Medium & High Voltage Cables Units Item1
Product identification and Features
Cable code 1310122
Cable type HEPRZ1Standard UNE-HD 620-9E
Standard IBERDROLA 56.43.01
Nominal voltage kV 12/20
N of cores x C.S.A. 1 x400 H16
Construction and Dimensions
Conductor material Al
Shape Circular
Class / Standard 2 / CEI-60228
Nominal diameter mm 23,00
Conductor screen material Extruded semi-conducting layer
Nominal radial thickness mm 0,5
Insulation material HEPR
Nominal radial thickness / Minimum at any point mm 4,3 / --
Diameter over insulation mm 32,6
Insulation screen material (non metallic) Extruded semi-conducting layer
Nominal radial thickness mm 0,5
Insulation screen (metallic) CWS
N of wires x Diameter N x mm 60x0,583
C.S.A. (Cu wires) mm 16
Outer sheath material LLDPE
Nominal radial thickness / Minimum at any point mm 3,0 / --
Nominal overall diameter mm 42,0
Nominal total weight kg/km 2130
Minimum bending radius (after installation) mm 650
Electrical Data
Maximum conductor DC resistance, at 20 C Ohm/km 0,0778
Star reactance per phase, at 50 Hz Ohm/km 0,098
Capacitance per phase F/km 0,472
Charging current per phase, at Uo, 50 Hz A/km 1,778Maximum permanent current rating (*) A 670 (1) / 471 (2)
Maximum conductor temperature in service / in short-circuit C 105 / 250
Maximum adiabatic short-circuit current rating (0.1/0.5/1.0 s) kA 113 / 50,4 / 35,6
(*) In air, at 40 C / Buried, at 25 C - 1,5 Km/W - 1 m (see more details in ANNEX) Signed by : J.A. Lemus
N/A = Not Applicable Date : 13/09/2013
Nominal values subject to the usual manufacturer tolerances
-
7/27/2019 GENERAL CABLE_ HEPRZ 12-20 1x400.xls
2/2
(1)
3 single-core cables in
trefoil touching
formation, with effective
air renovation.
In free air at 40C, solar radiation protected, in accordance with UNE 211435
(2)
3 single-core cables in
trefoil touching
formation, buried directin the ground.
Buried at 25C - 1,5Km/W - 1m, in accordance with UNE 211435
(3) 1 three-core cable, with
effective air renovation.In free air at 40C, solar radiation protected, calculation criteria in accordance with UNE 211435
(4) 1 three-core cable. Buried at 25C - 1,5Km/W - 1m, calculation criteria in accordance with UNE 211435
(5)
3 single-core cables in
trefoil touching
formation, with effective
air renovation.
In free air at 40C, solar radiation protected , calculation criteria in accordance with IEC 60287
(6)
3 single-core cables intrefoil touching
formation, buried direct
in the ground.
Buried at 25C - 1,5Km/W - 1m, calculation criteria in accordance with IEC 60287
Derating Factors for different installation conditions : Please contact our Technical Department
Derating Factors for different installation conditions : Please contact our Technical Department
MEDIUM VOLTAGE CABLES (FROM 1,8/3 kV UP TO 18/30 kV RADIAL FIELD)
INSTALLATION CONDITIONS DESCRIPTION
HIGH VOLTAGE CABLES (FROM 26/45 kV UP TO 127/220 kV)