Page 1: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

C146-E190A

Gas Chromatograph Mass Spectrometer

GCMS-TQ8030

Page 2: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

The number and diversity of chemical substances that can harm the environment

or organisms continues to increase significantly. Chemists need to measure these

contaminants quickly and accurately, but sample pretreatment and interference

from complex matrices remain a problem. A solution to these challenges has

arrived. The solution is the GCMS-TQ8030 Triple Quadrupole Gas Chromatograph

Mass Spectrometer, which provides the speed, accuracy, and easy operation

scientists want.

Page 3: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

LCMS-8080LCMS-8030 LCMS-8040 LCMS-IT-TOFGCMS-QP2010 UltraGCMS-QP2010 SE GCMS-TQ8030

LCMS-2020

PP. 6–7

Ultimate Ease of Use

• AART function automatically adjusts compound and MRM retention times• Easy sTop injection port reduces maintenance downtime• Front-opening ion source chamber makes maintenance fast and easy

• UFsweeper® allows 600 MRM transitions per second• ASSP™ permits high-speed scanning at 20,000 u per second• Fast Scan/MRM measurements provide a wealth of qualitative and quantitative information

High Sensitivity and Enhanced Selectivity

• Shimadzu's proprietary, high-efficiency ion source offers unmatched sensitivity• Overdrive lenses reduce neutral noise• Variety of measurement modes provide enhanced selectivity and method flexibility

PP. 8–9

PP. 10–11

High-Speed Performance

Page 4: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

High-Sensitivity Ion SourceThe effect of filament potential on the ion source is reduced by placing more

distance between the filament and ion source box. In addition, a shield blocks

out radiant heat generated from the filament to ensure the ion source box

temperature remains uniform. Since this prevents any active spots within the

ion source, it provides higher sensitivity for analysis. (Patent: US7939810)

GCMS-TQ8030 Technology

Shimadzu's proprietary UFsweeper® technology efficiently

sweeps residual ions from the collision cell to provide high CID

efficiency and fast ion transport. Rapid ion removal minimizes

cross-talk and enables trace analysis (patent pending).

High-Efficiency Collision Cell UFsweeper®

4

Page 5: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

High-Speed Scanning Control(Advanced Scanning Speed Protocol, ASSP™)

Overdrive lens OFF Overdrive lens ON

Noise Elimination by Overdrive Lenses

Noise

Sample

Correlation Between Applied Voltage toOverdrive Lenses and S/N

Applied voltage (V) -1000

Noise

S/N ratio

Ion detection signal

The rod bias voltage is dynamically optimized during ultrahigh-speed data acquisition,

thereby minimizing the drop in sensitivity that would otherwise occur above 10,000 u/sec.

This is necessary for increasing sensitivity in high-speed scan data and acquiring superior

mass spectra when performing product ion scans or simultaneous scan and

MRM measurement in the scan/MRM mode. (Patent: US6610979)

Overdrive Lenses (Noise Elimination Technology)

Two lenses (overdrive lenses) positioned in front of the electron multiplier reduce random

noise from helium, high-speed electrons, or other factors, and improve the S/N ratio.

Applying voltage to the lenses improves the S/N level by reducing noise components near

the lenses and focusing the ions that pass through the mass filter. (Patent: US6737644)

5Gas Chromatograph Mass Spectrometer

Page 6: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

High Sensitivity and Enhanced Selectivity

MS/MS Analysis of Samples with Complex Matrices

MRM Measurement Using GC/MS/MS

Because GC/MS systems are able to identify individual

components using retention time and mass spectra,

they are especially useful for detecting trace-level

contaminants in a variety of sample types. However,

unambiguous identification can be difficult in the

presence of a complex or problematic matrix.

Multiple Reaction Monitoring (MRM) in GC/MS/MS

systems separates masses in two stages, making the

instrument significantly more selective than a single

quadrupole system. As a result, even components that

cannot be analyzed by conventional scan or SIM modes

can be easily identified and quantified in the presence of

complex matrices using MRM. For example, MRM can be

a particularly effective measurement tool for analyzing

residual pesticides in food.

SIM MRM

Foods

Environment

Life Sciences

Foods: Analysis of residual pesticides (isoprothiolane 1 μg/L) in ginger

Environment: Analysis of PBDEs (hexa-BDE (BDE-153)) in sediment

Life Sciences: Analysis of metabolites (suberic acid) in rat urine

6

Page 7: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

Example of Screening Analysis Using Neutral Loss Scan

High-Sensitivity Analysis by Single GC/MS Mode

The high-efficiency ion source provides the foundation of

an ion generation and transmission system which

efficiently creates, then delivers, ions to the detector,

resulting in a GCMS with the highest sensitivity

specification in its class. This achieves high sensitivity not

only for MRM measurements by GC/MS/MS, but also for

scan and SIM measurements by GC/MS.

This method selectively detects precursor ions with a

specific neutral loss. For example, neutral loss scans at

m/z 35 and 37 are representative of compounds

containing chlorine, and can be used to identify target

analytes such as PCBs in complex matrices.

Variety of Measurement Modes

The GCMS-TQ8030 offers a wide variety of measurement

modes, including MRM, scan, combination scan/MRM,

neutral loss scan, and others.

Scan measurement and similarity search of peaks detected by neutral loss scan

Chromatogram of Transformer Oil Spiked with PCBsBlack: Scan modeRed: Neutral loss scan mode

High Sensitivity Scan Analysis of Simazine(10ppb)

Library SpectrumMeasured Spectrum

Measured spectrum

Library spectrum

7Gas Chromatograph Mass Spectrometer

Page 8: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

High-Speed Performance

Fast Scanning Analysis with ASSP™

Propyzamide

Diazinon

Conventional Technology Newly Patented Technology (ASSP™)

The GCMS-TQ8030 is equipped with an internal firmware

protocol that optimizes the ion transmission parameters

during the scan acquisition process.

This technology, called Advanced Scanning Speed

Protocol (ASSP™), is the key to this instrument’s ability

to acquire high-quality spectra at scan speeds of up to

20,000 u/second.

Variation of Chromatogram Intensity at Each Scan SpeedAt scan speeds above 10,000 u/sec, the ASSP™ function ensures ions are accelerated at optimal voltage and inhibits any drop in signal intensity across a broad m/z range.

UFsweeper® is a unique technology created by Shimadzu

that minimizes collision cell length, while providing high

CID efficiency and high ion transport speed. UFsweeper

accelerates ions out of the collision cell by forming a

pseudo-potential surface, as shown in the illustration

below. This prevents any drop in signal intensity or

cross-talk, even at fast measurement speeds.

Conventional Technology

UFsweeper® Technology Effectively Accelerates Ions Out of the Collision Cell

Ions lose momentum due to collision with gas. UFsweeper® accelerates ions through the collision cell withoutlosing momentum.

UFsweeper®

Black:1,111u/secRed:5,000u/secBlue:10,000u/sec

8

Page 9: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

Scan/MRM Analysis

Scan/MRM is a data acquisition technique that allows the

user to collect scan data and MRM data in a single

analysis. It is used in the dual role of collecting qualitative

scan data, while monitoring MRM transitions for

additional confirmation. A high-speed scanning rate of

20,000 u/second allows full spectrum scans within a series

of MRM measurements, providing confirmation of target

compounds with information-rich product ion spectra.

To qualitatively and quantitatively analyze compounds

accurately, a minimum number of measurement points

per peak is required. The GCMS-TQ8030 allows 600

MRM/sec measurement speeds, even in the scan/MRM

mode, ensuring more data points for more accurate

qualitative and quantitative analysis.

Scan 0.05 sec

MRM 0.1 sec

High-Speed MRM Measurement

High-resolution gas chromatography is characterized by

sharp peaks with narrow peak widths, and requires

detectors with the ability to collect data at a fast

acquisition rate. Scan speeds of 20,000 u/second and

high-speed MRM measurements facilitated by

UFsweeper® make high-speed MRM acquisition possible.

The following chromatogram illustrates analysis of 13

pharmaceutical ingredients using fast-GC and 600 MRM

transitions per second.

1:Valproic acid-TMS, 2:Uracil-TMS, 3:Nicotinamide-TMS, 4:Cotinine, 5:Lidocaine-TMS, 6:Caffeine,

7:Theophylline-TMS, 8:3-Isobutyl-1-methylanxthine-TMS, 9:Atropine-TMS,

10:Promethazine,11:Clomipramine, 12:Quetiapine-TMS, 13:Trazodone

MRM Analysis of Pharmaceuticals Using Fast-GC (at 600 MRM/sec)

MRM Transition and Reproducibility

Adipic acid-2TMS (R.T. 22.043 min)

MRM

Scan/MRM Analysis of Metabolites in Rat UrineBlack: Total ion chromatogram (m/z: 45 to 600) Blue: 275 > 241; Red: 275 > 111

1 2

3

4,5

6

7

8

9

10

11

12 13

100 Transition 150 Transition 300 Transition 450 Transition 600 Transition

Glutaric acid-3TMS (R.T. 18.796 min)

Scan

9Gas Chromatograph Mass Spectrometer

Page 10: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

C17 C18 C19

1700 1735

1735

1800C17 C18 C19

1700 1800

Automatic adjustment

Identificationwindow

Analyte20 21 22

21.1min(Calculated RT)

21.5min(Originally registered RT)

The AART function adjusts the retention times of

target components based on linear retention indices

(LRI) and the retention times of n-alkanes. The AART

function easily adjusts retention times, even for

simultaneous MRM analysis of multiple components.

