GE Germicidal Lamps - interlight Germicidal... · 2007. 12. 20. · g GE Germicidal Lamps G4T5...

50
GE Germicidal Lamps g G4T5 Benefits UV output at 254 nm; emits no ozone Effective in killing most microorganisms Uses mini Bi-pin end caps 6000 hours Useful Life Product Description Product Code Case Quantity Bulb Designation Bulb Material Dimensions Min Max Base face to base face (A) in. (mm) 5.35(135.9) Base face to end of opposite base pin (B) in. (mm) 5.53(140.5) 5.63(143) End of base pin to end of opposite pin end (C) in. (mm) -- 5.91(150.1) Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0) Nominal Lamp Power at 25° C, 100 hrs Watts Nominal Lamp Volts at 25° C, 100 hrs V rms Nominal Lamp Current at 25° C, 100 hrs A rms Peak Emission Wavelength nm Irradiance @ 1m, 254 nm, 100 hrs µ W/cm 2 UV Output @ 254 nm, 100 hrs Watts Useful Life (80% initial output) Hours DoE regulated (yes/no) ANSI/IESNA G4T5 15872 24 Physical Characteristics Applicable Standards no RP-27.4-96 T5 Soft Glass - Turn power off before inspection, installation or removal Electrical Characteristics Risk of electric shock Applicable Regulations 8.3 0.8 6,000 - Avoid exposure of eyes and skin to unshielded lamp Warning Lamp emits UV radiation which may cause eye/skin injury. RG-3 4 29 170 253.7 UV Characteristics Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement. All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage. Where applicable, values are based on guidelines published in ANSI. * Values shown are based on preliminary engineering estimates

Transcript of GE Germicidal Lamps - interlight Germicidal... · 2007. 12. 20. · g GE Germicidal Lamps G4T5...

  • GE Germicidal LampsgG4T5

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    • Uses mini Bi-pin end caps

    • 6000 hours Useful Life

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 5.35(135.9)Base face to end of opposite base pin (B) in. (mm) 5.53(140.5) 5.63(143)End of base pin to end of opposite pin end (C) in. (mm) -- 5.91(150.1)Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G4T515872

    24Physical Characteristics

    Applicable Standardsno

    RP-27.4-96

    T5Soft Glass

    - Turn power off before inspection, installation or removal

    Electrical Characteristics

    Risk of electric shock

    Applicable Regulations

    8.30.8

    6,000

    - Avoid exposure of eyes and skin to unshielded lamp

    WarningLamp emits UV radiation which may cause eye/skin injury. RG-3

    429

    170

    253.7UV Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG4T5

    UV Maintenance

    0%

    20%

    40%

    60%

    80%

    100%

    120%

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG6T5

    • Uses mini Bi-pin end caps

    • 6000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 8.35(212.1)Base face to end of opposite base pin (B) in. (mm) 8.53(216.7) 8.63(219.2)End of base pin to end of opposite pin end (C) in. (mm) -- 8.91(226.3)Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G6T515873

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics642

    160UV Characteristics

    253.717.71.7

    6,000Warning

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG6T5

    UV Maintenance

    0%

    20%

    40%

    60%

    80%

    100%

    120%

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG8T5

    • Uses mini Bi-pin end caps

    •7500 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 11.35(288.3)Base face to end of opposite base pin (B) in. (mm) 11.53(292.9) 11.63(295.4)End of base pin to end of opposite pin end (C) in. (mm) -- 11.91(302.5)Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    24*2.3*

    7,500Warning

    570.145

    UV Characteristics253.7

    T5Soft Glass

    Electrical Characteristics8

    G8T511077

    24Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG8T5

    Relative UV MaintenanceG8T5

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG11T5

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    • Uses mini Bi-pin end caps

    • 8000 hours Useful Life

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 8.35(212.1)Base face to end of opposite base pin (B) in. (mm) 8.53(216.7) 8.63(219.2)End of base pin to end of opposite pin end (C) in. (mm) 8.91(226.3)Bulb Outside Diameter (D) in. (mm) 0.58(14.7) 0.64(16.3)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    noApplicable Standards

    RP-27.4-96

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    2.28,000

    Special CharacteristicsLamp emits UV radiation which may cause eye/skin injury. RG-3

