General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil...

114
Tarifa de precios _ junio 2013 España y Portugal General Catalogue 2013-2014

Transcript of General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil...

Page 1: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

Tarifa de precios _ junio 2013

España y Portugal

General Catalogue 2013-2014

Page 2: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

The guaranteeof the leader,

the qualityof the specialist

Page 3: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

2

A

B

C

AIR/AIR Inverter, compact and split units. Page 8

AIR/AIR ON/OFF compact and split units Page 14

CLVA-CLVBA ductable indoor units Page 26

Ductable axial condenser units Page 29

Heat recovery units Page 34

SELF-CONTAINED AIR-TO-AIR UNITS

Roof Top standard version axial fans Page 38

Roof Top standard version axial fans RCF cooling recovery Page 40

Roof Top standard version centrifugal fans Page 42

Roof Top standard version RCF centrifugal fans cooling recovery Page 44

Roof Top standard version MINI centrifugal fans Page 46

ROOF TOP AIR TO AIR

WATER/AIR compact horizontal COAXIAL exchanger Page 50

WATER/AIR compact horizontal PLATES exchanger Page 52

AIR/AIR compact vertical COAXIAL exchanger Page 54

WATER/WATER compact vertical PLATES exchanger Page 56

SELF-CONTAINED WATER TO AIR UNITS

TABLE OF CONTENTS

Page 4: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

3

D

E

F

MINI ADVANCE i, AIR/WATER units axial fans Page 62

MINI KRONO X, AIR/WATER units axial fans Page 63

KRONO X, AIR/WATER units axial fans medium power Page 65

ADVANCE X, AIR/WATER units axial fans high power, scroll Page 68

ADVANCE XT, AIR/WATER units axial fans high power, screw Page 70

KRONO C, AIR/WATER units centrifugal fans medium power Page 72

ADVANCE W, WATER/WATER units scroll compressors Page 74

ADVANCE WT, WATER/WATER screw compressors Page 77

WATER CHILLER UNITS

FCW/FCCW, 2T and 4T vertical and horizontal fan coil with and without housing Page 80

FKW and FKWS, 4-way 2T and 4T cassette fan coil Page 84

FPW, wall mounted fan coil Page 86

BSW, fan coil installation high pressure ducts available Page 87

BHW, ductable fan-coil Page 90

EHW, horizontal air conditioning units Page 92

CLW, indoor units for connection to vertical ducts Page 94

EHWM, air handling units Page 96

FAN COILS AND AIR HANDLING UNITS

REGULATION AND CONTROL Page 97

Page 5: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

4

02.

01.Reason for beingHitecsa, leader in the European market in the design, manufacturing and prescription of air conditioning equipment, is an international benchmark in terms of flexibility and productive punctuality.

Our reason of being is to support our customers throughout the entire life-cycle of their equipment. We strive to understand our customers' needs for air-conditioning comfort and well-being and to provide them with

advice on the selection of the right equipment, as well as offering the best possible level of after-sales service. Our team of specialists and engineers offers you a personalised technical consulting service, helps you choose the best air-conditioning solution for your needs, and offers you assistance during the entire life-cyle of the unit.

Our large head offices in Vilanova i la Geltrú, Barcelona, cover over 10,000 m2, allowing us to offer a top-quality service in logistics, R&D, manufacturing, and assembly. At these facilities, our equipment is subjected to functional tests to ensure the quality of all products.

Our R&D Department guarantees the develop-ment of efficient and environmentally friendly products. In addition to the internal quality control procedures, HITECSA products are subjected to EUROVENT certification procedures, a leading European certification body in the European air-conditioning market.

Since1982We have been leaders in the market since 1982. Since then, all of our departments have evolved in line with the changes required by the new needs of our customers and the changes brought about by standards regarding environmental and energy efficiency.

1982HITECSA was foundedin Vilanova i la Geltrú (Barcelona)

1995The H2 plant was opened, where the head offices and assembly plant are currently located.

2003Updating of the production unit to speed up the response times to the needs of our customers.

2007Start up of the HITECSA Schooltraining courses.

2012The new property promotes the development of new products from the optimisation of the R&D department.

TodayOver 100 workers on the staff. 10,000 m2 of facilities devoted to the design and manufacture of equipment.

Plans for the futureContinuous innovation of our product range in terms of energy efficiency, respect for the environment and cost optimisation in order to adapt it to the needs of our customers.Continuous improvement of our customer services.Geographic expansion and increase of our network of collaborators

Our reason for being isto support our customers throughout the entire life-cycle of their equipment

Page 6: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

5

04.

03.Team

José María, Ricardo, Josep Manel, Sonia, Josep, Constanza... just some of over 100 specialists. People are our best capital. We are not machines. We are a team of people at the service of our customers.

Behind a telephone number or e-mail address, you will always find a name – a person who can help you to find an answer to any technical, administrative or commercial doubt or query.

The training and experience of our team guarantees the quality of all of our equipment and services.

DedicationTo the customerWe adapt to our customers' needs, both in terms of delivery times and with regard to the specific characteristics of their projects, offering the best pre- and after-sales advice and the highest possible quality.

Our production system, structured into separate cells, allows us to offer a totally flexible assembly chain so that we can manufacture products which are 100% tailor-made – in the time required by our customers, with the quality they expect, and serviced and installed where they need them.

FlexibilitySpeedSupportQuality

A teamof specialists

at your service

Page 7: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

6

06.

05.

Solutionspost-installationWe support you throughout the life-cycle of your air-conditioning unit, both with training at our Hitecsa School and with spare parts, thanks to our new SERV-HIPLUS division. Our post-sales department is in charge of coordinating and providing technical assistance and our website allows you to quickly find all up-to-date technical information on our products.

Our technical departments are responsible for finding out about our customers' air-conditioning needs and offering an engineering and design service which allows customers to find the best possible unit for their project from our range of equipment.

HITECSA also designs tailor-made solutions which meet customers' expectations regarding technical features, energy efficiency, costs and delivery times – all in line with the required time period and geographic location.

Solutionspre-installation

We design solutions,we shape your comfort

Spare partsWith the aim of improving the quality of our service, we have implemented a series of improvements in our spare parts department, strengthening the team devoted to this area and updating the prices of the components. The management of requests is carried out by our team of technicians, who personally contact our customers to track progress and make sure that requests are answered as soon as possible.

HITECSA Training SchoolAt our facilities in Vilanova i la Geltrú (Barcelona), training courses are given for all professionals in the sector who wish to increase their knowledge of air conditioning systems and the operation of HITECSA products.We also offer our collaborators and customers the option of participating in tailor-made courses at their own premises.

POST-SALESWe have a network of official service technicians in all major cities who, in conjunction with approved service technicians, provide fast and reliable service coverage for the whole country. Our head office has a special after-sales service telephone team. The in-house post-sales team can make on-site visits in order to provide support for commissioning or to check that equipment is working correctly.

Page 8: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

AAIR/AIR Inverter, compact and split units Page 8

AIR/AIR ON/OFF compact and split units Page 14

CLVA-CLVBA ductable indoor units Page 26

Ductable axial condenser units Page 29

Heat recovery units Page 34

SELF-CONTAINED AIR-TO-AIR UNITS

Page 9: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

8

A01

ACHIA/ACHIBA

ECHIA/CCHIA – ECHIBA/CCHIBA

601, 741 901

ECHIA/ECHIBA CCHIA/CCHIBA 601, 741 CCHIA/CCHIBA 901

ECHIA/CCHIA – ECHIBA/CCHIBAACHIA/ACHIBA

COMPACT/SPLIT HORIZONTAL INVERTER

ACHIACooling only

ECHIA/CCHIACooling only

ACHIBAHeat pump

ECHIBA/CCHIBAHeat pump

COMPACT configuration SPLIT configuration

• Variable airflow for the outdoor fan

• Three air speeds in the Indoor Fan

• Cooling capacities ranging from 4 to 29 kW

This range of units are self-contained horizontal units suitable for connection to both indoor and outdoor sections of a network of air distribution ducts.

Designed to be installed inside the building to be air-conditioned, they are characterised by offering great flexibility in the installation.

• EER/COP coefficient ranging from 3.2 in nominal temperature conditions

• Scroll compressors with soft-start

• R410A refrigerant

• Can be combined with the RCAH range of heat recovery units of high energy efficiency and filters up to F Class.

• DC inverter technology: maximum savings and comfort

• Low sound level

• High performance in heat pump for low outdoor temperatures as low as -15°C

SELF-CONTAINED AIR-TO-AIR UNITS

Inverter High Energy Efficiency at the service of energy rehabilitation in the commercial sector

MAIN FEATURES

• Operating limit in cooling mode with outdoor temperature of 48°C

• Soft-start of the indoor and/or outdoor fan

• Oil separator (only for split units)

• ON/OFF remote

• Remote cooling/heating

• Scheduling function and Modbus connection

• Controls supplied as standard TH Tune

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

Page 10: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

9

A01

MODEL 601 741 901

Maximum cooling capacity (120 Hz) kW 17.3 22.4 28.9

Maximum cooling capacity (120 Hz) R.T. 4.9 6.4 8.2

Maximum heating capacity (120 Hz) kW 18.6 24.2 28.9

Nominal cooling capacity (80 Hz) kW 12.9 16.6 20.6

Nominal cooling capacity (80 Hz) R.T. 3.7 4.7 5.9

Nominal heating capacity (80 Hz) kW 13.0 15.7 20.4

Maximum EER coefficient kW/kW 3.16 2.95 2.90

Maximum COP coefficient kW/kW 3.21 3.03 2.93

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N

Nominal indoor airflow in cooling m3/h 2300 3000 3700

Nominal indoor airflow in heating m3/h 2800 3600 4400

Max. int. airflow – static pressure m3/h – Pa 3600 – 70 4600 – 80 5600 – 90

Max out. airflow – static pressure m3/h – Pa 5600 – 50 6200 – 50 7,500 – 50

Dimensions (length x width x height) mm 1755x1697x640 1755x1697x640 1998x1755x672

Net weight Kg 375 420 495

ACHIA-ACHIBA TECHNICAL SPECIFICATIONS

MODEL 601 741 901

Maximum cooling capacity (120 Hz) kW 17.3 22.4 26.5

Maximum cooling capacity (120 Hz) R.T. 4.9 6.4 7.5

Maximum cooling capacity (120 Hz) kW 18.6 24.2 28.9

Nominal cooling capacity (80 Hz) kW 12.9 16.6 20.6

Nominal cooling capacity (80 Hz) R.T. 3.7 4.7 5.9

Nominal cooling capacity (80 Hz) kW 13.0 15.7 20.4

Maximum EER coefficient kW/kW 3.16 2.95 2.90

Maximum COP coefficient kW/kW 3.21 3.03 2.93

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 1/2 5/8 5/8

Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8

Max out. airflow – static pressure m3/h – Pa 5600 – 50 6200 – 50 7500 – 50

Dimensions (length x width x height) mm 1755x1004x640 1755x1004x640 1750x1057x662

Net weight Kg 240 295 312

OUTDOOR UNIT (CCHIA/CCHIBA) TECHNICAL SPECIFICATIONS

MODEL 601 741 901

Maximum cooling capacity (120 Hz) kW 17.3 22.4 28.9

Maximum cooling capacity (120 Hz) R.T. 4.9 6.4 8.2

Maximum cooling capacity (120 Hz) kW 18.6 24.2 28.9

Nominal cooling capacity (80 Hz) kW 12.9 16.6 20.6

Nominal cooling capacity (80 Hz) R.T. 170.9 210.7 256.2

Nominal cooling capacity (80 Hz) kW 13.0 15.7 20.4

Maximum EER coefficient kW/kW 3.16 2.95 2.90

Maximum COP coefficient kW/kW 3.21 3.03 2.93

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 1/2 5/8 5/8

Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8

Nominal indoor airflow in cooling m3/h 2300 3000 3700

Nominal indoor airflow in heating m3/h 2800 3600 4400

Max. int. airflow – static pressure m3/h – Pa 3600 – 70 4600 – 80 5500 – 90

Dimensions (length x width x height) mm 1755x752x640 1755x752x640 1750x900x662

Net weight Kg 145 150 180

INDOOR UNIT (ECHIA/ECHIBA) TECHNICAL SPECIFICATIONS

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 11: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

10

A01

ENERGY SAVING

Option of mixing module for semi-enthalpy free cooling with two dampers

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Option of manufacturing units with symmetric configuration

Outdoor installation kit

Upgraded motors

Anti-freeze heater for collection tray

Fireproof filter class M0

Hot water heating coils

Electrical heating as backup in defrosting

Anti-corrosion pre-treated coils

Prepared for disassembly

Quick-connect valves with preload of refrigerant gas (only for SPLIT configuration)

MAINTENANCE

Service valves

External Schrader valves for pressure

test (standard for the 901 model)

Clogged filter indication

Condenser filter

Split filter

REGULATION AND CONTROL

Alarm indication

Smoke detection

Separate electrical panel

Ambient temperature or wall mounted sensor

Discharge temperature sensor

Centralised integrated management

operation

Operation without neutral

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 12: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

11

ACVIA/ACVIBA ECVIA/ECVIBA – CCVIA/CCVIBA

ECVIA/ECVIBA 601.741.901 CCVIA/CCVIBA 601.741.901

A01

ACVIA/ACVIBA ECVIA/CCVIA – ECVIBA/CCVIBA

• Cooling capacities up to 30 kW

• EER/COP coefficient ranging

from 2.9 in nominal temperature conditions

• Scroll Compressors with soft-start

• R410a refrigerant

• DC inverter technology: maximum savings and comfort

• Low sound level

• High performance in heat pump for low outdoor temperatures as low as -15°C

MAIN FEATURESThis range of units are self-contained vertical units suitable for connection to both indoor and outdoor sections of a network of air distribution ducts. Designed to be installed inside the building to be air-conditioned, they are characterised by offering great flexibility in the installation.

• Operating limit in cooling mode with outdoor temperature of 48°C

• Soft-start of the indoor and/or

outdoor fan

• Oil separator (only in split units)

• ON/OFF remote

• Remote cooling/heating

• Scheduling function and Modbus connection

• Controls supplied as standard TH Tune

COMPACT/SPLIT VERTICAL INVERTER

ACVIACooling only

ECVIA/CCVIA Cooling only

ACVIBAHeat pump

ECVIBA/CCVIBA Heat pump

COMPACT configuration SPLIT configuration

SELF-CONTAINED AIR-TO-AIR UNITS

Inverter High Energy Efficiency at the service of energy rehabilitation in the commercial sector

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

Page 13: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

12

A01

ACVIA-ACVIBA TECHNICAL SPECIFICATIONS

MODEL 601 741 901

Maximum cooling capacity (120 Hz) kW 18.5 23.9 28.3Maximum cooling capacity (120 Hz) R.T. 5.3 6.8 8.1Maximum heating capacity (120 Hz) kW 20.0 26.1 30.6Nominal cooling capacity (80 Hz) kW 13.8 17.7 22.0Nominal cooling capacity (80 Hz) R.T. 3.9 5.0 6.3Nominal heating capacity (80 Hz) kW 14.0 18.0 22.5Maximum EER coefficient kW/kW 2.90 2.86 2.96Maximum COP coefficient kW/kW 2.95 2.94 2.99Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+NIndoor airflows m3/h 2700/3200/4000 3200/3800/4800 3900/4650/5900Max. int. airflow – static pressure m3/h – Pa 4000 – 70 4800 – 75 5900 – 90Max out. airflow – static pressure m3/h – Pa 6800 – 50 7300 – 50 10,000 – 50Dimensions (length x width x height) mm 1130x800x1900 1130x800x1900 1700x870x1900Net weight Kg 400 470 600

OUTDOOR UNIT (CCVIA/CCVIBA) TECHNICAL SPECIFICATIONS

MODEL 601 741 901

Maximum cooling capacity (120 Hz) kW 18.5 23.9 28.3Maximum cooling capacity (120 Hz) R.T. 5.3 6.8 8.1Maximum heating capacity (120 Hz) kW 20.0 26.1 30.6Nominal cooling capacity (80 Hz) kW 13.8 17.7 22.0Nominal cooling capacity (80 Hz) R.T. 3.9 5.0 6.3Nominal heating capacity (80 Hz) kW 14.0 18.0 22.5Maximum EER coefficient kW/kW 2.90 2.86 2.96Maximum COP coefficient kW/kW 2.95 2.94 2.99Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+NCooling connect. Liquid line Ø (") 1/2 5/8 5/8Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8Max out. airflow – static pressure m3/h – Pa 6800 – 50 7300 – 50 10,000 – 50Dimensions (length x width x height) mm 1130x800x1250 1130x800x1250 1700x870x1250Net weight Kg 260 320 390

INDOOR UNIT (ECVIA/ECVIBA) TECHNICAL SPECIFICATIONS

MODEL 601 741 901

Maximum cooling capacity (120 Hz) kW 18.5 23.9 28.3Maximum cooling capacity (120 Hz) R.T. 5.3 6.8 8.1Maximum heating capacity (120 Hz) kW 20.0 26.1 30.6Nominal cooling capacity (80 Hz) kW 13.8 17.7 22.0Nominal cooling capacity (80 Hz) R.T. 3.9 5.0 6.3Nominal heating capacity (80 Hz) kW 14.0 18.0 22.5Maximum EER coefficient kW/kW 2.90 2.86 2.96Maximum COP coefficient kW/kW 2.95 2.94 2.99Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+NCooling connect. Liquid line Ø (") 1/2 5/8 5/8Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8Indoor airflows m3/h 2700/3200/4000 3200/3800/4800 3900/4650/5900Max. int. airflow – static pressure m3/h – Pa 4000 – 70 4800 – 75 5900 – 90Dimensions (length x width x height) mm 1130x800x650 1130x800x650 1700x870x650Net weight Kg 140 150 210

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 14: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

13

A01

12,500

10,500

8,500

6,500

4,500

0 3 6 9 12 15 18 21 24 27 30 33 3619

PAYBACK STUDY

Comparative study and calculation of the payback period for replacing the existing unit with a fixed speed unit or an inverter unit in the banking sector. This corresponds to a standard office in the Madrid climatic area. Estimated calculation based on the entry of data provided by the customer.

HITECSA offers you its Technical Departmentto make estimated calculations for replacing your units.

Inve

rter

vs

On-

Off

Cos

ts (€

)

Payback times – months

PRODUCTRECOMMENDED

FOR ENERGY REHABILITATION

ENERGY SAVINGOption of mixing module for free cooling with three dampers

AIR QUALITYGravimetric filter in return G4 Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVELDouble thermo-acoustic insulationCompressor sound jacket

UNIT INSTALLATIONOption of manufacturing units with symmetric configurationOutdoor installation kitUpgraded motors

Anti-freeze heater for condenser in trayFireproof filter class M0 Hot water heating coils Electrical heating as backup in defrostingAnti-corrosion pre-treated coilsPrepared for disassembly Only for SPLIT configuration:

Quick-connect valves with preload of refrigerant gas

MAINTENANCE

Service valvesClogged filter indicationCondenser filterSplit filter

REGULATION AND CONTROLAlarm indicationSmoke detectionSeparate electrical panelAmbient temperature or wall mounted sensorDischarge temperature sensorCentralised integrated management operation

Operation without neutral

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

ON-OFFINVERTER

Page 15: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

14

ECHA/CCHA – ECHBA/CCHBA

A02

ACHA/ACHBA

ACHA/ACHBA

ECHA/CCHA – ECHBA/CCHBA

201, 501 701, 721, 751, 801 1001, 1201

ECHA/ECHBA 251, 1201 CCHA/CCHBA 701, 721, 751, 801 CCHA/CCHBA 1001, 1201CCHA/CCHBA 201, 251, 351, 371, 501

COMPACT/SPLIT HORIZONTAL ON-OFF

ACHACooling only

ECHA/CCHACooling only

ACHBAHeat pump

ECHBA/CCHBAHeat pump

COMPACT configuration SPLIT configuration

SELF-CONTAINED AIR-TO-AIR UNITS

• Cooling capacities ranging from 5.6 to 33.5 kW

• Scroll Compressors

• R410a refrigerant

• Can be combined with the RCAH range of heat recovery units of high energy efficiency and filters up to F Class.

MAIN FEATURESThis range of units are self-contained horizontal units suitable for connection to both indoor and outdoor sections of a network of air distribution ducts.

Designed to be installed inside the building to be air-conditioned, they are characterised by offering great flexibility in the installation.

• Thermostats and controls supplied as standard for units with electromagnetic regulation

RTR 7035 model 201T-8376B models 251-501 SUPER SI models 701-1201

Maximum flexibility for air conditioning through ducts of commercial premises

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

Page 16: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

15

A02

MODEL 201 251 351 371 401 501

Nominal cooling capacity kW 5.6 7.4 9.7 11.6 12.4 14.1

Nominal cooling capacity R.T. 1.6 2.1 2.8 3.3 3.5 4.0

Nominal heating capacity kW 6.1 8.2 9.8 12 13.8 16.4

Total power input – cooling kW 2.8 3.3 4.3 4.9 5.1 6.5

Total power input – heating kW 2.6 3.1 3.8 4.4 4.6 5.9

Power supply (50 Hz ~) V 230.1 230.1-400.3+N 230.1-400.3+N 400.3+N 400.3+N 400.3+N

Airflow – in. static pressure m3/h – Pa 1500 – 37 1600 – 47 2000 – 37 2700 – 32 2700 – 32 3200 – 48

Airflow – out. static pressure m3/h – Pa 2100 – 50 2450 – 50 3180 – 50 3800 – 50 3800 – 50 4150 – 50

Dimensions (length x width x height) mm 1175x1109x452 1325x1259x504 1445x1339x504 1505x1389x562 1505x1389x562 1505x1389x562

Net weight Kg 159 197 219 253 253 260

MODEL 701 721 751 801 1001 1201

Nominal cooling capacity kW 17.2 18.5 20.8 21.9 28.4 33.5

Nominal cooling capacity R.T. 4.9 5.3 5.9 6.2 8.1 9.5

Nominal heating capacity kW 18.9 20.4 21.9 24.6 29.8 37.2

Total power input – cooling kW 7.8 8.5 9.5 9.7 12.4 15.7

Total power input – heating kW 6.9 7.9 8.1 8.8 11.8 15.1

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Airflow – in. static pressure m3/h – Pa 4300 – 50 4300 – 50 4300 – 50 4300 – 50 5900 – 50 7550 – 82

Airflow – out. static pressure m3/h – Pa 5600 – 50 5600 – 50 5700 – 50 6200 – 50 7600 – 50 9900 – 90

Dimensions (length x width x height) mm 1755x1697x640 1755x1697x640 1755x1697x640 1755x1697x640 1998x1755x672 2400x2201x782

Net weight Kg 354 354 395 404 476 633

ACHA/ACHBA TECHNICAL SPECIFICATIONS

MODEL 701 721 751 801 1001 1201

Nominal cooling capacity kW 17.2 18.5 20.8 21.9 28.4 33.5

Nominal cooling capacity R.T. 4.9 5.3 5.9 6.2 8.1 9.5

Nominal heating capacity kW 18.9 20.4 21.9 24.6 29.8 37.2

Total power input – cooling kW 6.7 7.4 8.3 8.5 11.1 13.6

Total power input – heating kW 5.7 6.7 7 7.4 10.2 12.2

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 1/2" 1/2" 5/8" 5/8" 5/8" 5/8"

Cooling connect. Gas line Ø (") 7/8" 7/8" 7/8" 7/8" 1 1/8" 1 1/8"

Airflow – out. static pressure m3/h – Pa 5600 – 50 5600 – 50 5700 – 50 6200 – 50 7600 – 50 9900 – 90

Dimensions (length x width x height) mm 1755x1004x640 1755x1004x640 1755x1004x640 1755x1004x640 1750x1057x662 2300x1382x782

Net weight Kg 223 223 263 272 292 410

MODEL 201 251 351 371 401 501

Nominal cooling capacity kW 5.6 7.4 9.7 11.6 12.4 14.1

Nominal cooling capacity R.T. 1.6 2.1 2.8 3.3 3.5 4.0

Nominal heating capacity kW 6.1 8.2 9.8 12 13.8 16.4

Total power input – cooling kW 2.5 3.0 3.9 4.3 4.5 5.6

Total power input – heating kW 2.3 2.9 3.4 3.8 4.0 4.9

Power supply (50 Hz ~) V 230.1 230.1 – 400.3+N 230.1 – 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 3/8" 3/8" 3/8" 1/2" 1/2" 1/2"

Cooling connect. Gas line Ø (") 1/2" 5/8" 3/4" 7/8" 7/8" 7/8"

Airflow – out. static pressure m3/h – Pa 2100 – 50 2450 – 50 3180 – 50 3800 – 50 3800 – 50 4150 – 50

Dimensions (length x width x height) mm 1175x619x452 1325x706x504 1405x825x504 1455x843x562 1455x843x562 1455x843x562

Net weight Kg 106 133 146 172 172 172

OUTDOOR UNIT (CCHA/CCHBA) TECHNICAL SPECIFICATIONS

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 17: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

16

A02

MODEL 201 251 351 371 401 501

Nominal cooling capacity kW 5.6 7.4 9.7 11.6 12.4 14.1

Nominal cooling capacity R.T. 1.6 2.1 2.8 3.3 3.5 4.0

Nominal heating capacity kW 6.1 8.2 9.8 12 13.8 16.4

Total power input – cooling kW 0.15 0.23 0.3 0.4 0.4 0.7

Total power input – heating kW 0.15 0.23 0.3 0.4 0.4 0.7

Airflow – static pressure m3/h – Pa 1500 – 37 1600 – 47 2000 – 37 2700 – 32 2700 – 32 3200 – 48

Power supply (50 Hz ~) V 230.1 – 400.3+N 230.1 230.1 230.1 230.1 – 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 1/2" 3/8" 3/8" 1/2" 1/2" 1/2"

Cooling connect. Gas line Ø (") 3/8" 5/8" 3/4" 7/8" 7/8" 7/8"

Dimensions (length x width x height) mm 1175x562x452 1325x600x504 1405x600x504 1455x642x562 1455x642x562 1455x642x562

Net weight Kg 61 72 81 89 89 96

MODEL 701 721 751 801 1001 1201

Nominal cooling capacity kW 17.2 18.5 20.8 21.9 28.4 33.5

Nominal cooling capacity R.T. 4.9 5.3 5.9 6.2 8.1 9.5

Nominal heating capacity kW 18.9 20.4 21.9 24.6 29.8 37.2

Total power input – cooling kW 0.9 0.9 0.9 1.3 1.6 2.7

Total power input – heating kW 0.8 0.9 0.9 1.1 1.3 2.1

Airflow – static pressure m3/h – Pa 4300 – 50 4300 – 50 4300 – 50 4300 – 50 5900 – 50 7550 – 82

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 1/2" 1/2" 5/8" 5/8" 5/8" 5/8"

Cooling connect. Gas line Ø (") 7/8" 7/8" 7/8" 7/8" 1 1/8" 1 1/8"

Dimensions (length x width x height) mm 1775x752x640 1755x752x640 1755x752x640 1755x752x640 1750x900x662 2300x925x782

Net weight Kg 136 136 137 137 172 209

INDOOR UNIT (ECHA/ECHBA) TECHNICAL SPECIFICATIONS

ENERGY SAVINGOption of mixing module for free cooling with two or three dampers Thermal or enthalpy regulation with PCO control card and PGD controlHead pressure control by frequency converter or voltage converterCompressor soft-start (depending on models)Soft-start of the indoor and/or outdoor fan (depending on models)

AIR QUALITYGravimetric filter in return G4 Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVELDouble thermo-acoustic insulationCompressor sound jacket

UNIT INSTALLATIONMagnetothermics in electrical panelPower supply at 60Hzand voltages 230, 208, etc.Option of manufacturing units with symmetric configurationOutdoor installation kitUpgraded motors

Anti-freeze resistanceoperation in collection trayFireproof filter class M0Hot gas bypassHot water heating coils Electric resistance coils for auxiliary electric heatingAnti-corrosion pre-treated coilsR407C refrigerant models available on requestPrepared for disassemblyOnly for SPLIT configuration:

Oil separator Service valves Quick-connect valveswith preload of refrigerant gas

MAINTENANCE

Service valves

External Schrader valves for pressure test

Clogged filter indication

Condenser filter

Split filter

REGULATION AND CONTROLETN thermostat ARIA thermostat SUPER SI thermostat (man. 24 V)

PGD thermostat DSX@ thermostat (man. 24 V)Alarm indicationSmoke detectionON/OFF remoteSeparate electrical panelOption of master-slave operation High pressure switch resetfrom thermostatUnit without thermostatWall mounted ambienttemperature sensorReturn temperature sensorTemperature sensor in ductOperation for redundant machineCentralised integrated management operationOperation without neutralScheduling function and Modbus connection, etc. consult

Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 18: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

17

A02

CCHA/CCHBA 701, 721CCHA/CCHBA 201, 251, 351, 371, 501

CCHA/CCHBA FTA/FTBA

SELF-CONTAINED AIR-TO-AIR UNITS

CCHA/FTA Cooling only

CCHBA/FTBA Heat pump

Self-contained ductable split systems consisting of a centrifugal condenser unit

• Cooling capacities ranging from 5.2 to 19.3 kW

• Outdoor units with standard blue fin pre-treated coils

• 3-speed indoor fan • Maximum connection distances

between indoor and outdoor units of 50 metres.