1 2AART execution 3Adjustment of retention times

Automatic Adjustment of Compound Retention Time (AART)(Automatic Adjustment of Retention Time)

Retention index

Retention index

Retention index

n-alkane analysis

Ultimate Ease of Use

Compatibility with GCMS-QP2010 Series Methods

Single GC/MS Methods and Libraries

The GCMS-TQ8030 can be used for single-quadrupole

GC/MS analysis, and existing single-quadrupole

methods are easily adapted to the TQ by simply adding

the additional MRM analysis parameters. The same

software platform is used for both types of instruments.

Originally registered method information

Customer's instrument

Adjustment covers many points, from low to high boiling points, so accurate adjustment is possible over a wide retention time range.

10

Page 11: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

The Easy sTop navigator assists in taking the appropriate steps.

When changing the ionization method or performing

maintenance on the area around the ion source, parts inside

the evacuation system must be handled.

The GCMS-TQ8030 uses a front-opening chamber in a

practical design, allowing maintenance to be performed with

ease from the front of the instrument. "MSNAVIGATOR,"

which supports maintenance, has been improved to help the

user perform instrument maintenance.

User Friendly

MSNAVIGATOR Window

Ion Source

The line of sight of a flat architecturemakes the filament difficult to see.

Easy sTop for Major Reduction of Maintenance Time

Many applications require that the injection port undergoes

maintenance on a frequent basis. With the GCMS-TQ8030,

maintenance is possible without venting the MS so

downtime is minimized.

Line of sight with this instrument

Pursuing a design withease of maintenancein mind.

10 min5 min 180 min

Maintenance

Maintenance

Maintenance start

10 min 15 min

Inlet cooling AnalysisInlet heating

Inlet heating

Time savings of 3 hours

Inlet cooling Vacuumstopped AnalysisVacuum startup,

Attainment of maximum vacuum level, Stabilization,

Conventionalprocedure

Easy sTop

11Gas Chromatograph Mass Spectrometer

Page 12: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

GCMSsolution Real-Time Analysis ProgramIn addition to scan and SIM modes, the GCMS-TQ8030

also offers a variety of other analysis modes, such as

MRM and scan/MRM.

The COAST (Creation of Automatic Scan/SIM Table)

function enables switching between measurement modes

or specifying time programs while checking data.

This makes it easy to set optimal analytical conditions that

are compatible with a variety of measurement modes.

GCMS Browser ProgramQuantitation BrowserThe quantitation browser allows the user to review

multiple data sets in the same window. This allows

checking the chromatograms and quantitation results

from multiple samples with minimal switching between

windows.

Extensive Report Creation FeaturesGCMSsolution software allows the user to design, edit,

and customize report formats to meet individual program

requirements.

Items to be included in reports can be pasted on a blank

report page, and size and position modified as needed.

Macro functions are also available to enable displaying

file names or other necessary information.

In addition, a generous selection of report templates is

available for various applications, so even first-time users

can output reports easily.

GC/MS analysis requires optimizing and managing many GC

and MS parameters for data acquisition. Furthermore, analyzing

the acquired data requires identifying unknown components

included in samples, quantitating more than a few hundred

components, and processing them quickly. GCMSsolution

software provides a user-friendly interface that allows

operating the system intuitively and includes Wizard functions

that assist in entering parameters, ensuring that even first-time

users can reliably navigate the system. "One-Window"

technology allows the user to customize the window layout for

individual methods or personal preference.

A single GCMSsolution software platform can be used to

analyze GCMS-TQ8030 and GCMS-QP2010 series data.

Workstation Software Combines Ease of Use and Versatile Functionality

G C M S s o l u t i o n

12

Page 13: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

O

O

Application Systems

In addition to commonly-used electron ionization (EI), both chemical

ionization (CI) and negative chemical ionization (NCI) are available.

CI is suited for confirmation of ionized molecular weight. NCI can be

used to detect functional groups having a large electron affinity such

as halogens. Any of three types of reagent gases (methane,

isobutane, or ammonia) can be used.

Structural information about compounds can be obtained by

performing scan and product ion scan measurements.