    0.330UV Characteristics

    253.722.9

    Soft Glass

    Electrical Characteristics1137

    2949524

    Physical CharacteristicsT5

    G11T5

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG11T5

    Relative UV MaintenanceG11T5

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG11T5/4P/SE

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    • Uses a single 4pin end cap• 8000 hours Useful Life

    33mm 8.3mm

    7.9mm

    L

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (L) in. (mm)Bulb Outside Diameter (D) in. (mm) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G11T5/4P/SE29500

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics1137

    Special CharacteristicsLamp emits UV radiation which may cause eye/skin injury. RG-3

    0.330UV Characteristics

    253.722.9

    noApplicable Standards

    RP-27.4-96

    8.66(220)

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    2.28,000

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG11T5/4P/SE

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Relative UV MaintenanceG11T5/4P/SE

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG36T5

    • Uses single-pin end caps

    • 9000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 33.37(847.5)Base face to end of opposite base pin (B) in. (mm) 32.89(835.5) 33.72(856.5)End of base pin to end of opposite pin end (C) in. (mm) -- 34.07(865.5)Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G36T515874

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics39

    107425

    UV Characteristics253.7109.5

    129,000

    WarningLamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG36T5

    UV Maintenance

    0%

    20%

    40%

    60%

    80%

    100%

    120%

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG36T5/4P/SE

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    • Uses a single 4pin end cap• 8000 hours Useful Life

    33mm 8.3mm

    7.9mm

    L

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (L) in. (mm)Bulb Outside Diameter (D) in. (mm) 0.64(16.3)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G36T5/4P/SE29503

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics39115

    Special CharacteristicsLamp emits UV radiation which may cause eye/skin injury. RG-3

    0.425UV Characteristics

    253.7109.5

    noApplicable Standards

    RP-27.4-96

    33.28(845.4)

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    12.09,000

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG36T5/4P/SE

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Relative UV MaintenanceG36T5/4P/SE

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG64T5

    • Uses single-pin end caps

    • 7500 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 61.30(1557)Base face to end of opposite base pin (B) in. (mm) 61.42(1560.1) 61.65(1565.9)End of base pin to end of opposite pin end (C) in. (mm) 61.74(1568.2) 62.00(1574.8)Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    18518

    7,500Warning

    1800.425

    UV Characteristics253.7

    T5Soft Glass

    Electrical Characteristics65

    G64T515864

    24Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal Lampsg

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    G64T5

    Relative UV MaintenanceG64T5

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG64T5/4P/SE

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    • Uses a single 4pin end cap• 8000 hours Useful Life

    33mm 8.3mm

    7.9mm

    L

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (L) in. (mm)Bulb Outside Diameter (D) in. (mm) 0.64(16.3)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G64T5/4P/SE29504

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics65

    250

    Special CharacteristicsLamp emits UV radiation which may cause eye/skin injury. RG-3

    0.425UV Characteristics

    253.7200

    noApplicable Standards

    RP-27.4-96

    61.28(1556.6)

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    25.09,000

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG64T5/4P/SE

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Relative UV MaintenanceG64T5/4P/SE

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG10T8

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 13.05(331.5)Base face to end of opposite base pin (B) in. (mm) 13.24(336.2) 13.33(338.6)End of base pin to end of opposite pin end (C) in. (mm) -- 13.61(345.7)Bulb Outside Diameter (D) in. (mm) 1.05(26.7)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G10T829498

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics9.546

    0.230UV Characteristics

    253.728.12.7

    6,000Special Characteristics

    Lamp emits UV radiation which may cause eye/skin injury. RG-3

    noApplicable Standards

    RP-27.4-96

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG10T8

    Relative UV MaintenanceG10T8

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG15T8

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 17.22(437.4)Base face to end of opposite base pin (B) in. (mm) 17.40(442) 17.50(444.5)End of base pin to end of opposite pin end (C) in. (mm) 17.67(448.8) 17.78(451.6)Bulb Outside Diameter (D) in. (mm) 0.94(23.9) 1.10(27.9)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    49*4.8*

    8000*Warning

    550.305

    UV Characteristics253.7

    T8Soft Glass

    Electrical Characteristics15

    G15T811078

    24Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal Lampsg

    Relative UV MaintenanceG15T8

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    G15T8

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG25T8

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 17.22(437.4)Base face to end of opposite base pin (B) in. (mm) 17.40(442) 17.50(444.5)End of base pin to end of opposite pin end (C) in. (mm) 17.67(448.8) 17.78(451.6)Bulb Outside Diameter (D) in. (mm) 0.94(23.9) 1.10(27.9)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    70*6.9*

