GE Healthcare Project Management A-1

3
GE Healthcare has made reasonable efforts to ensure this BIM file conforms to requirements of the applicable pre-installation manual. This BIM file was produced to assist with site planning and is not intended for construction or final building modeling. GE Healthcare is not responsible for any damages resulting from use of such file for construction or final building modeling purposes. Compliance with all applicable local, state, and federal laws and regulations is the responsibility of the customer or its designated architects and engineers. Please keep in mind the information in this BIM file is dynamic and is subject to change without notice. It is the responsibility of the customer or its designated architect(s) and engineer(s) to ensure they have the latest equipment or product information. Scale Project number Date Drawn by Checked by GE Healthcare Project Management 12" = 1'-0" A-1 DISCOVERY NMCT670 DR - RENDERING 7-92 25.SEP.17 GENPACT

Transcript of GE Healthcare Project Management A-1

Page 1: GE Healthcare Project Management A-1

GE Healthcare has made reasonable efforts to ensure this BIM file conformsto requirements of the applicable pre-installation manual. This BIM file wasproduced to assist with site planning and is not intended for construction orfinal building modeling. GE Healthcare is not responsible for any damagesresulting from use of such file for construction or final building modelingpurposes. Compliance with all applicable local, state, and federal laws andregulations is the responsibility of the customer or its designated architectsand engineers. Please keep in mind the information in this BIM file isdynamic and is subject to change without notice. It is the responsibility ofthe customer or its designated architect(s) and engineer(s) to ensure theyhave the latest equipment or product information. Scale

Project numberDateDrawn byChecked by

GE HealthcareProject Management

12" = 1'-0"

A-1

DISCOVERY NMCT670 DR - RENDERING

7-9225.SEP.17GENPACT

Page 2: GE Healthcare Project Management A-1

[4.39 m]

14' - 5"

[8.3

8 m

]

27' -

6"

[2.0

8 m

]

6' -

10"

GE Healthcare has made reasonable efforts to ensure this BIM file conformsto requirements of the applicable pre-installation manual. This BIM file wasproduced to assist with site planning and is not intended for construction orfinal building modeling. GE Healthcare is not responsible for any damagesresulting from use of such file for construction or final building modelingpurposes. Compliance with all applicable local, state, and federal laws andregulations is the responsibility of the customer or its designated architectsand engineers. Please keep in mind the information in this BIM file isdynamic and is subject to change without notice. It is the responsibility ofthe customer or its designated architect(s) and engineer(s) to ensure theyhave the latest equipment or product information. Scale

Project numberDateDrawn byChecked by

GE HealthcareProject Management

1/8" = 1'-0"

A-2

DISCOVERY NMCT 670 DR - PLAN & SCHEDULE

7-9225.SEP.17GENPACT

Specialty Equipment Schedule

Description Weight (lbs) BTUCONTROL ROOMFREEDOM WORKSPACE|LARGE TABLE 147 8191ESTOP PUSHBUTTON 0 0XELERIS WORK STATION 55 255EXAM ROOMSTORAGE CABINET 99 0R-WAVE RECORDER 6 0OPERATORS CONSOLE 194 0DISCOVERY NM/CT 670 DR|GANTRY 10018 18771UPS SYSTEM 350 3399POWER DISTRIBUTION UNIT 815 5119POWER INPUT DISTRIBUTION BOX 22 0MAIN DISCONNECT CONTROL 90 0COLLIMATOR CART 1058 0TABLE 1521 0

Page 3: GE Healthcare Project Management A-1

Hold the Left Click for Rotating aroundUse the Scroll for Zooming in and out

Click for Site Planning Support