Gas analysis / Temperature / Pressure€¦ · efficient analysis Page 04 KIGAZ Combustion gas...
Transcript of Gas analysis / Temperature / Pressure€¦ · efficient analysis Page 04 KIGAZ Combustion gas...
02
easy analysis
efficient analysis
Page 04
KIGAZ Combustion gas analysers
Page 05
Optimum efficiencyto reduce pollutant emissions
15 combustiblesprogrammed
Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5%, Wood 20%, Wood-chip 21%, Pellet 8%
KiGaZ 150 KiGaZ 100
Ergonomics and technologydedicated to your job.
O2 / cO-H2 / cH4 / nO / nO2 / sO2
Up to
Summary
neW PRODUct
2 sensors
interchangeable2
sensorsinterchangeable
4 sensors
interchangeable
EN50379
TÜV-SÜD ApprovedEN50379 - 1&2
(§5.5 / §5.6 / §5.7)
03
cUstOm analysis smaRt analysis
liGaZ / lOGaZ Softwares for measurement assistance
KiGaZRefeRences
Accessories andexternal probes
KIGAZ Combustion gas analysers
Page 08
Page 10
Page 1 1
Page 06
A maximum efficiency and the safety of installation are the key points to guarantee an efficient and controled combustion.combustibles
SOLUTIONfOr Any tyPE Of bOilErS
KiGaZ 200 KiGaZ 300
We have developed a new range of combustion gas analysers, which fulfil all needs of heating professionals. Our analysers are scalable and offer many solutions for any type of boilers, to control pollutant emissions.
QUality: All kiGAz instruments are supplied with a certificate kiGAz 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . adjustment certificatekiGAz 100 | 200 | 300 . . . . . . . . . . . . . . . . . . . . calibration certificate
BluetoothTM
Communication
Protectionof sensors
Up to Up to3 sensors
interchangeable4
sensorsinterchangeable
SOLUTIONtHE bASE SOlUtiOn24 cm
Menus and example of analysis
External printer - option (p.11)
the KiGaZ 150 model is compact and light, it is perfectly suitable to the study of the main check points of any type of boilers.
Parameters sensors measuring range
O2 Electro-chemical 0 to 21 %CO (with H2 compensation) Electro-chemical 0 to 8000 ppmFlue gas temperature K Thermocouple -100 to +1250°CAmbient temperature NTC -20 to +120°CAmbient temperature Pt100 -50 to +250°CPressure draft Semiconductor ±200 hPaEfficiency (condensing) Calculated* 0 to 120 %
* Calculation is based on the values measured by the analyser
Combustion gas analyser
KIGAZ 150
KiGaZ 150 and 100
180 mm flue gas probe
04
Protection of sensors by pump stopping
Easy analysis
1 input for external probe
common features KiGaZ 150 and KiGaZ 100
1 thermocoupleinput
supplied with
aDjUstment
certificate
Autodiagnosticmenu
2 Go memory
Protective cover with magnet for KIGAZ 150
tHeRmalPaPeR
10-yearguarantee
- Autodiagnostic menu
- 100 000 measurements
- Reports printing
- Efficiency up to 120 %
- Simultaneous display of measurements
- Battery life: 10h in continuous operation
- External probe (option)
interchangeableO2 / cO-H2 sensors
Protective coverwith magnet
Combustion gas analyser
KIGAZ 100
Display of 12 measurements
Autodiagnosticmenu
2 Go memory
the KiGaZ 100 is the key tool for a fast check of any type of boilers. Easy to use and light, it allows the study of the main check points.
