.0 / 10.015.0 / 10.0
58.041.0 / 32.041.0 / 32.0
R-410A1~/230V/50HzBYFQ60BAW1
55x700x7002.7
735x825x30048
-10~46-15~18
63494946
R-410A1~/220-240/220-230V/50Hz
6.35 / 12.7 / 1830
FFQ-B / RXS-F
79
RXS60FFFQ60B BRC1D52 BRC7E531
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class 35-50 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
COOLING ONLY INVERTERIndoor UnitsIndoor Units FCQ35C7VEB FCQ50C7VEB Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
ColourHxWxD mmWeight kg
Outdoor UnitOutdoor Unit RKS35G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
2 steps optional
optional
1.4 0.93.4 5.03.7 5.6
3.58 3.55475 705A A
204x840x840 204x840x84019 19
10.5 / 8.5 12.5 / 8.549 49
31 / 27 31 / 27R-410A R-410A
1~/220-240V/50Hz/60Hz 1~/220-240V/50Hz/60HzBYCQ140CW1 BYCQ140CW1
50x950x950 50x950x9505.5 5.5
550x765x285 735x825x30034 48
-10~46 -10~4662 6144 4448 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 12.7 / 1820 30
FCQ-C / RKS-G
80
FCQ35,50C BRC1D52 BRC7E63 RKS35G
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class 66 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
COOLING ONLY INVERTERIndoor UnitsIndoor Units FCQ60C7VEBCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RKS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional optional
2 steps optional
0.95.7
6.0
3.48
820
A204x840x840
1913.5 / 8.5
5133 / 28R-410A
-BYCQ140CW1
50x950x9505.5
735x825x30047
-10~4663
49(H) - 46(SL)R-410A
1~/220-240V/50Hz6.35 / 12.7 / 18
30
FCQ-C / RKS-F
81
RKS60FFCQ60C BRC1D52 BRC7F533
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214mm for class 50-60 Easy visible drain check thanks to clear drain socket
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FCQ50C7VEB FCQ60C7VEB Nominal Capacity Cooling capacity Standard kW 5.0 5.7
EER Nominal 3.55 3.48
Annual energy consumption kWh 705 820
Energy Label cooling A A
Dimensions (Height x Width x Depth) mm 204x840x840 204x840x840Weight kg 19 19Air Flow Rate Cooling High/Low m³/min 12.5 / 8.5 13.5 / 8.5Sound Power Cooling High dBA 49 51Sound Pressure Cooling High/Low dBA 31 / 27 33 / 28Refrigerant Type R-410A R-410APower Supply 1~/220-240V/50/60Hz 1~/220-240V/50/60HzDecoration Panel Model BYCQ140CW1 BYCQ140CW1
Colour Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mm 50x950x950 50x950x950
Outdoor UnitOutdoor Unit RN50E3V1B RN60E3V1B Dimensions (Height x Width x Depth) mm 735x825x300 735x825x300Weight kg 47 47Sound pressure level Cooling H dBA 47 49Sound power level Cooling H dBA 61 63Operation Range Cooling Min~Max °CDB -10.0~46.0 -10.0~46.0Refrigerant Type R-410A R-410APower Supply 1~/220-240V/50Hz 1~/220-240V/50HzPiping connections Liquid (OD)/Gas/Drain mm 6.35 / 12.7 / 18 6.35 / 12.7 / 18Piping Length (Maximum) m 30 30Max. internunit level difference m 20 20
optional
2 steps optional
optional
82
FCQ-C / RN-E
RN50,60EBRC7F533 FCQ50,60CBRC1D52
Round Flow Cassette
Modern style decoration panel in white (RAL9010) 360° air discharge ensures uniform air fl ow and
temperature distribution Air discharge from the corners avoids dead zones
that may be subject to temperature differences Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214mm for class 71 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEBCapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional optional
2 steps optional
7.10 7.10 10.00 10.00 12.50
2.61 2.67 2.61 2.81 2.68
1360 1330 1915 1780 2330
D D D C D
204x840x840 246x840x84021 23
15.5 / 9.0 23.5 / 16.0 27.5 / 19.051 54 58
33 / 28 37 / 32 41 / 35R-410A
-BYCQ140CW1
50x950x9505.5
770x900x320 1170x900x32083 81 102 99 106
-15.0~46.063.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FCQ-C / RR-B
83
RR100BFCQ100,125C BRC1D52 BRC7F533
4-Way Blow Ceiling Mounted Cassette (600mm x 600mm)
New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles
Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation
in corners Auto-swing function ensures effi cient air and
temperature distribution and prevents ceiling soiling.
Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply
removing the suction grille; therefore maintenance can be done very easily.
COOLING ONLY INVERTERIndoor UnitsIndoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RKS25G2V1B RKS35G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional standard
2 steps optional
optional
- - -2.5 3.4 4.7- - -
3.42 3.09 2.61
365 550 900A B D
286x575x575 286x575x575 286x575x57517.5 17.5 17.5
9.0 / 6.5 10.0 / 6.5 12.0 / 8.046.5 49.0 53.0
29.5 / 24.5 32.0 / 25.0 36.0 / 27.0R-410A R-410A R-410A
1~/230V/50Hz 1~/230V/50Hz 1~/230V/50HzBYFQ60BAW1 BYFQ60BAW1 BYFQ60BAW1
55x700x700 55x700x700 55x700x7002.7 2.7 2.7
550x765x285 550x765x285 735x825x30034 34 48
-10~46 -10~46 -10~4661 62 6143 44 4446 48 48
R-410A R-410A R-410A
1~/220-240V/50Hz 1~/220-240V/50Hz 1~/220-240V/50Hz6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 18
20 20 30
FFQ-B / RKS-G
84
FFQ-B BRC1D52 BRC7E531 RKS25,35G
4-way Blow Ceiling Mounted Cassette (600mm x 600mm)
New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles
Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation
in corners Auto-swing function ensures effi cient air and
temperature distribution and prevents ceiling soiling.
Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply
removing the suction grille; therefore maintenance can be done very easily.
COOLING ONLY INVERTERIndoor UnitsIndoor Units FFQ60B8V1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kWEER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RKS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional standard optional
2 steps optional
-5.8
-2.80
1035
D286x575x575
17.515.0 / 10.0
58.041.0 / 32.0
R-410A1~/230V/50HzBYFQ60BAW1
55x700x7002.7
735x825x30047
-10~4663
49(H) - 46(SL)R-410A
1~/220-240V/50Hz6.35 / 12.7 / 18
30
FFQ-B / RKS-F
85
RKS60FFFQ60BBRC1D52 BRC7E531
4-way Blow Ceiling Mounted Cassette (600mm x 600mm)
New and extremely compact casing (575mm in width and depth) enables unit to fi t fl ush into ceilings and match standard architectural modules, without cutting ceiling tiles
Modern style decoration panel in white (RAL9010) Slim design for fl exible installation Ideal for shops, restaurants or offi ces requiring
maximum fl oor space for furniture, decorations and fi ttings
Extremely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation
in corners Auto-swing function ensures effi cient air and
temperature distribution and prevents ceiling soiling.
Excellent low draught characteristics Easy installation and maintenance The switch box can be reached by simply
removing the suction grille; therefore maintenance can be done very easily.
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FFQ50B8V1B FFQ60B8V1B Nominal Capacity Cooling capacity Standard kW
Minimum kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High dBASound Pressure Cooling High/Low dBARefrigerant TypePower SupplyDecoration Panel Model
Colour Pure White (RAL 9010) Pure White (RAL 9010)HxWxD mmWeight kg
Outdoor UnitOutdoor Unit RN50E3V1B RN60E3V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling H dBASound Pressure Cooling H dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional standard optional
2 steps optional
4.7 5.8
- -- -
2.61 2.80
900 1035
D D
286x575x575 286x575x57517.5 17.5
12.0 / 8.0 15.0 / 10.053.0 58.0
36.0 / 27.0 41.0 / 32.0R-410A R-410A
1~/230V/50Hz 1~/230V/50HzBYFQ60BAW1 BYFQ60BAW1
55x700x700 55x700x700 2.7 2.7
735x825x300 735x825x30047 47
-10.0~46.0 -10.0~46.061.0 63.047.0 49.0
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 12.7 / 18 6.35 / 12.7 / 1830 3020 20
FFQ-B / RN-E
86
RN50,60EFFQ50,60BBRC1D52 BRC7E531
4-Way Blow Ceiling Suspended Cassette
Can be installed in both new and existing buildings.
Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation
in corners Air fi lter, drain pan and heat exchanger fi n are
mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump optional
standard optional
2 steps optional
7.1 7.1 10.0 10.0 12.2
8.0 8.0 11.2 11.2 14.5
2.63 / 3.16 2.68 / 3.28 2.61 / 3.13 2.65 / 3.16 2.67 / 2.97
1350 1325 1915 1890 2285
D / D D / C D / D D / D D / D
165x895x895 230x895x89525.0 31.0
19.0 / 14.0 29.0 / 21.0 32.0 / 23.019.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32084 83 103 101 108
-5.0~46.0-10.0~15.0
63.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FUQ-B / RQ-B
87
RQ100BFUQ71B BRC1D52 BRC7C529
4-Way Blow Ceiling Suspended Cassette
Can be installed in both new and existing buildings.
Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation
in corners Air fi lter, drain pan and heat exchanger fi n are
mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install
HEAT PUMP INVERTERIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optional
standard
2 steps optional
optional
7.1 10 12.5
8.0 11.2 14.0
3.21 / 3.42 3.21 / 3.32 3.01 / 3.23
1,105 1560 2075
A / B A / C B / C
165x895x895 230x895x89525.0 31.0
19.0 / 14.0 29.0 / 21.0 32.0 / 23.019.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32067 103
-15.0~50.0-20.0~15.5
63 65 6647 49 5049 51 5243 45
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2650 75
0.5
FUQ-B / RZQ-C
FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B
RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B
88
FUQ-B BRC1D52 BRC7C529 RZQ100,125C
4-Way Blow Ceiling Suspended Cassette
Can be installed in both new and existing buildings.
Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation
in corners Air fi lter, drain pan and heat exchanger fi n are
mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install
HEAT PUMP INVERTERIndoor UnitsIndoor Units FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump
optionalstandard
2 steps optional
optional
10.00 12.50
11.20 14.00
3.21 / 3.41 3.09 / 3.21
1560 2025
A / B B / C
230x895x89531.0
29.0 / 21.0 32.0 / 23.029.0 / 21.0 32.0 / 23.059.0 / 54.0 60.0 / 55.059.0 / 54.0 60.0 / 55.043.0 / 38.0 44.0 / 39.043.0 / 38.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
1345x900x320106
-15.0~50.0-20.0~15.5
65.0 66.049.0 50.051.0 52.0
45.0R-410A
3N~/400V/50Hz9.52 / 15.9 / 26
750.5
FUQ-B / RZQ-BW1
89
RZQ100,125BFUQ-B BRC1D52 BRC7C529
4-Way Blow Ceiling Suspended Cassette
Can be installed in both new and existing buildings.
Ideal for shops, restaurants or offi ces requiring maximum fl oor space for furniture, decorations and fi ttings
Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5m
without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation
in corners Air fi lter, drain pan and heat exchanger fi n are
mildew proof and anti-bacterial treated. Drain-up pump with 500mm lift fi tted as standard Easy to install
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1BCapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump optional
standard optional
2 steps optional
7.10 7.10 10.00 10.00 12.20
2.63 2.68 2.61 2.65 2.67
1350 1325 1915 1890 2285
D D D
165x895x895 230x895x89525.0 31.0
19.0 / 14.0 29.0 / 21.0 32.0 / 23.056.0 / 51.0 59.0 / 54.0 60.0 / 55.056.0 / 51.0 59.0 / 54.0 60.0 / 55.040.0 / 35.0 43.0 / 38.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32083 81 102 99 106
-15.0~46.063.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FUQ-B / RR-B
90
RR71BFUQ71B BRC1D52 BRC7C529
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1BCapacity Cooling capacity Minimum kW
Standard kWMaximum kW
Heating capacity Minimum kWStandard kWMaximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label Cooling / heatingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS35G2V1B RXS50G2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Low) Cooling dBA
Heating dBASound Pressure (High) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
heat pump 2 steps
optional
35~50 optionaloptional optional
1.4 1.73.4 5.03.7 5.61.2 1.74.0 6.05.0 7.0
3.24 / 3.60 2.73 / 2.93
525 915
A / A D / C195x960x680 195x960x680
24.0 25.013.0 / 10.0 13.0 / 10.013.0 / 10.0 13.0 / 10.053.0 / 48.0 54.0 / 49.053.0 / 48.0 54.0 / 49.037.0 / 32.0 38.0 / 33.037.0 / 32.0 38.0 / 33.0
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
550x765x285 735x825x30034 48
-10~46 -10~46-15~20 -15~20
63 6144 4445 4548 4848 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz6.35 / 9.52 / 18 6.35 / 12.7 / 18
20 30
FHQ-B / RXS-G
91
RXS35GFHQ-B BRC1D52 BRC7E66
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ60BVV1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
Heating capacity Minimum kW
Standard kW
Maximum kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label Cooling / Heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RXS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
heat pump 2 steps optional
optional optional optional
1.75.7
6.0
1.7
7.2
8.0
2.65 / 2.89
1075
D / D195x1160x680
27.017.0 / 13.016.0 / 13.055.0 / 49.055.0 / 49.039.0 / 33.039.0 / 33.0
R-410A1~/220-240V/50Hz
735x825x30048
-10~46-15~18
63494946
R-410A1~/220-240/220-230V/50Hz
6.35 / 12.7 / 1830
FHQ-B / RXS-F
92
RXS60FFHQ60B BRC1D52 BRC7E63
60
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional optional 2 steps optional
optional
7.1 7.1 9.8 9.8 12.2
8.0 8.0 11.2 11.2 14.5
2.63 / 2.81 2.68 / 2.86 2.61 / 2.71 2.66 / 2.79 2.71 / 2.81
1350 1325 1875 1840 2255
D / D D / D D / E D / E D / D
195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0
17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32084 83 103 101 108
-5.0~46.0-10.0~15.0
63.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FHQ-B / RQ-B
93
RQ100BFHQ71B BRC1D52 BRC7E63
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m* Combination only available in Portugal, Greece, Cyprus and Malta
optional heat pump 2 steps optional
optional
optional
7.1 7.1 9.8 9.8 12.2
8 8 11.2 11.2 14.5
2.63 / 2.81 2.68 / 2.86 2.61 / 2.71 2.66 / 2.79 2.71 / 2.81
1350 1325 1875 1840 2255
D / D D / D D / E D / E D / D
195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0
17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32083 102 100 108
10.0~46.0-10~15
65.0 70.053.0 57.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26500.5
FHQ-B / REQ-B*
94
FHQ71B BRC1D52 BRC7E66 REQ71B
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump 2 steps
optional
optional optionaloptional
7.1 10.0 12.5
8.0 11.2 14.0
2.81 / 2.81 2.41 / 2.81 2.73 / 2.82
1,265 2,075 2,290
C / D E / D D / D
195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0
17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 700x900x320 1,170x900x32068 103
-5~46-15~15.5
65 6749 5151 55 5347 49
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2630 50
0.5
FHQ-B / RZQS-C
95
RZQS100,125CFHQ71B BRC1D52 BRC7E63
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump 2 steps
optional
optional optionaloptional
7.1 10.0 12.5
8.0 11.2 14.0
2.89 / 3.00 3.03 / 3.21 2.81 / 3.21
1,230 1650 2225
C / D B / C C / C
195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0
17.0 / 14.0 24.0 / 20.0 30.0 / 25.017.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32067 103
-15.0~50.0-20.0~15.5
63 65 6647 49 5049 51 5243 45
R-410A1~/220-240V/50Hz
9.52 / 15.9 / 2650 75
0.5
FHQ-B / RZQ-C
96
BRC1D52 BRC7E63 FHQ71B RZQ100,125C
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
HEAT PUMP INVERTERIndoor UnitsIndoor Units FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/min
Heating High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBA
Heating High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ100B8W1B RZQ125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBASound Level (Night quiet) Sound Pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
heat pump 2 steps
optional
optional optionaloptional
10.00 12.50
11.20 14.00
3.17 / 3.11 2.81 / 3.11
1575 2225
B / D C / D
195x1400x680 195x1590x68032.0 35.0
24.0 / 20.0 30.0 / 25.024.0 / 20.0 30.0 / 25.058.0 / 53.0 60.0 / 55.058.0 / 53.0 60.0 / 55.042.0 / 37.0 44.0 / 39.042.0 / 37.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
1345x900x320106
-15.0~50.0-20.0~15.5
65.0 66.049.0 50.051.0 52.0
45.0R-410A
3N~/400V/50Hz9.52 / 15.9 / 26
750.5
FHQ-B / RZQ-BW1
97
RZQ100,125BFHQ-B BRC1D52 BRC7E63
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
COOLING ONLY INVERTERIndoor UnitsIndoor Units FHQ35BVV1B FHQ50BVV1B Capacity Cooling capacity Minimum kW
Standard kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label coolingDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS35G2V1B RKS50G2V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Low) Cooling dBASound Pressure (High) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
2 steps
optional
35~60 optional optional
optional
1.4 1.73.4 5.03.7 5.6
3.24 2.73
525 915
A D195x960x680 195x960x680
24.0 25.013.0 / 10.0 13.0 / 10.053.0 / 48.0 54.0 / 49.053.0 / 48.0 54.0 / 49.037.0 / 32.0 38.0 / 33.0
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
550x765x285 735x825x30034 48
-10~46 -10~4662 6144 4448 48
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 9.52 / 18 6.35 / 12.7 / 1820 30
FHQ-B / RKS-G
98
FHQ-B BRC1D52 BRC7E66 RKS35G
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
COOLING ONLY INVERTERIndoor UnitsIndoor Units FHQ60BVV1BCapacity Cooling capacity Minimum kW
Standard kW
Maximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RKS60F2V1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional 2 steps optional
standard optional
1.75.7
6.0
2.65
1075
D195x1160x680
27.017.0 / 13.055.0 / 49.055.0 / 49.039.0 / 33.0
R-410A1~/220-240V/50Hz
735x825x30047
-10~4663
49(H) - 46(SL)R-410A
1~/220-240V/50Hz6.35 / 12.7 / 18
30
FHQ-B / RKS-F
99
RKS60FFHQ60B BRC1D52 BRC7E66
60
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FHQ50BVV1B FHQ60BVV1B Nominal Capacity Cooling capacity Standard kW
Minimum kWMaximum kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RN50E3V1B RN60E3V1B Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional 2 steps optional
standard optional
5.0 5.7
- -- -
2.73 2.73
915 1075
D D
195x960x680 195x1160x68025.0 27.0
13.0 / 10.0 17.0 / 13.054.0 / 49.0 55.0 / 49.054.0 / 49.0 55.0 / 49.038.0 / 33.0 39.0 / 33.0
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
735x825x300 735x825x30047 47
-10.0~46.0 -10.0~46.061.0 63.047.0 49.0
R-410A R-410A1~/220-240V/50Hz 1~/220-240V/50Hz
6.35 / 12.7 / 18 6.35 / 12.7 / 1830 3020 20
FHQ-B / RN-E
100
RN50,60EFHQ50B BRC1D52 BRC7E66
50~60
Ceiling Suspended Unit
Ideal solution for shops, restaurants or offi ces without false ceilings
Compact design Leaves maximum fl oor and wall space for
furniture, decorations and fi ttings Easy installation and maintenance Auto-swing function ensures effi cient air and
temperature distribution. Air fl ow distribution for ceiling heights up to 3.8m
without loss of capacity.
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1BCapacity Cooling capacity Standard kW
EER Nominal
Annual energy consumption kWh
Energy Label cooling
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling High/Low m³/minSound Power Cooling High/Low dBA
Heating High/Low dBASound Pressure Cooling High/Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) mMax. internunit level difference m
optional 2 steps optional
optional
standard
7.10 7.10 9.80 9.80 12.20
2.63 2.68 2.61 2.66 2.71
1350 1325 1875 1840 2255
D D D
195x1160x680 195x1400x680 195x1590x68027.0 32.0 35.0
17.0 / 14.0 24.0 / 20.0 30.0 / 25.055.0 / 51.0 58.0 / 53.0 60.0 / 55.055.0 / 51.0 58.0 / 53.0 60.0 / 55.039.0 / 35.0 42.0 / 37.0 44.0 / 39.0
R-410A1~/220-240V/50Hz
770x900x320 1170x900x32083 81 102 99 106
-15.0~46.063.0 66.0 67.050.0 53.0
R-410A1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz
9.52 / 15.9 / 26700.5
FHQ-B / RR-B
101
RR100BFHQ71B BRC1D52 BRC7E66
102
103
PACKAGED SYSTEMSFDQ-B / RZQ-C 104FDYP-B / RYP-B 105FDYP-B / RP-B 106
ROOF TOP UNITSUATYP-A 108UATP-A 109
A range of high performance, low energy consumption air
cooled packaged roof top units is produced by Daikin for
supermarket, warehouse, factory, hotel, hospital, cinema and
large store applications.
Heat pump and cooling only ‘plug and play’ versions are
easy to install and available as fully integrated systems
comprising compressor, evaporator and condensing units for
air transmission through ductwork to the conditioned space.
Roof Top & Packaged Systems
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only
the suction and discharge grilles are visible Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
HEAT PUMP INVERTERIndoor UnitsIndoor Units FDQ200B8V3B9 FDQ250B8V3B9Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / Heating
Annual energy consumption kWh
Energy Label cooling / heating
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling Medium dBASound Pressure Cooling High dBA
Heating Low dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RZQ200C7Y1B RZQ250C7Y1BDimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound power dBASound pressure dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas mmPiping Length (Maximum) m
heat pump
optional
2 steps: FDQ250, 3 steps: FDQ200
optional
standard
20.0 24.1
23.0 26.4
3.21 / 3.41 2.81 / 3.21
3.115 4.290A / B C / C
450x1400x90089.0 94.069.0 89.069.0 89.081.0 82.045.0 47.045.0 47.0
R-410A1~/230V/50Hz
1680x930x765183 184
-5.0~46.0-15.0~15.0
7857
R-410A3N~/380-415V/50Hz
9.5 / 22,2100
FDQ-B / RZQ-CY1
104
RZQ200,250CFDQ200,250BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
HEAT PUMP NON-INVERTERIndoor UnitsIndoor Units FDYP200B8V19 FDYP250B8V19Capacity Cooling capacity Standard kW
Heating capacity Standard kW
EER / COP Cooling / HeatingAnnual energy consumption kWhDimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High dBA
Heating High dBARefrigerant TypePower Supply
Outdoor UnitOutdoor Unit RYP200B7W1 RYP250B7W1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDB
Heating Min~Max °CWBSound Power Cooling dBASound Pressure (Standard) Cooling dBA
Heating dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
2 steps: FDYP250, 3 steps: FDYP125-200
twin application only
heat pump
optional
19.50 25.00
23.10 27.00
2.24/3.04 2.45/3.084,345 5,100
450x1400x90089.0 94.069.0 89.069.0 89.081.0 82.081.0 82.045.0 47.045.0 47.0
R-407C230V/50Hz
1220x1290x700 1440x1290x700196 210
-5~46-10~15
77.057.057.0
R-407C400V/50Hz
12.7 / 28.6 / 26 15.9 / 28.6 / 2650
FDYP-B / RYP-B
105
RYP250BFDYP200,250BBRC1D52
Concealed Ceiling Unit
Slim design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor Maximum external static pressure (ESP) ranges
from 150 till 250Pa Optimum air distribution
COOLING ONLY NON-INVERTERIndoor UnitsIndoor Units FDYP200B8V19 FDYP250B8V19Capacity Cooling capacity Standard kW
EER Nominal
COP Nominal
EER / COP Cooling / Heating
Annual energy consumption kWh
Dimensions (Height x Width x Depth) mmWeight kgAir Flow Rate Cooling Medium m³/min
Heating Medium m³/minSound Power Cooling High dBA
Heating High dBASound Pressure Cooling High dBA
Heating High dBARefrigerant Type
Power Supply
Outdoor UnitOutdoor Unit RP250B7W1 RP200B7W1Dimensions (Height x Width x Depth) mmWeight kgOperation Range Cooling Min~Max °CDBSound Power Cooling dBASound Pressure (Standard) Cooling dBARefrigerant TypePower SupplyPiping connections Liquid (OD)/Gas/Drain mmPiping Length (Maximum) m
optional
2 steps: FDYP250, 3 steps: FDYP125-200
twin application only
optional
20.00 25.00
2.30 2.33- -- -
4,355 5,370450x1400x900
89.0 94.069.0 89.069.0 89.081.0 82.081.0 82.045.0 47.045.0 47.0
R-407C
230V/50Hz
1220x1290x700 1440x1290x700194 206
-5~4677.056.0
R-407C400V/50Hz
12.7 / 28.6 / 26 15.9 / 28.6 / 2650
FDYP-B / RP-B
106
RP250BFDYP200,250BBRC1D52
107
Rooftop
‘Plug and Play’ installation: the single unit confi guration requires no additional piping work as both the indoor and outdoor sides are pre-connected.
Refrigerant is factory pre-charged to ensure clean and effi cient operation.
The air volume and static pressure required can be adjusted according to the requirement because of the use of a belt driven fan.
The fl at top design of the unit allows for maximum utilization of warehouse and container space.
High effi ciency and reliable scroll compressor. Convertible: fan can be mounted in two directions
(Class 240-280-320-450-560). Coil with anti-corrosion treatment.
HEAT PUMP NON-INVERTEROutdoor UnitsOutdoor Units UATYP180AMY1 UATYP240AMY1 UATYP280AMY1 UATYP320AMY1 UATYP450AMY1 UATYP560AMY1 UATYP700AMY1 UATYP850AMY1 UATYPC10AMY1 UATYPC12AMY1Capacity Cooling Minimum kW 16.705 21.101 25.790 29.307 43.668 55.684 67.406 82.939 101.110 109.609
Heating Nominal kW 20.222 22.566 29.89 35.755 46.891 67.406 74.733 92.317 102.290 126.314EER Cooling 2.44 2.51 2.38 2.28 2.64 2.63 2.31 2.17 2.34 2.27COP Heating 3.06 2.99 3.05 3.11 2.98 3.32 2.85 2.65 2.45 2.70Air Flow Rate evaporator Cooling m³/min 51 80 100 102 160 190 226 263 312 354External Static Pressure Pa 98 196 294Condensation Drain Size Diameter (OD) mm 25.4
Casing Colour Light GreyMaterial Electro galvanised mild steel
Dimensions Unit HxWxD mm 1000x1100x1530 1200x1990x1800 1735x2250x2800 1974x2252x3180Weight Unit kg 320 385 415 440 700 800 12000 1350 1510 1600Air Flow Rate condensor Cooling m³/min 127 160 283 320 566Operation Range Cooling Min-Max °CDB 20°C – 46°C
Heating Min-Max °CWD -15°C – 20°CSound Level Sound Power dBA 63 65 66 68 70 70 74 74 80 80Refrigerant Type R-407CPower Supply 3~/50Hz/380-415V
108
UATYP-A
UATYP-A
Rooftop
‘Plug and Play’ installation: the single unit confi guration requires no additional piping work as both the indoor and outdoor sides are pre-connected.
Refrigerant is factory pre-charged to ensure clean and effi cient operation.
The air volume and static pressure required can be adjusted according to the requirement because of the use of a belt driven fan.
The fl at top design of the unit allows for maximum utilization of warehouse and container space.
High effi ciency and reliable scroll compressor. Convertible: fan can be mounted in two directions
(Class 240-280-320-450-560). Coil with anti-corrosion treatment.
COOLING ONLY NON-INVERTEROutdoor UnitsOutdoor Units UATP180AMY1 UATP240AMY1 UATP280AMY1 UATP320AMY1 UATP450AMY1 UATP560AMY1 UATP700AMY1 UATP850AMY1 UATPC10AMY1 UATPC12AMY1Capacity Cooling Minimum kW 17.291 21.101 27.842 32.238 41.030 55.684 67.406 82.939 97.007 121.624
Nominal kW 5.89 8.70 11.60 12.18 17.20 25.10 28.70 40.16 41.87 48.80EER Cooling 2.94 2.43 2.40 2.65 2.39 2.22 2.35 2.07 2.32 2.49Air Flow Rate evaporator Cooling m³/min 51 80 100 102 160 190 227 263 312 354External Static Pressure Pa 98 196 294Condensation Drain Size Diameter mm 25.4Casing Colour Light Grey
Material Electro galvanised mild steelDimensions HxWxD mm 1000x1100x1530 1000x1300x1530 1200x1990x1670 1735x2250x2800 1974x2252x3180Weight Unit kg 295 370 400 425 665 765 1200 1350 1510 1600Air Flow Rate condensor Cooling m³/min 127 160 227 320 566Operation Range Cooling Min-Max °CDB 20°C - 46°CSound Level Sound Power dBA 63 65 66 68 70 70 74 74 80 80Refrigerant Type R-407CPower Supply 3~/50Hz/380-415V
109
UATP-A
UATP-A