MAIN FEATURESThe units in the CCHA/FTA and CCHBA/FTBA series are sets comprising a centrifugal condenser unit and a direct expansion fan coil evaporator unit.

The reduced height of the indoor units make them ideal for fast installation in false ceilings, with the unit either supported or suspended.

DUCTABLE SPLIT

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

Maximum flexibility for air conditioning through ducts of commercial premises

• Thermostats and controls supplied as standard for units with electromagnetic regulation

RTR 7007 (depending on models)T-8376B (depending on models) SUPER SI (depending on models)

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 19: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

18

A02 CCHBA/FTBA TECHNICAL SPECIFICATIONS

CCHA/FTA

OUTDOOR MODEL 201 251 351 371

INDOOR MODEL 201 251 351 371

Nominal cooling capacity kW 5.2 7.4 9.6 10.4

Nominal cooling capacity R.T. 1.5 2.1 2.7 3.0

Nominal heating capacity kW 5.8 7.8 10.2 11.0

Total power input – cooling kW 2.7 3.2 4.24 4.68

Total power input – heating kW 2.5 3.1 3.74 4.18

Power supply (50 Hz ~) V 230.1 230.1 or 400.3+N 230.1-230.3 or 400.3+N 230.1-230.3 or 400.3+N

Airflow – static pressure (in.) m3/h – Pa 1100 – 44 1150 – 72 1500 – 80 2200 – 96

Airflow – static pressure (out.) m3/h – Pa 2100 – 50 2450 – 50 3180 – 50 3800 – 50

Liq. pipe diameter Ø (") 3/8 3/8 3/8 1/2

Gas pipe diameter Ø (") 1/2 5/8 3/4 3/4 (in.)- 7/8 (out.)

Ext. dimens. (length x width x height) mm 1175x619x452 1325x706x504 1405x825x504 1455x843x562

Int. dimens. (length x width x height) mm 925x660x280 925x660x280 925x660x280 1250x750x315

Total dist. in./out. units m 50 50 50 50

Vertical dist in./out. units m 25 25 25 25

Net weight – outdoor Kg 106 133 146 172

Net weight – indoor Kg 37 39 44 59

OUTDOOR MODEL 401 501 701 721

INDOOR MODEL 401 501 721 721

Nominal cooling capacity kW 11.8 14.5 18.0 19.3

Nominal cooling capacity R.T. 3.4 4.1 5.1 5.5

Nominal heating capacity kW 12.5 15.3 19.8 20.6

Total power input – cooling kW 4.94 6.13 7.9 8.6

Total power input – heating kW 4.44 5.43 6.9 7.9

Power supply (50 Hz ~) V 230.3 or 400.3 +N 230.3 or 400.3 +N 400.3+N 230.3 or 400.3 +N

Airflow – static pressure (in.) m3/h – Pa 2300 – 80 2500 – 76 3000 – 140 3000 – 140

Airflow – static pressure (out.) m3/h – Pa 3800 – 50 4150 – 50 5600 – 50 5600 – 50

Liq. pipe diameter Ø (") 1/2 1/2 1/2 1/2

Gas pipe diameter Ø (") 3/4 (in.)- 7/8 (out.) 7/8 7/8 7/8

Ext. dimens. (length x width x height) mm 1455x843x562 1455x843x562 1755x1004x640 1755x1004x640

Int. dimens. (length x width x height) mm 1250x750x315 1250x750x315 1250x805x369 1250x805x369

Total dist. in./out. units m 50 50 50 50

Vertical dist. in./out. units m 25 25 25 25

Net weight – outdoor Kg 172 172 223 223

Net weight – indoor Kg 59 61 71 71

Voltage for indoor unit 230.1 50 Hz ~

For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 20: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

19

A02

ENERGY SAVING

Compressor soft-start(depending on models)

Head pressure control by frequency converter or voltage converter

AIR QUALITY

Gravimetric filter in return G4

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Side intake and discharge(outdoor unit)

Option of manufacturingunits with symmetric configuration (outdoor unit)

Connections on rear side.(outdoor unit)

Indoor unit equipment and accessories painted in RAL 1013 polyester powder coating

Outdoor installation kit

Upgraded motors

Anti-freeze heater for collection tray

Fireproof filter class M0

Hot gas bypass

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

R407C refrigerant models available on request

Prepared for disassembly

Only for SPLIT configuration:

Oil separator

Service valves

Quick-connect valveswith preload of refrigerant gas

Discharge plenum and return

Grille discharge plenum and return

3 and 5 outlet nozzle plenum

Condensate evacuation pump

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Condenser filter

Split filter

REGULATION AND CONTROL

Pressure switches

Electromagnetic regulation

Infrared remote control

ARIA thermostat

PGD thermostat

ETN thermostat

DSX@ thermostat (man. 24 V)

SUPER SI thermostat (man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Stopping of the evaporatorfan in the defrosting

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus

connection, etc. consultThermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 21: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

20

ACVA/ACVBA ECVA/CCVA – ECVBA/CCVBA

A02

ACVA/ACVBA ECVA/CCVA – ECVBA/CCVBA

CCVA-CCVBA 351, 3002 CCVA-CCVBA 3502ECVA-ECVBA 351, 3502

SELF-CONTAINED AIR-TO-AIR UNITS

ACVACooling only

ECVA/CCVACooling only

ACVBAHeat pump

ECVBA/CCVBAHeat pump

COMPACT configuration SPLIT configuration

• Cooling capacities ranging from 9.8 to 114.3 kW

• Scroll Compressors

• R410a refrigerant

• 2 separate refrigerated circuits (models from 1402 to 3502)

• Option of operating as 2x1 multisplit set (models 1402 to 3002)

• Two indoor units connected to an outdoor unit (operation with one or two thermostats)

• One indoor unit connected to two outdoor units (operation with only one thermostat)

MAIN FEATURESThis range of units are self-contained vertical units suitable for connection to both indoor and outdoor sections of a network of air distribution ducts.

Designed to be installed inside the building to be air-conditioned, they are characterised by offering great flexibility in the installation.

• Refrigerated distance between indoor and outdoor unit (Split config.) of up to 50 m in total

• Can be combined with the RCAH range of heat recovery units of high energy efficiency and filters up to F Class.

• Thermostats and controls suppliedas standard for units with electromagnetic regulation

T-8376B- models 351-501 SUPER SI- models 701-3502

COMPACT/SPLIT VERTICAL ON-OFFMaximum flexibility for air conditioning through ducts of commercial premises

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 22: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

21

A02ACVA/ACVBA TECHNICAL SPECIFICATIONS

MODEL 351 401 501 701 721 751

Nominal cooling capacity kW 9.8 12.5 14.4 18.9 19.6 22.7

Nominal cooling capacity R.T. 2.8 3.6 4.1 5.4 5.6 6.5

Nominal heating capacity kW 10.4 13.7 15.0 20.0 21.0 23.9

Total power input – cooling kW 4.6 5.6 7.2 8.4 9.3 10.9

Total power input – heating kW 4.2 5.1 6.5 7.9 8.2 10.3

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Airflow – in. static pressure m3/h – Pa 2315-43 2600-50 3540-60 4720-55 4720-55 5133-53

Airflow – out. static pressure m3/h – Pa 4300-50 3950-50 4900-50 6800-50 6800-50 7400-50

Dimensions (length x width x height) mm 937x750x1604 937x750x1604 1087x750x1604 1130x800x1900 1130x800x1900 1130x800x1900

Net weight Kg 251 276 290 367 392 423

MODEL 801 1001 1201 1402 1502 1602

Nominal cooling capacity kW 24.2 30.1 34.9 37.8 43.4 50.2

Nominal cooling capacity R.T. 6.9 8.6 9.9 10.7 12.3 14.3

Nominal heating capacity kW 25.3 31.7 38.2 39.5 44.2 51.9

Total power input – cooling kW 10.9 13.4 14.4 16.2 17.6 20.1

Total power input – heating kW 9.6 12.4 13.2 15.5 16.5 18.0

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Airflow – in. static pressure m3/h – Pa 5150-83 6200-73 8000-91 8000-130 10000-145 10000-145

Airflow – out. static pressure m3/h – Pa 7714-57 10000-50 12500-50 13600-88 15600-110 16000-110

Dimensions (length x width x height) mm 1130x800x1900 1700x870x1900 1700x870x1900 2000x939x1997 2000x939x1997 2000x939x1997

Net weight Kg 440 553 558 730 810 820

MODEL 2002 2302 2402

Nominal cooling capacity kW 63.1 73.6 78.5

Nominal cooling capacity R.T. 17.9 20.9 22.3

Nominal heating capacity kW 65.5 81.9 81.9

Total power input – cooling kW 26.0 28.7 34.3

Total power input – heating kW 22.8 27.5 29.0

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N

Airflow – in. static pressure m3/h – Pa 11000-175 12000-160 12000-160

Airflow – out. static pressure m3/h – Pa 22000-123 23000-142 23000-142

Dimensions (length x width x height) mm 2600x980x2174 2600x980x2174 2600x980x2174

Net weight Kg 1080 1115 1135

OUTDOOR UNIT (CCVA/CCVBA) TECHNICAL SPECIFICATIONS

MODEL 351 401 501 701 721 751

Nominal cooling capacity kW 9.8 12.5 14.4 18.9 19.6 22.7

Nominal cooling capacity R.T. 2.8 3.6 4.1 5.4 5.6 6.5

Nominal heating capacity kW 10.4 13.7 15.0 20.0 21.0 23.9

Total power input – cooling kW 4.0 5.1 6.4 7.3 8.0 9.4

Total power input – heating kW 3.7 4.5 5.5 6.8 7.0 9.0

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 3/8 1/2 1/2 1/2 1/2 5/8

Cooling connect. Gas line Ø (") 3/4 3/4 7/8 7/8 7/8 7/8

Airflow – out. static pressure m3/h – Pa 4300-50 3950-50 4900-50 6800-50 6800-50 7400-50

Dimensions (length x width x height) mm 937x750x1022 937x750x1022 1087x750x1022 1130x800x1250 1130x800x1250 1130x800x1250

Net weight Kg 172 189 200 253 272 297

MODEL 801 1001 1201 1402 1502 1602

Nominal cooling capacity kW 24.2 30.1 34.9 37.8 43.4 50.2

Nominal cooling capacity R.T. 6.9 8.6 9.9 10.7 12.3 14.3

Nominal heating capacity kW 25.3 31.7 38.2 39.5 44.2 51.9

Total power input – cooling kW 9.4 12.0 12.5 13.9 15.2 14.4

Total power input – heating kW 8.3 11.0 11.5 14.9 14.6 16.5

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 5/8 5/8 5/8 1/2 5/8 5/8

Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8 7/8 7/8 1 1/8

Airflow – out. static pressure m3/h – Pa 7714-57 10000-50 12500-50 13600-88 15600-110 16000-110

Dimensions (length x width x height) mm 1130x800x1250 1700x870x1250 1700x870x1250 2000x939x1250 2000x939x1250 2000x939x1250

Net weight Kg 304 373 397 477 538 548

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 23: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

22

A02

OUTDOOR UNIT (CCVA/CCVBA) TECHNICAL SPECIFICATIONS

MODEL 2002 2302 2402 3002 3502

Nominal cooling capacity kW 63.1 73.6 78.5 86.6 114.3

Nominal cooling capacity R.T. 17.9 20.9 22.3 24.6 32.5

Nominal heating capacity kW 65.5 81.9 81.9 88.8 119.6

Total power input – cooling kW 21.6 23.4 24.2 31.1 39.8

Total power input – heating kW 21.7 25.7 25.5 27.4 32.3

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 5/8 5/8 5/8 5/8 7/8

Cooling connect. Gas line Ø (") 1 1/8 1 1/8 1 1/8 1 3/8 1 5/8

Airflow – out. static pressure m3/h – Pa 22000-123 23000-142 23000-142 27000-140 32000-160

Dimensions (length x width x height) mm 2600x980x1422 2600x980x1422 2600x980x1422 2800x1050x1722 2800x1050x1722

Net weight Kg 747 782 802 978 1058

INDOOR UNIT (ECVA/ECVBA) TECHNICAL SPECIFICATIONS

MODEL 351 401 501 701 721 751

Nominal cooling capacity kW 9.8 12.5 14.4 18.9 19.6 22.7

Nominal cooling capacity R.T. 2.8 3.6 4.1 5.4 5.6 6.5

Nominal heating capacity kW 10.4 13.7 15.0 20.0 21.0 23.9

Total power input – cooling kW 0.3 0.4 0.9 1.0 0.9 1.1

Total power input – heating kW 0.3 0.4 0.8 0.9 0.9 1.0

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 3/8 1/2 1/2 1/2 1/2 5/8

Cooling connect. Gas line Ø (") 3/4 3/4 7/8 7/8 7/8 7/8

Airflow – static pressure m3/h – Pa 2315-43 2600-50 3540-60 4720-55 4720-55 5133-53

Dimensions (length x width x height) mm 937x750x582 937x750x582 1087x750x582 1130x800x650 1130x800x650 1130x800x650

Net weight Kg 92 95 99 126 126 136

MODEL 801 1001 1201 1402 1502 1602

Nominal cooling capacity kW 24.2 30.1 34.9 37.8 43.4 50.2

Nominal cooling capacity R.T. 6.9 8.6 9.9 10.7 12.3 14.3

Nominal heating capacity kW 25.3 31.7 38.2 39.5 44.2 51.9

Total power input – cooling kW 1.0 1.0 1.3 2.2 2.2 2.3

Total power input – heating kW 1.0 0.9 1.2 1.7 1.7 1.9

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 5/8 5/8 5/8 1/2 5/8 5/8

Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8 7/8 7/8 1 1/8

Airflow – static pressure m3/h – Pa 5125-83 6277-73 8000-91 8000-130 10000-145 10000-145

Dimensions (length x width x height) mm 1130x800x650 1700x870x650 1700x870x650 2000x939x747 2000x939x747 2000x939x747

Net weight Kg 136 197 199 253 272 272

MODEL 2002 2302 2402 3002 3502

Nominal cooling capacity kW 63.1 73.6 78.5 86.6 114.3

Nominal cooling capacity R.T. 17.9 20.9 22.3 24.6 32.5

Nominal heating capacity kW 65.5 81.9 81.9 88.8 119.6

Total power input – cooling kW 3.1 3.3 3.6 3.9 3.9

Total power input – heating kW 2.7 2.4 2.9 2.3 2.3

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 5/8 5/8 5/8 5/8 7/8

Cooling connect. Gas line Ø (") 1 1/8 1 1/8 1 1/8 1 3/8 1 5/8

Airflow – static pressure m3/h – Pa 11000-175 12000-160 12000-160 14000-200 18000-250

Dimensions (length x width x height) mm 2600x980x752 2600x980x752 2600x980x752 2800x1050x915 2800x1050x915

Net weight Kg 333 333 333 418 524

For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 24: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

23

A02

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start(depending on models)

Soft-start ofindoor and/or outdoor fan(depending on models)

Head pressure control by frequency converter or voltage converter

EC radial indoor fan(depending on models)

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulationCompressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Option of manufacturingunits with symmetric configuration

Outdoor installation kit

Upgraded motors

Anti-freeze heater for collection tray

Fireproof filter class M0

Hot gas bypass

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

R407C refrigerant models available on request

Prepared for disassembly

Only for SPLIT configuration:

Oil separator

Service valves

Quick-connect valveswith preload of refrigerant gas

2x1 multisplit operation(1402 to 2402)

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Condenser filter

Split filter

REGULATION AND CONTROL

ETN thermostat (mod. 1 circuit)

ARIA thermostat

SUPER SI thermostat (man. 24 V)

PGD thermostat DSX@ thermostat (man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult

Thermostat chapter.

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 25: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

24

UXCA/UXCBA ECVA/ECVBA

A03/1

SELF-CONTAINED AIR-TO-AIR UNITS

UXCA/ECVA Cooling only

UXCBA/ECVBA Heat pump

• Cooling capacities ranging from 23.6 to 139.7 kW

• Scroll compressors

• 2 separate refrigerated circuits (models from 1602 to 4502)

• Can be combined with the RCAH range of heat recovery units of high energy efficiency and filters up to F Class.

• 3 versions available:Standard (STD)LOW SOUND LEVEL (SIL)Special High Ambient

Temperatures (ATA)

MAIN FEATURESThe units in the UXCA/ECVA – UXCBA/ECVBA series are split units that are especially suitable for installation on rooftops, terraces or in other outdoor areas.

Their design allows large distances in the installation between outdoor and indoor units.

• Refrigerated distance between outdoor and indoor unit up to 50 m in total

• Option of operating as a set multisplit 2x1 (models 1602 to 3002)

• Two indoor units connected to an outdoor unit (operation with one or two thermostats)

• One indoor unit connected to two outdoor units (operation with only one thermostat)

• Thermostats and controls supplied as standard for units with electromagnetic regulationSUPER SI- (man. 24V)

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SELF-CONTAINED SPLIT AXIAL FANMaximum flexibility for air conditioning through ducts of commercial premises

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 26: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

25

A03/1

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

OUTDOOR UNIT (UXCA/UXCBA) TECHNICAL SPECIFICATIONS

INDOOR UNIT (ECVA/ECVBA) TECHNICAL SPECIFICATIONS

MODEL 801 1001 1201 1501 1602 2002

Nominal cooling capacity kW 23.6 29.7 34.5 40.3 49.6 65.3

Nominal cooling capacity R.T. 6.7 8.4 9.8 11.5 14.1 18.6

Nominal heating capacity kW 24.9 30.6 39.6 41.6 52.4 67.6

Total power input – cooling kW 10.1 12.0 14.0 15.5 19.5 23.0

Total power input – heating kW 9.9 11.1 14.2 14.7 18.3 21.3

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Dimensions (length x width x height) mm 1430x1008x325 1430x1008x1325 1400x1320x1500 1400x1320x1500 2035x1030x1325 2035x1030x1325

Net weight Kg 251 316 382 392 495 545

MODEL 801 1001 1201 1501 1602 2002

Nominal cooling capacity kW 23.6 29.7 34.5 40.3 49.6 65.3

Nominal cooling capacity R.T. 6.7 8.4 9.8 11.5 14.1 18.6

Nominal heating capacity kW 24.9 30.6 39.6 41.6 52.4 67.6

Total power input – cooling kW 1.5 1.4 1.9 2.6 2.4 2.6

Total power input – heating kW 1.5 1.3 1.7 2.4 2.3 2.5

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 5/8 5/8 5/8 5/8 5/8 5/8

Cooling connect. Gas line Ø (") 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8

Airflow – static pressure m3/h – Pa 5150-83 6200-73 8000-91 9000-130 10000-145 11000-175

Dimensions (length x width x height) mm 1130x800x650 1700x870x650 1700x870x650 2000x939x747 2000x939x747 2600x980x752

Net weight Kg 136 197 199 272 272 333

MODEL 2402 3002 4002 4502

Nominal cooling capacity kW 73.1 89.4 122.9 139.7

Nominal cooling capacity R.T. 20.8 25.4 34.9 39.7

Nominal heating capacity kW 78.3 86.0 124.8 144.2

Total power input – cooling kW 24.4 29.6 40.7 46.3

Total power input – heating kW 24.7 30.7 38.4 42.3

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N

Dimensions (length x width x height) mm 2280x1320x1500 2720x1320x1500 2200x2250x1725 2200x2250x1725

Net weight Kg 567 894 950 992

MODEL 2402 3002 4002 4502

Nominal cooling capacity kW 73.1 89.4 122.9 139.7

Nominal cooling capacity R.T. 20.8 25.4 34.9 39.7

Nominal heating capacity kW 78.3 86 124.8 144.2

Total power input – cooling kW 2.6 3.3 5.6 6.2

Total power input – heating kW 2.5 3.6 5.5 5.4

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N

Cooling connect. Liquid line Ø (") 5/8 5/8 7/8 7/8

Cooling connect. Gas line Ø (") 1 1/8 1 3/8 1 5/8 1 5/8

Airflow – out. static pressure m3/h – Pa 12000-160 14000-200 20500-210 22000-200

Dimensions (length x width x height) mm 2600x980x752 2800x1050x915 2900x1200x1115 2900x1200x1115

Net weight Kg 333 418 550 570

For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department

Page 27: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

26

A03/2

SELF-CONTAINED AIR-TO-AIR UNITS

CLVACooling only

CLVBAHeat pump

INDOOR UNITS FOR CONNECTIONTO VERTICAL DUCTS

The units of the CLVA/CLVBA series are direct expansion evaporator units suitable for connection to a network of air distribution ducts. These units are designed to work together with any Hitecsa outdoor unit of an equivalent cooling capacity. All models have the option to operate on direct discharge by means of an optional air discharge plenum equipped with an anodised aluminium grille for direct discharge.

• Airflows up to 10,200 m3/h

• Countless installation possibilities

• Connectable to any Hitecsa condensing unit

MAIN FEATURES

Maximum flexibility for air conditioning through ducts of commercial premises

CLVA/CLVBA TECHNICAL SPECIFICATIONS

MODEL 251 351 401 501 701 721

Nominal cooling capacity kW 7.4 9.8 12.0 14.4 18.2 22.1

Nominal cooling capacity R.T. 2.1 2.8 3.4 4.1 5.2 6.3

Nominal heating capacity kW 7.4 10.4 12.7 15.5 19.3 23.5

Total power input kW 0.3 0.4 0.6 0.6 0.9 0.9

Power supply (50 Hz ~) V 230.1 230.1 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N

Airflow – static pressure m3/h – Pa 1900-38 2500-68 3000-56 3400-100 4200-115 4400-109

Liquid pipe diameter Ø (") 3/8 3/8 1/2 1/2 1/2 1/2

Gas pipe diameter Ø (") 5/8 3/4 3/4 7/8 7/8 7/8

Dimensions (length x width x height) mm 697x500x1000 697x500x1000 697x500x1000 757x500x1100 1152x600x1200 1152x600x1200

Net weight Kg 45 69 73 94 118 118

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 28: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

27

A03/2

CLVA/CLVBA TECHNICAL SPECIFICATIONS

MODEL 751 801 1001 1201 1402 1502 1602

Nominal coolingcapacity kW 22.1 23.2 29.7 35.0 36.4 44.2 45.4

Nominal coolingcapacity R.T. 6.3 6.6 8.4 10.0 10.3 12.6 12.9

Nominal heatingcapacity kW 23.5 24.4 31.7 37.0 38.6 46.6 48.8

Total inputpower kW 1.3 1.3 1.3 1.8 1.8 2.6 2.6

Power supply(50 Hz ~) V 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N 230 or 400.3+N

Airflowstatic pressure m3/h – Pa 4800-120 5200-84 7200-78 8000-85 8400-72 9600-129 10200-123

Liquid pipe diameter Ø (") 5/8 5/8 5/8 5/8 2x1/2 2x5/8 2x5/8

Gas pipe diameter Ø (") 1 1/8 1 1/8 1 1/8 1 1/8 2x7/8 2x7/8 2x1 1/8

Dimensions(length x width x height)

mm 1152x600x1200 1152x600x1200 1700x600x1300 1700x600x1300 1800x675x1400 1800x675x1400 1800x675x1400

Net weight Kg 119 125 175 175 187 187 197

ENERGY SAVINGOption of mixing module for free cooling with two or three dampers Thermal or enthalpy regulation with PCO control card and PGD controlEC radial indoor fan(depending on models)Fan soft-start(depending on models)

AIR QUALITYGravimetric filter in return G4 Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVELDouble thermo-acoustic insulation

UNIT INSTALLATIONFront dischargePower supply at 60Hzand voltages 230, 208, etc.Outdoor installation kitUpgraded motorsFireproof filter class M0Hot gas bypassHot water heating coils (cooling only) Electric resistance coilsfor auxiliary electrical heating Return for insertionConnections opposite sideDischarge plenumIntake grille

Anti-corrosion pre-treated coilsR407C refrigerant models available on requestPrepared for disassembly Base guides

MAINTENANCEService valvesClogged filter indication

Split filter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

For sizing of refrigerated lines depending on layout and total installation distance consult our Commercial Department

Page 29: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

28

A03/2

ENERGY SAVING

Discharge fan in radial indoor unit with EC motor (depending on models)

Bionic profile condensation fan operated by EC or AC motor

Option of mixing module for free cooling with two or three dampers Thermal or enthalpy regulation with PCO control card and PGD controlCompressor soft-start (depending on models)Soft-start ofindoor and/or outdoor fan(depending on models)

Head pressure control by frequency converter or voltage converter

AIR QUALITY

Gravimetric filter in return G4 Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Low sound level EC fan

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panelPower supply at 60Hzand voltages 230, 208, etc.Option of manufacturingunits with symmetric configurationOutdoor installation kit(indoor unit)Upgraded motorsAnti-freeze heater for condenser in tray

Guides on the base (indoor unit)

New defrostsystem with pressuresFireproof filter class M0Hot gas bypassDouble speed or double speed by circuit condensation control (depending on models)

Coil protection grille(outdoor unit)

Hot water heating coil Electric resistance coils for auxiliary electric heatingAnti-corrosion pre-treated coilsR407C refrigerant models available on requestPrepared for disassembly

Only for SPLIT configuration:

Oil separator Service valves Quick-connect valveswith preload of refrigerant gas

2x1 multisplitoperation (1602/3002)

MAINTENANCE

Service valvesExternal Schrader valves for pressure testClogged filter indicationSplit filterPressure gauges

REGULATION AND CONTROLARIA thermostat PGD thermostat DSX@ thermostat (man. 24V)Alarm indicationSmoke detectionON/OFF remoteSeparate electrical panelHigh pressure switch resetfrom thermostatIndoor fanstop in defrostUnit without thermostatWall mounted ambienttemperature sensorReturn temperature sensorTemperature sensor in ductOperation for redundant machineCentralised integrated management operation

Operation without neutralScheduling function and Modbus connection, etc. consult

Thermostat chapter.Option of combining an outdoor unit and two indoor units with one indoor unit (only units with two circuits)

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Page 30: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

29

FTZ/FTBZDXCZ/DXCBZ

A03/3

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

AXIAL CONDENSER

DUCTABLE INDOOR UNITS ADVANCE

Maximum flexibility for air conditioning through ducts of commercial premises

DXCZCooling only

FTZCooling only

DXCBZHeat pump

FTBZHeat pump

SPLIT configuration

• Cooling capacities ranging from 4.7 to 19 kW

• Rotary compressors (models 171-351) and Scroll (371-721)

• Outdoor units with standard blue fin pre-treated coils

• 3-speed indoor fan

MAIN FEATURESThe units in the DXCZ/FTZ and DXCBZ/FTZ series are sets comprising an axial condenser unit and a direct expansion fan coil evaporator unit. The reduced height of the indoor units make them ideal for fast installation in false ceilings, with the unit either supported or suspended.