Singleconnector
1 thermocouple input1 input for external probe
DHW network (external tcK probe)
from -20 to +90°C
Printer KiGaZ 150 � � � � � � � � � external (option)KiGaZ 100 � � � � � � � � � � � � � � integrated
05
Integrated printer
Efficient analysis
180 mm gas flue probe
tHeRmalPaPeR
10-yearguarantee
supplied withcalibRatiOn certificate
Protective cover with magnet for KIGAZ 100
2 sensors
interchangeable
supplied with: transport bag liGAZ softwareAdjustment certificate (KiGAZ 150)Calibration certificate (KiGAZ 100)Protective cover with magnet
06
* Calculation is based on the values measured by the analyser
LED
Interchangeable probe 300 mm
Rotatingbutton With its large display, and its icon browsing system, the
KiGaZ 200 simplifies your measurement process. Scalable and accurate, it offers many type of measurements that you can configure according to your needs.
characteristics
- Interchangeable probe
- Customized procedure
- Up to 12 measurements displayed simultaneously (choice of 3, 6, 12)
- LED on probe handle to light dark areas
O2 Electro-chemical 0 to 21 %CO (H2 compensation) Electro-chemical 0 to 8000 ppmFlue gas temperature K Thermocouple -100 to +1250°CAmbient temperature NTC -20 to +120°CAmbient temperature Pt100 -50 to +250°C
Draft pressure Semiconductor ±200 hPaLosses Calculated* 0 to 100 %Flue gas velocity Calculated* 0 to 99,9 m/sExcess air Calculated* 1 to 999 %Efficiency (condensation) Calculated* 0 to 120 %
Parameters sensors measuring range Parameters sensors measuring range
1 input for external
probe
interchangeableO2 / cO-H2 / nO / cH4
sensors
Autozero in the flue
integrated printer
Combustion gas analyser
KIGAZ 200
reports printing
3.5"display
Custom analysis
KiGaZ 200
supplied with: transport bag liGAZ softwareCalibration certificate Protective cover with magnet
Protective cover with magnet
supplied withcalibRatiOn certificate
Up to 3 sensors
interchangeable
tHeRmalPaPeR
10-yearguarantee
07
Procedure menu allowsa step-by-step assistance
connections
Gas network kit
Verification of DHW network Domestic Hot WaterUse special velcro and piping probes
Gas network verification
cO controlOther remote probes on page 11.
Verification of ionisation current Multimeter function
CO sensor protection by solenoid valve
ApplicationsAdditional
Flue gas connection
P+ pressure plugP-Thermocoupleconnections
top view bottom view
External probe connection(Pt100 temperature, CH4 ...)
Front view Rear view
Protective cover with magnet
smArtGRAPhICM E N U
08
the KiGaZ 300 is the most comprehensive instrument of the range. it can be customized and can be adapted to any specific dataset. you save time and you improve your work conditions, thanks to its vocal support and to the lighting lED for dark rooms.
Parameters sensors measuring range
O2 Electro-chemical 0 to 21 %CO (H2 compensation) Electro-chemical 0 to 8000 ppmFlue gas temperature K Thermocouple -100 to +1250°CAmbient temperature NTC -20 to +120°CAmbient temperature Pt100 (external probe) -50 to +250°CDew point temperature Calculated* 0 to 99°CtdDraft Piezoelectric ±1000 PaDifferential pressure Piezoelectric ±200 mbar
Parameters sensors measuring range
Losses Calculated* 0 to 100 %Flue gas velocity Calculated* 0 to 99,9 m/sExcess air Calculated* 1 to 999 %Efficiency (condensation) Calculated* 0 to 120 %Opacity index External instrument 0 to 9Dilution Electro-chemical 0,8 to 5 %CH4 Semiconductor 0 to 10 000 ppmT DHW TcK (external probe) -20 to +90°C
O2 / cO-H2 / cH4 / nO / nO2 / sO2sensors
in standard or option
CO Dilution
Autozero in the flue
Vocal Help
Integrated Water trap
Any typeof boilers
5%
Combustion gas analyser
KIGAZ 300
Smart analysis
- Customized procedures
- CO dilution
- Simplified water discharge
- Optional: probe up to 1000°C
features
supplied withcalibRatiOn certificate
* Calculation is based on the values measured by the analyser
Up to 4 sensors
interchangeable
smArtGRAPhICM E N U
09
300 mminterchangeable flue gas probe
Water trap discharge
TFT 3.5" color screen
Max level Alarm
LED
Single connector
Water trap
All our datasheetsavailable on www.kimo.fr/gas
Differential pressure measurement
High accuracy draft measurement with autozero by solenoid valve
Measurement of the suction pump flow
3sensors
pressure
Printing of maintenance certificate of the instrument
integrated printer
Memory 2 Go
Pressure
DHW network Measuring of ambient CO
Protective magnetic cover
2 thermocouple inputs 1 input for external probe Ambient CO / Gas leak / Temperature
Filter location
CO dilution
supplied with: transport case liGAZ softwareCalibration certificate Protective cover with magnet
tHeRmalPaPeR
10-yearguarantee
COnfiGUrE yOUr AnAlySErConnect the kiGAz via USB or BluetoothTM connection.