    8000*Warning

    460.580

    UV Characteristics253.7

    T8Soft Glass

    Electrical Characteristics25

    G25T811082

    24Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal Lampsg

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    G25T8

    Relative UV MaintenanceG25T8

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG30T8

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 35.22(894.6)Base face to end of opposite base pin (B) in. (mm) 35.40(899.2) 35.50(901.7)End of base pin to end of opposite pin end (C) in. (mm) 35.67(906.0) 35.78(908.8)Bulb Outside Diameter (D) in. (mm) 0.94(23.9) 1.10(27.9)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G30T811080

    24Physical Characteristics

    T8Soft Glass

    Electrical Characteristics3099

    0.355UV Characteristics

    253.7125*12.4*8000*

    WarningLamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal Lampsg

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    G30T8

    Relative UV MaintenanceG30T8

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG36T8

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 47.22(1199.4)Base face to end of opposite base pin (B) in. (mm) 47.41(1204.1) 47.50(1206.5)End of base pin to end of opposite pin end (C) in. (mm) -- 47.78(1213.6)Bulb Outside Diameter (D) in. (mm) 0.96(24.3) 1.05(26.7)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G36T829499

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics36

    1030.430

    UV Characteristics253.714514.68,000

    Special CharacteristicsLamp emits UV radiation which may cause eye/skin injury. RG-3

    noApplicable Standards

    RP-27.4-96

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG36T8

    Relative UV MaintenanceG36T8

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG55T8/HO

    • Uses medium bi-pin end caps

    • High-Output UV emitter

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 35.22(894.6)Base face to end of opposite base pin (B) in. (mm) 35.40(899.2) 35.50(901.7)End of base pin to end of opposite pin end (C) in. (mm) 35.40(899.2) 35.78(908.8)Bulb Outside Diameter (D) in. (mm) 0.94(23.9) 1.10(27.9)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    19418

    8,000Warning

    830.770

    UV Characteristics253.7

    T8Soft Glass

    Electrical Characteristics55

    G55T8/HO15875

    24Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal Lampsg

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    G55T8/HO

    Relative UV MaintenanceG55T8/HO

    00.20.40.60.8

    11.2

    0 2000 4000 6000 8000 10000Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG20T10

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 23.22(589.8)Base face to end of opposite base pin (B) in. (mm) 23.40(594.4) 23.50(596.9)End of base pin to end of opposite pin end (C) in. (mm) -- 23.78(604)Bulb Outside Diameter (D) in. (mm) 1.22(31.0) 1.34(34.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA RP-27.4-96

    - Turn power off before inspection, installation or removalApplicable Regulations

    noApplicable Standards

    Special CharacteristicsLamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock

    8,000

    G20T1015876

    24Physical Characteristics

    1958

    0.360

    253.7

    7.575.8

    Electrical Characteristics

    T5Soft Glass

    UV Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG20T10

    Relative UV MaintenanceG20T10

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG40T10

    • Uses standard Bi-pin end caps

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb Material

    Dimensions Min MaxBase face to base face (A) in. (mm) 47.22(1199.4)Base face to end of opposite base pin (B) in. (mm) 47.40(1204) 47.50(1206.5)End of base pin to end of opposite pin end (C) in. (mm) -- 47.78(1213.6)Bulb Outside Diameter (D) in. (mm) 1.34(34.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    G40T1029532

    24Physical Characteristics

    T5Soft Glass

    Electrical Characteristics40106

    0.420UV Characteristics

    253.720019.8

    8,000Special Characteristics

    Lamp emits UV radiation which may cause eye/skin injury. RG-3

    noApplicable Standards

    RP-27.4-96

    - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulations

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgG40T10

    Relative UV MaintenanceG40T10

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal Lampsg

    • Uses single-end 4-pin cap

    • 9000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    33mm

    8.3mm7.9m

    mL

    GPH793/T5/4

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase face to base face (A) in. (mm) 31.34(796)Base face to end of opposite base pin (B) in. (mm) -- --End of base pin to end of opposite pin end (C) in. (mm) -- --Bulb Outside Diameter (D) in. (mm) 0.53(13.5) 0.63(16.0)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    13112.8

    9,000Warning

    1050.425

    UV Characteristics253.7

    T5Quartz

    Electrical Characteristics37

    GPH793T5L/4P46630

    12Physical Characteristics

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgGPH793/T5/4

    UV Maintenance

    0%

    20%

    40%

    60%

    80%

    100%

    120%

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rela

    tive

    UV O

    utpu

    t

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgGBX5/UVC

    • Uses single-end G23

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    H

    C

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 3.35(85.0)width of lamp dimension C in. (mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) -- 0.71(18.1)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    18,000

    Warning

    350.180

    UV Characteristics253.7

    T4Soft Glass

    Electrical Characteristics5

    G23

    GBX5/UVC16479100

    Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgGBX9/UVC

    • Uses single-end G23

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    H

    C

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 5.71(145)width of lamp dimension C in. (mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) -- 0.71(18.1)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    2.48,000

    Warning

    590.180

    UV Characteristics253.7

    T4Soft Glass

    Electrical Characteristics9

    G23

    GBX9/UVC15877100

    Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgGBX11/UVC

    • Uses single-end G23

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    H

    C

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 8.46(215)width of lamp dimension C in. (mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) -- 0.71(18.1)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    3.68,000

    Warning

    890.160

    UV Characteristics253.7

    T4Soft Glass

    Electrical Characteristics11

    G23

    GBX11/UVC15879100

    Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgGBX13/UVC

    • Uses single-end G23

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    H

    C

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 6.69(170)width of lamp dimension C in. (mm) -- 1.28(32.5)depth of lamp dimension G in. (mm) -- 0.71(18.1)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    GBX13/UVC15879100

    Physical CharacteristicsT4

    Soft Glass

    Electrical Characteristics13

    G23

    590.285

    UV Characteristics253.7

    3.68,000

    WarningLamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgC

    H

    GBX18/UVC/2G11

    • Uses single-end G2-11

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 8.8(225)width of lamp dimension C in. (mm) -- 1.73(44)depth of lamp dimension G in. (mm) -- 0.9(24)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance† @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    GBX18/UVC/2G1115882

    40Physical Characteristics

    T6Soft Glass

    Electrical Characteristics18

    2G11

    590.380

    UV Characteristics253.7

    695.3

    8,000Warning

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    † measured perpendicular to the biax plane

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgC

    H

    GBX36/UVC/2G11

    • Uses single-end G2-11

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 16.33(415)width of lamp dimension C in. (mm) -- 1.73(44)depth of lamp dimension G in. (mm) -- 0.9(24)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance† @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    15512

    8,000Warning

    1070.440

    UV Characteristics253.7

    T6Soft Glass

    Electrical Characteristics36

    2G11

    GBX36/UVC/2G1115882

    40Physical Characteristics

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    † measured perpendicular to the biax plane

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgC

    H

    GBX55/UVC/2G11

    • Uses single-end G2-11

    • 8000 hours Useful Life

    Benefits• UV output at 254 nm; emits no ozone

    • Effective in killing most microorganisms

    Product DescriptionProduct CodeCase Quantity

    Bulb DesignationBulb MaterialBase -- non-integral single ended 4 pin ceramic base

    Dimensions Min MaxBase DimensionsBase face to top of lamp diemsnion--H in. (mm) -- 21.1(535)width of lamp dimension C in. (mm) -- 1.73(44)depth of lamp dimension G in. (mm) -- 0.9(24)

    Nominal Lamp Power at 25° C, 100 hrs WattsNominal Lamp Volts at 25° C, 100 hrs V rmsNominal Lamp Current at 25° C, 100 hrs A rms

    Peak Emission Wavelength nmIrradiance† @ 1m, 254 nm, 100 hrs µW/cm2

    UV Output @ 254 nm, 100 hrs WattsUseful Life (80% initial output) Hours

    DoE regulated (yes/no)

    ANSI/IESNA

    GBX55/UVC/2G1115885

    25Physical Characteristics

    T6Soft Glass

    Electrical Characteristics55

    2G11

    1010.550

    UV Characteristics253.724016.5

    8,000Warning

    Lamp emits UV radiation which may cause eye/skin injury. RG-3 - Avoid exposure of eyes and skin to unshielded lampRisk of electric shock - Turn power off before inspection, installation or removal

    Applicable Regulationsno

    Applicable StandardsRP-27.4-96

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    † measured perpendicular to the biax plane

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • GE Germicidal LampsgGermicidal Biax Lamps

    Percent IrradianceGermicidal Lamps

    0%

    20%

    40%

    60%

    80%

    100%

    100 200 300 400 500 600

    Wavelength (nm)

    Germicidal Effectiveness

    0%

    20%

    40%

    60%

    80%

    100%

    200 225 250 275 300 325

    Wavelength (nm)

    Rela

    tive

    Effe

    ctiv

    enes

    s

    254 nm

    Relative UV Maintenance

    0

    0.2

    0.4

    0.6

    0.8

    1

    1.2

    0 2000 4000 6000 8000 10000

    Time (hours)

    Rel

    ativ

    e U

    V O

    utpu

    t

    Turn power off and let lamp cool before removal to avoid potential burn and electrical shock hazard during lamp replacement.

    All values are design values or typical values when measured under laboratory conditions. Information provided is subject to change without notice. Germicidal efficacy is dependant upon use of proper engineering design guidelines & UV dosage.

    Where applicable, values are based on guidelines published in ANSI.

    * Values shown are based on preliminary engineering estimates

    AaronINT Stamp

    http://www.interlight.biz

  • UV lamps forgermicidal applications.Water, air and surface sterilization.

    GE Consumer & IndustrialSpecialty Lighting

    imagination at work

    AaronINT Stamp

    http://www.interlight.biz

  • Germicidal LampsLinear fluorescent and compact fluorescent types

    GE Germicidal lamps use a special glass thattransmits ultra-violet light in a spectral bandthat can be effective for sterilization. A proventechnology for the destruction of air-bornebacteria, viruses and mold spores.Improved system efficiency when installed inHVAir Conditioning (HVAC) units by reducingbacterial and mold growth. The UVCwavelength of 254 nm will inactivate bacteria,viruses, mold, and cysts by preventing DNAreplication.

    AaronINT Stamp

    http://www.interlight.biz

  • Germicidal ApplicationsUV lamps for germicidal applications. Water, air and surfacesterilization.HealthcareUVC is used to reduce the spread of disease, protecting both patients and staff. UV fixtures are often found in areaswhere the risk of infection is greatest; such as immuno-compromised patient areas or where the probability oftransmission is high.

    Processing IndustryFood may be irradiated to prevent growth of mold and other dangerous organisms before it is packaged. This helpsensure food safety and extends shelf life. UVC lamps are also used within the facility to limit the exposure of foodproducts to airborne micro-organisms.

    Scientific LabsIn industries that demand a clean, sterile environment, UVC is used to limit the amount of ‘live’ organisms in the air,and to sterilize equipment and surfaces when employees are not in the room.

    Industrial, Municipal, Residential Water and Pond TreatmentSpecial UVC lamps are used in some treatment applications as a means of disinfection. This technology serves as areplacement for chlorination in waste water treatment and as an additional protective barrier in drinking andprocess water applications.Lamps are now widely used in Pond cleansing for both domestic and commercial uses.

    Commercial buildingsUVC lamps are used as a means of improving HVAC system efficiencies by irradiating coils and keeping them frombuilding up with mold and other bacteria, which reduces the flow rate and costs more to operate. These lamps canalso be installed in-duct as a means of improving indoor air quality.

    Food processing industry• Food processing• Food handling• Warehousing• Produce department• Meat cases• Salad bars• Dessert cases• Bakeries• Buffets• Restaurants

    Biotech industry• Bioengineering• Genetics• Medical testing• Pharmaceutical processes• Research labs• Biotech labs• Equipment sterilization

    AaronINT Stamp

    http://www.interlight.biz

  • Germicidal lamps range

    GE Consumer & Industrial is constantly developing and improving its products. For this reason, allproduct descriptions in this brochure are intended as a general guide, and we may changespecifications time to time in the interest of product development, without prior notification or publicannouncement. All descriptions in this publication present only general particulars of the goods towhich they refer and shall not form part of any contract. Data in this guide has been obtained incontrolled experimental conditions. However, GE Consumer & Industrial cannot accept any liabilityarising from the reliance on such data to the extent permitted by law.Germicidal Lamps - English - January 2006

    and General Electric are both registered trademarks of the General Electric Company, USA

    © General Electric Company (USA) 2006

    Length Length Product UV Output Irradiance Rated Pack ProductWatt inch mm Description (Watts) (µW/cm2) Life Hours Qty CodeGermicidalSoft Glass UV Output (Watts) Efficacy

    T5 Germicidal4 5.91 150.1 G4T5 0.9 8.3 6000 24 158726 8.91 226.3 G6T5 1.7 17.7 6000 24 158738 11.91 302.5 G8T5 2.3 24.0 7500 24 11077

    11 226.3 8.91 G11T5 2.2 22.9 8000 24 2949516 11.91 302.5 G16T5 3.2 33.0 8000 24 1649436 34.07 865.5 G36T5 12 109.5 9000 24 1587464 62.00 1574.8 G64T5 18 185.0 7500 24 15864

    T5 Germicidal Single 4pin cap11 8.66 220 G11T5/4P/SE 2.2 22.9 8000 24 2950016 12.61 320.3 G16T5/4P/SE 3.4 33.0 8000 24 2950236 33.28 845.4 G36T5/4P/SE 12 109.5 9000 24 2950364 61.28 1556.6 G64T5/4P/SE 25 200.0 9000 24 29504

    T5 Germicidal Single 4pin cap37 31.34 796 GPH793T5L/4P 12.8 131.0 9000 12 46630

    T8 Germicidal10 13.61 345.7 G10T8 2.7 27.6 6000 24 2949815 17.78 451.6 G15T8 4.8 49.0 8000 24 1107825 17.78 451.6 G25T8 6.9 70.0 8000 24 1108230 35.78 908.8 G30T8 12.4 125.0 8000 24 1108036 47.78 1213.6 G36T8 14.6 145.0 8000 24 2949955 35.78 908.8 G55T8HO 18 194.0 8000 24 15875

    T10 Germicidal20 23.78 604 G20T10 7.5 75.8 8000 24 1587640 47.78 1213.6 G40T10 19.8 200.0 8000 24 29532

    Biax™ Germicidal5 3.35 85.0 GBX5/UVC G23 1.0 9.0 8000 100 406959 5.71 145.0 GBX9/UVC G23 2.4 22.0 8000 100 40696

    11 8.46 215.0 GBX11/UVC G23 3.6 33.0 8000 100 4070013 6.69 170.0 GBX13/UVC GX23 3.6 31.0 8000 100 4070318 8.8 225.0 GBX18/UVC/2G11 5.3 51.0 8000 40 15882/4070436 16.33 415 GBX36/UVC/2G11 12 110.0 8000 40 15883/4070555 21.1 535 GBX55/UVC/2G11 16.5 156.0 8000 25 15885/40706

    AaronINT Stamp

    http://www.interlight.biz

  • SPECIALTYLIGHTINGLIGHTING

    GE Lighting

    UV lamps for germicidal applications...water, air and surface sterilization.

    GE Germicidal lamps use a special UV transmitting glass that canbreak down ultraviolet light in a spectral band for sterilization.

    The UVC wavelength of 254 nm will inactivate bacteria, viruses,mold, and cysts by preventing DNA replication.

    Typical Applications Areas

    Healthcare: UVC is used to reducethe spread of disease, protectingboth patients and staff. UV fixturesare often found in areas where therisk of infection is greatest; such asimmuno compromised patientareas or where the probability oftransmission is high.

    Food Processing Industry: Foodmay be irradiated to preventgrowth of mold and other dangerous organisms before it is packaged. This helps ensurefood safety and extends shelf life.UVC lamps are also used withinthe facility to limit the exposureof food products to airbornemicro-organisms.Scientific Labs: In industries thatdemand a clean, sterile environment, UVC is used to limit the amount

    of ‘live’ organisms in the air, and to sterilize equipment and surfaces whenemployees are not in the room.Industrial, Municipal and ResidentialWater Treatment: Special UVC lamps areused in some treatment applications as ameans of disinfection. This technologyserves as a replacement for chlorinationin waste water treatment and as an additional protective barrier in drinkingand process water applications.

    GE SPECIALTY LIGHTING / GERMICIDAL LAMPS

    germicidal product sheet-revise 2/5/04 9:48 PM Page 1

    AaronStamp for PDF

    www.interlight.biz

  • GE SPECIALTY LIGHTING / GERMICIDAL LAMPS

    imagination at work

    26153 (2/04)Printed in USA

    For complete Germicidal Lighting product information, visit the GE Website at www.gelighting.com

    germicidal product sheet-revise 2/5/04 9:51 PM Page 2

    AaronStamp for PDF

    www.interlight.biz