• Maximum connection distances between indoor and outdoor units of 50 metres.

• Quick-connect valves with preload of refrigerant gas for 5 metres

• Standard thermostats and controls with electromagnetic regulation

ETN

OUTDOOR MODEL 171 201 221 251 271 351

INDOOR MODEL 171 201 221 251 271 351

Nominal cooling capacity kW 4.7 5.3 6.3 7.0 7.7 9.8

Nominal cooling capacity R.T. 1.3 1.5 1.8 2.0 2.2 2.8

Total power input kW 1.9 2.1 2.7 3.0 3.0 3.9

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 or 400.3 230.1 or 400.3

Airflow – static pressure m3/h – Pa 700 – 32 1100 – 44 1100 – 44 1150 – 72 1400 – 96 1500 – 80

Liq. pipe diameter Ø (") 3/8 3/8 3/8 3/8 3/8 3/8

Gas pipe diameter Ø (") 1/2 1/2 1/2 5/8 3/4 3/4

Ext. dimens. (length x width x height) mm 870x394x630 870x394x630 870x394x630 870x394x630 920x394x730 920x394x730

Int. dimens. (length x width x height) mm 726x555x218 925x660x280 925x660x280 925x660x280 925x660x280 925x660x280

Total dist. in./out. units m 50 50 50 50 50 50

Vertical in./out. unit dist. (1) m 25 25 25 25 25 25

Net weight – outdoor Kg 50 53 53 54 58 63

Net weight – indoor Kg 31 37 37 39 43 44

DXCZ/FTZ TECHNICAL SPECIFICATIONS

1) For greater distances we recommend installing an oil separatorVoltage for indoor unit 230.1 Sortz

Page 31: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

30

A03/3

OUTDOOR MODEL 371 401 451 501 701 721

INDOOR MODEL 371 401 451 501 721 721

Nominal cooling capacity kW 11.0 11.8 13.5 14.8 17.2 19.0

Nominal cooling capacity R.T. 3.1 3.4 3.8 4.2 4.9 5.4

Total power input kW 4.3 4.6 5.4 5.7 7.3 7.8

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3

Airflow – static pressure m3/h – Pa 2200 – 96 2300 – 80 2400 – 94 2500 – 76 3000 – 140 3000 – 140

Liq. pipe diameter Ø (") 1/2 1/2 1/2 1/2 1/2 1/2

Gas pipe diameter Ø (") 3/4 3/4 7/8 7/8 7/8 7/8

Ext. dimens. (length x width x height) mm 950x374x1143 950x374x1143 950x374x1143 950x374x1143 950x374x1143 950x374x1143

Int. dimens. (length x width x height) mm 1250x750x315 1250x750x315 1250x750x315 1250x750x315 1250x805x369 1250x805x369

Total in./out. unit dist. (1) m 50 50 50 50 50 50

Vertical in./out. unit dist. (1) m 25 25 25 25 25 25

Net weight – outdoor Kg 82 82 101 101 115 120

Net weight – indoor Kg 59 59 61 61 71 71

1) For greater distances we recommend installing an oil separatorVoltage for indoor unit 230.1 Sortz

OUTDOOR MODEL 171 201 221 251 271 351

INDOOR MODEL 171 201 221 251 271 351

Nominal cooling capacity kW 4.7 5.3 6.3 7.0 7.7 9.8

Nominal cooling capacity R.T. 1.3 1.5 1.8 2.0 2.2 2.8

Nominal heating capacity kW 4.8 5.8 6.5 7.8 8.3 10.4

Total power input – cooling kW 1.9 2.1 2.7 3.0 3.0 3.9

Total power input – heating kW 1.9 2.0 2.3 2.6 2.6 3.7

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 or 400.3+N 230.1 or 400.3+N

Airflow – static pressure m3/h – Pa 700 – 32 1100 – 44 1100 – 44 1150 – 72 1400 – 96 1500 – 80

Liq. pipe diameter Ø (") 3/8 3/8 3/8 3/8 3/8 3/8

Gas pipe diameter Ø (") 1/2 1/2 1/2 5/8 3/4 3/4

Ext. dimens. (length x width x height) mm 870x394x630 870x394x630 870x394x630 870x394x630 920x394x730 920x394x730

Int. dimens. (length x width x height) mm 726x555x218 925x660x280 925x660x280 925x660x280 925x660x280 925x660x280

Total in./out. unit dist. (1) m 50 50 50 50 50 50

Vertical in./out. unit dist. (1) m 25 25 25 25 25 25

Net weight – outdoor Kg 53 56 56 58 62 68

Net weight – indoor Kg 31 37 37 39 43 44

DXCBZ/FTBZ TECHNICAL SPECIFICATIONS

OUTDOOR MODEL 371 401 451 501 701 721

INDOOR MODEL 371 401 451 501 721 721

Nominal cooling capacity kW 11.0 11.8 13.5 14.8 16.8 18.6

Nominal cooling capacity R.T. 3.1 3.4 3.8 4.2 4.8 5.3

Nominal heating capacity kW 12.0 12.8 14.0 15.3 19.8 20.7

Total power input – cooling kW 4.3 4.6 5.4 5.7 7.3 7.8

Total power input – heating kW 3.7 4.1 4.9 5.0 6.7 7.5

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Airflow – static pressure m3/h – Pa 2200 – 96 2300 – 80 2400 – 94 2500 – 76 3000 – 140 3000 – 140

Liq. pipe diameter Ø (") 1/2 1/2 1/2 1/2 1/2 1/2

Gas pipe diameter Ø (") 3/4 3/4 7/8 7/8 7/8 7/8

Ext. dimens. (length x width x height) mm 950x374x1143 950x374x1143 950x374x1143 950x374x1143 950x374x1143 1035x424x1335

Int. dimens. (length x width x height) mm 1250x750x315 1250x750x315 1250x750x315 1250x750x315 1250x805x369 1250x805x369

Total dist. in./out. units m 50 50 50 50 50 50

Vertical in./out. unit dist. (1) m 25 25 25 25 25 25

Net weight – outdoor Kg 89 89 109 109 130 135

Net weight – indoor Kg 59 59 61 61 71 71

(1) For distances over 25 m we recommend installing an oil separator Voltage for indoor unit 230.1 50 Hz ~

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

DXCZ/FTZ TECHNICAL SPECIFICATIONS

Page 32: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

31

A03/3

ENERGY SAVING

Head pressure control by frequency converter or voltage converter

AIR QUALITY

Gravimetric filter in return G4

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Indoor unit equipment and accessories painted in RAL 1013 polyester powder coating

Connections on rear, outdoor unit.

Magnetothermics in electrical panel

Power supply at 60Hz and voltages

230, 208, etc. (depending on models)

Option of manufacturing units with symmetric configurationAnti-freeze heater for condenser in tray

Fireproof filter class M0

Thermoacoustic insulation class M0

Hot gas bypass

Discharge plenum and return

Grille discharge plenum and return

3 and 5 outlet nozzle plenum

Condensate evacuation pump

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Anti-corrosion treatment in piping with galval type coating

Prepared for disassemblyOil separator No refrigerant and no flare valves

MAINTENANCE

Service valves External Schrader valves for pressure test

Clogged filter indircation

Split filter

REGULATION AND CONTROL

Pressure switches

Operation for three phase evaporator

ARIA thermostat

PGD thermostat

Infrared remote control

SUPER SI thermostat (man. 24 V)

DSX@ thermostat (man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 33: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

32

A03/4

AXCZ/AXCBZ “Dual” FTZ/FTBZ

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

OUTDOOR MODEL ACXZ 402 ACXZ 442 ACXZ 452 ACXZ 472 ACXZ 502 ACXZ 542

INDOOR MODEL FTZ 201+201 FTZ 221+221 FTZ 201+251 FTZ 221+251 FTZ 251+251 FTZ 271+271

Nominal cooling capacity kW 5.4 + 5.4 6.0 + 6.0 5.4 + 7.4 6.0 + 7.4 7.4 + 7.4 7.9 + 7.9

Nominal cooling capacity R.T. 1.5 + 1.5 1.7 + 1.7 1.5 + 2.1 1.7 + 2.1 2.1 + 2.1 2.2 + 2.2

Total power input kW 4.2 4.4 4.7 4.8 5.14 – 5.06 5.38 – 5.46

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 or 400.3+N 230.1 or 400.3+N

Airflow m3/h -m3/h 1100 – 1100 1100 – 1100 1100 – 1150 1100 – 1150 1150 – 1150 1400 – 1400

static pressure Pa 44 44 44 – 72 44 – 72 72 – 72 96 – 96

Liq. pipe diameter Ø (") 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8

Gas pipe diameter Ø (") 1/2 – 1/2 1/2 – 1/2 1/2 – 5/8 1/2 – 5/8 5/8 – 5/8 3/4 – 3/4

Ext. dimens. (length x width x height) mm 950x407x1349 950x407x1349 950x407x1349 950x407x1349 950x407x1349 950x407x1349

In. dimens. (length x width x height) mmSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

models

Total dist. in./out. units m 50 50 50 50 50 50

Vertical dist. in./out. units m 25 25 25 25 25 25

Net weight – outdoor Kg 131 135 138 139 141 176

Net weight – indoor Kg 37 + 37 37 + 37 37 + 39 37 + 39 39 + 39 43 + 43

AXCZ “Dual”/FTZ TECHNICAL SPECIFICATIONS

AXIAL CONDENSER

DUCTABLE INDOOR UNITS ADVANCE

Maximum flexibility for air conditioning through ducts of commercial premisesAXCZ “Dual”

Cooling only

AXCBZ “Dual”Heat pump

FTZCooling only

FTBZHeat pump

• Cooling capacities ranging from 10.8 to 15.8 kW

• Outdoor units with standard blue fin pre-treated coils

• 3-speed indoor fan

MAIN FEATURESThe units in the AXCZ/FTZ and AXCBZ/FTBZ DUAL series are sets compris-ing a two-circuit axial condenser unit, in general not the same, and two direct expansion fan coil evaporator units. The reduced height of the indoor units make them ideal for fast installation in false ceilings, with the unit either sup-ported or suspended.

• Maximum connection distances between indoor and outdoor units of 50 metres.

• ETN thermostat

Page 34: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

33

A03/4

Voltage for indoor unit 230.1 50 Hz ~

OUTDOOR MODEL ACXBZ 402 ACXBZ 442 ACXBZ 452 ACXBZ 472 ACXBZ 502 ACXBZ 542

INDOOR MODEL FTBZ 201+201 FTBZ 221+221 FTBZ 201+251 FTBZ 221+251 FTBZ 251+251 FTBZ 271+271

Nominal cooling capacity kW 5.2 + 5.2 6.0 + 6.0 5.2 + 7.0 6.0 + 7.0 7.0 + 7.0 7.5 + 7.5

Nominal cooling capacity R.T. 1.5 + 1.5 1.7 + 1.7 1.5 + 2.0 1.7 + 2.0 2.0 + 2.0 2.1 + 2.1

Nominal heating capacity kW 6.2 + 6.2 6.6 + 6.6 6.2 + 8.1 6.6 + 8.1 8.1 + 8.1 8.3 + 8.3

Total power input – cooling kW 4.2 4.4 4.7 4.8 5.14 – 5.06 5.38 – 5.46

Total power input – heating kW 3.6 3.7 4.0 4.0 4.40 – 4.32 4.60 – 4.64

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 – 400.3+N 230.1 – 400.3+N

Airflow m3/h-m3/h 1100 – 1100 1100 – 1100 1100 – 1150 1100 – 1150 1150 – 1150 1400 – 1400

static pressure Pa 44 44 44 – 72 44 – 72 72 – 72 96 – 96

Liq. pipe diameter Ø (") 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8 3/8 – 3/8

Gas pipe diameter Ø (") 1/2 – 1/2 1/2 – 1/2 1/2 – 5/8 1/2 – 5/8 5/8 – 5/8 3/4 – 3/4

Ext. dimens. (length x width x height) mm 950x407x1349 950x407x1349 950x407x1349 950x407x1349 950x407x1349 950x407x1349

Int. dimens. (length x width x height) mmSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

modelsSee FTBZ

models

Total dist. in./out. units m 50 50 50 50 50 50

Vertical dist. in./out. units m 25 25 25 25 25 25

Net weight – outdoor Kg 137 141 143 145 148 182

Net weight – indoor Kg 37 + 37 37 + 37 37 + 39 37 + 39 39 + 39 43 + 43

AXCBZ “Dual”/FTBZ TECHNICAL SPECIFICATIONS

ENERGY SAVING

Compressor soft-start (depending on models)

Head pressure control by frequency converter or voltage converter

AIR QUALITY

Gravimetric filter in return G4

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Indoor unit equipment and accessories painted in RAL 1013 polyester powder coating

Connections on rear, outdoor unit

Magnetothermics in electrical panel

Power supply at 60Hz and voltages

230, 208, etc. (depending on models)Anti-freeze heater for condenser in tray

Fireproof filter class M0

Thermo-acoustic insulation class M0

Hot gas bypass

Hot water heating coil

Electric resistance coils for auxiliary

electric heating

Anti-corrosion pre-treated coils

Anti-corrosion treatment in piping with galval type coating

No refrigerant and no flare valves

Discharge plenum and return

Grille discharge plenum and return

3 and 5 outlet nozzle plenum

Condensate evacuation pump

MAINTENANCE

Service valves External Schrader valves for pressure test

Clogged filter indication

Split filter

REGULATION AND CONTROL

Pressure switches

High pressure switch auto-reset

Operation for three phase evaporator

ETN thermostat

ARIA thermostat

PGD thermostat

Infrared remote control

SUPER SI thermostat (man. 24 V)

DSX@ thermostat (man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch reset from thermostat

Unit without thermostat

Ambient temperature wall sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult

Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 35: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

34

A04/1 HIGH EFFICIENCY. BASIC LINE

RCAH units are static heat recovery units that can be combined with air-cooled or water-cooled air conditioning systems to provide significant energy savings.

• Airflow rates ranging from 500 to 6000 m3/h

• Exchanger of crossed flows in aluminium, with Eurovent certification

• Reduction of consumptions with a minimum thermal

recovery of 50%

• 3 versions available:RCAH Efficiency over 50%RCAH AE Efficiency over 90%RCAH RCF With built-in R410A refrigerated circuit

• Unit available in horizontal or vertical configuration

• Multiple air supply and return options

• Easy accessibility and maintenance of components

• Double panel with insulation structure

• G4 filters included

MAIN FEATURES

HEAT RECOVERY UNITS

Optimisation of the performance ofthe air-conditioningfacilities

RCAH

RCAH TECHNICAL SPECIFICATIONS

MODEL 5 10 20 30 40

Maximum airflow m3/h 500 1000 2000 3200 4300available static pressure Pa 155 125 130 160 180Efficiency % 58.7 56.4 50.0 53.8 54.6Recovered capacity kW 2.4 4.7 8.3 14.3 19.5Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 400.3Maximum input current A 1.4 3.0 7.8 11.4 6.6Sound level at 1 m dB (A) 51.0 52.0 58.0 59.0 62.0Dimensions (length x width x height) mm 750x750x295 900x900x410 1000x1000x470 1300x1300x530 1400x1400x705Weight Kg 41 68 99 155 235

MODEL 50 60

Maximum airflow m3/h 5000 6000available static pressure Pa 99 188Efficiency % 53.8 53.1Recovered capacity kW 22.4 26.5Power supply (50 Hz ~) V 400.3 400.3Maximum input current A 11.2 10.8Sound level at 1 m dB (A) 63.7 64.5Dimensions (length x width x height) mm 1700x1350x705 1900x1450x755Weight Kg 235 273

SE

LF-C

ON

TAIN

ED

AIR

-TO

-AIR

UN

ITS

Performance referring to entry of renewal air at -5ºC (80% RH) and temperature of the extracted air at 20ºC (50% RH)Maximum fan speed

Page 36: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

35

A04/1

ENERGY SAVING

Brushless Fans

Adiabatic cooling kit

AIR QUALITY

Filters F6-F7-F8

Air quality control

UNIT INSTALLATION

By-pass.

Electric heater

Hot water heating coil

(indoor or outdoor)

Cold water cooling coil

3-way valve with actuator

Constant flow rate control

Clogged filter indication

Circular opening

Flexible gasket

Anti-freeze thermostat

Outdoor installation kit

REGULATION AND CONTROL

On/off control and 3-speed switch.

Remote temperature sensor

Basic electronic control

Advanced electronic control

Versions for other climates Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

RCAH AE TECHNICAL SPECIFICATIONS

MODEL 5 10 15 20

Maximum airflow m3/h 500 1000 1500 2000available static pressure Pa 85 130 150 215Efficiency % 90.0 90.1 90.1 90.0Recovered capacity kW 4.1 8.2 12.3 16.3Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1Maximum input current A 3.0 6.2 14.2 11.4Sound level at 1 m dB (A) 52.0 55.0 60.0 59.0Dimensions (length x width x height) mm 1150x860x385 1450x1230x410 1700x1230x490 1700x1230x630Weight Kg 75 120 175 220

RCAH RCF TECHNICAL SPECIFICATIONS

MODEL 10 15 20 25

Maximum airflow m3/h 900 1400 2000 2600discharge static pressure Pa 225 154 187 179return static pressure Pa 184 122 130 148Efficiency (1) % 46.7 44.6 49.2 47.8Total cooling capacity (1) kW 5.4 8.2 12.2 15.0EER (1) W/W 2.8 2.6 2.6 2.9Efficiency (2) % 54.0 51.4 56.9 55.2Total heating capacity (2) kW 8.8 13.7 21.0 26.5COP (2) W/W 6.1 5.6 5.7 5.9Power supply (50 Hz ~) V 230.1 230.1 230.1 400.3Maximum input current A 14.6 21.6 36.3 22.6Sound level at 1 m dB (A) 55.0 52.0 59.0 58.0Dimensions (length x width x height) mm 1450x1230x470 1450x1230x470 1700x1560x530 1700x1560x530Weight Kg 212 225 258 258

MODEL 30 40

Maximum airflow m3/h 3300 4000discharge static pressure Pa 211 159return static pressure Pa 153 133Efficiency (1) % 48.8 47.8Total cooling capacity (1) kW 20.6 23.5EER (1) W/W 2.9 2.8Efficiency (2) % 56.4 55.2Total heating capacity (2) kW 35.1 40.4COP (2) W/W 6.0 5.6Power supply (50 Hz ~) V 400.3 400.3Maximum input current A 26.9 24.8Sound level at 1 m dB (A) 58.0 62.0Dimensions (length x width x height) mm 1900x1700x705 1900x1700x705Weight Kg 305 315

Performance referring to entry of renewal air at -7ºC (80% RH) and temperature of the extracted air at 20ºC (55% RH)Maximum fan speed

(1) Performance referring to entry of renewal air at 32ºC (50% RH) and temperature of the extracted air at 26°C (50% RH)(2) Performance referring to entry of renewal air at -5ºC (80% RH) and temperature of the extracted air at 20°C (50% RH)

SE

LF-CO

NTA

INE

D A

IR-T

O-A

IR U

NIT

S

Page 37: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90
Page 38: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

37

BRoof Top standard version axial fans Page 38

Roof Top standard version axial fans RCF cooling recovery Page 40

Roof Top standard version centrifugal fans Page 42

Roof Top standard version centrifugal fans RCF cooling recovery Page 44

Roof Top standard version MINI centrifugal fans Page 46

ROOF TOP AIR-TO-AIR

Page 39: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

38

B01

MODEL 1402 1602 2002 2402 3002

Nominal cooling capacity kW 40.7 46.2 61.2 71.5 84.5

Nominal cooling capacity R.T. 11.6 13.1 17.4 20.3 24.0

Nominal heating capacity kW 42.2 48.6 63.4 74.6 87.5

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

EER kW/kW 2.7 2.7 2.7 2.8 3.0

COP kW/kW 3.0 3.0 3.0 3.1 3.3

Cooling energy rating (1) 0 C C C C B

Heating energy rating (1) 0 D D D C B

Airflow – static pressure m3/h – Pa 7800-100 9500 – 100 12318 – 135 14075 – 115 14980 – 115

Dimensions (length x width x height) mm 2702x2300x1647 2702x2300x1647 2702x2300x1647 2702x2300x1832 2702x2300x2010

Net weight Kg 1200 1200 1236 1250 1300

RXCA/RXCBA TECHNICAL SPECIFICATIONS

AXIAL FANSRoof top solutions for high flow rates, flexible and adaptable for each project

MAIN FEATURES

• Cooling capacities ranging from 40.7 to 192.3 kW

• Scroll Compressors

• Maximum partialisation up to 9 stages according to models

• Maximum air quality and comfort. Option to install F type high efficiency filters (F6 to F9)

• 3 versions available: standard (STD), with gas burner module (GAS) and the special high ambient temperature version (ATA)

• Thermostats and controls supplied as standard for units with electromagnetic regulation

ARIA – models 1602 to 4502 PGD – models 5002 to 6002

The RXCA-RXCBA series units are self-contained compact rooftop units that are specially designed for installation on rooftops, roof terraces or in any other outdoor location with air distributed treated in ducts.

ROOF TOP UNITS

RXCACooling only

RXCBAHeat pump

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

RO

OF

TO

P A

IR-T

O-A

IR

(1) according to EUROVENT

Page 40: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

39

B01

MODEL 3502 4002 4502 5002 6002

Nominal cooling capacity kW 105.2 115.0 142.6 162.0 192.3

Nominal cooling capacity R.T. 29.9 32.7 40.5 46.1 54.7

Nominal heating capacity kW 109.8 120.0 148.7 167.8 199.4

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

EER kW/kW 2.9 3.1 2.9 3.0 2.9

COP kW/kW 3.6 3.5 3.2 3.3 3.3

Cooling energy rating (1) 0 B A B B B

Heating energy rating (1) 0 A A C B B

Airflow – static pressure m3/h – Pa 17901 – 125 20258-125 25083 – 125 28100 – 150 32800 – 175

Dimensions (length x width x height) mm 4800x2100x1872 4800x2100x1872 4800x2100x1872 4800x2100x2222 4800x2100x2222

Net weight Kg 2200 2210 2240 2600 2710

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start

Soft-start of the indoor and/or outdoor fan

Heat recovery of cooling units(R-404a, etc.)

EC plugfan type indoor fan

EC type axial fans

Head pressure control by voltage converter

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

Outdoor module for F Filterson rail

New airsupply damper

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

Outdoor section fans low sound level

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc.

Option of manufacturing units with symmetric configuration

Upgraded motors

Control of indoor flow when the filters clog up (with EC plugfan type indoor fan)

Anti-freeze heater for condenser in tray

Bottom indoor air discharge

Top indoor air discharge

Rear indoor air discharge (with EC plugfan fans)

Bottom indoor air return

Top indoor air return

Fireproof filter class M0

Thermo-acoustic insulation class M0

Gas burner

Hot gas bypass

Double speed condensation control models 1402/3502

All or nothing condensation control in one fan models 4002/4502

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

Roof curb

Condensation fan with pressure available

RCCBA with centrifuge condensation fan

Condensation tray in outdoor section

Protective grille in outdoor section exchangers

Drip Separator

MAINTENANCE

Service valvesPressure gauges outdoors to read pressuresExternal Schrader valves for pressure test

Clogged filter indication

REGULATION AND CONTROL

PGD thermostat

DSX@ thermostat(requires operation 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch reset from thermostat

Unit without thermostat

Ambient temperature wall sensor

Return temperature sensor (ARIA)

Temperature sensor in duct

Air quality sensor

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Option for customising software with specific functions for the customer

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

RO

OF T

OP

AIR

-TO-A

IR

RXCA/RXCBA TECHNICAL SPECIFICATIONS

Page 41: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

40

B03 AXIAL FANS

HEAT RECOVERYRoof top solution with cooling recovery. Maximum performance in the minimum space

MAIN FEATURES

• Cooling capacities ranging from 53.1 to 233.4 kW • Scroll Compressors• Maximum partialisation up to 9 stages according to

models• Maximum air quality and comfort. Option to install F type

high efficiency filters (F6 to F9)• 3 versions available: with cooling heat recovery (RCF),

with gas burner module (GAS) and special high ambient temperature version (ATA)

• Thermostat – PGD

The RXCA/RXCBA RCF series units are self-contained compact rooftop units that are specially designed for installation on rooftops, roof terraces or in any other outdoor location with air distributed treated in ducts. The heat recovery system uses an additional cooling circuit as a heat exchanger. This purpose of this new circuit is to transfer the energy from the exhaust air to the new ventilation air.