Chemical Ionization Method

Twin Line MS System Eliminates the Need to Swap Columns

The GCMS-TQ8030 is capable of accepting installation of

two narrow-bore capillary columns into the MS

simultaneously. This allows you to switch applications

without physically modifying the column installation.

Simply decide which column is best for your analysis and

choose the associated injection port.

Twin Line MS System

Analysis of pesticide components usingcomplementary column phases

Cl Analysis Results for Methyl Linolenate (Z) Left: Cl-scan; Right: CI product ion scan

Installing two columns in one MS is possible with the GCMS-TQ8030 because of its high-capacity dual-inlet turbomolecular pump.* The Twin Line MS System requires an optional installation kit and is limited to certain column dimensions.

Rxi-5Sil MS

Rtx-200MS

13Gas Chromatograph Mass Spectrometer

Page 14: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

Reduction of Annual Power Consumption

*) This is based on 6 hours of use per day for 260 days over the course of a year under our standard analytical conditions.

If Ecology mode is used over one year of operation*, power consumption can be reduced by 26% and CO2 emissions can be reduced by approx. 1.1 tons.

Saving Power Consumption with an “Ecology mode”for Reduced Instrument Running Costs

When Ecology mode is entered, unnecessary power consumption by the GC, MS, and PC is automatically eliminated. The consumption of carrier gas is also automatically reduced. Furthermore, Ecology mode can be entered automatically after continuous analysis, so power and carrier gas can be saved automatically after the completion of nighttime analysis.

Equipping the instrument with "Ecology mode" reduces the power consumed in analysis standby mode by 36%, compared with the previous model. In nighttime GC-MS operation Ecology mode can be set automatically, making it possible to reduce unnecessary power consumption.

There is increasing public interest in reducing running

costs and environmental stress. Reducing power

consumption is a common concern not only for the

reduction in a laboratory’s energy cost, but also as a way

to reduce CO2 emissions. In addition, helium carrier gas

is a non-renewable, valuable natural resource.

The GCMS-TQ8030 has eco-friendly features for saving

power and carrier gas.

Eco-Friendly Design for Lower Running Costs in the Laboratory

Reduces Power Consumption of Indoor Air Conditioning

Eco Friendly

The ecology mode reduces power consumption during

the analysis standby mode. Consequently,

it reduces heat output. The ecology mode not only saves

instrument energy, it also helps save on the energy

required to maintain the room temperature.

Ecology mode screen

This product is certified compliant with Shimadzu ECO-label standards. It consumes 36% less power than with the ecology mode switched OFF.

Reduction of Power Consumption inAnalysis Standby Mode

Standby inNormal (W)

760 W

Standby inEcology mode (W)

483 W

Ecology mode

5640 kWh

Pow

er C

onsu

mpt

ion

(W)

Pow

er C

onsu

mpt

ion

(kW

h)

•Reduction in power consumption by 26%

•Reduction in CO2

emissions by 1.1 tons

•Reduction by 36%

GC

GC

MS

PC

MS

Normal mode

7640 kWh

PC

14

Page 15: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

Analysis without Backflush (cabbage extract + standard)

Analysis with Backflush(cabbage extract + standard)

Cabbage extract

Blank run

Advanced Flow Technology (AFT) provides enhanced separation power

and operational efficiency for applications with complex sample matrices.

AFT enables reduced analysis times, enhanced chromatographic

resolution, and application-specific configurations without compromising

key performance features.

Capillary Gas Chromatography System

Advanced Flow Technology

• Heart-Cut System

• Backflush System

• Detector Splitting System

• Detector Switching System

• Multi-Deans’ Switching System

Separationcolumn

Backflush element

Restrictor

Analysis of Cabbage Extract Using a Backflush System

The backflush system reverses the carrier gas flow after the target compounds have eluted to discharge residual late eluting components in the column through the injection port split vent. Backflush shortens the analysis time and improves productivity. In addition, high-boiling point components are discharged efficiently to reduce the bake-out time (elution time), and thus prevent column deterioration, contamination, and retention time shifts. The example shown here illustrates how over 50 percent of analysis time can be reduced using backflush.

Analysis of Chlorine-Based Agricultural Chemicals in Cabbage

15Gas Chromatograph Mass Spectrometer

Page 16: GCMS-TQ8030 · GCMS-QP2010 Ultra LCMS-8030 LCMS-8040 LCMS-8080 LCMS-IT-TOF GCMS-QP2010 SE GCMS-TQ8030 LCMS-2020 PP. 6–7 Ultimate Ease of Use • AART function automatically adjusts

GC

MS-TQ

8030 

Printed in Japan 3655-06210-40ANS

Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.

For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.

© Shimadzu Corporation, 2012www.shimadzu.com/an/