Transcript of g Speed Es Manual Mac 11-18-07
G-SPEED eS INSTALLATION GUIDE
Page 1
G-SPEED™ eS Mac Installation Guide
G-Technology Inc. Tel: (310) 449-4599 Fax: (310) 449-4670
P/N GSPEED eS v1.2
TABLE OF CONTENTS
1. INTRODUCTION (Pg 4)
2. SAFETY PRECAUTIONS
3. SYSTEM REQUIREMENTS
4. WHAT’S IN THE BOX
5. G-SPEED eS OVERVIEW (Pg 5)
6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW 7. G-SPEED eS AUDIBLE ALARMS (Pg 6)
8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID
CONTROLLER
9. G-TECH RAID CONTROLLER WEB GUI (Pg 8)
10. CHANGING THE G-TECH RAID CONTROLLER MODE (Pg 9)
11. CONFIGURING TWO G-SPEED eS UNITS IN RAID 5 MODE (Pg 11)
12. WHAT TO DO IN THE EVENT OF A DISK DRIVE FAILURE (Pg 15)
13. TECHNICAL SUPPORT (Pg 17)
14. LIMITED WARRANTY
APPENDIX A – DETAILED INFORMATION ON USING THE WEB GUI APPENDIX B – EXPLANATION OF RAID LEVELS APPENDIX C – NOTES
G-SPEED eS INSTALLATION GUIDE
Page 2
G-SPEED eS INSTALLATION GUIDE
Page 3
G-SPEED eS INSTALLATION GUIDE
Page 4
1. INTRODUCTION Thank you for purchasing G-SPEED eS from G-Technology, Inc. (G-Tech)! Specifically designed for professional content creation applications, G-SPEED eS features a high-speed 3Gbit/sec eSATA interface and provides RAID 0, 1, 5, 10 and JBOD functionality when used in conjunction with the optional G-Tech PCI Express (PCIe) RAID controller. Up to four G-SPEED eS units can be attached to the G-Tech RAID controller for storage capacities to 16 TB and data rates over 600 MB/sec. G-SPEED eS supports multi-stream video editing workflows on Mac Pro workstations.
If you purchased G-SPEED eS with the G-Tech PCIe RAID controller, the system has been set up at the factory in RAID 0 mode. The controller also supports RAID 1, 5, 10 and JBOD modes. Refer to Section XX if you wish to change the mode of operation.
2. SAFETY PRECAUTIONS
The disk drives contained in your G-SPEED eS are delicate electronic instruments and are susceptible to damage due to excessive physical shock. Place the unit in a vented area away from moisture or liquids. Please handle the unit with care. Do not open the case. Doing so will void the warranty. If the Product is returned with damage caused by improper handling, the warranty will be void and liability will rest with the user.
3. SYSTEM REQUIREMENTS
• Apple Mac Pro (Intel Mac) workstation • Mac OS X 10.4.x or higher • G-Tech PCIe RAID Controller or third party port multiplier
aware eSATA host adapter
Optional G-Tech 4-port, PCIe x4 RAID Controller
4. WHAT’S IN THE BOX Take a moment to ensure that the following items are included in the box. If anything is missing, please call G-Tech at (310) 449-4599. Please keep the shipping container and packing materials. In the unlikely event that you need to return G-SPEED eS to us for any reason, you must use the G-Tech shipping container. If the Product is returned damaged caused by improper packaging, the warranty will be void and liability will rest with the user.
• G-SPEED eS storage system • 4 removable SATA drive modules (installed in unit) • (2) disk module keys • 1-meter eSATA cable • AC Power cable • Optional – G-Tech PCIe RAID controller • Configuration Utility & Installation CD
G-SPEED eS INSTALLATION GUIDE
Page 5
5. G-SPEED eS OVERVIEW
6. OPTIONAL G-TECH PCIe RAID CONTOLLER OVERVIEW
The optional G-Tech PCIe RAID controller connects G-SPEED eS to any Mac Pro workstation and provides RAID 0, 1, 5, 10 & JBOD functionality.
6.1 Supported RAID Levels If your G-SPEED eS shipped with the optional G-Tech PCIe RAID controller, the system was configured as a RAID 0 at the factory. The controller also supports RAID 1, 5, 10 and JBOD configurations. If you wish to change the RAID mode, please refer to Section 10.
For an explanation of supported RAID levels, please refer to Appendix B.
If you purchased G-SPEED eS with the G-Tech PCIe RAID controller, the system has been set up at the factory in RAID 0 mode. The controller also supports RAID 1, 5, 10 and JBOD modes. Refer to Section 10 if you wish to change the mode of operation.
G-SPEED eS is also compatible with third-party Mac & Windows port multiplier aware eSATA host adapters. Refer to your host adapter documentation to set up G-SPEED eS with these boards.
PCIe x4 interface RAID Engine
(4) High-speed 3 Gb/s eSATA ports. Supports up to (4) G-SPEED eS systems
(4) Removable Disk Drive Modules
Drive Module Power/Activity
LED
Temperature/Fan RPM Warning LED
Power Supply LED
Disk Module Lock Hole
ON/ OFF Switch
Removable Fan
AC Input
3 GB/sec eSATA Port
Cable Lock Hole
G-SPEED eS INSTALLATION GUIDE
Page 6
7. G-SPEED eS AUDIBLE ALARMS 7.1 The G-SPEED eS enclosure is equipped with an audible
alarm that sounds when:
1. The internal temperature of the G-SPEED eS enclosure reaches a temperature of 60° centigrade
and/or
2. When the main FAN fails or the RPM of the fan slows to a state where the fan can longer adequately cool the system.
In addition to the audible alarm, the Temperature/Fan Warning LED located on the front bezel of G-SPEED eS will illuminate.
If you hear an audible alarm and see the RED warning LED on the front of G-SPEED eS, stop using G-SPEED eS immediately. Check to see if the fan is spinning and move the unit to a cooler location. If you require a new fan, contact G-Tech Support for a replacement.
7.2 The G-Tech RAID controller is also equipped with an
audible alarm that sounds when:
1. A disk drive failure occurs
or
2. When the G-SPEED eS is removed from the RAID controller without first selecting “Unplug” in the Array Maintenance menu in the web GUI.
If you hear an audible alarm coming from the G-Tech RAID controller, see Section 12 “What to do in the Event of a Disk Drive Failure”. See Appendix A.1.7.2 for information on the proper way to hot “Unplug” G-SPEED eS.
8. SETTING UP G-SPEED eS WITH THE G-TECH PCIe RAID CONTROLLER G-SPEED eS comes pre-configured in RAID 0 mode and formatted for MAC OS X. Connecting G-SPEED to your Mac Pro and configuring your system takes just a few steps as outlined below.
8.1 Installing the G-Tech PCIe RAID Controller
1. Install the G-Tech RAID controller into SLOT 4 (top slot) of your Mac Pro workstation.
2. Secure the RAID controller in place.
NOTE: If you are using an AJA, Blackmagic Design or equivalent video capture card, install it in SLOT 3 unless otherwise instructed by the card vendor.
G-Tech PCIe RAID Controller
G-SPE
8.2 1.
2.
3.
4.
8.3 1.
EED eS INSTA
Attaching G-SAttach one enport located o
Attach the othport) on the G
Attach the poconnect the o
Power on G-S
Loading the GDouble-click o“Manuals-Drivbelow.
ALLATION G
SPEED eS to tnd of the supplion the back of G
her end of the G-Tech RAID co
ower cord to theother end to AC
SPEED eS.
G-Tech PCIe Ron the G-SPEEDvers” folder on
UIDE
he G-TECH RAied eSATA cableG-SPEED eS.
eSATA cable toontroller as sho
e back of G-SPEC power.
