GAS COMBUSTION GROUP - Systema · cio tecnico Systema S.p.A. (*) At full power in standard...
Transcript of GAS COMBUSTION GROUP - Systema · cio tecnico Systema S.p.A. (*) At full power in standard...
HEATING COOLING GREEN ENERGY
SYSTEMA S.p.A. Via Antonio Ceccon, 3 Loreggia (PD)C.A.P. 35010 - ITALIA - Tel. +39.049.9355663 r.a.
[email protected] - www.systema.it
CERTIFICATIONSþ CE certified.þ The equipments have been certified for the outdoor
installation with a global electrical protection degree IP 44þ In accordance with the Community Directive EMC 89/336/CEEþ In accordance with the Community Directive LOW VOLTAGE
73/23/CEEþ Low noise level according to the DIN-VDE-0530 regulations
CERTIFICAZIONIþ Certificazione CEþ Certificato per l’installazione all’esterno con grado protezione
elettrica globale IP 44þ Conforme alla Direttiva EMC 89/336/CEEþ Conforme alla Direttiva BASSA TENSIONE 73/23/CEEþ Basso livello di rumorosità secondo le norme DIN-VDE-0530
OHAGRUPPO DI COMBUSTIONE A GAS - GAS COMBUSTION GROUP
BREVETTATO - PATENTED
» 8 versioni, 3 modelli base» Camera combustione acciaio inox, garantita 10 anni» 8 livelli di potenza da 50 a 300 kW» Riscaldamento di grandi ambienti
UNITÀ TERMICA - COMBUSTION UNIT
» 8 versions, 3 standard models» Stainless steel combustion chamber, 10 years guarantee» 8 powers, from 50 to 300 kW» Perfect for the heating of large environments
CARATTERISTICHE TECNICHEUnità termica certificata CE, brevettata, pensile da installare all’esternocompleta di:» Bruciatore a gas ad alto rendimento, ventilatore per ricircolo ed
espulsione del fluido vettore termico» Quadro elettrico di comando a bordo macchina completo di apparec-
chiatura elettronica e sistemi di sicurezza, sonde rilevazione tempe-ratura e depressione
» Mantello di protezione con pannellatura autoportante in lamiera ver-niciata con materiale termoplastico
TECHNICAL FEATURESCombustion unit CE certified, patented, to be installed outdoor, equippedwith:» High efficiency gas burner with provided with fan for the recirculation
and the exhaust of the thermal fluid» Control panel on board, fitted with electronic control device and safety
systems, temperature probes and pressure detection» Protection body with self-supporting panels in iron plate, protected by
thermoplastic material
Isolante TermicoInsulation layer
Parabola riflettenteReflector
Fianchi LateraliSide panels
Tubi radiantiRadiant pipes
STRUTTURA DEL NASTRO RADIANTESTRUCTURE OF THE RADIANT CIRCUIT
(*) Alla massima potenza in condizioni normalizzate(**) Il modello RANGE RATED consente la taratura della potenza mas-
sima del bruciatore in base all’effettivo carico termico richiesto dalcircuito radiante.
(i) I valori indicati sono solo ed esclusivamente da intendersi come in-dicativi, dato che nella realtà tali valori variano in funzione di comeè stato costruito l’impianto e dal tipo di utilizzo dello stesso.
ATTENZIONE:Per il corretto dimensionamento dell’impianto contattare l’uffi-
cio tecnico Systema S.p.A.
(*) At full power in standard conditions(**) RANGE RATED version allows the calibration of the burner at full power
according with the real thermal load required by the radiant circuit.(i) The values indicated are exclusively indicative, considering that they
usually change according with the real design of the system and thefinal use.
ATTENZIONE:For a proper design of the heating system, please get in touch with
the Technical Department of Systema S.p.A.
MODELLO STANDARDSTANDARD MODEL OHA100 OHA200 OHA400
VERSIONEVERSION
OHA100-50
OHA100-100
OHA200-115
OHA200-150
OHA200-180
OHA400-200
OHA400-250
OHA400-300
Portata termicaThermal capacity
kW (Hi) 50 100 115 150 180 200 250 300
Potenza termicaThermal power
kW (Hi) 45,5 93,0 105,2 138,0 165,6 183,0 230,0 276,0
Rendimento di combustione *Combustion performance *
% 90,6 90,8 91,5 88 91 88 88,1 91,3
Consumo nominale a 15°C e1013,25 mbarRated CONSUMPTION at 15°C and1013,25 mbar
G20 Nm3/h 5,29 10,58 12,17 15,87 19,05 21,16 26,46 31,75
G31 kg/h 3,88 7,77 8,93 11,65 13,98 15,54 19,42 23,31
Alimentazione elettricaElectric power supply
3/N/PE ~ 50Hz 400V
Potenza elettrica max assorbitaMax electric power absorbed
W 1350 3450 4450 4450 5700
Connessione attacco gas (maschio)Gas connection (male)
PolliciInc.
1” 1” 1” 1”
Peso apparecchioEquipment weight
kg 90 230 240 240 260
Diametro condotto fumiFume pipe diameter
mm 200 200 200
Lunghezza max condotto scarico fumiMax length of fume exhaust pipe
m 6 6 6 9
Tipo apparecchioEquipment type
B22 B22 B22
Dimensione [mm]Dimension [mm]
A** 1075 (1095) N (*) 1142B 359 O 740C 200 P (*) 343D 664 Q 142E 333 R 637F 774 S 426G 157 T 162H 134 U 300I 398 V 344L 333 X 1049M 333 Y 1202
(*) Nel caso di unità con plenumlungo (fornito solo su ordinazione)le quote N e P sonorispettivamente 1802 e 1003 mm(*) In case of long plenum (onlysupplied if specifically required) thedimensions N and P are respectively1802 and 1003 mm)(**) Oha Standard= 1075Oha RHE= 1095
DIMENSIONI UNITÀ DI COMBUSTIONE DIMENSIONS HEATING UNIT
DIMENSIONI NASTRO RADIANTE
1 tubo - 1 pipeStandard
2 tubi - 2 pipesStandard
2 tubi - 2 pipesPreassemblato - Preassembled
Dimensione Nastro Radiante StandardDimensions of the Standard Radiant circuit
Quota - Height 1 tubo - 1 pipe 2 tubi - 2 pipesA Ø mm Ø300 Ø 300B mm - 335C mm 512 850D mm 580 918E mm 374 374F mm - -G mm - -
Peso - Weight kg/m 19 28
Dimensione Nastro Radiante preassemblatoDimensions of the Preassembled Radiant circuit
Quota - Height 2 tubi - 2 pipesA Ø mm Ø 300B mm 335C mm 850D mm 930E mm 396F mm 421G mm 6000
Peso - Weight kg/m 28
DIMENSIONS OF THE RADIANT CIRCUIT