GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project...

39
PREPARED FOR CEA GROUP 4712 WOODROW BEAN, SUITE F EL PASO, TEXAS 79924 GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION REPORT FOR EPW SAN LORENZO DRAINAGE IMPROVEMENTS PROJECT CARL LONGUEMARE ROAD TO SOUTHSIDE ROAD EL PASO, EL PASO COUNTY, TEXAS CQC PROJECT NO. AGCQC19-037 CQC TESTING AND ENGINEERING, L.L.C. TBPE FIRM REGISTRATION NO. F-10632 4606 Titanic Ave. EL PASO, TEXAS 79904 PH.: (915-771-7766 FX.: (915) 771-7786 DBE & HUB Certified Local El Paso, Texas Firm

Transcript of GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project...

Page 1: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

PREPARED FOR

CEA GROUP 4712 WOODROW BEAN, SUITE F

EL PASO, TEXAS 79924

GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION REPORT

FOR

EPW – SAN LORENZO DRAINAGE IMPROVEMENTS PROJECT

CARL LONGUEMARE ROAD TO SOUTHSIDE ROAD

EL PASO, EL PASO COUNTY, TEXAS

CQC PROJECT NO. AGCQC19-037

CQC TESTING AND ENGINEERING, L.L.C. TBPE FIRM REGISTRATION NO. F-10632 4606 Titanic Ave. EL PASO, TEXAS 79904 PH.: (915-771-7766 FX.: (915) 771-7786

DBE & HUB Certified Local El Paso, Texas Firm

Page 2: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration
Page 3: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 1 of 21

Report Table of Contents

Page No.

Section 1.0 – General Project Information 3 1.1 Site Geologic Considerations 3 1.2 Existing Site Topography and Vegetation 4 1.3 Seismic Considerations 4 Section 2.0 – General Subsurface Soils Evaluation 5 2.1 Observed Existing Pavement Material Thicknesses 6 2.2 Laboratory Engineering Soil Classification Testing 6 2.3 Soil Moisture-Density Relationship Test Results 7 2.4 Soil California Bearing Ratio (CBR) Test Results 7 2.5 pH Test Results 8 2.6 Laboratory Soil Resistivity Test Results 8 Section 3.0 – Encountered Subsurface Soil Conditions 9 3.1 Groundwater Depth Considerations 10 3.2 Subsurface Soil Considerations and Preparation 11 - Special Considerations

- Site Preparation 3.3 Drainage Considerations 12 Section 4.0 – Soil Bearing Capacity and Design Considerations 12 4.1 Sewer Line Replacement Design Considerations 12 4.2 Earth and Vehicle Loads 12 Section 5.0 – Below Grade Lateral Earth Pressures 13 Section 6.0 – General Trench Safety Considerations 14 6.1 Trench Safety Considerations 14 Section 7.0 – Pipe Embedment and Backfill Considerations 16 Section 8.0 - Pavement Replacement Recommendations 17

Section 9.0 – Additional Design and Construction Considerations 17

Section 10.0 – Project Specification Information 18 10.1 Fill Materials 18 10.2 Construction Materials Testing 20 Section 11.0 – Soils Evaluation Considerations and Limitations 21

Page 4: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 2 of 21

List of Appendices

Appendix A Sheet No. General Geotechnical Subsurface Exploration Boring Location Aerial Plan A1-1 City of El Paso Flood Zone Aerial Plan A1-2 Vertical Exploration Boring Logs A2-A3 Particle Size Analysis Test Reports A4-A5

Summary of Field & Laboratory Test Results A6 Moisture-Density Relationship Test Results A7 California Bearing Ratio Test Results A8 Soil Resistivity Test Results A9

Appendix B Geotechnical Report Technical Reference Information B1 Soil Classification Chart B2 Geotechnical Report Soil Classification Reference Information B3

Page 5: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 3 of 21

Section 1.0 – General Project Information

This general geotechnical subsurface soils evaluation report has been prepared for CEA Group

(Client) for the El Paso Water – San Lorenzo Drainage Improvements Project. The project consist of the

replacement of an 18-inch CMP storm sewer line with RCP or ADS Sanitite storm sewer pipe along San

Lorenzo Avenue from Carl Longuemare Road to Southside Road located in east El Paso, El Paso County,

Texas. We understand that the new pipeline invert depth shall be approximately 6 feet below the existing

asphaltic-concrete pavement surface elevations.

Our specific scope of services for this project consisted of generally evaluating the subsurface soil

conditions along the proposed new storm sewer line alignment route by collecting subsurface soils

information, conducting Standard Penetration Tests (SPT’s), and preparing soil related information with

respect to the suitability of the on-site soils, engineering soil classifications, bearing resistance, and

potential construction use for pipeline backfilling.

The following sections of this report present our field evaluation methods, site soil-related

considerations, estimated allowable bearing capacity values, and guidance information with respect to site

preparation, pipeline embedment, soil backfilling, and trench safety considerations. Please note that the

entire report should be read for a thorough understanding of our evaluation, findings, and guideline

recommendations. CQC Testing and Engineering, L.L.C. (CQC) should be contacted through a written

statement if our stated understanding of the project is not correct and/or if the owner changes the proposed

sewer line route for this project. Pipeline route changes may result in our information and recommendations

within this report to be invalid without further review and evaluation by CQC.

1.1 - Site Geologic Considerations

The Geologic Atlas of Texas (Van Horn-El Paso Sheet, Revised 1995) published by the Bureau of

Economic Geology at the University of Texas at Austin indicates that that the project site is located in an

area of Young Quaternary (Qb) and Windblown sand (Qws) deposits which typically consist of lacustrine,

fluviatile and areas of large dunes. Soil deposits such as clay, silt, sand, gypsum and caliche are typically

encountered within these geologic formations. These deposits are usually variable over relatively short

distances.

Based on the City of El Paso floodplain maps, a portion of the project limits is located within a

floodplain area. This should be verified by the project civil engineer. The Flood Zone Map can be found in

Sheet A1-2 for ease of reference. Please note that the indicated flood plain paths on the exhibit may not

Page 6: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 4 of 21

represent the exact flood plain path locations and shall vary. This shall be further evaluated with a

topographic survey and drainage analysis.

According to registered wells (No. 78-46-97) found on the Texas Commission on Environmental

Quality (TCEQ) website, the water level ranges from 14 to 17 feet below the existing surface elevation.

These readings were observed between 2001 and 2003.

It has been reported that no significant ground movement caused by the existing faults has been

recorded for the past 50 years in the El Paso area. Although the local seismic observatory at the University

of Texas at El Paso (UTEP) has indicated that the frequency of recordable ground movements has

increased within the last decade.

Please note that our scope of work did not include the specific delineation of faults within the project

construction limits and/or the development of specific design recommendations over faults zones.

However, these services may be provided as an additional scope of work and service to our Client, if

required.

1.2 – Existing Site Topography and Vegetation

Based on general site observations, the area within the project limits appears to be relatively level.

The proposed pipeline route is within a residential development and the street is paved with a flexible

pavement structure. In general, the adjacent properties to the pipeline construction are single and two-

story residential buildings. South Loop Elementary School Campus and the PanAmerican Drive Industrial

Park are in the vicinity of the project area.

CQC was not provided any historical or current topographic survey plans, design plans,

construction reports or environmental reports for review from our Client. Therefore, CQC has no

knowledge if previous site excavations or fill was appropriately backfilled with suitable soils and tested for

compaction verification.

1.3 – Seismic Considerations

Based on our review of the current International Building Code and Site Classification for Seismic

Design Definitions in conjunction with our review of the geologic conditions in the area, it is our professional

opinion that a Site Class D may be considered for this project. Please note that a geologic atlas of the

area was used to supplement our analysis since our borings were performed to maximum depth of 10 feet

below the existing ground surface elevation and the building code considers the average soil properties in

the top 100 feet of the subject site. In the event that the owner and/or design representative is interested

Page 7: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 5 of 21

in determining the building code Site Class with a higher degree of accuracy, additional tests beyond our

original requested scope of work shall be required.

Based on a Soil Site Class D, seismic ground motion values were estimated based on a latitude

and longitude coordinate at the general center area of the project limits as defined in the table below. The

seismic coefficients were generated through the SEAOC/OSHPD Seismic Design Maps website. The

values should be verified by the project structural engineer prior to use in structural analysis. CQC should

be informed if the reported values vary significantly.

Table 1 – Seismic Ground Motion Values

Borehole No. Latitude Longitude

(-) Period

(Seconds)

Spectral Accelerations

(g)

Site Coefficient

Fa

Site Coefficient

Fv

B-1 and B-2 31.682113 106.322969 0.2 (Ss) 0.339 1.535 -

1.0 (S1) 0.161 - 2.397

Section 2.0 – General Subsurface Soils Evaluation

As requested by our Client, the subsurface soils along the proposed pipeline alignment were

evaluated by completing a total of two (2) vertical subsurface exploration borings performed at the

approximate locations shown in the General Geotechnical Subsurface Exploration Boring Location Aerial

Plan, Sheet A1-1 in this report.

