Ge rm an y (280kg) - VKENvken.vn/product_pdfs/Catalog-khoa-dien-tu-YLI-YM-280-LED.pdfB. Check the...
Transcript of Ge rm an y (280kg) - VKENvken.vn/product_pdfs/Catalog-khoa-dien-tu-YLI-YM-280-LED.pdfB. Check the...
Magnetic Lock(280kg)
Specification
11
180
38
Armature Plate
Location Pin
Anti-magnetic Pin
Nut
M8X35 Screw
washer Rubber Ring
Cautions:
A. The screw of armature plate should not be fi xed t oo ti ght . Proper elasticity
sho uld b e gua ran teed for th e rub ber ring so that the armature plate can adjust
itself to the appropriate position.
B. Check the jumper's position before connecting. Figure out it represents 12VDC
or 24VDC.
!
www.yli.cn
(unit:mm)Diagram
We create security
43
38
180
11
25
500
Srew Hole
Wire Hole
Mounting Plate
43
250
25
Size(unit:mm) Voltage
12/24VDC
12/24VDC
12/24VDC
12/24VDC
Ho ding Forcel
280kgx2(600Lbsx2)
280kg(600Lbs)
280kg(600Lbs)
280kgx2(600Lbsx2)
Door
Single Door
Double Door
Single Door
Double Door
Model Current
250Lx48.5Wx25H
500Lx48.5Wx25H
250Lx48.5Wx25H
500Lx48.5Wx25H
Door Signal
No
No
12/24VDC 280kg(600Lbs) Single Door
12V/500mA
24V/250mA
12V/5
24V/2
00mAx2
50mAx2
12V/500mA
24V/250mA
12V/5
24V/2
00mAx2
50mAx2
12V/500mA
24V/250mA250Lx48.5Wx25H
YM-280D
YM-280(LED)
YM-280D(LED)
YM-280
YM-280(LED)-DS
Lock Signal
No
Yes
No
Yes
Yes
No
No
12/24VDC Double Door500Lx48.5Wx25H 280kgx2(600Lbsx2)12V/5
24V/2
00mAx2
50mAx2YM-280TD(LED) Yes No
12/24VDC Single Door250Lx48.5Wx25H12V/500mA
24V/250mAYM-280T(LED) Yes No280kg(600Lbs)
12/24VDC 280kgx2(600Lbsx2) Double Door500Lx48.5Wx25H12V/5
24V/2
00mAx2
50mAx2YM-280D(LED)-DS Yes
NO(B),NC(R)COM(Y)
NO(B),NC(R)COM(Y)
testedGermany
EMCR
www.yli.cn We create security
Installation
Drill a hole
Inside: Diameter is 8mm
Outside: Diameter is16mm
Door leaf
Drill holes based on themarked positions.
Make a combinationbased on the picture.
Hollow Metal Door Wooden Door Metal Surface Door
Drill a hole
Inside: Diameter is 8mm
Outside: Diameter is 12.7mm
Inside:Drill a hole
diameter is 8mm folding
the plastic straight pin
36mm
Steps
Fold the plate to 90 . Close the door first, then
place the upper side of
template on door frame,
while adjust the left side
next to the door leaf.
Template
Door Frame
Door leaf
Template
Door Frame
Door leaf
Template
Mark screw positions of
armature plate and magnetic
lock on door leaf and door
frame respectively.
Setpin
Strike the pin into thearmature plate slightly(to avoid movement).
Make a combination based
on the picture(add washer
accordingly).The rubber ring
must be added.
Place the rubber ring
between armature plate
and door leaf.
Allen Key
Use Allen key to removethe mounting plate fromlock body.
Rubber ring
Fix the mounting plate onthe door frame accordingto the holes drilled earlier.
Use Allen key to screwthe lock body on themounting plate.
After all the appropriateprocedures, the holdingforce can be maximized.Finally, fix the tamperscrew.
Screw door
Wire
Wire
Allen Key
Close the door to testholding force. The anglebetween armature plateand magnetic lock canbe adjusted by addingor reducing washers.
www.yli.cn We create security
Installation Instruction
Demonstration of UL BracketInstallation
Demonstration of ZL BracketInstallation
Demonstration of L BracketInstallation
Bracket Instal lat ion
Demonstration of I BracketInstallation
Different brackets are available according to different types of doors. For example,
narrow door , frameless glass door and inward opening door.
L Bracket-For outward opening door
When the door frame thickness is less than
42mm, L bracket is needed.
ZL Bracket-For inward opening door
For inward opening door, ZL bracket is
needed.
U Bracket
For the frameless glass door. U bracketis needed.
I Bracket for armature plate
When the door frame is too thick, I bracket
is needed.
Door Leaf
Frame
Armature BracketFrameless glass door
Outswing doorInswing door
Door Frame
www.yli.cn We create security
Circuit Board Diagram
Wire Connection
A.12VDC Input:
Required power 0.5Amp(Minimum).
Connect the positive(+)lead from a 12VDC
power source to V +.
Connect the ground(-)lead from a 12VDC
power source to V -.
Check jumper for 12 VDC operation.
B.24VDC Input:
Required power 0.25Amp(Minimum).
Connect the positive(+)lead from a 24VDC
power source to V +.
Connect the ground(-)lead from a 24VDC
power source to V -.
Check jumper for 24 VDC operation.
YM-280,YM-280DYM-280(LED),YM-280(LED)-DS,
YM-280D(LED),YM-280D(LED)-DS
Time delay setting
YM-280T(LED),YM-280TD(LED)
Điều Kiện Thương mại:
Sản phẩm mới 100% theo tiêu chuẩn của nhà sản xuất, cam kết chính hãng.
Quý khách vui lòng Liên hệ Vken để có báo giá chính xác của từng ngày.
Giao hàng trong vòng 02 ngày kể từ ngày ký kết hợp đồng hoặc xác nhận đơn đặt hàng.
Bảo hành theo tiêu chuẩn của nhà sản xuất.
Dịch vụ sau bán hàng:
Mọi chi tiết về thông số kỹ thuật của thiết bị, Quý khách vui lòng liên hệ tới VKEN :
0904 954 981
CATALOGUES
VKEN chúng tôi trân trọng gửi tới Quý Khách Hàng một số thông tin về sản phẩm do VKEN cung cấp, chúng tôi cam kết hàng bán
ra thị trường đều là chính hãng chất lượng cao. Rất mong nhận được sự hợp tác từ quý khách . Xin cảm ơn !
Kính chào Quý Khách Hàng !
VKEN xin cam kết với Quý Khách hàng trong thời hạn bảo hành thiết bị, công ty miễn phí bảo hành trong thời gian bảo hành . Trong
trường hợp thiết bị gặp sự cố, Vken sẽ nhánh chóng cử cán bộ kỹ thuật khắc phục trong vòng 02h kể từ khi nhận được thông báo
của Khách hàng !
Giới Thiệu về Vken : Vken Chuyên cung cấp: Các giải pháp an ninh giám sát, kiểm soát ra vào , quản lý nhân sự,hệ thống kiểm
soát ra vào tòa nhà.... cho các công trình, toà nhà, dự án lớn. VKEN Company luôn đảm bảo cung cấp đến khách hàng các sản
phẩm chính hãng với chất lượng tốt nhất, đáp ứng nền tảng công nghệ mới với giá cả phải chăng nhất.
Hotline:
CÔNG TY CỔ PHẦN THÀNH AN
Địa chỉ: Tầng 5 - Số 184 Nguyễn Tuân - Thanh Xuân- Hà nội Tel: 0904 954 981 Email: [email protected]
MST: 0101219662
Website: www.Vken.vn