RAID ControlleD eS icon locate the included C
AID Controllere to the eSATA
Port 1 (leftmown below.
EED eS and
er Software ed in the D as shown
r
st
2
3
2. Double-clickpackage as
Check fohttp://wIf you apreviou
3. The followininstructions
After restartmount on yo
Your G-Smode. Th10 and JB
change the mo
k on the “G-Tec shown below.
or software updatewww.g-technology.are upgrading sous version first. S
ng window will a to load the sof
ting your systeour desktop.
SPEED eS is shipphe G-Tech RAID coBOD modes. Refer ode of operation.
h RAID Control
es at com/Support/
oftware you mustSee section 8.4 fo
appear. Follow ftware.
m, the G-SPEE
ped from the factontroller also suppto Section 10 below
Pag
ller” installer
t un-install the or details
the
D eS will
tory in RAID 0 orts RAID 1, 5, w if you wish to
ge 7
G-SPE
8.4
1.
2.
9. G-TEThmoaneq
9.1
1.
2.
EED eS INSTA
Uninstalling t
Double-click o“Manuals-Drivabove. A Terminal wienter your paGUI.
ECH RAID CONhe G-Tech RAIDonitor the G-SP
ny web browserquivalent.
Accessing the
Open your we https:// The followingbutton.
NOTE: A shortc“G-SPEED eS WSPEED eS\Shortfile from the Doicon to access t
ALLATION G
the G-Tech PC
on the uninstalvers” folder on
ndow will openassword to dele
NTROLLER WED controller webPEED eS systemr such as Safari
e G-Tech PCIe
eb browser and
/localhost:740
g window will
cut has been providWeb GUI” file (locate
tcut to Web GUI) tocuments folder to he web GUI.
UIDE
CIe RAID Cont
l.command file the included C
n and you may te the installed
EB GUI b GUI is used tom. The GUI is ai, Internet Expl
e RAID Contro
d enter the follo
02
appear. Click t
ded to access the wed in the folder Mato your Documents the dock as shown
troller Softwa
located in the D as shown
be prompted tod driver and we
o configure andaccessed using orer or
oller Web GUI
owing address:
the <Continue
web GUI. Drag the anuals-Drivers\G- folder. Drag the
n below. Click on th
are
o b
d
I
>
he
3
3. The followinEnter “admzeros) as thbutton.
Notchan
ng will appear inin” as the User
he Password and
te: See appendix Anging the password
n your browserr Name and “00d click on the <
A.4.5 for instructiod
Pag
r window. 000” (four <Login>
ons on
ge 8
G-SPE
4.
EED eS INSTA
The main screbelow. Note tEach of the folower Section
NOTE: Pleasefeatures of th
ALLATION G
een of the web hat the G-SPEEour drives in thn of the GUI.
e refer to APPENDIhe G-Tech RAID Co
UIDE
GUI will appeaED eS is set up e unit are displ
IX A for detailed infontroller web GUI.
ar as shown as a RAID 0. ayed in the
formation on the
10. C
TcJcc
10.
1
2
3
CHANGING TH
The G-SPEED econfigured at thJBOD modes archange the modchange modes. .1 Changing fr
1. Unmount G-S
2. Launch the G
3. Click on the “will appear.
HE G-TECH RA
S/G-Tech RAIDhe factory in RAre also availablede of operation
rom RAID 0 to
SPEED eS by d
G-Tech RAID Co
“Maintenance”
ID CONTOLLE
D controller comAID 0 mode. Re. The web GUI. Follow the di
o RAID 5
ragging the ico
ontroller web G
Link. The wind
Pag
ER MODE
mbination is RAID 1, 5, 10 anI is used to irections below
on to the trash.
UI.
dow shown belo
ge 9
nd
to
ow
G-SPE
4.
5.
6.
EED eS INSTA
Click on the <will appear. C
W
st
The GUI will r
Click the <Cwindow will a
ALLATION G
<DELETE> buttClick the <OK>
WARNING: This wilored on G-SPEED e
refresh and the
Create Array> ppear.
UIDE
ton. The followi button to proce
l delete any data eS!
e array is now d
button. The
ng window eed.
deleted.
“Create Arrayy”
7
7. Select RAIDfor “Array Nfor “Initializrespectively
NOTE: Incan also bappropria
D 5 for “Array Tame:”, select Fation Method:”
y and click the <
n this example we abe set up in RAID 1te setting in the “A
Type:”, enter G-Foreground an” and “Cache Po<Select All> bu
are creating a RAID1, 10 or JBOD modArray Type:” pull-d
Page
-SPEEDeS-R5nd Write Backolicy:” utton.
D 5. The system e by selecting the own menu.
e 10
k
G-SPE
8. C
9. C
T
10. T
pc“
EED eS INSTA
Click the <Crea
Click the <OK>The GUI will ind
The RAID 5 initper TB of final ccomplete, the G“Status” as Nor
ALLATION G
ate> button. Th
> button. The fdicate that the
tialization procecapacity. OnceGUI will indicatermal .
UIDE
he following win
following windoG-SPEED eS is
ess takes approe the initializatioe “Type” as RA
ndow will appea
ow will appear. initializing.
oximately 1:45 on process is
AID 5 and
ar.
1
11. C
EGJccG
1. The Mac OS
indicating tClick on theUtility and instructions
CONFIGURING
Each G-SPEED G-Tech RAID coJBOD modes archange the modconfigure two GG-Tech RAID co
1. Ensure tha
installed an
2. Attach bothcontroller ayour compu
3. Both system
S will display ththe G-SPEED eSe <Initialize> brefer to your sys.
G TWO G-SPEE
eS unit is confiontroller in RAIDre also availablede of operationG-SPEED eS arrontroller.
t the G-Tech RAnd the driver an
h G-SPEED eS uas shown belowuter
ms will mount o
he “Disk InsertiS is now ready button to launcystem documen
ED eS UNITS I
gured at the faD 0 mode. RAIe. The web GUI
n. Follow the dirays in RAID 5
AID controller ind web GUI are
units to the G-Tw, power the un
on the desktop
Page
ion” window to be initializedh the Apple Disntation for
IN RAID 5 MO
actory with the ID 1, 5, 10 andI is used to irections below mode using the
s properly e loaded.
Tech RAID nits and restart
.
e 11
d. sk
ODE
d
to e
G-SPE
4. Ut
5. Lud
EED eS INSTA
Unmount both the trash. Launch the G-Tunits attached tdisplay informa
ALLATION G
G-SPEED eS un
Tech RAID Contto the G-Tech R
ation like that s
UIDE
nits by dragging
roller web GUI.RAID controller,hown below.
g the icons to
. With the two , the GUI will
6.
7.
Click on the “Name” GS Dis
Click the <Dewill appear.
WAsto
Maintenance” lsk 1_0. The wi
elete> button.
ARNING: This will red on G-SPEED eS
ink next to the indow shown b
The following w
delete any data S.
Page
array with “OSelow will appea
window
e 12
S ar.
G-SPE
8.
9.
10.
EED eS INSTA
Click the <OK
Click on the “Name” GS Dis
Click the <Deappear.
WA
sto
ALLATION G
K> button to de
Maintenance” lsk 1_1. The w
elete> button
ARNING: This willored on G-SPEED e
UIDE
elete the array.
ink next to theindow below w
and the follow
delete any data eS.
e array with “OSill appear.
wing window w
S
ill
11
12
1. Click the <arrays hav
2. Click the <Cwindow will
<OK> button e now been
Create Array> b appear.
to delete the deleted as s
button. The “C
Page
array. Both shown below.
Create Array”
e 13
G-SPE
13.
EED eS INSTA
Select RAID R5 for “ArrayBack for “Initrespectively aClick the <Cre
ALLATION G
5 for “Array Ty Name:”, selecttialization Methand click the <Seate> button.
UIDE
pe:”, enter G-St Foreground
hod:” and “CachSelect All> butt
SPEED-eS- and Write he Policy:” ton then
14
15
4. The followin
5. Click the <O
to indicate t
ng window will a
OK> button. Ththat the G-SPEE
appear.
he following wiED eS is initializ
Page
ndow will appezing.
e 14
ar
G-SPE
15.
16.
12. WHTheafaire
Fo
1
2
EED eS INSTA
The RAID 5 inper TB of finacomplete, the“Status” as N The Mac OS windicating theClick on the <Utility and refinstructions.
HAT TO DO INhe G-Tech RAIDach of the disk dilure, an audiblport the failed
NOTE: RAID mresult inunprotereplaced
ollow the steps
1. Launch the
2. Mute the alabutton.
ALLATION G
nitialization proal capacity. Once GUI will indica
Normal.
will display the e G-SPEED eS is<Initialize> butfer to your syst
THE EVENT O controller contdrives in G-SPEe alarm will soudrive and its ph
If G-SPEED eS wasode (RAID 1, 5 or
n data loss. Howevcted state and the d as soon as possib
below to identi
web GUI.
arm by clicking
UIDE
ocess takes appce the initializaate “Type” as R
“Disk Insertions now ready to tton to launch ttem documenta
OF A DISK DRItinually monitoEED eS. In the und. The web hysical position
s configured in a pr10), a drive failure
ver, the array is no failed drive shouldble to avoid data lo
fy and replace
g on the <Beepe
proximately 1:4tion process is
RAID 5 and
n” window be initialized. the Apple Disk ation for
IVE FAILURE rs the health of event of a diskGUI will also
n.
rotected e does not ow in an d be oss.
a failed drive.
er Mute>
45
f k
The GUI will dexclamation mthe “Status” othe GUI indicahas failed.
In tconthe RAI
display informamark on the G-of the array is Cates which driv
this example there nected to the G-Te G-SPEED eS conneD controller has fa
tion like that shSPEED eS icon Critical. The loe in which G-S
are two G-SPEED ech RAID controllerected to Port 2 of t
ailed.
Page
hown below. An indicates that wer portion of PEED eS unit
eS units r. Drive 3 of the G-Tech
e 15
n
G-SPE
3
EED eS INSTA
3. Remove theG-SPEED eScontroller) bhole and geenclosure.
WARdrive connefollowconne
X
ALLATION G
e failed drive (IS connected to by inserting theently sliding the
RNING: Make absol indicated by the Gected to the G-Techw the cable to ensuected to on the RAI
UIDE
n this example port 2 of the Ge provided key e drive module
lutely sure that youGUI. If multiple G-Sh RAID controller, re you know whichID controller.
Drive 3, of theG-Tech RAID in to the lock out of the
u remove the failedSPEED eS units areit is a good idea to
h Port # the array i
e
d e o is
R
LS
4. Replace th
secure in the GUI w“Status” scomplete)approxima
5. Once the r
Normal a
REMOVING THE WLOSS OF THE ARRSTORED ON G-SPE
he failed drive wplace. Once th
will indicate thathows Rebuildi as shown beloately 2 hours pe
rebuild is compnd protecting y
WRONG DRIVE WIRAY AND ALL OF TEED eS.
with a new diskhe drive has sput the array is reing and the peow. The rebuilder TB.
plete, G-SPEED your valuable d
Page
ILL RESULT IN TTHE CONTENT
k module and un up to speed,ebuilding (The rcentage d time is
eS is back to ata once again
e 16
HE
,
.
G-SPEED eS INSTALLATION GUIDE
Page 17
13. TECHNICAL SUPPORT If you encounter any difficulties while installing G-SPEED, please contact G-Tech Technical Support via one of the following ways:
Telephone: (310) 449-4599 Fax: (310) 449-4670 E-mail: [email protected] Internet: http://www.g-technology.com/support
When contacting Technical Support, make sure to be in front of your computer and have the following information readily available:
• Your G-SPEED eS serial number (on bottom of unit) • Operating system and version • Computer brand and model • eSATA host adapter brand and model • Amount of memory installed • Other devices attached to your computer
Thank you for purchasing G-SPEED eS. If you have any comments or questions about this manual or the Product, please call (310) 449-4599, or send an email to [email protected].
14. LIMITED WARRANTY G-Technology Inc. (G-Tech) warrants your Product against any defect in material and workmanship, under normal use, for the designated warranty period. If the Product should become defective within the warranty period, G-Tech, will at its discretion, repair or replace the Product. Repair or replacement parts or Products will be furnished on an exchange basis and will be either new or reconditioned. All replaced parts or Products shall become the Property of G-Tech. This warranty shall not apply if the Product has been damaged by accident, misuse, abuse or as a result of unauthorized service or parts. Warranty service is available to the purchaser by obtaining a Return Material Authorization number (RMA) and by delivering the Product during the warranty period to an authorized G-Tech service facility or to G-Tech. The purchaser shall bear all shipping, packing and insurance costs and all other costs, excluding parts and labor, necessary to effectuate repair, replacement or refund under this warranty. All returned Product must be shipped to G-Tech in the original shipping container.
For more information on how to obtain warranty service, an RMA number or to acquire shipping materials, contact G-Tech at 1653 Stanford Street, Santa Monica, CA 90404, (310) 449-4599 or [email protected]. IN THE EVENT A PRODUCT BECOMES DEFECTIVE DURING THE WARRANTY PERIOD, THE PURCHASER’S EXCLUSIVE REMEDY SHALL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE. INCIDENTAL OR CONSEPROUENTAL DAMAGES, INCLUDING WITHOUT LIMITATION LOSS OF DATA, ARISING FROM BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ARE NOT THE RESPONSIBILITY OF G-TECH AND, TO THE EXTENT PERMITTED BY LAW, ARE HEREBY EXCLUDED BOTH FOR PROPERTY DAMAGE, AND TO THE EXTENT NOT UNCONSCIONABLE, FOR PERSONAL INJURY DAMAGE.
G-SPE
APPE
1
2
3
4
5
6
EED eS INSTA
ENDIX A: WEB
1. Manage: Array: Thisweb GUI. Gfrom this paDevices: Hpage (you page as tperformancSpare Poodrives can bcalled hot sadded to th
2. Events: Allrecorded heThese evennotification
3. Tasks: Schautomaticalvolume.
4. Settings: settings snotification.
5. Drive Stathard drives
6. Logout: Sa
ALLATION G
B GUI
s is the main G-SPEED eS is age. (See Appe
Hard drive paramshould not m
the drives aree with the G-SP
ol: When confbe assigned to spare). These de Array in the e
events of the ere, such as ants can be em under the “Set
edule the G-Tely verify the int
Configure theuch as logi. See Appendix
tus: Check th including detai
ay goodbye
UIDE
screen of the configured anendix A.1 for demeters are mod
make any chane configured PEED eS. figured in prot a “spare pool”drives will be aevent of a drive
G-SPEED eS carray changes mailed by settinttings” tab.
ch controller totegrity of the R
e G-SPEED en password x A.4 for details
e status of ailed SMART dat
G-SPEED eS nd monitored etails) dified on this nges on this
for optimal
tected mode ” (sometimes automatically e failure.
controller are and failures. ng up email
o RAID
S controller and email
s
ll connected ta.
A.1 Manage: A
1. Name: A
2. Type: Di
3. Capacity
4. Cache P
for RAIDappendix
5. OS Namdisplay in
6. Status: DNormaCriticaInitialRebui
Array
Array name (as
splays RAID lev
y: you guessed
Policy: DisplayD protected ax A.1.7.7
me: Controllern Disk Utility.
Displays currenal: All OK al: Drive failurelizing: Buildingilding: Parity d
shown in GUI
vel of array.
it… capacity of
s current writearrays. For m
r assigned na
nt status of arra
e has occurred g RAID 1, 5 or ata being recon
Page
only).
f the array.
e cache policy more info see
ame that will
ay.
10 array nstructed
e 18
G-SPE
7.
EED eS INSTA
Maintenanceoptions for cuon RAID level
RAID 0
7.1 Delete: D
WARNTHE A
7.2 Unplugcontroller. Bsystem beforto be unplugalarm.
NOTE: recommdisconne
7.3 Rename
ALLATION G
e: Displays conurrent array. Thl of the array.
Deletes current
NING: THIS ARRAY AND AL
: This will disBe sure to une using this opgged from the
While the contmend shutting the ecting G-SPEED eS
: Renames arra
UIDE
figuration and he options diffe
t Array
OPERATION LL DATA ON I
sconnect the Anmount all volption. This enae system with
troller is “hot psystem down whe
S from the controlle
ay as displayed
maintenance er depending
WILL DELETT!!
Array from thumes from thables the arrayout causing a
pluggable,” we n connecting or er.
in the GUI.
TE
he he ys an
7.4 OCE/ORLOnline Cacapacity oG-SPEED eOnline RAthe RAID
7.5 Shows the
location an
“Devic
RAID 5
7.6 Verify: Ve 7.7 Change CRAID 5 arrays.
Write-bcached.but datfailure. Write-talways reads mappropr
LM: pacity Expansio
of an existing areS units are ad
AID Level Migralevel of an exis
e devices currend status.
ce_Controller
erifies the integ
Cache Policy: .
back: Data . This will resuta loss may o through: Dat passed directlymay still be comriate
on: It is possibrray when addidded to the systation: it is posssting array.
ently part of t
r#_Port#_Driv
grity of the RAID
This option is
written to thult in higher poccur in case
a written to ty to the disks. mpleted from t
Page
le to expand thtional tem. sible to change
the Array, their
ve#”
D set.
available for
he array is performance, of a power
the array is Subsequent the cache, if
e 19
he
r
G-SPE
8. C
C
EED eS INSTA
Create Array Click on “Create
ALLATION G
Array” and the
UIDE
e following will
appear.
8
8
8
8
8
8
8
8
.1 Array Type
.2 Array Namthe MAIN pa
.3 Initializatiocreation pro
Foregroucreation pcomplete. Backgroufor the creimmediate
NOTunti
.4 Cache Polic
a RAID 5 ar
Write-backwill result inoccur in caseWrite-throupassed direcstill be comp
.5 Select All:
.6 Available Dfor array cserial numbcapacity.
Location:
.7 Available D
new array.available.
.8 Create: Asarray creatio
e: select the RA
me: This is theage of the GUI.
on Method: Seocess.
und: All controlprocess and th
und: Minimal eation process e use.
TE: RAID protectiol initialization is co
cy: This optionrray.
: Data written tn higher perfore of a power faiugh: Data writctly to the diskleted from the
Simple method
Disks: Displaycreation, showiber, size of th
“Controller#
Disks: Enter t Default is
s expected, seon process.
AID level for new
name that wi
ets the priority
ller resources ahe array is not
controller reso and the array
n is not available mplete
n is available w
to the array is mance, but dailure. tten to the arraks. Subsequent cache, if appro
d to select all di
ys disks currening location, dhe disk and c
#/Port#/Drive
the desired caps the Maximu
electing this wi
Page
w array
ill be displayed
of the RAID
are used for tht available unt
ources are usey is available fo
hen creating
cached. This ata loss may
ay is always t reads may opriate
isks.
ntly available drive model, current free
e#”
pacity of the um capacity
ill begin the
e 20
d in
he til
ed or
G-SPE
9. Loco
Lo
10. Modis
11. Cacu
12. Madis
13. Rede
14. Be
EED eS INSTA
ocation: Showntroller.
ocation: “Contr
odel: Displayssks currently at
apacity: Displarrently attache
ax Free: Dispsks currently at
escan: Rescanevices attached
eeper Mute: M
NOTE: Beepedisconnected “Unplug” in th
ALLATION G
ws the location o
roller#/Port#/
s the drive mottached to the c
ays the advertied to the contro
lays the maximttached to the c
ns the eSATA .
Mutes audible be
er will sound when from the system w
he Array Maintenan
UIDE
of disks attache
/Drive#”
odel and serial controller.
sed capacity ooller.
mum free capacontroller.
bus to detect
eeper.
a drive fails or an awithout first selectinnce menu.
ed to the
number of
of the disks
acity of the
t any new
array is ng
(This page left inte
entionally blan
Page
nk)
e 21
G-SPE
Ap
EED eS INSTA
pendix A.4: S
ALLATION G
ettings
UIDE
1.
2.
3. 4.
5.
6.
7. 8.
9.
Auto Rebuildfeature. Whearray will autinserted. See
Audible Alar SAF-TE: This
Listening PoG-SPEED webnetwork users
Password: C
SMTP Settinfor email nothere.
Recipients: A
Add Recipienotification. S
InformationWarning: WaError: Error e Test: Sends a
HDD Temperof the hard email. Defaucan operate u
d: Enables oren enabled, a tomatically rebe Section 12 for
rm: Enables or
s feature is not
ort: The port b GUI. “Restrics to access the
Changes login p
ng: Email sertification. Ente
A list of current
ent: Add emSelect Event lev
: Informationaarning events aevents are sent
a test email to
rature Threshdrive temperault is 50°C, houp to 60°C.
r disables the critical RAID 5
build when a nr details.
r disables the a
currently suppo
used to conct to local acce GUI. Default i
password. Defau
rver informatioer your server
t email recipien
mail addressesvel to trigger a
l events are seare sent t
the new accoun
hold: Adjusts tture to triggeowever today’s
Page
auto-rebuild 5 or RAID 1 new drive is
udible alarm
orted.
nect to the ess” disables is Port 7402.
ult is 0000
on necessary information
nts.
s for email n email.
nt
nt
he threshold r a warning
s disk drives
e 22
G-SPEED eS INSTALLATION GUIDE
Page 23
APPENDIX B: RAID levels explained
RAID Level Description Advantage Disadvantage Ideal For…
0 Disk striping Offers the highest performance and a useable storage capacity of 100% of total available storage capacity
No fault tolerance - failure of one drive in the array results in complete data loss
Content creation applications requiring highest storage capacity
1 Mirroring Maximum level of data protection as identical data is written to multiple drives
Useable storage space is 50% of total available capacity
Applications in which data security is paramount
5 Disk striping with distributed parity
High read performance, medium write performance with data protection in case of a drive failure.
Useable storage capacity equals total capacity of all drives in the array less the capacity of one drive. For example, a 4x 1TB RAID 5 yields a useable capacity of 3 TB. Disk failure results in drop in performance
Content creation applications requiring data protection
10 Mirror of striped drive pairs
Higher performance than RAID 1 with same level of data protection.
Useable storage space is 50% of total available capacity
Content creation applications requiring data protection
JBOD Just-a-bunch-of-disks
Each drive can be accessed as an individual volume. Useable storage capacity is 100% of total available storage.
No fault tolerance Audio applications
APPENDIX C: Notes When the G-Tech web GUI is open dropped frames may occur in editing applications such as Final Cut Pro. We recommend not having the GUI open while working in these programs. It is recommended not to exceed the standard eSATA cable length of 1 meter (3 feet). Up to (4) G-SPEED eS storage units can be attached to the G-Tech RAID controller for up to 16TB of capacity and over 600 MB/sec of performance. Replacements / extra G-SPEED eS disk modules are available for purchase online at: www.g-technology.com/products/g-speed-es.cfm