The vertical exploration borings were drilled with a rotary drilling rig (CME-75) and hollow stem

auger drilling techniques and were logged during our field operations by a member of our geotechnical

engineering staff. Our boring logs are presented in Sheets A-2 and A-3. In general, the borings were drilled

to a maximum depth of 10 feet, each below the existing flexible pavement elevation. During our drilling

operations Standard Penetration Tests (SPT’s) were performed in general conformance with ASTM D

1586. Soil samples were collected within a split-spoon sampler at discrete depth intervals and were

containerized and transported to our laboratory for further observation and engineering soil classification

testing. Our laboratory engineering soil classification tests (i.e., moisture contents, sieve analysis, and

Atterberg Limit Tests) were performed in accordance with accepted ASTM test procedures D 2216, D

1140, D 2217, D6913, and D 4318, respectively. In general, the results of our tests and estimated “N-

Values” are presented in our boring logs and Summary of Laboratory Engineering Soil Classification Test

Results in Sheet A6. At the completion of our subsurface exploration activities, the borings were backfilled

with soil cuttings, firmly compacted and patched with concrete at the ground surface.

The following table summarizes the completion depth of our borings, type of samples, and number

of collected samples at the time of our subsurface exploration activities.

Page 8: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 6 of 21

Table 2 – Summary of Field Evaluation – Boring Depths & Samples Collected

Summary of Subsurface Exploration Evaluation

Borehole No. Approximate Termination

Depth (ft.)

No. Split-Spoon

Samples

No. Grab Samples

Observed

Groundwater / Water Seepage

Depth (ft.)

B-1 10 4 -- NE

B-2 10 4 -- NE

NE- Not encountered in our vertical borings at the completion of our drilling activities.

Contractors interested in bidding the project shall perform their own tests to verify the types of

materials or review historical plans of the area to evaluate the excavation requirements prior to bidding the

project. The owner shall not incur additional costs for additional excavations or removal of encountered

variable unclassified soils, sloughing soils experienced during excavations, buried materials or utilities.

Please note that the collected soil samples from our soils evaluation shall be stored for a period of

up to 60 days after the submittal of this report, if a longer period of storage is required by our client, CQC

should be informed in writing.

2.1 - Observed Existing Pavement Material Thicknesses

Based on our observations at the time of our drilling activities, the encountered pavement section

along San Lorenzo Avenue contains approximately 3 inches of asphaltic-concrete pavement and

approximately 4 to 5 inches of apparent base course material. The results are summarized in the following

Table.

Table 3. Summary of Asphaltic Concrete Pavement Cores

Core No.

Core Approx. Average Measured Thickness

Base Course Approx. Average Measured

Thickness

C-1 3 in. 5 in.

C-2 3 in. 4 in.

Please note that it should be considered that the reported encountered asphaltic-concrete layer

and base course material thickness shall vary along the pipeline route.

2.2 - Laboratory Engineering Soil Classification Testing

In the laboratory, selected soil samples were evaluated and visually classified by our geotechnical

engineering staff in general accordance with the Unified Soil Classification System (USCS). The

geotechnical engineering properties of the selected samples were evaluated by the following tests.

Page 9: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 7 of 21

Table 4 – Summary of Performed Laboratory Engineering Classification Tests

Type of Test

Total Number Conducted

Soil Moisture Contents 6

Atterberg Limit Tests 2

Particle Size Analysis Tests 6

Moisture-Density Relationship Tests 1

California Bearing Ratio (CBR) Tests 1

Our selected particle size sieve analysis test results are reported in Sheets A4 and A5 in this report.

A summary of our laboratory engineering soil classification test results is reported in Sheet A6 for ease of

reference.

2.3 – Soil Moisture-Density Relationship Test Results

At the time of our drilling activities, a single (1) bulk soil sample was obtained from boring location

B-1 for soil moisture-density relationship testing. The sample was collected during our drilling activities

from auger cuttings from approximately below existing pavement surface to about 3 feet. The test results

are reported in Sheet A7. A summary of the results are presented in the table below.

Table 5 – Summary of Soil Moisture-Density Relationship Test Results

Borehole No.

Approx. Sample

Depth (ft)

ASTM D 1557,

Method Soil Classification*

Plasticity Index

Opt. Dry Density

(pcf)

Opt. Moisture

(%)

B-1 1 – 3 B CL 23 111.3 15.4

Note: *Soil description is reported in our test results in Sheet A7.

2.4 – Soil California Bearing Ratio (CBR) Test Results

The results of a single (1) California Bearing Ratio (CBR) test conducted on a collected bulk soil

sample from boring location B-1 is presented in the table below and Sheet A8. The test was performed in

general accordance with ASTM standard test method D-1883. Based on our CBR test results, the soils at

the sample location shall provide a relatively low level of support for the new replacement pavement section

along pipeline trench. We anticipate that the pipeline trench shall be backfilled with Select Fill soils.

Table 6 – Summary of California Bearing Ratio (CBR) Test Results

Borehole No.

Sample Depth (ft)

Dry Density prior to Soaking

(pcf)

Dry Density

after Soaking

(pcf)

Swell % CBR at

0.1” Pen. CBR at

0.2” Pen. Support

Level

B-1 1 - 3 106.6 89.0 9.9556 1 1 Low

Page 10: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 8 of 21

The soil swell test results also indicate that the encountered fat clays in boring B-1 exhibit a high

potential for swelling when saturated with moisture.

2.5 – pH Test Results

Corrosion is the disintegration of a material due to chemical reactions with its surroundings. Any

contact between the soil material and any concrete structures, steel piles, or metal appurtenances could

result in corrosive reactions. In order to evaluate the potential corrosivity of the subsurface soils, pH tests

are typically performed on soil samples. A composite soil sample from our soil borings was tested in the

laboratory for pH content in accordance with TEX-128-E. The results of this test are presented in the table

below.

Table 7 – Summary of Soil pH Test Results

Borehole No. Sample Depth

(ft) pH

Composite of B-1 and B-2

5 8.7

Soils with a pH ranging from 5 to 9 are generally not considered to affect corrosion rates. However,

soils with a pH of 4 or less represent a serious corrosion risk to common construction materials.

2.6 - Laboratory Soil Resistivity Test Results

The subsurface soils from the exploration borings were analyzed by performing a laboratory soil

resistivity test using the soil box method per TxDOT Designation: TEX-129-E. This test is conducted by

using a portable resistivity meter and a small acrylic box with inside dimensions of 8½ in. x 1½ in. x 1¼ in.

The resistivity values obtained may represent the resistivity of the tested soil sample. The test consists of

adding moisture to the soil in the box until the lowest resistance reading before an increase is noted. This

reading is used to calculate the resistivity of the soil using the soil box factor. In general, tests were

performed on soil samples collected at depths from about 5 to 10 feet below existing pavement surface

elevations from borings B-1 and B-2. The soil resistivity test results along with a graphical plot are

presented in Sheet A9. Based on the results from a composite sample that aid in better defining the

corrosion properties of subsurface soils, the tested subsurface soils may be considered corrosive at a very

moist to saturated states, particularly for steel casings (See Table 7).

We anticipate that the new pipe shall be surrounded by suitable backfill soil materials, however, we

recommend that in order to mitigate potential steel corrosion, Type II Portland cement should be utilized

in concrete mix designs for this project or per manufacturer requirements, as applicable. The specification

of cathodic protection should be considered, as applicable.

Page 11: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 9 of 21

Table 8 – Corrosivity Ratings Based on Soil Resistivity

Soil Resistivity (ohm-cm)

Corrosivity Rating

> 20,000 Non-Corrosive

10,000 to 20,000 Mildly Corrosive

5,000 to 10,000 Moderately Corrosive

3,000 to 5,000 Corrosive

1,000 to 3,000 Highly Corrosive

< 1,000 Extremely Corrosive

Section 3.0 – Encountered Subsurface Soil Conditions

Based on our soil classifications and laboratory tests, the subsurface soils encountered in our

exploration borings may be described by four (4) generalized soil stratums. In order to gain access to the

subsurface soils at each boring location, we cored thru an existing 3 inches thick asphaltic concrete

pavement over 4 to 5 inches of apparent base course material. The logged depths of the reported soil

formation types are approximately delineated in our exploration vertical boring logs. The proposed pipeline

route is located in the Lower Valley area, as a result it shall be expected for variations in the subsurface

soil formations to occur over relatively short distances.

Table 9 – Summary of Subsurface Soil Classification & Strength

Type General

Description

Relative Density / Consistency

(SPT Blow Counts)

Moisture Content (%)

Atterberg Limits %Passing

No. 200 USCS

Classification Plastic Limit

Plasticity Index

I

Fine to Medium Grained

Loose (9) 9.0 Non- Plastic 47 SM

Remarks: These type of soil formations were encountered in Borings B-2 at a depth of about 5 feet. These

sands shall be susceptible to soil sloughing during excavations. These soil formations may be considered Class III Pipe Backfill soil materials.

II

Fine to Medium Grained

occasionally intermixed with

silt

Loose (7 to 9)

2.0 to 7.0 Non-Plastic 2 to 8 SP or SP-SM

Remarks: These type of formations were encountered in boring B-1 and B-2 at depths ranging from 2-1/2 feet to about 10 feet. These poorly graded sand shall be susceptible to soil sloughing during excavations. These soil formations may be considered Class III Pipe Backfill soil materials.

III

Lean Silts with some sand

Soft (7)

10.0 to 21.0 30 7 55 to 90 ML

Remarks: These silt soils were encountered in boring B-2 primarily within the upper five (5) feet. These soils shall be removed and replaced with approved Select Fill soil materials. These soils may be considered Class IV Pipe Backfill soils materials.

IV High Plasticity Fat Clays with

some sand

Stiff (17)

36.0

78

57

95

CH

Page 12: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 10 of 21

Remarks: These fat clays were encountered in boring B-1 within the upper three (3) feet. These clays are

not considered suitable for use as approved Select Fill and Backfill soil materials. Clays shall be removed and replaced with suitable approved backfill soil materials. These clayey soils may be considered Class IV soils materials.

Based on our SPT data, the fat clays with soft consistency shall be susceptible to shrink and

swelling movements when exposed to variable moisture conditions. The sands encountered in a relatively

loose condition shall also be susceptible to elastic soil settlements when exposed to structure gross

bearing loads and saturated with moisture. In addition, we anticipate that the contractor may be required

to use trench box and/or rated shield systems to maintain excavation walls for the new pipeline stable.

The contractor shall be responsible for preparing a trench safety plan prior to construction for submittal to

the engineer for compliance with the project specifications.

3.1 - Groundwater Depth Considerations

At the time of our field operations, groundwater or water seepage was not observed or encountered

immediately at the completion of our exploratory borings. The groundwater depth in this area is anticipated

to be below an anticipated maximum excavation depth of 6 feet for this project. However, groundwater

elevations may fluctuate at different times of the year, particularly during precipitation and irrigation

seasons. As previously indicated, based on our review of information from registered wells between 2001

and 2003 (No. 78-46-97) found on the TCEQ website, the reported water levels ranged from 14 to 17 feet

below the existing surface elevation.

Please note that it is possible to encounter shallower perched water zones or water seepage where

relatively high permeability soils overlay low permeability soils. This is potentially true for this project area

since irrigation canals are in the vicinity of the project area. In the event that perched water is encountered

at shallower depths during construction excavation, the water seepage should be appropriately removed.

If an “artesian” condition is encountered it may be bridged with suitable Controlled Low Strength Materials

(CLSM) or approved gravel rock. The proposed CLSM or gravel rock should be approved by the engineer

of record through a submittal process. In any event, CQC should be immediately contacted to perform site

observations of the noted conditions to develop additional recommendations, if necessary. Workers shall

be prohibited from working in excavations where water has accumulated or is accumulating.

Our scope of work does not include the development of a dewatering plan or review of prepared

submittals by the general contractor, if required. CQC shall not be liable for observed structural distress of

adjacent structures within private properties near the project limits or within the project limits. It is the

Page 13: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 11 of 21

general contractor’s responsibility to consider these potential conditions in the preparation of a dewatering

plan and the establishment of a contingency to address noted structural distress and/or issued claims.

3.2 - Subsurface Soil Considerations and Preparation

The following section presents specific conditions that we have observed during our evaluation that

should be considered by the owner, design team and contractors interested in bidding the project with

respect to earthwork estimates and operations.

Special Considerations

Site work and backfilling should be performed in accordance with the following sections of this report or as required by the project specifications and plans, whichever is more stringent.

When placing backfill within utility line trenches or during the installation of the new pipelines, backfill materials should be appropriately placed and compacted to mitigate potential settlements caused by uncontrolled backfill during construction. The contractor should adequately over-excavate areas and backfill pipeline trenches with approved Select backfill soils, or as required by the project plans and specifications. Select Backfill material specifications are presented in Section 10.0 of this report.

Bidding general contractors shall be responsible for conducting their own tests to verify the actual depths of the soil and/or rock formations and types within the project limits to perform earthwork. The owner shall not incur additional costs for variations in the soil formations within the project limits and/or additional excavation requirements by the contractor. The boring logs in this report are intended for engineering design purposes. Bidding contractors may consider the information presented in this report at their own risk. If deemed necessary, bidding contractors shall perform additional borings and/or test pits for use and/or interpretation for earthwork estimates that comply with the project specifications prior to bidding.

Based on the encountered subsurface soil conditions and laboratory engineering soil classification test results, the soils encountered within the pipeline alignment should be considered Type “C” soils under current Occupational Safety and Health Administration (OSHA) regulations (Standard – 29 CFR-Part 1926.650, Subpart P- Excavations) pertaining to excavations. In excavations penetrating these soils, the non-permanent sloping and benching schemes specified for Type “C” soils under the OSHA regulations require that the excavation sidewalls be sloped no steeper than 1½:1 (horizontal: vertical) for Type “C” soils. Trenches or excavations 4 feet and deeper shall require the development of a trench safety plan to protect employees and the general public. Please note that it is the contractor’s responsibility to assign a “competent” person to perform daily inspections and required documentation in accordance with OSHA regulations. In addition, OSHA limits excavations to 20 feet when excavations utilize soil benching and sloping methods and braced/shored trench box (i.e., rated) shielded systems designed by a licensed professional engineer. Trench excavations utilizing sheet piling systems or un-braced temporary shielded systems per OSHA regulations shall be designed by a licensed professional engineer for any excavation depth in consideration to protect the health and safety of all workers and the public.

Based on our observations of the proposed pipeline alignment locations and access considerations, we anticipate that the contractor may be required to use rated braced trench box systems to install the replacement pipeline. As a result, the contractor shall be responsible for preparing a trench

Page 14: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 12 of 21

safety plan prior to construction with applicable manufacturer’s trench box system specifications for submittal to the engineer for compliance with the project specifications. The trench safety plan shall be performed by a licensed professional engineer. This report provides general trench safety considerations for the project under Section 6.0 below.

Site Preparation

The existing soils at this site that will support compacted Select Backfill materials and the proposed pipeline should be cleared of all vegetation, organic matter, construction/pavement debris and/or any foreign matter. The cleared subgrade should be thoroughly compacted in order to densify any weak and compressible zones. The finished subgrade and/or embedment soils should be compacted to a minimum of 90 percent of maximum dry density per ASTM D-1557 and maintained within ±3 percent of optimum moisture and/or as required by the project specifications, whichever is more stringent. Weak or compressible soil zones identified during fill operations should be reprocessed or over excavated, removed and replaced with specified compacted “Select Fill” to a minimum depth of 8 inches or as required to appropriately bridge over these soils, whichever is deeper. Subgrade preparation operations should be observed by a representative of CQC.

Approved suitable fill or backfill materials should be appropriately tested at standard frequencies as recommended in this report and/or as required by the project specifications, whichever is more stringent.

3.3 - Drainage Considerations

Drainage is an important key to the successful performance of any excavation and soil supported

structure. Positive surface drainage should be established prior to and be maintained during and after

construction to prevent water from ponding within or adjacent to the pipeline trenches. It is also possible

for sinkholes to be created if pipeline trenches are left open during periods of significant rainfall events

especially in sites that have significant vertical changes in elevation.

Section 4.0 – Soil Bearing Capacity and Design Considerations

4.1 – Storm Sewer Line Replacement Design Considerations

The encountered subsurface soils at the anticipated pipeline invert elevation of about 6 feet shall

provide an allowable bearing capacity of at least 1,500 pounds per square foot (psf). The recommendations in

the following sections of this report should also be considered in the design of the pipeline, associated

structures, pipeline embedment and backfilling.

4.2 - Earth and Vehicle Loads

The pipe analysis and design should consider the vehicular traffic loads, earth backfill loads, pipe

laying methods, bending stresses, potential for settlement, and estimated pipe deflections. The following

Page 15: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 13 of 21

soil related design parameters may be considered in the pipe design analysis. CQC should be contacted

if additional soil related information is required to supplement pipeline design and analysis.

Soil Related Design Parameters

-γs ≥ 120 pcf (Estimated Soil Total unit weight)

-Category II - Sandy & Fine Grained Soil Profile

- E’ = 500 psi (Presumptive Allowable Modulus of Soil Reaction for Clean Sand Backfill Bedding Soils)

Section 5.0 – Below Grade Lateral Earth Pressures

The proposed below grade structures and pipelines will be subjected to vertical and lateral earth

pressures depending upon the type of backfill soil. The table below presents at-rest (Ko) pressure

coefficients for select backfill soils. The Ko pressures are recommended for cases where the structures

will experience little yield and for relatively long term buried structures. Select backfill soils should meet

the requirements of Select Backfill or as required by the project specifications, whichever is more stringent.

Table 10. Earth Pressure Coefficients

Ranges for Earth Pressure Coefficients

Soil Type

Estimated Total Unit

Weight Ranges

(pcf)

Presumptive Soil Angle of Internal Friction Ranges

(, deg)

Lateral Earth Pressure

Coefficients

Lateral Earth Pressure

Coefficients

Equivalent Fluid

Weight (pcf)

Equivalent Fluid

Weight (pcf)

At-Rest (K o) Active (K a) At-Rest (K o) Active (K a)

Structural Fill – Base Course

145 - 148 39 - 42 0.37 – 0.33 0.22 – 0.20 54 - 48 32 – 30

Select Fill Soils (PI<12)

120 – 125 28 – 32 0.52 – 0.47 0.35 – 0.31 61 - 59 41 - 39

Silty Sands 128 – 130 30 – 34 0.50 – 0.44 0.33 – 0.28 64 - 56 42 – 36

Poorly Graded Sands

125 – 128 29 – 32 0.51 – 0.47 0.35 – 0.31 64 – 60 44 – 40

The lateral pressure with depth may be estimated with the following equation;

Ps = KoƔs (H-Hw ) + Ko(Ɣs -Ɣw )Hw + ƔwHw + q Ko

Where: Ps = lateral earth pressure at calculated depth, psf Ko = At-rest lateral earth pressure coefficient (typically used for long-term cases)

Ɣs = Total wet unit weight of soil, pcf H = Depth of structure from ground surface to calculated depth, ft Hw = Positive vertical downward depth of water from reported highest depth.

Page 16: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 14 of 21

Note when calculation depth is above reported water depth, then Hw term in equation is considered zero Ɣw = Unit weight of water, pcf

Where: q = Surcharge pressure, psf (typically only considered to 20 feet) light loads (i.e., pedestrians and soil stockpiles) – 50 psf,

moderate (i.e., light equipment) – 150 psf, heavy (i.e., heavy duty equipment) – 250 psf or more

Section 6.0 – General Trench Safety Considerations

The following report section presents general excavation trench safety considerations.

6.1 – Trench Safety Considerations

Trench excavations of more than 4 feet in depth and extending to a maximum depth of 20 feet may

be supported with rated shielded systems in accordance with OSHA regulations. Braced shielded

systems, such as trench boxes, should not be subjected to loads exceeding those which the system was

designed to withstand. Shields may be stacked, provided that they are installed in a manner to resist

lateral displacements or other hazardous movements of the shield in the event of sudden changes in lateral

loads, such as sidewall collapse, or impact from excavation equipment or any other potential force.

Employees shall not be allowed in shielded trenches when shields are being installed, removed, or

moved vertically or horizontally. Employees should not be permitted in trenches that show possible loss

of soil from behind or below the bottom of the shield. Hard hats and warning vests or other highly visible

Personal Protection Equipment (PPE) should be worn by all employees.

Surface encumbrances, such as boulders and vegetation, located so as to create a hazard to

employees involved in excavation work or in the vicinity thereof at any time during operations, shall be

removed, properly supported or made safe before excavation begins. Existing underground utility lines

shall be located prior to performing excavations and protected during excavation construction. Excavations

should not undermine existing structures and should be at least 10 feet from the toe of any structure.

When mobile equipment is operated adjacent to an excavation, a warning system should be utilized

such as barricades, hand or mechanical signals, or stop logs.

Properly designed means of access and egress from excavations should be provided for

employees. Structural members used as ramps and/or runways over excavations 6 feet or more in depth

should be equipped with guardrails and should be uniform in thickness and supported properly to prevent

displacements. Stairways, ladders, ramps, or other safe means of egress shall be located in trench

excavations that are 4 feet in depth or more in depth so as to require no more than 25 feet of lateral travel

for employees.

Page 17: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 15 of 21

A “competent person” shall inspect and document the excavation conditions trench systems and

equipment daily and notify the contractor's superintendent of any conditions which may adversely affect

the reliability and safety of the excavation. The excavations shall also be inspected after each rainstorm

or when any changes in conditions occur that can increase the possibility of a cave-in or slide. If evidence

of possible cave-ins or slides is apparent, all work in the excavation shall cease until the necessary

precautions for sloping or bracing have been taken to safeguard the employees and trench. Any loose soil

shall be scaled from the slope and removed from the excavation to protect workers against falling soil.

The atmosphere within a trench deeper than 4 feet shall be tested when there is a possibility of

oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or build-up of hazardous

gases. Ventilation should be provided to prevent flammable gas build-up to 20 percent of lower explosive

limit of the gas. In addition, testing should be conducted as often as necessary to ensure that the

atmosphere remains safe. Emergency rescue procedures and equipment should be readily available at all

times, especially where hazardous atmospheric conditions could exist or develop during work in an

excavation. Employees entering deep confined excavations should wear a safety harness with a lifeline

securely attached to the harness.

A health and safety plan and emergency rescue plan should be established and maintained by the

general contractor at all times during the project. In the event of an injury or emergency situation, it is

imperative to follow all guidelines as detailed in the most recent OSHA Standards for the Construction Industry

Manual, including completion of all necessary forms, accident procedures, and report documentation. After

rescue operations are implemented the accident area should be closed off and made safe until an OSHA

inspector visits the site and documents conditions after immediate notification. This emergency contact

information should be posted on the site at all times during excavation activities.

Excavations of earth material to a level not greater than 2 feet below the bottom of a shield may be

permitted, provided that the soil sidewalls are stable. Shields should extend to a minimum of 18 inches

above the top of the vertical side or crest of the excavation.

The trench box system should be used in accordance with the Manufacturer’s recommendations

in accordance with the requirements of a trench safety plan and current OSHA regulations. Excavation

safety systems for trenches shall be designed by a licensed professional engineer for all anticipated depths

for this project.

It shall be the contractor’s responsibility to document and record all daily excavation activities in

accordance with OSHA regulations. CQC and our Client shall have no liability for the selected means and

methods utilized by the contractor to perform excavations.

Page 18: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 16 of 21

Section 7.0 – Pipe Embedment and Backfill Considerations

Based on the results from our exploration borings and soil classification tests, the existing

subsurface soils are anticipated to consist of Class III and Class IV soil materials. Pipeline embedment

and backfill soil materials shall meet the specified requirements and/or the El Paso Water (EPW) standard

construction specifications for storm sewer pipelines. The encountered Class IV clays and silts The

following table presents general guidelines for backfill soil materials. Section 10.0 of this report presents

backfill soil material specifications. Pipeline backfill soil materials shall also meet the pipe manufacturer

requirements.

Table 11 - Pipeline Backfill Material Guidelines

BACKFILL ZONE BACKFILL MATERIAL

TYPE ASTM COMPACTION

REQUIREMENTS

Below Pipe Embedment Zone Class III or Select Fill 90% per ASTM D-1557

Embedment Pipe Zone

Class I, II or as specified by

pipe manufacturer 90% per ASTM D-1557

Trench Backfill Above Pipe Zone Class III or Select Fill 90% per ASTM D-1557

Backfill Material from Finished Surface to 36-inches

Class III or Select Fill 95% per ASTM D-1557

Additional Requirements: 1) The moisture content of the backfill materials shall be maintained within ±3% of optimum

moisture content or as specified. Pipe zone backfill material shall be maintained within +/- 2 %

optimum moisture content.

2) The supporting subgrade soils at the cut excavation that shall support embedment backfill material and the

pipes should be stripped of all vegetation, organic matter, clay soil lumps, topsoil, construction/pavement debris

and/or any foreign matter.

3) In general, embedment soil materials and pipes should not be directly supported by soils classified as CH, CL,

MH, ML, OH, OL and PT under the USCS in all cases.

4) Please note that the pipe zone is typically defined as the area extending from the bottom of the trench to 12

inches above the top of the pipe and extending to the undisturbed trench walls on both sides of the pipe.

5) The new storm sewer pipeline shall include the installation of manhole, junction boxes and inlet structures. We

recommend that these concrete structures be supported by a minimum of 8 inches of compacted Structural Fill

material, TXDOT Standard Specification 2014-Item 247, Type A, Grade 1-2. The Structural Fill shall be placed

in loose lifts not to exceed 4 inches to allow proper consolidation of the backfill material. The Structural Fill

should be compacted to at least 95 percent of the maximum dry density as per ASTM D 1557. The suitable

subgrade soils that shall support the base coarse material should be compacted to at least 95 percent of

Page 19: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 17 of 21

maximum dry density per ASTM D 1557. The moisture content of the subgrade soils shall be maintained within

±3 percent of optimum moisture content.

Section 8.0 – Pavement Replacement Considerations

We anticipate that the existing AC pavement section shall have to be replaced along pipeline open

cut trench areas. We recommend that the new Asphaltic-Concrete (AC) material conform to a TXDOT -

Item 341, Type C material with a minimum of 1,500 pounds of Marshall Stability (75 blows, ASTM D 1559),

a flow between 0.08 inches and 0.16 inches, air voids between 3 to 4 ½ percent, and should be placed at

a target of 96 to 98 percent of laboratory Marshall value. The asphalt content for the mix should be

determined based on the Marshall Mix Design method. The bitumen material should be a performance

grade material such as a PG64-22. We recommend that the specified replacement pavement section

consist of at least 3 inches of Type C - AC material underlie by a minimum of 6 inches of crushed stone

base course or a minimum of 12 inches of approved CLSM . The CLSM may consist of a soil-cement

stabilized backfill material. The CLSM should exhibit a minimum compressive strength of 150 psi at 7 days.

The CLSM should be allowed to cure appropriately and equipment should not be allowed on the CLSM if

the material exhibits a permanent deformation greater than ¼ inch. The proposed CLSM should be

submitted to the engineer of record for review and approval through a submittal process. The proposed

CLSM submittal should also contain compressive strength data for review and consideration by the

engineer of record.

If considered, the flexible base course shall meet the requirements of a TXDOT, Item 247, Type A,

Grade I-II flexible base course material and shall be moisture conditioned to ±2 percent of optimum

moisture content and compacted to a minimum of 100 percent of maximum density as determined by

ASTM D-1557 laboratory compaction procedure.

In general, the subgrade soils that shall support the replacement pavement section should be

moisture conditioned to ±3 percent of optimum moisture content and compacted to a minimum of 95

percent of maximum density as determined by ASTM D-1557 laboratory compaction procedures.

Section 9.0 – Additional Design and Construction Considerations

In pipeline excavations adjacent to existing structures, precautions should be taken not to

undermine or damage existing structures, footings, and/or utility lines. Precautions should be taken to

prevent distresses to nearby existing structures.

As typically expected with construction activities and pipeline excavation projects, a degree of

vibratory impacts should be expected. Our scope of work did not include an assessment of the condition

Page 20: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 18 of 21

of private structures or facilities adjacent to the pipeline project limits nor opinions or statements of potential

impacts. In accordance with the typical provisions of construction contracts the general contractor shall

be responsible for monitoring of existing structures. As required the general contractor shall develop a

vibration and ground settlement monitoring plan before, during the course of construction and after all

construction activities have been completed at the project site. The plan may include the set up of an array

of monitoring points near the pipeline aligment and at radial distances from construction activities to

monitor potential ground movements. It is recommended that the general contractor retain the services of

a licensed professional engineer or geologist to develop a monitoring plan and provide site monitoring

services as needed. It may be necessary for the contractor to establish a contingency plan for observed

movements of adjacent structures. The development of a settlement monitoring program was beyond our

scope of work; however we may meet with our Client and owner to further discuss this issue, as required.

The US Bureau of Mines, FHWA – “Geotechnical Instrumentation for Monitoring Field Performance”

manual and ASCE publications may be referenced to establish a monitoring plan and set maximum

vibration peak particle velocity and frequency thresholds to ensure that vibrations are maintained below

these limits during construction.

Section 10.0 – Project Specification Information

10.1 - Fill Materials

A. Select Fill soils shall consist of granular clayey, silty sands or sandy clayey, silty gravel mixtures,

free of clay lumps, deleterious materials, organic material, vegetation, cobbles or boulders over 3 inches

in nominal size. The Select Fill shall have a liquid limit less than 35 and a plasticity index of 12 or less.

The Select Fill shall also exhibit an optimum dry density of at least 115 pcf determined per ASTM D 1557.

Select Fill soils shall also meet the gradation requirements below.

Table 12. Select Fill Gradation Requirements

Sieve Size (square opening)

% Passing by Weight

3-inch 100

3/4-inch 75 – 100

No. 4 45 – 100

No. 200 5 – 45

Select Fill soils should classify as SP-SM, SM, SC, SC-SM, GM, GC, GC-GM, GP-GM, and GP-

GC in accordance with the USCS. It is not recommended that Select Fill consist of recycled concrete base

material or slag unless approved by the engineer of record.

Page 21: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 19 of 21

B. Native Fill Soil shall consist of granular clayey, silty sands or sandy gravel mixtures, free of clay

lumps, deleterious materials, vegetation, organic material, cobbles or boulders over 3 inches in nominal

size. The Native Fill soils shall have a liquid limit less than 35 and a plasticity index less than 12 or less.

Native Fill soils shall meet the gradation requirements below.

Table 13. Native Fill Soil Gradation Requirements

Sieve Size (square opening)

% Passing by Weight

3-inch 100

3/4-inch 75 – 100

No. 4 45 – 100

No. 200 3 – 45

Native Fill soils classified in the following list according to the USCS may be considered satisfactory

for use: SM, SW, SC, SP-SM, SP-SC, SC-SM, GW, GP, GM, GC, GP-GM and GP-GC, provided that these

soils also meet the requirements above.

Soils classified as CH, CL, MH, ML, OH, OL and PT or a combinations of these under the USCS

classification and soils that exhibit a plasticity index greater than 12 are not considered suitable for use as

Native Fill and Select Fill soil materials, unless approved by the engineer.

C. The following soil backfill classifications are typically designated for pipeline backfill. It

is not recommended that slag be utilized for the backfill material unless approved by the engineer of record.

Class I, Class II, Class III, and Class IV materials may be defined as follows:

D. CLASS I material may be manufactured angular, well-graded, crushed stone per ASTM D-2321

with a maximum particle size of 1½ inches. The following materials shall be acceptable under this

class designation: ASTM D-448 – Stone Sizes 4, 46, 5, 56, 57, and 6. Pea Gravel and other

uniformly graded material are not acceptable under this class. A gradation of Class I material shall

be submitted by the Contractor to the Engineer for approval prior to use.

E. CLASS II material may be coarse sands and gravels per ASTM D-2487 with maximum particle

size of 1½ inches, including variously graded sands and gravels, containing less than 12 percent

fines (material passing the #200 sieve) generally granular and non-cohesive, either wet or dry. Soil

types GW, GP, SW and SP are included in this class. (i.e., typically required within pipe zone).

Page 22: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 20 of 21

Proposed Class II material shall be submitted by the Contractor to the Engineer for evaluation and

approval prior to use.

F. CLASS III material may be fine sands, clayey sand mixtures, clayey gravel and sand mixtures,

suitable clean native sands and gravels. Class III materials shall also be free of clay lumps,

deleterious materials, cobbles or boulders over 3-inches in nominal size. Class III materials should

have a liquid limit less than 35 and a plasticity index less than or equal to 12 and exhibit an optimum

dry density of at least 115 pcf. Soils classified in the following list according to the USCS and ASTM

may be considered satisfactory for use as Class III backfill soil materials above the pipe zone as

approved by the project engineer of record: SM, SW, SC, SP-SM, SP-SC, SC-SM, GW, GP, GM,

GC, GP-GM and GP-GC. Proposed Class III material shall be submitted by the Contractor to the

Engineer for evaluation and approval prior to use.

G. CLASS IV and V material may be classified as CH, CL, MH, ML, OH, OL and PT under the

USCS. These soils shall not be used as embedment, pipe zone and backfill soil materials, unless

approved by the engineer of record. As indicated in Section 3.0 of this report Type III and IV soils

are consider Class IV soil materials.

10.2 - Construction Materials Testing

We recommend that construction materials inspection and testing of site work, fill placement,

excavations, concrete placement, and all other applicable materials and structures be performed by CQC.

The contractor shall perform testing in accordance with the guidelines presented above and/or as required

by the project specifications, whichever is more stringent. The specification testing program should include

the following testing frequencies as a minimum:

1. At least one (1) Laboratory Compaction Characteristics of Soil using Modified or Standard Effort (Proctor) for each type of material encountered or imported material to be used, according to ASTM D-1557 or D-698 as required by the project specifications. Additional soil samples for testing shall be requested by the General Contractor during the course of earthwork operations to ensure that the fill materials are maintained consistently within the specified requirements.

2. At least one (1) Soil Classification (Sieve Analysis and Atterberg Limits Test) for each type of material encountered or import material used, according to ASTM D 6913 and D-4318. Additional soil samples for testing shall be requested by the General Contractor during the course of earthwork operations to ensure that the fill materials are maintained consistently within the specified requirements.

3. A minimum of one (1) density test per 8-inch lift at 150 lineal feet spacings for pipe bedding and soil backfilling operations, according to ASTM D 6938 or D-1556.

Page 23: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

General Geotechnical Subsurface Soils Evaluation Report EPW – San Lorenzo Drainage Improvements Project Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration No. F-10632 Page 21 of 21

4. Sampling and testing for quality assurance of placed concrete materials should be performed for the project. Concrete field testing shall include testing for temperature, slump and air content (if required). The design strength of the concrete mix shall be evaluated by collecting cylindrical concrete compression test specimens for lab curing and testing in accordance with applicable ASTM procedures. At least one set of four (4) 6-inch x 12-inch or five (5) 4-inch x 8-inch concrete cylinders should be collected for every 50 cubic yards or less of placed concrete or as directed by the project engineer. The concrete specimens should be tested at 7 days (1 cylinder) and 28 days (3 cylinders) for verification of the specified design compressive strength or as directed by the project specifications. The ACI guidelines for hot weather and cold weather concreting should be followed to mitigate the potential poor performance of the concrete materials during significant periods of high (above 95° F) and low (below 35° F) temperatures.

Section 11.0 – Soils Evaluation Considerations and Limitations

The analysis and recommendations in this report are based on the data obtained from a total of

two (2) vertical borings performed at the approximate locations indicated on the attached General

Geotechnical Subsurface Exploration Boring Location Aerial Plan, Sheets A1-1. This report may not reflect

all the subsurface soil variations that may occur near and/or between the boring logs. The nature and

extent of the variations may not become evident until during the course of construction.

If variations appear during construction, CQC should be contacted immediately, it may be

necessary to re-evaluate our information and/or recommendations provided within this report to be made

after performing on-site observations during the construction period and noting the characteristics of any

variations.

The scope of our soil evaluation did not include surveying services, ground water study, preparation

of engineering plans, slope stability analysis, sinkhole study and landslide study, delineation of buried

material or structures, specifications, cost estimates, an environmental assessment of the property's air,

soil, water, site fault delineation and evaluation, preparation of a dewatering plan, trench safety and/or

shoring plan, delineation of subsurface flowing water either on or adjacent to the pipeline limits, therefore

no opinions and/or conclusions are presented in this report. Our geotechnical scope of work for this site

did not include an environmental assessment or chemical testing and analysis of the subsurface soils.

D:\Dropbox\CQC Files\CQC Working Files\GEO\Reports\2019\19-037 EPW-San Lorenzo Dr Imp (CEA)\07-Final Report Documents\19-037-Final Report.docx

Page 24: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing Geotechnical Engineering Environmental Site Assessments Forensic Analysis/Testing

APPENDIX A

“People Committed to Delivering Top-Quality Services Consistently”

Page 25: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Client: CEA Group

CQC Project No. AGCQC19-037

Scale: NTS Check by: JR

Date: 11/06/19 Sheet A1-1

General Geotechnical Subsurface Exploration Boring Location Aerial Plan

EPW - San Lorenzo Drainage Improvements San Lorenzo Avenue from Carl Longuemare Road

to Southside Road El Paso, El Paso County, Texas

Note * Vertical boring locations are approximate.

As per Client, Approximate

Location of Project Area.

LEGEND

B-1: Exploration Boring Number, Approximate Depth and Location.

San Lorenzo Avenue

B-2 (10’)*

B-1 (10’)*

Page 26: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Client: CEA Group

CQC Project No. AGCQC19-037

Scale: NTS Check by: JR

Date: 11/06/19 Sheet A1-2

City of El Paso - Flood Zone Aerial Plan

EPW – San Lorenzo Avenue Drainage Improvements Project

Carl Longuemare Road to Southside Road El Paso, El Paso County, Texas

FLOOD ZONE

FLOOD ZONE

Approximate limits of the project area

FLOOD ZONE

FLOOD ZONE

FLOOD ZONE

Page 27: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

SS1

SS2

SS3

SS4

95

8

2

5799

99

99

35.8

6.6

2.5

3-3-14(17)

3-2-5(7)

3-3-5(8)

2-3-6(9)

CH

SP

2.5

Asphaltic Concrete Pavement - Approx. 3 in. thick.Apparent Base Course Material: Approx. 5 in. thick.

FAT CLAY, High Plasticity, Brown, Stiff, Moist to Wetwith traces of sand.- Clay soils shall be susceptible to consolidationsettlement and swelling.

SAND, Fine to Medium Grained, Poorly Graded, LightBrown, Loose, Slightly Moist to Moist with silt. These soilsmay be susceptible to soil sloughing during excavationfrom approx. 2-1/2 feet to 10 feet.

SAND, Fine to Medium Grained, Poorly Graded, LightBrown to Multicolored, Loose, Dry. These soils may besusceptible to soil sloughing during excavation.

NOTE: SS- Split Spoon Sample

Bottom of borehole at 10.0 feet.

NOTES Boring Location: See Attached Boring Location Plan, Sheet A1-1

LOGGED BY PG

DRILLING METHOD CME-75 w/3-1/4" ID HSA

GROUND WATER LEVELS:

CHECKED BY BL

DATE STARTED 9/16/19

AT TIME OF DRILLING ---

AT END OF DRILLING ---

AFTER DRILLING ---

HOLE SIZE 6 inchesGROUND ELEVATION Ext. Grade

DRILLING CONTRACTOR CQC

COMPLETED 9/16/19

DRILLED BY DN

DE

PT

H(f

t)

0.0

2.5

5.0

7.5

10.0

GR

AP

HIC

LOG

SA

MP

LE T

YP

EN

UM

BE

R

% -

200

PI

(LL-

PL)

Sheet A2

% -

4

% M

oist

ure

Con

tent

BLO

WC

OU

NT

S(N

VA

LUE

)

US

CS

% - 200 20 40 60 80

16 32 48 64

PL LLMC

SPT N VALUE 10 20 30 40

Poc

ket P

en.

(tsf

)

MATERIAL DESCRIPTION

BORING NUMBER B-1

CLIENT CEA Group

PROJECT NUMBER AGCQC19-037

PROJECT NAME EPW San Lorenzo Drainage Improvements Project

PROJECT LOCATION Carl Longuemare Road to Southside Road

CQ

C S

TA

ND

AR

D L

OG

W/ P

OC

KE

T P

EN

19-

037

LOG

S.G

PJ

GIN

T S

TD

US

LA

B.G

DT

T

HE

INF

OR

MA

TIO

N P

RE

SE

NT

ED

SH

OU

LD N

OT

BE

SE

PA

RA

TE

D F

RO

M T

HE

GE

OT

EC

HN

ICA

L R

EP

OR

TCQC Testing and Engineering LLC - TBPE Firm No. F-106324606 Titanic AvenueEl Paso, Texas 79904Ph: (915) 771-7766Fx: (915) 771-7786

Page 28: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

SS1

SS2

SS3

SS4

90

55

47

799

99

99

21.2

9.8

9.0

8-4-3(7)

3-3-4(7)

3-4-5(9)

3-3-4(7)

ML2.0

Asphaltic Concrete Pavement - Approx. 3 in. thick.Apparent Base Course Material: Approx. 4 in. thick.

SILT, Low Plasticity, Brown to Dark Brown, Soft, VeryMoist with some sand.- Silts soils shall be suceptible to consolidation settlement.

- Moist below approx. 2-1/2 feet.

SAND, Fine to Medium Grained, Silty, Light Brown,Loose, Moist. These soils may be susceptible to soilsloughing during excavation below approx. 5 feet.

SAND, Fine to Medium Grained, Poorly Graded, Brown toMulticolored, Loose, Dry to Slightly Moist. These soilsmay be susceptible to soil sloughing during excavation.

NOTE: SS- Split Spoon Sample

Bottom of borehole at 10.0 feet.

NOTES Boring Location: See Attached Boring Location Plan, Sheet A1-1

LOGGED BY PG

DRILLING METHOD CME-75 w/3-1/4" ID HSA

GROUND WATER LEVELS:

CHECKED BY BL

DATE STARTED 9/16/19

AT TIME OF DRILLING ---

AT END OF DRILLING ---

AFTER DRILLING ---

HOLE SIZE 6 inchesGROUND ELEVATION Ext. Grade

DRILLING CONTRACTOR CQC

COMPLETED 9/16/19

DRILLED BY DN

DE

PT

H(f

t)

0.0

2.5

5.0

7.5

10.0

GR

AP

HIC

LOG

SA

MP

LE T

YP

EN

UM

BE

R

% -

200

PI

(LL-

PL)

Sheet A3

% -

4

% M

oist

ure

Con

tent

BLO

WC

OU

NT

S(N

VA

LUE

)

US

CS

% - 200 20 40 60 80

16 32 48 64

PL LLMC

SPT N VALUE 10 20 30 40

Poc

ket P

en.

(tsf

)

MATERIAL DESCRIPTION

BORING NUMBER B-2

CLIENT CEA Group

PROJECT NUMBER AGCQC19-037

PROJECT NAME EPW San Lorenzo Drainage Improvements Project

PROJECT LOCATION Carl Longuemare Road to Southside Road

CQ

C S

TA

ND

AR

D L

OG

W/ P

OC

KE

T P

EN

19-

037

LOG

S.G

PJ

GIN

T S

TD

US

LA

B.G

DT

T

HE

INF

OR

MA

TIO

N P

RE

SE

NT

ED

SH

OU

LD N

OT

BE

SE

PA

RA

TE

D F

RO

M T

HE

GE

OT

EC

HN

ICA

L R

EP

OR

TCQC Testing and Engineering LLC - TBPE Firm No. F-106324606 Titanic AvenueEl Paso, Texas 79904Ph: (915) 771-7766Fx: (915) 771-7786

Page 29: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

0.0010.010.1110100

BOREHOLE DEPTH Classification PL PI Cc Cu78 57

0.90

1.13

1.69

2.53

95.0

8.0

2.0

GRAVEL SANDSILT OR CLAY

1403 4 20 406 603 10024 16 30

%Clay

0.077

0.099

0.094

0.167

0.129

0.251

9.5

9.5

9.5

1 2006 101.5 8 143/4 3/8

PE

RC

EN

T F

INE

R B

Y W

EIG

HT

SOIL PARTICLE SIZEANALYSIS TESTS

Test Method: ASTM D6913

B-1

B-1

B-1

GRAIN SIZE IN MILLIMETERS

LL21

D60 D30 D10 %Gravel %Sand1.0

1.0

1.0

fine coarse

501/2HYDROMETERU.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS

B-1

B-1

B-1

FAT CLAY(CH)

POORLY GRADED SAND(SP)

0.7 - 2.2

2.5 - 4.0

8.5 - 10.0

BOREHOLE DEPTH D100 %Silt4.0

91.0

97.0

0.7 - 2.2

2.5 - 4.0

8.5 - 10.0

COBBLEScoarse medium fine

CLIENT CEA Group

PROJECT NUMBER AGCQC19-037

PROJECT NAME EPW San Lorenzo Drainage Improvements Project

PROJECT LOCATION Carl Longuemare Road to Southside Road

GR

AIN

SIZ

E 1

9-03

7 LO

GS

.GP

J G

INT

ST

D U

S L

AB

.GD

T

TH

E IN

FO

RM

AT

ION

PR

ES

EN

TE

D S

HO

ULD

NO

T B

E S

EP

AR

AT

ED

FR

OM

TH

E G

EO

TE

CH

NIC

AL

RE

PO

RT

CQC Testing and Engineering LLC - TBPE Firm No. F-106324606 Titanic AvenueEl Paso, Texas 79904Ph: (915) 771-7766Fx: (915) 771-7786

Sheet A4

Page 30: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

0.0010.010.1110100

BOREHOLE DEPTH Classification PL PI Cc Cu30 7

90.0

55.0

47.0

GRAVEL SANDSILT OR CLAY

1403 4 20 406 603 10024 16 30

%Clay

0.082

0.092

9.5

9.5

9.5

1 2006 101.5 8 143/4 3/8

PE

RC

EN

T F

INE

R B

Y W

EIG

HT

SOIL PARTICLE SIZEANALYSIS TESTS

Test Method: ASTM D6913

B-2

B-2

B-2

GRAIN SIZE IN MILLIMETERS

LL23

D60 D30 D10 %Gravel %Sand1.0

1.0

1.0

fine coarse

501/2HYDROMETERU.S. SIEVE OPENING IN INCHES U.S. SIEVE NUMBERS

B-2

B-2

B-2

SILT(ML)0.6 - 2.1

2.5 - 4.0

5.0 - 6.5

BOREHOLE DEPTH D100 %Silt9.0

44.0

52.0

0.6 - 2.1

2.5 - 4.0

5.0 - 6.5

COBBLEScoarse medium fine

CLIENT CEA Group

PROJECT NUMBER AGCQC19-037

PROJECT NAME EPW San Lorenzo Drainage Improvements Project

PROJECT LOCATION Carl Longuemare Road to Southside Road

GR

AIN

SIZ

E 1

9-03

7 LO

GS

.GP

J G

INT

ST

D U

S L

AB

.GD

T

TH

E IN

FO

RM

AT

ION

PR

ES

EN

TE

D S

HO

ULD

NO

T B

E S

EP

AR

AT

ED

FR

OM

TH

E G

EO

TE

CH

NIC

AL

RE

PO

RT

CQC Testing and Engineering LLC - TBPE Firm No. F-106324606 Titanic AvenueEl Paso, Texas 79904Ph: (915) 771-7766Fx: (915) 771-7786

Sheet A5

Page 31: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

B-1 0.7- 2.2 17 35.8 78 21 57 99 95 2.5 CH

2.5- 4.0 7 6.6 99 8

5.0- 6.5 88.5- 10.0 9 2.5 99 2 SP

B-2 0.6- 2.1 7 21.2 30 23 7 99 90 2.0 ML

2.5- 4.0 7 9.8 99 55

5.0- 6.5 9 9.0 99 47

8.5- 10.0 7

LiquidLimit

PlasticLimit

PlasticityIndex

WaterContent

(%)Borehole % Passing

No. 200N - Value % Passing

No. 4

SUMMARY OF LABORATORYENGINEERING SOIL CLASSIFICATION TEST

RESULTS

Depth ClassificationPocket Pen.(tsf)

TotalUnit

Weight(pcf)

CLIENT CEA Group

PROJECT NUMBER AGCQC19-037

PROJECT NAME EPW San Lorenzo Drainage Improvements Project

PROJECT LOCATION Carl Longuemare Road to Southside Road

LAB

SU

MM

AR

Y

19-0

37 L

OG

S.G

PJ

GIN

T S

TD

US

LA

B.G

DT

T

HE

INF

OR

MA

TIO

N P

RE

SE

NT

ED

SH

OU

LD N

OT

BE

SE

PA

RA

TE

D F

RO

M T

HE

GE

OT

EC

HN

ICA

L R

EP

OR

TCQC Testing and Engineering LLC - TBPE Firm No. F-106324606 Titanic AvenueEl Paso, Texas 79904Ph: (915) 771-7766Fx: (915) 771-7786

Sheet A6

Page 32: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing

Geotechnical Engineering

Environmental Site Assessments

Forensic Analysis/Testing

PROJECT NO.: AGCQC19-037

PROJECT NAME: General Geotechnical Subsurface Soils Evaluation

EPW - San Lorenzo Drainage Improvements Project

Carl Longuemare Road to Southside Road

El Paso, El Paso County, Texas

PROCTOR NO.: 1 SAMPLED BY: PG

SOIL SAMPLE LOCATION: SAMPLE DATE: 9/16/2019

SOIL SAMPLE APPROX. DEPTH: 1 to 3'

SOIL TYPE/DESCRIPTION:

Sieve Analysis Test Atterberg Limits Test

Test Method: ASTM D 6913 Test Method: ASTM D 4318

Sieve Size/No.Percent

Retained

Percent

PassingLimit Test

Index Test

Result

3" 0 100 LL 39

2-1/2" 0 100 PL 16

1-1/2" 0 100 PI 23

1" 0 100 NP-Non Plastic

3/4" 0 100 NS - Not Specified

1/2" 0 100

3/8" 0 100 Soil Classification: CL

No. 4 3 97 Test Method:

No. 10 12 88

No. 40 24 76

No. 100 30 70

No. 200 35 65

NS- Not Specified

Moisture-Density Relationship TestTest Method: ASTM D 1557, Method "B"

Test Sample No.Moisture

Content (%)

Sample Dry

Density (pcf)

1 11.4 107.7

2 13.3 110.1

3 15.6 111.3

4 17.5 109.1

111.3

15.4

ASTM D 2487

Maximum Dry Density, pcf:

Optimum Moisture Content, %:

On Site Subsurface Soils / CLAY, Plastic, Sandy, Brown

SAMPLE TEST RESULTS

SOIL MOISTURE - DENSITY RELATIONSHIP TEST RESULTS

SAMPLE INFORMATION

B-1

107.0

108.0

109.0

110.0

111.0

112.0

10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0

So

il D

ry D

ensity, pcf

Soil Moisture Content, %

Moisture - Density Curve

CQC Testing and Engineering, L.L.C.

TBPE Firm Registration No. F-10632 Sheet A7

Page 33: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

4606 Titanic Avenue

El Paso, Texas 79904

Ph. (915) 771-7766

Fx. (915) 771-7786

PROJECT NO.: AGCQC19-024

PROJECT NAME: General Geotechnical Subsurface Soils EvaluationProposed Shopping Center Project

El Paso, El Paso County, Texas

PROCTOR NO.: 1 SAMPLED BY: PG

SOIL SAMPLE LOCATION: SAMPLE DATE: 10/3/2019

SOIL SAMPLE DEPTH: 1 to 3'

SOIL TYPE/DESCRIPTION:

TEST SPECIMEN INFORMATION: SPECIMEN SWELL TEST INFORMATION:

Soil Sample Height, in. 4-1/2" Intial Swell Reading: 0.4130

Soil Sample Approx. Diameter, in. 6" Final Swell Reading: 0.8610

Sample Vertical Swell, % 9.9556

Soil Optimum Dry Density, pcf 111.3

Soil Optimum Moisture Content, % 15.4 Before Soaking After Soaking

Dry Density, pcf 106.6 89.0

CBR Test Data: Moisture, % 15.2 37.9

% Compaction 95.8 80.0

Stress Contact Area, in2

3.02

Sample Surcharge Load, lbs. 12.5 UNCORRECTED CALCULATED SOAKED CBR VALUES:

Soaking Period, hr's. 96

CBR @ 0.1" Penetration 1

CBR @ 0.2" Penetration 1

PEN. Load, lbs. Stress, psi

0 0 0

0.01 10 3

0.02 10 3

0.03 19 6

0.04 19 6

0.05 19 6

0.06 19 6

0.07 19 6

0.08 29 10

0.09 29 10

0.1 29 10

0.15 38 13

0.2 48 16

Stress Versus Penetration Data

SOIL CALIFORNIA BEARING RATIO (CBR) TEST RESULTSASTM D - 1883

SAMPLE INFORMATION

B-1

On Site Subsurface Soils / CLAY, Plastic, Sandy, Brown

0

5

10

15

20

0 0.05 0.1 0.15 0.2

Calc

ula

ted

Te

st S

am

ple

C

on

tact S

tress, p

si

Piston Penetration, in.

CBR TestStress - Penetration Test Data

CQC Testing and Engineering, L.L.C.

TBPE Firm Registration No. F-10632

Sheet A8

Page 34: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing

Geotechnical Engineering

Environmental Site Assessments

Forensic Analysis/Testing

CQC Testing and Engineering, L.L.C.

TBPE Firm Registration No. F-10632 Sheet A9

PROJECT NO.: AGCQC19-037

PROJECT NAME: General Geotechnical Subsurface Soils Evaluation

EPW - San Lorenzo Drainage Improvements Project

El Paso, El Paso County, Texas

SAMPLE LOCATION: Composite Sample B-1 and B-2

SAMPLE DEPTH: 5 to 10 feet

Water Added (mL) Dial Reading Multiplier Resistance (ohms) Box Factor Resistivity (ohms-cm)

100 3.4 10 3

3,400 0.45 1,530

150 1.0 10 3

1,000 0.45 450

200 0.7 10 3

700 0.45 315

250 0.5 10 3

500 0.45 225

300 0.4 10 3

400 0.45 180

SOIL TYPE/DESCRIPTION: SAND, Fine to Medium Grained, Poorly Graded, Light Brown to Multicolored

The approximate resistivity readings reported above are in accordance with TxDOT Designation: Tex-129-E test

procedure.

SOIL RESISTIVITY TEST RESULTS

MEASURING THE RESISTIVITY OF SOIL MATERIALS

TxDOT Designation: Tex-129-E

0

500

1,000

1,500

2,000

2,500

3,000

3,500

4,000

0 50 100 150 200 250 300 350

Re

sis

tivit

y (

oh

ms

)

Water Content (mL)

Soil Resistivity Versus Water Content

Page 35: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing Geotechnical Engineering Environmental Site Assessments Forensic Analysis/Testing

APPENDIX B

“People Committed to Delivering Top-Quality Services Consistently”

Page 36: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing Geotechnical Engineering

Environmental Site Assessments Forensic Analysis /Testing

CQC Testing and Engineering, LLC. Sheet B1 TBPE Firm Registration No. F-10632

GEOTECHNICAL REPORT TECHNICAL REFERENCE INFORMATION

DEFINITION OF DESCRIPTIVE TERMS

DENSITY OF GRANULAR SOILS CONSISTENCY OF COHESIVE SOILS SPT N Value Relative Density SPT N Value Consistency < 4 Very Loose < 2 Very Soft 4 – 10 Loose 2 – 4 Soft 11 – 30 Med. Dense 5 – 8 Medium Stiff 31 – 50 Dense 9 – 15 Stiff 50 – 80 Very Dense 16 – 50 Very Stiff > 80 Hard > 80 Very Hard

DEGREE OF PLASTICITY

Nonplastic – Has no cohesion; will not roll into a thread. Trace of Plasticity – Barely hold its shape when rolled into a thread. Low Plasticity – Has sufficient cohesion to form a thread but will quickly rupture when deformed. Med. Plasticity – Has considerable cohesion. Can be molded into a thread and will withstand considerable deformation without rupture. High Plasticity – Can be kneaded like dough without trace of rupture.

MOISTURE DESCRIPTIONS

GRANULAR SOILS COHESIVE SOILS

Dry No Apparent Moisture No Apparent Moisture Slightly Moist < Than 3% by Weight < Less Than Plastic Limit

Moist 3% to 9% by Weight Approximately Plastic Limit Very Moist > 9% by Weight > than PL but < than LL Wet Submerged or Saturated Submerged or Saturated

PLASTICITY Cohesion Plasticity Degree of TSF Index Plasticity 0-0.125 0-5 None 0.125-0.25 5-10 Low 0.25-0.5 10-20 Moderate 0.5-1.0 20-40 Plastic 1.0-2.0 > 40 Highly Plastic > 2.0

ABBREVIATIONS

V. – Very Fl. – Fairly Sl. – Slightly Med. – Medium Tr. – Trace < - Less Than > - Greater Than PL – Plastic Limit Mod. – Moderately

Page 37: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing Geotechnical Engineering

Environmental Site Assessments Forensic Analysis /Testing

CQC Testing and Engineering, LLC. Sheet B2 TBPE Firm Registration No. F-10632

SOIL CLASSIFICATION CHART

Page 38: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

Construction Materials Testing Geotechnical Engineering

Environmental Site Assessments Forensic Analysis /Testing

CQC Testing and Engineering, LLC. Sheet B3 TBPE Firm Registration No. F-10632

GEOTECHNICAL REPORT SOIL CLASSIFICATION REFERENCE INFORMATION

Cohesive Soil Classification Chart

U.S. STANDARD SIEVE 12” 3” ¾” 4 10 40 200

BOULDERS COBBLES GRAVEL SAND SILT CLAY COARSE FINE COARSE MEDIUM FINE

152 76.2 19.1 4.76 2.00 0.420 0.074 0.002

SOIL GRAIN SIZE IN MILLIMETERS

Laboratory Test Methods: Moisture Content Tests: Moisture Contents are determined from representative portions of a soil sample. The samples initial weight is recorded and it is then dried to a constant weight. From this data the moisture content is calculated. Atterberg Limit Tests: Liquid Limit (LL), Plastic Limit (PL) and Shrinkage Limit (SL) tests are performed to aid in the classification of soils and to determine the plasticity and volume change characteristics of the materials. The Liquid Limit is the minimum moisture content at which a soil will flow as a heavy viscous fluid. The Plastic Limit is the minimum moisture content at which the soil behaves as a plastic material. The Shrinkage Limit is the moisture content below which no further volume change will take place with continued drying. The Plasticity Index (PI) is the numeric difference between the Liquid Limit and the Plastic Limit and indicates the range of moisture content over which a soil remains plastic. Grain Size Distribution Test (Particle Size Analysis, Sieve Analysis): The distribution of soils finer than the No. 200 sieve is determined by passing a representative soil sample through a standard set of nested sieves. The weight of material retained on each sieve is determined and the percentage passing (or retained) is calculated. For determination of the percentage of material finer than the No. 200 sieve, the specimen is first washed through the sieve. The distribution of the materials finer than the No. 200 is determined by use of the different size particles while suspended in water.

Page 39: GENERAL GEOTECHNICAL SUBSURFACE SOILS EVALUATION … · El Paso, El Paso County, Texas CQC Project No. AGCQC19-037 CQC Testing and Engineering, L.L.C. November 6, 2019 TBPE Firm Registration

“People Committed to Delivering Top-Quality Services Consistently” Local El Paso, Texas Firm