ROOF TOP UNITS

RXCA RCFCooling only

RXCBA RCFHeat pump

MODEL 1402 1602 2002 2402 3002Total cooling capacity kW 53.1 60.6 75.4 92.3 101.9Main circuit cooling capacity kW 40.2 46.6 58.9 71.1 80.2Recovery circuit cooling capacity kW 12.9 14.0 16.5 21.2 21.7Total cooling capacity R.T. 15.1 17.2 21.4 26.2 29.0Main circuit cooling capacity R.T. 11.4 13.2 16.7 20.2 22.8Recovery circuit cooling capacity R.T. 3.7 4.0 4.7 6.0 6.2Total heating capacity kW 55.7 60.1 76.9 93.1 105.5Main circuit heating capacity kW 43.8 47.2 61.7 72.5 85.1Recovery circuit heating capacity kW 11.9 12.9 15.2 20.6 20.4Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+NEER 0 2.9 2.9 2.8 2.9 3.0COP 0 3.4 3.4 3.2 3.2 3.3Cooling energy rating (1) 0 B B C B BHeating energy rating (1) 0 B B C C BAirflow m3/h 7,800 9,500 12,318 14,075 14,980Available discharge pressure Pa 100 100 135 115 115Available return pressure Pa 75 85 85 85 85Dimensions (length x width x height) mm 2702x2300x2175 2702x2300x2175 2702x2300x2175 2702x2300x2360 2702x2300x2540Net weight Kg 1420 1425 1475 1540 1604

RXCA RCF / RXCBA RCF TECHNICAL SPECIFICATIONS

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

RO

OF

TO

P A

IR-T

O-A

IR

Page 42: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

41

B03

MODEL 3502 4002 4502 5002 6002Total cooling capacity kW 125.1 141.4 178.9 202.9 233.4Main circuit cooling capacity kW 100.5 110.4 141.3 160.9 190.9Recovery circuit cooling capacity kW 24.6 31.0 37.6 42.0 42.5Total cooling capacity R.T. 35.6 40.2 50.9 57.7 66.4Main circuit cooling capacity R.T. 28.6 31.4 40.2 45.7 54.3Recovery circuit cooling capacity R.T. 7.0 8.8 10.7 11.9 12.1Total heating capacity kW 130.6 146.9 179.8 202.9 233.9Main circuit heating capacity kW 106.7 116.7 144.5 163.1 193.8Recovery circuit heating capacity kW 23.9 30.2 35.3 39.8 40.1Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+NEER kW 3.3 3.1 3.0 3.1 3.0COP kW 3.7 3.5 3.3 3.4 3.3Cooling energy rating (1) kW A A B A BHeating energy rating (1) kW A A B B BAirflow m3/h 17,901 20,258 25,083 28,100 32,800Available discharge pressure Pa 125 125 125 150 175Available return pressure Pa 70 85 85 85 100Dimensions (length x width x height) mm 4800x2100x2410 4800x2100x2410 4800x2100x2410 4800x2100x2760 4800x2100x2760Net weight Kg 2650 2780 2820 3450 3480

RXCA RCF / RXCBA RCF TECHNICAL SPECIFICATIONS

RO

OF T

OP

AIR

-TO-A

IR

ENERGY SAVING

Thermal or enthalpy regulation for incorporated free cooling with PCO control card and PGD control

Compressor soft-start

Soft-start ofindoor and/or outdoor fan

Head pressure controlby frequency converter

Heat recovery of cooling units (R-404a, etc.)

EC plugfan type indoor fan

EC type axial fans

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

Outdoor module for F Filters on rail

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

Outdoor section fans low sound level

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc.

Option of manufacturing units with symmetric configuration

Upgraded motors

Indoor flow rate control when the filters clog upAnti-freeze heater for condenser in tray

Bottom indoor air discharge

Rear indoor air discharge (with EC plugfan fans)

Top indoor air return

Fireproof filter class M0

Thermo-acoustic insulation class M0

Gas burner

Hot gas bypass

Double speed condensation control models 1402/3502

All or nothing condensation control in one fan models 4002/4502

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

Roof curb

Condensation fan with pressure available

RCCBA with centrifuge condensation fan

Condensation tray in outdoor section

Protective grille in outdoor section exchangers

Drip separator

MAINTENANCE

Service valvesPressure gauges outdoors to read pressuresExternal Schrader valves for pressure test

Clogged filter indication

REGULATION AND CONTROL

PGD thermostat

DSX@ thermostat

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch reset from thermostat

Unit without thermostat

Ambient temperature wall sensor

Return temperature sensor

Temperature sensor in duct

Air quality sensor

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

Page 43: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

42

B04

RO

OF

TO

P A

IR-T

O-A

IR

CENTRIFUGAL FANSShopping centres,multiplex cinemas, large department stores, etc.

MAIN FEATURES

• Cooling capacities ranging from 40.7 to 84.5 kW • Scroll Compressors• Maximum partialisation up to 4 stages according to

models• Maximum air quality and comfort. Option to install F type

high efficiency filters (F6 to F9)• 3 versions available: standard (STD), with gas burner

module (GAS) and the special high ambient temperature version (ATA)

• Standard thermostats and controls for standard units with electromechanical regulation ARIA – models 1402 to 3002

The RCCA/RCCBA series units are self-contained compact roof top units with centrifugal fans on the two sections, suitable for indoor installation. Air distribution is channelled through ducts.

ROOF TOP UNITS

RCCACooling only

RCCBAHeat pump

MODEL 1402 1602 2002 2402 3002

Nominal cooling capacity kW 40.7 46.2 61.2 71.5 84.5

Nominal cooling capacity R.T. 11.6 13.1 17.4 20.3 24.0

Nominal heating capacity kW 42.2 48.6 63.4 74.6 87.5

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

EER kW/kW 2.7 2.6 2.6 2.7 2.8

COP kW/kW 2.9 2.8 2.9 3.0 3.2

Cooling energy rating 0 C D D C C

Heating energy rating 0 D D D D C

Airflow – Static pressure m3/h – Pa 7800-100 9500 – 100 12318 – 135 14075 – 115 14980 – 115

Dimensions (length x width x height) mm 2702x2300x2185 2702x2300x2185 2702x2300x2185 2702x2300x2390 2702x2300x2550

Net weight Kg 1500 1500 1536 1550 1600

RCCA/RCCB TECHNICAL SPECIFICATIONS

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

OUTDOOR SECTION INDOOR SECTION

Page 44: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

43

B04

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start

Soft-start of the indoor and/or outdoor fan

Heat recovery of cooling units (R-404a, etc.)

Head pressure control by frequency converter.

EC plugfan type indoor fan

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

Outdoor module for F Filters on rail

New air supply damper

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc.

Option of manufacturing units with symmetric configuration

Upgraded motors

Indoor flow rate controlwhen the filters clog up

Anti-freeze heater for condenser in tray

Bottom indoor air discharge

Top indoor air discharge

Rear indoor air discharge(with EC plugfan fans)

Bottom indoor air return

Top indoor air return

Fireproof filter class M0

Gas burner (essential PGD thermostat)

Thermo-acoustic insulation class M0

Hot gas bypass

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

Roof curb

Condensation fan with higher pressure available

Protective grille in outdoor section exchangers

Drip separator

MAINTENANCE

Service valvesPressure gauges outdoors to read pressuresExternal Schrader valves for pressure test

Clogged filter indication

REGULATION AND CONTROL

PGD thermostat

DSX@ thermostat (with man. 24 V)

SUPER SI thermostat (with man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch reset from thermostat

Unit without thermostat

Ambient temperature wall sensor

Return temperature sensor

Temperature sensor in duct

Air quality sensor

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

RO

OF T

OP

AIR

-TO-A

IR

Page 45: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

44

B05

RO

OF

TO

P A

IR-T

O-A

IR

CENTRIFUGAL FANSHEAT RECOVERY

MAIN FEATURES

• Cooling capacities ranging from 53.1 to 101.9 kW

• Scroll Compressors

• Maximum partialisation up to 4 stages according to models

• Maximum air quality and comfort. Option to install F type high efficiency filters (F6 to F9)

• 3 versions available: with cooling heat recovery (RCF), with gas burner module (GAS) and special high ambient temperature version (ATA)

• Thermostat – PGD (all models)

The RCCA/RCCBA RCF series units are self-contained compact roof top units with centrifugal fans on the two sections, suitable for indoor installation. Air distribution is channelled through ducts. The heat recovery system uses an additional cooling circuit as a heat exchanger. This purpose of this new circuit is to transfer the energy from the exhaust air to the new ventilation air.

ROOF TOP UNITS

RCCA RCF Cooling only

RCCBA RCF Heat pump

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

Shopping centres,multiplex cinemas, large department stores, etc.

OUTDOOR SECTION INDOOR SECTION

Page 46: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

45

B05

ENERGY SAVING

Thermal or enthalpy regulation for incorporated free cooling with PCO control card and PGD control

Compressor soft-start

Soft-start of the indoor and/or outdoor fan

Heat recovery of cooling units(R-404a, etc.)

Head pressure control by frequency converter.

EC plugfan type indoor fan

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

Outdoor module for F Filters on rail

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc.

Option of manufacturing units with symmetric configuration

Upgraded motors

Indoor flow rate controlwhen the filters clog upAnti-freeze heater for condenser in tray

Bottom indoor air discharge

Rear indoor air discharge(with EC plugfan fans)

Top indoor air return

Fireproof filter class M0

Thermo-acoustic insulation class M0

Gas Burner (essential PGD thermostat)

Hot gas bypass

Hot water heating coils

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

Roof curb

Condensation fan with pressure available

Protective grille in outdoor section exchangers

Drip separator

MAINTENANCE

Service valvesPressure gauges outdoors to read pressuresExternal Schrader valves for pressure test

Clogged filter indication

REGULATION AND CONTROL

PGD thermostat

DSX@ thermostat (with man. 24 V)

SUPER SI thermostat (with man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

Ambient temperature wall sensor

Temperature sensor in duct

Air quality sensor

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

MODEL 1402 1602 2002 2402 3002

Total cooling capacity kW 53.1 60.6 75.4 92.3 101.9

Main circuit cooling capacity kW 40.2 46.6 58.9 71.1 80.2

Recovery circuit cooling capacity kW 12.9 14.0 16.5 21.2 21.7

Total cooling capacity R.T. 15.1 17.2 21.4 26.2 29.0

Main circuit cooling capacity R.T. 11.4 13.2 16.7 20.2 22.8

Recovery circuit cooling capacity R.T. 3.7 4.0 4.7 6.0 6.2

Total heating capacity kW 55.7 60.1 76.9 93.1 105.5

Main circuit heating capacity kW 43.8 47.2 61.7 72.5 85.1

Recovery circuit heating capacity kW 11.9 12.9 15.2 20.6 20.4

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

EER kW/kW 2.9 2.9 2.8 2.9 3.0

COP kW/kW 3.3 3.3 3.1 3.1 3.2

Cooling energy rating 0 B B C B B

Heating energy rating 0 B B C C C

Airflow m3/h 7,800 9,500 12,318 14,075 14,980

Available discharge pressure Pa 100 100 135 115 115

Available return pressure Pa 75 85 85 85 85

Dimensions (length x width x height) mm 2702x2300x2185 2702x2300x2185 2702x2300x2185 2702x2300x2390 2702x2300x2550

Net weight Kg 1720 1725 1775 1840 1904

RCCA/RCCB TECHNICAL SPECIFICATIONS

RO

OF T

OP

AIR

-TO-A

IR

Page 47: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

46

B02 MINI CENTRIFUGAL FANS

RCAZCooling only

RCABZHeat pump

ROOF TOP TYPE UNITS

• Cooling capacities ranging from 29.7 to 70 kW • Thermostats and controls supplied as standard for units

with electromagnetic regulation SUPER SI (man. 24 V)- all models

MAIN FEATURES

The RCAZ/RCABZ series units are self-contained compact roof top units with centrifugal fans on the two sections, suitable for indoor installation. Air distribution is channelled through ducts.For use in shopping centres, multiplex cinemas, large department stores, etc.

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

RCAZ TECHNICAL SPECIFICATIONS

MODEL 1001 1201 1401 1501

Total cooling capacity kW 30.0 35.0 37.2 44.4Total cooling capacity R.T. 8.5 10.0 10.6 12.6Total power input kW 13.6 16.3 16.5 19.3Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NAirflow (in.-out.) m3/h 7000 – 10500 8000 – 12500 8000 – 12500 9000 – 14000indoor static pressure Pa 82 85 85 110outdoor static pressure Pa 65 50 60 80Dimensions (length x width x height) mm 1733x2132x1350 1733x2132x1350 1733x2132x1350 1733x2132x1350Net weight Kg 710 740 765 780

MODEL 2002 2302 2402

Total cooling capacity kW 60.0 67.0 72.0Total cooling capacity R.T. 17.1 19.1 20.5Total power input kW 25.5 27.9 31.3Power supply (50 Hz ~) V 230.3 or 400.3+N 400.3+N 230.3 or 400.3+NAirflow (in.-out.) m3/h 11000 – 18000 12000 – 18500 12000 – 18500indoor static pressure Pa 190 190 190outdoor static pressure Pa 60 78 78Dimensions (length x width x height) mm 2184x2312x1462 2184x2312x1462 2184x2312x1462Net weight Kg 930 939 955

RO

OF

TO

P A

IR-T

O-A

IR

Roof top solutions for high flow rates, flexible and adaptable for each project

Page 48: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

47

B02

RCABZ TECHNICAL SPECIFICATIONS

MODEL 1001 1201 1402 1502

Total cooling capacity kW 29.7 35.0 36.4 44.2Total cooling capacity R.T. 8.4 10.0 10.3 12.6Total heating capacity kW 31.7 37.0 38.6 46.6Total power input – cooling kW 14.1 16.6 16.5 20.0Total power input – heating kW 12.2 14.2 14.3 16.9Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NAirflow (in.-out.) m3/h 7000 – 10500 8000 – 12500 8000 – 13600 10000 – 15600indoor static pressure Pa 82 85 85 125outdoor static pressure Pa 65 50 80 100Dimensions (length x width x height) mm 1733x2132x1350 1733x2132x1350 2075x2262x1350 2075x2262x1350Net weight Kg 715 745 792 807

MODEL 1602 2002 2302 2402

Total cooling capacity kW 45.4 59.4 66.0 70.0Total cooling capacity R.T. 12.9 16.9 18.8 19.9Total heating capacity kW 48.8 63.4 70.0 74.0Total power input – cooling kW 20.2 26.4 28.7 31.1Total power input – heating kW 17.4 22.2 25.0 26.4Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 400.3+N 230.3 or 400.3+NAirflow (in.-out.) m3/h 10000 – 16000 11000 – 22000 12000 – 23000 12000 – 23000indoor static pressure Pa 125 190 190 190outdoor static pressure Pa 90 120 135 135Dimensions (length x width x height) mm 2075x2262x1350 2776x2175x1600 2776x2175x1600 2776x2175x1600Net weight Kg 815 1150 1200 1250

HITECSA recommends the installation of an anti-freeze heater in the water collection tray for ambient temperatures of less than 5°C.

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start

Fan soft-startindoor and/or outdoor fan

Indoor EC radial fan(depending on models)

Head pressure controlby frequency converter

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

Option of fresh air supply damper

Air quality sensor

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Air discharge bottom evaporator

Air discharge top evaporator

Air discharge top condenser

Protection grillein outdoor exchanger

Outdoor installation kit

Upgraded motors

Anti-freeze resistanceoperation in collection tray

Fireproof filter class M0

Thermo-acoustic insulation class M0

Hot gas bypass

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Condenser filter

Split filter

REGULATION AND CONTROLARIA thermostat PGD thermostat DSX@ thermostat (man. 24 V)HoneyWell T8376B thermostat(man. 24 V)Alarm indication

Smoke detectionON/OFF remoteSeparate electrical panelOption of master-slave operation High pressure switch resetfrom thermostatUnit without thermostatWall mounted ambienttemperature sensorReturn temperature sensorTemperature sensor in ductOperation for redundant machineCentralised integrated management operation

Operation without neutralScheduling function and Modbus connection, etc. consultThermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

RO

OF T

OP

AIR

-TO-A

IR

Page 49: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

48

Page 50: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

49

CWATER/AIR compact horizontal exchanger COAXIAL Page 50

WATER/AIR compact horizontal exchanger PLATES Page 52

AIR/AIR compact vertical exchanger COAXIAL Page 54

WATER/WATER compact vertical PLATES exchanger Page 56

SELF-CONTAINED WATER-TO-AIR UNITS

Page 51: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

50

C01 COMPACT HORIZONTAL SELF-CONTAINED UNITS

WCHZCooling only

WCHBZHeat pump

• Cooling capacities ranging from 6.4 to 25.1 kW • Coaxial condenser• Airflows up to 4,600 m3/h• Easy access to inside the unit for maintenance • Reduced dimensions • T-8376B thermostat

MAIN FEATURES

The WCHZ/WCHBZ series are self-contained horizontal units equipped with a water-cooled coaxial condenser, suitable for connection to a network of air distribution ducts.

HITECSA recommends installing units with coaxial condensers given their great robustness for possible impurities in the circuit.

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SELF-CONTAINED WATER-TO-AIR UNITS

Robust and adaptable solutions for facilities by ENERGY LOOP

WCHZ (cooling only) TECHNICAL SPECIFICATIONS

MODEL 201 251 271 351 401

Nominal cooling capacity kW 6.4 8.1 9.0 11.3 13.4

Nominal cooling capacity R.T. 1.8 2.3 2.6 3.2 3.8

Total power input – cooling kW 2.1 2.7 2.7 3.3 4.4

Power supply (50 Hz ~) V 230.1 230.1 230.1 or 400.3+N 230.1- 230.3 o 400.3+N 230.3 or 400.3+N

Airflow – static pressure m3/h – Pa 1500 – 58 1600 – 55 2000 – 77 2300 – 86 2400 – 94

Water connections Ø (") 1/2 1/2 1/2 1/2 3/4

Dimensions (length x width x height) mm 990x520x425 1080x657x484 1200x750x484 1200x750x484 1280x850x542

Net weight Kg 87 104 123 130 147

MODEL 501 701 721 751

Nominal cooling capacity kW 16.6 20.6 22.2 25.1

Nominal cooling capacity R.T. 4.7 5.9 6.3 7.1

Total power input – cooling kW 5.2 6.6 6.2 7.7

Power supply (50 Hz ~) V 230.3 or 400.3+N 400.3+N 230.3 or400.3+N

230.3 or400.3+N

Airflow – static pressure m3/h – Pa 3500 – 70 4300 – 80 4500 – 75 4600 – 120

Water connections Ø (") 3/4 1 1 1

Dimensions (length x width x height) mm 1400x900x542 1600x1030x630 1600x1030x630 1600x1030x630

Net weight Kg 160 240 259 259

SE

LF-C

ON

TAIN

ED

WA

TE

R-T

O-A

IR U

NIT

S

Page 52: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

51

C01WCHBZ (heat pump) TECHNICAL SPECIFICATIONS

MODEL 201 251 351 401 501

Nominal cooling capacity kW 6.0 8.1 11.1 13.0 16.5

Nominal cooling capacity R.T. 1.7 2.3 3.2 3.7 4.7

Nominal heating capacity kW 6.9 9.1 12.6 16.0 19.6

Total power input – cooling kW 1.9 2.6 3.4 4.3 5.1

Total power input – heating kW 1.8 2.5 3.2 4.2 5.0

Power supply (50 Hz ~) V 230.1 230.1 or 400.3+N

230.1-230.3 or 400.3+N

230.3 or 400.3+N 230.3 or 400.3+N

Airflow – static pressure m3/h – Pa 1500 – 58 2000 – 55 2300 – 86 2400 – 94 3500 – 70

Water connections Ø (") 1/2 1/2 1/2 3/4 3/4

Dimensions (length x width x height) mm 1080x675x484 1200x750x484 1200x750x484 1280x850x542 1400x900x542

Net weight Kg 104 130 130 160 185

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers(depending on models)

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start(depending on models)

Fan soft-start(depending on models)

EC radial indoor fan(depending on models)

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Differential pressure switch

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Outdoor installation kit

Upgraded motors

Anti-freeze heater for condenser in tray

Fireproof filter class M0

Hot gas bypass

Pressostatic valve

Inverted intake or discharge

Base guides

Hot water heating coil

Electric resistance coilsfor auxiliary electrical heating

Anti-corrosion pre-treated coils

Seawater condenser

Without water condenser

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Split filter

Pressure gauges

REGULATION AND CONTROL

ETN thermostat

ARIA thermostat

PGD thermostat

DSX@ thermostat

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consultThermostat chapter.

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D W

AT

ER

-TO

-AIR

UN

ITS

Page 53: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

52

C02 COMPACT HORIZONTAL SELF-CONTAINED UNITS

WPHZCooling only

WPHBZHeat pump

• Cooling capacities ranging from 2.7 to 40.5 kW • Plate condenser• Airflow of up to 8,000 m3/h• Easy access to inside the unit for maintenance • Thermostats and controls supplied as standard for units

with electromagnetic regulation: ETN (all models)

MAIN FEATURES

The WPHZ/WPHBZ series are self-contained horizontal units equipped with a water-cooled plate heat exchanger, suitable for connection to a network of air distribution ducts.

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SELF-CONTAINED WATER-TO-AIR UNITS

Robust and adaptable solutions for facilities by ENERGY LOOP

WPHZ/WPHBZ TECHNICAL SPECIFICATIONS

MODEL 091 121 141 171

Nominal cooling capacity kW 2.7 3.5 4.1 5.2Nominal cooling capacity R.T. 0.8 1.0 1.2 1.5Nominal heating capacity kW 3.2 4.1 4.8 6.1Total power input – cooling kW 1.0 1.2 1.3 1.6Total power input – heating kW 1.2 1.5 1.6 1.8Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1Airflow – static pressure m3/h – Pa 500 – 13 550 – 26 900 – 17 1200 – 110Water connections Ø (") 1/2 1/2 1/2 3/4Dimensions (length x width x height) mm 1055x560x385 1055x560x385 1055x560x385 1055x560x470Net weight Kg 79 80 82 85

MODEL 201 251 351 401

Nominal cooling capacity kW 6.4 8.1 11.9 13.4Nominal cooling capacity R.T. 1.8 2.3 3.4 3.8Nominal heating capacity kW 7.6 9.6 14.0 15.8Total power input – cooling kW 1.8 2.4 3.7 4.3Total power input – heating kW 2.0 2.5 3.8 4.4Power supply (50 Hz ~) V 230.1 230.1 230.1-400.3+N 400.3+NAirflow – static pressure m3/h – Pa 1500 – 58 2000 – 55 2300 – 86 2400 – 94Water connections Ø (") 3/4 3/4 3/4 1Dimensions (length x width x height) mm 1055x560x470 1135x670x530 1135x670x530 1135x670x530Net weight Kg 87 104 115 120

SE

LF-C

ON

TAIN

ED

WA

TE

R-T

O-A

IR U

NIT

S

Page 54: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

53

C02

MODEL 501 701 751 1001 1201

Nominal cooling capacity kW 16.6 20.6 25.1 35.4 40.5

Nominal cooling capacity R.T. 4.7 5.9 7.1 10.1 11.5

Nominal heating capacity kW 19.6 24.8 30.1 41.8 49.6

Total power input – cooling kW 4.8 6.4 8.3 11.0 13.4

Total power input – heating kW 5.0 6.6 8.6 11.3 13.8

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Airflow – static pressure m3/h – Pa 3500 – 70 4300 – 80 4800 – 100 5800 – 86 8000 – 85

Water connections Ø (") 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2

Dimensions (length x width x height) mm 1385x940x620 1385x940x620 1385x940x620 1600x1040x690 1600x1040x690

Net weight Kg 160 200 225 275 290

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start(depending on models)

Fan soft-start(depending on models)

EC radial indoor fan(depending on models)

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Option of manufacturing units with symmetric configuration

Rear air discharge

Differential pressure switch

Water shut-off electrovalves

Outdoor installation kit

Upgraded motors

Fireproof filter class M0

Thermo-acoustic insulation class M0

Hot gas bypass

Water regulating pressostatic valve

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

Without water condenser

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Split filter

REGULATION AND CONTROL

ARIA thermostat

PGD thermostat

SUPER SI thermostat (man. 24 V)

HoneyWell T8376B thermostat(man. 24 V)

Eberle thermostat 7007(man. 24 V)

DSX@ thermostat (man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D W

AT

ER

-TO

-AIR

UN

ITS

WPHZ/WPHBZ TECHNICAL SPECIFICATIONS

Page 55: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

54

WCVBZ 201-351 WCVZ 201-751WCVBZ 401

WCVZ 1001-3603

C02 COMPACT VERTICAL SELF-CONTAINED UNITS

WCVZCooling only

WCVBZHeat pump

• Cooling capacities ranging from 6.0 to 120 kW • Coaxial condenser• Airflow rates of up to 21,500 m3/h• Easy access to inside the unit for maintenance • Reduced dimensions • Thermostats and controls supplied as standard for units

with electromagnetic regulation. T8376B (depending on models) SUPER SI (depending on models)

MAIN FEATURES

The WCVZ/WCVBZ series are self-contained vertical units equipped with a water-cooled coaxial condenser, suitable for connection to a network of distribution ducts.

HITECSA recommends installing units with coaxial condensers given their great robustness for possible impurities in the circuit.

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SELF-CONTAINED WATER-TO-AIR UNITS

Robust and adaptable solutions for facilities by ENERGY LOOP

WCVZ (cooling only) TECHNICAL SPECIFICATIONS

MODEL 201 251 271 351 401 501

Nominal cooling capacity kW 6.4 8.1 9.0 11.9 13.4 16.6

Nominal cooling capacity R.T. 1.8 2.3 2.6 3.4 3.8 4.7

Total power input – cooling kW 1.7 2.1 2.3 3.3 3.5 4.5

Power supply (50 Hz ~) V 230.1 230.1 230.1 or400.3+N

230.1-230.3 or400.3+N

230.3 or400.3+N

230.3 or400.3+N

Airflow – static pressure m3/h – Pa 1500 – 58 2000 – 55 2000 – 77 2300 – 86 2400 – 94 3500 – 70

Water connections Ø (") 1/2 1/2 1/2 1/2 1/2 3/4

Dimensions (length x width x height) mm 628x440x1060 720x550x1200 720x550x1200 720x550x1200 780x550x1350 1140x600x1700

Net weight Kg 105 134 134 141 160 245

MODEL 701 721 751 1001 1201 1002

Nominal cooling capacity kW 20.6 23.0 25.1 35.4 40.5 35.6

Nominal cooling capacity R.T. 5.9 6.5 7.1 10.1 11.5 10.1

Total power input – cooling kW 5.4 5.9 6.3 9.8 11.2 9.7

Power supply (50 Hz ~) V 400.3+N 230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

Airflow – static pressure m3/h – Pa 4300 – 80 4500 – 75 4800 – 100 7400 – 70 8200 – 80 7300 – 87

Water connections Ø (") 1 1 1 2 2 2

Dimensions (length x width x height) mm 1140x600x1700 1140x600x1700 1140x600x1700 1700x870x1600 1700x870x1600 1700x870x1600

Net weight Kg 252 252 258 445 472 470

SE

LF-C

ON

TAIN

ED

WA

TE

R-T

O-A

IR U

NIT

S

Page 56: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

55

C02

MODEL 1402 1502 2002 2402 3003 3603

Nominal cooling capacity kW 41.2 50.2 70.8 81.0 105.0 120.0

Nominal cooling capacity R.T. 11.7 14.3 20.1 23.0 29.9 34.1

Total power input – cooling kW 11.3 13.7 19.7 22.4 28.9 33.3

Power supply (50 Hz ~) V 230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

230.3 or 400.3+N

Airflow – static pressure m3/h – Pa 8200 – 80 9000 – 110 11000 – 190 12000 – 190 18000 – 270 21500 – 190

Water connections Ø (") 2 2 2 2 2 2

Dimensions (length x width x height) mm 1700x870x1600 1700x870x1600 1700x980x1950 1700x980x1950 2307x1157x2062 2307x1157x2062

Net weight Kg 515 525 645 706 968 1060

WCVBZ (heat pump) TECHNICAL SPECIFICATIONS

MODEL 201 251 351 401

Nominal cooling capacity kW 6.0 8.1 11.0 13.0

Nominal cooling capacity R.T. 1.7 2.3 3.1 3.7

Nominal heating capacity kW 6.9 9.1 12.6 16.0

Total power input – cooling kW 1.8 2.5 3.3 3.8

Total power input – heating kW 1.8 2.4 3.2 3.8

Power supply (50 Hz ~) V 230.1 230.1 or 400.3+N 230.1-230.3 or 400.3+N 230.3 or 400.3+N

Airflow – static pressure m3/h – Pa 1500 – 58 2000 – 55 2300 – 86 2400 – 94

Water connections Ø (") 1/2 1/2 1/2 1/2

Dimensions (length x width x height) mm 601x625x1000 601x625x1000 601x625x1000 780x550x1350

Net weight Kg 105 134 141 165

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start(depending on models)

Fan soft-start(depending on models)

EC radial indoor fan(depending on models)

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics on electric panel

Power supply at 60Hzand voltages 230, 208, etc.

Outdoor installation kit

Upgraded motors

Anti-freeze heater for condenser tray

Fireproof filter class M0

Hot gas bypass

Water regulating pressostatic

More compact WCVSZ units

WCVCZ units for heating swimming pools

Hot water heating coils (only WCVZ models – cooling only)

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Front discharge (mod. 201/751)

Rear discharge (mod. 1001/3603)

Without water condenser

Seawater condenser

Without compressor

Discharge plenum

Intake grille

Filter in insertable return

Base guides

Pressure gauges

Differential pressure switch

Prepared for disassembly

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Split filter

REGULATION AND CONTROL

ETN thermostat

ARIA thermostat

PGD thermostat

DSX@ thermostat

SUPER SI thermostat

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D W

AT

ER

-TO

-AIR

UN

ITS

WCVZ (cooling only) TECHNICAL SPECIFICATIONS

Page 57: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

56

WPVZ 201-751 WPVZ/BZ 1001-4002

C04 COMPACT VERTICAL SELF-CONTAINED UNITS

WPVZCooling only

WPVBZHeat pump

• Cooling capacities ranging from 8.1 to 132 kW • Plate condenser• Airflow of up to 21,500 m3/h• Easy access to inside the unit for maintenance • Thermostats and controls supplied as standard

for units with electronic regulation ETN- models 251-1501 ARIA- models 2002-4002

MAIN FEATURES

The WPVZ/WPVBZ series are self-contained vertical units equipped with water-cooled plate heat exchangers (one or two depending on the model), suitable for connection to a network of air distribution ducts.

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

SELF-CONTAINED WATER-TO-AIR UNITS

Robust and adaptable solutions for facilities by ENERGY LOOP

WPVZ/WPVBZ TECHNICAL SPECIFICATIONS

MODEL 251 351 401 501

Nominal cooling capacity kW 8.1 11.9 13.4 16.6Nominal cooling capacity R.T. 2.3 3.4 3.8 4.7Nominal heating capacity kW 9.6 14.0 15.8 19.6Total power input – cooling kW 2.4 3.7 4.2 4.8Total power input – heating kW 2.5 3.8 4.4 4.9Power supply (50 Hz ~) V 230.1 230.1 or 400.3+N 400.3+N 400.3+NAirflow – static pressure m3/h – Pa 2000 – 55 2300 – 86 2400 – 94 3500 – 70Water connections Ø (") 3/4 1 1 1 1/4Dimensions (length x width x height) mm 720x650x1230 720x650x1230 780x650x1380 1140x700x1730Net weight Kg 139 146 166 251

MODEL 701 751 1001 1201

Nominal cooling capacity kW 21.0 25.5 35.4 42.0Nominal cooling capacity R.T. 6.0 7.3 10.1 11.9Nominal heating capacity kW 24.8 30.1 41.8 49.6Total power input – cooling kW 6.4 8.3 11.0 13.4Total power input – heating kW 6.6 8.6 11.3 13.8Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+NAirflow – static pressure m3/h – Pa 4300 – 80 4800 – 100 7400 – 70 8200 – 80Water connections Ø (") 1 1/4 1 1/2 1 1/2 1 1/2Dimensions (length x width x height) mm 1140x700x1730 1140x700x1730 1790x870x1630 1790x870x1630Net weight Kg 258 265 450 478

SE

LF-C

ON

TAIN

ED

WA

TE

R-T

O-A

IR U

NIT

S

Page 58: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

57

C04

MODEL 1501 2002 2402 3002 4002

Nominal cooling capacity kW 54.0 70.8 84.0 108.0 132.0

Nominal cooling capacity R.T. 15.4 20.1 23.9 30.7 37.5

Nominal heating capacity kW 63.7 83.5 99.1 127.4 155.8

Total power input – cooling kW 15.9 22.6 26.5 35.0 43.0

Total power input – heating kW 16.4 23.3 27.3 36.0 44.3

Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N

Airflow – static pressure m3/h – Pa 9000 – 110 11000 – 190 12000 – 190 18000 – 270 21500 – 190

Water connections Ø (") 1 1/2 1 1/2 1 1/2 2 2

Dimensions (length x width x height) mm 1790x870x1630 1790x980x1980 1790x980x1980 2404x1157x2092 2404x1157x2092

Net weight Kg 515 650 711 973 1065

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

Thermal or enthalpy regulation with PCO control card and PGD control

Compressor soft-start(depending on models)

Fan soft-start(depending on models)

EC radial fan(depending on models)

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Option of manufacturing units with symmetric configuration

Outdoor installation kit

Upgraded motors

Fireproof filter class M0

Thermo-acoustic insulation class M0

Filter in insertable return

Differential pressure switch

Intake grille

Without water condenser

Water regulating pressostatic valve

Rear discharge (mod. 1001-4002)

Front discharge (mod. 201-751)

Discharge plenum

Hot gas bypass

Hot water heating coil

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Clogged filter indication

Split filter

REGULATION AND CONTROL

ARIA thermostat

PGD thermostat

SUPER SI thermostat (man. 24 V)

HoneyWell T8376B thermostat(man. 24 V)

Eberle thermostat 7007(man. 24 V)

DSX@ thermostat (man. 24 V)

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

High pressure switch resetfrom thermostat

Unit without thermostat

Wall mounted ambienttemperature sensor

Return temperature sensor

Temperature sensor in duct

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consultThermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

SE

LF-CO

NTA

INE

D W

AT

ER

-TO

-AIR

UN

ITS

WPVZ/WPVBZ TECHNICAL SPECIFICATIONS

Page 59: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

58

Page 60: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

59

DMINI ADVANCE i, AIR/WATER units axial fans Page 62

MINI KRONO X, AIR/WATER units axial fans Page 63

KRONO X, AIR/WATER units axial fans medium power Page 65

ADVANCE X, AIR/WATER units axial fans high power, scroll Page 68

ADVANCE XT, AIR/WATER units axial fans high power, screw Page 70

KRONO C, AIR/WATER units centrifugal fans medium power Page 72

ADVANCE W, WATER/WATER units scroll compressors Page 74

ADVANCE WT, WATER/WATER screw compressors Page 77

WATER CHILLER UNITS

Page 61: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

60

D01

WA

TE

R C

HIL

LER

UN

ITS

kW

axia

lfa

nsce

ntrif

ugal

fans

KRONO CZ AND CBZ (16 to 78 kW) scroll R407c

140 kW20 kW

MINIADVANCE i(20 to 30 kW)

KRONO XA AND XBA(40 to 136 kW) scroll R410a

MINIKRONO XZ AND XBZ(20 to 35 kW) scroll R407c

Air-Water Range

WATER CHILLER UNITS

40 kW

kW

ADVANCE W (20 to 380 kW) scroll R410a

270 kW

Water-Water Range

WATER CHILLER UNITS

380 kW

Page 62: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

61

D01

WA

TE

R C

HILLE

R U

NITS

1650 kW634 kW290 kW

ADVANCE XA and XBA (150 to 634 kW) scroll R410a

ADVANCE XAT (290 to 1650 kW) screw R134

ADVANCE WT (270 to 1120 kW) screw R134

1120 kW

Page 63: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

62

D01 AXIAL FANS

MINI ADVANCE iHeat pumpINVERTER

Inverter solution for small power applications. Ideal for underfloor heating

• Cooling capacities ranging from 20 to 30 kW

• Compressors scroll inverter BLDC

• R410A refrigerant

• Energy rating A

• Variable capacity: from 30% of the nominal capacity

• High performance at partial loads

• High precision in the maintenance of the required water temperature

• Optimised unit in heating mode for both fan coil and for underfloor heating

• Includes standard condensation control and water pump

• Electronic expansion valve

• Includes standard water filter

• Ample operating limits in heating mode: Minimum outdoor air temperature -15°C – Maximum water outlet temperature +55ºC

• Modbus communication

• Coil with standard blue prelacquered fin

MAIN FEATURES

The EWFAIB air-water heat pumps are units equipped with an inverter compressor for R410A and water pump.Thanks to its new microprocessor and regulation logic it can operate with a low water flow.

MODEL 20.1 25.1 30.1

Cooling capacity (min/nom/max) (1) kW 7.1 20.2 25.6 8.9 25.0 30.4 10.1 29.3 31.8

Cooling capacity (min/nom/max) (1) R.T. 2.0 5.7 7.3 2.5 7.1 8.6 2.9 8.3 9.0

Power input (1) kW 2.0 6.0 8.5 2.2 7.5 10.2 2.5 9.4 10.6

EER 0 3.56 3.36 3.03 4.11 3.36 2.98 4.09 3.11 3.0

Heating capacity (min/nom/max) (1) kW 6.1 18.1 22.9 8.5 21.7 28.6 9.2 25.1 29.9

Power input (1) kW 2.4 6.2 8.2 3.0 7.1 10.3 3.2 8.5 10.7

COP kW/ kW 2.54 2.91 2.80 2.83 3.04 2.78 2.85 2.95 2.8

EWFAIB TECHNICAL SPECIFICATIONS

ESSER kW/ kW 4.50 4.83 4.63

Power supply (50 Hz ~) V 400.3 + N 400.3 + N 400.3 + N

Water connection (inlet/outlet) Ø (") 1 1/2 1 1/2 1 1/2

Dimensions (length x width x height) mm 1477x538x1625 1477x538x1625 1477x538x1625

Weight Kg 269 285 285

(1) Conditions in heating mode: water inlet 40ºC / water outlet 45ºC, ambient air temperature 7ºC Conditions in cooling mode: water inlet 12ºC / water outlet 7ºC, ambient air temperature 35ºC

UNIT INSTALLATION

Kit without water pump

Tank kit for 112 litres

inlet/outlet valve kit

MAINTENANCE

Pressure gauge kit

REGULATION AND CONTROL

Flow switch

ON/OFF remote control

Sequencer for installationsup to 4 units

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

WATER CHILLER UNITS

WA

TE

R C

HIL

LER

UN

ITS

Page 64: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

63

D01AXIAL FANS

MINI KRONO XZCooling only

MINI KRONO XBZHeat pump

WATER CHILLER UNITS

• Cooling capacities ranging from 20.2 to 234.2 kW • Independent cooling circuits • Scroll Compressors • Thermostats and controls supplied as standard for units

with electromagnetic regulation. Microchiller2- models 801-4502 DN 33- models 6004-9004

MAIN FEATURES

The EWXZ/EWXBZ chiller units are compact units designed for outdoor installation on flat roofs, terraces or on the ground.For application in health centres, hotels, offices, industrial process units, hospitals, etc.

EWXZ TECHNICAL SPECIFICATIONS

MODEL 801 1001 1201 1501 1602

Nominal cooling capacity kW 20.5 25.5 30.5 35.5 41.5Nominal cooling capacity R.T. 5.8 7.3 8.7 10.1 11.8Power input – cooling kW 8.2 10.6 14.2 15.5 16.3Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 1 1/2 1 1/2 1 1/2 2 2Water flow l/s 1.0 1.2 1.5 1.7 2.0Water load loss kPa 36 37 36 37 38Dimensions (length x width x height) mm 1520x1019x1455 1520x1019x1455 1520x1019x1455 1520x1019x1805 1864x1307x1455Net weight Kg 257 267 274 328 545

MODEL 2002 2402 3002 3502 4002

Nominal cooling capacity kW 51.0 61.0 71.5 83.3 99.5Nominal cooling capacity R.T. 14.5 17.3 20.3 23.7 28.3Power input – cooling kW 21.2 28.4 31.0 34.7 40.9Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 2 2 2 2 2Water flow l/s 2.4 2.9 3.4 4.0 4.8Water load loss kPa 41 39 40 38 37Dimensions (length x width x height) mm 1864x1307x1455 2174x1407x1505 2174x1407x1805 2450x2031x1755 2450x2031x1755Net weight Kg 575 650 840 895 1100

MODEL 4502 6004 7004 8004 9004

Nominal cooling capacity kW 118.0 143.1 166.6 198.9 236.2Nominal cooling capacity R.T. 33.6 40.7 47.4 56.6 67.2Power input – cooling kW 50.3 62.0 69.4 81.8 100.6Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 2 3 4 4 4Water flow l/s 5.6 6.8 8.0 9.5 11.3Water load loss kPa 38 57 56 55 58Dimensions (length x width x height) mm 2450x2031x1805 2250x2177x1826 3744x2250x1826 3744x2250x1826 3744x2250x1826Net weight Kg 1250 1560 1920 2400 2700

Robustness and simplicity at the service of air-conditioning

WA

TE

R C

HILLE

R U

NITS

Page 65: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

64

D02

EWXBZ TECHNICAL SPECIFICATIONS

MODEL 801 1001 1201 1501 1602Nominal cooling capacity kW 20.2 25.0 29.8 34.6 40.4Nominal cooling capacity R.T. 5.7 7.1 8.5 9.8 11.5Nominal heating capacity kW 22.0 27.0 32.0 37.0 43.0Power input – cooling kW 8.2 10.6 14.2 15.5 16.3Heating power input kW 8.0 10.2 12.9 15.0 16.0Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 1 1/2 1 1/2 1 1/2 2 2Water flow l/s 1.0 1.2 1.4 1.7 1.9Water load loss kPa 36 36 35 36 36Dimensions (length x width x height) mm 1520x1019x1455 1520x1019x1455 1520x1019x1455 1520x1019x1805 1864x1307x1455Net weight Kg 240 340 360 385 545

MODEL 2002 2402 3002 3502 4002Nominal cooling capacity kW 50.0 59.8 70.9 82.5 98.5Nominal cooling capacity R.T. 14.2 17.0 20.2 23.5 28.0Nominal heating capacity kW 53.0 63.0 84.3 96.0 114.7Power input – cooling kW 21.2 28.4 31.0 34.7 40.9Heating power input kW 20.3 26.0 30.1 34.0 40.0Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 2 2 2 2 2Water flow l/s 2.4 2.9 3.4 3.9 4.7Water load loss kPa 39 38 40 38 37Dimensions (length x width x height) mm 1864x1307x1455 2174x1407x1505 2174x1407x1805 2450x2031x1755 2450x2031x1755Net weight Kg 575 650 840 860 1200

MODEL 4502 6004 7004 8004 9004Nominal cooling capacity kW 117.1 141.8 165.0 197.0 234.2Nominal cooling capacity R.T. 33.3 40.3 46.9 56.0 66.6Nominal heating capacity kW 138.2 168.6 192.0 229.4 276.4Power input – cooling kW 50.3 62.0 69.4 81.8 100.6Heating power input kW 49.4 60.2 64.0 80.0 98.8Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 2 3 4 4 4Water flow l/s 5.6 6.8 7.9 9.4 11.2Water load loss kPa 38 57 55 54 57Dimensions (length x width x height) mm 2450x2031x1805 2250x2177x1826 3744x2250x1826 3744x2250x1826 3744x2250x1826Net weight Kg 1350 1600 1720 2400 2700

ENERGY SAVINGCompressor soft-startHead pressure controlby frequency converter

SOUND LEVELCompressor sound jacketLow sound level outdoor fan

UNIT INSTALLATIONMagnetothermics in electrical panelPower supply at 60Hzand voltages 230, 208, etc.Upgraded motorsAnti-freeze resistanceoperation in collection tray

Outdoor reading pressure gaugesMulti-tube evaporatoroption on requestOutdoor inertia module, MWIBuilt-in hydronic kit. Built-in hydronic kitwith double pumpAnti-corrosion pre-treated coilsDischarge temperature under 7ºCDifferential pressure switchPrepared for disassembly

MAINTENANCEService valvesExternal Schrader valves for pressure test

REGULATION AND CONTROLPrepared for HydrofanMicrochiller remote controlAlarm indicationON/OFF remoteSeparate electrical panelOption of master-slave operation Operation for redundant machineCentralised integrated management operation

Operation without neutralScheduling function and Modbus connection, etc. consultThermostat chapter

Versions for other climates Versions for other power supplies

OPTIONS AVAILABLE

As well as these options, consult our Commercial Departmentfor any other configuration not described as available.

0 701 801 1001 1201 1501

EWCZ/EWCBZ · · · ·

EWXZ/EWXBZ · · · · ·

EWWZ · · · ·

EWSZ · · · ·

MODEL 150

Total power input kW 0.8

Total input current A 1.3

Power supply (50 Hz ~) V 400.3+N

Water tank L 150

Expansion vessel L 18

Dimensions mm 1070x753x1267

Net weight Kg 170

MODEL 150

MWI Inertia module

WA

TE

R C

HIL

LER

UN

ITS

Page 66: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

65

D02AXIAL FANS

Built-in units for air-conditioning solutions. Flexibility and reliability combined

MAIN FEATURES

• Cooling capacities ranging from 45.3 to 136.0 kW

• A refrigerated circuit with scroll compressors in tandem

• High energy efficiency

• Standard supplied MCX control

• Head pressure control in cooling and evaporation in pump by stages

• Differential pressure switch

• ON/OFF remote

• Remote winter/summer

• Scheduling function

The EWXA/EWXBA chiller units are compact units designed for outdoor installation on flat roofs, terraces or on the ground.

WATER CHILLER UNITS

KRONO XACooling only

KRONO XBAHeat pump

EWXA/EWXBA TECHNICAL SPECIFICATIONS

MODEL 1601.2 2001.2 2401.2 2501.2 3001.2

Nominal cooling capacity kW 45.3 52.6 61.5 67.8 77.3Nominal cooling capacity R.T. 12.9 14.9 17.5 19.3 22.0Nominal heating capacity kW 53.1 62.0 73.8 79.3 84.9

EER kW/kW 2.8 2.8 2.8 2.8 3.0

COP kW/kW 3.3 3.3 3.4 3.2 3.1Power supply (50 Hz ~) (1) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+NWater connections Ø (") 2 2 2 2 2Water flow m3/h 7.8 9.0 10.6 11.7 13.3Water load loss kPa 22 24 26 26 32Dimensions (length x width x height) mm 2450x1220x1640 2450x1220x1640 2450x1220x1640 2860x1220x1630 2860x1220x1630Net weight Kg 730 740 770 870 880

MODEL 3201.2 3501.2 4001.2 4501.2 5001.2

Nominal cooling capacity kW 81.3 94.9 112.5 125.1 136.0Nominal cooling capacity R.T. 23.1 27.0 32.0 35.6 38.7Nominal heating capacity kW 88.6 103.4 123.0 136.0 146.3

EER kW/kW 2.8 2.8 2.8 2.9 3.0

COP kW/kW 2.9 3.0 3.2 3.2 3.3Power supply (50 Hz ~) V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+NWater connections Ø (") 2 2 2 2 2Water flow m3/h 14.0 16.3 19.4 21.5 23.4Water load loss kPa 30 35 41 43 46Dimensions (length x width x height) mm 2860x1220x1630 3400x1220x1640 3400x1220x1640 3400x1220x1640 3400x1220x1640Net weight Kg 900 1040 1120 1200 1250

Data referring to operating conditions according to EUROVENT(1) Other voltages and frequencies available for power supply

WA

TE

R C

HILLE

R U

NITS

Page 67: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

66

D03

1 2 3 T.ININ

T.OUT

OUT

1 2 3 4

5

6 T.ININLET

T.OUT

OUTLET

ENERGY SAVING

Compressor soft-start

Partial heat recoverer (DHW)

EC fans

Head pressure control by frequency converter or voltage converter

SOUND LEVEL

Compressor sound jacket

Silent

Super-silent

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc.

Upgraded fans

Upgraded pumps

Built-in inertia module (with tank, etc.)

Built-in hydronic kit.(without tank)

Built-in pump

Double or twin pumpAnti-freeze heater for condenser in tray

Anti-corrosion pre-treated coils

Prepared for disassembly

Multi-tube evaporator option – on request (only without hydronic kit)

Protective grille in outdoor exchangers

Victaulic outdoor connections

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Refrigerant pressure gauges

Water pressure gauges

Water filter

REGULATION AND CONTROL

Second setpoint

Alarm indication

Separate electrical panel

Option of master-slave operation

Operation without neutral

Modbus connection, etc. consult Thermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

HYDRAULIC DIAGRAMS EWXA/EWXBA. Standard diagram

HYDRAULIC DIAGRAMS EWXA/EWXBA. 1 pump hydronic kit (without tank)

COMPONENTS

1. Plate heat exchanger2. Purge valve3. Water filter (optional)

COMPONENTS

1. Plate heat exchanger2. Purge valve3. Water pump4. Shut-off valve5. Expansion vessel6. Water filter (optional)

WA

TE

R C

HIL

LER

UN

ITS

Page 68: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

67

D03

6

1 2 3 4 5

7INLET

T.IN

T.OUT

OUTLET

12

2

3 8

3

49

11

10

4

5

7

6

T.ININLET

T.OUT

OUTLET

1 2 38

9

10

7

6

T.ININLET

T.OUT

OUTLET

HYDRAULIC DIAGRAMS EWXA/EWXBA. 2 pump hydronic kit (without tank)

COMPONENTS

1. Plate heat exchanger2. Purge valve3. Check valve4. Water pump5. Shut-off valve6. Expansion vessel7. Water filter (optional)

HYDRAULIC DIAGRAMS EWXA/EWXBA. Inertial module 1 pump (with tank)

COMPONENTS

1. Plate heat exchanger2. Check valve3. Water pump4. Shut-off valve5. Purge valve6. Water tank7. Expansion vessel8. Safety valve9. Pressure gauge10. Emptying valve11. Water filter (optional)

HYDRAULIC DIAGRAMS EWXA/EWXBA. Inertial module 1 pump (with tank)

COMPONENTS

1. Plate heat exchanger2. Water pump3. Shut-off valve4. Purge valve5. Water tank6. Expansion vessel7. Safety valve8. Pressure gauge9. Emptying valve10. Water filter (optional)

WA

TE

R C

HILLE

R U

NITS

Page 69: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

68

EWFV/EWFVB 360.4-600.4EWFV/EWFVB 140.4-300.4

D04 AXIAL FANS

Solutions in water for medium power. CLIMATE and INDUSTRY applications

EWFV cooling only / EWFVB heat pump TECHNICAL SPECIFICATIONS

MODEL 150.4 170.4 200.4

Nominal cooling capacity (1) kW 150.1 174.0 197.6Nominal cooling capacity (1) R.T. 42.7 49.5 56.2

Power input kW 50.2 59.4 65.5

EER kW/kW 2.69 2.67 2.78ESEER kW/kW 3.63 3.62 3.75Nominal heating capacity (1) kW 169.0 199.2 234.9Power input kW 51.3 60.6 69.8COP kW/kW 3.3 3.3 3.4Power supply (50 Hz ~) (2) V 400.3 400.3 400.3Water flow l/s 7.2 8.3 9.4Water load loss kPa 36.1 47.5 49.1Water connection (inlet/outlet) Ø (") 2 1/2 2 1/2 2 1/2Dimensions (length x width x height) mm 3300x1100x2300 4300x1100x2300 4300x1100x2300Net weight Kg 1473 1663 1806

ADVANCE XACooling only

ADVANCE XBAHeat pump

• Cooling capacities ranging from 130 to 600 kW

• R410A refrigerant

• 2 separate circuits with scroll compressors in tandem or trio by circuit

• Standard encapsulated compressors

• 4 versions available Super-silent (SS) High Seasonal Energy Efficiency (AEE) High Ambient Temperatures (ATA) High Pressure Fans (APV)

• Energy class C

MAIN FEATURESThe EWFV/EWFVB chiller units are high performance units offering multiple configuration options. • Standard electronic valv

• Standard differential pressure switch

• Single or double pump with 2 versions: standard or high pressure

• Partial or total recoverer

• Condensation control by steps in standard version or proportional in other versions

• Optimised design that allows the incorporation of options in units already installed

WATER CHILLER UNITS

(1) Data of the reversible version (heat pump) (2) Without neutral

WA

TE

R C

HIL

LER

UN

ITS

Page 70: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

69

D04

ENERGY SAVINGLow condensation control for temperatures Total heat recovery (only cooling model) or partial recovery (20%)Compressor soft-startPower factor correctionInverter fans in versions AEE and APV

SOUND LEVELStandard silent versionoptional super-silent versionAcoustic insulation water pump

UNIT INSTALLATIONBuilt-in hydronic kitwith 1 or 2 pumps

Built-in inertia tankAnti-freeze electric coils inside the inertia tankInlet/outlet valve kitDouble setpointWater filterPre-treated coils for corrosive environmentsCoil protection grilleLow temperature kit (-18ºC)Anti-vibration support for assembly of the unitMulti-tube exchanger

MAINTENANCEHigh and low pressure gauges

REGULATION AND CONTROLIntegration with BMS applications (Modbus, BacNet, EtherNet)Flow switchRemote control panelRemote control keypadMaster-slave control(up to 4 units)

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

EWFV cooling only / EWFVB heat pump TECHNICAL SPECIFICATIONSMODEL 360.4 400.4 470.6 540.6 600.6

Nominal cooling capacity (1) kW 360.2 401.7 472.2 537.0 601.9Nominal cooling capacity (1) R.T. 102.4 114.2 134.3 152.7 171.1Power input kW 119.0 134.0 156.0 178.5 201.0EER kW/kW 3.03 3.00 3.03 3.01 2.99ESEER kW/kW 3.90 3.80 3.89 3.80 3.80

Nominal heating capacity (1) kW 418.1 467.6 545.7 623.9 702.0Power input kW/kW 116.0 130.0 151.8 173.4 195.0COP kW/kW 3.6 3.6 3.6 3.6 3.6Power supply (50 Hz ~) (2) V 400.3 400.3 400.3 400.3 400.3Water flow l/s 18.2 20.2 23.7 26.9 30.3Water load loss kPa 50.4 50.3 55 70.6 76.4Water connection (inlet/outlet) Ø (") 4 4 4 4 4Dimensions (length x width x height) mm 4000x2200x2550 4000x2200x2550 5000x2200x2550 6000x2200x2550 6000x2200x2550Net weight Kg 2732 3018 3723 4083 4169

EWFV cooling only / EWFVB heat pump TECHNICAL SPECIFICATIONS

MODEL 230.4 250.4 270.4 300.4

Nominal cooling capacity (1) kW 226.7 246.8 273.9 300.5Nominal cooling capacity (1) R.T. 64.5 70.2 77.9 85.4

Power input kW 74.2 78.4 91.3 105.7

EER kW/kW 2.77 2.87 2.77 2.65ESEER kW/kW 3.75 3.88 3.75 3.59Nominal heating capacity (1) kW 254.1 272.5 300.8 335.8Power input kW 71.4 79.3 91.3 103.4COP kW/kW 3.6 3.4 3.3 3.3Power supply (50 Hz ~) (2) V 400.3 400.3 400.3 400.3Water flow l/s 10.8 11.8 13.1 14.4Water load loss kPa 22.6 26.8 33.0 39.7Water connection (inlet/outlet) Ø (") 3 3 3 3Dimensions (length x width x height) mm 4300x1100x2300 4300x1100x2300 4300x1100x2300 4300x1100x2300Net weight Kg 1955 2100 2190 2200

Complete hydraulic circuit with hydronic kit with double pump and inertia tank. For simpler versions, consult the commercial department.

HYDRAULIC DIAGRAM EWFV/EWFVB

COMPONENTS1. Plate heat exchanger2. Pump3. Drainage valve4. Inertia tank5. Water filter6. Check valve7. Expansion vessel8. Drainage/pressure connection9. Water outlet10. Water inlet11. Damper valve12. Flexible connection13. Bypass valve

REGULATION AND CONTROLA. Water inlet temperature sensorB. Water outlet temperature sensorC. Water differential pressure switchD. Air purgerE. Safety valveFS. Flow switch.... Inside the unitO. Sensors

WA

TE

R C

HILLE

R U

NITS

Page 71: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

70

D05 AXIAL FANS

Chiller units with screw compressor. Maximum adaptability to the demand

ADVANCE XATCooling only

EWFD cooling only TECHNICAL SPECIFICATIONS

MODEL 300.2 330.2 370.2 410.2 410.2Nominal cooling capacity (1) kW 293.0 326.2 365.6 410.6 455.5

Nominal cooling capacity (1) R.T. 83.3 92.7 104.0 116.7 129.5

Power input (2) kW 95.8 111.8 126.2 150.4 159.6

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3

EER kW/kW 3.10 2.90 2.90 2.70 2.90Sound level at 10 m dB (A) 64 64 65 66 66Water connection (IN/OUT) Diam. (") 5 5 5 5 6Dimensions (length x width x height) mm 4000x2200x2550 4000x2200x2550 4000x2200x2550 4000x2200x2550 4000x2200x2550Net weight Kg 3529 3547 3629 4068 4587

MODEL 480.2 510.2 550.2 620.2 660.2Nominal cooling capacity (1) kW 480.5 513.6 546.8 620.3 660.0

Nominal cooling capacity (1) R.T. 136.6 146.0 155.5 176.4 187.7

Power input (2) kW 175.6 189.6 203.6 207.4 215.1

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3

EER kW/kW 2.70 2.70 2.70 3.00 3.10Sound level at 10 m dB (A) 66 66 66 68 68Water connection (IN/OUT) Diam. (") 6 6 6 6 8Dimensions (length x width x height) mm 4000x2200x2550 4000x2200x2550 4000x2200x2550 6000x2200x2550 6000x2200x2550Net weight Kg 4587 4609 4627 6229 6607

(1) Data calculated at outlet water temperature 7ºC and ambient air temperature 35ºC(2) Only compressor consumption

MAIN FEATURES

• Cooling capacities ranging from 300 to 550 kW

• R134A refrigerant

• 2 independent circuits with 1 screw compressor per circuit

• 4 versions availableSilent (SI)Super-silent (SS)High Efficiency (AE) High Pressure Fan (APV)

• Standard encapsulated compressors

• Multi-tube evaporator

• Double setpoint

• Screw compressor, maximum partialisation

The EWFD chiller units are high performance units offering multiple configuration options.

WATER CHILLER UNITS

WA

TE

R C

HIL

LER

UN

ITS

Page 72: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

71

D05

ENERGY SAVINGLow condensation control for temperatures Total heat recoveryCompressor soft-startPower factor correctionInverter fans in versions AE and APV

SOUND LEVELStandard silent versionoptional super-silent version

UNIT INSTALLATIONBuilt-in or remote hydronic kitHydronic kit with or without inertia tank

Single or double pump, lowor high pressure Coil and machine protective grillesWater filterCoils with pre-treatment for corrosive environments (black epoxy, copper-copper, etc.)Anti-vibration support for assembly of the unitPhase fault controlElectronic expansion valveFlow switchCompressor intake valvesCompressor liquid injection valves

MAINTENANCEHigh and low pressure gauges

REGULATION AND CONTROLIntegration with BMS applications (Modbus, BacNet, EtherNet)Remote control panelRemote control keypadMaster-slave control (up to 4 units)

Versions for other climates Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

MODEL 720.2 760.2 820.2 910.2 960.2Nominal cooling capacity (1) kW 718.6 758.8 823.3 908.8 962.4

Nominal cooling capacity (1) R.T. 204.3 215.8 234.1 258.4 273.6

Power input (2) kW 234.6 254.1 289.5 292.7 312.9

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3

EER kW/kW 3.10 3.00 2.80 3.10 3.10Sound level at 10 m dB (A) 68 68 68 68 68Water connection (IN/OUT) Diam. (") 8 8 8 8 8Dimensions (length x width x height) mm 6000x2200x2550 6000x2200x2550 6000x2200x2550 8000x2200x2550 8000x2200x2550Net weight Kg 6767 6920 7036 8349 8791

MODEL 1030.2 1100.2 1170.2 1240.2 1320.2Nominal cooling capacity (1) kW 1027.2 1093.6 1167.1 1240.6 1320.0

Nominal cooling capacity (1) R.T. 292.1 310.9 331.8 352.7 375.3

Power input (2) kW 355.8 382.2 385.3 388.4 430.2

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3

EER kW/kW 2.90 2.90 3.00 3.20 3.10Sound level at 10 m dB (A) 69 69 69 70 70Water connection (IN/OUT) Diam. (") 6 6 6 6 8Dimensions (length x width x height) mm 8000x2200x2550 8000x2200x2550 10000x2200x2550 12000x2200x2550 12000x2200x2550Net weight Kg 9218 9254 10856 12449 13205

MODEL 1440.2 1520.2 1650.2Nominal cooling capacity (1) kW 1437.2 1517.6 1646.6

Nominal cooling capacity (1) R.T. 408.6 431.5 468.2

Power input (2) kW 469.2 508.2 579.0

Power supply (50 Hz~) V 400.3 400.3 400.3

EER kW/kW 3.10 3.00 2.80Sound level at 10 m dB (A) 70 70 70Water connection (IN/OUT) Diam. (") 8 8 8Dimensions (length x width x height) mm 12000x2200x2550 12000x2200x2550 12000x2200x2550Net weight Kg 13534 13831 14072

EWFD cooling only TECHNICAL SPECIFICATIONS

Complete hydraulic circuit with hydronic kit with double pump and inertia tank. For simpler versions, consult the commercial department.

HYDRAULIC DIAGRAM EWFD

COMPONENTS1. Plate heat exchanger2. Pump3. Drainage valve4. Inertia tank5. Water filter6. Check valve7. Expansion vessel8. Drainage/pressure connection9. Water outlet10. Water inlet11. Damper valve12. Flexible connection13. Bypass valve

REGULATION AND CONTROLA. Water inlet temperature sensorB. Water inlet temperature sensorC. Water differential pressure switchD. Air purgerE. Safety valveFS. Flow switch.... Inside the unitO. Sensors

WA

TE

R C

HILLE

R U

NITS

Page 73: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

72

D06

701, 3002 3502

CENTRIFUGAL FANS

KRONO CZCooling only

KRONO CBZHeat pump

WATER CHILLER UNITS

Chillers units with centrifugal fan: solutions for space problems

• Cooling capacities ranging from 15.9 to 78.5 kW • Independent cooling circuits • Scroll Compressors• Thermostats and controls supplied as standard

for electromechanical regulation units Microchiller2 (all models)

MAIN FEATURES

The EWCZ/EWCBZ chiller units are compact air-to-water units especially designed for indoor installation.For application in health centres, hotels, offices, industrial process units, hospitals, etc.

EWCZ TECHNICAL SPECIFICATIONS

MODEL 701 801 1001 1201 1602

Nominal cooling capacity kW 16.2 19.8 24.5 30.3 39.6Nominal cooling capacity R.T. 4.6 5.6 7.0 8.6 11.3Power input – cooling kW 5.4 6.3 8.2 9.5 13.0Power supply (50 Hz ~) V 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 1 1/2 1 1/2 1 1/2 1 1/2 2Water flow l/s 0.8 0.9 1.2 1.4 1.9Water load loss kPa 40 45 40 35 45Airflow m3/h 7000 7800 11000 12500 16000air static pressure Pa 70 95 50 50 90Dimensions (length x width x height) mm 1130x800x1250 1130x800x1250 1700x870x1250 1700x870x1250 2000x939x1250Net weight Kg 277 282 376 416 567

MODEL 2002 2402 3002 3502

Nominal cooling capacity kW 49.0 60.6 71.2 80.4Nominal cooling capacity R.T. 13.9 17.2 20.2 22.9Power input – cooling kW 16.7 19.4 22.3 25.8Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 400.3+NWater connections Ø (") 2 2 2 2Water flow l/s 2.3 2.9 3.4 3.8Water load loss kPa 40 35 30 30Airflow m3/h 18000 18500 27000 32000air static pressure Pa 60 78 140 160Dimensions (length x width x height) mm 2150x980x1362 2150x980x1362 2800x1050x1722 2800x1050x1722Net weight Kg 651 687 1038 1120

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

HITECSA recommends the installation of an anti-freeze heater in the water collection tray for ambient temperatures of less than 5°C.

WA

TE

R C

HIL

LER

UN

ITS

Page 74: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

73

D06

EWCBZ TECHNICAL SPECIFICATIONS

MODEL 701 801 1001 1201 1602

Nominal cooling capacity kW 15.9 19.4 24.0 29.7 38.9Nominal cooling capacity R.T. 4.5 5.5 6.8 8.4 11.1Nominal heating capacity kW 17.4 21.3 26.4 32.6 42.5Power input – cooling kW 5.5 7.4 9.8 12.3 14.7Heating power input kW 5.0 5.8 7.5 8.8 11.7Power supply (50 Hz ~) V 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+NWater connections Ø (") 1 1/2 1 1/2 1 1/2 1 1/2 2Water flow l/s 0.8 0.9 1.1 1.4 1.9Water load loss kPa 40.0 45.0 40.0 35.0 45.0Airflow m3/h 7000 7800 11000 12500 16000air static pressure Pa 70 95 50 50 90Dimensions (length x width x height) mm 1130x800x1250 1130x800x1250 1700x870x1250 1700x870x1250 2000x939x1250Net weight Kg 277 282 376 416 567

MODEL 2002 2402 3002 3502

Nominal cooling capacity kW 48.0 59.4 69.8 78.5Nominal cooling capacity R.T. 13.6 16.9 19.8 22.3Nominal heating capacity kW 52.8 65.2 76.0 85.2Power input – cooling kW 19.6 24.4 26.1 30.3Heating power input kW 14.8 17.7 20.2 22.0Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 400.3+NWater connections Ø (") 2 2 2 2Water flow l/s 2.3 2.8 3.3 3.8Water load loss kPa 40 35 30 30Airflow m3/h 22000 23000 27000 32000air static pressure Pa 120 135 140 160Dimensions (length x width x height) mm 2600x980x1422 2600x980x1422 2800x1050x1722 2800x1050x1722Net weight Kg 807 863 1038 1120

ENERGY SAVING

Compressor soft-start(depending on models)

Fan soft-start(depending on models)

Condensation control for low outdoor

temperatures by frequency converter

SOUND LEVEL

Double thermo-acoustic insulation

Compressor sound jacket

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hzand voltages 230, 208, etc.

Outdoor installation kit

Upgraded motors

Anti-freeze resistanceoperation in collection tray

Fireproof filter class M0

Thermo-acoustic insulation class M0

Base guides

Anti-corrosion pre-treated coils

Prepared for disassembly

Outdoor reading pressure gauges

Multi-tube evaporatoroption on request

Outdoor inertia module, MWI

Discharge water temperatureunder 7ºC

Differential pressure switch

Vertical condenser air outlet

MAINTENANCE

Service valvesExternal Schrader valves for pressure test

Condenser filter

REGULATION AND CONTROL

Prepared for Hydrofan

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Option of master-slave operation

Operation for redundant machine

Centralised integrated management operation

Operation without neutral

Scheduling function and Modbus connection, etc. consultThermostat chapter

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

HITECSA recommends the installation of an anti-freeze heater in the water collection tray for ambient temperatures of less than 5°C.

Inertia modules for these units, consult commercial department

WA

TE

R C

HILLE

R U

NITS

Page 75: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

74

D07 WATER-TO-WATER SCROLL COMPRESSOR

ADVANCE WCooling only/Heat pump

MAIN FEATURESThe EWWF/EWWFB chiller unit range are units specially designed for indoor installation.

MODEL 50.2 60.2 80.2 90.2 120.2 150.2

Nominal cooling capacity (1) kW 51.1 61.3 77.6 91.4 118.8 147.5

Nominal cooling capacity (1) R.T. 14.5 17.4 22.1 26.0 33.8 41.9

Power input kW 11.9 13.6 17.3 20.8 26.6 33.0

EER kW/ kW 4.52 4.68 4.67 4.55 4.62 4.62

ESSER kW/ kW 6.450 6.62 6.11 6.59 6.24 5.95

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3

Water connections (IN/OUT) (3) Ø (") 2" 1/2 2" 1/2 2" 1/2 2" 1/2 2" 1/2 2" 1/2

Dimensions (length x width x height) mm 1210x850x1500 1210x850x1500 1210x850x1500 1210x850x1500 1210x850x1500 1210x850x1500

Net weight Kg 433 481 528 577 818 942

MODEL 20.1 25.1 30.1 35.1 40.1 45.1

Nominal cooling capacity (1) kW 21.3 26.4 31.3 35.1 39.5 46.9

Nominal cooling capacity (1) R.T. 6.1 7.5 8.9 10.0 11.2 13.3

Power input kW 4.4 5.5 6.4 7.2 8.2 9.7

EER kW/ kW 4.81 4.82 4.86 4.90 4.84 4.86

ESSER kW/ kW 5.44 5.43 5.41 5.38 5.21 5.44

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3

Water connections (IN/OUT) (3) Ø (") 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2

Dimensions (length x width x height) mm 821x455x1350 821x455x1350 821x455x1350 821x455x1350 821x455x1350 821x455x1350

Net weight Kg 156 176 174 179 185 203

EWWF cooling only TECHNICAL SPECIFICATIONS

• Cooling capacities ranging from 20 to 380 kW

• Scroll Compressors

• R410A refrigerant

• B energy rating

• Wide range of hydraulic kits

• Heat recovery

• DHW function

• Victaulic connections inside the unit

• The condenser and evaporator are welded plate exchangers

• 2 versionsSuper-silent (SS)Remote Condenser (CR)

• Standard liquid visor

• Standard differential pressure switch

Water/water units: high performance in reduced format

WATER CHILLER UNITS

WA

TE

R C

HIL

LER

UN

ITS

Page 76: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

75

D07

MODEL 270.4 290.4 340.4 390.4Nominal cooling capacity (1) kW 266.4 296.0 338.7 379.9Nominal cooling capacity (1) R.T. 75.7 84.2 96.3 108.0Power input kW 57.9 64.1 73.4 81.6EER kW/ kW 4.6 4.6 4.6 4.7ESSER kW/ kW 6.21 5.92 6.10 6.05Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3Water connections (IN/OUT) (3) Ø (") 4" 4" 4" 4"Dimensions (length x width x height) mm 2250x855x1850 2250x855x1850 2250x855x1850 2250x855x1850Net weight Kg 1369 1466 1552 1644

MODEL 170.2 200.2 210.4 240.4Nominal cooling capacity (1) kW 170.5 193.3 209.6 233.4Nominal cooling capacity (1) R.T. 48.5 55.0 59.6 66.4Power input kW 37.7 42.8 45.8 51.2EER kW/ kW 4.67 4.67 4.58 4.56ESSER kW/ kW 6.05 6.04 6.62 6.00Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3Water connections (IN/OUT) (3) Ø (") 2" 1/2 2" 1/2 2" 1/2 2" 1/2Dimensions (length x width x height) mm 1210x850x1500 1210x850x1500 2250x855x1850 2250x855x1850Net weight Kg 1013 1113 1213 1382

(1) Eurovent cooling mode conditions: Evaporator: water inlet 12ºC, water outlet 7ºC. Condenser: water inlet 30ºC, water outlet 35ºC.(3) Victaulic type connections.

EWWF cooling only TECHNICAL SPECIFICATIONS

MODEL 20.1 25.1 30.1 35.1 40.1 45.1Nominal cooling capacity (1) kW 20.9 26.1 30.3 34.2 38.4 45.8Nominal cooling capacity (1) R.T. 5.9 7.4 8.6 9.7 10.9 13.0Power input kW 4.5 5.5 6.5 7.3 8.3 9.8EER 4.65 4.73 4.65 4.67 4.65 4.65ESSER 5.16 5.37 5.26 5.26 5.05 5.19Nominal heating capacity (2) kW 23.7 28.9 33.6 38.5 42.9 51.2Power input kW 5.7 6.9 8.1 9.2 10.3 12.2

COP 4.19 4.19 4.17 4.18 4.17 4.20

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3Water connections (IN/OUT) (3) Ø (") 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2 1" 1/2Dimensions (length x width x height) mm 821x455x1350 821x455x1350 821x455x1350 821x455x1350 821x455x1350 821x455x1350

Net weight Kg 159 181 179 184 190 208

MODEL 50.2 60.2 80.2 90.2 120.2 150.2Nominal cooling capacity (1) kW 50.2 59.2 76.4 89.0 115.3 144.8Nominal cooling capacity (1) R.T. 14.3 16.8 21.7 25.3 32.8 41.2Power input kW 12.0 13.9 17.4 21.1 27.0 33.3EER 4.40 4.45 4.57 4.38 4.43 4.51ESSER 6.200 6.23 5.99 6.20 5.85 5.76Nominal heating capacity (2) kW 57.4 67.9 86.0 101.8 131.6 163.7Power input kW 13.7 16.5 20.3 24.3 31.3 38.5COP 4.190 4.12 4.24 4.19 4.20 4.25Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3Water connections (IN/OUT) (3) Ø (") 2" 1/2 2" 1/2 2" 1/2 2" 1/2 2" 1/2 2" 1/2Dimensions (length x width x height) mm 1210x850x1500 1210x850x1500 1210x850x1500 1210x850x1500 1210x850x1500 1210x850x1500Net weight Kg 441 489 539 588 831 959

EWWFB (heat pump) TECHNICAL SPECIFICATIONS

MODEL 170.2 200.2 210.4 240.4Nominal cooling capacity (1) kW 166.3 186.1 205.2 226.2Nominal cooling capacity (1) R.T. 47.3 52.9 58.3 64.3Power input kW 38.2 43.4 46.6 52.3EER 4.52 4.44 4.40 4.33ESSER 5.96 5.66 6.50 5.92Nominal heating capacity (2) kW 189.5 211.6 231.0 255.5Power input kW 44.8 50.1 56.2 63.2COP 4.23 4.22 4.11 4.04Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3Water connections (IN/OUT) (3) Ø (") 2" 1/2 2" 1/2 2" 1/2 2" 1/2Dimensions (length x width x height) mm 1210x850x1500 1210x850x1500 2250x855x1850 2250x855x1850Net weight Kg 1031 1130 1244 1414

(1) Eurovent cooling mode conditions: Evaporator: water inlet 12ºC, water outlet 7ºC. Condenser: water inlet 30ºC, water outlet 35ºC. (2) Eurovent heating mode conditions: Evaporator: water inlet 10ºC, water outlet 7ºC. Condenser: water inlet 40ºC, water outlet 45ºC. (3) Victaulic type connections.

WA

TE

R C

HILLE

R U

NITS

Page 77: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

76

D07

ENERGY SAVINGCondensation controlCompressor soft-startCondensers for correction of the power factorElectronic expansion valveHeat recovery

SOUND LEVELCompressor sound jacket

UNIT INSTALLATIONBuilt-in hydronic kit with1 or 2 pumps Electric heater

Temperature sensor for DHW tankInlet/outlet valvePressostatic valve for well waterOutdoor air temperature sensor for outdoor condition compensationDifferential pressure switch3-way valve for DHW productionWater filterAnti-vibration supports for unit assembly

MAINTENANCEPressure gauge kit

REGULATION AND CONTROLModbus communicationON/OFF remote controlRemote panelSequencer for installations up to 4 unitsFlow switch

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

(1) Eurovent cooling mode conditions: Evaporator: water inlet 12ºC, water outlet 7ºC. Condenser: water inlet 30ºC, water outlet 35ºC. (2) Eurovent heating mode conditions: Evaporator: water inlet 10ºC, water outlet 7ºC. Condenser: water inlet 40ºC, water outlet 45ºC. (3) Victaulic type connections.

EWWFB (heat pump) TECHNICAL SPECIFICATIONS

MODEL 270.4 290.4 340.4 390.4Nominal cooling capacity (1) kW 263.7 292.0 332.6 371.2Nominal cooling capacity (1) R.T. 75.0 83.0 94.6 105.5Power input kW 58.5 65.0 74.7 83.6EER 4.51 4.49 4.45 4.44ESSER 6.10 5.84 6.02 5.95Nominal heating capacity (2) kW 294.9 330.1 375.8 417.6Power input kW 71.20 79.40 90.70 101.20COP 4.14 4.16 4.14 4.13Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3Water connections (IN/OUT) (3) Ø (") 4" 4" 4" 4"Dimensions (length x width x height) mm 2250x855x1850 2250x855x1850 2250x855x1850 2250x855x1850Net weight Kg 1405 1513 1597 1688

Complete hydraulic circuit with hydronic kit with double pump and inertia tank. For simpler versions, consult the commercial department.

HYDRAULIC DIAGRAMS EWWF/EWWFB

REGULATION AND CONTROLA. Differential pressure switchB. Water inlet temperature sensorC. Water inlet temperature sensorD. Air purgerE. ThermometerF. Safety valve.... Inside the unitO. Sensors

COMPONENTS1C. Outdoor exchanger1E. Indoor exchanger2. Pump3. Water filter4. Expansion vessel5. Water outlet6. Water inlet7. Damper valve8. Flexible connection9. Bypass valve10. Check valve11. Drainage/pressure connection

WA

TE

R C

HIL

LER

UN

ITS

Page 78: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

77

D08WATER TO WATER SCREW COMPRESSOR

ADVANCE WTCooling only

• Cooling capacities ranging from 300 to 1,100 kW

• R134A refrigerant

• 2 independent circuits with 1 screw compressor per circuit

• 3 versions availableSilent (SI)Super-silent (SS)Remote Condenser (CR)

MAIN FEATURES

The EWWFD chiller unit range is made up of high performance units. They are ideal for installations in continuous use or with high thermal demands.

MODEL 270.2 360.2 440.2 530.2 560.2 600.2

Nominal cooling capacity (1) kW 271.8 362.4 440.0 529.3 564.7 600.0

Nominal cooling capacity (1) R.T. 77.3 103.0 125.1 150.5 160.6 170.6

Power input (2) kW 68.0 82.1 102.0 121.0 129.0 138.0

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3

ESEER kW/kW 4.00 4.41 4.28 4.36 4.35 4.34

Evaporator

Water flow l/s 13.0 17.3 21.0 25.3 27.0 28.7

Pressure drop kPa 44.4 54.4 53.7 42.2 40.5 45.7

Water connection (IN/OUT) Ø (") 5 6 6 6 6 6

Condenser

Water flow l/s 8.0 10.5 12.7 15.3 16.4 17.4

Pressure drop kPa 28.7 38.7 41.0 40.1 45.7 41.6

Water connection (IN/OUT) Ø (") 2" 1/2 3 3 3 3 3

Sound level at 1 m dB (A) 70 70 71 71 71 71

Dimensions (length x width x height) mm 3795x950x1910 3795x950x1910 4210x1400x2050 4210x1400x2050 4210x1400x2050 4210x1400x2050

Net weight Kg 2067 2554 3005 3377 3470 3498

EWWFD cooling only TECHNICAL SPECIFICATIONS

Water/water units with screw compressor. Robustness and performance for the installations

WATER CHILLER UNITS

(1) Data calculated at water temperature in evaporator 12/7ºC and water temperature in condenser 30/35ºC.

WA

TE

R C

HILLE

R U

NITS

Page 79: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

78

D08

ENERGY SAVING

Compressor soft-start

Power factor correction

Electronic expansion valve

UNIT INSTALLATION

Water filter

Anti-vibration support for assembly of the unit

Phase fault control

Electronic expansion valve

Water flow switch

Compressor intake valves

Compressor liquid injection valves

Compress oil flow control

MAINTENANCE

High and low pressure gauges

REGULATION AND CONTROL

Integration with BMS applications

ON/OFF remote control

Remote control panel

Sequencer up to 4 units GSM

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

(1) Data calculated at water temperature in evaporator 12/7ºC and water temperature in condenser 30/35ºC.

MODEL 640.2 680.2 720.2 780.2 840.2 900.2

Nominal cooling capacity (1) kW 639.2 678.4 716.0 784.4 841.7 898.9

Nominal cooling capacity (1) R.T. 181.7 192.9 203.6 223.0 239.3 255.6

Power input (2) kW 145.0 153.0 168.0 182.0 194.0 206.0

Power supply (50 Hz ~) V 400.3 400.3 400.3 400.3 400.3 400.3

ESEER kW/ kW 4.38 4.41 4.25 4.29 4.32 4.36

Evaporator

Water flow l/s 30.5 32.4 34.2 37.5 40.2 42.9

Pressure drop kPa 56.3 63.4 70.6 52.8 60.8 65.7

Water connection (IN/OUT) Ø (") 6 6 6 8 8 8

Condenser

Water flow l/s 18.5 19.6 20.8 22.8 24.4 26.0

Pressure drop kPa 47.0 50.2 50.5 60.5 29.0 33.0

Water connection (IN/OUT) Ø (") 3 3 3 3 4 4

Sound level at 1 m dB (A) 71 71 71 72 72 73

Dimensions (length x width x height) mm 4210x1400x2050 4210x1400x2050 4210x1400x2050 4770x1400x2050 4770x1400x2050 4770x1400x2050

Net weight Kg 3592 3605 4029 4952 4970 4986

MODEL 960.2 1020.2 1120.2

Nominal cooling capacity (1) kW 962.1 1040.2 1118.2

Nominal cooling capacity (1) R.T. 273.6 295.8 317.9

Power input (2) kW 218.7 230.5 242.3

Power supply (50 Hz ~) V 400.3 400.3 400.3

ESEER kW/ kW 4.40 4.51 4.61

Evaporator

Water flow l/s 46.0 49.7 53.4

Pressure drop kPa 75.3 88.0 101.7

Water connection (IN/OUT) Ø (") 8 8 8

Condenser

Water flow l/s 28.2 30.4 32.5

Pressure drop kPa 38.7 41.7 47.9

Water connection (IN/OUT) Ø (") 4 4 4

Sound level at 1 m dB (A) 74 74 74

Dimensions (length x width x height) mm 4770x1400x2050 4770x1400x2050 4770x1400x2050

Net weight Kg 5112 5165 5342

EWWFD cooling only TECHNICAL SPECIFICATIONS

WA

TE

R C

HIL

LER

UN

ITS

Page 80: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

79

EFCW/FCCW, 2T and 4T vertical and horizontal fan coil with and without housing Page 80

FKW and FKWS, 4-way 2T and 4T cassette fan coil Page 84

FPW, wall mounted fan coil Page 86

BSW, fan coil installation high pressure ducts available Page 87

BHW, ductable fan-coil Page 90

EHW, horizontal air conditioning units Page 92

CLW, indoor units for connection to vertical ducts Page 94

EHWM, air handling units Page 96

FAN COILSAND AHUS

Page 81: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

80

E01 CENTRIFUGAL FAN COIL

• Cooling capacities ranging from 0.9 to 11 kW

• Can be combined with all the KRONO and ADVANCE chilling unit range

• Horizontal or vertical configuration

• Version with or without housing

• 4 installation versions: FCW 3R: without housing with 2 tubesFCCW 3R: with housing with 2 tubesFCW 3R+1: without housing with 4 tubesFCCW 3R+1: with housing with 4 tubes

• Different air discharge or intake options:FCCW: vertical V versionFCCW: horizontal H versionFCW: vertical V versionFCW: horizontal H version

MAIN FEATURES

The FCW-FCCW fan coil is a terminal with a centrifuge fan. It is characterised by its modern design and can be installed in any environment.

Water terminal units for the hotel and tertiary sector

WATER TERMINAL UNITS

FCWWithout housing

FCCWWith housing

MODEL 10 15 20 25 30 40

Water cooling capacity kW 0.9 1.3 2.2 2.5 3.1 3.5

Water cooling capacity R.T. 0.2 0.4 0.6 0.7 0.9 1.0

Water heating capacity 50ºC kW 1.3 1.9 2.6 3.3 3.7 4.5

Water heating capacity 70/60ºC kW 2.2 3.2 4.4 5.5 6.2 7.5

Power input W 30 30 40 50 60 80

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 230.1

Airflow (1) m3/h 227 289 404 453 575 685

Water flow l/h 148 220 373 435 535 662

Water connections Ø (") 3/4 3/4 3/4 3/4 3/4 3/4

Sound pressure (2) db(A) 37 36 35 38 38 43

Weight Kg 15.6 18.9 23.7 23.9 27.7 27.9

Dimensions (length x height x width) (2) mm 480x660x225 480x860x225 480x1060x225 480x1060x225 480x1260x225 480x1260x225

FCW 3R / FCCW 3R (2 tubes) TECHNICAL SPECIFICATIONS

FAN

CO

ILS

AN

D A

HU

S

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS

Page 82: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

81

E01

ENERGY SAVING

DC brushless motor

UNIT INSTALLATION

Motor powered at 60 Pa

2-tube model 3-way valve

2-tube model shut-off

and regulation valve

4-tube model 3-way valve

4-tube model shut-off and regulation valve

Auxiliary condensation tray

Support baseboard

REGULATION AND CONTROL

Electronic thermostat

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

FCW 3R+1 / FCCW 3R+1 (4 tubes) TECHNICAL SPECIFICATIONS

(1) available static pressure 0 Pa(2) Considered 8.6 dB(A) lower with regard to the sound level of a 90 m3 premises with a reverberation time of 0.5 sec.

Data calculated at maximum speed

(1) Available static pressure 0 Pa(2) Considered 8.6 dB(A) lower with regard to the sound level of a 90 m3 premises with a reverberation time of 0.5 sec.

Data calculated at maximum speed

FCW 3R / FCCW 3R (2 tubes) TECHNICAL SPECIFICATIONS

MODEL 50 60 70 80 100 110

Water cooling capacity kW 4.1 5.6 6.9 8.0 10.0 11.0

Water cooling capacity R.T. 1.2 1.6 2.0 2.3 2.8 3.1

Water heating capacity 50ºC kW 5.1 6.7 8.1 10.1 13.1 13.3

Water heating capacity 70/60ºC kW 8.6 11.3 13.7 16.9 22.0 23.8

Power input W 70 160 180 213 277 273

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 230.1

Airflow (1) m3/h 708 1,058 1,242 1,356 2,012 2,003

Water flow l/h 745 961 1,187 1,376 1,727 1,898

Water connections Ø (") 3/4 3/4 3/4 3/4 3/4 3/4

Sound pressure (2) db(A) 43 49 55 54 58 57

Weight Kg 32.7 38.0 38.5 50.0 58.5 59.0

Dimensions (length x height x width) (2) mm 585x1260x225 585x1460x225 585x1460x225 602x1660x257 602x1960x257 602x1960x257

MODEL 10 15 20 25 30 40

Water cooling capacity kW 0.8 1.2 20.8 2.4 2.8 3.7

Water cooling capacity R.T. 0.2 0.3 5.9 0.7 0.8 1.0

Water heating capacity 70/60ºC kW 1.3 1.9 2.7 2.9 3.5 4.1

Power input W 30 30 40 56 60 80

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 230.1

Airflow (1) m3/h 216 275 384 430 546 651

Water flow l/h 144 212 358 409 509 635

Water connections Ø (") 3/4 3/4 3/4 3/4 3/4 3/4

Sound pressure (2) db(A) 36 38 35 38 37 44

Weight Kg 15.6 18.9 23.7 23.9 27.7 27.9

Dimensions (length x height x width) (2) mm 480x660x225 480x860x225 480x1060x225 480x1060x225 480x1260x225 480x1260x225

MODEL 50 60 70 80 100 110

Water cooling capacity kW 4.5 2.4 6.6 7.7 9.7 10.7

Water cooling capacity R.T. 1.3 0.7 1.9 2.2 2.8 3.0

Water heating capacity 70/60ºC kW 5.0 6.2 7.7 8.4 10.1 11.4

Power input W 78 160 180 182 273 273

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1 230.1 230.1

Airflow (1) m3/h 673 1,005 1,180 1,291 1,916 1,908

Water flow l/h 769 920 1,130 1,330 1,673 1,837

Water connections Ø (") 3/4 3/4 3/4 3/4 3/4 3/4

Sound pressure (2) db(A) 44 50 56 54 58 58

Weight Kg 32.7 38.0 38.5 50.0 58.5 59.0

Dimensions (length x height x width) (2) mm 585x1260x225 585x1460x225 585x1460x225 602x1660x257 602x1960x257 602x1960x257

FAN

CO

ILS A

ND

AH

US

Page 83: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

82

E01 OPTIONS AVAILABLE

FAN

CO

ILS

AN

D A

HU

S

Discharge plenum for unitswithout housing

Adjustable discharge air grille for units with housing

Fan coil support set Auxiliary condensation tray

90° discharge plenum for units without housing

Return air plenum for units without housing

Extension for straight and 90° plenums for units without housing

Tubular discharge plenum for units without housing

Tubular return air plenum with filter for units without housing

Painted lower panel without grillefor units with housing

Painted lower panel with filter and grille for units with housing

Condensate pump Painted ceiling panel + 90º return air and discharge plenum for units without housing

Electric heaters Including safety thermostat

For models kW

FCW 2 1

FCW 3 and 4 1

FCW 5 – 7 2

FCW 8 and 9 3

FCW 10 0.6

FCW 11 and 12 4

FTW 1 and 2 1

FTW 3 1

FTW 4 2

FTW 6 3

Page 84: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

83

E01OPTIONS AVAILABLE

COMPONENTS

A. Valve + actuatorB. Connection elbowsC. Shut-off/ regulation valve

IMPORTANT NOTE:

Elbow connections are not supplied with the valves. Please order separately.

For models DESCRIPTION Ø “

FCW 1-6 and FTW 10-60 2 tube-3-way system 1/2

FCW 1-6 and FTW 10-60 2-tube-3-way, 3-point floating system 1/2

FCW 1-6 and FTW 10-60 2-tube-3-way, 0-10 V modulating system 1/2

FCW 1-6 and FTW 10-60 4 tube-3-way system 1/2 – 1/2

FCW 1-6 and FTW 10-60 4-tube-3-way, 3-point floating system 1/2 – 1/2

FCW 1-6 and FTW 10-60 4-tube-3-way, 0-10 V modulating system 1/2 – 1/2

FCW 1-6 and FTW 10-60 2 tube-2-way system 1/2

FCW 1-6 and FTW 10-60 2-tube-3-way, 3-point floating system 1/2

FCW 1-6 and FTW 10-60 2-tube-3-way, 0-10 V modulating system 1/2

FCW 1-6 and FTW 10-60 4 tube-2-way system 1/2 – 1/2

FCW 1-6 and FTW 10-60 4-tube-3-way, 3-point floating system 1/2 – 1/2

FCW 1-6 and FTW 10-60 4-tube-3-way, 0-10 V modulating system 1/2 – 1/2

FCW 1-6 and FTW 10-60 Shut-off/flow regulation valve. 2 tube system. 1/2

FCW 1-6 and FTW 10-60 Shut-off/flow regulation valve. 4 tube system. 1/2 – 1/2

FCW 1-6 and FTW 10-60 2 shut-off valves. 2 tube system. 1/2

FCW 1-6 and FTW 10-60 2 shut-off valves. 4 tube system. 1/2 – 1/2

FCW 1-6 and FTW 10-60 Elbow connections 2 tube system. -

FCW 1-6 and FTW 10-60 Elbow connections 4 tube system. -

FCW 70-90 2 tube-3-way system 3/4

FCW 70-90 2-tube-3-way, 3-point floating system 3/4

FCW 70-90 2-tube-3-way, 0-10 V modulating system 3/4

FCW 70-90 4 tube-3-way system 3/4 – 3/4

FCW 70-90 4-tube-3-way, 3-point floating system 3/4 – 3/4

FCW 70-90 4-tube-3-way, 0-10 V modulating system 3/4 – 3/4

FCW 70-90 2 tube-2-way system 3/4

FCW 70-90 2-tube-2-way, 3-point floating system 3/4

FCW 70-90 2-tube-2-way, 0-10 V modulating system 3/4

FCW 70-90 4 tube-2-way system 3/4 – 3/4

FCW 70-90 4-tube-2-way, 3-point floating system 3/4 – 3/4

FCW 70-90 4-tube-2-way, 0-10 V modulating system 3/4 – 3/4

FCW 70-90 Shut-off/flow regulation valve. 2 tube system. 3/4

FCW 70-90 Shut-off/flow regulation valve. 4 tube system. 3/4 – 3/4

FCW 70-90 2 shut-off valves. 2 tube system. 3/4

FCW 70-90 2 shut-off valves. 4 tube system. 3/4 – 3/4

FCW 70-90 Elbow connections 2 tube system. -

FCW 70-90 Elbow connections 4 tube system. -

For models DESCRIPTION Ø “

FCW 100-120 2 tube-3-way system 1

FCW 100-120 2-tube-3-way, 3-point floating system 1

FCW 100-120 2-tube-3-way, 0-10 V modulating system 1 – 3/4

FCW 100-120 4 tube-3-way system 1 – 3/4

FCW 100-120 4-tube-3-way, 3-point floating system 1 – 3/4

FCW 100-120 4-tube-3-way, 0-10 V modulating system 1

FCW 100-120 2 tube-2-way system 1

FCW 100-120 2-tube-2-way, 3-point floating system 1

FCW 100-120 2-tube-2-way, 0-10 V modulating system 1 – 3/4

FCW 100-120 4 tube-2-way system 1 – 3/4

FCW 100-120 4-tube-2-way, 3-point floating system 1 – 3/4

FCW 100-120 4-tube-2-way, 0-10 V modulating system 1

FCW 100-120 Shut-off/flow regulation valve. 2 tube system. 1 – 3/4

FCW 100-120 Shut-off/flow regulation valve. 4 tube system. 1

FCW 100-120 2 shut-off valves. 2 tube system. 1 – 3/4

FCW 100-120 2 shut-off valves. 4 tube system. -

FCW 100-120 Elbow connections 2 tube system. -

FCW 100-120 Elbow connections 4 tube system. -

OTHER ACCESSORIES

Outdoor air damperRear closing panel for units with housingDischarge grilles for units with housingOther accessories: consult commercial department

FAN

CO

ILS A

ND

AH

US

Page 85: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

84

E02

Without infrared controller

With infrared controller

FAN

CO

ILS

AN

D A

HU

S

FAN COIL CASSETTE

• Cooling capacities ranging from 2.4 to 7.6 kW

• EUROVENT certification

• 2 versions:FKW (with its own infrared controller)FKWS (without controller and ready for installation

with a wall mounted controller)

• 2 measurements: 580x580 and 835x835 mm

• Extractable filter. Easy maintenance

• Valves not installed. Supplied separately.

• Condensate drainage pump incorporated

• Connection tubes supplied separately.

MAIN FEATURES

The fan coil cassette is a terminal to treat the air of an envir-on ment, either in the winter or in the summer Especially designed with the standard measurements of installations in false ceilings.

Units can be integrated into technical ceiling for tertiary sectorFKW

FKWS

FKW Model with control FKWS Model without control. Installation with 2 tubes. TECHNICAL SPECIFICATIONS

MODEL 21 22 23 24

Water cooling capacity 7/12ºC kW 2.4 2.8 3.3 4.5

Water cooling capacity 7/12ºC R.T. 0.7 0.8 0.9 1.3

Water heating capacity 50ºC kW 3.4 3.8 4.5 5.3

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Standard coil water connections Ø (") 3/4 3/4 3/4 3/4

Sound pressure (1) db(A) 50 50 53 55

Weight Kg 23.5 24.5 24.5 24.5

Dimensions (length x height x width) mm 580x580x280+23 580x580x280+23 580x580x280+23 580x580x280+23

MODEL 31 32 33 34

Water cooling capacity 7/12ºC kW 5.6 6.4 7.1 7.6

Water cooling capacity 7/12ºC R.T. 1.6 1.8 2.0 2.2

Water heating capacity 50ºC kW 7.3 7.3 8.0 8.3

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Standard coil water connections Ø (") 3/4 1 1 1

Sound pressure (1) db(A) 47 49 52 52

Weight Kg 37 43 43 45

Dimensions (length x height x width) mm 835x835x240+60 835x835x305+60 835x835x305+60 835x835x305+60

WATER TERMINAL UNITS

Page 86: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

85

E02

FAN

CO

ILS A

ND

AH

US

FKW Model with control FKWS Model without control. Installation with 4 tubes. TECHNICAL SPECIFICATIONS

MODEL 41 42 43 44

Water cooling capacity 7/12ºC kW 1.9 2.8 3.5 4.4

Water cooling capacity 7/12ºC R.T. 0.5 0.8 1.0 1.3

Water heating capacity 60/70ºC kW 1.9 2.8 3.5 4.4

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Standard coil water connections Ø (") 3/4 3/4 3/4 3/4

Auxiliary coil water connections Ø (") 1/2 1/2 1/2 1/2

Sound pressure (1) db(A) 50 50 53 55

Weight Kg 23.5 24.5 24.5 24.5

Dimensions (length x height x width) mm 580x580x280+23 580x580x280+23 580x580x280+23 580x580x280+23

MODEL 51 52 53 54

Water cooling capacity 7/12ºC kW 4.3 5.0 5.5 6.1

Water cooling capacity 7/12ºC R.T. 1.2 1.4 1.5 1.7

Water heating capacity 70/60ºC kW 5.9 6.6 7.3 8.6

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Standard coil water connections Ø (") 3/4 1 1 1

Auxiliary coil water connections Ø (") 1/2 3/4 3/4 3/4

Sound pressure (1) db(A) 47 49 52 52

Weight Kg 37 43 43 45

Dimensions (length x height x width) mm 835x835x240+60 835x835x305+60 835x835x305+60 835x835x305+60

UNIT INSTALLATION

2-tube model 3-way valve

2-tube model shut-off and regulation valve

Elbow connections for 2-tube installation

4-tube model 3-way valve

4-tube model shut-off and regulation valve

Elbow connections for 4-tube installation

REGULATION AND CONTROL

Wall mounted electronic thermostat

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

(1) Considered 8.6 dB(A) lower with regard to the sound level of a 90 m3 premises with a reverberation time of 0.5 sec. Data calculated at maximum speed

Page 87: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

86

E03

FAN

CO

ILS

AN

D A

HU

S

Solutions for small demands difficult to locate

FPW

FPW TECHNICAL SPECIFICATIONS

MODEL 20 25 35 40

Cooling capacity (1) kW 2.0 2.4 3.3 4.0

Cooling capacity (1) R.T. 0.6 0.7 0.9 1.1

Heating capacity (2) kW 2.6 3.0 4.4 4.9

Heating capacity (3) kW 4.4 5.0 7.5 8.3

Power input W 29 29 48 51

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Water flow l/h 336 409 573 686

Water connections Ø (") 1/2 1/2 1/2 1/2

Sound pressure (4) db(A) 45 45 45 48

Dimensions (length x height x width) mm 880x298x205 990x305x210 1172x360x220 1172x360x220

Weight Kg 11.5 12.4 19 20.5

(1) Water inlet 7ºC, water outlet 12ºC. Air temperature 27ºC dry bulb, 19ºC wet bulb(2) Water inlet 50ºC. Air temperature 20ºC(3) Water inlet 60/70ºC. Air temperature 20ºC(4) Considered 8.6 dB(A) lower with regard to the sound level of a 90 m3 premises with a reverberation time of 0.5 sec.Data calculated at maximum speedavailable static pressure 0 Pa

MAIN FEATURES

• Cooling capacities ranging from 1.5 to 4.0 kW

• Easy maintenance

• Valves integrated in the unit

• 4 versions:FPW (with its own infrared controller)FPWS (without controller and ready for installation

with a wall mounted controller)FPW+V3 (with infrared controller and with a 3-way

valve)FPWS+V3 (without controller and with a 3-way valve)

The fan coil wall mounted units is a terminal to treat the air of an environment, in both the winter and the summer. It offers an attractive design and excellent comfort with a minimum noise level.

WALL MOUNTED FAN COIL

WATER TERMINAL UNITS

Page 88: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

87

E04

FAN

CO

ILS A

ND

AH

US

FAN COIL HIGH PRESSURE

WATER TERMINAL UNITS

• Cooling capacities ranging from 3.6 to 50.6 kW

• High pressure available: from 105 Pa

• Standard model without filter. EU3 filter optional

• 2 versions: BSW H (horizontal installation) and BSW V (vertical installation)

• Easy maintenance

MAIN FEATURES

Ducted fan coil units are designed with a low profile, making them ideal for installation in false ceilings.

Flexible and adaptable applications for water installations.

BSWHigh pressure

BSW H/BSW V (2 tubes) TECHNICAL SPECIFICATIONS

MODEL 10 20 30 40

Cooling capacity (1) kW 3.8 7.1 9.2 10.6

Cooling capacity (1) R.T. 2.8 5.7 8.5 11.4

Heating capacity (2) kW 5.0 8.6 11.3 12.9

Maximum power input W 155 195 325 355

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Airflow m3/h 895 1423 1951 2131

Available pressure Pa 105 105 135 135

Water flow l/h 606.5 1092.2 1489.1 1684.3

Water connections Ø (") 1/2 1/2 3/4 3/4

Sound pressure (3) db(A) 59.4 57.4 61.4 60.4

Dimensions (length x height x width) H mm 650x300x533 1000x300x533 1100x325x533 1340x325x533

Dimensions (length x height x width) V mm 738x330x603 1088x330x603 1188x355x623 1428x355x623

Weight Kg 28 36 41 46

MODEL 50 60 70

Cooling capacity (1) kW 13.1 27.8 50.6

Cooling capacity (1) R.T. 3.7 7.9 14.4

Heating capacity (2) kW 17.0 32.9 60.9

Maximum power input W 525 1300 2400

Power supply (50 Hz ~) V 230.1 230.1 230.1

Airflow m3/h 3002 4678 9250

Available pressure Pa 205 260 260

Water flow l/h 1945.0 4234.6 7802.1

Water connections Ø (") 1 1 1/4 1 1/2

Sound pressure (3) db(A) 66.4 69.4 72.4

Dimensions (length x height x width) mm 1340x375x533 1341x675x853 2028x675x853

Dimensions (length x height x width) V mm 1428x405x723 1481x703x1294 2168x703x1294

Weight Kg 57 117 192

(1) Water inlet 7ºC, water outlet 12ºC. Air temperature 27ºC dry bulb, 19ºC wet bulb(2) Water inlet 50ºC. Air temperature 20ºC(3) Considered 8.6 dB(A) lower with regard to the sound level of a 90 m3 premises with a reverberation time of 0.5 sec.Data calculated at maximum speed

Page 89: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

88

E04

AIR QUALITY

Air filter

UNIT INSTALLATION

2-tube model 3-way valve

2-tube model shut-off and regulation valve

Elbow connections for 2-tube installation

4-tube model 3-way valve

4-tube model shut-offand regulation valve

Elbow connections for 4-tube installation

Hot water heating coil

Electric heater

Condensation tray

REGULATION AND CONTROL

Wall mounted electronic thermostat

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

BSW H/BSW V (4 tubes) TECHNICAL SPECIFICATIONS

MODEL 10 20 30 40

Cooling capacity (1) kW 3.6 7.0 9.0 9.6

Cooling capacity (1) R.T. 1.0 2.0 2.6 2.7

Heating capacity (2) kW 4.2 7.0 9.2 10.6

Maximum power input W 155 195 325 355

Power supply (50 Hz ~) V 230.1 230.1 230.1 230.1

Airflow m3/h 795 1353 1850 2025

Available pressure Pa 95 90 120 120

Water flow l/h 606.5 1092.2 1489.1 1684.3

Water connections Ø (") 1/2 1/2 3/4 3/4

Sound pressure (3) db(A) 60.4 57.4 61.4 61.4

Dimensions (length x height x width) H mm 650x300x533 1000x300x533 1100x325x533 1340x325x533

Dimensions (length x height x width) V mm 738x330x603 1088x330x603 1188x355x623 1428x355x623

Weight Kg 28 36 41 46

MODEL 50 60 70

Cooling capacity (1) kW 13.6 24.9 45.5

Cooling capacity (1) R.T. 3.9 7.1 12.9

Heating capacity (2) kW 12.7 38.8 70.2

Maximum power input W 525 1300 2400

Power supply (50 Hz ~) V 230.1 230.1 230.1

Airflow m3/h 3036 4445 8788

Available pressure Pa 180 220 220

Water flow l/h 1945.0 4234.6 7802.1

Water connections Ø (") 1 1 1/4 1 1/2

Sound pressure (3) db(A) 64.4 69.4 72.4

Dimensions (length x height x width) H mm 1340x375x533 1341x675x853 2028x675x853

Dimensions (length x height x width) V mm 1428x405x723 1481x703x1294 2168x703x1294

Weight Kg 57 117 192

FAN

CO

ILS

AN

D A

HU

S

(1) Water inlet 7ºC, water outlet 12ºC. Air temperature 27ºC dry bulb, 19ºC wet bulb(2) Water inlet 60/70ºC. Air temperature 20ºC

Page 90: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

89

E04OPTIONS AVAILABLE

OTHER OPTIONAL ACCESSORIES

Coils 4rCoils 5rCoils 6rAir renewal dampersDischarge plenumReturn plenum

Valves, 2 and 4 tube installationsVALVE MODEL BSW 10 Ø (“) BSW 20 Ø (“) BSW 30 A 50 Ø (“) BSW 60 Ø (“) BSW 70 Ø (“)

2 tube system – 3 way 1/2 3/4 1 1 1/2 2

2 tube system – 3-way, 3-point floating 1/2 3/4 1 1 1/2 2

2 tube system – 3-way, 0-10 V modulating 1/2 3/4 1 1 1/2 2

4 tube system – 3 way 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

4 tube system – 3-way, 3-point floating 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

4 tube system – 3-way, 0-10 V modulating 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

2 tube system – 2 way 1/2 3/4 1 1 1/2 2

2 tube system – 2-way, 3-point floating 1/2 3/4 1 1 1/2 2

2 tube system – 2-way, 0-10 V modulating 1/2 3/4 1 1 1/2 2

4 tube system – 2 way 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

4 tube system – 2-way, 3-point floating 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

4 tube system – 2-way, 0-10 V modulating 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

Shut-off/flow regulation valve. 2 tube system. 1/2 3/4 1 1 1/2 2

Shut-off/flow regulation valve. 4 tube system. 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

2 shut-off valves. 2 tube system. 1/2 3/4 1 1 1/2 2

2 shut-off valves. 4 tube system. 1/2 – 1/2 3/4 – 1/2 1 – 3/4 1 1/2 – 1 1/2 2 – 1 1/2

Connection pipe for 2 tube system - - - - -

Connection pipe for 4 tube system - - - - -

FAN

CO

ILS A

ND

AH

US

COMPONENTS

A. Valve + actuatorB. Connection pipeC. Shut-off/ regulation valve

IMPORTANT NOTE:

Elbow connections are not supplied with the valves. Please order separately.

Auxiliary condensation tray Air filter Condensate pump.

Auxiliary hot water coils1r for 4t systems

Electric heaters

For models kWBSW 10 3BSW 10 4.5BSW 20 6BSW 20 6BSW 30 9BSW 30 9BSW 40 9BSW 40 9BSW 50 12BSW 50 12BSW 60 12BSW 60 18BSW 70 18BSW 70 24

For models kW

BSW 10 4.2

BSW 20 7

BSW 30 9.2

BSW 40 10.5

BSW 50 14

BSW 60 38.8

BSW 70 70.2

Page 91: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

90

E05 DUCTABLE AIR CONDITIONING UNITS

• Cooling capacities ranging from 4.5 to 25 kW

• Easy maintenance

• Maximum adaptability to the needs of the installation

MAIN FEATURES

Ductable air conditioning units designed in low profile type fan coil units are equipped with an exchanger comprising copper tubes and aluminium fins. Centrifuge fans driven by three-speed motors.

BHW

Flexible and adaptable applications for water installations.

FAN

CO

ILS

AN

D A

HU

S

AIR CONDITIONING UNITS

MODEL 174 205 358 410

Water temperature cooling capacity 7ºC Speed I-II-III (kW) 3.1 – 4.1 – 4.5 4.4 – 5.0 – 5.3 6.0 – 5.9 – 8.9 7.9 – 9.1 – 10.8

Water temperature heating capacity 50ºC Speed I-II-III (kW) 4.5 – 5.8 – 6.3 6.4 – 7.1 – 7.5 8.6 – 9.7-11.9 11.1 – 12.6 – 14.9

Water temperature heating capacity 70ºC Speed I-II-III (kW) 7.6 – 9.8 – 10.7 10.8 – 12.1- 12.7 14.6 – 16.5 – 20.1 18.8 – 21.4 – 25.2

Total power input kW 0.2 0.3 0.5 0.6

Voltage (50 Hz~) V 230.1 230.1 230.1 230.1

Water flow speed I-II-III l/h 530 – 690 – 760 760 – 850 – 895 1030 – 1180 – 1440 1360 – 1560 – 1850

Airflow speed I-II-III m3/h 600 – 900 – 1050 950 – 1130 – 1220 1100 – 1340 – 1850 1400 – 1700 – 2200

Available pressure speed I-II-III mmca 2 – 2.5 – 3 2.5 – 3 – 4 6 – 7 – 8 6 – 7.5 – 8

Water connection Ø (") 3/4 3/4 3/4 3/4

Dimensions (width x length x height) mm 829x791x219 829x791x258 915x791x285 915x791x315

Net weight Kg 30 34 44 45

MODEL 515 720 724

Water temperature cooling capacity 7ºC Speed I-II-III (kW) 12.2 – 13.9 – 15.3 20.2 25.0

Water temperature heating capacity 50ºC Speed I-II-III (kW) 16.1 – 18.2 – 19.7 26.5 32.7

Water temperature heating capacity 70ºC Speed I-II-III (kW) 27.2 – 30.8 – 33.5 44.8 55.5

Total power input kW 0.6 0.8 1.6

Voltage (50 Hz~) V 230.1 230.1 230.1

Water flow speed I-II-III l/h 2090-2360-2565 3365 4190

Airflow speed I-II-III m3/h 2200-2600-2900 3850 5200

Available pressure speed I-II-III mmca 3 – 4 – 5.5 5 5

Water connection Ø (") 1 1 1/4 1 1/4

Dimensions (width x length x height) mm 1200x826x352 1350x900x412 1350x900x412

Net weight Kg 62 80 80

BHW TECHNICAL SPECIFICATIONS

Page 92: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

91

E05

AIR QUALITYGravimetric filter in return G4

SOUND LEVELDouble thermo-acoustic insulation

UNIT INSTALLATIONPower supply at 60Hzand voltages 230, 208, etc.

Panel with fan contact, therm. relay and circuit breaker

Upgraded motors (depending on models)

Connections opposite side

Grille discharge plenum

Tubular discharge plenum(depending on models)

Thermo-acoustic insulation class M0

Fireproof filter class M0

Hot water heating coil

Additional coil foroperating with 4 tubes

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Filter with bottom outlet

Insertable filter

Main switch

Prepared for assemblyin vertical

MAINTENANCEClogged filter indication

Split filter

REGULATION AND CONTROL

Control for Hydrofan

Alarm indication

Smoke detection

ON/OFF remote

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

FAN

CO

ILS A

ND

AH

US

Page 93: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

92

E06 HORIZONTAL

• Cooling capacities ranging from 18 to 110 kW

• Airflows up to 18,000 m3/h

• Can be integrated in Hydrofan system

• Option of assembly outdoors

MAIN FEATURES

The EHW series are units designed to complement and optimise air-conditioning using hydronic systems. They are equipped with a heat exchanger made of copper tubes and aluminium fins and centrifugal fans driven by motors using pulleys.

MODEL 518 725 830 1036 1042 1250

Water temp. cooling capacity 7ºC kW 18.0 25.0 30.0 36.0 42.0 50.0

Water temp. cooling capacity 50ºC kW 26.7 36.0 32.9 50.0 57.7 69.9

Water temp. cooling capacity 85ºC kW 59.3 79.2 94.2 110.0 127.0 145.0

Water temp. cooling capacity 7ºC R.T. 5.1 7.1 8.5 10.2 11.9 14.2

Water temp. cooling capacity 50ºC R.T. 7.6 10.2 9.4 14.2 16.4 19.9

Water temp. cooling capacity 85ºC R.T. 16.9 22.5 26.8 31.3 36.1 41.2

Total power input kW 0.6 0.8 1.1 0.8 1.1 1.5

Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3

Water flow l/s 2978 4637 5381 6028 6841 7753

Airflow m3/h 3500 4200 5200 5500 6500 8200

Available pressure mmca 8.0 10.5 7.4 10.8 8.0 7.0

Water connections Ø (") 1 1/4 1 1/2 1 1/2 2 2 2

Dimensions (length x width x height) mm 1085x750x580 1130x900x650 1130x900x650 1700x870x650 1700x870x650 1700x870x650

Net weight Kg 108 150 150 214 214 217

EHW TECHNICAL SPECIFICATIONS

EHW

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

FAN

CO

ILS

AN

D A

HU

S

AIR CONDITIONING UNITS

Flexible and adaptable applications for water installations.

Page 94: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

93

E06

ENERGY SAVING

Option of mixing module for free cooling with two or three dampers

EC radial ventilation

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc.

Outdoor installation kit

Upgraded motors

Fireproof filter class M0

Thermo-acoustic insulation class M0

Connections opposite side

Base guides

Horizontal evap. air discharge

Hot water heating coil

Heating coils for use in 4 tube system

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

MAINTENANCE

Clogged filter indication

Split filter

REGULATION AND CONTROL

Control for Hydrofan

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

MODEL 1657 2069 2476 3097 35110

Water temp. cooling capacity 7ºC kW 57.0 69.0 76.0 97.0 110.0

Water temp. cooling capacity 50ºC kW 82.8 100.0 110.0 132.0 155.0

Water temp. cooling capacity 85ºC kW 183.0 220.0 241.0 290.0 342.0

Water temp. cooling capacity 7ºC R.T. 16.2 19.6 21.6 27.6 31.3

Water temp. cooling capacity 50ºC R.T. 23.5 28.4 31.3 37.5 44.1

Water temp. cooling capacity 85ºC R.T. 52.0 62.6 68.5 82.5 97.2

Total power input kW 2.2 3.0 3.0 4.0 4.0

Power supply (50 Hz ~) V 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N 230.3 or 400.3+N

Water flow l/s 9676 11776 12829 15534 17575

Airflow m3/h 9500 11200 12500 14800 18000

Available pressure mmca 11.3 14.5 15.0 18.0 20.5

Water connections Ø (") 2 2 2 2 1/2 2 1/2

Dimensions (length x width x height) mm 2000x937x747 2600x980x752 2600x980x752 2800x1050x915 2800x1050x915

Net weight Kg 291 356 356 452 558

EHW TECHNICAL SPECIFICATIONS

FAN

CO

ILS A

ND

AH

US

Page 95: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

94

E07

• Cooling capacities ranging from 7.6 to 47.6 kW

• Airflows up to 8,200 m3/h

• Can be integrated in Hydrofan system

• Option of assembly outdoors

MAIN FEATURES

The CLW series units are designed to complement and optimise air-conditioning using hydronic systems. They are equipped with a heat exchanger comprising copper tubes and aluminium fins and centrifuge fans with pressure available.

CLW

INDOOR UNITS FOR CONNECTIONTO VERTICAL DUCTS

POSSIBLE AIR SUPPLY / RETURN CONFIGURATIONS standard optional

CLW TECHNICAL SPECIFICATIONS

MODEL 270 412 515 720 824

Water temp. cooling capacity 7ºC kW 7.6 14.0 15.6 18.6 22.4Water temp. heating capacity 50ºC kW 11.7 20.7 23.5 27.9 29.2Water temp. heating capacity 85ºC kW 25.8 45.6 51.8 61.4 64.0Water temp. cooling capacity 7ºC R.T. 2.2 4.0 4.4 5.3 6.4Water temp. heating capacity 50ºC R.T. 3.3 5.9 6.7 7.9 8.3Water temp. heating capacity 85ºC R.T. 7.3 13.0 14.7 17.5 18.2Total power input kW 0.3 0.5 0.6 0.8 0.4Power supply (50 Hz ~) V 230.1 230.1 – 400.3+N 230.3 – 400.3+N 230.3 – 400.3+N 230.3 – 400.3+NWater flow l/h 1,314 2,411 2,684 3,193 3,859Airflow m3/h 1,900 2,801 3,500 4,200 3,500Available pressure Pa 100 50 150 135 100Water connections Ø (") 3/4 1 1 1 1/4 1 1/2Dimensions (length x width x height) mm 697x500x1000 697x500x1000 757x500x1100 1152x600x1200 1152x600x1200Net weight Kg 45 71 94 115 151

AIR CONDITIONING UNITS

FAN

CO

ILS

AN

D A

HU

S

Flexible and adaptable applications for water installations

Page 96: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

95

E07

CLW TECHNICAL SPECIFICATIONS

ENERGY SAVING

Option of mixing box with servo

Fan soft-start

EC radial ventilation

AIR QUALITY

Gravimetric filter in return G4

Opacimetric filter in return class F6 to F9 (combinable with a G4 or Fx+Fy)

SOUND LEVEL

Double thermo-acoustic insulation

UNIT INSTALLATION

Magnetothermics in electrical panel

Power supply at 60Hz and voltages 230, 208, etc. (depending on models)

Outdoor installation kit

Upgraded motors

Fireproof filter class M0

Thermo-acoustic insulation class M0

Connections opposite side

Base guides

Horizontal evap. air discharge

Hot water heating coils

Heating coils for use in 4 tube system

Electric resistance coils for auxiliary electric heating

Anti-corrosion pre-treated coils

Prepared for disassembly

Intake grille

MAINTENANCE

Clogged filter indication

Split filter

REGULATION AND CONTROL

Control for Hydrofan

Alarm indication

Smoke detection

ON/OFF remote

Separate electrical panel

Versions for other climates Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

MODEL 830 1036 1042 1250

Water temp. cooling capacity 7ºC kW 29.5 36.7 41.0 47.6Water temp. heating capacity 50ºC kW 40.1 48.6 55.7 66.9Water temp. heating capacity 85ºC kW 88.0 107.0 122.0 147.0Water temp. cooling capacity 7ºC R.T. 8.4 10.4 11.7 13.5Water temp. heating capacity 50ºC R.T. 11.4 13.8 15.8 19.0Water temp. heating capacity 85ºC R.T. 2.1 3.7 4.2 5.0Total power input kW 1.1 0.8 1.1 1.5Power supply (50 Hz ~) V 230.3 – 400.3+N 230.3 – 400.3+N 230.3 – 400.3+N 230.3 – 400.3+NWater flow l/h 5,079 6,313 7,052 8,191Airflow m3/h 5,200 5,500 6,500 8,200Available pressure Pa 100 85 75 85Water connections Ø (") 1 1/2 2 2 2Dimensions (length x width x height) mm 1152x600x1200 1700x600x1300 1700x600x1300 1700x600x1300Net weight Kg 151 171 171 182

FAN

CO

ILS A

ND

AH

US

Page 97: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

96

E08

AIR HANDLING UNITS

• Airflows ranging from 1000 to 100,000 m3/h

• Modular design

• Indoor or outdoor installation

• Manufactured in aluminium profiles and sandwich panels with several thickness possibilities and insulation

• Multiple configuration possibilities and accessories

• Unit manufactured according to the UNE-EN 1886 standard, regarding thermal and mechanical characteristics of the structure

MAIN FEATURES

The EHWM series of air handling units are specially designed to complement and optimise air conditioning systems in buildings in terms of air handling (ventilation, filtering, humidity management, etc.) They have been designed to offer maximum flexibility in the selection, design and installation.

EHWM

ENERGY SAVING

Crossed flow static recoverer

Rotary recoverer

Inverter fans

Mixing module

AIR QUALITY

Type F and absolute G4 filters,with bag, rigid, etc.

Air quality control

UNIT INSTALLATION

Electric heater

Hot water heating coil

Cold water cooling coil

Expansion coils

Humidification system

Plug-fan fans

Anti-vibration supports

Condensation tray

MAINTENANCE

Inspection door

Safety microswitch on inspectiondoor

Versions for other climates

Versions for other power supplies

As well as these options consult our Commercial Department for any other configuration or function not described as available.

OPTIONS AVAILABLE

EHWM CLASSIFICATION ACCORDING TO STANDARD UNE-EN 1886

CHARACTERISTICS CLASS

Mechanical resistance D1Pitch (negative/positive pressure) L1

Derivation of the filters F9Transmittance T2Thermal bridge TB1/TB2

FAN

CO

ILS

AN

D A

HU

S

Flexible and adaptable applications for water installations.

Page 98: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

97

FFor AIR-TO-AIR and WATER-TO-AIR self-contained unit range Page 98

For INVERTER, AIR-TO-AIR self-contained unit range Page 99

For ROOF TOP AND WATER-TO-AIR SELF-CONTAINED unit range Page 99

For ROOF TOP AND AIR-TO-AIR SELF-CONTAINED unit range Page 99

For Krono Series water chiller units Page 100

Centralised Management System and BMS Page 101

Supervision System (BMS) Plant Visor Page 103

Hydrofan System Page 105

REGULATION AND CONTROL

Page 99: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

98

F

For AIR-TO-AIR and WATER-TO-AIRself-contained unit range

REGULATIONAND CONTROL

RTR 7035 THERMOSTATOperation at 220 V at 24 V

One cool stage and one heat stage

ON/OFF selector

Temperature control dial

Ventilation selection

COOL / HEAT selection

Wall mounted

T8376B THERMOSTAT

SUPER-SI CONTROL

ETN

DSX@

Analogue thermostat

Operation at 24 V

One cool stage and one heat stage

ON/OFF selector

Digital thermostat with LCD screen

Operation at 24 V

Hot / cold / automatic selector

Fan speed selector

For units with1 or 2 compressors

Digital thermostat with LCD screen

Operation at 220 V

Hot /cold / automatic selector

Fan speed selector

Option of scheduling function (programmable ETN)

Digital thermostatwith LCD screen

Operation at 24 V

Hot /cold / automatic selector

Fan speed selector

For machineswith 1 or 2 compressors

Temperature control dial

Ventilation selection

COOL / HEAT selection

Wall mounted

Cooling only and heat pump

1 or 2 resistance stages

Contact window/economy function

Indoor/outdoor sensor (remote)

Temperature regulation range: 10ºC to 30ºC Includes all the control and protection functions of the unit

For units with heat pump or only cooling with option of one electric heater stage

Wall mounted

Cooling only and heat pump

1 or 2 resistance stages

Scheduling function

Indoor/outdoor sensor (remote)

Integrated Modbus protocol

communications output

RE

GU

LAT

ION

AN

D C

ON

TR

OL

Page 100: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

99

FFor INVERTER, AIR-TO-AIRself-contained range units

For SELF-CONTAINED ROOF TOP AND WATER-TO-AIRunit range

For SELF-CONTAINED ROOF TOP AND WATER-TO-AIRunit range

ARIA

pGD (with PCOC, PCOC3 control cards)

Thermostat comprising a user interface terminal installed in the environment, and a input and output board located on the outdoor unit (electric panel). For AIR-TO-AIR or WATER-TO-AIR units

For units with 1 or 2 compressors

Cooling only and heat pump

2 heat stages

Control sensor configurable in environment or in return (remote)

Thermostat comprising a user interface terminal installed in the environment, and a input and output board (PCOC, PCO3) located on the outdoor unit (electric panel). Only for AIR-TO-AIR units

For unitswith 1 or 2 compressors

Cooling only and heat pump

Control of 2 or 3 electric resistance stages, heat valve and gas burner module

Parameterisable thermostat, with 3 access levels: User, Maintenance, Manufacturer

Scheduling function

(model: PROGRAMMABLE ARIA)

Option of interconnection units in network: model ARIA pLAN (refer to Centralised management systems section)

Output with Modbus, BackNet, Lonworks communication protocols, via supernode gateway and the card of the used protocol

Option of adapting and modifying the internal software to meet specific customer needs and functions

Option of interconnecting units in a network (refer to Centralised Management Systemssection)

Several options available: clock card for function scheduling, cards available for Modbus, BacNet, Lonworks, TCP-IP... communication protocols.

RE

GU

LAT

ION

AN

D C

ON

TR

OL

th TUNEThermostat comprising a user interface terminal installed in the environment, and a input and output board (uPC) located on the outdoor unit (electric panel). For INVERTER R410A, AIR-TO-AIR units

For unitswith 1 inverter compressor

Cooling only and heat pump

Power supply at 220 V

Selection of 3 speeds of the indoor fan or automatic

1 electric resistance stage (only active in defrost) Control sensor in return (remote)

Parameterisable thermostat, with 3 access levels: User, Maintenance, Manufacturer

Option of Modbus communications protocol using RS-485 card

Page 101: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

100

FFOR WATER CHILLER UNITS

MICROCHILLER 2Thermostat typically used for AIR-TO-WATER or WATER-TO-WATER water chiller units. Made up of only one set that is used as a user interface and electronic board

For unitswith 1 or 2 compressors

Cooling only and heat pump

Management of the recirculation pump and inertia module

Scheduling function

Parameterisable thermostat, with 3 access levels: User, Maintenance, Manufacturer

Option of interconnecting units in a network (refer to Centralised Management Systems section)

Option of output Modbus communication protocol via communication card

DN33Thermostat typically used for AIR-TO-WATER or WATER-TO-WATER water chiller units. Made up of only one set that is used as a user interface and electronic board.

For unitswith up to 4 compressors.

Cooling onlyand heat pump.

Scheduling function

Management of the heatpump and inertia module.

Parameterisable thermostat, with 3 access levels: User, Maintenance, Manufacturer

Option of output Modbus communication protocol via communication card

MCX08Parameterisable thermostat typically used for R410A refrigerant AIR-TO-WATER or WATER-TO-WATER water chiller units. Made up of only one set that is used as a user interface and electronic board

For unitsof up to 4 compressors

Cooling only and heat pump

Management of the recirculation pump and inertia module

Scheduling function

Parameterisable thermostat, with 3 access levels: User, Maintenance, Manufacturer

Option of interconnecting units in a network (refer to Centralised Management Systems section)

Option of output Modbus communication protocol via communication card

RE

GU

LAT

ION

AN

D C

ON

TR

OL

Page 102: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

101

FCENTRALISED MANAGEMENT SYSTEM AND BMS Centralised control for units with Aria pLAN thermostat

Centralised control for units with PGD thermostat and PCOC, PCO3 boardsConnection of several units using the pLAN network belonging to the PCOC, PCO3 board. Each of the machines connected in a network can be accessed from a single PGD thermostat. Maximum of 15 connection units.

Network up to 15 unitsCentralised management for an ARIA pLAN unit network, via a PGD control

Network of 15-40 unitsCentralised management for an ARIA pLAN unit network, via a PGD control

RE

GU

LAT

ION

AN

D C

ON

TR

OL

“ARIA” CONTROLLER “ARIA” CONTROLLER “ARIA” CONTROLLER

Connection to BMS with the following integrationlanguages: “Modbus” “Lonworks” “BacNet”.Please ask for details if you require other integration languages.

“ARIA” CONTROLLER “ARIA” CONTROLLER “ARIA” CONTROLLER

SUPERNODE

Page 103: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

102

1 2 3

F

Centralised control for units with MICROCHILLER 2 thermostatOutput towards BMS supervision system via FCSER cards.

BMS connection using the following integration languages: Modbus. Please ask for details if you require other integration languages.Maximum number of connected units varies according to the integration language, please ask for details.

Centralised control for units with DN33 thermostatOutput towards BMS supervision system using specific RS-485 card for DN33.

Connection of several units with PCOC, PCO3 cards via RS-485 cards towards a supervision system.

BMS connection using the following integration languages:Modbus – Lonworks – BacNet. Please ask for details if you require other integration languages.

Modbus. Please ask for details if you require other integration languages.Maximum number of connected units varies according to the integration language, please ask for details.

RE

GU

LAT

ION

AN

D C

ON

TR

OL

Page 104: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

103

Pl@ntVisor

F

Main features:

Monitoring functions with visual and graphic elements

User management for access control and operations registration

Management of configurable reports

Alarm management

Local and remote connectivity

Scheduling function

Energy saving management

Option of screen personalisation, emulating installation (SCADA)

Activity planning and controls for instruments or groups of instruments

SUPERVISION SYSTEM (BMS) PLANT VISOR Carel supervision and monitoring system designed to control facilities.All thermostats with MODBUS output can be integrated via RS-485.

Personalised screen for Roof Top, basic control of the unit: allows carrying out basic operations: ON-OFF, cold/heat selector, change temperature setpoints and display the status of the main components.

Facility map screen (example):a personalisation of the facility can be carried out.

Maximum number of connected units varies according to the Plant Visor model.

RE

GU

LAT

ION

AN

D C

ON

TR

OL

(CVSTD00000) (IR32XXXXX)Unit 15

(PJ32XXXXX)Unit 13

(IRDRXXXXX)Unit 14

(PCO2000XX0)Unit 12 (MTCDXXXXXX)

Unit 1

Pl@ntVisor(free)

Pl@nt Visor

Page 105: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

104

F

Screen with a complete alarms list (access according to user level): allows displaying the alarms and resetting them.

Report management screen (access according to user level): allows configuring and making reports, according to date intervals and variables selected.

Roof Top unit detail screen: allows displaying all the variables and changing all the parameters via the Plant Visor.

Screen with a complete parameter list (access according to user level): allows reading/changing the values and saving them (backup).

RE

GU

LAT

ION

AN

D C

ON

TR

OL

Page 106: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

105

FHYDROFAN SYSTEMSystem designed to control water installations in a centralised, simple and efficient way. Made up of a set of components, including a touch screen, to control installations with water chiller units, fan coils and ATUs.

RE

GU

LAT

ION

AN

D C

ON

TR

OL

SYSTEM COMPONENTS

Cards

Fcc base card

4 relay card

Card 2 x (0-10 V) + 2 relays

RS-485 serial card

Thermostat

AMBIENT AQUA

PGD TOUCH touch screen

The touch screen carries out the centralised control function. This offers the possibility of using a user and password access to control the elements in the facility.

Screen with all the network's elements (14 FCC, 1 AHU and 1 cooler appear in this installation).

We can access each fan coil, to turn it ON-OFF, modify setpoint, select automatic or manual low, medium or highspeed and see the cold or heat status.

AHU detail screen, to turn to ON-OFF, modify setpoint, see valve opening and cold or heat status.

Cooler detail screen, to turn to ON-OFF, select cold or heat, see discharge and return temperature, and if the cooler has an alarm.

This screen can be used to configure a timetable to start and stop all the elements.

The touch screen can govern installations of up to 30 fan coils with 1 cooler. For installations with more elements consult possible configurations.

Page 107: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

106

NOTES

Page 108: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

107

NOTES

Page 109: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

108

NOTES

Page 110: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

109

NOTES

Page 111: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

110

NOTES

Page 112: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

111

NOTES

Page 113: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

112

NOTES

Page 114: General Catalogue 2013-2014 - Hitecsa Cool Air...FPW, wall mounted fan coil Page 86 BSW, fan coil installation high pressure ducts available Page 87 BHW, ductable fan-coil Page 90

HIPLUS AIREACONDICIONADO S.L.

Masia Torrents, 2Tel. +34 938 934 912Fax +34 938 939 61508800 Vilanova i la GeltrúBarcelona, Spain

www.hitecsa.com