Fy2006 Mfc Construction

24
Most Frequently Cited Serious Violations Construction – FY 2006

Transcript of Fy2006 Mfc Construction

Page 1: Fy2006 Mfc Construction

Most Frequently CitedSerious Violations

Construction – FY 2006

Page 2: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

2

1887

1733

1433

1321

1178

1079

1069

1022

1007

823

501(b)(13) - M

501(b)(1) - M

100(a) - E

451(g)(1) - L

503(a)(1) - M

453(b)(2)(v) - L

451(e)(1) - L

451(b)(1) - L

1053(b)(1) - X

21(b)(2) - C

Most Frequently Cited Serious Violationsin Construction – FY 2006

Fall hazards training program

Head protection

Scaffolds - Platform construction

Employee training programs

Aerial lifts – Body belt & lanyard

Scaffolds - Fall protection

Fall protection - Unprotected sides & edges

Fall protection – Residential construction 6’ or more

Portable ladders 3 feet above landing surface

Scaffolds - Access

Sta

nd

ard

& S

ub

part

- 1

92

6.

--

There were also 362 Section 5(a)(1) violations cited in construction SIC codes (1500 – 1799) during this period.

Page 3: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

3

823

714

630

223

85

21(b)(2)

20(b)(1)

20(b)(2)

25(a)

28(a)

Sta

nd

ard

- 1

92

6.

Subpart C - General Safety & Health(1926.20 - 35)

Employee training programs

Inspections by competent person

Initiate and maintain accident prevention programs

Personal protective equipment – Employer responsibility

Housekeeping

Page 4: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

4

Subpart D - Occupational Health & Environmental Controls

(1926.50 - 66)

58

42

30

29

28

62(d)(1)(i)

50(c)

62(d)(1)(iii)

62(d)(2)(v)(E)

62(d)(2)(v)(B)

Sta

nd

ard

- 1

92

6.

Lead – Representative personal sampling

Lead - Exposure assessment

First aid training

Lead – Interim personal protective clothing & equipment

Lead – Interim handwashing facilities

Page 5: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

5

Subpart E - Personal Protective & Life Saving Equipment

(1926.95 - 107)

1433

698

307

22

15

100(a)

102(a)(1)

95(a)

106(a)

102(a)(2)

Sta

nd

ard

- 1

92

6.

Head protection

Required eye & face protection – ANSI requirements

PPE - Provided, used & maintained

Eye & face protection

Life jackets/vests

Page 6: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

6

Subpart F - Fire Protection & Prevention(1926.150 - 159)

34

28

21

20

47150(c)(1)(i)

150(c)(1)(vi)

152(e)(4)

150(c)(1)(iv)

152(g)(11)

Sta

nd

ard

- 1

92

6. Extinguishers within 50 ft. of flammables/combustibles

2A fire extinguishers - Building area

Extinguishers on each floor

Extinguishers in each service/fueling area

Flammable/combustible liquids dispensing units – Protection from damage

Page 7: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

7

44

38

32

6

4

200(g)(2)

201(a)

200(g)(1)

200(a)

202

Sta

nd

ard

- 1

92

6.

Subpart G - Signs, Signals & Barricades(1926.200 - 203)

Traffic control signs/devices - Requirements

Barricades - Requirements

Flaggers – Proper signaling by & use of

Traffic signs at points of hazard

Visible signs & symbols

Page 8: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

8

Subpart H - Materials Handling, Storage, Use & Disposal

(1926.250 - 252)

26

20

19

16

12

251(a)(1)

252(a)

251(e)(8)(iii)

251(a)(6)

251(b)(1)

Sta

nd

ard

- 1

92

6.

Rigging equipment inspection & removal from service

Torn/cut synthetic web slings - Removal from service

Alloy steel chain slings - Identification

Exterior drop chutes

Rigging equipment – Daily inspections

Page 9: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

9

Subpart I - Tools: Hand & Power(1926.300 - 307)

82

75

46

46

37

304(f)

300(b)(1)

300(b)(2)

304(i)(1)

304(h)(1)

Sta

nd

ard

- 1

92

6.

Woodworking tools - ANSI requirements

Guarding of rotating/moving parts

Tools designed for guards - Guards in place

Guarding of ripsaws

Guarding of circular crosscut table saws

Page 10: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

10

Subpart J - Welding & Cutting(1926.350 -354)

92

76

30

19

16

350(a)(9)

350(a)(10)

350(a)(1)

350(h)

350(a)(7)

Sta

nd

ard

- 1

92

6.

Cylinders secured upright

Oxygen and fuel gas regulators/gauges in working order

Oxygen cylinder storage

Valve protection caps

Use of device to keep cylinders steady while in use

Page 11: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

11

Subpart K - Electrical(1926.400 - 449)

397

340

203

148

139

404(f)(6)

404(b)(1)(i)

403(b)(2)

404(b)(1)(ii)

405(g)(2)(iv)

Sta

nd

ard

- 1

92

6.

Ground fault protection

Grounding path

Equipment installation & use

Ground-fault circuit interrupters

Flexible cords – Strain relief

Page 12: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

12

Subpart L - Scaffolds(1926.450 - 454)

1321

1079

1069

1022

763

451(g)(1)

453(b)(2)(v)

451(e)(1)

451(b)(1)

454(a)

Sta

nd

ard

- 1

92

6.

Scaffolds above 10 ft. - Fall protection

Scaffold access

Scaffold platform construction

Aerial lifts - Body belt & lanyard

Training for employees using scaffolds

Page 13: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

13

1887

1733

1178

510

374

501(b)(13)

501(b)(1)

503(a)(1)

501(b)(10)

501(b)(11)

Sta

nd

ard

- 1

92

6.

Subpart M - Fall Protection(1926.500 - 503)

Fall protection - Residential construction 6’ or more

Fall hazards training program

Fall protection - Unprotected sides & edges

Fall protection - Roofing work on low-slope roofs

Fall protection – Steep roofs

Page 14: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

14

21

21

20

18

16

16

550(a)(6)

550(a)(9)

550(a)(1)

550(b)(2)

550(a)(15)(i)

550(a)(19)

Sta

nd

ard

- 19

26.

Subpart N - Cranes, Derricks, Hoists, Elevators & Conveyors

(1926.550 - 556)

Cranes and derricks – Manufacturers’ specifications

Annual inspection of hoisting machinery

Clearances between power lines & equipment

Swing radius at rear of crane barricaded

Employees kept clear of loads

ANSI Requirements

Page 15: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

15

Subpart O - Motor Vehicles, Mechanized Equipment, & Marine Operations

(1926.600 - 606)

73

48

42

34

29

602(c)(1)(vi)

602(a)(9)(ii)

602(c)(1)(viii)(A)

602(a)(9)(i)

602(c)(1)(ii)

Sta

nd

ard

- 1

92

6.

Earthmoving/compacting equipment - Reverse signal alarm

Bi-directional machines - Horn

Manufacturers’ written approval for modifications

Lifting/hauling equipment - Use of safety platform

Industrial trucks - ANSI B56.1-1969

Page 16: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

16

Subpart P - Excavations(1926.650 - 652)

95

336

352

424

817652(a)(1)

651(c)(2)

651(k)(1)

651(j)(2)

651(k)(2)

Sta

nd

ard

- 1

92

6.

Employee protection in excavations - Protective system use

Inspections by competent person

Protection from falling/rolling materials/equipment

Egress from trench excavations

Competent person inspection - Employees removed from hazard

Page 17: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

17

Subpart Q - Concrete & Masonry Construction(1926.700 - 706)

258

21

12

11

701(b)

706(b)

703(a)(1)

706(a)(1)

Sta

nd

ard

- 1

92

6.

Reinforcing steel - Guarding

Masonry walls - Bracing

Masonry walls – Limited access zone prior to start

Formwork – Capable of supporting loads

Page 18: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

18

Subpart R – Steel Erection(1926.750 - 761)

218

65

25

15

10

760(a)(1)

761(b)

760(b)(3)

760(b)(1)

760(a)(2)

Sta

nd

ard

- 1

92

6.

Protection from fall hazards

Perimeter safety cables

Fall protection for connectors – 15’ to 30’

Fall hazard training

Fall protection for connectors – More than 2 stories or 30’

Page 19: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

19

57

11

10

7

6

850(a)

856(b)

850(d)

852(a)

851(b)

Sta

nd

ard

- 1

92

6.

Subpart T - Demolition(1926.850 - 860)

Engineering survey - Prior to operations

Chutes – No material dropped outside structure unless protected

Floor openings – Curbs or stop-logs

Stairs, passageways, ladders, etc. – Inspected and maintained

Relocation/protection of utilities

Page 20: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

20

Subpart X - Ladders(1926.1050 - 1060)

Stairrails & handrails

1007

310

294

221

220

1053(b)(1)

1052(c)(1)

1060(a)

1053(b)(4)

1051(a)

Sta

nd

ard

- 1

92

6.

Portable ladders 3 feet above landing surface

Stairway/ladder when 19” or more break in elevation

Training program

Appropriate use of ladders

Page 21: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

21

Subpart Z - Toxic & Hazardous Substances(1926.1100 - 1152)

39

33

30

28

19

1101(f)(2)(i)

1101(k)(9)(i)

1101(i)(1)

1101(e)(1)

1101(f)(1)(i)Sta

nd

ard

- 1

92

6.

Asbestos - Exposure assessment by competent person

Asbestos - Class I, II, & III asbestos work in regulated areas

Asbestos – Protective clothing

Asbestos - Training program

Asbestos - Monitoring

Page 22: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

22

64

53

41

28

23

134(c)(1)

134(e)(1)

134(d)(1)(iii)

134(f)(1)

134(k)(1)

Respiratory Protection (1910.134)Cited in Construction SIC Codes

Medical evaluation to determine employee’s ability to use respirator

Employee demonstration of knowledge of respirator

Evaluation of respiratory hazards

Qualitative or quantitative fit testing

Written respiratory protection program

Sta

nd

ard

: 19

10.

Page 23: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

23

89

23

11

8

178(l)(1)(i)

178(l)(1)(ii)

178(l)(6)

178(l)(4)(iii)

Powered Industrial TruckOperator Training [1910.178(l)]Cited in Construction SIC Codes

Training prior to truck operation

Operator evaluation every 3 years

Operator certification

Sta

nd

ard

: 19

10.

Operator competency

Page 24: Fy2006 Mfc Construction

Number of Serious Violations - FY 2006

24

Hazard Communication (1910.1200)Cited in Construction SIC Codes

196

91

63

57

49

1200(e)(1)

1200(h)(1)

1200(g)(1)

1200(h)

1200(g)(8)

Written program

Information & training

Material Safety Data Sheets readily accessible

Training initially & for new hazards

Material Safety Data Sheets

Sta

nd

ard

: 19

10.