DAtAbASE MAnAGEMEntRecord your customers, boilers and measurements records.
PrintinGDownload your datasets and the programme will automatically fill in the measurement report.
rEPOrtSEasy reading of measurement reports. Customize, print and export your files.
CHECK SCHEDUlEOrganize your agenda, maintenance contracts, clients follow-up.
OnlinE MODEDisplay and recording of measurements in real-time.
BluetoothTM
Communication
LIGAZSupplied in standard with all KiGaZ
LOGAZOptional software for KiGaZ 200 / 300 models
Configure
Schedule
Control
Process
Software
LIGAZ | LOGAZ
KIMO simplifiesyour daily life
Professional | solutions ASSiSTANCE FOR MEASUREMENT
MyLOGO
10
legend: Standard • Option - not availableKIGAZ 150 | 100 | 200 | 300
External probes additional measures
References Description 150 100 200stD 200PRO 300cla 300stD 300PRO
interchangeable sensors CI-O2 O
2 from 0 to 21 %
CI-COH2 CO-H2 from 0 to 8000 ppm
CI-NO NO from 0 to 5000 ppm - - • • CI-NO2 NO
2 from 0 to 1000 ppm - - - - • •
CI-SO2 SO2 from 0 to 5000 ppm - - - - • •
CI-CH4 CH4 for gas detection from 0 to 10 000 ppm - - • • • • •
Flue gas probesPSK-180 L 180 mm up to 500°C • • • • •PSK-300 L 300 mm up to 500°C - - PSK-750 L 750 mm / inconel up to 1000°C - - • • • • •PSF-1 Flue gas probe with handle, 6m cable, water trap - • - - - - -PSF-2 Flue gas probe with handle, 6m cable, water trap - - • • - - -PSF-3 Flue gas probe with handle, 6m cable, water trap - - - - • • •SF6-15 Fixed flue gas probe with handle, 6m cable, water trap • - - - - - -
AccessoriesKDIP External printer • - - - - - -KEG Gas network tightness kit • • • • • • •PMO Opacity pump • • • • • • •MAK Aluminium transport case • • • • • • •MABS ABS transport case • • • • MB-123 BluetoothtM module • • • • • • •LOGAZ Exploitation software - - • • • • •
or
SCIIonisation current measurement probe
SDFGGas leak detection probe (CH
4)
SCOTAmbient CO probe
SCO2TAmbient CO
2 probe
SPA 150 SPAmbient Pt100 probe
SKCL 150Thermocouple probe with lamella
SKV 150Velcro thermocouple K probe for ducts
SKCTThermocouple probewith lamella contact and springfor pipes
Products
REfERENCES
SMART+ Probes
11
RCS
(24)
Périg
ueux
349
282
095
- D
ocum
ent n
on c
ontra
ctue
l - N
ous
nous
rése
rvon
s la
pos
sibi
lité
de fa
ire é
volu
er le
s ca
ract
éris
tique
s de
nos
pro
duits
san
s pr
éavi
sDo
c An
alys
eurs
de
Com
bust
ion
- V1
- Ang
lais
- 0
6/12
www.kimo.fr
KIMO - Export DepartmentBoulevard de Beaubourg - BP 48Emerainville - F-77312 MARNE LA VALLEE Cedex 2 - FranceTel.: +33 1 60 06 69 25 - Fax: +33 1 60 06 69 29Email: [email protected]
Distributed by: