GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter...

44
GENERAL CATALCG GENERAL CATALOG CF Meter& EC Meter Wastewater & Sewage Pumps Refractometers TDS Meters PH Meters ORP Meters Tachometers Thermometers Conductivity Meters

Transcript of GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter...

Page 1: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

GENERAL CATALCGGENERAL CATALOG

CF Meter& EC Meter

Wastewater & Sewage Pumps

Refractometers

TDS Meters

PH Meters

ORP Meters

Tachometers

Thermometers

Conductivity Meters

Page 2: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

pH Meters KL-009(I) Pocket-sized pH Meter

KL-009(II) High Accuracy Pen-type pH Meter

KL-009(III) High Accuracy Pen-type pH Meter

KL-03(I) High Accuracy Pen-type pH Meter

KL-03(II) Waterproof Pen-type pH Meter

KL-03(III) Waterproof Pen-type pH Meter

KL-010 Folding Three In One pH Tester

KL-008 High Accuracy Portable pH Meter

KL-013 High Accuracy Portable pH Meter

KL-016 Bench-top pH Meter

KL-025 Mini pH Meter

KL-1385 Waterproof Conductivity Meter

KL-203 Digital pH/ORP Controller

Online pH Instrument KL-018 Industrial On-line pH Controller

KL-100 Digital pH Controller

KL-201 Digital pH Controller

Online ORP Instrument KL-019 Industrial On-line ORP Controller

KL-200 Digital ORP Controller

KL-206 Digital ORP Controller

Online Conductivity Instrument KL-208 Digital Conductivity Controller

Tachometers KL-005 /006 Tachometer

KL-007 Many Functions Tachometer

Thermometers KL-9806 Digital Mini Thermometer

KL-9816 Folding Thermometer

KL-9826/9836 Digital Hygro Thermometer

Refractometers Hand Held Refractometers

Wastewater & Sewage Pumps KL-51 Water Pump

CONTENTS

Reference List

(P27)

(P31)

(P34)

(P35)

(P37)

(P40)

(P41)

Conductivity MetersKL-138 Electric Conductivity Meter

KL-1371/1372 Pen-type EC Meter

KL-1382 Conductivity Tester

KL-1383 Conductivity Tester

ORP MetersKL-169 ORP/Redox Tester

TDS Meters KL-139 TDS Tester

KL-1393 TDS Tester

(P13)

(P20)

(P24)

CF MeterKL-1361/1362 Pen-type CF Meter

(P26)

(P1)

Page 3: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Reliable and stable Easy operation

Low cost Easy to carry

KL-009(I)Pocket-sized pH Meter

KL-009(I) KL-009(I)A

0.0~14.0pH

0.2pH

0.1pH(at 20 )

0.1pH

3 1.5V(AG13)

0.1pH

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

KL-009(I)B

Power Supply

Dimensions

Weight

Plug BNC Fixed Electrode

3142 29 15(mm )

51g 70g

Model

0.2pH

0.1pH(at 20 )

TECHNICAL SPECIFICATION

4 1.5V(AG13) 4 1.5V(AG13)

Automatic Temperature

Compensation

0 ~50

KL-009(I)A

KL-009(I)

KL-009(I)B

Page 4: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Easy to read LCD

Reliable and stable

Automatic Temperature Compensation

High Accuracy with 0.01 pH resolution

KL-009(II)

TECHNICAL SPECIFICATION

KL-009(II) KL-009(II)A 0.00~14.00pH

0.01pH

4 1.5V (A G1 3)

0.1pH

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Dimensions

Weight

Plug Fixed Electrode

3170 36 23(mm )

85g

Model

0 ~50

BNC

105g

KL-009(II)

Automatic Temperature

Compensation

KL-009(II)A

High Accuracy Pen-type pH Meter

Page 5: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-009(III)

TECHNICAL SPECIFICATION

4 1.5V (A G 13)

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Dimensions

Weight

3170 36 23(mm )

91g

Model

0 ~50

0.00~14.00PH 0 ~55

KL-009(III)

0.01PH 0.1

0.1PH 1

Easy-to-read Custom Dual-level LCD

On-the-spot measurement

Automatic Temperature Compensation

Stability Indicator

Automatic Temperature

Compensation

High Accuracy Pen-type pH Meter

Page 6: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Lightweight and compact

Quick accurate readings

Membrane switching

Long Battery Life

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Dimensions

Weight 46g

Model

0 ~50

0.00~14.00PH

0.01PH

0.1PH

2 3V CR2032 Battery

3150 27 20 mm

KL-03(I)

Automatic Temperature

Compensation

KL-03(I)High Accuracy Pen-type pH Meter

Page 7: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Model

0 ~50

0.00~14.00PH

0.01PH

0.1PH

4 1.5V(AG13 )

Calibration 1 point

Dimensions

Weight 63g

3165 26 26 mm

Waterproof

Replaceable Electrode Design

Compact, handy

Long Battery Life

KL-03(II)Waterproof Pen-type pH Meter

KL-03(II)

Automatic Temperature

Compensation

Page 8: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Model

0 ~50

0.00~14.00PH

0.01PH

0.1PH

4 1.5V(AG13 )

Calibration 1 point

Dimensions

Weight 70g

3120 26 26 mm

Waterproof

Replaceable Electrode Design

Compact, handy

Long Battery Life

Pen-type pH Meter

KL-03(II)A

Automatic Temperature

Compensation

KL-03(II)A

Page 9: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Waterproof Pen-type pH Meter

KL-03(III)

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Model

0 ~50

0.00~14.00PH

0.01PH

0.1PH

4 1.5V(AG13 )

Dimensions 3188 35 35 mm

Large and easy-to-read LCD

Replaceable pH electrode

Waterproof design

Data hold

KL-03(III)

Automatic Temperature

Compensation

PH

PH-03(III)

HOLD

ONOFF

Page 10: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION KL-010Folding Three In One pH Tester

Folding design

Large LCD

Easy operation

Simultaneous display of pH, Temperature and Humidity

Measuring range

0.00~14.00PH

5 ~50

10% 99%RH

Resolution

PH

0.01PH

0.1

1%RH

Accuracy

0.1PH

1

5%RH

¡ æ

RH

PH

¡ æ

RH

PH

¡ æ

RH

0 ~50

Operating

Temperature

Power Supply

0 ~50

4 1.5V(A G13)

Dimensions

Weight 95g

3156 55 23 mm

Automatic Temperature

Compensation

Model KL-010

Page 11: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Mini PH Meter

KL-025

TECHNICAL SPECIFICATION

Measuring range

Accuracy

Resolution

Operating

Temperature

Power Supply

Model

0 ~50

0.00~14.00PH

KL-025

0.01PH

0.1PH

4 1.5V(AG13)

Dimensions

Weight 62g

360 55 23 mm

Page 12: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

High Accuracy Portable PH Meter

KL-008It is applicable to determine pH value of water

solution in departments of medical treatment,

environment protection,scientific research, co-

llege and mechanical plant etc.

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Resolution

Operating

Temperature 0 ~50

0.00~14.00PH

0.01PH

0.1PH

Power Supply

Dimensions

Weight 260g

4x1.5V(DC)alkalinity battery

3200x60x24.5 mm

Automatic Temperature

Compensation

Model KL-008

Page 13: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Measuring range

0.00~14.00PH

0~100

PH

¡ æ

Temp

TECHNICAL SPECIFICATION

Power Supply 9V Battery

Dimensions

Weight 290g

3180 83 46 mm

0.01pH

1mV

0.1

Resolution ¡ æ

PH

Temp

0.1% F S 1digit

0.4

Accuracy

0.01pH

¡ æ

PH

Temp

Display 4-digital LCD

Environment

Temperature:0 ~50

Humidity: 95%

Input

Impedance1210

0~ 1999mV

KL-013High Accuracy Portable pH Meter

Splashproof membrane switching - push - button calibration

Measures pH, mV, and temperature (Centigrade)

Automatic temperature compensation

9-Volt Battery Operation

Vm

Vm

Vm

Model KL-013

Page 14: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

V

Vm

Vm

Measuring range

0.00~14.00PH

0~100

PH

Temp

Power Supply

TECHNICAL SPECIFICATION

AC110V or AC220V 50/60 Hz

Dimensions

Weight 660g

3240 185 100 mm

0.01pH

1mV

0.1

Resolution

PH

Temp

0.1% F S 1digit

0.4

0.01pH

Accuracy

PH

Temp

Display 4-digital LCD

Environment

Temperature:0 ~50

Humidity: 95%

1210

0~ 1999mV

KL-016 Bench-top pH Meter

Interchangeable probes

Ergonomic design

Automatic Temperature Compensation

Impedance

Input

Model KL-016

m

Page 15: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-138Electric Conductivity Meter

Light weight and pocket sized

Easy operation

Reliable and stable

Easy to carry

TECHNICAL SPECIFICATION

Model KL-138

Display 3-digital LCD

0 ~50

51g

0 ~50

.2%F S

10 us/cm

10~1990us/cm

4x1.5V(A G13)

3142 29 15 mm

Measuring range

Accuracy

Operating

Temperature

Power Supply

Dimensions

Weight

Resolution

Automatic Temperature

Compensation

Page 16: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-1382Conductivity Tester

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight 46g

Model

.2%F S

Resolution 1 us/cm

0~1999us/cm

Display 4-digital LCD

KL-1382

Environment Humidity: 95%

Automatic Temperature

Compensation

2 3V CR2032 Battery

3150 27 20 mm

Page 17: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight 63g

Model

.2%F S

Resolution 1 us/cm

0~1999us/cm

Display 4-digital LCD

3165 26 26 mm

KL-1382A

Environment Humidity: 95%

KL-1382B

4 1.5V A G13

360X55X23 mm

60g

Conductivity TesterKL-1382A/B

Automatic Temperature

Compensation

KL-1382B

KL-1382A

Page 18: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-1383Conductivity Tester

TECHNICAL SPECIFICATION

Measuring range

Accuracy

Power Supply

Dimensions

Weight

Model

Resolution

Display

Environment

0~19.99ms/cm

0 ~50

46g

.2%F S

0.01ms/cm

4-digital LCD

3150 27 20 mm

KL-1383

2 3V CR2032 Battery

Humidity: 95%

Automatic Temperature

Compensation

Page 19: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight

Automatic Temperature

Compensation

63g

Model

.2%F S

Resolution 0.01ms/cm

0~19.99ms/cm

Display 4-digital LCD

3165 26 26 mm

KL-1383A

Environment Humidity: 95%

KL-1383B

4 1.5V A G13

360X55X23 mm

60g

KL-1383A/BConductivity Tester

KL-1383A

KL-1383B

Page 20: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Pen-type EC Meter

KL-1371/1372

KL-1371 KL-1372

Measuring range

Resolution

Accuracy

Operating Temperature

0.1EC

2%F.S

0 ~50

Power Supply

Dimensions

Weight

4x1.5V (A G13)

3142x29x15(mm)

51g

2x3V (CR 2032B attery)

3150x27x20(mm)

46g

0.01EC

0 ~50 Automatic

Temperature Compensation

KL-1371 KL-1372

0~19.9EC 0~19.99EC

TECHNICAL SPECIFICATION

Model

Page 21: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

0.00~19.99EC

0.0~199CF

10~19990ppm

2%F.S

0.01EC

0.1CF

10ppm

KL-1385 EC/CF/TDS Waterproof Conductivity Meter

Measuring range

Resolution

EC

Accuracy

¡ æ

TDS

TECHNICAL SPECIFICATION

0 ~50

Operating

Temperature

Power Supply

0 ~50

4 1.5V(A G13)

Dimensions 3185 38 38 mm

CF

EC

¡ æ

TDS

CF

Large and easy-to-read LCD

Waterproof design to withstand wet environment

Measures 3 parameters including EC,CF,TDS using one electrode

Hold Function -- Saves measurements for convenient reading and recording

Automatic Temperature

Compensation

Model KL-1385

P Pm

EC-1385

HOLD

MODE

ON

OFF

Page 22: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TDS TesterKL-139

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight 46g

Model

.2%F S

Resolution

Display 4-digital LCD

3150 27 20 mm

2 3V CR2032 Battery

Environment Humidity: 95%

0~1999 PPm(mg/L)

1 PPm(mg/L)

KL-139

Automatic Temperature

Compensation

Page 23: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TDS TesterKL-139A/B

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight 63g

Model

.2%F S

Resolution

Display 4-digital LCD

3165 26 26 mm

KL-139A

Environment Humidity 95%

KL-139B

4 1.5V A G13

360X55X23 mm

60g

0~1999 PPm(mg/L)

1 PPm(mg/L)

Automatic Temperature

Compensation

KL-139A

KL-139B

Page 24: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TDS TesterKL-1393TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight 46g

Model

.2%F S

Resolution

Display 4-digital LCD

3150 27 20 mm

2 3V CR2032 Battery

Environment Humidity 95%

0~19.99 ppt

KL-1393

0.01 ppt

Automatic Temperature

Compensation

Page 25: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TDS TesterKL-1393A/B

TECHNICAL SPECIFICATION

0 ~50

Measuring range

Accuracy

Power Supply

Dimensions

Weight 63g

Model

.2%F S

Resolution

Display 4-digital LCD

3165 26 26mm

KL-1393A

Environment Humidity 95%

KL-1393B

4 1.5V A G13

360X55X23 mm

60g

0~19.99ppt

0.01ppt

Automatic Temperature

Compensation

KL-1393A

KL-1393B

Page 26: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

ORP/REDOX TESTER

KL-169TECHNICAL SPECIFICATION

Measuring range

Accuracy 5mv

Resolution

Display 4-digital LCD

0~ 1999 mv

1mv

Model

Dimensions

Weight 63g

3165 26 26 mm

Power Supply

KL-169-A

46g

3157 27 20 mm

2 3V CR2032 Battery

KL-169-B

91g

3170 36 23 mm

KL-169-C

KL-169-AKL-169-C KL-169-B

4 1.5V A G13 4 1.5V A G13

Page 27: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-169-D KL-169-E

HOLD

ONOFF

ORP-169E

Model

Dimensions

Weight 85g

Power Supply

KL-169-D

118g

3188 35 35 mm

KL-169-E

62g

360 55 23 mm

KL-169-F4 1.5V A G13

3170 36 23 mm

4 1.5V A G13 4 1.5V A G13

KL-169-F

Page 28: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Measuring

range

Resolution

Accuracy

Operating

Temperature

Power Supply

Calibration

Dimensions

Weight

KL-1361

0~100CF

2%F.S

0 ~ 50

3142x29x15(mm)

51g

1 point

3150x27x20(mm)

46g

KL-1362

KL-136

(AG13 ) 2x3V

(C R2032 B attery)

4x1.5V

1CF

KL-1362 KL-1361

TECHNICAL SPECIFICATION

Model

Pen-type CF Meter

Page 29: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Front panel LED indicate

High Input Impedance

Isolated 4 to 20 mA recorder output.

0.01 pH accuracy with unbeatable performance.

Warning

Accuracy

TECHNICAL SPECIFICATION

0 ~100

Measuring range

Accuracy

Power Supply

Dimensions

Weight 950g

Model

Resolution

396 96 160 mm

Environment Temperature:0~50Humidity 95%

Stability 0.02pH/24h

0.02pH

0.01pH

0.00~14.00pH

0.02pH

Output Current 4~20mA

220V 10%50Hz 2%

Calibration Single-point or double-point

Input Impedance

1210

4-digital LEDDisplay

KL-018

Automatic Temperature

Compensation

KL-018Industrial Online pH Controller

Page 30: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-100Digital PH Controller

4-digit LED displays

High Input Impedance

Front panel LED indicate HIGH/LOW alarm status

User friendly menus are tactile keypad for easy programming

TECHNICAL SPECIFICATION

Measuring range

Accuracy

Power Supply

Weight 550g

Model

Resolution

EnvironmentTemperature:0~50

Humidity 95%

0.02pH

0.01pH

0.00~14.00pH

5A/240VAC

AC110V or AC220V 10%50Hz

Input Impedance

1210

4-digital LEDDisplay

KL-100

Set Range 3.50~10.50PH

Relay Contact

Calibration Double-point

Dimensions 3108 210 48 mm

Page 31: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Applications:

Aquariums, Aquacultures, Beverage, Fish Hatcheries, Food Processing,

Photography, Laboratory, Paper Industry, Swimming Pool, Plating Industry

Digital PH Controller

KL-201

Wall-Mount & Hand-Held Type, Professional QualityTECHNICAL SPECIFICATION

Measuring range

Accuracy

Power Supply

Dimensions

Model

Resolution

Environment Temperature:0~50Humidity 95%

0.01pH

0.00~14.00pH

5A/240VAC

AC110V or AC220V 10%50Hz

Input Impedance

1210

4-digital LEDDisplay

KL-201

Set Range 3.50~10.50PH

Relay Contact

Calibration

(0.1%+2 digits) after calibration

External pH4 (Slope), pH7 (Cal)

150 x 85 x 40 mm

(5.9x3.4x1.6 inch)

Page 32: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Digital pH/ORP ControllerWall-Mount & Hand-Held Type, Professional Quality

KL-203TECHNICAL SPECIFICATION

Measuring range

Power Supply

Dimensions

Model

Resolution

Environment Temperature:0~50Humidity 95%

0.00~14.00pH

5A/240VAC

AC110V or AC220V 10%50Hz

Input Impedance

1210

4-digital LEDDisplay

KL-203

Set Range 3.50~10.50PH

Relay Contact

Calibration External pH4 (Slope), pH7 (Cal)

150 x 85 x 40 mm

(5.9x3.4x1.6 inch)

0~ 1999mV

PH

ORP

Accuracy PH

ORP

PH

ORP

(0.1%+2 digits)

after calibration

0.01 pH

1 mV

Applications :

Aquariums, Aquacultures, Beverage, Fish Hatcheries,

Food Processing, Photography, Laboratory, Paper Industry,

Swimming Pool, Plating Industry, Quality control, Water Conditioning,

School & colleges.

Page 33: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-019Industrial on-line ORP Controller

Relay contact

TECHNICAL SPECIFICATION

Measuring range

Accuracy

Power Supply

Dimensions

Weight 950g

Model

Resolution

396 96 160 mm

Environment Temperature:0~50Humidity 95%

(0.1%+2 digits) after calibration

1 mV

0~ 1999mV

two 220V5A

Output current 4~20mA(max charge:50 )

110V or 220V 10% 50/60HZ 5%

Input Impedance

1210

4-digital LEDDisplay

KL-019

Page 34: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

Power Supply

Model

Resolution

Environment Temperature:0~50Humidity 95%

AC220V/5A

110V or 220V 10% 50Hz 2%

Input Impedance

1210

4-digital LEDDisplay

KL-200

Set Range -500~500 mV

Relay Contact

Accuracy

1 mV

Measuring range 0~ 1999mV

Dimensions 108x210x48( 3mm )

Weight 550g

Digital ORP Controller

KL-200

0.1%+2 digits

Page 35: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-206Digital ORP Controller

Wall-Mount & Hand-Held Type, Professional Quality

Characteristics:

TECHNICAL SPECIFICATION

Power Supply

Dimensions

Model

Resolution

Environment Temperature:0~50Humidity 95%

5A/240VAC

110V or 220V 50/60 Hz

Input Impedance

1210

4-digital LEDDisplay

KL-206

Set Range -500~500 mV

Relay Contact

3150 x 85 x 40 (mm )

(5.9x3.4x1.6 inch)

Accuracy (0.1%+2 digits)

after calibration

1 mV

Measuring range 0~ 1999mV

Applications : Aquariums, Aquacultures, Beverage, Fish Hatcheries,

Food Processing, Photography, Laboratory, Paper Industry,

Swimming Pool, Plating Industry, Quality control, Water Conditioning,

School & colleges.

Page 36: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

Power Supply

Model

Resolution

Environment Temperature:0~50Humidity 95%

5A/240 VAC

110V or 220V 50/60 Hz

Input Impedance

1210

4-digital LEDDisplay

KL-208

Set Range 0~1000 uS / 0~ 100.0 mS

Relay Contact

1us/ 0.1 mS

Measuring range 0~1999us/0~199.9 mS

Dimensions

3150x85x40(mm )

(5.9x3.4x1.6 inch)

(1.5%+2 digits) after calibrationAccuracy

Digital Conductivity ControllerWall-Mount & Hand-Held Type, Professional Quality

KL-208

Applications :

Aquariums, Aquacultures, Beverage, Fish Hatcheries,

Food Processing, Photography, Laboratory, Paper Industry,

Swimming Pool, Plating Industry, Quality control, Water Conditioning,

School & colleges.

Page 37: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Tachometer

KL-005/006

TECHNICAL SPECIFICATION

Battery

Model

Mtore time

Measuring distance 50 400mm

4 1. 5V DC alkalinity battery

Operating

Temperature0 ~50

4-digital LEDDisplay

KL-005

Adoption time 1s(automation)

no limit

Measuring range 60 9999r/min

Dimensions 378 38 180(mm )

-42 10 N 1digitAccuracy

KL-006

5-digital LCD

20 50000r/min

Page 38: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Many Functions Tachometer

KL-007

TECHNICAL SPECIFICATION

Battery

Model

Store time

Measuring distance

50 400mm

4 1. 5V DC alkalinity battery

Operating

Temperature0 ~50

5-digital LCD Display

KL-007

Adoption time 1s(automation)

no limit

Measuring range 6~99999r/min 2r/min

Dimensions 3200 60 24.5(mm )

-42 10 N 1digitAccuracy

Frequncy 0.5~999.99Hz 0.02Hz

Enumerate 1~99999

Part-time 1S~10h 0.01%

Page 39: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

TECHNICAL SPECIFICATION

Model KL-9806

Measuring range

Dimensions 360 55 23(mm )

0.1

1

-50 ~70

Resolution

Accuracy

Power Supply 1.5V (A G13)

Weight 43g

KL-9806Digital Mini Thermometer

LCD display

In / out temperature measurement

Super-thinness design

Page 40: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-9816Folding Thermometer

TECHNICAL SPECIFICATION

Model KL-9816

Measuring range

Dimensions 3155 48 22(mm )

-50 ~125

Accuracy

Power Supply

0 0-58 F~257 F

00.1 / FResolution

01 or 2 F

at 0.0 ~8002 or 4 F

at -50 ~0.0

80 ~125

Frequency

1.5V (A G13)

2 or 10 second

Large LCD

Folding design

Memory records

Stainless steel probe

Page 41: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

KL-9826/9836Digital Hygro Thermometer

Power Supply

-5 ~500 023 F~122 F

Weight 128g

TECHNICAL SPECIFICATION

Model KL-9826

Measuring

range

Dimensions 396 110 22(mm)

Accuracy

1.5V

0.1(2 F)Resolution

1

Display

RH 10%RH-99%RH

RH

RH

1%RH

5%RH

Dual-level LCD

115g

KL-9836

3140 76 16(mm)

1.5V

Maximum and minimum temperature and humidity memory function

with optional daily reset function.

/ F range selectable at any time

Time display

Threel-level LCD

9826 9836

Page 42: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

Hand held RefractometersRefractometers are precision optical instruments designed to measure the concentration or mixture ratio of water soluble. Easy to use, just place a few drops of juice on the prism glass and hold up to the l ight. And ATC refractometers automatically compensate temperature changes so the user can

Brix Industrial Fluid

Salinity

Clinical Protein(Urine)

Antifreeze/Battery/Cleaning/Fluid

Alcohol Wine

Honey Tester

Contact Lens Tester

Grape Tester

Soybean Milk Tester

Gem TesteroOE Tester

The Hand Held Refractometers provide with a direct reading of the Scales, and have been p r o f e s s i o n a l l y d e s i g n e d f o r t e s t i n g o f concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Salt water, Brine, Cleaning fluid, battery fluid, Antifreeze and Industrial fluids etc. just drop a few drops of a juice and read.

Page 43: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

WASTEWATER & SEWAGE PUMPS

Sump pump, made of stainless steel plate and

fibre-reinforced plastic, resistant to corrosion

Submersible Vortex Pump

KL-51 Water Pump

TECHNICAL SPECIFICATION

Model KL-51Discharge Bore

Motor Output

Phase

Revolution

Starting Method

Max Head

Max Capacity

Impellent Passage

Standard Cable Length

Weight

50 mm

0.15 kW

Single

3000/3600 50Hz/60Hz/min

Capacitor Run

5.2/5.5 50Hz/60Hz /m30.22m /min

35 mm

3m

4.8 kg

Page 44: GENERAL CATALOGALCG - kelilong.comkelilong.com/img/Catalog.pdf · (P13) (P20) (P24) CF Meter KL-1361/1362 Pen-type CF Meter (P26) (P1) Reliable and stable Easy operation Low cost

ADD NO.60 Xing Ye M Road Fuan Fujian China

TEL +86-593-6550588 6366980 6551718 6681718

FAX +86-593-6366980 6551718 6550158

Http://www.kelilong.com E-mail: [email protected]

iddle

KELILONG ELECTRON CO.,LTD

GENERAL CATALCGGENERAL CATALOG